SS-GMVC80/GCVC80 www.goodmanmfg.com 12/21 Supersedes 12/21
Two-Stage, Variable-Speed ECM Gas Furnace
80% AFUE
GMVC80(A) / GCVC80(A) Heating Input: 60,000100,000 BTU/h
Contents Nomenclature ........................................ 2 Product Specifications ........................... 3 Dimensions ............................................ 5 Airflow Data ........................................... 7 Accessories ............................................ 8 Wiring Diagram ................................... 10
Standard Features Integrated communicating ComfortBridge technology Two-stage gas valve provides quiet,
economical heating Commissioning and diagnostics via on board
Bluetooth with the CoolCloud phone and tablet application
Efficient and quiet variable-speed ECM circulator motor gently ramps up or down according to heating or cooling demand
SureStart Silicon Nitride igniter designed for long igniter life
Self-diagnostic control board with constant memory fault code history output to a triple 7-segment display
Low constant fan speed circulates air throughout the home
Quiet, two-speed induced draft blower California Low NOx emissions-compliant
models available Can no longer be installed in Californias
South Coast Air Quality Management District (SCAQMD) on or after October 1, 2019.
AHRI Certified; ETL Listed
Cabinet Features Fully insulated, heavy-gauge steel cabinet
with durable baked-enamel finish Multi-position installation:
GMVC80: upflow, horizontal left or right GCVC80: downflow, horizontal left or right
Removable bottom for side- or bottom-return applications
Convenient left or right connection for gas/electric service
Cabinet air leakage 2% Coil and furnace fit flush
for most installations
* Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Qubec.
2 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 3
Nomenclature
G M V C 80 040 4 C * **
1 2 3 4 5,6 7,8,9 10 11 12 13,14
Brand Engineering
G - Goodman Brand Major /Minor Revisions * Not used for inventory control.
Configuration NOx
M - Upflow/Horizontal N - Natural Gas
C - Downflow/Horizontal X - Low NOx
Motor Cabinet Width
V - Variable Speed ECM / ComfortBridge A - 14" C - 21"
E - Multi-Speed ECM S - Single Speed B - 17" D - 24"
Gas Valve Maximum CFM
M - Modulating S - Single Stage 2 - 800 CFM 4 - 1600 CFM
C - Two Stage 3 - 1200 CFM 5 - 2000 CFM
AFUE MBTU/h
80 - 80% AFUE 040 - 40,000 BTU/h 100 - 100,000 BTU/h
060 - 60,000 BTU/h 120 - 120,000 BTU/h
080 - 80,000 BTU/h
2 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 3
Specifications
GMVC80 0603B*A
GMVC80 0604B*A
GMVC80 0803B*A
GMVC80 0804C*A
GMVC80 0805C*A
GMVC80 0805D*A
GMVC80 1005C*A
Heating Capacity
High Fire Input (BTU/h) 60,000 60,000 80,000 80,000 80,000 80,000 100,000
High Fire Output (BTU/h) :
Natural Gas 48,000 48,000 64,000 64,000 64,000 64,000 80,000
LP Gas 48,000 48,000 64,000 64,000 64,000 64,000 80,000
Low Fire Input (BTU/h) 42,000 42,000 56,000 56,000 56,000 56,000 70,000
Low Fire Output (BTU/h) :
Natural Gas 33,600 33,600 44,800 44,800 44,800 44,800 56,000
LP Gas 33,600 33,600 44,800 44,800 44,800 44,800 56,000
AFUE 80 80 80 80 80 80 80
Available AC @ 0.5 ESP 1.5 - 3.0 1.5 - 4.0 1.5 - 3.0 3.0 - 4.0 2.0 - 5.0 2.5 - 5.0 2.0 - 5.0
Temperature Rise Range ( F) 15-45 / 15-45 20-50 / 20-50 30-60 / 35-65 25-55 / 20-50 20-50 / 20-50 20-50 / 30-60 25-55 / 25-55
Circulator Blower
Size (D x W) 10 x 8 10 x 8 10 x 8 11" x 10" 10 x 10 11" x 10" 10 x 10
Horsepower - RPM 1/2 3/4 1/2 1/2 3/4 3/4 3/4
Speed Variable ECM Variable ECM Variable ECM Variable ECM Variable ECM Variable ECM Variable ECM
Vent Diameter 4 4 4 4 4 4 4
No. of Burners 3 3 4 4 4 4 5
Electrical Data
Min. Circuit Ampacity 7.75 10.6 7.75 7.75 10.6 10.6 10.6
Max. Overcurrent Device (amps)4 15 15 15 15 15 15 15
Ship Weight (lbs) 105 107 110 118 121 129 124
Natural Gas BTU/h; for altitudes above from 0 to 4,500 above sea level, reduce input rating 4% for each 1,000 above 4,500 altitude. Low-fire rate is 70% of high-fire rate. DOE AFUE based upon Isolated Combustion System (ICS) Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs
will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.
