Goodman GCVC80 User's Manual PDF

1 of 10
1 of 10

Summary of Content for Goodman GCVC80 User's Manual PDF

SS-GMVC80/GCVC80 www.goodmanmfg.com 12/21 Supersedes 12/21

Two-Stage, Variable-Speed ECM Gas Furnace

80% AFUE

GMVC80(A) / GCVC80(A) Heating Input: 60,000100,000 BTU/h

Contents Nomenclature ........................................ 2 Product Specifications ........................... 3 Dimensions ............................................ 5 Airflow Data ........................................... 7 Accessories ............................................ 8 Wiring Diagram ................................... 10

Standard Features Integrated communicating ComfortBridge technology Two-stage gas valve provides quiet,

economical heating Commissioning and diagnostics via on board

Bluetooth with the CoolCloud phone and tablet application

Efficient and quiet variable-speed ECM circulator motor gently ramps up or down according to heating or cooling demand

SureStart Silicon Nitride igniter designed for long igniter life

Self-diagnostic control board with constant memory fault code history output to a triple 7-segment display

Low constant fan speed circulates air throughout the home

Quiet, two-speed induced draft blower California Low NOx emissions-compliant

models available Can no longer be installed in Californias

South Coast Air Quality Management District (SCAQMD) on or after October 1, 2019.

AHRI Certified; ETL Listed

Cabinet Features Fully insulated, heavy-gauge steel cabinet

with durable baked-enamel finish Multi-position installation:

GMVC80: upflow, horizontal left or right GCVC80: downflow, horizontal left or right

Removable bottom for side- or bottom-return applications

Convenient left or right connection for gas/electric service

Cabinet air leakage 2% Coil and furnace fit flush

for most installations

* Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Qubec.

2 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 3

Nomenclature

G M V C 80 040 4 C * **

1 2 3 4 5,6 7,8,9 10 11 12 13,14

Brand Engineering

G - Goodman Brand Major /Minor Revisions * Not used for inventory control.

Configuration NOx

M - Upflow/Horizontal N - Natural Gas

C - Downflow/Horizontal X - Low NOx

Motor Cabinet Width

V - Variable Speed ECM / ComfortBridge A - 14" C - 21"

E - Multi-Speed ECM S - Single Speed B - 17" D - 24"

Gas Valve Maximum CFM

M - Modulating S - Single Stage 2 - 800 CFM 4 - 1600 CFM

C - Two Stage 3 - 1200 CFM 5 - 2000 CFM

AFUE MBTU/h

80 - 80% AFUE 040 - 40,000 BTU/h 100 - 100,000 BTU/h

060 - 60,000 BTU/h 120 - 120,000 BTU/h

080 - 80,000 BTU/h

2 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 3

Specifications

GMVC80 0603B*A

GMVC80 0604B*A

GMVC80 0803B*A

GMVC80 0804C*A

GMVC80 0805C*A

GMVC80 0805D*A

GMVC80 1005C*A

Heating Capacity

High Fire Input (BTU/h) 60,000 60,000 80,000 80,000 80,000 80,000 100,000

High Fire Output (BTU/h) :

Natural Gas 48,000 48,000 64,000 64,000 64,000 64,000 80,000

LP Gas 48,000 48,000 64,000 64,000 64,000 64,000 80,000

Low Fire Input (BTU/h) 42,000 42,000 56,000 56,000 56,000 56,000 70,000

Low Fire Output (BTU/h) :

Natural Gas 33,600 33,600 44,800 44,800 44,800 44,800 56,000

LP Gas 33,600 33,600 44,800 44,800 44,800 44,800 56,000

AFUE 80 80 80 80 80 80 80

Available AC @ 0.5 ESP 1.5 - 3.0 1.5 - 4.0 1.5 - 3.0 3.0 - 4.0 2.0 - 5.0 2.5 - 5.0 2.0 - 5.0

