DS-K3B411SX Series Swing Barrier Quick Start Guide

Legal Information

2021 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.

About this Manual The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website ( https:// www.hikvision.com/ ). Please use this Manual with the guidance and assistance of professionals trained in supporting the Product.

Trademarks

and other Hikvision's trademarks and logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned are the properties of their respective owners.

Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED "AS IS" AND "WITH ALL FAULTS AND ERRORS". HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE

DS-K3B411SX Series Swing Barrier Quick Start Guide

i

DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER PREVAILS.

Data Protection During the use of device, personal data will be collected, stored and processed. To protect data, the development of Hikvision devices incorporates privacy by design principles. For example, for device with facial recognition features, biometrics data is stored in your device with encryption method; for fingerprint device, only fingerprint template will be saved, which is impossible to reconstruct a fingerprint image. As data controller, you are advised to collect, store, process and transfer data in accordance with the applicable data protection laws and regulations, including without limitation, conducting security controls to safeguard personal data, such as, implementing reasonable administrative and physical security controls, conduct periodic reviews and assessments of the effectiveness of your security controls.

DS-K3B411SX Series Swing Barrier Quick Start Guide

ii

Regulatory Information

FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help FCC Conditions This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation.

EU Conformity Statement

This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed

DS-K3B411SX Series Swing Barrier Quick Start Guide

iii

under the EMC Directive 2014/30/EU, LVD Directive 2014/35/EU, the RoHS Directive 2011/65/EU

2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info

2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see:www.recyclethis.info

Industry Canada ICES-003 Compliance This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements.

DS-K3B411SX Series Swing Barrier Quick Start Guide

iv

Safety Instruction

These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Dangers and Cautions: Dangers: Neglecting any of the warnings may cause serious injury or death. Cautions: Neglecting any of the cautions may cause injury or equipment damage.

Dangers: Follow these safeguards to prevent serious injury or death.

Cautions: Follow these precautions to prevent potential injury or material damage.

Danger: In the use of the product, you must be in strict compliance with the electrical safety regulations

of the nation and region. The equipment must be connected to an earthed mains socket-outlet. Shock hazard! Disconnect all power sources before maintenance. Do not touch the bare metal contacts of the inlets after the circuit breaker is turned off.

Electricity still exists. indicates hazardous live and the external wiring connected to the terminals requires installation by an instructed person.

Keep body parts away from fan blades. Disconnect the power source during servicing. Keep body parts away from motors. Disconnect the power source during servicing. To prevent possible hearing damage, do not listen at high volume levels for long periods. All the electronic operation should be strictly compliance with the electrical safety regulations, fire prevention regulations and other related regulations in your local region.

Do not connect several devices to one power adapter as adapter overload may cause over-heat or fire hazard.

Please make sure that the power has been disconnected before you wire, install or dismantle the device. If the top caps should be open and the device should be powered on for maintenance, make sure: 1. Power off the fan to prevent the operator from getting injured accidentally. 2. Do not touch bare high-voltage components. 3. Make sure the switchs wiring sequence is correct after maintenance.

Please make sure that the power has been disconnected before you wire, install or dismantle the device.

When the product is installed on wall or ceiling, the device shall be firmly fixed. If smoke, odors or noise rise from the device, turn off the power at once and unplug the power

cable, and then please contact the service center.

DS-K3B411SX Series Swing Barrier Quick Start Guide

v

Do not ingest battery, Chemical Burn Hazard. This product contains a coin/button cell battery. If the coin/button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death. Keep new and used batteries away from children. If the battery compartment does not close securely, stop using the product and keep it away from children. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention.

If the product does not work properly, please contact your dealer or the nearest service center. Never attempt to disassemble the device yourself. (We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.)

Cautions: The equipment shall not be exposed to dripping or splashing and that no objects filled with

liquids, such as vases, shall be placed on the equipment. Ensure correct wiring of the terminals for connection to an AC mains supply. The equipment has been designed, when required, modified for connection to an IT power distribution system.

+ identifies the positive terminal(s) of equipment which is used with, or generates direct current. + identifies the negative terminal(s) of equipment which is used with, or generates direct current.

No naked flame sources, such as lighted candles, should be placed on the equipment. This equipment is suitable for mounting on concrete or other non-combustible surface only. Install the equipment according to the instructions in this manual. To prevent injury, this equipment must be securely attached to the floor/wall in accordance with

the installation instructions. Stainless steel may be corroded in some circumstances. You need to clean and care the device by

using the stainless steel cleaner. It is suggested to clean the device every month. Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage).

Do not place the device in extremely hot (refer to the specification of the device for the detailed operating temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation.

The device cover for indoor use shall be kept from rain and moisture. Exposing the equipment to direct sun light, low ventilation or heat source such as heater or

radiator is forbidden (ignorance can cause fire danger). Do not aim the device at the sun or extra bright places. A blooming or smear may occur

otherwise (which is not a malfunction however), and affecting the endurance of sensor at the same time.

Please use the provided glove when open up the device cover, avoid direct contact with the device cover, because the acidic sweat of the fingers may erode the surface coating of the device cover.

Please use a soft and dry cloth when clean inside and outside surfaces of the device cover, do not use alkaline detergents.

DS-K3B411SX Series Swing Barrier Quick Start Guide

vi

Please keep all wrappers after unpack them for future use. In case of any failure occurred, you need to return the device to the factory with the original wrapper. Transportation without the original wrapper may result in damage on the device and lead to additional costs.

Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or equivalent type only. Dispose of used batteries according to the instructions provided by the battery manufacturer.

Biometric recognition products are not completely applicable to anti-spoofing environments. If you require a higher security level, use multiple authentication modes.

Do not stay in the lane when the device is rebooting. RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED

BATTERIES ACCORDING TO THE INSTRUCTIONS. SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY. The instructions shall require connection of the equipment protective earthing conductor to the installation protective earthing conductor.

DS-K3B411SX Series Swing Barrier Quick Start Guide

vii

Available Models

Product Name Model Type Example Description

Swing Barrier DS-K3B411SX-L DS-K3B411SX-L/M Left Pedestal

DS-K3B411SX-M DS-K3B411SX-M/M DS-K3B411SX-M/M 868

Middle Pedestal

DS-K3B411SX-R DS-K3B411SX-R/M DS-K3B411SX-R/M 868

Right Pedestal

DS-K3B411SX-LS DS-K3B411SX-LS/M Left Pedestal (No Barrier)

DS-K3B411SX-MS DS-K3B411SX-MS/M Middle Pedestal (Single Barrier)

Scan the QR code to get User Manual of Swing Barrier. Note that mobile data charges may apply if Wi-Fi is unavailable.

Figure 1-1 QR Code

DS-K3B411SX Series Swing Barrier Quick Start Guide

viii

Contents Chapter 1 Overview .................................................................................................................... 1

1.1 Introduction ........................................................................................................................... 1

1.2 Main Features ........................................................................................................................ 1

Chapter 2 System Wiring ............................................................................................................ 3

Chapter 3 Installation ................................................................................................................. 6

3.1 Disassemble Pedestals ........................................................................................................... 6

3.2 Install Pedestals ..................................................................................................................... 6

Chapter 4 General Wiring ......................................................................................................... 11

4.1 Components Introduction .................................................................................................... 11

4.2 Wiring Electric Supply .......................................................................................................... 12

4.3 Wire Interconnecting Cable ................................................................................................. 13

4.3.1 Pull Interconnecting Cable .......................................................................................... 15

4.4 Wire Network Switch (Optional) .......................................................................................... 19

4.5 Terminal Description ............................................................................................................ 21

4.5.1 Main Control Board Terminal Description ................................................................... 21

4.5.2 Sub Control Board Terminal Description ..................................................................... 22

4.5.3 BUS Terminal Description ............................................................................................ 23

4.5.4 Access Control Board Terminal Description ................................................................ 25

4.5.5 Access Control Board UART Description ..................................................................... 31

4.5.6 RS-485 Wiring ............................................................................................................. 36

4.5.7 RS-232 Wiring ............................................................................................................. 37

4.5.8 Barrier Control Wiring ................................................................................................. 38

4.5.9 Alarm Output Wiring ................................................................................................... 39

4.5.10 Exit Button Wiring ..................................................................................................... 39

Chapter 5 Device Settings ......................................................................................................... 40

5.1 Pair Keyfob (Optional) .......................................................................................................... 40

DS-K3B411SX Series Swing Barrier Quick Start Guide

ix

5.2 Initialize Device .................................................................................................................... 41

5.3 Switch Relay Output Mode (NO/NC) .................................................................................... 42

5.3.1 Barrier Control Relay Output Mode ............................................................................ 42

5.3.2 Alarm Relay Output Mode (NO/NC) ............................................................................ 44

Chapter 6 Activation ................................................................................................................. 47

6.1 Activate via SADP ................................................................................................................. 47

6.2 Activate Device via Client Software ...................................................................................... 48

Appendix A. DIP Switch Description .......................................................................................... 50

Appendix B. Event and Alarm Type ........................................................................................... 51

Appendix C. Table of Audio Index Related Content ................................................................... 52

Appendix D. Error Code Description .......................................................................................... 53

Appendix E. Communication Matrix and Device Command ....................................................... 55

DS-K3B411SX Series Swing Barrier Quick Start Guide

x

Chapter 1 Overview

1.1 Introduction

Figure 1-1 Appearance

The swing barrier is designed to detect unauthorized entrance or exit. By adopting the swing barrier integratedly with the access control system, personnel should authenticate to pass through the lane via swiping IC or ID card, scanning QR code, etc. It is widely used in attractions, stadiums, construction sites, residences, etc.

1.2 Main Features 32-bit high-speed processor TCP/IP network communication and network speed adaptive

The communication data is specially encrypted to relieve the concern of privacy leak Permissions validation and anti-tailgating Remaining open/closed mode selectable Bidirectional (Entering/Exiting) lane

The barrier opening and closing speed can be configured according to the visitor flow The barrier will be locked or stop working when people are nipped Anti-forced-accessing

The barrier will be locked automatically without open-barrier signal. Self-detection, Self-diagnostics, and automatic alarm Audible and visual alarm will be triggered when detecting intrusion, tailgating, reverse passing,

and climbing over barrier IP conflict detection Remote control and management Online/offline operation LED indicates the entrance/exit and passing status

DS-K3B411SX Series Swing Barrier Quick Start Guide

1

Barrier is in open status when powered down; If the device is installed with supercapacitor, the barrier remains open when powered down

Fire alarm passing When the fire alarm is triggered, the barrier will be open automatically for emergency evacuation

Valid passing duration settings System will cancel the passing permission if a person does not pass through the lane within the valid passing duration

Opens/Closes barrier according to the schedule template

DS-K3B411SX Series Swing Barrier Quick Start Guide

2

Chapter 2 System Wiring

The preparation before installation and general wiring.