Notes All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all
existing local codes.
4 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 5
Specifications
GCVC80 0603B*A
GCVC80 0803B*A
GCVC80 0805C*A
GCVC80 1005C*A
Heating Capacity
High Fire Input (BTU/h) 60,000 80,000 80,000 100,000
High Fire Output (BTU/h)
Natural Gas 48,000 64,000 64,000 80,000
LP Gas 48,000 64,000 64,000 80,000
Low Fire Input (BTU/h) 42,000 56,000 56,000 70,000
Low Fire Output (BTU/h)
Natural Gas 33,600 44,800 44,800 56,000
LP Gas 33,600 44,800 44,800 56,000
AFUE 80 80 80 80
Available AC @ 0.5 ESP 1.5 - 3.0 1.5 - 3.0 2.0 - 5.0 2.0 - 5.0
Temperature Rise Range ( F) 25-55 / 40-70 30-60 / 30-60 25-55 / 30-60 20-50 / 25-55
Circulator Blower
Size (D x W) 10 x 8 10 x 8 10 x 10 10 x 10
Horsepower - RPM 1/2 1/2 3/4 3/4
Speed Variable ECM Variable ECM Variable ECM Variable ECM
Vent Diameter 4 4 4 4
No. of Burners 3 4 4 5
Electrical Data
Min. Circuit Ampacity 7.75 7.75 10.6 10.6
Max. Overcurrent Device (amps) 15 15 15 15
Ship Weight (lbs) 105 109 125 129 Natural Gas BTU/h; for altitudes above from 0 to 4,500 above sea level, reduce input rating 4% for each 1,000 above 4,500 altitude. Low-fire rate is 70% of high-
fire rate. DOE AFUE based upon Isolated Combustion System (ICS) Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes.
Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit
breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.
Notes All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.
4 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 5
Minimum Clearances to Combustible Materials
Sides Rear Front Bottom Vent
Top SW B
1 0 3 C 6 1 1
C = If placed on combustible floor, the floor MUST be wood ONLY.
Notes: For servicing or cleaning, a 24 front clearance is recommended. Unit connections (electrical, flue, and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. Refer to the appropriate USA and Canadian codes:
In the USA: the National Fuel Gas Code NFPA 54 / ANSI Z223.1 In Canada: the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2
GMVC80 Dimensions
Model Dimensions Heights
W D H A B
GMVC800603B** 17 28 33" 17 16
GMVC800604B** 17 28 33" 17 16
GMVC800803B** 17 28 33" 17 16
GMVC800804C** 21 28 33" 21 19
GMVC800805C** 21 28 33" 21 19
GMVC800805D** 24 28" 33" 24 23"
GMVC801005C** 21 28 33" 21 19
28
A B
1
33
23516
1716
13
20
27 Alt. Gas Inlet
Alt. High Voltage
Alt. Low Voltage
Alternate Gas Inlet
High-Voltage Inlet
Low-Voltage Inlet
Alt. Flue Outlet Horizontal Left
19
23
15
6 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 7
GCVC80 Dimensions
A
B
High-Voltage Electrical
Low-Voltage Electrical
Gas Inlet
11
18
19
33
28
Minimum Clearances to Combustible Materials
Sides Rear Front Vent
Top SW B
1 0 3 6 1 1
Approved for line contact in the horizontal position. 24 clearance for serviceability recommended. Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables outlined in the
Installation Manual for additional venting requirements.
