DS-PDMC-EG2-WB/WE Wireless Magnet Detector

2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved. About this Manual The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to rmware updates or other reasons. Please nd the latest version of this Manual at the Hikvision website (https://www.hikvision.com/). Please use this Manual with the guidance and assistance of professionals trained in supporting the Product.

and other Hikvision's trademarks and logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned are the properties of their respective owners.

Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED AS IS AND WITH ALL FAULTS AND ERRORS. HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.

1 The sensor can detect the door or window opening. When the door or window is open, an alarm will be triggered and it will be sent to the alarm center or mobile client via security control panel. Door Magnetic Sensor Alarm: When the distance between the sensor and the magnetic stick is longer than 3 cm, an alarm will be triggered. The indicator will ash once. Tamper Alarm: When removing the sensor, an alarm will be triggered.

Introduction

Appearance2

This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014/30/EU, RE Directive 2014/53/EU, the RoHS Directive 2011/65/EU.

replacement of a battery with an incorrect type that can defeat a safeguard (for example, in the case of some lithium battery types); disposal of a battery into re or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion; leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of ammable liquid or gas; and a battery subjected to extremely low air pressure that may result in an explosion or the leakage of ammable liquid or gas

2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info

2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specic battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see:www.recy- clethis.info

CAUTION

RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. REPLACEMENT OF A BATTERY WITH AN INCORRECT TYPE THAT CAN DEFEAT A SAFEGUARD.

CAUTION

CHEMICAL BURNING DANGER DO NOT SWALLOW THE BATTERY KEEP NEW AND USED BATTERIES AWAY FROM THE CHILDREN.

IF YOU THINK BATTERIES MIGHT HAVE BEEN SWALLOWED OR PLACED INSIDE ANY PART OF THE BODY, SEEK IMMEDIATE MEDICAL ATTENTION.

CAUTION

DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUC- TIONS AND LOCAL REGULATION.

EN 50131-1:2006+A2:2017 EN 50131-2-6:2008 EN 50131-5-3:2017

3

1 2

4

5

6

7

Indicator Alarm Detection: Red LED ashes. Detector Formatted: Red LED ashes 3 times.

3

4 TAMPER Button Tampering Alarm: If the detector is disassembled, an alarm will be triggered. Formatting: Restore the device to default settings.

Power Switch

External Input

Battery

2

5

6

6

Positioning Line

1 Magnetic Stick

1 Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China

Security Grade(SG) 2 Environmental Class(EC) II Certied by Telecation

Dig the groove to disassemble the device. Remove the front and rear panel. Turn the power switch to ON to power on the device. Note: Do not disassemble the device with sharps.

3 Power On

4 Enrollment

1 Enroll the Peripheral Locally

2 Enroll the Peripheral with QR and serial No.

1. Log in to the APP Store, download and install the App. 2. Power on the security control panel. 3. Log in the APP and tap the icon "+" . Scan the QR code or input the control panel serial No. to add the control panel.

1. In the APP, tap the "Enrollment Mode" button on the control panel page to make the control panel enter the enrollment status. 2. Power on the peripheral, and it will be automatically enrolled to the control panel.

1. In the APP, tap the icon "+"and scan the QR code or serial No. on the peripheral. 2. Power on the peripheral, and it will be automatically enrolled to the control panel.

CAUTION

IF THE BATTERY COMPARTMENT DOES NOT CLOSE SECURELY, STOP USING THE PRODUCT AND KEEP IT AWAY FROM CHILDREN.

xxxx

Device

5 Test The contact starts test automatically after being enrolled to the AX PRO. The LED turn red. Separate the contact, and make a gap between the sensor and stick. while the LED turns green, the alarm is triggered by this gap . Adjust the installation position of the contact to get a satised alarm gap.

The alarm will be triggered while the gap between the sensor and magnetic stick is bigger than that shows in the table. The LED keeps blue for 2 s.

Magnet Detection Performance Table

2 Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China

Break 11 10 Make 10 8 Break 11 10 Make 10 9 Break 28 15 Make 24 12 Break 31 22 Make 27 20 Break 45 15 Make 42 13

On non-ferromagnetic material surface

On ferromagnetic material surface

X-

Y

Z+

Axes of Operation

Event

X+

Z-

1. Check Signal Strength Enter the signal checking mode by operating on the control panel. Trigger the detector. Solid Green for 3 s - Strong Signal Solid Orange for 3 s - Medium Signal Solid Red for 3 s - Weak Signal Red light ashes for 3S - Lost Signal

2. Install the Detector Dig the groove to disassemble the device. Method 1: Secure the rear panel to the wall with two screws. Method 2: Paste rear panel on the wall with the sponge tape. Note: To make the TAMPER work properly, the thickness of the sponge tape should be no more than 1mm. Installing with sponge tape is non EN compliant. Sedure the front and the rear panel. Note: Secure the front and rear panel with screw for EN compliance. You should install the sensor and the magnetic stick at the door or windows edge. Make sure they are aligned with the door or windows edge.

