SS-GC9C96 www.goodmanmfg.com 9/21

Standard Features Cabinet Features Energy-efficient, multi-speed ECM blower motor Heavy-duty, aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Two-stage gas valve provides quiet, economical heating Durable Silicon Nitride igniter Quiet two-speed induced draft blower Self-diagnostic control board with constant

memory fault code history output to a LED Color-coded low-voltage terminals with provisions

for electronic air cleaner and humidifier Low continuous fan speed options offer quiet air circulation All models comply with California 40 ng/J

Low NOx emissions standard Can no longer be installed in Californias South Coast

Air Quality Management District (SCAQMD) on or after October 1, 2019.

AHRI Certified; ETL Listed

Designed for multi-position installation down flow, horizontal left or right

Certified for direct vent (2-pipe) or non-direct vent (1-pipe)

Easy-to-install top venting with optional side venting Convenient left or right connection

for gas and electrical service Cabinet air leakage (QLeak) 2% Heavy-gauge steel cabinet with durable finish Fully insulated heat exchanger and blower section Airtight solid bottom or side return with easy-cut tabs

for effortless removal in bottom air-inlet applications

Contents Nomenclature ........................................ 2 Product Specifications ........................... 3 Dimensions ............................................ 4 Airflow Specifications ............................ 5 Wiring Diagrams .................................. 10 Accessories .......................................... 11

Two-Stage, Multi-Speed ECM Gas Furnace

Up to 96% AFUE

GC9C96 Heating Input: 40,000100,000 BTU/h

* Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Qubec.

2 www.goodmanmfg.com SS-GC9C96 SS-GC9C96 www.goodmanmfg.com 3

Nomenclature

G C 9 C 96 040 4 C * **

1 2 3 4 5,6 7,8,9 10 11 12 13,14

Brand Engineering

G - Goodman Brand Major/Minor Revisions A - Initial Release

B - 1st Revision

Configuration NOx

M - Upflow/Horizontal N = > 40 NG/J NOx

C - Downflow/Horizontal X = < 40 NG/J NOx

Motor Cabinet Width

9 - Nine Speed ECM A - 14" C - 21"

B - 17" D - 24"

Gas Valve Maximum CFM

C - 2 Stage 3 - 1200 CFM 4 - 1600 CFM

5 - 2000 CFM

AFUE MBTU/h

80 - 80% AFUE 92 - 92% AFUE 030 - 30,000 BTU/h 080 - 80,000 BTU/h

96 - 96% AFUE 97 - 97% AFUE 040 - 40,000 BTU/h 100 - 100,000 BTU/h

060 - 60,000 BTU/h 120 - 120,000 BTU/h

2 www.goodmanmfg.com SS-GC9C96 SS-GC9C96 www.goodmanmfg.com 3

Product Specifications

GC9C96 0403BNA

GC9C96 0603BNA

GC9C96 0803BNA

GC9C96 1005CNA

Heating Data

High Fire Input 40,000 60,000 80,000 100,000

High Fire Output 38,400 57,600 76,800 96,000

Low-Fire Input 28,000 42,000 56,000 70,000

Low-Fire Output 26,880 40,320 53,760 67,200

AFUE 96 96 96 96

Temp. Rise Range (F) 25 - 55 25 - 55 40 - 70 35 - 65

Vent Diameter 2" - 3" 2" - 3" 2" - 3" 2" - 3"

No. of Burners 2 3 4 5

Circulator Blower

Available AC @ 0.5" ESP 1.5 - 3 1.5 - 3 1.5 - 3 3 - 5

Size (D x W) 10" x 8" 11" x 8" 11" x 8" 11" x 10"

Horsepower @ 1075 RPM 1/2 1/2 1/2 1

Speed 9 9 9 9

Electrical Data

Min. Circuit Ampacity 8 8 8 13.3

Max. Overcurrent (amps) 15 15 15 20

Shipping Weight (lbs) 112 115 118 140

Natural Gas BTU/h DOE AFUE based upon Isolated Combustion System (ICS) Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2 or 3 in diameter, depending upon

furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2 or 3 diameter PVC.

Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues. For servicing or cleaning, a 24 front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed

above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.

4 www.goodmanmfg.com SS-GC9C96 SS-GC9C96 www.goodmanmfg.com 5

Dimensions

Air Discharge

Air Return

Model A B C D E

GC9C960403BNA 17" 16" 13" 12" 13"

GC9C960603BNA 17" 16" 13" 12" 13"

GC9C960803BNA 17 16 13 12 13

GC9C961005CNA 21" 19" 17" 16" 17"

A

34

4

11

14

25

28

C

6 6

11

14

14

25

3 2

2

1

2

23

14

1

1

1

E

D Unfolded Flanges

18 Unfolded Flanges

20 Folded Flanges

2

1

2

6

2

Front View Right-Side View

Low-Voltage Electrical Outlet

Alternate Gas

High-Voltage Electrical Outlet

Standard Drain Trap Drain Trap Holes

Alternate Gas Supply

Alternate Vent/

High-Voltage Electrical Outlet

Right Side Exterior Drain Trap Holes

Low-Voltage Electrical Outlet

Air Discharge

Air Discharge

Folded Flanges

B

18

Minimum Clearances to Combustible Materials

Position Sides Rear Front Bottom Flue Top

Downflow 0" 0" 3" NC 0" 1"

Horizontal 6" 0" 3" C 0" 6"

C = If placed on combustible floor, the floor MUST be wood ONLY. NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring.

4 www.goodmanmfg.com SS-GC9C96 SS-GC9C96 www.goodmanmfg.com 5

Notes ^ DEFAULT SPEED All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.

GC9C96 Low Stage Cooling Airflow Data

LOW STAGE COOLING AIFLOW

MODEL THER-

MOSTAT CALL

TAP #

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM CFM CFM CFM CFM CFM CFM CFM