Model Dimensions Heights
W D H A B
GCVC800603B** 17 28 33" 17 16
GCVC800803B** 17 28 33" 17 16
GCVC800805C** 21 28 33" 21 19
GCVC801005C** 21 28 33" 21 19
6 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 7
Airflow Data
MODEL/TEMP RISE RANGE (MID RISE)
GMVC800803B*A* 30-60 (45)
GMVC800804C*A* 25-55 (40)
GMVC800805C*A* 20-50 (35)
GMVC800805D*A* 20-50 (35)
GMVC801005C*A* 25-55 (40)
CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE
Recommended cfm for high heat / expected temperature rise 1330 45 1400 42 1700 35 1700 35 1850 40
Lowest recommended cfm for hi heat / expected temperature rise 980 60 1090 54 1175 50 1175 50 1350 55
Maximum cfm for hi heat / expected temperature rise 1400 42 1760 34 2200 27 2200 27 2200 34
NOTE: Low Heat CFM = High Heat CFM X .7. Low Heat Temperature Rise Is Expected to Equal High Heat Temparatue Rise 5% 0140F02402-A
MODEL/TEMP RISE RANGE (MID RISE)
GCVC800603BXA* 25-55 (40)
GCVC800603BXA* 30-60 (45)
GCVC800805CXA* 25-55 (40)
GCVC801005CXA* 20-50 (35)
GMVC800603B*A* 15-45 (30)
GMVC800604B*A* 20-50 (35)
CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE
Recommended cfm for high heat / expected temperature rise 1100 40 1325 45 1470 40 2090 35 1400 32 1275 35
Lowest recommended cfm for hi heat / expected temperature rise 810 55 990 60 1070 55 1475 50 980 45 890 50
Maximum cfm for hi heat / expected temperature rise 1400 32 1400 42 2200 27 2200 34 1400 32 1760 25
NOTE: Low Heat CFM = High Heat CFM X .7. Low Heat Temperature Rise Is Expected to Equal High Heat Temparatue Rise 5% 0140F02402-A
GCVC800603BXA*, GCVC800803BXA* GMCV800603B*A*, GMVC800803B*A*
Cooling Speed ( @ .1 - .8 w.c. ESP)
GMVC800604B*A* GMVC800804C*A*
Cooling Speed ( @ .1 - .8 w.c. ESP)
Tons High-Stage Low-Stage CFM Tons High-Stage Low-Stage
CFM 1.5 600 420 2 800 560 2 800 560 2.5 1,000 700
2.5 1,000 700 3 1,200 840 3 1,200 840 4 1,600 1120
MAX 1,400 MAX 1,760
GCVC800805CXA* GCVC801005CXA*
Cooling Speed ( @ .1 - .8 w.c. ESP)
GMVC800805C*A*, GMVC800805D*A* GMVC801005C*A*
Cooling Speed ( @ .1 - .8 w.c. ESP)
Tons High-Stage Low-Stage CFM Tons High-Stage Low-Stage
CFM 2 800 560 2 800 560 3 1,200 840 3 1,200 840 4 1,600 1,120 4 1,600 1,120 5 2,000 1,400 5 2,000 1,400
MAX 2,000 MAX 2,200
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable. Do not operate above .5 w.c. ESP in heating mode. Operating CFM between .5 and .8 w.c. is tabulated for cooling purposes only.
8 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 9
Airflow Data (cont.)
GCVC8 Minimum Filter Sizes
Model # GCVC800603BX, GCVC80803BX GCVC800805CX GCVC801005CX
Filter Size (in) (2) 10 x 20 or (1) 16 x 25 (Top Return) (2) 14 x 20 or (1) 20 x 25 (Top Return)
Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located. Use 2 - 16 X 25 filters on side returns or 20 X 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity.
GMVC8 Minimum Filter Sizes
Model # GMVC800604B*, GMVC800603B*, GMVC800803B*
GMVC800805C*, GMVC800804C*, GMVC800805D* GMVC801005C*
Filter Size (in) (1) 16 x 25 (Side or Bottom) (1) 16 x 25 (Side or Bottom) (2) 16 x 25 (Side) or (1) 20 x 25 (Bottom)
Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located. Use 2 - 16 X 25 filters on side returns or 20 X 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity.