Temperature Rise Range ( F) 15-45 / 15-45 20-50 / 20-50 30-60 / 35-65 25-55 / 20-50 20-50 / 20-50 20-50 / 30-60 25-55 / 25-55

Circulator Blower

Size (D x W) 10 x 8 10 x 8 10 x 8 11" x 10" 10 x 10 11" x 10" 10 x 10

Horsepower - RPM 1/2 3/4 1/2 1/2 3/4 3/4 3/4

Speed Variable ECM Variable ECM Variable ECM Variable ECM Variable ECM Variable ECM Variable ECM

Vent Diameter 4 4 4 4 4 4 4

No. of Burners 3 3 4 4 4 4 5

Electrical Data

Min. Circuit Ampacity 7.75 10.6 7.75 7.75 10.6 10.6 10.6

Max. Overcurrent Device (amps)4 15 15 15 15 15 15 15

Ship Weight (lbs) 105 107 110 118 121 129 124

Natural Gas BTU/h; for altitudes above from 0 to 4,500 above sea level, reduce input rating 4% for each 1,000 above 4,500 altitude. Low-fire rate is 70% of high-fire rate. DOE AFUE based upon Isolated Combustion System (ICS) Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs

will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all

existing local codes.

4 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 5

Specifications

GCVC80 0603B*A

GCVC80 0803B*A

GCVC80 0805C*A

GCVC80 1005C*A

Heating Capacity

High Fire Input (BTU/h) 60,000 80,000 80,000 100,000

High Fire Output (BTU/h)

Natural Gas 48,000 64,000 64,000 80,000

LP Gas 48,000 64,000 64,000 80,000

Low Fire Input (BTU/h) 42,000 56,000 56,000 70,000

Low Fire Output (BTU/h)

Natural Gas 33,600 44,800 44,800 56,000

LP Gas 33,600 44,800 44,800 56,000

AFUE 80 80 80 80

Available AC @ 0.5 ESP 1.5 - 3.0 1.5 - 3.0 2.0 - 5.0 2.0 - 5.0

Temperature Rise Range ( F) 25-55 / 40-70 30-60 / 30-60 25-55 / 30-60 20-50 / 25-55

Circulator Blower

Size (D x W) 10 x 8 10 x 8 10 x 10 10 x 10

Horsepower - RPM 1/2 1/2 3/4 3/4

Speed Variable ECM Variable ECM Variable ECM Variable ECM

Vent Diameter 4 4 4 4

No. of Burners 3 4 4 5

Electrical Data

Min. Circuit Ampacity 7.75 7.75 10.6 10.6

Max. Overcurrent Device (amps) 15 15 15 15

Ship Weight (lbs) 105 109 125 129 Natural Gas BTU/h; for altitudes above from 0 to 4,500 above sea level, reduce input rating 4% for each 1,000 above 4,500 altitude. Low-fire rate is 70% of high-

fire rate. DOE AFUE based upon Isolated Combustion System (ICS) Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes.

Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit

breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.

4 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 5

Minimum Clearances to Combustible Materials

Sides Rear Front Bottom Vent

Top SW B

1 0 3 C 6 1 1

C = If placed on combustible floor, the floor MUST be wood ONLY.

Notes: For servicing or cleaning, a 24 front clearance is recommended. Unit connections (electrical, flue, and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. Refer to the appropriate USA and Canadian codes:

In the USA: the National Fuel Gas Code NFPA 54 / ANSI Z223.1 In Canada: the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2

GMVC80 Dimensions

Model Dimensions Heights

W D H A B

GMVC800603B** 17 28 33" 17 16

GMVC800604B** 17 28 33" 17 16

GMVC800803B** 17 28 33" 17 16

GMVC800804C** 21 28 33" 21 19

GMVC800805C** 21 28 33" 21 19

GMVC800805D** 24 28" 33" 24 23"

