SS-GM9S80/GC9S80 www.goodmanmfg.com 8/21

Heating Input : 40,000120,000 BTU/h Single-Stage, Multi-Speed ECM, Multi-Position Gas Furnace

80% AFUE

Standard Features Cabinet Features Heavy-duty aluminized-steel dual-

diameter tubular heat exchanger Single-stage gas valve Durable Hot-surface igniter Quiet, single-speed draft induced Self-diagnostic control board Color-coded low-voltage terminals Multi-speed ECM blower motor

California Low NOx emissions models available Can no longer be installed in Californias

South Coast Air Quality Management District (SCAQMD) on or after October 1, 2019.

AHRI Certified; ETL Listed

Installation: GM9S80 -upflow,

horizontal left or right GC9S80- downflow,

horizontal left or right Convenient left or right connection

for gas and electrical service Heavy-gauge steel cabinet with

durable baked-enamel finish Foil faced insulated heat exchanger

Contents Nomenclature ........................................ 2 Product Specifications ........................... 3 Dimensions ............................................ 5 Airflow Data ........................................... 7 Wiring Diagrams .................................. 19 Accessories .......................................... 20 Minimum Filter Sizes .......................... 20

GM9S80/GC9S80

* Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 2-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec.

2 www.goodmanmfg.com SS-GM9S80/GC9S80

Nomenclature

G M 9 C 80 060 3 B N **

1 2 3 4 5,6 7,8,9 10 11 12 13,14

Brand Engineering

G - Goodman Brand Major/Minor Revisions A - Initial Release

B - 1st Revision

Configuration NOx

M - Upflow/Horizontal N = > 40 NG/J NOx

C - Downflow/Horizontal X = < 40 NG/J NOx

U = < 14NG/J NOx

Motor Cabinet Width

9 - Nine Speed ECM A - 14" C - 21"

B - 17" D - 24"

Gas Valve Maximum CFM

S - Single Stage 3 - 1200 CFM 4 - 1600 CFM

C - Two Stage 5 - 2000 CFM

AFUE MBTU/h

80 - 80% AFUE 92 - 92% AFUE 030 - 30,000 BTU/h 080 - 80,000 BTU/hz

96 - 96% AFUE 97 - 97% AFUE 040 - 40,000 BTU/h 100 - 100,000 BTU/h

060 - 60,000 BTU/h 120 - 120,000 BTU/h

SS-GM9S80/GC9S80 www.goodmanmfg.com 3

GM9S80 Product Specifications

GM9S80 0403A*

GM9S80 0603A*

GM9S80 0603B*

GM9S80 0604B*

GM9S80 0803B*

GM9S80 0804B*

GM9S80 0804C*

GM9S80 0805C*

GM9S80 1005C*

GM9S80 1205D*

Heating Capacity

Input 40,000 60,000 60,000 60,000 80,000 80,000 80,000 80,000 100,000 120,000

Natural Gas Output 32,000 48,000 48,000 48,000 64,000 64,000 64,000 64,000 80,000 96,000

LP Gas Output 32,000 48,000 48,000 48,000 64,000 64,000 64,000 64,000 80,000 96,000

AFUE 80 80 80 80 80 80 80 80 80 80

Available AC @ 0.5 ESP 3 3 3 4 3 4 4 5 5 5

Temperature Rise Range (F) 25-55 20-50 20-50 20-50 35-65 35-65 35-65 35-65 35-65 40-70

Circulator Blower

Size (D x W) 10" x 6" 10" x 6" 10" x 8" 10" x 8" 10" x 8" 10" x 8" 10" x 10" 10" x 10" 10" x 10" 10 x 10

Horsepower @1075 RPM 0.5 0.5 0.5 0.75 0.5 0.75 0.75 0.75 0.75 1

Speed 9 9 9 9 9 9 9 9 9 9

Vent Diameter 4" 4" 4" 4" 4" 4" 4" 4" 4" 4"

No. of Burners 2 3 3 3 4 4 4 4 5 6

Electrical Data

Min. Circuit Ampacity 8.7 8.7 8.7 12.45 8.7 12.45 12.45 12.45 12.45 15.3

Max. Overcurrent Device (amps) 15 15 15 15 15 15 15 15 15 20

Ship Weight (lbs) 86 90 100 108 116 120 132 132 132 132

DOE AFUE based upon Isolated Combustion System (ICS) Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code

NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with

National Electrical Codes. Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size.

May use fuses or HACR-type circuit breakers of the same size as noted.

Notes All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all

existing local codes.

4 www.goodmanmfg.com SS-GM9S80/GC9S80

GC9S80 Product Specifications

GC9S80 0403A*

GC9S80 0603A*

GC9S80 0804B*

GC9S80 0805C*

GC9S80 1005C*

Heating Capacity Input 40,000 60,000 80,000 80,000 100,000

Natural Gas Output 32,000 48,000 64,000 64,000 80,000

LP Gas Output 32,000 48,000 64,000 64,000 80,000

AFUE 80 80 80 80 80

Available AC @ 0.5 ESP 3 3 4 5 5

Temperature Rise Range (F) 25-55 30-60 35-65 35-65 40-70

Circulator Blower

Size (D x W) 10" X 6" 10" X 6" 10" X 8" 10" X 10" 10" X 10"

Horsepower @1075 RPM 1/2 1/2 3/4 1 1

Speed 9 9 9 9 9

Vent Diameter 4" 4" 4" 4" 4"

No. of Burners 2 3 4 4 5

Electrical Data

Min. Circuit Ampacity 8.7 8.7 12.45 15.3 15.3

Max. Overcurrent Device (amps) 15 15 15 20 20

Ship Weight (lbs) 90 94 107 115 115

DOE AFUE based upon Isolated Combustion System (ICS) Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel

Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada).

Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accor- dance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code

and/or all existing local codes.

SS-GM9S80/GC9S80 www.goodmanmfg.com 5

GM9S80 Dimensions

28

A B

1

33

23516

1716

13

20

27 Alt. Gas Inlet

Alt. High Voltage

Alt. Low Voltage

Alternate Gas Inlet

High-Voltage Inlet

Low-Voltage Inlet

Alt. Flue Outlet Horizontal Left

19

23

15

Minimum Clearances to Combustible Materials

Sides Rear Front Vent

Top SW B

1 0 3 6 1 1

24 clearance for serviceability recommended. Single Wall Vent (SW) to be used only as a connector. Refer to the latest editions of the National Fuel Gas

Code NFPA 54/ ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada).

Note: AMES80 approved for line contact in the horizontal position.

Model A B Model A B

GM9S800403A* 14 12 GM9S800804B* 17 16 GM9S800603A* 14 12 GM9S800804C* 21 19

GM9S800603B* 17 16 GM9S800805C* 21 19

GM9S800604B* 17 16 GM9S801005C* 21 19

GM9S800803B* 17 16 GM9S801205D* 24 23 Notes Line voltage wiring can enter through the right or left side of furnace.