GMVC Continuous Fan Speeds
Model Furnace Maximum CFM
Continuous Fan Speed
GMVC800603B*A 1400 350 - 1400
GMVC800604B*A 1760 440 - 1760
GMVC800803B*A 1400 350 - 1400
GMVC800804C*A 1760 440 - 1760
GMVC800805C*A 2200 550 - 2200
GMVC800805D*A 2200 550 - 2200
GMVC801005C*A 2200 550 - 2200
GCVC Continuous Fan Speeds
Model Furnace Maximum CFM
Continuous Fan Speed
GCVC800603BXA* 1,400 350-1,400
GCVC800803BXA* 1,400 350-1,400
GCVC800805CXA* 2,200 550-2,200
GCVC801005CXA* 2,200 550-2,200
Model Description GMVC80 0603B*
GMVC80 0604B*
GMVC80 0803B*
GMVC80 0804C*
GMVC80 0805C*
GMVC80 0805D*
GMVC80 1005C*
AFE18-60A Fossil Fuel (Dual Fuel) Kit HA-02 High-Altitude Natural Gas Kit LPLP03 Low LP Gas Pressure Switch LPM-06 LP Conversion Kits
Model Description GCVC80 0603B*
GCVC80 0803B*
GCVC80 0805C*
GCVC80 1005C*
SBT17 Downflow Sub-Base 17.5" SBT21 Downflow Sub-Base 21" AFE18-60A Fossil Fuel (Dual Fuel) Kit HA-02 High-Altitude Natural Gas Kit LPLP03 Low LP Gas Pressure Switch LPM-06 LP Conversion Kits
Accessories
8 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 9
Temperature Rise Range Chart
30 40
50 60
70 80
90 11
0 12
0 10
0 13
0 14
0 15
0
10 0
90 80 70 60 50 40 30 20 10
O U
TP U
T B
TU /H
R x
10 00
B TU
O U
TP U
T vs
TE M
P E
R AT
U R
E R
IS E
C H
A R
T TEMPERATURERISE
60 0
C FM
70 0
90 0 10
00 11 00 12
00
14 00
16 00 18
00 20 00 22
00 24 00
C FM
FO R
M U
LA S
B TU
O U
TP U
T =
C FM
x 1.
08 x
R IS
E
R IS
E =
B TU
O U
TP U
T 1.
08
C FM
80 0
Temperature Rise
O ut
pu t
BT U
/h x
1 ,0
00
Fo rm
ul as
BT U
/h O
ut pu
t = C
FM x
1 .0
8 x
Ri se
Ri se
=
BT U
/H O
ut pu
t
CF M
x 1
.0 8
B TU
O ut
pu t
Vs . T
em pe
ra tu
re R
is e
Ch ar
t
10 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com PB
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 2021 Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA.
Wiring Diagram
W iri
ng is
s ub
je ct
to c
ha ng
e. A
lw ay
s re
fe r
to t
he w
iri ng
d ia
gr am
o r
th e
un it
fo r t
he m
os t u
p- to
-d at
e w
iri ng
.
W
ar n in g
Hi gh
V ol
ta ge
: Di
sc on
ne ct
a ll
po w
er b
ef or
e se
rv ic
in g
or i
ns ta
lli ng
t hi
s un
it. M
ul tip
le p
ow er
so
ur ce
s m ay
b e
pr es
en t.
Fa ilu
re to
d o
so m
ay c
au se
p ro
pe rt
y da
m ag
e, p
er so
na l i
nj ur
y, or
d ea
th .
CO LO
R C
O DE
S:
G R
G RE
EN SW
IT C
H (P
R ES
S. )
FI EL
D SP
LI CE
FI EL
D G
ND LO
W V
O LT
AG E
FI EL
D
RD R
ED G
Y G
RA Y
EQ UI
PM EN
T G
ND
IN TE
RN AL
T O
PR O
T. D
EV IC
E IN
TE G
RA TE
D C
O NT
RO L
PL UG
C O
NN EC
TI O
N
SW IT
C H
(T EM
P. )
PU P
UR PL
E
JU NC
TI O
N
PK P
IN K
H I V
O LT
AG E
(1 15
V)
LO W
V O
LT AG
E (2
4V )
BK B
LA C
K
BL B
LU E
W H
W H
IT E
O VE
RC UR
RE N
T
BR B
RO W
N
YL Y
EL LO
W
HI V
O LT
AG E
FI EL
D
O R
O RA
N G
E TE
R M
IN AL
IG NI
TE R
M ax
im um
A irf
lo w
O ut
pu t
To nn
ag e
M en
u To
nn ag
e Se
le ct
io n
Ai rfl
ow
1. 0
40 0
1. 1
44 0
1. 2
48 0
1. 3
52 0
1. 4
56 0
1. 5
60 0
1. 6
64 0
1. 7
68 0
1. 8
72 0
1. 9
76 0
2. 0
80 0
2. 1
84 0
2. 2
88 0
2. 3
92 0
2. 4
96 0
2. 5
10 00
2. 6
10 40
2. 7
10 80
2. 8
11 20
2. 9
11 60
3. 0
12 00
3. 1
12 40
3. 2
12 80
3. 3
13 20
3. 4
13 60
To nn
ag e
Se le
ct io
n Ai
rfl ow
3. 5
14 00
3. 6
14 40
3. 7
14 80
3. 8
15 20
3. 9
15 60
4. 0
16 00
4. 1
16 40
4. 2
16 80
4. 3
17 20
4. 4
17 60
4. 5
18 00
4. 6
18 40
4. 7
18 80
4. 8
19 20
4. 9
19 60
5. 0
20 00
5. 1
20 40
5. 2
20 80
5. 3
21 20
5. 4
21 60
5. 5
22 00
5. 6
22 40
5. 7
22 80
5. 8
23 20
5. 9
23 60
6. 0
24 00
M en
u N
av ig
at io
n an
d Se
le ct
io n
In st
ru ct
io ns
Us in
g Ph
on e
Ap pl
ic at
io n
ov er
B lu
et oo
th N
et w
or k:
1
) C on
ne ct
to th
e fu
rn ac
e (in
st ru
ct io
ns p
ro vi
de d
by
p
ho ne
d ur
in g
th e
co nn
ec tio
n Pr
oc es
s) .