GMVC801005C** 21 28 33" 21 19

28

A B

1

33

23516

1716

13

20

27 Alt. Gas Inlet

Alt. High Voltage

Alt. Low Voltage

Alternate Gas Inlet

High-Voltage Inlet

Low-Voltage Inlet

Alt. Flue Outlet Horizontal Left

19

23

15

6 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 7

GCVC80 Dimensions

A

B

High-Voltage Electrical

Low-Voltage Electrical

Gas Inlet

11

18

19

33

28

Minimum Clearances to Combustible Materials

Sides Rear Front Vent

Top SW B

1 0 3 6 1 1

Approved for line contact in the horizontal position. 24 clearance for serviceability recommended. Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables outlined in the

Installation Manual for additional venting requirements.

Model Dimensions Heights

W D H A B

GCVC800603B** 17 28 33" 17 16

GCVC800803B** 17 28 33" 17 16

GCVC800805C** 21 28 33" 21 19

GCVC801005C** 21 28 33" 21 19

6 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 7

Airflow Data

MODEL/TEMP RISE RANGE (MID RISE)

GMVC800803B*A* 30-60 (45)

GMVC800804C*A* 25-55 (40)

GMVC800805C*A* 20-50 (35)

GMVC800805D*A* 20-50 (35)

GMVC801005C*A* 25-55 (40)

CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE

Recommended cfm for high heat / expected temperature rise 1330 45 1400 42 1700 35 1700 35 1850 40

Lowest recommended cfm for hi heat / expected temperature rise 980 60 1090 54 1175 50 1175 50 1350 55

Maximum cfm for hi heat / expected temperature rise 1400 42 1760 34 2200 27 2200 27 2200 34

NOTE: Low Heat CFM = High Heat CFM X .7. Low Heat Temperature Rise Is Expected to Equal High Heat Temparatue Rise 5% 0140F02402-A

MODEL/TEMP RISE RANGE (MID RISE)

GCVC800603BXA* 25-55 (40)

GCVC800603BXA* 30-60 (45)

GCVC800805CXA* 25-55 (40)

GCVC801005CXA* 20-50 (35)

GMVC800603B*A* 15-45 (30)

GMVC800604B*A* 20-50 (35)

CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE

Recommended cfm for high heat / expected temperature rise 1100 40 1325 45 1470 40 2090 35 1400 32 1275 35

Lowest recommended cfm for hi heat / expected temperature rise 810 55 990 60 1070 55 1475 50 980 45 890 50

Maximum cfm for hi heat / expected temperature rise 1400 32 1400 42 2200 27 2200 34 1400 32 1760 25

NOTE: Low Heat CFM = High Heat CFM X .7. Low Heat Temperature Rise Is Expected to Equal High Heat Temparatue Rise 5% 0140F02402-A

GCVC800603BXA*, GCVC800803BXA* GMCV800603B*A*, GMVC800803B*A*

Cooling Speed ( @ .1 - .8 w.c. ESP)

GMVC800604B*A* GMVC800804C*A*

Cooling Speed ( @ .1 - .8 w.c. ESP)

Tons High-Stage Low-Stage CFM Tons High-Stage Low-Stage

CFM 1.5 600 420 2 800 560 2 800 560 2.5 1,000 700

2.5 1,000 700 3 1,200 840 3 1,200 840 4 1,600 1120

MAX 1,400 MAX 1,760

GCVC800805CXA* GCVC801005CXA*

Cooling Speed ( @ .1 - .8 w.c. ESP)

GMVC800805C*A*, GMVC800805D*A* GMVC801005C*A*

Cooling Speed ( @ .1 - .8 w.c. ESP)

Tons High-Stage Low-Stage CFM Tons High-Stage Low-Stage

CFM 2 800 560 2 800 560 3 1,200 840 3 1,200 840 4 1,600 1,120 4 1,600 1,120 5 2,000 1,400 5 2,000 1,400

MAX 2,000 MAX 2,200

All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable. Do not operate above .5 w.c. ESP in heating mode. Operating CFM between .5 and .8 w.c. is tabulated for cooling purposes only.

