Summary of Content for Hikvision DS-2TE127-G4A Calibrator User's Manual PDF

Symbol Convention

The symbols that may be found in this document are defined as follows.

Symbol Description

Provides additional information to emphasize or supplement

important points of the main text.

Indicates a potentially hazardous situation, which if not avoided, could result in equipment damage, data loss, performance

degradation, or unexpected results.

Indicates a hazard with a high level of risk, which if not avoided, will result in death or serious injury.

Safety Instructions

Input voltage should be from 100 VAC to 240 VAC, 50 Hz/60 Hz. Check if power or accessory is damaged before use.

Please use the supplied cable.

DO NOT charge the device or operate the device with wet hands. DO NOT touch the radiation surface to avoid the scratch to influence the accuracy of

temperature measurement.

The working status of black body has been tested and debugged. DO NOT change the parameters on the temperature control panel, or it may lead to device exception.

DO NOT aim the device at sun, and protect it from wind during on-site calibration.

Keep the camera away from liquid to avoid damage or danger.

DO NOT cover the ventilation holes while in use.

COMPLIANCE NOTICE: The thermal series products might be subject to export controls in

various countries or regions, including without limitation, the United States, European Union,

United Kingdom and/or other member countries of the Wassenaar Arrangement. Please consult

your professional legal or compliance expert or local government authorities for any necessary

export license requirements if you intend to transfer, export, re-export the thermal series

products between different countries.

2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.

About this Manual

The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information

contained in the Manual is subject to change, without notice, due to firmware updates or other

reasons. Please find the latest version of this Manual at the Hikvision website (http://www.hikvision.com).

Please use this Manual with the guidance and assistance of professionals trained in supporting

the Product.

Trademarks Acknowledgement

and other Hikvisions trademarks and logos are the properties of Hikvision in

various jurisdictions.

Other trademarks and logos mentioned are the properties of their respective owners.

LEGAL DISCLAIMER

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT

DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED AS IS AND

WITH ALL FAULTS AND ERRORS. HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS

FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO

EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS,

BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF

DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE

PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR

LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY RISKS,

AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY

LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY

TECHNICAL SUPPORT IF REQUIRED.

YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW.

ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT

INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY

RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE

DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT

RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF

HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER

PREVAILS.

1. Function It is specially designed for calibrating temperature detection thermal device and thermal

inspection device in various sizes.

Excellent temperature uniformity, accuracy, and stability of calibration.

Adopts intelligent temperature controller and has high temperature control accuracy. Good performance and favorable price compared with similar products.

This device is not for medical use.

2. Appearance and Panel Introduction

Figure 1-1 Device Appearance

Measuring Temperature PV

Setting Temperature

(SV)

Control Panel

Figure 1-2 Temperature Controller

Black Body

User Manual

3. Technical Data

Parameter Value

Temperature Range Adjustable: environment temperature+5 C (9 F), up

to 50C (122 F)

Effective Radiating Area 70 mm (2.76)

Temperature Resolution 0.1 C (0.18 F)

Temperature Accuracy 0.1 C (0.18 F)

Temperature Stability 0.1 C/h

Effective Emissivity 0.97 0.02

Power Consumption 20 W

Environment Temperature 0 C to 35C (32 F to 95 F)

Weight 1.85 Kg (4.08 lb)

Dimension 120 mm 176.6 mm 119.6 mm (4.72 6.95 4.71)

Power 100 VAC to 240 VAC

Mounting Mounting on a plane desk

or a tripod with 1/4-20UNC Interface

or a ceiling mount bracket with 1/4-20UNC Interface

4. Mounting

1. Check the power supply. The working voltage should be 100 VAC-240 VAC, 35 W.

2. Check if the desk is horizontal.

3. Mount the device on the desk or a tripod in front of the thermal camera firmly. Make

sure that the front of black body can show in the live view of thermal camera

completely, and outside the temperature measurement area.

4. Switch on the device, and the power indicator is on. The factory default setting

temperature is 40 C.

5. Operation

1. Connect the black body with a 10 A socket via the power cable.

2. Switch on the device, and the power indicator is on. The factory default setting

temperature is 40 C.

3. Wait for 30 minutes after switching on device. You can calibrate the thermal camera

when the temperature is stable at 40 C.

4. Switch off the black body and store it after use.

6. Maintenance

1. The black body should be managed and maintained by professional person, and

maintenance and usage should be recorded.

2. DO NOT use the device in an environment with oil or chemical air.

3. To ensure the temperature accuracy, place the device firmly in the environment with

stable temperature. The recommended using environment temperature is 10 C to

25 C (50 F to 77 F)

4. Power off the device before mounting or removing it.

5. Clean the surface of device with a neutral detergent. Clean the dust on the black body

with a soft brush.

6. Store the device in the packing box after use to prevent dust. Make sure the

environment temperature is suitable.

Manualsnet FAQs

If you want to find out how the DS-2TE127-G4A Hikvision works, you can view and download the Hikvision DS-2TE127-G4A Calibrator User's Manual on the Manualsnet website.

Yes, we have the User's Manual for Hikvision DS-2TE127-G4A as well as other Hikvision manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Manual should include all the details that are needed to use a Hikvision DS-2TE127-G4A. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Hikvision DS-2TE127-G4A Calibrator User's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Hikvision DS-2TE127-G4A Calibrator User's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Hikvision DS-2TE127-G4A Calibrator User's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Hikvision DS-2TE127-G4A Calibrator User's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Hikvision DS-2TE127-G4A Calibrator User's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.