Steps 1. Draw a central line on the installation surface of the left or right pedestal. 2. Draw other parallel lines for installing the other pedestals.

Note The distance between the nearest two line is L+200 mm. L represents the lane width.

3. Slot on the installation surface and dig installation holes according to the hole position diagram.

Figure 2-1 Hole Position Diagram 4. Bury cables. Each lane buries 1 network cable and 1 high voltage cable. For details, see the

system wiring diagram below.

DS-K3B411SX Series Swing Barrier Quick Start Guide

3

Figure 2-2 System Wiring Diagram (General Wiring)

Note The supplied interconnecting cable length is 3.75 m. If you need a longer one, you can buy a

new accessory. The suggested inner diameter of the low voltage conduit is larger than 30 mm. If you want to bury both of the AC power cord and the low voltage cable at the entrance, the

two cables should be in separated conduits to avoid interference. If more peripherals are required to connect, you should increase the conduit diameter or bury

another conduit for the external cables. The external AC power cord should be double-insulated. The network cable must be CAT5e or the network cable has better performance. And the

suggested network cable length should be less than 100 m.

DS-K3B411SX Series Swing Barrier Quick Start Guide

4

Figure 2-3 Wire Face Recognition Terminal

Note The face recognition terminal installed on the left pedestal will gain power from the sub

switch, which should connect to high voltage. The suggested inner diameter of the low voltage conduit is larger than 30 mm. The supplied interconnecting cable length is 3.75 m. If you need a longer one, you can extend

the cable by yourself. If you want to bury both of the AC power cord and the low voltage cable at the entrance, the

two cables should be in separated conduits to avoid interference. If more peripherals are required to connect, you should increase the conduit diameter or bury

another conduit for the external cables. The external AC power cord should be double-insulated. The network cable must be CAT5e or the network cable has better performance. And the

suggested network cable length should be less than 100 m.

DS-K3B411SX Series Swing Barrier Quick Start Guide

5

Chapter 3 Installation

3.1 Disassemble Pedestals Before installation, you should use the key to open the pedestals. View the pictures below to find the lock holes.

Figure 3-1 Lock Holes

3.2 Install Pedestals Before You Start Prepare for the installation tools, check the device and the accessories, and clear the installation base.

DS-K3B411SX Series Swing Barrier Quick Start Guide

6

Steps

Note The device should be installed on the concrete surface or other non-flammable surfaces. In order to prevent stainless steel from rusting due to dirt during the construction process, it is

recommended to tear off the protective film after the device is installed. There may be residual glue at the film cutting position, and it is recommended to wipe the film with WD-40 protective liquid after tearing the film.

No face recognition terminal installed: If the installation area is too close to the wall, make sure the distance between the pedestal and the wall should be more than 20 mm, or the surface may be scratched.

Figure 3-2 Installation Distance (Without Face Recognition Terminal) Face recognition terminal installed: If the installation area is too close to the wall, make sure the

distance between the pedestal and the wall should be more than 20 mm, or the surface may be scratched.

DS-K3B411SX Series Swing Barrier Quick Start Guide

7

Figure 3-3 Installation Distance (With Face Recognition Terminal) The dimension is as follows.

Figure 3-4 Double-Barrier Dimension

DS-K3B411SX Series Swing Barrier Quick Start Guide

8

Figure 3-5 Single-Barrier Dimension

1. Prepare for the installation tools, check the components, and prepare for the installation base. 2. Drill holes on the ground according to the installation holes on the pedestals and insert the

expansion sleeves. 3. Seal the bottom of the turnstile to avoid water from entering. 4. According to the entrance and exit marks on the pedestals, move the pedestals to the

corresponded positions.

Note Make sure the installation holes on the pedestals and the base are aligned with each other.

5. Secure the pedestals with expansion bolts.

Note Do not immerse the pedestal in the water. In special circumstances, the immersed height

should be no more than 150 mm. The installation footprint is as follows:

DS-K3B411SX Series Swing Barrier Quick Start Guide

9

Figure 3-6 Installation Footprint

DS-K3B411SX Series Swing Barrier Quick Start Guide

10

Chapter 4 General Wiring

4.1 Components Introduction By default, basic components of the turnstile are connected well. The pedestals can communicate by wiring the interconnecting cables. And the turnstile supports wiring the AC electric supply for the whole system's power supply.

Note The voltage fluctuation of the electric supply is between 85 VAC and 264 VAC, 50 to 60 Hz.

The picture displayed below describes each component's position on the turnstile.

Note The diagram is for reference only.

Figure 4-1 Components Diagram 1

DS-K3B411SX Series Swing Barrier Quick Start Guide

11

Note The reinstalled supercapacitor needs to be powered on for at least 3 minutes before it can work normally.

The picture displayed below describes the IR adapter and the IR sending/receiving board and their corresponding number on the pedestal.

Figure 4-2 Components 2

Note If the turnstile contains two lanes, standing at the entrance position, the IR boards on the left pedestal are the IR sending boards. The IR boards on the right pedestal are the IR receiving boards. The IR boards on the left side of the middle pedestal are the IR receiving boards, while the IR boards on the right side of the middle pedestal are the IR sending boards.

4.2 Wiring Electric Supply Wire electric supply with the switch in the pedestal. Terminal L and terminal N are on the switch, while terminal PE should connect to a ground wire (yellow and green wire).

Before wiring, open the protective cover outside the switch.