8 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 9

Airflow Data (cont.)

GCVC8 Minimum Filter Sizes

Model # GCVC800603BX, GCVC80803BX GCVC800805CX GCVC801005CX

Filter Size (in) (2) 10 x 20 or (1) 16 x 25 (Top Return) (2) 14 x 20 or (1) 20 x 25 (Top Return)

Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located. Use 2 - 16 X 25 filters on side returns or 20 X 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity.

GMVC8 Minimum Filter Sizes

Model # GMVC800604B*, GMVC800603B*, GMVC800803B*

GMVC800805C*, GMVC800804C*, GMVC800805D* GMVC801005C*

Filter Size (in) (1) 16 x 25 (Side or Bottom) (1) 16 x 25 (Side or Bottom) (2) 16 x 25 (Side) or (1) 20 x 25 (Bottom)

Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located. Use 2 - 16 X 25 filters on side returns or 20 X 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity.

GMVC Continuous Fan Speeds

Model Furnace Maximum CFM

Continuous Fan Speed

GMVC800603B*A 1400 350 - 1400

GMVC800604B*A 1760 440 - 1760

GMVC800803B*A 1400 350 - 1400

GMVC800804C*A 1760 440 - 1760

GMVC800805C*A 2200 550 - 2200

GMVC800805D*A 2200 550 - 2200

GMVC801005C*A 2200 550 - 2200

GCVC Continuous Fan Speeds

Model Furnace Maximum CFM

Continuous Fan Speed

GCVC800603BXA* 1,400 350-1,400

GCVC800803BXA* 1,400 350-1,400

GCVC800805CXA* 2,200 550-2,200

GCVC801005CXA* 2,200 550-2,200

Model Description GMVC80 0603B*

GMVC80 0604B*

GMVC80 0803B*

GMVC80 0804C*

GMVC80 0805C*

GMVC80 0805D*

GMVC80 1005C*

AFE18-60A Fossil Fuel (Dual Fuel) Kit HA-02 High-Altitude Natural Gas Kit LPLP03 Low LP Gas Pressure Switch LPM-06 LP Conversion Kits

Model Description GCVC80 0603B*

GCVC80 0803B*

GCVC80 0805C*

GCVC80 1005C*

SBT17 Downflow Sub-Base 17.5" SBT21 Downflow Sub-Base 21" AFE18-60A Fossil Fuel (Dual Fuel) Kit HA-02 High-Altitude Natural Gas Kit LPLP03 Low LP Gas Pressure Switch LPM-06 LP Conversion Kits

Accessories

8 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com 9

Temperature Rise Range Chart

30 40

50 60

70 80

90 11

0 12

0 10

0 13

0 14

0 15

0

10 0

90 80 70 60 50 40 30 20 10

O U

TP U

T B

TU /H

R x

10 00

B TU

O U

TP U

T vs

TE M

P E

R AT

U R

E R

IS E

C H

A R

T TEMPERATURERISE

60 0

C FM

70 0

90 0 10

00 11 00 12

00

14 00

16 00 18

00 20 00 22

00 24 00

C FM

FO R

M U

LA S

B TU

O U

TP U

T =

C FM

x 1.

08 x

R IS

E

R IS

E =

B TU

O U

TP U

T 1.

08

C FM

80 0

Temperature Rise

O ut

pu t

BT U

/h x

1 ,0

00

Fo rm

ul as

BT U

/h O

ut pu

t = C

FM x

1 .0

8 x

Ri se

Ri se

=

BT U

/H O

ut pu

t

CF M

x 1

.0 8

B TU

O ut

pu t

Vs . T

em pe

ra tu

re R

is e

Ch ar

t

10 www.goodmanmfg.com SS-GMVC80/GCVC80 SS-GMVC80/GCVC80 www.goodmanmfg.com PB

Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 2021 Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA.

