Goodman GCEC80 User's Manual PDF

1 of 24
1 of 24

Summary of Content for Goodman GCEC80 User's Manual PDF

SS-GMEC80/GCEC80 www.goodmanmfg.com 12/21 Supersedes 2/21

Two-Stage, Multi-Speed ECM Gas Furnace

80% AFUE

GMEC80 / GCEC80 Heating Input: 40,000120,000 BTU/h

Contents Nomenclature ........................................ 2 Product Specifications ........................... 3 Dimensions ............................................ 5 Accessories ............................................ 6 Airflow Data ........................................... 7 Wiring Diagram ................................... 24

Standard Features Two-stage gas valve provides quiet,

economical heating Efficient and quiet multi-speed ECM circulator motor SureStart Silicon Nitride igniter

designed for long igniter life Self-diagnostic control board Low constant fan speed circulates air

throughout the home Quiet, two-speed induced draft blower California Low NOx emissions-compliant

models available Can no longer be installed in Californias

South Coast Air Quality Management District (SCAQMD) on or after October 1, 2019.

AHRI Certified; ETL Listed

Cabinet Features Fully insulated, heavy-gauge steel cabinet

with durable baked-enamel finish Multi-position installation:

GMEC80: upflow, horizontal left or right GCEC80: downflow, horizontal left or right

Removable bottom for side- or bottom-return applications

Convenient left or right connection for gas/electric service

Cabinet air leakage 2% Coil and furnace fit flush

for most installations

* Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Qubec.

2 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 3

Nomenclature

G M E C 80 040 4 C * **

1 2 3 4 5,6 7,8,9 10 11 12 13,14

Brand Engineering

G - Goodman Brand Major /Minor Revisions * Not used for inventory control.

Configuration NOx

M - Upflow/Horizontal N - Natural Gas

C - Downflow/Horizontal X - Low NOx

Motor Cabinet Width

V - Variable Speed ECM / ComfortBridge A - 14" C - 21"

E - Multi-Speed ECM S - Single Speed B - 17" D - 24"

Gas Valve Maximum CFM

M - Modulating S - Single Stage 2 - 800 CFM 4 - 1600 CFM

C - Two Stage 3 - 1200 CFM 5 - 2000 CFM

AFUE MBTU/h

80 - 80% AFUE 040 - 40,000 BTU/h 100 - 100,000 BTU/h

060 - 60,000 BTU/h 120 - 120,000 BTU/h

080 - 80,000 BTU/h

2 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 3

Specifications

GMEC80 0403A*

GMEC80 0603A*

GMEC80 0603B*

GMEC80 0803B*

GMEC80 0804B*

GMEC80 0804C*

GMEC80 0805C*

GMEC80 0805D*

GMEC80 1004C*

GMEC80 1005C*

GMEC80 1205D*

Heating Capacity

High Fire Input (BTU/h) 40,000 60,000 60,000 80,000 80,000 80,000 80,000 80,000 100,000 100,000 120,000

High Fire Output (BTU/h) :

Natural Gas 32,000 48,000 48,000 64,000 64,000 64,000 64,000 64,000 80,000 80,000 96,000

LP Gas 32,000 48,000 48,000 64,000 64,000 64,000 64,000 64,000 80,000 80,000 96,000

Low Fire Input (BTU/h) 28,000 42,000 42,000 56,000 56,000 56,000 56,000 56,000 70,000 70,000 84,000

Low Fire Output (BTU/h) :

Natural Gas 22,400 33,600 33,600 44,800 44,800 44,800 44,800 44,800 56,000 56,000 67,200

LP Gas 22,400 33,600 33,600 44,800 44,800 44,800 44,800 44,800 56,000 56,000 67,200

AFUE 80 80 80 80 80 80 80 80 80 80 80

Available AC @ 0.5 ESP 1.5 - 3.0 1.5 - 4.0 1.5 - 4.0 3.0 - 4.0 2.0 - 5.0 2.5 - 5.0 2.5 - 5.0 2.5 - 5.0 2.0 - 5.0 2.0 - 5.0 2.0 - 5.0

Temperature Rise Range ( F) 15-45/ 15-45

20-50/ 20-50

15-45/ 15-45

30-60/ 30-60

30-60/ 30-60

25-55/ 25-55

25-55/ 25-55

20-50/ 20-50

25-55/ 25-55

20-50/ 20-50

40-70/ 40-70

Circulator Blower

Size (D x W) 10 x 6 10 x 6 10 x 8 10" x 8" 10 x 10 10" x 10" 10" x 10" 11" x 10" 10 x 10 10 x 10 11 x 10

Horsepower - RPM 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 1 1

Speed 5 5 5 5 5 5 5 5 5 5 5

Vent Diameter 4 4 4 4 4 4 4 4 4 4 4

No. of Burners 3 3 3 4 4 4 4 4 5 5 6

Electrical Data Min. Circuit Ampacity 8.7 8.7 8.7 8.7 12.45 12.45 15.32 15.32 12.45 15.32 15.32

Max. Overcurrent Device (amps)4 15 15 15 15 15 15 20 20 15 20 20

Ship Weight (lbs) 105 107 107 118 121 129 129 129 124 124 124

Natural Gas BTU/h; for altitudes 0-4500 above sea level, reduce input rating by 4% for each 1000 above 4500 altitude. DOE AFUE based upon Isolated Combustion System (ICS) Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire

runs will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all

existing local codes.

4 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 5

Specifications

GCEC80 0403A*

GCEC80 0603A*

GCEC80 0603B*

GCEC80 0804B*

GCEC80 0805C*

GCEC80 1005C*

Heating Capacity

High Fire Input (BTU/h) 40,000 60,000 60,000 80,000 80,000 100,000

High Fire Output (BTU/h)

Natural Gas 32,000 48,000 48,000 64,000 64,000 80,000

LP Gas 32,000 48,000 48,000 64,000 64,000 80,000

Low Fire Input (BTU/h) 28,000 42,000 42,000 56,000 56,000 70,000

Low Fire Output (BTU/h)

Natural Gas 22,400 33,600 33,600 44,800 44,800 56,000

LP Gas 22,400 33,600 33,600 44,800 44,800 56,000

AFUE 80 80 80 80 80 80

Available AC @ 0.5 ESP 1.5 - 3.0 1.5 - 4.0 1.5 - 4.0 2.0 - 5.0 2.5 - 5.0 2.0 - 5.0

Temperature Rise Range ( F) 15-45 / 15-45 30-60 / 30-60 25-55 / 25-55 30-60 / 30-60 30-60 / 30-60 20-50 / 20-50

Circulator Blower

Size (D x W) 10 x 6 10 x 6 10 x 8 10 x 10 10" x 10" 10 x 10

Horsepower - RPM 1/2 1/2 1/2 3/4 3/4 1

Speed 5 5 5 5 5 5

Vent Diameter 4 4 4 4 4 4

No. of Burners 3 3 3 4 4 5

Electrical Data

Min. Circuit Ampacity 8.7 8.7 8.7 12.45 15.32 15.32

Max. Overcurrent Device (amps) 15 15 15 15 20 20

Ship Weight (lbs) 105 107 107 121 129 124 Natural Gas BTU/h; for altitudes 0-4500 above sea level, reduce input rating by 4% for each 1000 above 4500 altitude. DOE AFUE based upon Isolated Combustion System (ICS) Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes.

Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit

breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.

4 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 5

Minimum Clearances to Combustible Materials

Sides Rear Front Bottom Vent

Top SW B

1 0 3 C 6 1 1

C = If placed on combustible floor, the floor MUST be wood ONLY.

Notes: For servicing or cleaning, a 24 front clearance is recommended. Unit connections (electrical, flue, and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. Refer to the appropriate USA and Canadian codes:

In the USA: the National Fuel Gas Code NFPA 54 / ANSI Z223.1 In Canada: the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2

GMEC80 Dimensions

28

A B

1

33

23516

1716

13

20

27 Alt. Gas Inlet

Alt. High Voltage

Alt. Low Voltage

Alternate Gas Inlet

High-Voltage Inlet

Low-Voltage Inlet

Alt. Flue Outlet Horizontal Left

19

23

15

Model Dimensions

A B

GMEC800403A* 14" 12

GMEC800603A* 14" 12

GMEC800603B* 17 16"

GMEC800803B* 17 16"

GMEC800804B* 17 16"

GMEC800804C* 21" 19

GMEC800805C* 21" 19

GMEC800805D* 24 23"

GMEC801004C* 21" 19

GMEC801005C* 21" 19

GMEC801205D* 24 23"

6 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 7

GCEC80 Dimensions

A

B

High-Voltage Electrical

Low-Voltage Electrical

Gas Inlet

11

18

19

33

28

Minimum Clearances to Combustible Materials

Sides Rear Front Vent

Top SW B

1 0 3 6 1 1

Approved for line contact in the horizontal position. 24 clearance for serviceability recommended. Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables outlined in the

Installation Manual for additional venting requirements.