DS-K3B411SX Series Swing Barrier Quick Start Guide

12

Note The cable bare part should be no more than 8 mm. It is suggested that you can immerse the

bare part into the liquid tin. If possible, wear an insulation cap at the end of the bare cable. Make sure there's no bare copper or cable after the wiring.

The Terminal L and the Terminal N cannot be wired reversely. Do not wire the input and output terminal reversely.

To avoid people injury and device damage, when testing, the ground resistance of the equipotential points should not be larger than 2 .

4.3 Wire Interconnecting Cable You should use interconnecting cables to connect the main lane board and the sub lane board for components communication.

The picture displayed below describes the cable hole's position on the pedestals.

DS-K3B411SX Series Swing Barrier Quick Start Guide

13

Figure 4-3 Cable Hole of Interconnecting Cable

Follow the instructions below to connect the interconnecting cable.

DS-K3B411SX Series Swing Barrier Quick Start Guide

14

Figure 4-4 Connect Interconnecting Cable

4.3.1 Pull Interconnecting Cable

Steps 1. Use the key to unlock the upper lock of the pedestals and remove the top cover.

DS-K3B411SX Series Swing Barrier Quick Start Guide

15

Figure 4-5 Dissemble Top Cover 2. Dissemble the card presenting board.

DS-K3B411SX Series Swing Barrier Quick Start Guide

16

Figure 4-6 Dissemble Card Presenting Board 3. Dissemble the card reader module.

DS-K3B411SX Series Swing Barrier Quick Start Guide

17

Figure 4-7 Dissemble Card Reader Module 4. Pull the interconnecting cable out from the bottom up with pull-out tool, and other wiring

operations can be performed.

Note Interconnecting cable includes a network cable and a power supply cable of 24 V.

DS-K3B411SX Series Swing Barrier Quick Start Guide

18

Figure 4-8 Pull out Interconnecting Cable

4.4 Wire Network Switch (Optional) Connect the network cable and the network switch.

Steps

Note The device do not support the PoE network switch. Connecting with the PoE network switch may damage the control board.

1. Use the key to open the top cover of the pedestal.

DS-K3B411SX Series Swing Barrier Quick Start Guide

19

Figure 4-9 Open Top Cover 2. Attach the network switch to the position shown in the figure with adhesive.

DS-K3B411SX Series Swing Barrier Quick Start Guide

20

Figure 4-10 Network Switch Position 3. Lead out the 12 V power supply from the power switch and connect it to the switch power

interface. 4. Connect the network cable according to your actual needs.

4.5 Terminal Description The lane controller contains main lane controller and sub lane controller, which controls the IR beams, motor, and other components' work.

4.5.1 Main Control Board Terminal Description

The main lane control board contains power input, BUS interface, interconnecting interface, supercapacitor interface, IR interface, barrier position control board interface and motor drive interface.

The picture displayed below is the main control board diagram.

DS-K3B411SX Series Swing Barrier Quick Start Guide

21

Figure 4-11 Main Control Board Terminal

4.5.2 Sub Control Board Terminal Description

The sub lane control board contains power input, BUS interface, interconnecting interface, supercapacitor interface, IR interface, barrier position control board interface and motor drive interface.

The picture displayed below is the sub control board diagram.

Figure 4-12 Sub Control Board Terminal

DS-K3B411SX Series Swing Barrier Quick Start Guide

22

4.5.3 BUS Terminal Description

You can connect the lane controller light board, fan, TAMPER, lane control board, card reader, face recognition terminal, QR code scanner, etc. via the BUS terminal.

Note Part of the wiring has been completed at the factory, please connect according to actual needs. If you have to connect card reader, face recognition module, and fingerprint module at the same time, you should connect the card reader and the face recognition module to a same RS-485 interface, while the fingerprint module can connect to an RS-485/RS-232 interface with the jumper cap.

Table 4-1 BUS Terminal in Main Lane Controller

Terminal Name Description

Lane Controller Light Board 1 Connects lane controller light board 1

Lane Controller Light Board 2 Connects lane controller light board 2

Fan 1 Connects fan 1

Fan 2 Connects fan 2

TAMPER Connects TAMPER

Lane Controller Board Connect sub lane controller board

5 V Reserved

Port 1

Note External card reader or face recognition terminal is recommended to access. If both should be connected, you should configure the address code for both of the devices.

Red 12 V: connects 12 VDC power supply terminal

Yellow 485A/232A+: card reader RS-485A+/RS-232A+ access terminal

Blue 485A/232A-: card reader RS-485A-/RS-232A- access terminal

Black GND: grounding

Table 4-2 BUS Terminal in Sub Lane Controller (Left Pedestal)

Terminal Name Description

Lane Controller Light Board 1 Connects lane controller light board 1

Lane Controller Light Board 2 Connects lane controller light board 2

DS-K3B411SX Series Swing Barrier Quick Start Guide

23

Terminal Name Description

Fan 1 Connects fan 1

Fan 2 Connects fan 2

TAMPER Connects TAMPER

Lane Controller Board Connect main lane controller board

Port 5

Note External card reader is recommended to access.

Red 12 V: connects 12 VDC power supply terminal

Yellow 485E/232E+: card reader RS-485E+/RS-232E+ access terminal

Blue 485E/232E-: card reader RS-485E-/RS-232E- access terminal

Black GND: grounding

Port 6

Note External face recognition terminal is recommended to access.

