Hikvision DS-K3B220X-R Barrier Quick Start Guide PDF

1 of 2
1 of 2

Summary of Content for Hikvision DS-K3B220X-R Barrier Quick Start Guide PDF

DS-K3B220X Series Swing Barrier

Quick Start Guide

UD30049B-A

2022 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved. About this Manual The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website (https://www.hikvision.com/). Please use this Manual with the guidance and assistance of professionals trained in supporting the Product. Trademarks

and other Hikvisions trademarks and logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned are the properties of their respective owners. Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED AS IS AND WITH ALL FAULTS AND ERRORS. HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER PREVAILS. Data Protection During the use of device, personal data will be collected, stored and processed. To protect data, the development of Hikvision devices incorporates privacy by design principles. For example, for device with facial recognition features, biometrics data is stored in your device with encryption method; for fingerprint device, only fingerprint template will be saved, which is impossible to reconstruct a fingerprint image. As data controller, you are advised to collect, store, process and transfer data in accordance with the applicable data protection laws and regulations, including without limitation, conducting security controls to safeguard personal data, such as, implementing reasonable administrative and physical security controls, conduct periodic reviews and assessments of the effectiveness of your security controls.

1 System Wiring 2 Installation

3 Wiring

1. Draw a central line on the installation surface of the left or right pedestal. 2. Draw other parallel lines for installing the other pedestals.

The distance between the nearest two lines is L + 146 mm. L represents the lane width.

3. Slot on the installation surface and dig installation holes according to the hole position. Put 4 expansion bolts of M12*120 for each pedestal. 4. Bury cables. Each lane buries 1 high voltage cable and 1 low voltage cable. For details, see the system wiring diagram.

High voltage: AC power input Low voltage: interconnecting cable (communication cable and 24 V power cable) and network communication cable. The supplied interconnecting power cable length is 2.5 m and communication cable length is 3 m. The suggested inner diameter of the low voltage conduit is larger than 30 mm. If you want to bury both of the AC power cord and the low voltage cable, the two cables should be in separated conduits to avoid interference. If more peripherals are required to connect, you should increase the conduit diameter or bury another conduit for the external cables. The external AC power cord should be double-insulated. The network cable must be CAT5e or the network cable has better performance.

Steps:

Main Switch Main Switch

12 00 m m

75 mm

10 47 m m

L + 146 mm

L

Fix each pedestal with 4 expansion bolts of M12*120

Entrance

High Voltage

Low Voltage Low Voltage

Main/Sub Lane Control Board

Access Control Board

Main Optional Board

Sub Optional Board

Sub Lane Control Board Main Lane Control Board

Access Control Board

Main Optional Board

Sub Optional Board

1 1

11 3

3

4

42 2

2 2

Steps: 1. Place the pedestal above the embedded expansion bolt. 2. Unscrew the lower maintenance door and remove the maintenance door. 3. Place the platen on the expansion bolt and adjust the position of the pedestal to make sure the platen fits well to the bottom of the pedestal. 4. Fasten the nuts of the expansion bolts with a screwdriver (shaft diameter under 7 mm and shank length more than 120 mm) and reinstall the maintenance door.

20mm

Expansion Bolt

PlatenM12 Screw

Each pedestal should be fixed with two floor platens.

If the installation area is close to the wall, make sure the distance between the pedestal and the wall should be more than 20 mm, or you cannot open the pedestal's top panel.

146 mm

1200 mm

10 00

m m

29 0

m m

72 0

m m

Dimension

Scan the QR code to view the user manual.

ALARM IN

BUS1

USB

12VOUT

MAIN CROSS

GND

BTN2 GND BTN1

24VIN

GND

GND

TA M

P LE

D1 LE

D2

BU S2

EN CO

DE R

M OT

O R

CA P

IR R2

IR R1

FA N

Tamper Interface

Main Lane Control Board

Light Bar Interface 1

Light Bar Interface 2

Fan

Communication Interface (For Main Optional Board)

Encoder Interface

Power Supply for Motor

Supercapacitor

IR Adaptor 2

IR Adaptor 1

Interconnecting Interface

(For Sub Lane Control Board)

Reserved

Access Control Board Interface

Fire Input

Exit Button

12 VDC Output

(Reserved)

24 VDC Input

Light Bar Interface 2 Light Bar Interface 1 Tamper Interface

Fan

Communication Interface

For Sub Optional Board

Encoder Interface

Power Supply for Motor

Supercapacitor

IR Adaptor 1

IR Adaptor 2

Reserved

12 VDC Output (Reserved)

BUS Interface (For Sub Optional Board )

Exit Button

24 VDC Input

Interconnecting Interface (For Main Lane Control Board)

Sub Lane Control Board

BUS1

USB

MAIN CROSS

BTN2 GND BTN1

12VOUT

24VIN

GND

GND

TAM P

LED1 LED2

BUS2 ENCO

DER M

OTO R

CAP IRR2

IRR1 FAN

Access Control Board

Reserved

Reserved

Reserved

Reserved

Network Interface

SOC Serial Port

MCU Serial Port USB Interface

DIP Switch

Reserved Main Lane Control Board Interface

Extended Interface

12 VDC Output

RS-485 Interface

24 VDC Input

SOC

WIFI LAN

SWITCH

BUS1 TO MAIN LANE CONTROL BOARD

USB

GND

12VOUT

RS485C-

RS485A-

RS485C+

RS485A+

24VIN

GND

MIC

SPK MCU

BUS4

BUS3

MAIN CROSS

DEBUG1 DEBUG2

Reset Button

SOC and MCU serial port are for debugging and maintenance use only.