Model Dimensions

A B

GCEC800403A* 14" 12

GCEC800603A* 14" 12

GCEC800603B* 17 16"

GCEC800804B* 17 16"

GCEC800805C* 21" 19

GCEC801005C* 21" 19

Model Description GMEC80 0403A*

GMEC80 0603B*

GMEC80 0803B*

GMEC80 0804B*

GMEC80 0804C*

GMEC80 0805C*

GMEC80 0805D*

GMEC80 1005C*

AFE18-60A Fossil Fuel (Dual Fuel) Kit HA-02 High-Altitude Natural Gas Kit LPLP03 Low LP Gas Pressure Switch LPM-06 LP Conversion Kits

Model Description GCEC80 0403A*

GCEC80 0603A*

GCEC80 0603B*

GCEC80 0804B*

GCEC80 0805C*

GCEC80 1005C*

SBT14 Downflow Sub-Base 14" SBT17 Downflow Sub-Base 17.5" SBT21 Downflow Sub-Base 21" AFE18-60A Fossil Fuel (Dual Fuel) Kit HA-02 High-Altitude Natural Gas Kit LPLP03 Low LP Gas Pressure Switch LPM-06 LP Conversion Kits

Accessories

6 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 7

GCEC800403A* Airflow Data

PCBBF139 *CEC800403A* - COOLING

DIP SWITCHES S1-1, S1-2, S1-3

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF* Ylo 785 754 736 690 650 604 565 527

Y 1348 1294 1261 1250 1229 1233 1205 1182

ON OFF OFF Ylo 663 647 597 551 501 458 408 355

Y 785 754 736 690 650 604 565 527

ON ON OFF Ylo 663 647 597 551 501 458 408 355

Y 1348 1294 1261 1250 1229 1233 1205 1182

OFF ON OFF Ylo 785 754 736 690 650 604 565 527

Y 591 568 518 463 411 355 300 243

OFF OFF ON Ylo 785 754 736 690 650 604 565 527

Y 1104 1058 1020 1022 1013 981 952 918

OFF ON ON Ylo 663 647 597 551 501 458 408 355

Y 591 568 518 463 411 355 300 243

ON OFF ON Ylo 1104 1058 1020 1022 1013 981 952 918

Y 1348 1294 1261 1250 1229 1233 1205 1182

ON ON ON Ylo 1104 1058 1020 1022 1013 981 952 918

Y 663 647 597 551 501 458 408 355

PCBBF139 *CEC800403A* - CONTINOUS FAN

DIP Switches S2-2 S2-3 S2-4

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF G 591 568 518 463 411 355 300 243

ON OFF OFF G 1104 1058 1020 1022 1013 981 952 918

ON ON OFF G 663 647 597 551 501 458 408 355

OFF ON OFF G 785 754 736 690 650 604 565 527

OFF OFF ON G 1348 1294 1261 1250 1229 1233 1205 1182

OFF ON ON G 591 568 518 463 411 355 300 243

ON OFF ON G 591 568 518 463 411 355 300 243

ON ON ON G 591 568 518 463 411 355 300 243

PCBBF139 *CEC800403A* - HEATING

DIP Switches S1-4 S2-1

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM

OFF OFF* W1 591 35 568 37 518 40 463 45 411 N/A 355 300 243 W2 1104 27 1058 28 1020 29 1022 29 1013 29 981 952 918

ON OFF W1 663 31 647 32 597 35 551 38 501 41 458 408 355 W2 1104 27 1058 28 1020 29 1022 29 1013 29 981 952 918

ON ON W1 663 31 647 32 597 35 551 38 501 41 458 408 355 W2 785 38 754 39 736 40 690 43 650 N/A 604 565 527

OFF ON W1 785 26 754 28 736 28 690 30 650 32 604 565 527 W2 1348 22 1294 23 1261 23 1250 24 1229 24 1233 1205 1182

*DEFAULT **NOT RECOMMENDED

8 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 9

GCEC800603A* Airflow Data (cont.)

PCBBF139 *CEC800603A*- COOLING

DIP SWITCHES S1-1, S1-2, S1-3

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF* Ylo 1160 1102 1055 1017 970 930 891 847

Y 1411 1356 1313 1272 1235 1198 1162 1127

ON OFF OFF Ylo 656 589 532 465 402 348 271 219

Y 1160 1102 1055 1017 970 930 891 847

ON ON OFF Ylo 656 589 532 465 402 348 271 219

Y 1411 1356 1313 1272 1235 1198 1162 1127

OFF ON OFF Ylo 1160 1102 1055 1017 970 930 891 847

Y 716 647 592 541 478 420 368 296

OFF OFF ON Ylo 1160 1102 1055 1017 970 930 891 847

Y 1054 1002 951 906 861 820 797 754

OFF ON ON Ylo 656 589 532 465 402 348 271 219

Y 716 647 592 541 478 420 368 296

ON OFF ON Ylo 1054 1002 951 906 861 820 797 754

Y 1411 1356 1313 1272 1235 1198 1162 1127

ON ON ON Ylo 1054 1002 951 906 861 820 797 754

Y 656 589 532 465 402 348 271 219

PCBBF139 *CEC800603A* - CONTINOUS FAN

DIP Switches S2-2 S2-3 S2-4

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF G 716 647 592 541 478 420 368 296

ON OFF OFF G 1054 1002 951 906 861 820 797 754

ON ON OFF G 656 589 532 465 402 348 271 219

OFF ON OFF G 1160 1102 1055 1017 970 930 891 847

OFF OFF ON G 1411 1356 1313 1272 1235 1198 1162 1127

OFF ON ON G 716 647 592 541 478 420 368 296

ON OFF ON G 716 647 592 541 478 420 368 296

ON ON ON G 716 647 592 541 478 420 368 296

PCBBF139 *CEC800603A* - HEATING

DIP Switches S1-4 S2-1

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM

OFF OFF* W1 716 43 647 48 592 53 541 58 478 N/A 420 368 296 W2 1054 42 1002 44 951 47 906 49 861 52 820 797 754

ON OFF W1 656 47 589 53 532 58 465 N/A 402 N/A 348 271 219 W2 1054 42 1002 44 951 47 906 49 861 52 820 797 754

ON ON W1 656 47 589 53 532 58 465 N/A 402 N/A 348 271 219 W2 1160 38 1102 40 1055 42 1017 44 970 46 930 891 847

OFF ON** W1 1160 N/A 1102 N/A 1055 N/A 1017 N/A 970 N/A 930 891 847 W2 1411 N/A 1356 N/A 1313 N/A 1272 N/A 1235 N/A 1198 1162 1127

*DEFAULT **NOT RECOMMENDED

8 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 9

GCEC800603B* Airflow Data (cont.)