Wiring Diagram

W iri

ng is

s ub

je ct

to c

ha ng

e. A

lw ay

s re

fe r

to t

he w

iri ng

d ia

gr am

o r

th e

un it

fo r t

he m

os t u

p- to

-d at

e w

iri ng

.

W

ar n in g

Hi gh

V ol

ta ge

: Di

sc on

ne ct

a ll

po w

er b

ef or

e se

rv ic

in g

or i

ns ta

lli ng

t hi

s un

it. M

ul tip

le p

ow er

so

ur ce

s m ay

b e

pr es

en t.

Fa ilu

re to

d o

so m

ay c

au se

p ro

pe rt

y da

m ag

e, p

er so

na l i

nj ur

y, or

d ea

th .

CO LO

R C

O DE

S:

G R

G RE

EN SW

IT C

H (P

R ES

S. )

FI EL

D SP

LI CE

FI EL

D G

ND LO

W V

O LT

AG E

FI EL

D

RD R

ED G

Y G

RA Y

EQ UI

PM EN

T G

ND

IN TE

RN AL

T O

PR O

T. D

EV IC

E IN

TE G

RA TE

D C

O NT

RO L

PL UG

C O

NN EC

TI O

N

SW IT

C H

(T EM

P. )

PU P

UR PL

E

JU NC

TI O

N

PK P

IN K

H I V

O LT

AG E

(1 15

V)

LO W

V O

LT AG

E (2

4V )

BK B

LA C

K

BL B

LU E

W H

W H

IT E

O VE

RC UR

RE N

T

BR B

RO W

N

YL Y

EL LO

W

HI V

O LT

AG E

FI EL

D

O R

O RA

N G

E TE

R M

IN AL

IG NI

TE R

M ax

im um

A irf

lo w

O ut

pu t

To nn

ag e

M en

u To

nn ag

e Se

le ct

io n

Ai rfl

ow

1. 0

40 0

1. 1

44 0

1. 2

48 0

1. 3

52 0

1. 4

56 0

1. 5

60 0

1. 6

64 0

1. 7

68 0

1. 8

72 0

1. 9

76 0

2. 0

80 0

2. 1

84 0

2. 2

88 0

2. 3

92 0

2. 4

96 0

2. 5

10 00

2. 6

10 40

2. 7

10 80

2. 8

11 20

2. 9

11 60

3. 0

12 00

3. 1

12 40

3. 2

12 80

3. 3

13 20

3. 4

13 60

To nn

ag e

Se le

ct io

n Ai

rfl ow

3. 5

14 00

3. 6

14 40

3. 7

14 80

3. 8

15 20

3. 9

15 60

4. 0

16 00

4. 1

16 40

4. 2

16 80

4. 3

17 20

4. 4

17 60

4. 5

18 00

4. 6

18 40

4. 7

18 80

4. 8

19 20

4. 9

19 60

5. 0

20 00

5. 1

20 40

5. 2

20 80

5. 3

21 20

5. 4

21 60

5. 5

22 00

5. 6

22 40

5. 7

22 80

5. 8

23 20

5. 9

23 60

6. 0

24 00

M en

u N

av ig

at io

n an

d Se

le ct

io n

In st

ru ct

io ns

Us in

g Ph

on e

Ap pl

ic at

io n

ov er

B lu

et oo

th N

et w

or k:

1

) C on

ne ct

to th

e fu

rn ac

e (in

st ru

ct io

ns p

ro vi

de d

by

p

ho ne

d ur

in g

th e

co nn

ec tio

n Pr

oc es

s) .