Red 12 V: connects 12 VDC power supply terminal

Yellow 485F/232F+: card reader RS-485F+/RS-232F+ access terminal

Blue 485F/232F-: card reader RS-485F-/RS-232F- access terminal

Black GND: grounding

Table 4-3 BUS Terminal in Sub Lane Controller (Middle Pedestal)

Terminal Name Description

Lane Controller Light Board 1 Connects lane controller light board 1

Lane Controller Light Board 2 Connects lane controller light board 2

Lane Controller Board Connect main lane controller board

Port 5

Note External card reader is recommended to access.

Red 12 V: connects 12 VDC power supply terminal

Yellow 485E/232E+: card reader RS-485E+/RS-232E+ access terminal

Blue 485E/232E-: card reader RS-485E-/RS-232E- access terminal

Black GND: grounding

Port 6

Note External face recognition terminal is recommended to access.

Red 12 V: connects 12 VDC power supply terminal

Yellow 485F/232F+: card reader RS-485F+/RS-232F+ access terminal

Blue 485F/232F-: card reader RS-485F-/RS-232F- access terminal

Black GND: grounding

DS-K3B411SX Series Swing Barrier Quick Start Guide

24

4.5.4 Access Control Board Terminal Description

Access control board is mainly used for authority identification in places with high security levels such as public security or judicial place, external device accessing, and communication with the upper platform and lane controller.

Figure 4-13 Access Control Board Terminal

Table 4-4 Access Control Board Terminal Description

Access Control Board Terminal Description

Power Output 1 +12 V 12 VDC Power Output /

G Grounding

RS-485 Interface RS-485 C+ Connect to Card Reader RS485+ RS-485 card reader ID factory DIP is 1 and 3. 1

RS-485 C- Connect to Card Reader RS485-

GND Grounding

DS-K3B411SX Series Swing Barrier Quick Start Guide

25

Access Control Board Terminal Description

represents the passage entrance, and 3 represents the passage exit. UART 1 in the main control board corresponds to the entrance card reader, and UART 5 in the main control board corresponds to the exit card reader.

If you has configured a guest card, the exit needs to be connected to two card readers, one with the DIP 4 and the other with the DIP 3. The card reader 3 and the card receiver are used together, the ordinary user swipes the card on the card reader

DS-K3B411SX Series Swing Barrier Quick Start Guide

26

Access Control Board Terminal Description

4, and the guest user swipes the card on the card reader 3.

This is the RS-485 interface, which cannot be switched by dialing.

If you have to connect card reader, face recognition module, and fingerprint module at the same time, you should connect the card reader and the face recognition module to a same RS-485 interface, while the fingerprint module can connect to an RS-485/ RS-232 interface with the jumper cap.

Power Output 2 5 V 5 VDC Power Output /

G Grounding

DS-K3B411SX Series Swing Barrier Quick Start Guide

27

Access Control Board Terminal Description

RS-232 Interface G Grounding This is the RS-232 interface, which cannot be switched by dialing.

The RS-232 interface's QR code transmission database should no more than 64 bit.

By default, there is no QR code scanner on the left pedestal of the device entrance. If you need to connect an additional QR code scanner, you need to connect it through the RS-232 interface here. After the cable is connected to the RS-232 interface, it passes through the embedded pipe and

RS-232 G- Connect to RS-232G-

RS-232 G+ Connect to Card Reader RS-232G+

G Grounding

RS-232 H- Connect to RS-232H-

RS-232 H+ Connect to Card Reader RS-232H+

DS-K3B411SX Series Swing Barrier Quick Start Guide

28

Access Control Board Terminal Description

connects with the QR code on the left.

Power Input +24 V 24 VDC Power Input /

GND Grounding

Event Input C1 Event Alarm Input 1 The event alarm input hardware interface is remaining open, and only supports access to remaining open signals, which can be linked to the host buzzer output, card reader buzzer output, alarm relay output, door open relay output, etc.

G Grounding

C2 Event Alarm Input 2

Exit Button B2 Door 2 Signal Input /

G Grounding

B1 Door 1 Signal Input

Door Lock (Relay) D1- Door 1 Relay Output (Dry Contact) If necessary, the door lock relay can be used to control the third-party barrier switch. D1 controls the door opening for ordinary entrance, and

D1+

DS-K3B411SX Series Swing Barrier Quick Start Guide

29

Access Control Board Terminal Description

D2 controls the door opening for ordinary exit.

D2- Door 2 Relay Output (Dry Contact) If necessary, the door lock relay can be used to control the third-party barrier switch. D1 controls the door opening for ordinary entrance, and D2 controls the door opening for ordinary exit.

D2+

Alarm Output NO/NC1 Alarm Output Relay 1 (Dry Contact) The alarm output supports switch output.

COM1

NO/NC2 Alarm Output Relay 2 (Dry Contact) The alarm output supports switch output.

COM2

Loudspeaker / Connect to loudspeaker /

Network Interface LAN Network Accessing /

Fire Input XF Fire input /

G Grounding

Note You can swtich between RS-485 and RS-232 via the DIP switch on the access control board. For

details about DIP switch and swiching method, see Access Control Board UART Description . For details about DIP switch operation, see DIP Switch Description .

DS-K3B411SX Series Swing Barrier Quick Start Guide

30

4.5.5 Access Control Board UART Description

You can set the device mode, switch the communication mode of the corresponding UART, and initialize the device through the DIP on the access control board. The DIP switch of the access control board is shown in the figure below:

Note The diagram is for reference only.