PCBBF139 *CEC800603B* - COOLING

DIP SWITCHES S1-1, S1-2, S1-3

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF* Ylo 1223 1144 1081 995 918 839 798 738

Y 1395 1332 1272 1207 1136 1074 1007 948

ON OFF OFF Ylo 1032 800 578 487 387 301 235 151

Y 1223 1144 1081 995 918 839 798 738

ON ON OFF Ylo 1032 800 578 487 387 301 235 151

Y 1395 1332 1272 1207 1136 1074 1007 948

OFF ON OFF Ylo 1223 1144 1081 995 918 839 798 738

Y 1025 850 754 670 594 520 443 366

OFF OFF ON Ylo 1223 1144 1081 995 918 839 798 738

Y 1258 1179 1115 1030 954 885 814 776

OFF ON ON Ylo 1032 800 578 487 387 301 235 151

Y 1025 850 754 670 594 520 443 366

ON OFF ON Ylo 1258 1179 1115 1030 954 885 814 776

Y 1395 1332 1272 1207 1136 1074 1007 948

ON ON ON Ylo 1258 1179 1115 1030 954 885 814 776

Y 1032 800 578 487 387 301 235 151

PCBBF139 *CEC800603B* - CONTINOUS FAN

DIP Switches S2-2 S2-3 S2-4

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF G 1025 850 754 670 594 520 443 366

ON OFF OFF G 1258 1179 1115 1030 954 885 814 776

ON ON OFF G 1032 800 578 487 387 301 235 151

OFF ON OFF G 1223 1144 1081 995 918 839 798 738

OFF OFF ON G 1395 1332 1272 1207 1136 1074 1007 948

OFF ON ON G 1025 850 754 670 594 520 443 366

ON OFF ON G 1025 850 754 670 594 520 443 366

ON ON ON G 1025 850 754 670 594 520 443 366

PCBBF139 *CEC800603B* - HEATING

DIP Switches S1-4 S2-1

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM

OFF OFF* W1 1025 30 850 37 754 41 670 46 594 52 520 443 366 W2 1258 35 1179 38 1115 40 1030 43 954 47 885 814 776

ON OFF W1 1032 30 800 39 578 54 487 N/A 387 N/A 301 235 151 W2 1258 35 1179 38 1115 40 1030 43 954 47 885 814 776

ON ON W1 1032 30 800 39 578 54 487 N/A 387 N/A 301 235 151 W2 1223 36 1144 39 1081 41 995 45 918 48 839 798 738

OFF ON** W1 1223 N/A 1144 N/A 1081 N/A 995 N/A 918 N/A 839 798 738 W2 1395 N/A 1332 N/A 1272 N/A 1207 N/A 1136 N/A 1074 1007 948

*DEFAULT **NOT RECOMMENDED

10 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 11

GCEC800804B* Airflow Data (cont.)

PCBBF139 *CEC800804B* - COOLING

DIP SWITCHES S1-1, S1-2, S1-3

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF* Ylo 1596 1553 1512 1491 1450 1411 1388 1347

Y 1757 1713 1691 1664 1625 1588 1552 1522

ON OFF OFF Ylo 784 716 645 583 516 405 334 282

Y 1596 1553 1512 1491 1450 1411 1388 1347

ON ON OFF Ylo 784 716 645 583 516 405 334 282

Y 1757 1713 1691 1664 1625 1588 1552 1522

OFF ON OFF Ylo 1596 1553 1512 1491 1450 1411 1388 1347

Y 1040 973 936 918 859 805 770 720

OFF OFF ON Ylo 1596 1553 1512 1491 1450 1411 1388 1347

Y 1401 1366 1320 1278 1236 1194 1153 1112

OFF ON ON Ylo 784 716 645 583 516 405 334 282

Y 1040 973 936 918 859 805 770 720

ON OFF ON Ylo 1401 1366 1320 1278 1236 1194 1153 1112

Y 1757 1713 1691 1664 1625 1588 1552 1522

ON ON ON Ylo 1401 1366 1320 1278 1236 1194 1153 1112

Y 784 716 645 583 516 405 334 282

PCBBF139 *CEC800804B* - CONTINOUS FAN

DIP Switches S2-2 S2-3 S2-4

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF G 1040 973 936 918 859 805 770 720

ON OFF OFF G 1401 1366 1320 1278 1236 1194 1153 1112

ON ON OFF G 784 716 645 583 516 405 334 282

OFF ON OFF G 1596 1553 1512 1491 1450 1411 1388 1347

OFF OFF ON G 1757 1713 1691 1664 1625 1588 1552 1522

OFF ON ON G 1040 973 936 918 859 805 770 720

ON OFF ON G 1040 973 936 918 859 805 770 720

ON ON ON G 1040 973 936 918 859 805 770 720

PCBBF139 *CEC800804B* - HEATING

DIP Switches S1-4 S2-1

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM

OFF OFF* W1 1040 40 973 43 936 44 918 45 859 48 805 770 720 W2 1401 42 1366 43 1320 45 1278 46 1236 48 1194 1153 1112

ON OFF W1 784 53 716 58 645 N/A 583 N/A 516 N/A 405 334 282 W2 1401 42 1366 43 1320 45 1278 46 1236 48 1194 1153 1112

ON ON W1 784 53 716 58 645 N/A 583 N/A 516 N/A 405 334 282 W2 1596 37 1553 38 1512 39 1491 40 1450 41 1411 1388 1347

OFF ON** W1 1596 N/A 1553 N/A 1512 N/A 1491 N/A 1450 N/A 1411 1388 1347 W2 1757 N/A 1713 N/A 1691 N/A 1664 N/A 1625 N/A 1588 1552 1522

*DEFAULT **NOT RECOMMENDED

10 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 11

*CEC800805C* Airflow Data (cont.)

PCBBF139 *CEC800805C* - COOLING

DIP SWITCHES S1-1, S1-2, S1-3

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF* Ylo 1782 1744 1715 1700 1660 1619 1579 1510

Y 2145 2089 2058 2036 2020 2000 1971 1935

ON OFF OFF Ylo 1171 884 667 576 495 399 338 302

Y 1782 1744 1715 1700 1660 1619 1579 1510

ON ON OFF Ylo 1171 884 667 576 495 399 338 302

Y 2145 2089 2058 2036 2020 2000 1971 1935

OFF ON OFF Ylo 1782 1744 1715 1700 1660 1619 1579 1510

Y 1175 1098 1024 947 883 823 764 703

OFF OFF ON Ylo 1782 1744 1715 1700 1660 1619 1579 1510

Y 1547 1506 1474 1442 1390 1332 1273 1222

OFF ON ON Ylo 1171 884 667 576 495 399 338 302

Y 1175 1098 1024 947 883 823 764 703

ON OFF ON Ylo 1547 1506 1474 1442 1390 1332 1273 1222

Y 2145 2089 2058 2036 2020 2000 1971 1935

ON ON ON Ylo 1547 1506 1474 1442 1390 1332 1273 1222

Y 1171 884 667 576 495 399 338 302

PCBBF139 *CEC800805C* - CONTINOUS FAN

DIP Switches S2-2 S2-3 S2-4

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF G 1175 1098 1024 947 883 823 764 703

ON OFF OFF G 1547 1506 1474 1442 1390 1332 1273 1222

ON ON OFF G 1171 884 667 576 495 399 338 302

OFF ON OFF G 1782 1744 1715 1700 1660 1619 1579 1510

OFF OFF ON G 2145 2089 2058 2036 2020 2000 1971 1935

OFF ON ON G 1175 1098 1024 947 883 823 764 703

ON OFF ON G 1175 1098 1024 947 883 823 764 703

ON ON ON G 1175 1098 1024 947 883 823 764 703

PCBBF139 *CEC800805C* - HEATING

DIP Switches S1-4 S2-1

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM

OFF OFF* W1 1175 35 1098 38 1024 41 947 44 883 47 823 764 703 W2 1547 38 1506 39 1474 40 1442 41 1390 43 1332 1273 1222

ON OFF W1 1171 35 884 47 667 N/A 576 N/A 495 N/A 399 338 302 W2 1547 38 1506 39 1474 40 1442 41 1390 43 1332 1273 1222

ON ON** W1 1171 N/A 884 N/A 667 N/A 576 N/A 495 N/A 399 338 302 W2 1782 N/A 1744 N/A 1715 N/A 1700 N/A 1660 N/A 1619 1579 1510

OFF ON** W1 1782 N/A 1744 N/A 1715 N/A 1700 N/A 1660 N/A 1619 1579 1510 W2 2145 N/A 2089 N/A 2058 N/A 2036 N/A 2020 N/A 2000 1971 1935

*DEFAULT **NOT RECOMMENDED

12 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 13

PCBBF139 **EC801005C* - COOLING

DIP SWITCHES S1-1, S1-2, S1-3

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF* Ylo 1820 1769 1726 1685 1642 1603 1557 1521