2 ) S
el ec
t d es
ire d
se tti
ng s
m en
u
3 ) S
el ec
t i te
m th
at re
qu ire
s ad
ju st
m en
t a nd
m ak
e ne
ce ss
ar y
se le
ct io
n
4
) S ub
m it
C ha
ng es
Us in
g O
n- Bo
ar d
Pu sh
B ut
to ns
: 1
) U se
th e
Ri gh
t a nd
L ef
t B ut
to ns
to s
cr ol
l b et
w ee
n m
en us
2
) U se
th e
C en
te r B
ut to
n to
s el
ec t d
es ire
d m
en u
w he
n m
en u
c od
e is
s ho
w n
on 7-
se gm
en t d
is pl
ay s
3
) U se
th e
Le ft
an d
R ig
ht B
ut to
ns to
s cr
ol l t
hr ou
gh o
pt io
ns
w
ith in
th e
de si
re d
m en
u
(th e
di sp
la y
w ill
fla sh
w hi
le s
cr ol
lin g
th ro
ug h
op tio
ns fo
r
se
le ct
io n)
4
) U se
th e
C en
te r B
ut to
n to
s el
ec t t
he d
is pl
ay ed
o pt
io n
(w he
n se
le ct
ed th
e di
sp la
y w
ill st
op fl
as hi
ng )
5
) U se
th e
C en
te r B
ut to
n to
fi na
liz e
se le
ct io
n an
d re
tu rn
to
th
e m
ai n
m en
u Ai
rfl ow
S et
tin gs
In st
ru ct
io ns
1) F
or n
on -c
om m
un ic
at in
g in
st al
la tio
ns , s
el ec
t t he
ty pe
of
u ni
t i ns
ta lle
d
in th
e O
dS m
en u
(1 AC
= s
in gl
e- st
ag e
ai r c
on di
tio ne
r,
1H P
= sin
gl e-
st ag
e he
at p
um p,
2 AC
= 2
s ta
ge a
ir co
nd iti
on er
,
2H P
= 2
st ag
e he
at p
um p)
D ef
au lt
= O
FF (n
o ou
td oo
r u ni
t). 2)
T he
to nn
ag e
m en
u M
us t b
e us
ed to
s el
ec t C
oo lin
g/ He
at P
um p
Ai
rfl ow
(n on
-c om
m un
ic at
in g
in st
al la
tio n)
. To
nn ag
e se
le ct
io n
op tio
ns
an d
co rre
sp on
di ng
a irf
lo w
C FM
c an
b e
fo un
d to
th e
rig ht
. [A
irf lo
w =
T on
na ge
S el
ec tio
n x
40 0]
D ef
au lt
se le
ct io
n is
6. 0
to
ns .
3) [O
pt io
na l]
Us e
th e
C oo
lin g
Tr im
M en
u (C
tF ) t
o ad
ju st
th e
co
ol in
g ai
rfl ow
fr om
-1 0%
to +
10 %
(2 %
in cr
em en
ts ).
Th is
a pp
lie s
fo r 2
s ta
ge c
om m
un ic
at in
g ou
td oo
r u ni
ts a
nd s
in gl
e
o r 2
s ta
ge n
on -c
om m
un ic
at in
g ou
td oo
r u ni
ts .