Figure 4-14 DIP Switch on Access Control Board

DIP A can set the device mode, DIP 2 to 5 can set the RS-485/RS-232 interface, and DIP B can also be used to initialize the device. The UART corresponding to the DIP Switch is shown in the figure below:

DS-K3B411SX Series Swing Barrier Quick Start Guide

31

Figure 4-15 UART No. Description

The corresponding functions of different DIP Switch are described as follows:

No. Device Mode UART No. Function Binary Value

DIP A 1 to 2: Work Mode

/ Normal Mode

Test Mode

DS-K3B411SX Series Swing Barrier Quick Start Guide

32

No. Device Mode UART No. Function Binary Value

3: Memory Mode Enable Memory Mode

Disable Memory Mode

4: Keyfob Paring Mode

Enable Keyfob Paring Mode

Disable Keyfob Paring Mode

5 to 8: Passing Mode

Controlled Bi- direction

Controlled Entrance and Prohibit Exit

Controlled Entrance and Free Exit

Free Bi-direction

Free Entrance and Controlled Exit

Free Entrance and Prohibit Exit

Prohibited Bi- direction

DS-K3B411SX Series Swing Barrier Quick Start Guide

33

No. Device Mode UART No. Function Binary Value

Prohibit Entrance and Controlled Exit

Prohibit Entrance and Free Exit

DIP B 1 to 3 UART 5 ON: UART 5 is RS- 232E Interface

/

4 to 6 ON: UART 5 is RS- 485E Interface

/

7 / Reserved /

8 / Default is OFF. You can dial to ON for initial operation

/

DIP C 1 to 3 UART 6 ON: UART 6 is RS- 232F Interface

/

4 to 6 ON: UART 6 is RS- 485F Interface

/

7 / Reserved /

8 / Reserved /

DIP D 1 to 3 UART 1 ON: UART 1 is RS- 232A Interface

/

4 to 6 ON: UART 1 is RS- 485A Interface

/

7 / Reserved /

8 / Reserved /

DIP E 1 to 3 UART 3 ON: UART 3 is RS- 232C Interface

/

4 to 6 ON: UART 3 is RS- 485C Interface

/

7 / Reserved /

8 / Reserved /

DS-K3B411SX Series Swing Barrier Quick Start Guide

34

Note For proper communication between turnstile and peripherals, DIP Switch No. 1 to 3, 4 to 6, 7, and 8 of DIP B, DIP C, DIP D, and DIP E cannot be turned ON at the same time.

The reserved UART terminal positions in the turnstile and their corresponded UART No. are as follows:

Note The diagram is for reference only.

Figure 4-16 Interface and Corresponded UART No.

DS-K3B411SX Series Swing Barrier Quick Start Guide

35

4.5.6 RS-485 Wiring

Note The RS-485 interfaces are for connecting ID card reader, IC card reader, card reader, card recycler,

text screen, and face recognition terminal. Take the wiring of RS-485 card reader as an example. For details about text screen, see Configuring Screen Parameters in User Manual of iVMS-4200

AC Client Software.

DS-K3B411SX Series Swing Barrier Quick Start Guide

36

4.5.7 RS-232 Wiring

Note Access control board of pedestal can connect QR code scanner, card recycler, and face recognition terminal via RS-232 interface.

For details about text screen, see Configuring Screen Parameters in User Manual of iVMS-4200 AC Client Software.

Take the wiring of text screen as an example.

DS-K3B411SX Series Swing Barrier Quick Start Guide

37

4.5.8 Barrier Control Wiring

By default, the barrier has connected with the access control board. The lane control board can control the barrier status. If possible, the device can connect with a third party lane control board to control the third party barriers. Interface D1 controls barrier opening for entrance, while interface D2 controls barrier opening for exit.

Note Use the jumper cap to switch the relay status. For details, see Barrier Control Relay Output Mode .

Entering Wiring

Exiting Wiring

DS-K3B411SX Series Swing Barrier Quick Start Guide

38

4.5.9 Alarm Output Wiring

Note For details about changing the relay output status via the jumper cap, see Alarm Relay Output Mode (NO/NC) .

4.5.10 Exit Button Wiring

You can view the exit button wiring diagram.

Figure 4-17 Exit Button Wiring

DS-K3B411SX Series Swing Barrier Quick Start Guide

39

Chapter 5 Device Settings

After installation and wiring completed, the turnstile will learn the open and closed position automatically. After the learning, the turnstile is in the normal mode. You can also set the turnstile to test mode, passing mode and memory mode, pair the keyfob, initialize the hardware, switching between RS-485 communication mode and RS-232 communication mode, and view relay output NO/NC diagram by setting the DIP switch on the access control board. Normal Mode: The device will work properly. Test Mode: Test mode is the same as the normal mode except that the device cannot report the

alarm, the event, or the people counting information to the center. Passing Mode: There are 9 passing modes, including controlled bi-direction, controlled entrance

and prohibited exit, controlled entrance and free exit, free bi-direction, free entrance and controlled exit, free entrance and prohibited exit, prohibited bi-direction, prohibited entrance and free exit.

Memory Mode: By default, the memory mode is enabled. When multiple cards are presented and authenticated, it allows multiple persons passing through the lane. When it counts the passing people number is equal to the card presented times, or no person passing through the lane after the last person passing, the barriers will be closed.

Note You can also set the DIP switch on the access control board to control the entrance and exit controlling type, keyfob pairing, etc. For details about the DIP switch value, see Access Control Board UART Description .

5.1 Pair Keyfob (Optional) Pair the remote control to the device through DIP switch to open/close the barrier remotely.

Before You Start Ask our technique supports or sales and purchase the keyfob.