Y 2235 2185 2139 2108 2076 2032 2000 1964

ON OFF OFF Ylo 803 719 631 540 471 337 298 265

Y 1820 1769 1726 1685 1642 1603 1557 1521

ON ON OFF Ylo 803 719 631 540 471 337 298 265

Y 2235 2185 2139 2108 2076 2032 2000 1964

OFF ON OFF Ylo 1820 1769 1726 1685 1642 1603 1557 1521

Y 1626 1574 1524 1479 1433 1410 1400 1358

OFF OFF ON Ylo 1820 1769 1726 1685 1642 1603 1557 1521

Y 2169 2116 2070 2038 2003 1970 1933 1897

OFF ON ON Ylo 803 719 631 540 471 337 298 265

Y 1626 1574 1524 1479 1433 1410 1400 1358

ON OFF ON Ylo 2169 2116 2070 2038 2003 1970 1933 1897

Y 2235 2185 2139 2108 2076 2032 2000 1964

ON ON ON Ylo 2169 2116 2070 2038 2003 1970 1933 1897

Y 803 719 631 540 471 337 298 265

PCBBF139 **EC801005C* - CONTINOUS FAN

DIP Switches S2-2 S2-3 S2-4

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF G 1626 1574 1524 1479 1433 1410 1400 1358

ON OFF OFF G 2169 2116 2070 2038 2003 1970 1933 1897

ON ON OFF G 803 719 631 540 471 337 298 265

OFF ON OFF G 1820 1769 1726 1685 1642 1603 1557 1521

OFF OFF ON G 2235 2185 2139 2108 2076 2032 2000 1964

OFF ON ON G 1626 1574 1524 1479 1433 1410 1400 1358

ON OFF ON G 1626 1574 1524 1479 1433 1410 1400 1358

ON ON ON G 1626 1574 1524 1479 1433 1410 1400 1358

PCBBF139 **EC801005C* - HEATING

DIP Switches S1-4 S2-1

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM

OFF OFF* W1 1626 32 1574 33 1524 34 1479 35 1433 36 1410 1400 1358 W2 2169 34 2116 35 2070 36 2038 36 2003 37 1970 1933 1897

ON OFF W1 803 N/A 719 N/A 631 N/A 540 N/A 471 N/A 337 298 265 W2 2169 34 2116 35 2070 36 2038 36 2003 37 1970 1933 1897

ON ON W1 803 N/A 719 N/A 631 N/A 540 N/A 471 N/A 337 298 265 W2 1820 41 1769 42 1726 43 1685 44 1642 45 1603 1557 1521

OFF ON** W1 1820 N/A 1769 N/A 1726 N/A 1685 N/A 1642 N/A 1603 1557 1521 W2 2235 N/A 2185 N/A 2139 N/A 2108 N/A 2076 N/A 2032 2000 1964

*DEFAULT **NOT RECOMMENDED

**EC801005C* Airflow Data (cont.)

12 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 13

PCBBF139 *MEC800403A* - COOLING

DIP SWITCHES S1-1, S1-2, S1-3

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF* Ylo 1138 1093 1057 1016 981 945 912 876

Y 1367 1321 1286 1255 1223 1190 1160 1133

ON OFF OFF Ylo 923 865 824 802 759 715 674 631

Y 1138 1093 1057 1016 981 945 912 876

ON ON OFF Ylo 923 865 824 802 759 715 674 631

Y 1367 1321 1286 1255 1223 1190 1160 1133

OFF ON OFF Ylo 1138 1093 1057 1016 981 945 912 876

Y 553 496 436 372 308 252 198 N/A

OFF OFF ON Ylo 1138 1093 1057 1016 981 945 912 876

Y 750 703 651 600 553 504 456 409

OFF ON ON Ylo 923 865 824 802 759 715 674 631

Y 553 496 436 372 308 252 198 N/A

ON OFF ON Ylo 750 703 651 600 553 504 456 409

Y 1367 1321 1286 1255 1223 1190 1160 1133

ON ON ON Ylo 750 703 651 600 553 504 456 409

Y 923 865 824 802 759 715 674 631

PCBBF139 *MEC800403A* - CONTINOUS FAN

DIP Switches S2-2 S2-3 S2-4

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF G 553 496 436 372 308 252 198 N/A

ON OFF OFF G 750 703 651 600 553 504 456 409

ON ON OFF G 923 865 824 802 759 715 674 631

OFF ON OFF G 1138 1093 1057 1016 981 945 912 876

OFF OFF ON G 1367 1321 1286 1255 1223 1190 1160 1133

OFF ON ON G 553 496 436 372 308 252 198 N/A

ON OFF ON G 553 496 436 372 308 252 198 N/A

ON ON ON G 553 496 436 372 308 252 198 N/A

PCBBF139 *MEC800403A* - HEATING

DIP Switches S1-4 S2-1

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM

OFF OFF* W1 553 38 496 42 436 N/A 372 N/A 308 N/A 252 198 N/A W2 750 40 703 42 651 N/A 600 N/A 553 N/A 504 456 409

ON OFF W1 923 22 865 24 824 25 802 26 759 27 715 674 631 W2 750 40 703 42 651 N/A 600 N/A 553 N/A 504 456 409

ON ON W1 923 22 865 24 824 25 802 26 759 27 715 674 631 W2 1138 26 1093 27 1057 28 1016 29 981 30 945 912 876

OFF ON** W1 1138 N/A 1093 N/A 1057 N/A 1016 N/A 981 N/A 945 912 876 W2 1367 N/A 1321 N/A 1286 N/A 1255 N/A 1223 N/A 1190 1160 1133

GMEC800403A* Airflow Data (cont.)

*DEFAULT **NOT RECOMMENDED

14 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 15

GMEC800603A* Airflow Data (cont.)

PCBBF139 *MEC800603A* - COOLING

DIP SWITCHES S1-1, S1-2, S1-3

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF* Ylo 1151 1091 1050 1007 964 926 885 850

Y 1389 1341 1295 1258 1221 1176 1140 1105

ON OFF OFF Ylo 681 617 566 511 458 405 358 311

Y 1151 1091 1050 1007 964 926 885 850

ON ON OFF Ylo 681 617 566 511 458 405 358 311

Y 1389 1341 1295 1258 1221 1176 1140 1105

OFF ON OFF Ylo 1151 1091 1050 1007 964 926 885 850

Y 1079 1019 975 934 890 850 808 791

OFF OFF ON Ylo 1151 1091 1050 1007 964 926 885 850

Y 1328 1274 1231 1191 1155 1114 1081 1047

OFF ON ON Ylo 681 617 566 511 458 405 358 311

Y 1079 1019 975 934 890 850 808 791

ON OFF ON Ylo 1328 1274 1231 1191 1155 1114 1081 1047

Y 1389 1341 1295 1258 1221 1176 1140 1105

ON ON ON Ylo 1328 1274 1231 1191 1155 1114 1081 1047

Y 681 617 566 511 458 405 358 311

PCBBF139 *MEC800603A* - CONTINOUS FAN

DIP Switches S2-2 S2-3 S2-4

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF G 1079 1019 975 934 890 850 808 791

ON OFF OFF G 1328 1274 1231 1191 1155 1114 1081 1047

ON ON OFF G 681 617 566 511 458 405 358 311

OFF ON OFF G 1151 1091 1050 1007 964 926 885 850

OFF OFF ON G 1389 1341 1295 1258 1221 1176 1140 1105

OFF ON ON G 1079 1019 975 934 890 850 808 791

ON OFF ON G 1079 1019 975 934 890 850 808 791

ON ON ON G 1079 1019 975 934 890 850 808 791

PCBBF139 *MEC800603A* - HEATING

DIP Switches S1-4 S2-1

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM

OFF OFF* W1 1079 29 1019 31 975 32 934 33 890 35 850 808 791 W2 1328 33 1274 35 1231 36 1191 37 1155 38 1114 1081 1047

ON OFF W1 681 46 617 50 566 N/A 511 N/A 458 N/A 405 358 311 W2 1328 33 1274 35 1231 36 1191 37 1155 38 1114 1081 1047

ON ON W1 681 46 617 50 566 N/A 511 N/A 458 N/A 405 358 311 W2 1151 39 1091 41 1050 42 1007 44 964 46 926 885 850

OFF ON W1 1151 27 1091 29 1050 30 1007 31 964 32 926 885 850 W2 1389 32 1341 33 1295 34 1258 35 1221 36 1176 1140 1105

*DEFAULT **NOT RECOMMENDED

14 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 15

GMEC800603B* Airflow Data (cont.)