2 ) S

el ec

t d es

ire d

se tti

ng s

m en

u

3 ) S

el ec

t i te

m th

at re

qu ire

s ad

ju st

m en

t a nd

m ak

e ne

ce ss

ar y

se le

ct io

n

4

) S ub

m it

C ha

ng es

Us in

g O

n- Bo

ar d

Pu sh

B ut

to ns

: 1

) U se

th e

Ri gh

t a nd

L ef

t B ut

to ns

to s

cr ol

l b et

w ee

n m

en us

2

) U se

th e

C en

te r B

ut to

n to

s el

ec t d

es ire

d m

en u

w he

n m

en u

c od

e is

s ho

w n

on 7-

se gm

en t d

is pl

ay s

3

) U se

th e

Le ft

an d

R ig

ht B

ut to

ns to

s cr

ol l t

hr ou

gh o

pt io

ns

w

ith in

th e

de si

re d

m en

u

(th e

di sp

la y

w ill

fla sh

w hi

le s

cr ol

lin g

th ro

ug h

op tio

ns fo

r

se

le ct

io n)

4

) U se

th e

C en

te r B

ut to

n to

s el

ec t t

he d

is pl

ay ed

o pt

io n

(w he

n se

le ct

ed th

e di

sp la

y w

ill st

op fl

as hi

ng )

5

) U se

th e

C en

te r B

ut to

n to

fi na

liz e

se le

ct io

n an

d re

tu rn

to

th

e m

ai n

m en

u Ai

rfl ow

S et

tin gs

In st

ru ct

io ns

1) F

or n

on -c

om m

un ic

at in

g in

st al

la tio

ns , s

el ec

t t he

ty pe

of

u ni

t i ns

ta lle

d

in th

e O

dS m

en u

(1 AC

= s

in gl

e- st

ag e

ai r c

on di

tio ne

r,

1H P

= sin

gl e-

st ag

e he

at p

um p,

2 AC

= 2

s ta

ge a

ir co

nd iti

on er

,

2H P

= 2

st ag

e he

at p

um p)

D ef

au lt

= O

FF (n

o ou

td oo

r u ni

t). 2)

T he

to nn

ag e

m en

u M

us t b

e us

ed to

s el

ec t C

oo lin

g/ He

at P

um p

Ai

rfl ow

(n on

-c om

m un

ic at

in g

in st

al la

tio n)

. To

nn ag

e se

le ct

io n

op tio

ns

an d

co rre

sp on

di ng

a irf

lo w

C FM

c an

b e

fo un

d to

th e

rig ht

. [A

irf lo

w =

T on

na ge

S el

ec tio

n x

40 0]

D ef

au lt

se le

ct io

n is

6. 0

to

ns .

3) [O

pt io

na l]

Us e

th e

C oo

lin g

Tr im

M en

u (C

tF ) t

o ad

ju st

th e

co

ol in

g ai

rfl ow

fr om

-1 0%

to +

10 %

(2 %

in cr

em en

ts ).

Th is

a pp

lie s

fo r 2

s ta

ge c

om m

un ic

at in

g ou

td oo

r u ni

ts a

nd s

in gl

e

o r 2

s ta

ge n

on -c

om m

un ic

at in

g ou

td oo

r u ni

ts .

4 ) [

O pt

io na

l] Us

e th

e H

ea tin

g Tr

im M

en u

(H tF

) t o

ad ju

st th

e

h ea

t p um

p ai

rfl ow

fr om

-1 0%

to +

10 %

(2 %

in cr

em en

ts ).