6 Installation

3 min

Z

X

Y

X

Signal Strength Test

Method 1. Align the Positioning Line

Method 2. (optional)route the cable through cable hole if external inputs required.

3 Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China

7

9

Functions You can add two external inputs (each input can be set as NO\NC\TAMPER\Pulse) via the AX PRO client. While Any of the two inputs generates an alarm event, the contact reports the alarm to the AX PRO. The LED keeps blue for 2 s.

4 Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China

Set Up with App

8

Function

Zone Type

Stay Arm Bypass

Chime

Enable Silent Zone

Slide to green to enable the chime.

Slide to green to make the zone keep silent while alarm is triggered.

Select the zone type of the detector.

Description

You can view the device status including temperature, signal intensity,battery level, lid, magnetic contact, external contact, etc.,on the device page. Tap the button to enter the settings page.

Double Knock Slide to green to make the zone alarm with double knock.

Cross Zone

Link Camera

Magnetic Contact

External Contact1

Slide to green to bypass the zone from stay arming.

If the alarm triggered in both of the linked zones within the set time, two alarm messages will be reported.

LED Turn On/O the LED.

Polling Rate Set the interval of heartbeat.

Signal Strength Test Enter the test mode, and view the LED indication.

Detection Zone Test Enter the test mode, separate the contact, and start the test with Magnet Detection Performance Table.

Zone Bypass By pass the zone.

Link with a camera for intruder verication.

Slide to green to enable magnetic contact(Not allowed under EN).

Slide to green to enable the wired external contact 1.

External Contact2 Slide to green to enable the wired external contact 2.

Formatting 1. Remove the battery. 2. Hold the TAMPER button and power the detector on at the same time. The red LED ashes 3 time when the formatting is completed.

Disallowed eld adjustable settings: None

11 Specication

10 Operation Caution and Device Maintenance - All the electronic operation should be strictly compliance with the electrical safety regulations, re prevention regulations and other related regulations in your local region. - Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage). - Please make sure that the power has been disconnected before you wire, install or dismantle the device. - If smoke, odors or noise rise from the device, turn o the power at once and unplug the power cable, and then please contact the service center. - Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage). - Do not place the device in extremely hot (refer to the specication of the device for the detailed operation temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation. - The device for indoor use shall be kept from rain and moisture. Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is forbidden (ignorance can cause re danger). - Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfunction however), and aecting the endurance of sensor at the same time. - Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or equivalent type only. Dispose of used batteries according to the instructions provided by the battery manufacturer. - Do not expose the device to the corrosive gas. Otherwise the equipment damage may occur. - Do not expose the device to the explosive situation.

5 Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China

Model DS-PDMC-EG2-WB/WE

Detection Performance Detection Method Opening Contact

Detection Gap 43mm Max

Feature

Digital Processing Support

Tamper Protection Front,Rear

Environment Temperature Indicator Support

Signal Strength Indicator Support

Interface

Alarm Input Normally Closed,Normally Open,Impulse Count

Power Switch Power Up Enrolling

LED Indicator Blue (Alarm)

Transmission

Transmission Technology Tri-X Wireless

Transmission Method Two-Way RF Wireless

Transmission Frequency 433/868MHz

Transmission Security AES-128 Encryption

Transmission Range(Free Space) 1.2Km(433MHz)/ 1.6Km(868MHz)

Frequency Hopping Support

Enrolling Method Power up,Remote ID,QR Code

Electrical Characteristics

Power Supply Battery Powered

Battery Type CR123A x 1 (included), 3V/1600mAh

Typical Voltage 3V

Consumption Max. current: 41.57 mA

Quiescent current: 27.5A

Low Battery Level 2.45 V

Standard Battery Life 5 Years

General

Operation Temperature -10 C to 55 C (14 F to 131 F)

Manualsnet FAQs

If you want to find out how the DS-PDMC-EG2-WB Hikvision works, you can view and download the Hikvision DS-PDMC-EG2-WB Detector User's Manual on the Manualsnet website.

Yes, we have the User's Manual for Hikvision DS-PDMC-EG2-WB as well as other Hikvision manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Manual should include all the details that are needed to use a Hikvision DS-PDMC-EG2-WB. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Hikvision DS-PDMC-EG2-WB Detector User's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Hikvision DS-PDMC-EG2-WB Detector User's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Hikvision DS-PDMC-EG2-WB Detector User's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Hikvision DS-PDMC-EG2-WB Detector User's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Hikvision DS-PDMC-EG2-WB Detector User's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.