PCBBF139 *MEC800603B* - COOLING

DIP SWITCHES S1-1, S1-2, S1-3

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF* Ylo 1330 1280 1229 1187 1146 1103 1061 1018

Y 1465 1416 1382 1340 1299 1278 1257 1219

ON OFF OFF Ylo 737 661 589 531 456 384 313 252

Y 1330 1280 1229 1187 1146 1103 1061 1018

ON ON OFF Ylo 737 661 589 531 456 384 313 252

Y 1465 1416 1382 1340 1299 1278 1257 1219

OFF ON OFF Ylo 1330 1280 1229 1187 1146 1103 1061 1018

Y 1155 1100 1048 1002 952 907 861 816

OFF OFF ON Ylo 1330 1280 1229 1187 1146 1103 1061 1018

Y 1418 1376 1333 1288 1248 1206 1163 1124

OFF ON ON Ylo 737 661 589 531 456 384 313 252

Y 1155 1100 1048 1002 952 907 861 816

ON OFF ON Ylo 1418 1376 1333 1288 1248 1206 1163 1124

Y 1465 1416 1382 1340 1299 1278 1257 1219

ON ON ON Ylo 1418 1376 1333 1288 1248 1206 1163 1124

Y 737 661 589 531 456 384 313 252

PCBBF139 *MEC800603B* - CONTINOUS FAN

DIP Switches S2-2 S2-3 S2-4

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF G 1155 1100 1048 1002 952 907 861 816

ON OFF OFF G 1418 1376 1333 1288 1248 1206 1163 1124

ON ON OFF G 737 661 589 531 456 384 313 252

OFF ON OFF G 1330 1280 1229 1187 1146 1103 1061 1018

OFF OFF ON G 1465 1416 1382 1340 1299 1278 1257 1219

OFF ON ON G 1155 1100 1048 1002 952 907 861 816

ON OFF ON G 1155 1100 1048 1002 952 907 861 816

ON ON ON G 1155 1100 1048 1002 952 907 861 816

PCBBF139 *MEC800603B* - HEATING

DIP Switches S1-4 S2-1

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM

OFF OFF* W1 1155 27 1100 28 1048 30 1002 31 952 33 907 861 816 W2 1418 31 1376 32 1333 33 1288 35 1248 36 1206 1163 1124

ON OFF W1 737 42 661 N/A 589 N/A 531 N/A 456 N/A 384 313 252 W2 1418 31 1376 32 1333 33 1288 35 1248 36 1206 1163 1124

ON ON W1 737 42 661 N/A 589 N/A 531 N/A 456 N/A 384 313 252 W2 1330 33 1280 35 1229 36 1187 37 1146 39 1103 1061 1018

OFF ON** W1 1330 N/A 1280 N/A 1229 N/A 1187 N/A 1146 N/A 1103 1061 1018 W2 1465 N/A 1416 N/A 1382 N/A 1340 N/A 1299 N/A 1278 1257 1219

*DEFAULT **NOT RECOMMENDED

16 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 17

PCBBF139 *MEC800803B* - COOLING

DIP SWITCHES S1-1, S1-2, S1-3

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF* Ylo 1160 1107 1060 1011 965 920 868 818

Y 1231 1185 1136 1093 1049 1004 956 908

ON OFF OFF Ylo 706 631 563 486 404 338 280 232

Y 1160 1107 1060 1011 965 920 868 818

ON ON OFF Ylo 706 631 563 486 404 338 280 232

Y 1231 1185 1136 1093 1049 1004 956 908

OFF ON OFF Ylo 1160 1107 1060 1011 965 920 868 818

Y 1133 1009 956 903 856 804 774 722

OFF OFF ON Ylo 1160 1107 1060 1011 965 920 868 818

Y 1402 1358 1317 1274 1234 1195 1154 1113

OFF ON ON Ylo 706 631 563 486 404 338 280 232

Y 1133 1009 956 903 856 804 774 722

ON OFF ON Ylo 1402 1358 1317 1274 1234 1195 1154 1113

Y 1231 1185 1136 1093 1049 1004 956 908

ON ON ON Ylo 1402 1358 1317 1274 1234 1195 1154 1113

Y 706 631 563 486 404 338 280 232

PCBBF139 *MEC800803B* - CONTINOUS FAN

DIP Switches S2-2 S2-3 S2-4

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF G 1133 1009 956 903 856 804 774 722

ON OFF OFF G 1402 1358 1317 1274 1234 1195 1154 1113

ON ON OFF G 706 631 563 486 404 338 280 232

OFF ON OFF G 1160 1107 1060 1011 965 920 868 818

OFF OFF ON G 1231 1185 1136 1093 1049 1004 956 908

OFF ON ON G 1133 1009 956 903 856 804 774 722

ON OFF ON G 1133 1009 956 903 856 804 774 722

ON ON ON G 1133 1009 956 903 856 804 774 722

PCBBF139 *MEC800803B* - HEATING

DIP Switches S1-4 S2-1

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM

OFF OFF* W1 1133 37 1009 41 956 43 903 46 856 48 804 774 722 W2 1402 42 1358 44 1317 45 1274 47 1234 48 1195 1154 1113

ON OFF** W1 706 N/A 631 N/A 563 N/A 486 N/A 404 N/A 338 280 232 W2 1402 N/A 1358 N/A 1317 N/A 1274 N/A 1234 N/A 1195 1154 1113

ON ON** W1 706 N/A 631 N/A 563 N/A 486 N/A 404 N/A 338 280 232 W2 1160 N/A 1107 N/A 1060 N/A 1011 N/A 965 N/A 920 868 818

OFF ON W1 1160 36 1107 37 1060 39 1011 41 965 43 920 868 818 W2 1231 48 1185 50 1136 52 1093 54 1049 56 1004 956 908

*DEFAULT **NOT RECOMMENDED

GMEC800803B* Airflow Data (cont.)

16 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 17

GMEC800804B* Airflow Data (cont.)

PCBBF139 *MEC800804B* - COOLING

DIP SWITCHES S1-1, S1-2, S1-3

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF* Ylo 1574 1521 1481 1439 1398 1374 1335 1295

Y 1782 1726 1684 1645 1610 1574 1542 1506

ON OFF OFF Ylo 743 668 599 522 432 366 312 258

Y 1574 1521 1481 1439 1398 1374 1335 1295

ON ON OFF Ylo 743 668 599 522 432 366 312 258

Y 1782 1726 1684 1645 1610 1574 1542 1506

OFF ON OFF Ylo 1574 1521 1481 1439 1398 1374 1335 1295

Y 1130 1071 1027 973 922 870 817 787

OFF OFF ON Ylo 1574 1521 1481 1439 1398 1374 1335 1295

Y 1408 1369 1319 1282 1242 1193 1150 1109

OFF ON ON Ylo 743 668 599 522 432 366 312 258

Y 1130 1071 1027 973 922 870 817 787

ON OFF ON Ylo 1408 1369 1319 1282 1242 1193 1150 1109

Y 1782 1726 1684 1645 1610 1574 1542 1506

ON ON ON Ylo 1408 1369 1319 1282 1242 1193 1150 1109

Y 743 668 599 522 432 366 312 258

PCBBF139 *MEC800804B* - CONTINOUS FAN

DIP Switches S2-2 S2-3 S2-4

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF G 1130 1071 1027 973 922 870 817 787

ON OFF OFF G 1408 1369 1319 1282 1242 1193 1150 1109

ON ON OFF G 743 668 599 522 432 366 312 258

OFF ON OFF G 1574 1521 1481 1439 1398 1374 1335 1295

OFF OFF ON G 1782 1726 1684 1645 1610 1574 1542 1506

OFF ON ON G 1130 1071 1027 973 922 870 817 787

ON OFF ON G 1130 1071 1027 973 922 870 817 787

ON ON ON G 1130 1071 1027 973 922 870 817 787

PCBBF139 *MEC800804B* - HEATING

DIP Switches S1-4 S2-1

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM

OFF OFF* W1 1130 37 1071 39 1027 40 973 43 922 45 870 817 787 W2 1408 42 1369 43 1319 45 1282 46 1242 48 1193 1150 1109

ON OFF W1 743 56 668 N/A 599 N/A 522 N/A 432 N/A 366 312 258 W2 1408 42 1369 43 1319 45 1282 46 1242 48 1193 1150 1109

ON ON** W1 743 N/A 668 N/A 599 N/A 522 N/A 432 N/A 366 312 258 W2 1574 N/A 1521 N/A 1481 N/A 1439 N/A 1398 N/A 1374 1335 1295

OFF ON W1 1574 26 1521 27 1481 28 1439 29 1398 30 1374 1335 1295 W2 1782 33 1726 34 1684 35 1645 36 1610 37 1574 1542 1506