T

hi s

ap pl

ie s

fo r 2

s ta

ge c

om m

un ic

at in

g ou

td oo

r u ni

ts a

nd s

in gl

e or

2 s

ta ge

n on

-c om

m un

ic at

in g

ou td

oo r u

ni ts

. 5

) [ O

pt io

na l]

Us e

th e

C on

st an

t F an

M en

u (F

SD ) t

o se

le ct

th e

p er

ce nt

ag e

of m

ax im

um a

irf lo

w fo

r c on

tin uo

us fa

n 6

) [ O

pt io

na l]

Us e

th e

C oo

lin g

Ai rfl

ow P

ro fil

e M

en u

(C AP

) t o

s

el ec

t b et

w ee

n 5

co ol

in g

ai rfl

ow p

ro file

s. P

ro file

o pt

io ns

1 -4

a re

li

st ed

a bo

ve (o

pt io

n 5

is a

dj us

ta bl

e) . S

ee in

st al

la tio

n m

an ua

l f or

fu rth

er

d

et ai

ls

01 40

F0 26

16 -A

NO TE

S: .

1. S

ET H

EA T

AN TI

C IP

AT O

R O

N RO

O M

T H

ER M

O ST

AT A

T 0.

7 AM

PS .

2. M

AN UF

AC TU

RE R

'S S

PE CI

FI ED

R EP

LA CE

M EN

T PA

R TS

M US

T BE

US

ED W

H EN

S ER

VI CI

NG 3.

IF A

N Y

O F

TH E

O RI

G IN

AL W

IR E

AS S

UP PL

IE D

W IT

H T

H E

F UR

NA CE

M US

T BE

R EP

LA CE

D,

A T

L EA

ST 1

05 v C

. U SE

C O

PP ER

C O

ND U

C TO

RS O

NL Y.

4. U

NI T

M US

T BE

P ER

M AN

EN TL

Y G

RO UN

DE D

AN D

CO N

FO R

M T

O N

.E .C

. A N

D LO

CA L

CO DE

S.

3 T

on 6

0k B

TU H

= 1

,4 00

C FM

3 T

on 8

0k B

TU H

= 1

,6 50

C FM

4 T

on M

od el

s =

1, 76

0 CF

M 5

T on

M od

el s

= 2,

20 0

CF M

TO +

VD C

TO M

IC RO

TO R G

ND (4

)

+ VD

C (1

)

RX (2

)

TX (3

) CI

RC UL

AT O

R

IN DO

O R

AI R

BL W

R

RD G

Y

PR O

PE R

LY P

O LA

R IZ

ED

G ND

PR O

TE CT

IO N

DE VI

CE

BU RN

ER C

O M

PA RT

M EN

T

PO W

ER S

UP PL

Y W

IT H

LI N

E

RD

TO

C

BK

RD

D IS

C O

NN EC

T PO

W ER FL

AM E

SE N

SO R

IN TE

G R

AT ED

C O

N TR

O L

M O

DU LE

PO W

ER B

EF O

R E

BROR BL

M VC

(8 )

M

EC M

M TR

H AR

N ES

S

NO

24 V

AC AU

TO R

ES ET

P R

IM AR

Y LI

M IT

C O

NT RO

L

BE FO

R E

SE R

VI C

IN G

.

PS 1

(2 )

3

BK

BK

11 5

VA C

/ 1

BL O

W ER

C O

M PA

RT M

EN T

24

BK

BK

IN DU

CE D

DR AF

T BL

O W

ER

C

11 5

VA C

IN D

UC TO

R C

O IL

(O N

SO M

E M

O D

EL S)

YL

G ND

/6

0 H

Z PO

W ER

S U

PP LY

W IT

H TO

1 15

VA C

/ 1

INTEGRATED CONTROL MODULE

G ND

2

W H

H O

T SU

RF AC

E IG

N IT

ER

M VH

(1 4)

NE UT

RA L

DO O

R SW

IT CH

LO W

F IR

E PR

ES S.