Low-voltage wiring can enter through the right or left side of furnace. Conversion kits for high-altitude (4500+ ft) natural gas operation are available.

Contact your Goodman distributor or dealer for details. Installer must supply the following gas line fittings, according to which entrance is used:

Left: One 90 street elbow; one 2 pipe nipple; one 90 elbow; straight pipe; one ground joint union Right: Straight pipe to reach gas valve

6 www.goodmanmfg.com SS-GM9S80/GC9S80

GC9S80 Dimensions

Model A B Non-Combustible Floor Base

GC9S800403A* 14 12 SBT14

GC9S800603A* 14 12 SBT14

GC9S800804B* 17 16 SBT17

GC9S800805C* 21 19 SBT17

GC9S801005C* 21 19 SBT21

Notes Line voltage wiring can enter through the right or left side of furnace.

Low-voltage wiring can enter through the right or left side of furnace. Conversion kits for high-altitude (4500+ ft) natural gas operation are avail-

able. Contact your Goodman distributor or dealer for details.

A

B

High-Voltage Electrical

Low-Voltage Electrical

Gas Inlet

19

28

11

18

33

Minimum Clearances to Combustible Materials

Sides Rear Front Vent

Top SW B

1 0 3 6 1 1

24 clearance for serviceability recommended. Single Wall Vent (SW) to be used only as a connector. Refer to the latest editions of the National Fuel Gas

Code NFPA 54/ ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada).

Note: GMES80 approved for line contact in the horizontal position.

SS-GM9S80/GC9S80 www.goodmanmfg.com 7

GM9S80 Low Stage Cooling Airflow Data

Note: ^ DEFAULT SPEED

LOW STAGE COOLING AIFLOW

MODEL THER-

MOSTAT CALL

TAP #

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM CFM CFM CFM CFM CFM CFM CFM

GM9S80 0403A* Y/Y1

F01 658 585 545 495 444 390 332 151

F02 749 697 652 607 554 509 459 406

F03 925 881 840 800 760 721 681 645

F04^ 882 841 800 760 719 678 641 602

F05 1330 1295 1273 1251 1223 1195 1168 1142

F06 1130 1090 1059 1022 991 957 926 895

F07 1158 1113 1090 1057 1024 996 964 935

F08 1270 1235 1208 1179 1147 1119 1088 1060

F09 1417 1380 1359 1336 1314 1288 1261 1238

GM9S80 0603A* Y/Y1

F01 659 599 542 490 437 383 320 N/A

F02 1268 1221 1188 1154 1122 1091 1060 1029

F03 1087 1044 1008 973 938 905 871 841

F04^ 1118 1070 1033 997 963 929 896 865

F05 1308 1262 1224 1197 1167 1141 1117 1089

F06 868 823 780 741 699 662 624 584

F07 922 877 835 795 757 718 679 642

F08 1382 1341 1311 1291 1263 1234 1206 1177

F09 1492 1448 1409 1381 1354 1332 1310 1288

GM9S80 0603B* Y/Y1

F01 720 660 614 542 468 413 359 313

F02 1289 1260 1232 1194 1161 1125 1087 1073

F03 1125 1089 1052 1013 973 947 909 863

F04^ 1252 1198 1153 1110 1069 1028 990 953

F05 922 872 830 786 736 683 616 565

F06 1146 1113 1076 1039 1002 969 933 891

F07 1370 1345 1317 1286 1260 1224 1187 1168

F08 1413 1386 1360 1330 1302 1270 1242 1211

F09 1544 1500 1459 1419 1387 1349 1317 1286

GM9S80 0604B* Y/Y1

F01 764 695 630 559 485 415 358 N/A

F02 1287 1235 1191 1147 1104 1062 1020 979

F03 1339 1301 1258 1217 1174 1131 1090 1048

F04^ 1396 1346 1298 1257 1217 1175 1135 1098

F05 1185 1135 1088 1040 992 947 901 855

F06 1500 1460 1420 1360 1380 1294 1256 1219

F07 1591 1539 1493 1454 1416 1379 1347 1311

F08 1675 1622 1583 1545 1510 1474 1440 1402

F09 1790 1741 1701 1668 1631 1599 1567 1532

GM9S80 0803B* Y/Y1

F01 710 646 580 515 432 367 314 274

F02 1298 1255 1216 1178 1140 1102 1067 1028

F03 1209 1166 1124 1083 1045 1005 964 923

F04^ 1138 1091 1045 1001 959 920 876 832

F05 1391 1352 1314 1278 1241 1209 1175 1140

F06 977 931 880 836 785 734 683 626

F07 1036 985 940 895 848 799 751 705

F08 1456 1414 1376 1341 1302 1270 1238 1200

F09 1533 1488 1452 1415 1383 1350 1317 1286

8 www.goodmanmfg.com SS-GM9S80/GC9S80

GM9S80 Low Stage Cooling Airflow Data (Cont.)

Note: ^ DEFAULT SPEED

LOW STAGE COOLING AIFLOW

MODEL THER-

MOSTAT CALL

TAP #

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM CFM CFM CFM CFM CFM CFM CFM