4 ) [
O pt
io na
l] Us
e th
e H
ea tin
g Tr
im M
en u
(H tF
) t o
ad ju
st th
e
h ea
t p um
p ai
rfl ow
fr om
-1 0%
to +
10 %
(2 %
in cr
em en
ts ).
T
hi s
ap pl
ie s
fo r 2
s ta
ge c
om m
un ic
at in
g ou
td oo
r u ni
ts a
nd s
in gl
e or
2 s
ta ge
n on
-c om
m un
ic at
in g
ou td
oo r u
ni ts
. 5
) [ O
pt io
na l]
Us e
th e
C on
st an
t F an
M en
u (F
SD ) t
o se
le ct
th e
p er
ce nt
ag e
of m
ax im
um a
irf lo
w fo
r c on
tin uo
us fa
n 6
) [ O
pt io
na l]
Us e
th e
C oo
lin g
Ai rfl
ow P
ro fil
e M
en u
(C AP
) t o
s
el ec
t b et
w ee
n 5
co ol
in g
ai rfl
ow p
ro file
s. P
ro file
o pt
io ns
1 -4
a re
li
st ed
a bo
ve (o
pt io
n 5
is a
dj us
ta bl
e) . S
ee in
st al
la tio
n m
an ua
l f or
fu rth
er
d
et ai
ls
01 40
F0 26
16 -A
NO TE
S: .
1. S
ET H
EA T
AN TI
C IP
AT O
R O
N RO
O M
T H
ER M
O ST
AT A
T 0.
7 AM
PS .
2. M
AN UF
AC TU
RE R
'S S
PE CI
FI ED
R EP
LA CE
M EN
T PA
R TS
M US
T BE
US
ED W
H EN
S ER
VI CI
NG 3.
IF A
N Y
O F
TH E
O RI
G IN
AL W
IR E
AS S
UP PL
IE D
W IT
H T
H E
F UR
NA CE
M US
T BE
R EP
LA CE
D,
A T
L EA
ST 1
05 v C
. U SE
C O
PP ER
C O
ND U
C TO
RS O
NL Y.
4. U
NI T
M US
T BE
P ER
M AN
EN TL
Y G
RO UN
DE D
AN D
CO N
FO R
M T
O N
.E .C
. A N
D LO
CA L
CO DE
S.
3 T
on 6
0k B
TU H
= 1
,4 00
C FM
3 T
on 8
0k B
TU H
= 1
,6 50
C FM
4 T
on M
od el
s =
1, 76
0 CF
M 5
T on
M od
el s
= 2,
20 0
CF M
TO +
VD C
TO M
IC RO
TO R G
ND (4
)
+ VD
C (1
)
RX (2
)
TX (3
) CI
RC UL
AT O
R
IN DO
O R
AI R
BL W
R
RD G
Y
PR O
PE R
LY P
O LA
R IZ
ED
G ND
PR O
TE CT
IO N
DE VI
CE
BU RN
ER C
O M
PA RT
M EN
T
PO W
ER S
UP PL
Y W
IT H
LI N
E
RD
TO
C
BK
RD
D IS
C O
NN EC
T PO
W ER FL
AM E
SE N
SO R
IN TE
G R
AT ED
C O
N TR
O L
M O
DU LE
PO W
ER B
EF O
R E
BROR BL
M VC
(8 )
M
EC M
M TR
H AR
N ES
S
NO
24 V
AC AU
TO R
ES ET
P R
IM AR
Y LI
M IT
C O
NT RO
L
BE FO
R E
SE R
VI C
IN G
.
PS 1
(2 )
3
BK
BK
11 5
VA C
/ 1
BL O
W ER
C O
M PA
RT M
EN T
24
BK
BK
IN DU
CE D
DR AF
T BL
O W
ER
C
11 5
VA C
IN D
UC TO
R C
O IL
(O N
SO M
E M
O D
EL S)
YL
G ND
/6
0 H
Z PO
W ER
S U
PP LY
W IT
H TO
1 15
VA C
/ 1
INTEGRATED CONTROL MODULE
G ND
2
W H
H O
T SU
RF AC
E IG
N IT
ER
M VH
(1 4)
NE UT
RA L
DO O
R SW
IT CH
LO W
F IR
E PR
ES S.