Steps

Note Up to 32 keyfobs can be added to the turnstile. You can set the keyfob to one-to-one mode or one-to-many mode via the DIP switch on the

keyfob. Here takes one-to-one mode as an example to explain. For one-to-many mode, see the keyfob user manual. One-to-One Mode

DS-K3B411SX Series Swing Barrier Quick Start Guide

40

By default, the keyfob is in one-to-one mode. The keyfob's DIP switch is towards 1 (OFF). The keyfob can control only one turnstile.

One-to-Many Mode The keyfob's DIP switch is ON. In this mode, the keyfob can control multiple turnstiles.

1. Power off the turnstile. 2. Set the No.4 switch of the DIP 1 Switch on the access control board to the ON side.

3. Power on the turnstile and it will enter the keyfob pairing mode. 4. Hold the Close button for more than 10 seconds. Or pair turnstile and keyfob in the client

software, see Manage Keyfob User for more details. The keyfob's indicator of the will flash twice if the pairing is completed.

5. Set the No.4 switch to OFF, and reboot the turnstile to take effect.

Note Only one turnstile can pair the keyfob. If multiple turnstiles are in the pairing mode, the

keyfob will select only one of them to pair. For details about DIP switch value and meaning, see Access Control Board UART Description .

6. Optional: Go to System User Keyfob User on the remote control page of the client software to delete the keyfob.

5.2 Initialize Device Steps 1. Set the No.8 switch of the DIP 2 Switch on the access control board to the ON side.

DS-K3B411SX Series Swing Barrier Quick Start Guide

41

Figure 5-1 Initialization Jumper Cap 2. Disconnect the power and reboot the device. The device buzzer buzzes a long beep. 3. When the beep stopped, set the No.8 switch to the OFF side, and reboot the turnstile to take

effect. 4. Disconnect the power and power on the device again.

Caution The initialization of the device will restore all the parameters to the default setting and all the device events are deleted.

Note Make sure no persons are in the lane when powering on the device.

5.3 Switch Relay Output Mode (NO/NC)

5.3.1 Barrier Control Relay Output Mode

The jumper cap of the barrier control relay on the access control board is as below:

DS-K3B411SX Series Swing Barrier Quick Start Guide

42

Figure 5-2 Jumper Cap Location (Barrier Control Relay Output Mode)

The jumper cap position of barrier opening (NO) is as below:

Figure 5-3 Barrier Opening (NO)

The jumper cap position of barrier closing (NC) is as below:

DS-K3B411SX Series Swing Barrier Quick Start Guide

43

Figure 5-4 Barrier Closing (NC)

Note The default status is NC.

5.3.2 Alarm Relay Output Mode (NO/NC)

The jumper cap of the alarm relay on the access control board is as below:

DS-K3B411SX Series Swing Barrier Quick Start Guide

44

Figure 5-5 Jumper Cap Location (Alarm Relay Output Mode)

The jumper cap position of alarm opening (NO) is as below:

Figure 5-6 Alarm Opening (NO)

The jumper cap position of alarm closing (NC) is as below:

DS-K3B411SX Series Swing Barrier Quick Start Guide

45

Figure 5-7 Alarm Closing (NC)

Note The default status is NO.

DS-K3B411SX Series Swing Barrier Quick Start Guide

46

Chapter 6 Activation

You should activate the device before the first login. After powering on the device, the system will switch to Device Activation page.

Activation via the device, SADP tool and the client software are supported. The default values of the device are as follows: The default IP address: 192.0.0.64 The default port No.: 8000 The default user name: admin

6.1 Activate via SADP SADP is a tool to detect, activate and modify the IP address of the device over the LAN.

Before You Start Get the SADP software from the supplied disk or the official website http:// www.hikvision.com/en/ , and install the SADP according to the prompts.

The device and the PC that runs the SADP tool should be within the same subnet. The following steps show how to activate a device and modify its IP address. For batch activation and IP addresses modification, refer to User Manual of SADP for details.

Steps 1. Run the SADP software and search the online devices. 2. Find and select your device in online device list. 3. Input new password (admin password) and confirm the password.

Caution STRONG PASSWORD RECOMMENDED-We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product.

4. Click Activate to start activation.

DS-K3B411SX Series Swing Barrier Quick Start Guide

47

Status of the device becomes Active after successful activation. 5. Modify IP address of the device.

1) Select the device. 2) Change the device IP address to the same subnet as your computer by either modifying the IP

address manually or checking Enable DHCP. 3) Input the admin password and click Modify to activate your IP address modification.

6.2 Activate Device via Client Software For some devices, you are required to create the password to activate them before they can be added to the software and work properly.

Steps

Note This function should be supported by the device.

1. Enter the Device Management page. 2. Click on the right of Device Management and select Device. 3. Click Online Device to show the online device area.

The searched online devices are displayed in the list. 4. Check the device status (shown on Security Level column) and select an inactive device. 5. Click Activate to open the Activation dialog. 6. Create a password in the password field, and confirm the password.

DS-K3B411SX Series Swing Barrier Quick Start Guide

48

Caution The password strength of the device can be automatically checked. We highly recommend you change the password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you change your password regularly, especially in the high security system, changing the password monthly or weekly can better protect your product. Proper configuration of all passwords and other security settings is the responsibility of the installer and/or end-user.

7. Click OK to activate the device.

DS-K3B411SX Series Swing Barrier Quick Start Guide

49

Appendix A. DIP Switch Description

The DIP switch is on the main lane control board. The left side to the right side is from the low bit to the high bit.