GM9S80 0804B* Y/Y1

F01 841 657 595 522 439 367 315 N/A

F02 1141 1089 1045 1001 958 914 869 823

F03 1311 1267 1226 1189 1150 1114 1072 1034

F04^ 1395 1347 1309 1270 1233 1199 1164 1125

F05 1490 1447 1407 1373 1336 1303 1269 1237

F06 1553 1510 1469 1435 1401 1368 1335 1300

F07 1593 1548 1508 1474 1440 1409 1376 1343

F08 1776 1735 1695 1661 1628 1601 1570 1542

F09 1853 1812 1773 1739 1708 1679 1650 1623

GM9S80 0804C* Y/Y1

F01 831 750 671 588 501 405 348 300

F02 1214 1158 1103 1045 989 936 883 823

F03 1303 1249 1191 1136 1081 1028 974 928

F04^ 1426 1375 1324 1277 1229 1177 1124 1078

F05 1518 1465 1418 1372 1328 1284 1237 1195

F06 1588 1539 1494 1447 1401 1358 1313 1267

F07 1710 1666 1632 1595 1554 1512 1473 1431

F08 1785 1751 1717 1675 1639 1596 1557 1516

F09 1845 1805 1771 1733 1695 1655 1618 1576

GM9S80 0805C* Y/Y1

F01 837 752 671 576 501 426 361 315

F02 1316 1270 1218 1166 1114 1061 1000 962

F03 1353 1323 1286 1235 1183 1131 1085 1040

F04^ 1587 1544 1506 1459 1416 1372 1323 1281

F05 1731 1673 1632 1587 1546 1506 1463 1421

F06 1794 1744 1709 1671 1632 1591 1555 1513

F07 1861 1805 1761 1720 1681 1642 1603 1565

F08 1910 1873 1839 1798 1761 1723 1686 1648

F09 2110 2055 2035 2003 1973 1946 1907 1890

GM9S80 1005C* Y/Y1

F01 802 724 637 551 468 389 342 294

F02 1405 1356 1308 1262 1210 1182 1155 1102

F03 1574 1531 1484 1440 1392 1357 1306 1256

F04^ 1619 1575 1526 1489 1446 1404 1355 1313

F05 1688 1641 1600 1557 1513 1477 1428 1381

F06 1811 1769 1730 1686 1649 1610 1572 1525

F07 1857 1812 1774 1733 1697 1662 1622 1586

F08 1892 1850 1805 1774 1735 1692 1658 1621

F09 2116 2073 2039 2005 1981 1945 1909 1879

GM9S80 1205D* Y/Y1

F01 851 774 692 615 535 470 411 359

F02 1677 1629 1583 1540 1498 1449 1399 1349

F03 1537 1489 1444 1404 1365 1322 1272 1211

F04^ 1416 1365 1315 1267 1220 1163 1106 1048

F05 1154 1098 1043 983 932 874 819 755

F06 1806 1764 1729 1688 1654 1615 1578 1535

F07 1869 1816 1773 1731 1693 1661 1629 1589

F08 1947 1903 1865 1833 1802 1769 1743 1708

F09 2107 2066 2030 1996 1963 1932 1899 1867

SS-GM9S80/GC9S80 www.goodmanmfg.com 9

Note: ^ DEFAULT SPEED

GM9S80 High Stage Cooling Airflow Data

HIGH STAGE COOLING AIFLOW

MODEL THER-

MOSTAT CALL

TAP #

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM CFM CFM CFM CFM CFM CFM CFM

GM9S80 0403A* Y2

F01 658 585 545 495 444 390 332 151

F02 749 697 652 607 554 509 459 406

F03 925 881 840 800 760 721 681 645

F04 882 841 800 760 719 678 641 602

F05^ 1330 1295 1273 1251 1223 1195 1168 1142

F06 1130 1090 1059 1022 991 957 926 895

F07 1158 1113 1090 1057 1024 996 964 935

F08 1270 1235 1208 1179 1147 1119 1088 1060

F09 1417 1380 1359 1336 1314 1288 1261 1238

GM9S80 0603A* Y2

F01 659 599 542 490 437 383 320 N/A

F02 1268 1221 1188 1154 1122 1091 1060 1029

F03 1087 1044 1008 973 938 905 871 841

F04 1118 1070 1033 997 963 929 896 865

F05^ 1308 1262 1224 1197 1167 1141 1117 1089

F06 868 823 780 741 699 662 624 584

F07 922 877 835 795 757 718 679 642

F08 1382 1341 1311 1291 1263 1234 1206 1177

F09 1492 1448 1409 1381 1354 1332 1310 1288

GM9S80 0603B* Y2

F01 720 660 614 542 468 413 359 313

F02 1289 1260 1232 1194 1161 1125 1087 1073

F03 1125 1089 1052 1013 973 947 909 863

F04 1252 1198 1153 1110 1069 1028 990 953

F05^ 922 872 830 786 736 683 616 565

F06 1146 1113 1076 1039 1002 969 933 891

F07 1370 1345 1317 1286 1260 1224 1187 1168

F08 1413 1386 1360 1330 1302 1270 1242 1211

F09 1544 1500 1459 1419 1387 1349 1317 1286

GM9S80 0604B* Y2

F01 764 695 630 559 485 415 358 N/A

F02 1287 1235 1191 1147 1104 1062 1020 979

F03 1339 1301 1258 1217 1174 1131 1090 1048

F04 1396 1346 1298 1257 1217 1175 1135 1098

F05^ 1185 1135 1088 1040 992 947 901 855

F06 1500 1460 1420 1360 1380 1294 1256 1219

F07 1591 1539 1493 1454 1416 1379 1347 1311

F08 1675 1622 1583 1545 1510 1474 1440 1402

F09 1790 1741 1701 1668 1631 1599 1567 1532

GM9S80 0803B* Y2

F01 710 646 580 515 432 367 314 274

F02 1298 1255 1216 1178 1140 1102 1067 1028

F03 1209 1166 1124 1083 1045 1005 964 923

F04 1138 1091 1045 1001 959 920 876 832

F05^ 1391 1352 1314 1278 1241 1209 1175 1140

F06 977 931 880 836 785 734 683 626

F07 1036 985 940 895 848 799 751 705

F08 1456 1414 1376 1341 1302 1270 1238 1200

F09 1533 1488 1452 1415 1383 1350 1317 1286

10 www.goodmanmfg.com SS-GM9S80/GC9S80

GM9S80 High Stage Cooling Airflow Data (Cont.)

HIGH STAGE COOLING AIFLOW

MODEL THER-

MOSTAT CALL

TAP #

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM CFM CFM CFM CFM CFM CFM CFM