SW IT

C H

4

3 2

CHASSIS GROUND

W H

VA C

G ND

2 CI

RC U

IT CO

NN EC

TO R

O VE

RC U

RR EN

T

PS O

(7 )

C

DI SC

O NN

EC T HI

G H

FI RE

PR ES

S. S

W TI

CHIN DO

O R

AI R

CI R

CU LA

TO R

BL W

R

/6

0 HZ

N

BK

M AN

UA L

R ES

ET R

O LL

O U

T LI

M IT

C O

NT RO

LS

IN D

LO

40 V

A TR

AN SF

O RM

ER

AU TO

R ES

ET A

UX IL

IA R

Y LI

M IT

CO NT

RO LS

(T W

O O

N S

O M

E M

O D

EL S)

O R

C IR

CU LA

TO R

BL O

W ER

R

G ND

JU N

CT IO

N B

O X

N EU

TR AL

LI N

E

BK

4

PO LA

R IZ

ED A

ND

HI

FS

2

DI SC

O N

NE CT

BR

BL

HI G

H FI

RE PR

ES SU

R E

SW IT

CH

W

NO

M VL

(1 3)

SE R

VI C

IN G

. W IR

IN G

W H

BR

ID B

LO W

ER T

W O

-S TA

G E

PR ES

SU RE

SW IT

CH A

SS EM

BL Y

5

G ND

(5 )

BK

IN D

HI

IG N

PK

HL O

(1 0)

PU

L

W H

M AN

UA L

R ES

ET R

O LL

O UT

L IM

IT CO

NT RO

LS

Y

EL EC

TR O

N IC

AI R

C LE

AN ER

BL

NE UT

RA L

1

HL I (

1)

W HAU

TO R

ES ET

P RI

M AR

Y LI

M IT

C O

NT RO

LNO

WH

M U

ST B

E PR

O PE

R LY

OR

O VE

R CU

RR EN

T PR

O TE

C TI

O N

D EV

IC E

GR

G RO

UN D

ED .

W AR

N IN

G :

W H

11 5

NE UT

RA L

JUNCTION BOX

G ND

1

AN D

G R

O UN

D ED

.

BK

G AS

VA LV

E

24V THERMOSTAT CONNECTIONS

PU

IN DU

C TO

R C

O IL

(O N

SO M

E M

O DE

LS )

TH (4

)

C

C

1

TO U

N IT

M U

ST B

E

VA C

G

C

TR (1

1)

G R

HO T

SU RF

AC E

IG N

IT ER

FL AM

E SE

NS O

R

PS 2

(1 2)

LO W

F IR

E PR

ES SU

R E

SW IT

CH 1

INTEGRATED CONTROL MODULE

L

BR

3

W IR

IN G

T O

U N

IT

N O

N EU

TR AL

N

WH

40 V

A TR

AN SF

O RM

ER

ID BL

W R

TO M IC

R O

W AR

N IN

G :D

IS C

O NN

EC T

BL

AU TO

R ES

ET AU

XI LI

AR Y

LI M

IT CO

NT R

O L

(T W

O O

N SO

M E

M O

DE LS

)

FU SE

3 A

2

24 V

3 A

BL

12

2

4

5 CIRCUIT CONNECTOR

4 CIRCUIT MOTOR CONNECTOR

4

1

FU SE

15 6 5LI N

E

2

RD

2

9

14

3

1

BR

11

EAC

CONTROL MODULE

8

WH

BL

BL

13

3

5

BR

7

1

3

FS

4

YL

OR

DI AG

NO ST

IC LE

D' S

PK

10

GR

RD

BL

BK

EA C

BR

O R

RO LL

O UT

S W

IT CH

IN (6

)

AU X

IN (3

)

PU

W H

W H

BK

NEUTRAL

TH ER

M O

ST AT

C R

1 2

D E

Y G

Manualsnet FAQs

If you want to find out how the GCVC80 Goodman works, you can view and download the Goodman GCVC80 User's Manual on the Manualsnet website.

Yes, we have the User's Manual for Goodman GCVC80 as well as other Goodman manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Manual should include all the details that are needed to use a Goodman GCVC80. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Goodman GCVC80 User's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Goodman GCVC80 User's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Goodman GCVC80 User's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Goodman GCVC80 User's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Goodman GCVC80 User's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.