When the switch is towards ON, it means the switch is enabled, otherwise, the switch is off. If you set the DIP switch like the figure displayed below, its binary value is 00001100, and its decimal value is 12.

DS-K3B411SX Series Swing Barrier Quick Start Guide

50

Appendix B. Event and Alarm Type

Event Alarm Type

Tailgating Visual and Audible

Reverse Passing Visual and Audible

Force Accessing None

Climb over Barrier Visual and Audible

Overstay Visual and Audible

Passing Timeout None

Intrusion Visual and Audible

Free Passing Authentication Failed

Visual

Barrier Obstructed None

DS-K3B411SX Series Swing Barrier Quick Start Guide

51

Appendix C. Table of Audio Index Related Content

Index Content

1 Authenticated.

2 Card No. does not exist.

3 Card No. and fingerprint mismatch.

4 Climbing over the barrier.

5 Reverse passing.

6 Passing timeout.

7 Intrusion.

8 Force accessing.

9 Tailgating.

10 No permissions.

11 Authentication time out.

12 Authentication failed.

13 Expired card.

14 Stay out of time.

DS-K3B411SX Series Swing Barrier Quick Start Guide

52

Appendix D. Error Code Description

The swing barrier will display the error code on the seven-segment display if error occurred. Refer to the table below to find the description of each number.

Error Reason Code Error Reason Code

Normal Working 00 Upper IR Board 5 Offline 29

The First IR Beam on Upper IR Board Triggered

01 Upper IR Board 6 Offline 30

The Second IR Beam on Upper IR Board Triggered

02 Upper IR Board 7 Offline 31

The Third IR Beam on Upper IR Board Triggered

03 Upper IR Board 8 Offline 32

The Fourth IR Beam on Upper IR Board Triggered

04 Upper IR Board 9 Offline 33

The Fifth IR Beam on Upper IR Board Triggered

05 Upper IR Board 10 Offline 34

The Sixth IR Beam on Upper IR Board Triggered

06 Upper IR Board 11 Offline 35

The Seventh IR Beam on Upper IR Board Triggered

07 Upper IR Board 12 Offline 36

The Eighth IR Beam on Upper IR Board Triggered

08 Lower IR Board 1 Offline 37

The Ninth IR Beam on Upper IR Board Triggered

09 Lower IR Board 2 Offline 38

The Tenth IR Beam on Upper IR Board Triggered

10 Lower IR Board 3 Offline 39

The Eleventh IR Beam on Upper IR Board Triggered

11 Lower IR Board 4 Offline 40

The Twelfth IR Beam on Upper IR Board Triggered

12 Lower IR Board 5 Offline 41

The First IR Beam on Lower IR Board Triggered

13 Lower IR Board 6 Offline 42

DS-K3B411SX Series Swing Barrier Quick Start Guide

53

Error Reason Code Error Reason Code

The Second IR Beam on Lower IR Board Triggered

14 Lower IR Board 7 Offline 43

The Third IR Beam on Lower IR Board Triggered

15 Lower IR Board 8 Offline 44

The Fourth IR Beam on Lower IR Board Triggered

16 Lower IR Board 9 Offline 45

The Fifth IR Beam on Lower IR Board Triggered

17 Lower IR Board 10 Offline 46

The Sixth IR Beam on Lower IR Board Triggered

18 Lower IR Board 11 Offline 47

The Seventh IR Beam on Lower IR Board Triggered

19 Lower IR Board 12 Offline 48

The Eighth IR Beam on Lower IR Board Triggered

20 Light Board Offline (Entrance) 49

The Ninth IR Beam on Lower IR Board Triggered

21 Light Board Offline (Exit) 50

The Tenth IR Beam on Lower IR Board Triggered

22 IR Adapter Offline (Up) 51

The Eleventh IR Beam on Lower IR Board Triggered

23 IR Adapter Offline (Low) 52

The Twelfth IR Beam on Lower IR Board Triggered

24 CAN Bus Exception 53

Upper IR Board 1 Offline 25 Not Studying 54

Upper IR Board 2 Offline 26 Obstruction 55

Upper IR Board 3 Offline 27 Exceeding Studying Range 56

Upper IR Board 4 Offline 28 Motor Exception 57

DS-K3B411SX Series Swing Barrier Quick Start Guide

54

Appendix E. Communication Matrix and Device Command

Communication Matrix Scan the following QR code to get the device communication matrix. Note that the matrix contains all communication ports of Hikvision access control and video intercom devices.

Figure E-1 QR Code of Communicati

Manualsnet FAQs

If you want to find out how the DS-K3B411SX-LS Hikvision works, you can view and download the Hikvision DS-K3B411SX-LS Barrier Quick Start Guide on the Manualsnet website.

Yes, we have the Quick Start Guide for Hikvision DS-K3B411SX-LS as well as other Hikvision manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Quick Start Guide should include all the details that are needed to use a Hikvision DS-K3B411SX-LS. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Hikvision DS-K3B411SX-LS Barrier Quick Start Guide is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Hikvision DS-K3B411SX-LS Barrier Quick Start Guide consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Hikvision DS-K3B411SX-LS Barrier Quick Start Guide free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Hikvision DS-K3B411SX-LS Barrier Quick Start Guide, simply download the document to your computer. Once downloaded, open the PDF file and print the Hikvision DS-K3B411SX-LS Barrier Quick Start Guide as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.