GM9S80 0804B* Y2

F01 841 657 595 522 439 367 315 N/A

F02 1141 1089 1045 1001 958 914 869 823

F03 1311 1267 1226 1189 1150 1114 1072 1034

F04 1395 1347 1309 1270 1233 1199 1164 1125

F05^ 1490 1447 1407 1373 1336 1303 1269 1237

F06 1553 1510 1469 1435 1401 1368 1335 1300

F07 1593 1548 1508 1474 1440 1409 1376 1343

F08 1776 1735 1695 1661 1628 1601 1570 1542

F09 1853 1812 1773 1739 1708 1679 1650 1623

GM9S80 0804C* Y2

F01 831 750 671 588 501 405 348 300

F02 1214 1158 1103 1045 989 936 883 823

F03 1303 1249 1191 1136 1081 1028 974 928

F04 1426 1375 1324 1277 1229 1177 1124 1078

F05^ 1518 1465 1418 1372 1328 1284 1237 1195

F06 1588 1539 1494 1447 1401 1358 1313 1267

F07 1710 1666 1632 1595 1554 1512 1473 1431

F08 1785 1751 1717 1675 1639 1596 1557 1516

F09 1845 1805 1771 1733 1695 1655 1618 1576

GM9S80 0805C* Y2

F01 837 752 671 576 501 426 361 315

F02 1316 1270 1218 1166 1114 1061 1000 962

F03 1353 1323 1286 1235 1183 1131 1085 1040

F04 1587 1544 1506 1459 1416 1372 1323 1281

F05^ 1731 1673 1632 1587 1546 1506 1463 1421

F06 1794 1744 1709 1671 1632 1591 1555 1513

F07 1861 1805 1761 1720 1681 1642 1603 1565

F08 1910 1873 1839 1798 1761 1723 1686 1648

F09 2110 2055 2035 2003 1973 1946 1907 1890

GM9S80 1005C* Y2

F01 802 724 637 551 468 389 342 294

F02 1405 1356 1308 1262 1210 1182 1155 1102

F03 1574 1531 1484 1440 1392 1357 1306 1256

F04 1619 1575 1526 1489 1446 1404 1355 1313

F05^ 1688 1641 1600 1557 1513 1477 1428 1381

F06 1811 1769 1730 1686 1649 1610 1572 1525

F07 1857 1812 1774 1733 1697 1662 1622 1586

F08 1892 1850 1805 1774 1735 1692 1658 1621

F09 2116 2073 2039 2005 1981 1945 1909 1879

GM9S80 1205D* Y2

F01 851 774 692 615 535 470 411 359

F02 1677 1629 1583 1540 1498 1449 1399 1349

F03 1537 1489 1444 1404 1365 1322 1272 1211

F04 1416 1365 1315 1267 1220 1163 1106 1048

F05^ 1154 1098 1043 983 932 874 819 755

F06 1806 1764 1729 1688 1654 1615 1578 1535

F07 1869 1816 1773 1731 1693 1661 1629 1589

F08 1947 1903 1865 1833 1802 1769 1743 1708

F09 2107 2066 2030 1996 1963 1932 1899 1867

Note: ^ DEFAULT SPEEDRECOMMENDED AIRFLOW SPEEDS FOR CONNECTION WITH 2 STAGE OUTDOOR MODELS

FURNACE MODEL Y2 Y1

*M9S800805C* F08 F02

*M9S801205D* F06 F05

SS-GM9S80/GC9S80 www.goodmanmfg.com 11

GM9S80 Circulation Airflow Data

Note: ^ DEFAULT SPEED

CIRCULATION AIFLOW

MODEL THER-

MOSTAT CALL

TAP #

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM CFM CFM CFM CFM CFM CFM CFM

GM9S80 0403A* G

F01 658 585 545 495 444 390 332 151

F02 749 697 652 607 554 509 459 406

F03 925 881 840 800 760 721 681 645

F04 882 841 800 760 719 678 641 602

F05 1330 1295 1273 1251 1223 1195 1168 1142

F06 1130 1090 1059 1022 991 957 926 895

F07 1158 1113 1090 1057 1024 996 964 935

F08 1270 1235 1208 1179 1147 1119 1088 1060

F09 1417 1380 1359 1336 1314 1288 1261 1238

GM9S80 0603A* G

F01 659 599 542 490 437 383 320 N/A

F02 1268 1221 1188 1154 1122 1091 1060 1029

F03 1087 1044 1008 973 938 905 871 841

F04 1118 1070 1033 997 963 929 896 865

F05 1308 1262 1224 1197 1167 1141 1117 1089

F06 868 823 780 741 699 662 624 584

F07 922 877 835 795 757 718 679 642

F08 1382 1341 1311 1291 1263 1234 1206 1177

F09 1492 1448 1409 1381 1354 1332 1310 1288

GM9S80 0603B* G

F01 720 660 614 542 468 413 359 313

F02 1289 1260 1232 1194 1161 1125 1087 1073

F03 1125 1089 1052 1013 973 947 909 863

F04 1252 1198 1153 1110 1069 1028 990 953

F05 922 872 830 786 736 683 616 565

F06 1146 1113 1076 1039 1002 969 933 891

F07 1370 1345 1317 1286 1260 1224 1187 1168

F08 1413 1386 1360 1330 1302 1270 1242 1211

F09 1544 1500 1459 1419 1387 1349 1317 1286

GM9S80 0604B* G

F01 764 695 630 559 485 415 358 N/A

F02 1287 1235 1191 1147 1104 1062 1020 979

F03 1339 1301 1258 1217 1174 1131 1090 1048

F04 1396 1346 1298 1257 1217 1175 1135 1098

F05 1185 1135 1088 1040 992 947 901 855

F06 1500 1460 1420 1360 1380 1294 1256 1219

F07 1591 1539 1493 1454 1416 1379 1347 1311

F08 1675 1622 1583 1545 1510 1474 1440 1402

F09 1790 1741 1701 1668 1631 1599 1567 1532

GM9S80 0803B* G

F01 710 646 580 515 432 367 314 274

F02 1298 1255 1216 1178 1140 1102 1067 1028

F03 1209 1166 1124 1083 1045 1005 964 923

F04 1138 1091 1045 1001 959 920 876 832

F05 1391 1352 1314 1278 1241 1209 1175 1140

F06 977 931 880 836 785 734 683 626

F07 1036 985 940 895 848 799 751 705

F08 1456 1414 1376 1341 1302 1270 1238 1200

F09 1533 1488 1452 1415 1383 1350 1317 1286

12 www.goodmanmfg.com SS-GM9S80/GC9S80

GM9S80 Circulation Airflow Data (Cont.)

Note: ^ DEFAULT SPEED

CIRCULATION AIFLOW

MODEL THER-

MOSTAT CALL

TAP #

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM CFM CFM CFM CFM CFM CFM CFM