*DEFAULT **NOT RECOMMENDED

18 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 19

PCBBF139 *MEC800804C* - COOLING

DIP SWITCHES S1-1, S1-2, S1-3

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF* Ylo 1466 1399 1347 1290 1230 1170 1112 1054

Y 1904 1832 1777 1727 1678 1630 1579 1523

ON OFF OFF Ylo 822 754 652 566 499 428 346 294

Y 1466 1399 1347 1290 1230 1170 1112 1054

ON ON OFF Ylo 822 754 652 566 499 428 346 294

Y 1904 1832 1777 1727 1678 1630 1579 1523

OFF ON OFF Ylo 1466 1399 1347 1290 1230 1170 1112 1054

Y 1352 1281 1218 1152 1076 1026 964 901

OFF OFF ON Ylo 1466 1399 1347 1290 1230 1170 1112 1054

Y 1669 1595 1527 1463 1407 1363 1336 1289

OFF ON ON Ylo 822 754 652 566 499 428 346 294

Y 1352 1281 1218 1152 1076 1026 964 901

ON OFF ON Ylo 1669 1595 1527 1463 1407 1363 1336 1289

Y 1904 1832 1777 1727 1678 1630 1579 1523

ON ON ON Ylo 1669 1595 1527 1463 1407 1363 1336 1289

Y 822 754 652 566 499 428 346 294

PCBBF139 *MEC800804C* - CONTINOUS FAN

DIP Switches S2-2 S2-3 S2-4

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF G 1352 1281 1218 1152 1076 1026 964 901

ON OFF OFF G 1669 1595 1527 1463 1407 1363 1336 1289

ON ON OFF G 822 754 652 566 499 428 346 294

OFF ON OFF G 1466 1399 1347 1290 1230 1170 1112 1054

OFF OFF ON G 1904 1832 1777 1727 1678 1630 1579 1523

OFF ON ON G 1352 1281 1218 1152 1076 1026 964 901

ON OFF ON G 1352 1281 1218 1152 1076 1026 964 901

ON ON ON G 1352 1281 1218 1152 1076 1026 964 901

PCBBF139 *MEC800804C* - HEATING

DIP Switches S1-4 S2-1

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM

OFF OFF* W1 1352 31 1281 32 1218 34 1152 36 1076 39 1026 964 901 W2 1669 36 1595 37 1527 39 1463 41 1407 42 1363 1336 1289

ON OFF W1 822 50 754 55 652 N/A 566 N/A 499 N/A 428 346 294 W2 1669 36 1595 37 1527 39 1463 41 1407 42 1363 1336 1289

ON ON W1 822 50 754 55 652 N/A 566 N/A 499 N/A 428 346 294 W2 1466 40 1399 42 1347 44 1290 46 1230 48 1170 1112 1054

OFF ON W1 1466 28 1399 30 1347 31 1290 32 1230 34 1170 1112 1054 W2 1904 31 1832 32 1777 33 1727 34 1678 35 1630 1579 1523

*DEFAULT **NOT RECOMMENDED

GMEC800804C* Airflow Data (cont.)

18 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 19

GMEC800805D* Airflow Data (cont.)

PCBBF139 *MEC800805D* - COOLING

DIP SWITCHES S1-1, S1-2, S1-3

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF* Ylo 1698 1621 1553 1497 1437 1393 1328 1270

Y 2266 2202 2143 2090 2040 1995 1945 1896

ON OFF OFF Ylo 1088 999 899 772 667 561 490 418

Y 1698 1621 1553 1497 1437 1393 1328 1270

ON ON OFF Ylo 1088 999 899 772 667 561 490 418

Y 2266 2202 2143 2090 2040 1995 1945 1896

OFF ON OFF Ylo 1698 1621 1553 1497 1437 1393 1328 1270

Y 1450 1382 1314 1243 1181 1115 1047 973

OFF OFF ON Ylo 1698 1621 1553 1497 1437 1393 1328 1270

Y 1886 1822 1758 1701 1646 1591 1535 1482

OFF ON ON Ylo 1088 999 899 772 667 561 490 418

Y 1450 1382 1314 1243 1181 1115 1047 973

ON OFF ON Ylo 1886 1822 1758 1701 1646 1591 1535 1482

Y 2266 2202 2143 2090 2040 1995 1945 1896

ON ON ON Ylo 1886 1822 1758 1701 1646 1591 1535 1482

Y 1088 999 899 772 667 561 490 418

PCBBF139 *MEC800805D* - CONTINOUS FAN

DIP Switches S2-2 S2-3 S2-4

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF G 1450 1382 1314 1243 1181 1115 1047 973

ON OFF OFF G 1886 1822 1758 1701 1646 1591 1535 1482

ON ON OFF G 1088 999 899 772 667 561 490 418

OFF ON OFF G 1698 1621 1553 1497 1437 1393 1328 1270

OFF OFF ON G 2266 2202 2143 2090 2040 1995 1945 1896

OFF ON ON G 1450 1382 1314 1243 1181 1115 1047 973

ON OFF ON G 1450 1382 1314 1243 1181 1115 1047 973

ON ON ON G 1450 1382 1314 1243 1181 1115 1047 973

PCBBF139 *MEC800805D* - HEATING

DIP Switches S1-4 S2-1

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM

OFF OFF* W1 1450 29 1382 30 1314 32 1243 33 1181 35 1115 1047 973 W2 1886 31 1822 33 1758 34 1701 35 1646 36 1591 1535 1482

ON OFF W1 1088 38 999 42 899 46 772 N/A 667 N/A 561 490 418 W2 1886 31 1822 33 1758 34 1701 35 1646 36 1591 1535 1482

ON ON W1 1088 38 999 42 899 46 772 N/A 667 N/A 561 490 418 W2 1698 35 1621 37 1553 38 1497 40 1437 41 1393 1328 1270

OFF ON W1 1698 24 1621 26 1553 27 1497 28 1437 29 1393 1328 1270 W2 2266 26 2202 27 2143 28 2090 28 2040 29 1995 1945 1896

*DEFAULT **NOT RECOMMENDED

20 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 21

PCBBF139 *MEC800805C* - COOLING

DIP SWITCHES S1-1, S1-2, S1-3

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF* Ylo 1583 1536 1515 1478 1434 1383 1317 1265

Y 2145 2089 2058 2036 2020 2000 1971 1935

ON OFF OFF Ylo 1171 884 667 576 495 399 338 302

Y 1583 1536 1515 1478 1434 1383 1317 1265

ON ON OFF Ylo 1171 884 667 576 495 399 338 302

Y 2145 2089 2058 2036 2020 2000 1971 1935

OFF ON OFF Ylo 1583 1536 1515 1478 1434 1383 1317 1265

Y 1436 1402 1362 1313 1244 1182 1132 1079

OFF OFF ON Ylo 1583 1536 1515 1478 1434 1383 1317 1265

Y 1782 1744 1715 1700 1660 1619 1579 1510

OFF ON ON Ylo 1171 884 667 576 495 399 338 302

Y 1436 1402 1362 1313 1244 1182 1132 1079

ON OFF ON Ylo 1782 1744 1715 1700 1660 1619 1579 1510

Y 2145 2089 2058 2036 2020 2000 1971 1935

ON ON ON Ylo 1782 1744 1715 1700 1660 1619 1579 1510

Y 1171 884 667 576 495 399 338 302

PCBBF139 *MEC800805C* - CONTINOUS FAN

DIP Switches S2-2 S2-3 S2-4

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF G 1436 1402 1362 1313 1244 1182 1132 1079

ON OFF OFF G 1782 1744 1715 1700 1660 1619 1579 1510

ON ON OFF G 1171 884 667 576 495 399 338 302

OFF ON OFF G 1583 1536 1515 1478 1434 1383 1317 1265

OFF OFF ON G 2145 2089 2058 2036 2020 2000 1971 1935

OFF ON ON G 1436 1402 1362 1313 1244 1182 1132 1079

ON OFF ON G 1436 1402 1362 1313 1244 1182 1132 1079

ON ON ON G 1436 1402 1362 1313 1244 1182 1132 1079

PCBBF139 *MEC800805C* - HEATING

DIP Switches S1-4 S2-1

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM

OFF OFF* W1 1436 29 1402 30 1362 30 1313 32 1244 33 1182 1132 1079 W2 1782 33 1744 34 1715 35 1700 35 1660 36 1619 1579 1510

ON OFF W1 1171 35 884 47 667 N/A 576 N/A 495 N/A 399 338 302 W2 1782 33 1744 34 1715 35 1700 35 1660 36 1619 1579 1510

ON ON W1 1171 35 884 47 667 N/A 576 N/A 495 N/A 399 338 302 W2 1583 37 1536 39 1515 39 1478 40 1434 41 1383 1317 1265

OFF ON** W1 1583 N/A 1536 N/A 1515 N/A 1478 N/A 1434 N/A 1383 1317 1265 W2 2145 N/A 2089 N/A 2058 N/A 2036 N/A 2020 N/A 2000 1971 1935

*DEFAULT **NOT RECOMMENDED

GMEC800805C* Airflow Data (cont.)