Hold the reset button for 5 s, the device will beep for 3 s and start restoring to factory settings.

The DIP switch is for study mode settings and keyfob pairing. Refer to the user manual for details.

RS-485A corresponds to port 5 on web and is for QR code scanner connection by default; RS-485C corresponds to port 7 on web and is for card reader connection by default.

Entrance

Main/Sub Lane Control Board

Sub Lane Control Board

Access Control Board

Access Control BoardMain Optional Board (Optional)

Power Supply Power Supply

Circuit Breaker Circuit Breaker Sub Optional Board

Sub Optional Board

Card Reader QR Code Scanner (Optional) Antenna (Optional)

Main Optional Board (Optional)

Main Lane Control Board

Scan the QR code to view the unboxing video.

Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. FCC Conditions This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation.

This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the RE Directive 2014/53/EU, the EMC Directive 2014/30/EU, the RoHS Directive 2011/65/EU.

2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see: www.recyclethis.info

2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info

Screen Display

Add 10 (LEFT)

Exit Button Add 1

(RIGHT) CANCEL OK

Configuration data: Configuration data is displayed by two digital tubes LEFT: Press this button to add ten to configuration data RIGHT: Press this button to add one configuration data CANCEL: Return to the level-1 menu, or exit the configuration from the level-1 menu. OK: Confirm the data, or enter configuration mode, or enter the submenu. Level-1 Menu: If the decimal point on the right is on, it indicates the level-1 menu. The number represents the configuration item number. Level-2 Menu: if the decimal point in the middle is on, it indicates the level -2 menu. The number represents the parameters of a configuration item.

Parameter Configration Button

Single press to open from the entrance position. Double press to open from the exit position.

Exit Button

Warning In the use of the product, you must be in strict compliance with the electrical safety regulations of the nation and region. Do not connect several devices to one power adapter as adapter overload may cause over-heat or fire hazard. If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then please contact the service center. The socket-outlet shall be installed near the equipment and shall be easily accessible. 1. Do not ingest battery. Chemical burn hazard! 2. This product contains a coin/button cell battery. If the coin/button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death. 3. Keep new and used batteries away from children. 4. If the battery compartment does not close securely, stop using the product and keep it away from children. 5. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention. 6. CAUTION: Risk of explosion if the battery is replaced by an incorrect type. 7. Improper replacement of the battery with an incorrect type may defeat a safeguard (for example, in the case of some lithium battery types). 8. Do not dispose of the battery into fire or a hot oven, or mechanically crush or cut the battery, which may result in an explosion. 9. Do not leave the battery in an extremely high temperature surrounding environment, which may result in an explosion or the leakage of flammable liquid or gas. 10. Do not subject the battery to extremely low air pressure, which may result in an explosion or the leakage of flammable liquid or gas. 11. Dispose of used batteries according to the instructions Caution Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage). Do not place the device in extremely hot (refer to the specification of the device for the detailed operating temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation. Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is forbidden (ignorance can cause fire danger). The device cover for indoor use shall be kept from rain and moisture. Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is forbidden (ignorance can cause fire danger). Please use a soft and dry cloth when clean inside and outside surfaces of the device cover, do not use alkaline detergents. Biometric recognition products are not 100% applicable to anti-spoofing environments. If you require a higher security level, use multiple authentication modes. The serial port of the equipment is used for debugging only. Wall Mounting: Install the equipment according to the instructions in this manual. To prevent injury, this equipment must be securely attached to the floor/wall in accordance with the installation instructions. Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or equivalent type only. Dispose of used batteries according to the instructions provided by the battery manufacturer. This bracket is intended for use only with equipped devices. Use with other equipment may result in instability causing injury. This equipment is for use only with equipped bracket. Use with other (carts, stands, or carriers) may result in instability causing injury.

Safety Instructions

Level-1 Menu

Level-2 Menu

Startup

Display error code

Press RIGHT to add 1

Press LEFT to add 10

Hold OK for 3 s to enter leval 1 menu

Press OK to enter level-2 menu

Press RIGHT to add 1

Press LEFT to add 10

Press OK to save the paramter and back to level-1 menu

Conduct no operation for 5 s and the screen displays error code

End

5 Button Description

5 Button Description

Enter the configuration mode. The number of 1 will show up on the right side of the screen and the device is ready for configuration.