GM9S80 0804B* G

F01 841 657 595 522 439 367 315 N/A

F02 1141 1089 1045 1001 958 914 869 823

F03 1311 1267 1226 1189 1150 1114 1072 1034

F04 1395 1347 1309 1270 1233 1199 1164 1125

F05 1490 1447 1407 1373 1336 1303 1269 1237

F06 1553 1510 1469 1435 1401 1368 1335 1300

F07 1593 1548 1508 1474 1440 1409 1376 1343

F08 1776 1735 1695 1661 1628 1601 1570 1542

F09 1853 1812 1773 1739 1708 1679 1650 1623

GM9S80 0804C* G

F01 831 750 671 588 501 405 348 300

F02 1214 1158 1103 1045 989 936 883 823

F03 1303 1249 1191 1136 1081 1028 974 928

F04 1426 1375 1324 1277 1229 1177 1124 1078

F05 1518 1465 1418 1372 1328 1284 1237 1195

F06 1588 1539 1494 1447 1401 1358 1313 1267

F07 1710 1666 1632 1595 1554 1512 1473 1431

F08 1785 1751 1717 1675 1639 1596 1557 1516

F09 1845 1805 1771 1733 1695 1655 1618 1576

GM9S80 0805C* G

F01 837 752 671 576 501 426 361 315

F02 1316 1270 1218 1166 1114 1061 1000 962

F03 1353 1323 1286 1235 1183 1131 1085 1040

F04 1587 1544 1506 1459 1416 1372 1323 1281

F05 1731 1673 1632 1587 1546 1506 1463 1421

F06 1794 1744 1709 1671 1632 1591 1555 1513

F07 1861 1805 1761 1720 1681 1642 1603 1565

F08 1910 1873 1839 1798 1761 1723 1686 1648

F09 2110 2055 2035 2003 1973 1946 1907 1890

GM9S80 1005C* G

F01 802 724 637 551 468 389 342 294

F02 1405 1356 1308 1262 1210 1182 1155 1102

F03 1574 1531 1484 1440 1392 1357 1306 1256

F04 1619 1575 1526 1489 1446 1404 1355 1313

F05 1688 1641 1600 1557 1513 1477 1428 1381

F06 1811 1769 1730 1686 1649 1610 1572 1525

F07 1857 1812 1774 1733 1697 1662 1622 1586

F08 1892 1850 1805 1774 1735 1692 1658 1621

F09 2116 2073 2039 2005 1981 1945 1909 1879

GM9S80 1205D* G

F01 851 774 692 615 535 470 411 359

F02 1677 1629 1583 1540 1498 1449 1399 1349

F03 1537 1489 1444 1404 1365 1322 1272 1211

F04 1416 1365 1315 1267 1220 1163 1106 1048

F05 1154 1098 1043 983 932 874 819 755

F06 1806 1764 1729 1688 1654 1615 1578 1535

F07 1869 1816 1773 1731 1693 1661 1629 1589

F08 1947 1903 1865 1833 1802 1769 1743 1708

F09 2107 2066 2030 1996 1963 1932 1899 1867

SS-GM9S80/GC9S80 www.goodmanmfg.com 13

GM9S80 Heating Airflow Data

HEATING AIFLOW

MODEL THER-

MOSTAT CALL

TAP #

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1 0.2 0.3 0.4 0.5

CFM RISE CFM RISE CFM RISE CFM RISE CFM

GM9S80 0403A* W/W1

F01^^ 658 N/A 585 N/A 545 N/A 495 N/A 444

F02^ 749 40 697 42 652 45 607 49 554

F03 925 32 881 34 840 35 800 37 760

F04 882 34 841 35 800 37 760 39 719

GM9S80 0603A* W/W1

F01^^ 659 N/A 599 N/A 542 N/A 490 N/A 437

F02^ 1268 35 1221 36 1188 37 1154 38 1122

F03 1087 41 1044 43 1008 44 973 46 938

F04 1118 40 1070 42 1033 43 997 45 963

GM9S80 0603B* W/W1

F01^^ 720 N/A 660 N/A 614 N/A 542 N/A 468

F02^ 1289 34 1260 35 1232 36 1194 37 1161

F03 1125 40 1089 41 1052 42 1013 44 973

F04 1252 36 1198 37 1153 39 1110 40 1069

GM9S80 0604B* W/W1

F01^^ 764 N/A 695 N/A 630 N/A 559 N/A 485

F02^ 1287 35 1235 36 1191 37 1147 39 1104

F03 1339 33 1301 34 1258 35 1217 37 1174

F04 1396 32 1346 33 1298 34 1257 35 1217

GM9S80 0803B* W/W1

F01^^ 710 N/A 646 N/A 580 N/A 515 N/A 432

F02^ 1298 46 1255 47 1216 49 1178 50 1140

F03 1209 49 1166 51 1124 53 1083 55 1045

F04 1138 52 1091 54 1045 57 1001 59 959

GM9S80 0804B* W/W1

F01^^ 841 N/A 657 N/A 595 N/A 522 N/A 439

F02^ 1141 52 1089 54 1045 57 1001 59 958

F03 1311 45 1267 47 1226 48 1189 50 1150

F04 1395 42 1347 44 1309 45 1270 47 1233

GM9S80 0804C* W/W1

F01^^ 831 N/A 750 N/A 671 N/A 588 N/A 501

F02^ 1214 49 1158 51 1103 54 1045 57 989

F03 1303 45 1249 47 1191 50 1136 52 1081

F04 1426 42 1375 43 1324 45 1277 46 1229

GM9S80 0805C* W/W1

F01^^ 837 N/A 752 N/A 671 N/A 576 N/A 501

F02^ 1316 45 1270 47 1218 49 1166 51 1114

F03 1353 44 1323 45 1286 46 1235 48 1183

F04 1587 37 1544 38 1506 39 1459 41 1416

GM9S80 1005C* W/W1

F01^^ 802 N/A 724 N/A 637 N/A 551 N/A 468

F02^ 1405 53 1356 55 1308 57 1262 59 1210

F03 1574 47 1531 48 1484 50 1440 51 1392

F04 1619 46 1575 47 1526 49 1489 50 1446

GM9S80 1205D* W/W1

F01^^ 851 N/A 774 N/A 692 N/A 615 N/A 535

F02^ 1677 53 1629 55 1583 56 1540 58 1498

F03 1537 58 1489 60 1444 62 1404 63 1365

F04^^ 1416 N/A 1365 N/A 1315 N/A 1267 N/A 1220

Note: ^ DEFAULT SPEED ^^NOT RECOMMENDED FOR HEATING

14 www.goodmanmfg.com SS-GM9S80/GC9S80

GC9S80 Low Stage Cooling Airflow Data

Note: ^ DEFAULT SPEED

LOW STAGE COOLING AIFLOW

MODEL THER-

MOSTAT CALL

TAP #

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM CFM CFM CFM CFM CFM CFM CFM