SW IT
C H
4
3 2
CHASSIS GROUND
W H
VA C
G ND
2 CI
RC U
IT CO
NN EC
TO R
O VE
RC U
RR EN
T
PS O
(7 )
C
DI SC
O NN
EC T HI
G H
FI RE
PR ES
S. S
W TI
CHIN DO
O R
AI R
CI R
CU LA
TO R
BL W
R
/6
0 HZ
N
BK
M AN
UA L
R ES
ET R
O LL
O U
T LI
M IT
C O
NT RO
LS
IN D
LO
40 V
A TR
AN SF
O RM
ER
AU TO
R ES
ET A
UX IL
IA R
Y LI
M IT
CO NT
RO LS
(T W
O O
N S
O M
E M
O D
EL S)
O R
C IR
CU LA
TO R
BL O
W ER
R
G ND
JU N
CT IO
N B
O X
N EU
TR AL
LI N
E
BK
4
PO LA
R IZ
ED A
ND
HI
FS
2
DI SC
O N
NE CT
BR
BL
HI G
H FI
RE PR
ES SU
R E
SW IT
CH
W
NO
M VL
(1 3)
SE R
VI C
IN G
. W IR
IN G
W H
BR
ID B
LO W
ER T
W O
-S TA
G E
PR ES
SU RE
SW IT
CH A
SS EM
BL Y
5
G ND
(5 )
BK
IN D
HI
IG N
PK
HL O
(1 0)
PU
L
W H
M AN
UA L
R ES
ET R
O LL
O UT
L IM
IT CO
NT RO
LS
Y
EL EC
TR O
N IC
AI R
C LE
AN ER
BL
NE UT
RA L
1
HL I (
1)
W HAU
TO R
ES ET
P RI
M AR
Y LI
M IT
C O
NT RO
LNO
WH
M U
ST B
E PR
O PE
R LY
OR
O VE
R CU
RR EN
T PR
O TE
C TI
O N
D EV
IC E
GR
G RO
UN D
ED .
W AR
N IN
G :
W H
11 5
NE UT
RA L
JUNCTION BOX
G ND
1
AN D
G R
O UN
D ED
.
BK
G AS
VA LV
E
24V THERMOSTAT CONNECTIONS
PU
IN DU
C TO
R C
O IL
(O N
SO M
E M
O DE
LS )
TH (4
)
C
C
1
TO U
N IT
M U
ST B
E
VA C
G
C
TR (1
1)
G R
HO T
SU RF
AC E
IG N
IT ER
FL AM
E SE
NS O
R
PS 2
(1 2)
LO W
F IR
E PR
ES SU
R E
SW IT
CH 1
INTEGRATED CONTROL MODULE
L
BR
3
W IR
IN G
T O
U N
IT
N O
N EU
TR AL
N
WH
40 V
A TR
AN SF
O RM
ER
ID BL
W R
TO M IC
R O
W AR
N IN
G :D
IS C
O NN
EC T
BL
AU TO
R ES
ET AU
XI LI
AR Y
LI M
IT CO
NT R
O L
(T W
O O
N SO
M E
M O
DE LS
)
FU SE
3 A
2
24 V
3 A
BL
12
2
4
5 CIRCUIT CONNECTOR
4 CIRCUIT MOTOR CONNECTOR
4
1
FU SE
15 6 5LI N
E
2
RD
2
9
14
3
1
BR
11
EAC
CONTROL MODULE
8
WH
BL
BL
13
3
5
BR
7
1
3
FS
4
YL
OR
DI AG
NO ST
IC LE
D' S
PK
10
GR
RD
BL
BK
EA C
BR
O R
RO LL
O UT
S W
IT CH
IN (6
)
AU X
IN (3
)
PU
W H
W H
BK
NEUTRAL
TH ER
M O
ST AT
C R
1 2
D E
Y G
Related manuals for Goodman GCVC80 User's Manual
Manualsnet FAQs
If you want to find out how the GCVC80 Goodman works, you can view and download the Goodman GCVC80 User's Manual on the Manualsnet website.
Yes, we have the User's Manual for Goodman GCVC80 as well as other Goodman manuals. All you need to do is to use our search bar and find the user manual that you are looking for.
The User's Manual should include all the details that are needed to use a Goodman GCVC80. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.
The best way to navigate the Goodman GCVC80 User's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.
This Goodman GCVC80 User's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.
You can download Goodman GCVC80 User's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.
To be able to print Goodman GCVC80 User's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Goodman GCVC80 User's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.