Press LEFT and RIGHT to set the configuration No. Press OK to enter the level-2 menu and view the parameters. Press CANCEL, or conduct no operation for 5 s to cancel configuration.

Press LEFT and RIGHT to set the parameters at your needs. Press OK to save the change or press CANCEL back to configuration No. setting without saving changes. Conduct no operations for 5 s to cancel configuration.

32 23 41 14

Access Control Board

Main Optional BoardSub Optional Board Sub Optional Board

24 V Power Cable

24 V Power Cable

Communication Cable

Communication Cable

Power Input 200 ~ 240 VAC

2 Access Control Board 22 2

4Wiring Diagram

The power cable from power supply to the main lane control board has been connected. You will need to prepare the 14AWG power cable to connect the AC power input to power supply.

The supplied 2 interconnecting cables need connecting on-site: 1. 24 V power cable of 14 AWG. The cable is 2.5 m in length and put inside the right/middle pedestal at the exit. 2. UTP-5e Communication cable. The cable is 3 m in length and put inside the package of the right/middle pedestal.

The and or and refer to the two sides of a same board.

Barrier opens at the entrance/exit: connect to BTN1/BTN2 and GND.

If the optional board is not installed, the error code of "49" will appear but the device functions normally.

Refer to the user manual for botton description details.

Power Supply Power Supply

Filter Board Filter Board

Sub Lane Control Board

Sub Lane Control Board

Main Lane Control Board

Main Lane Control Board

Main Lane Control Board

Main Lane Control Board

Sub Lane Control Board

Sub Lane Control Board

Left Middle Right

Main Optional Board (Optional)

Main Optional Board

Sub Optional Board

Sub-1G

RS485B+

RS485D+ RS485B-

RS485D- RS232BT

RS232CT RS232BR

RS232CR

12VOUT

LED1

LED2

SPK

GND

485/232 Terminals

12 VDC Output

Lane Control Board Interface

Wiegand/Exit Button Interface

5 VDC Output

RS-485 Interface

1

1

2

2

Sub-1G Antenna

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved Loudspeaker

Interface

Wiegand/Exit Button Interface

Serial Port

5 V Power Output

Communication Interface (For Main Lane Control Board)

Reserved

BZ

BZ BZ

W1

W1 W1

W0

W0 W0

GND

GND GND

BTN

BTN BTN

GND

GND GND

GND

GND GND

5VOUT

5VOUT 5VOUT

BUS2

BUS2 BUS2

BUS1 TO SUB

BUS1 TO SUB

BUS1 TO SUB

SUB CROSS

SUB CROSS

SUB CROSS

RS-485B corresponds to port 6 on web and is for QR code scanner connection by default; RS-232B corresponds to port 2 on web and is for fingerprint reader connection by default.

Access Control Board Interface

Card Reader Board

125 K Antenna

Debugging Port

DIP Switch

Reserved

13.56 M Antenna

485- 485+ GND 12 VDC

BUS1

USB

MAIN CROSS

BTN2 GND BTN1

12VOUT

24VIN

GND

GND

BUS1

USB

MAIN CROSS

BTN2 GND BTN1

12VOUT

24VIN

GND

GND

TAM P

LED1 LED2

BUS2 ENCO

DER M

OTO R

CAP IRR2

IRR1 FAN

TAM P

LED1 LED2

BUS2 ENCO

DER M

OTO R

CAP IRR2

IRR1 FAN

LAN

SWITCH

USB

GND

12VOUT

RS485C-

RS485A-

RS485C+

RS485A+

24VIN

GND

LAN

SWITCH

USB

GND

12VOUT

RS485C-

RS485A-

RS485C+

RS485A+

24VIN

GND

ALARM IN

BUS1

USB

12VOUT

MAIN CROSS

GND

BTN2 GND BTN1

24VIN

GND

GND

ALARM IN

BUS1

USB

12VOUT

MAIN CROSS

GND

BTN2 GND BTN1

24VIN

GND

GND

Manualsnet FAQs

If you want to find out how the DS-K3B220X-R Hikvision works, you can view and download the Hikvision DS-K3B220X-R Barrier Quick Start Guide on the Manualsnet website.

Yes, we have the Quick Start Guide for Hikvision DS-K3B220X-R as well as other Hikvision manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Quick Start Guide should include all the details that are needed to use a Hikvision DS-K3B220X-R. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Hikvision DS-K3B220X-R Barrier Quick Start Guide is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Hikvision DS-K3B220X-R Barrier Quick Start Guide consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Hikvision DS-K3B220X-R Barrier Quick Start Guide free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Hikvision DS-K3B220X-R Barrier Quick Start Guide, simply download the document to your computer. Once downloaded, open the PDF file and print the Hikvision DS-K3B220X-R Barrier Quick Start Guide as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.