20 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 21

GMEC801004C* Airflow Data (cont.)

PCBBF139 *MEC801004C* - COOLING

DIP SWITCHES S1-1, S1-2, S1-3

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF* Ylo 1265 1204 1146 1091 1034 973 918 870

Y 1598 1547 1509 1464 1417 1387 1340 1295

ON OFF OFF Ylo 789 719 637 545 458 378 324 273

Y 1265 1204 1146 1091 1034 973 918 870

ON ON OFF Ylo 789 719 637 545 458 378 324 273

Y 1598 1547 1509 1464 1417 1387 1340 1295

OFF ON OFF Ylo 1265 1204 1146 1091 1034 973 918 870

Y 1424 1378 1330 1274 1226 1172 1119 1071

OFF OFF ON Ylo 1265 1204 1146 1091 1034 973 918 870

Y 1810 1764 1718 1682 1633 1596 1549 1510

OFF ON ON Ylo 789 719 637 545 458 378 324 273

Y 1424 1378 1330 1274 1226 1172 1119 1071

ON OFF ON Ylo 1810 1764 1718 1682 1633 1596 1549 1510

Y 1598 1547 1509 1464 1417 1387 1340 1295

ON ON ON Ylo 1810 1764 1718 1682 1633 1596 1549 1510

Y 789 719 637 545 458 378 324 273

PCBBF139 *MEC801004C* - CONTINOUS FAN

DIP Switches S2-2 S2-3 S2-4

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF G 1424 1378 1330 1274 1226 1172 1119 1071

ON OFF OFF G 1810 1764 1718 1682 1633 1596 1549 1510

ON ON OFF G 789 719 637 545 458 378 324 273

OFF ON OFF G 1265 1204 1146 1091 1034 973 918 870

OFF OFF ON G 1598 1547 1509 1464 1417 1387 1340 1295

OFF ON ON G 1424 1378 1330 1274 1226 1172 1119 1071

ON OFF ON G 1424 1378 1330 1274 1226 1172 1119 1071

ON ON ON G 1424 1378 1330 1274 1226 1172 1119 1071

PCBBF139 *MEC801004C* - HEATING

DIP Switches S1-4 S2-1

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM

OFF OFF* W1 1424 36 1378 38 1330 39 1274 41 1226 42 1172 1119 1071 W2 1810 41 1764 42 1718 43 1682 44 1633 45 1596 1549 1510

ON OFF** W1 789 N/A 719 N/A 637 N/A 545 N/A 458 N/A 378 324 273 W2 1810 N/A 1764 N/A 1718 N/A 1682 N/A 1633 N/A 1596 1549 1510

ON ON** W1 789 N/A 719 N/A 637 N/A 545 N/A 458 N/A 378 324 273 W2 1265 N/A 1204 N/A 1146 N/A 1091 N/A 1034 N/A 973 918 870

OFF ON W1 1265 41 1204 43 1146 45 1091 48 1034 50 973 918 870 W2 1598 46 1547 48 1509 49 1464 51 1417 52 1387 1340 1295

*DEFAULT **NOT RECOMMENDED

22 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 23

PCBBF139 *MEC801205D* - COOLING

DIP SWITCHES S1-1, S1-2, S1-3

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF* Ylo 1627 1566 1520 1470 1420 1398 1391 1343

Y 2226 2165 2126 2083 2048 2011 1983 1945

ON OFF OFF Ylo 815 742 662 590 503 422 362 299

Y 1627 1566 1520 1470 1420 1398 1391 1343

ON ON OFF Ylo 815 742 662 590 503 422 362 299

Y 2226 2165 2126 2083 2048 2011 1983 1945

OFF ON OFF Ylo 1627 1566 1520 1470 1420 1398 1391 1343

Y 1381 1324 1274 1220 1164 1137 1109 1049

OFF OFF ON Ylo 1627 1566 1520 1470 1420 1398 1391 1343

Y 1831 1770 1723 1677 1630 1590 1547 1506

OFF ON ON Ylo 815 742 662 590 503 422 362 299

Y 1381 1324 1274 1220 1164 1137 1109 1049

ON OFF ON Ylo 1831 1770 1723 1677 1630 1590 1547 1506

Y 2226 2165 2126 2083 2048 2011 1983 1945

ON ON ON Ylo 1831 1770 1723 1677 1630 1590 1547 1506

Y 815 742 662 590 503 422 362 299

PCBBF139 *MEC801205D* - CONTINOUS FAN

DIP Switches S2-2 S2-3 S2-4

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM

OFF OFF OFF G 1381 1324 1274 1220 1164 1137 1109 1049

ON OFF OFF G 1831 1770 1723 1677 1630 1590 1547 1506

ON ON OFF G 815 742 662 590 503 422 362 299

OFF ON OFF G 1627 1566 1520 1470 1420 1398 1391 1343

OFF OFF ON G 2226 2165 2126 2083 2048 2011 1983 1945

OFF ON ON G 1381 1324 1274 1220 1164 1137 1109 1049

ON OFF ON G 1381 1324 1274 1220 1164 1137 1109 1049

ON ON ON G 1381 1324 1274 1220 1164 1137 1109 1049

PCBBF139 *MEC801205D* - HEATING

DIP Switches S1-4 S2-1

STATIC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

T STAT CALL CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM

OFF OFF* W1 1381 45 1324 47 1274 49 1220 51 1164 53 1137 1109 1049 W2 1831 49 1770 50 1723 52 1677 53 1630 55 1590 1547 1506

ON OFF** W1 815 N/A 742 N/A 662 N/A 590 N/A 503 N/A 422 362 299 W2 1831 N/A 1770 N/A 1723 N/A 1677 N/A 1630 N/A 1590 1547 1506

ON ON** W1 815 N/A 742 N/A 662 N/A 590 N/A 503 N/A 422 362 299 W2 1627 N/A 1566 N/A 1520 N/A 1470 N/A 1420 N/A 1398 1391 1343

OFF ON W1 1627 38 1566 40 1520 41 1470 42 1420 44 1398 1391 1343 W2 2226 40 2165 41 2126 42 2083 43 2048 43 2011 1983 1945

*DEFAULT **NOT RECOMMENDED

GMEC801205D* Airflow Data (cont.)

22 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com 23

Temperature Rise Range Chart

30 40

50 60

70 80

90 11

0 12

0 10

0 13

0 14

0 15

0

10 0

90 80 70 60 50 40 30 20 10

O U

TP U

T B

TU /H

R x

10 00

B TU

O U

TP U

T vs

TE M

P E

R AT

U R

E R

IS E

C H

A R

T TEMPERATURERISE

60 0

C FM

70 0

90 0 10

00 11 00 12

00

14 00

16 00 18

00 20 00 22

00 24 00

C FM

FO R

M U

LA S

B TU

O U

TP U

T =

C FM

x 1.

08 x

R IS

E

R IS

E =

B TU

O U

TP U

T 1.

08

C FM

80 0

Temperature Rise

O ut

pu t

BT U

/h x

1 ,0

00

Fo rm

ul as

BT U

/h O

ut pu

t = C

FM x

1 .0

8 x

Ri se

Ri se

=

BT U

/H O

ut pu

t

CF M

x 1

.0 8

B TU

O ut

pu t

Vs . T

em pe

ra tu

re R

is e

Ch ar

t

24 www.goodmanmfg.com SS-GMEC80/GCEC80 SS-GMEC80/GCEC80 www.goodmanmfg.com PB

Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 2021 Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA.