GC9S80 0403A* Y/Y1

F01 712 663 610 559 514 462 395 337

F02 1120 1081 1053 1022 990 955 918 887

F03 929 891 858 815 772 737 699 664

F04^ 1073 1031 1003 969 922 891 854 822

F05 1212 1198 1161 1138 1103 1076 1037 1007

F06 871 830 789 743 702 665 628 583

F07 825 784 741 694 650 609 563 520

F08 1274 1252 1220 1195 1169 1145 1110 1084

F09 1362 1342 1307 1273 1252 1237 1211 1185

GC9S80 0603A* Y/Y1

F01 706 655 604 555 505 455 395 328

F02 1035 991 951 913 876 844 807 770

F03 932 887 844 806 767 728 689 651

F04^ 897 851 808 764 725 686 646 603

F05 1123 1077 1041 1006 973 941 907 875

F06 1155 1113 1074 1039 1006 974 945 913

F07 1255 1214 1181 1147 1116 1087 1056 1028

F08 1388 1331 1298 1266 1235 1207 1179 1151

F09 1421 1380 1348 1318 1289 1262 1233 1207

GC9S80 0804B* Y/Y1

F01 760 697 636 569 481 402 349 300

F02 1286 1238 1196 1157 1117 1077 1036 998

F03 1393 1348 1308 1270 1230 1196 1158 1123

F04^ 1459 1414 1371 1336 1297 1264 1229 1193

F05 1753 1713 1677 1642 1611 1576 1549 1518

F06 1309 1261 1218 1182 1142 1103 1064 1025

F07 1580 1534 1495 1459 1429 1390 1356 1324

F08 1523 1483 1438 1403 1370 1336 1299 1266

F09 1643 1599 1562 1525 1491 1462 1431 1394

GC9S80 0805C* Y/Y1

F01 1022 813 674 585 511 431 334 282

F02 1453 1407 1332 1259 1190 1143 1064 1003

F03 1176 1105 1020 935 864 797 729 673

F04^ 1710 1660 1613 1560 1505 1424 1353 1296

F05 1843 1786 1747 1690 1643 1575 1497 1435

F06 1859 1819 1779 1734 1691 1641 1593 1520

F07 2028 1982 1946 1907 1861 1814 1749 1683

F08 2096 2045 2006 1974 1927 1882 1818 1765

F09 2203 2170 2138 2113 2074 2032 1990 1948

GC9S80 1005C* Y/Y1

F01 956 777 675 587 468 377 324 296

F02 1460 1404 1350 1299 1251 1203 1150 1098

F03 1561 1499 1441 1385 1336 1289 1243 1197

F04^ 1628 1571 1521 1472 1425 1380 1337 1291

F05 1714 1659 1611 1564 1519 1473 1432 1387

F06 1833 1784 1735 1688 1645 1605 1562 1520

F07 1899 1853 1804 1761 1720 1681 1640 1602

F08 1926 1894 1849 1807 1764 1720 1683 1642

F09 2222 2174 2132 2090 2053 2013 1976 1944

SS-GM9S80/GC9S80 www.goodmanmfg.com 15

GC9S80 High Stage Cooling Airflow Data

LOW STAGE COOLING AIFLOW

MODEL THER-

MOSTAT CALL

TAP #

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM CFM CFM CFM CFM CFM CFM CFM

GC9S80 0403A* Y2

F01 712 663 610 559 514 462 395 337

F02 1120 1081 1053 1022 990 955 918 887

F03 929 891 858 815 772 737 699 664

F04 1073 1031 1003 969 922 891 854 822

F05^ 1212 1198 1161 1138 1103 1076 1037 1007

F06 871 830 789 743 702 665 628 583

F07 825 784 741 694 650 609 563 520

F08 1274 1252 1220 1195 1169 1145 1110 1084

F09 1362 1342 1307 1273 1252 1237 1211 1185

GC9S80 0603A* Y2

F01 706 655 604 555 505 455 395 328

F02 1035 991 951 913 876 844 807 770

F03 932 887 844 806 767 728 689 651

F04 897 851 808 764 725 686 646 603

F05^ 1123 1077 1041 1006 973 941 907 875

F06 1155 1113 1074 1039 1006 974 945 913

F07 1255 1214 1181 1147 1116 1087 1056 1028

F08 1388 1331 1298 1266 1235 1207 1179 1151

F09 1421 1380 1348 1318 1289 1262 1233 1207

GC9S80 0804B* Y2

F01 760 697 636 569 481 402 349 300

F02 1286 1238 1196 1157 1117 1077 1036 998

F03 1393 1348 1308 1270 1230 1196 1158 1123

F04 1459 1414 1371 1336 1297 1264 1229 1193

F05^ 1753 1713 1677 1642 1611 1576 1549 1518

F06 1309 1261 1218 1182 1142 1103 1064 1025

F07 1580 1534 1495 1459 1429 1390 1356 1324

F08 1523 1483 1438 1403 1370 1336 1299 1266

F09 1643 1599 1562 1525 1491 1462 1431 1394

GC9S80 0805C* Y2

F01 1022 813 674 585 511 431 334 282

F02 1453 1407 1332 1259 1190 1143 1064 1003

F03 1176 1105 1020 935 864 797 729 673

F04 1710 1660 1613 1560 1505 1424 1353 1296

F05^ 1843 1786 1747 1690 1643 1575 1497 1435

F06 1859 1819 1779 1734 1691 1641 1593 1520

F07 2028 1982 1946 1907 1861 1814 1749 1683

F08 2096 2045 2006 1974 1927 1882 1818 1765

F09 2203 2170 2138 2113 2074 2032 1990 1948

GC9S80 1005C* Y2

F01 956 777 675 587 468 377 324 296

F02 1460 1404 1350 1299 1251 1203 1150 1098

F03 1561 1499 1441 1385 1336 1289 1243 1197

F04 1628 1571 1521 1472 1425 1380 1337 1291

F05^ 1714 1659 1611 1564 1519 1473 1432 1387

F06 1833 1784 1735 1688 1645 1605 1562 1520

F07 1899 1853 1804 1761 1720 1681 1640 1602

F08 1926 1894 1849 1807 1764 1720 1683 1642

F09 2222 2174 2132 2090 2053 2013 1976 1944

Note: ^ DEFAULT SPEEDRECOMMENDED AIRFLOW SPEEDS FOR CONNECTION WITH 2 STAGE OUTDOOR MODELS

FURNACE MODEL Y2 Y1

*C9S800805C* F08 F02

16 www.goodmanmfg.com SS-GM9S80/GC9S80

GC9S80 Circulation Airflow Data

Note: ^ DEFAULT SPEED

CIRCULATION AIFLOW

MODEL THER-

MOSTAT CALL

TAP #

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM CFM CFM CFM CFM CFM CFM CFM

GC9S80 0403A* G

F01 712 663 610 559 514 462 395 337

F02 1120 1081 1053 1022 990 955 918 887

F03 929 891 858 815 772 737 699 664

F04 1073 1031 1003 969 922 891 854 822

F05 1212 1198 1161 1138 1103 1076 1037 1007

F06 871 830 789 743 702 665 628 583

F07 825 784 741 694 650 609 563 520

F08 1274 1252 1220 1195 1169 1145 1110 1084

F09 1362 1342 1307 1273 1252 1237 1211 1185

GC9S80 0603A* G

F01 706 655 604 555 505 455 395 328

F02 1035 991 951 913 876 844 807 770

F03 932 887 844 806 767 728 689 651

F04 897 851 808 764 725 686 646 603

F05 1123 1077 1041 1006 973 941 907 875

F06 1155 1113 1074 1039 1006 974 945 913

F07 1255 1214 1181 1147 1116 1087 1056 1028

F08 1388 1331 1298 1266 1235 1207 1179 1151

F09 1421 1380 1348 1318 1289 1262 1233 1207

GC9S80 0804B* G

F01 760 697 636 569 481 402 349 300

F02 1286 1238 1196 1157 1117 1077 1036 998

F03 1393 1348 1308 1270 1230 1196 1158 1123

F04 1459 1414 1371 1336 1297 1264 1229 1193

F05 1753 1713 1677 1642 1611 1576 1549 1518

F06 1309 1261 1218 1182 1142 1103 1064 1025

F07 1580 1534 1495 1459 1429 1390 1356 1324

F08 1523 1483 1438 1403 1370 1336 1299 1266

F09 1643 1599 1562 1525 1491 1462 1431 1394

GC9S80 0805C* G

F01 1022 813 674 585 511 431 334 282

F02 1453 1407 1332 1259 1190 1143 1064 1003

F03 1176 1105 1020 935 864 797 729 673

F04 1710 1660 1613 1560 1505 1424 1353 1296

F05 1843 1786 1747 1690 1643 1575 1497 1435

F06 1859 1819 1779 1734 1691 1641 1593 1520

F07 2028 1982 1946 1907 1861 1814 1749 1683

F08 2096 2045 2006 1974 1927 1882 1818 1765

F09 2203 2170 2138 2113 2074 2032 1990 1948

GC9S80 1005C* G

F01 956 777 675 587 468 377 324 296

F02 1460 1404 1350 1299 1251 1203 1150 1098

F03 1561 1499 1441 1385 1336 1289 1243 1197

F04 1628 1571 1521 1472 1425 1380 1337 1291

F05 1714 1659 1611 1564 1519 1473 1432 1387

F06 1833 1784 1735 1688 1645 1605 1562 1520

F07 1899 1853 1804 1761 1720 1681 1640 1602

F08 1926 1894 1849 1807 1764 1720 1683 1642

F09 2222 2174 2132 2090 2053 2013 1976 1944

SS-GM9S80/GC9S80 www.goodmanmfg.com 17

GC9S80 Heating Airflow Data

HEATING AIFLOW

MODEL THER-

MOSTAT CALL

TAP #

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1 0.2 0.3 0.4 0.5

CFM RISE CFM RISE CFM RISE CFM RISE CFM

GC9S80 0403A* W/W1

F01^^ 712 N/A 663 N/A 610 N/A 559 N/A 514

F02^ 1120 26 1081 27 1053 28 1022 29 990

F03 929 32 891 33 858 35 815 36 772

F04 1073 28 1031 29 1003 30 969 31 922

GC9S80 0603A* W/W1

F01^^ 706 N/A 655 N/A 604 N/A 555 N/A 505

F02^ 1035 43 991 45 951 47 913 49 876

F03 932 48 887 50 844 53 806 55 767

F04^^ 897 N/A 851 N/A 808 N/A 764 N/A 725

GC9S80 0804B* W/W1

F01^^ 760 N/A 697 N/A 636 N/A 569 N/A 481

F02^ 1286 46 1238 48 1196 50 1157 51 1117

F03 1393 43 1348 44 1308 45 1270 47 1230

F04 1459 41 1414 42 1371 43 1336 44 1297

GC9S80 0805C* W/W1

F01^^ 1022 N/A 813 N/A 674 N/A 585 N/A 511

F02^ 1453 41 1407 42 1332 45 1259 47 1190

F03^^ 1176 N/A 1105 N/A 1020 N/A 935 N/A 864

F04 1710 35 1660 36 1613 37 1560 38 1505

GC9S80 1005C* W/W1

F01^^ 956 N/A 777 N/A 675 N/A 587 N/A 468

F02^ 1460 51 1404 53 1350 55 1299 57 1251

F03 1561 47 1499 49 1441 51 1385 53 1336

F04 1628 46 1571 47 1521 49 1472 50 1425

Note: ^ DEFAULT SPEED ^^NOT RECOMMENDED FOR HEATING

18 www.goodmanmfg.com SS-GM9S80/GC9S80

Temperature Rise Range Chart

30 40

50 60

70 80

90 11

0 12

0 10

0 13

0 14

0 15

0

10 0 90 80 70 60 50 40 30 20 10

O U

TP U

T BT

U /H

R x

10 00

BT U

O U

TP U

T vs

TE M

PE R

AT U

R E

R IS

E C

H AR

T TEMPERATURERISE

60 0

C FM

70 0

90 0 10

00 11 00 12

00

14 00

16 00 18

00 20 00 22

00 24 00

C FM

FO R

M U

LA S

B TU

O U

TP U

T =

C FM

x 1.

08 x

R IS

E

R IS

E =

BT U

O U

TP U

T 1.

08

C FM

80 0

Temperature Rise

Fo rm

ul as

BT U

/h O

ut pu

t = C

FR M

x 1

.0 8

x Ri

se

Ri se

=

BT U

/H O

ut pu

t

C FM

CF M

x 1

.0 8

B TU

/h O

ut pu

t Vs

. T em

pe ra

tu re

R is

e Ch

ar t

O ut

pu t

BT U

/h x

1 ,0

00

SS-GM9S80/GC9S80 www.goodmanmfg.com 19

Wiring Diagram

W iri

ng is

su bj

ec t t

o ch

an ge

. A lw

ay s

re fe

r to

th e

w iri

ng d

ia gr

am o

n th

e un

it fo

r t he

m os

t u p-

to -d

at e

w iri

ng .

W ar

ni ng

Hi gh

V ol

ta ge

: Di

sc on

ne ct

a ll

po w

er b

ef or

e se

rv ic

in g

or in

st al

lin g

th is

un it.

M ul

tip le

p ow

er

so ur

ce s m

ay b

e pr

es en

t. Fa

ilu re

to d

o so

m ay

ca us

e pr

op er

ty d

am ag

e, p

er so

na l i

nj ur

y, or

d ea

th .

GN

GND

RD

G N

24VAC

115 VAC

GND

G R

D

0140F02640-A

BK EAC

HUMIDIFIER

ID

NEUTRAL

WIRING TO UNIT

L

INTEG RATED CO

NTRO L M

O DULE

HOT SURFACE

GND

BLWR

NEUTRAL

WARNING:

GROUNDED.

OVERCURRENT PROTECTION DEVICE

MUST BE PROPERLY

SWITCH

NEUTRAL

ELECTRONIC

AIR

IGN

IND

DISCONNECT

FS

POLARIZED AND

NEUTRAL

LINE

NEUTRAL

JUNCTION BOX

BLWR IND LO

N

INDOOR

AIR CLEANER

HUM

DOOR

NEUTRAL

INTEG RATED CO

NTRO L M

O DULE

TO 115VAC/ 1 /60 HZ POWER SUPPLY WITH

115 VAC

HUM-OUT

IGNITER

CIRCULATOR

BEFORE SERVICING.

FLAME SENSOR

DISCONNECT POWER

LINE

BR

W H

G Y

YL

PK

G Y

LIMIT CONTROL AUXILIARY AUTO RESET

PK

WARNING:DISCONNECT

40 VA TR

ANSFO RM

ER

N

G

C

SENSOR FLAME

1 ROLL OUT SWITCH SOME UNITS MAY HAVE

TO UNIT MUST BE

PU

BK

AND GROUNDED.