Wiring Diagram

W iri

ng is

s ub

je ct

to c

ha ng

e. A

lw ay

s re

fe r

to t

he w

iri ng

d ia

gr am

o r

th e

un it

fo r t

he m

os t u

p- to

-d at

e w

iri ng

.

W

ar n in g

Hi gh

V ol

ta ge

: Di

sc on

ne ct

a ll

po w

er b

ef or

e se

rv ic

in g

or i

ns ta

lli ng

t hi

s un

it. M

ul tip

le p

ow er

so

ur ce

s m ay

b e

pr es

en t.

Fa ilu

re to

d o

so m

ay c

au se

p ro

pe rt

y da

m ag

e, p

er so

na l i

nj ur

y, or

d ea

th .

GN

GND

COLOR CODES:

GN GREEN

RD RED GY GRAY

PU PURPLE

PK PINK

BK BLACK

BL BLUE WH WHITE BR BROWN

YL YELLOW OR ORANGE

GND

BK

RD

G N

G N

24VAC

115 VAC

GND

G R

D

BK

YLO Y W1 W2 R G C TWIN N.E.C. CLASS 2 WIRE

0140F02480-A

BR PK

GY

OR

G N

BL

YL

S1

BK

HUM X-FM

RL1 CIRC-H

EAC-H

5

21

4 3

24 V 3 A FUSE

NEUTRAL

DIAGNOSTIC

LED'S

5 CIRCUIT CO NN

ECTO R

10

63

4

52

7

11

1

12

8

9

FUSE 3 A

MICRO TO

PS2 (2)

TR (9)

G

HI

C

TH (5)

24V TH ERM

O STAT CO

NNECTIO N

S N.E.C. CLASS 2 W IRE

VALVE GAS

W2

TRANSFORMER

HLI (6)

Y2

Y1 HLO (11)

GND (4)

O

MVL (7)

NO

W1

C

R

CONTROLS AUTO RESET AUXILIARY LIMIT

LIMIT CONTROLS MANUAL RESET ROLLOUTPRESS. SWTICH

HIGH FIRE

C

SWITCH LOW FIRE PRESS

MVH (1)

DEHUM

GND

PS1 (12)

LIMIT CONTROL AUTO RESET PRIMARY24 VAC

NO

PM

MVC (8)

INTEGRATED CONTROL MODULE

C

BLWR

AIR INDOOR

CIRCULATOR

R TO

MICRO TO

TO +VDC

EAC

HUMIDIFIER

ID

NEUTRAL

WIRING TO UNIT

L INTEG

RATED CO NTRO

L M O

DULE

HOT SURFACE

GND

BLWR

NEUTRAL

WARNING:

GROUNDED.

OVERCURRENT PROTECTION DEVICE

MUST BE PROPERLY

SWITCH

NEUTRAL

ELECTRONIC

AIR

IGN

IND HI

DISCONNECT

FS

POLARIZED AND

NEUTRAL

LINE

NEUTRAL

JUNCTION BOX

BLWR IND LO

N

INDOOR

AIR CLEANER

HUM

DOOR

NEUTRAL

INTEG RATED CO

NTRO L M

O DULE

TO 115VAC/ 1 /60 HZ POWER SUPPLY WITH

115 VAC

HUM-OUT

IGNITER

CIRCULATOR

BEFORE SERVICING.

FLAME SENSOR

DISCONNECT POWER

LINE

GND

T1 T2

O R

BR

BK W H

W H

W H

W H

PU G

Y YL

O R

BR

PK

RD W

H BK PU

G Y

BR

O R

RD

OR

BL RD

W H

W H

LINE

LIMIT CONTROL AUXILIARY AUTO RESET

PK

WARNING:DISCONNECT

TR ANSFO

RM ER

40 VA

PU

N NO

G

C

SWITCH PRESSURE LOW FIRE

SENSOR FLAME

1 ROLL OUT SWITCH SOME UNITS MAY HAVE

C TO UNIT MUST BE

BL

BK

AND GROUNDED.

1

JUNCTIO N

BO X

W H

SWITCH (PRESS.)

FIELD SPLICE FIELD GND

3

G N

BL

BR

W H

NO

LIMIT CONTROL AUTO RESET PRIMARY

WH

1

OR

WH

L

PU

GY

BK

SWITCH ASSEMBLY ID BLOWER TWO-STAGE PRESSURE

OR

WH

SERVICING. WIRING

EQUIPMENT GND

INTERNAL TO

SWITCH PRESSURE HIGH FIRE

PROT. DEVICE

INTEGRATED CONTROL

PK

PU

PLUG CONNECTION

L

N

BK

C

DOOR OPEN) (OPEN WHEN DOOR SWITCH COMPARTMENT BLOWER

SWITCH (TEMP.)

GND

1

BLOWERCIRCULATOR

JUNCTION

OR

40 VA

/60 HZ

DISCONNECT

(WHITE RODGERS) GAS VALVE TWO STAGE

OVERCURRENT

CONNECTOR 2 CIRCUIT

LOW VOLTAGE (24V)

GND

WH

CHASSIS G R

O U

ND2 3

IGNITER SURFACE

HOT

2

YL

PU

2

C

BLOWER DRAFT

INDUCED

BK

PM

BK

BLOWER COMPARTMENT

115 VAC/ 1

OVERCURRENT

BK

HARNESS ECM MTR

HI

TERMINAL

O R

POWER BEFORE

IGNITER

RD

BK

TO

BK

POWER SUPPLY WITH

BURNER COMPARTMENT

PROTECTION DEVICE

PROPERLY POLARIZED

RD BK OR

BL

LOW VOLTAGE FIELD HI VOLTAGE (115V) HI VOLTAGE FIELD

RAPID = TWINNING ERROR

STEADY ON = INTERNAL GV ERROR, MICRO AND FREQUENCY CHECK

1 FLASH = FLAME SENSED WHEN NO FLAME SHOULD BE PRESENT

4 FLASHES = OPEN LIMIT SWITCH

0

4

3

2

1

RED LED FLASH CODE

2 FLASHES = PRESSURE SWITCH STUCK CLOSED/INDUCER ERROR

3 FLASHES = 1ST STAGE PRESSURE SWITCH STUCK OPEN/INDUCER ERROR

5 FLASHES = OPEN ROLLOUT/OPEN FUSE DETECTED

6 FLASHES = PRESSURE SWITCH CYCLE LOCKOUT

7 FLASHES = EXTERNAL LOCKOUT (RETRIES)

9

6

5

7

8 8 FLASHES = EXTERNAL LOCKOUT (RECYCLES)

9 FLASHES + GROUNDING OR REVERSED POLARITY

10 FLASHES = GAS FLOW WITH NO CALL FOR HEAT

11 FLASHES = LIMIT SWITCH OPEN-BLOWER FAILURE

12 FLASHES = IGNITOR RELAY FAILURE

11

10

12

3 DOUBLE FLASHES = 2ND STAGE PRESSURE SWITCH STUCK OPEN/INDUCER ERROR

3 FLASHES = W2 PRESENT WITH NO W1

2 FLASHES = NORMAL OPERATION WITH CALL FOR 2ND STAGE HEAT

1 FLASH = NORMAL OPERATION WITH CALL FOR 1ST STAGE HEAT (W1)

2

4

3

1

4 FLASHES = Y PRESENT WITH NO G CALL, YLO PRESENT WITH NO G CALL

AMBER LED FLASH CODE

RAPID = LOW FLAME SENSE CURRENT

RAPID = NORMAL OPERATION WITH CALL FOR FAN (G) STEADY ON = STANDBY

1 FLASH = NORMAL OPERATION WITH CALL FOR LOW STAGE COOL (YLO + G)

0

2

1

GREEN LED FLASH CODE

2 FLASHES = NORMAL OPERATION WITH CALL FOR HIGH STAGE COOL/ OR SINGLE STAGE COOLING (Y + G)

0

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. NOTES:

$

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.

MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C. USE COPPER CONDUCTORS ONLY.

4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.

5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THER

Manualsnet FAQs

If you want to find out how the GCEC80 Goodman works, you can view and download the Goodman GCEC80 User's Manual on the Manualsnet website.

Yes, we have the User's Manual for Goodman GCEC80 as well as other Goodman manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Manual should include all the details that are needed to use a Goodman GCEC80. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Goodman GCEC80 User's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Goodman GCEC80 User's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Goodman GCEC80 User's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Goodman GCEC80 User's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Goodman GCEC80 User's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.