JUNCTIO N

BO X

W H

BL

BR

NO

LIMIT CONTROL AUTO RESET PRIMARY

WH

1

L

GY

BK

ID BLOWER PRESSURE SWITCH

SERVICING. WIRING

PK

RD

L

N

DOOR OPEN) (OPEN WHEN DOOR SWITCH COMPARTMENT BLOWER

GND

BLOWERCIRCULATOR

/60 HZ

DISCONNECT

GAS VALVE

OVERCURRENT

CONNECTOR 2 CIRCUIT

WH

CHASSIS GROUND

IGNITER SURFACE

HOT

2

YL

C

BLOWER DRAFT

INDUCED

BK

BLOWER COMPARTMENT

115 VAC/ 1

BK

ECM MTR HARNESS

POWER BEFORE

BK

TO

POWER SUPPLY WITH

BURNER COMPARTMENT

PROTECTION DEVICE

PROPERLY POLARIZED

NOTES: 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105v C. USE COPPER CONDUCTORS ONLY. 4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. 5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS)

COLOR CODES: PK PINK BR BROWN WH WHITE BL BLUE GY GRAY RD RED YL YELLOW OR ORANGE PU PURPLE GN GREEN BK BLACK

123

456

789

101112

READ CODES FROM LEFT TO RIGHT

EAC-H

XFM R-H

CIRC-H

LINE-H

E2 0

E3 9

E2E1

E15

E8E5

E4E3

E7

E6

LE FT

C EN

TE R

R IG

H T SW331313 SW1 R223

SW2

6 R226

RD

BL

RD

YL YL

BK

BK

BK

W H

W HW

H

G Y

O R

G N

PU

PU PU

NEUT2 NEUT1 CIRC-N EAC-N HUM

-N XFM

R-N

LINE-N

GND

MICRO TO

TR (7)

G

C

C

TH (3)

24V TH ERM

O STAT CO

NNECTIO N

S N.E.C. CLASS 2 W IRE

VALVE GAS

HLI (8) Y2

Y1

RLO (6)

O MV (10)

W1

R MANUAL RESET ROLLOUT LIMIT SWITCH

PRESS. SWITCH

C

DEHUM

PS1(5)

AUTO RESET PRIMARY LIMIT

24 VAC

NO

HI

MVC (11)

BLWR

AIR INDOOR

CIRCULATOR

R TO

MICRO TO

TO +VDC

INTERGRATED CONTROL MODULE

RLI (12) AUTO RESET AUX LIMIT

HLO (1)

Seven Segment DisplayError Code Status Seg#3 Seg#2 Seg#1 Internal Faults or IRQ Loss E E E Lockout Due to Excessive Retries or Recycles E E 0 Pressure Switch Stuck Closed E E 1 Pressure Switch Open E E 2 Open High Limit Switch E E 3 Flame Detected When no Flame Should be Present E E 4 Open Fuse E E 5 Low Flame Signal E E 6 Ignitor Relay Fault E E L Reversed Line Polarity or Grounding Error E E A Internal Gas Valve Error E E b External Gas Valve Error E E C Open Rollout Switch E 1 1 Ignitor Open E E n Inducer Relay Error E E j TWIN Error E E H

RD

C

HI

1 2

BK BK

BK

W H

W H

W H

W H

Grounding Error E 1 0

5

21

4 3

RD BK

OR BL

YL

RD BL

OR BK

YL

T1

T2

T3

T4

T5

COMRD

SWITCH (PRESS.)

FIELD SPLICE FIELD GND

EQUIPMENT GND

INTERNAL TO

PROT. DEVICE

INTEGRATED CONTROL PLUG CONNECTION

SWITCH (TEMP.)

JUNCTION

LOW VOLTAGE (24V)

OVERCURRENT

TERMINAL

IGNITER

LOW VOLTAGE FIELD HI VOLTAGE (115V) HI VOLTAGE FIELD

GND

GND

TW IN

24 V

H U

M

E21

E24

W/W1 R Y/Y1G C Y2

TRANSFORMER 40 VA

20 www.goodmanmfg.com SS-GM9S80/GC9S80

Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 2021 Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA.

Accessories

Model Description GM9S80 0403A*

GM9S80 0603A*

GM9S80 0603B*

GM9S80 0604B*

GM9S80 0803B*

GM9S80 0804B*

GM9S80 0804C*

GM9S80 0805C*

GM9S80 1005C*

GM9S80 1205D*

AFE18-60A Fossil Fuel (Dual Fuel) Kit

HANG20 High-Altitude Natural Gas Kit

LPLP03 Low LP Gas Pressure Switch

LPT-03 LP Conversion Kits

MVK-01 * Masonry Vent Kit

MVK-02 * Masonry Vent Kit (for 120k model only)

Model Description GC9S80 0403A*B

GC9S80 0603A*B

GC9S80 0804B*B

GC9S80 0805C*

GC9S80 1005C*B

SBT14 Downflow Sub-Base 14"

SBT17 Downflow Sub-Base 17.5"

SBT21 Downflow Sub-Base 21"

AFE18-60A Fossil Fuel (Dual Fuel) Kit

HANG20 High-Altitude Natu- ral Gas Kit

LPLP03 Low LP Gas Pressure Switch

LPT-03 LP Conversion Kits

Minimum Filter Sizes

Model # GM9S80 0403A*

GM9S80 0603A*

GM9S80 0604B*

GM9S80 0804B*

GM9S80 0805C*

GM9S80 81005C*

GM9S80 1205D*

Filter Size (in) (1) 16 x 25 (Side) or (1) 14 x 24 (Bottom) (1) 16 x 25 (Side or Bottom) (1) 16 x 25

(Side or Bottom) (2) 16 x 25 (Side) or (1) 20 x 25 (Bottom)

(2) 16 x 25 (Side) or (1) 24 x 24 (Bottom)

Model # GC9S80 0403A*

GC9S80 0603A*

GC9S80 0804B*

GC9S80 1005C*

Filter Size (in) (2) 10 x 20 or (1) 14 x 25 (Top Return)

(2) 14xX 20 or (1) 16 x 25 (Top Return)

(2) 14 x 20 or (1) 20 x 25 (Top Return)

Model # GC9S80 0403A*

GC9S80 0604B*

GC9S80 0805C*

Filte

Manualsnet FAQs

If you want to find out how the GC9S80 Goodman works, you can view and download the Goodman GC9S80 v2 User's Manual on the Manualsnet website.

Yes, we have the User's Manual for Goodman GC9S80 as well as other Goodman manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Manual should include all the details that are needed to use a Goodman GC9S80. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Goodman GC9S80 v2 User's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Goodman GC9S80 v2 User's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Goodman GC9S80 v2 User's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Goodman GC9S80 v2 User's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Goodman GC9S80 v2 User's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.