*C9C96 0403BN Y/Y1

F01 727 677 623 565 510 455 403 351

F02 923 882 841 798 752 704 660 614

F03 632 574 510 448 388 332 277 234

F04^ 878 839 797 751 701 653 607 561

F05 1106 1076 1044 1010 974 939 899 860

F06 1188 1156 1123 1091 1062 1029 998 964

F07 1237 1205 1174 1145 1115 1081 1050 1016

F08 1281 1252 1222 1195 1163 1134 1104 1071

F09 1382 1354 1327 1302 1276 1246 1219 1190

*C9C96 0603BN Y/Y1

F01 1167 1118 1069 1022 974 928 877 833

F02 1332 1289 1245 1200 1160 1120 1081 1036

F03 680 609 532 460 397 337 252 201

F04^ 903 839 783 719 661 601 546 497

F05 1248 1204 1159 1113 1071 1028 983 943

F06 963 907 852 803 745 689 639 587

F07 1393 1348 1309 1267 1230 1189 1152 1116

F08 1450 1407 1366 1330 1290 1251 1221 1186

F09 1468 1436 1393 1359 1323 1285 1248 1210

*C9C96 0803BN Y/Y1

F01 1167 1124 1087 1040 995 954 916 869

F02 1317 1277 1240 1201 1161 1122 1081 1045

F03 733 669 606 543 482 424 372 300

F04^ 1217 1174 1130 1086 1045 1003 962 925

F05 1300 1263 1225 1186 1142 1099 1062 1023

F06 919 872 820 764 711 658 605 553

F07 1126 1085 1042 998 953 910 866 824

F08 1375 1341 1301 1264 1226 1189 1154 1118

F09 1440 1402 1366 1330 1295 1260 1224 1187

*C9C96 1005CN Y/Y1

F01 1366 1307 1248 1188 1130 1069 1007 938

F02 1833 1785 1736 1688 1640 1593 1543 1497

F03 1295 1230 1168 1105 1044 981 911 843

F04^ 1634 1578 1525 1471 1416 1363 1311 1265

F05 2028 1994 1937 1899 1863 1814 1769 1724

F06 1773 1721 1671 1621 1571 1521 1470 1421

F07 1908 1860 1813 1766 1720 1672 1624 1578

F08 1965 1919 1873 1829 1783 1736 1688 1643

F09 2096 2053 2014 1973 1931 1890 1849 1803

6 www.goodmanmfg.com SS-GC9C96 SS-GC9C96 www.goodmanmfg.com 7

GC9C96 High Stage Cooling Airflow Data

HIGH STAGE COOLING AIFLOW

MODEL THER-

MOSTAT CALL

TAP #

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM CFM CFM CFM CFM CFM CFM CFM

*C9C96 0403BN Y2

F01 727 677 623 565 510 455 403 351

F02 923 882 841 798 752 704 660 614

F03 632 574 510 448 388 332 277 234

F04 878 839 797 751 701 653 607 561

F05^ 1106 1076 1044 1010 974 939 899 860

F06 1188 1156 1123 1091 1062 1029 998 964

F07 1237 1205 1174 1145 1115 1081 1050 1016

F08 1281 1252 1222 1195 1163 1134 1104 1071

F09 1382 1354 1327 1302 1276 1246 1219 1190

*C9C96 0603BN Y2

F01 1167 1118 1069 1022 974 928 877 833

F02 1332 1289 1245 1200 1160 1120 1081 1036

F03 680 609 532 460 397 337 252 201

F04 903 839 783 719 661 601 546 497

F05^ 1248 1204 1159 1113 1071 1028 983 943

F06 963 907 852 803 745 689 639 587

F07 1393 1348 1309 1267 1230 1189 1152 1116

F08 1450 1407 1366 1330 1290 1251 1221 1186

F09 1468 1436 1393 1359 1323 1285 1248 1210

*C9C96 0803BN Y2

F01 1167 1124 1087 1040 995 954 916 869

F02 1317 1277 1240 1201 1161 1122 1081 1045

F03 733 669 606 543 482 424 372 300

F04 1217 1174 1130 1086 1045 1003 962 925

F05^ 1300 1263 1225 1186 1142 1099 1062 1023

F06 919 872 820 764 711 658 605 553

F07 1126 1085 1042 998 953 910 866 824

F08 1375 1341 1301 1264 1226 1189 1154 1118

F09 1440 1402 1366 1330 1295 1260 1224 1187

*C9C96 1005CN Y2

F01 1366 1307 1248 1188 1130 1069 1007 938

F02 1833 1785 1736 1688 1640 1593 1543 1497

F03 1295 1230 1168 1105 1044 981 911 843

F04 1634 1578 1525 1471 1416 1363 1311 1265

F05^ 2028 1994 1937 1899 1863 1814 1769 1724

F06 1773 1721 1671 1621 1571 1521 1470 1421

F07 1908 1860 1813 1766 1720 1672 1624 1578

F08 1965 1919 1873 1829 1783 1736 1688 1643

F09 2096 2053 2014 1973 1931 1890 1849 1803

Notes ^ DEFAULT SPEED All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.

6 www.goodmanmfg.com SS-GC9C96 SS-GC9C96 www.goodmanmfg.com 7

Notes ^ DEFAULT SPEED All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.

GC9C96 Circulation Airflow Data

CIRCULATION AIFLOW

MODEL THER-

MOSTAT CALL

TAP #

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM CFM CFM CFM CFM CFM CFM CFM

*C9C96 0403BN G

F01 727 677 623 565 510 455 403 351

F02 923 882 841 798 752 704 660 614

F03 632 574 510 448 388 332 277 234

F04 878 839 797 751 701 653 607 561

F05 1106 1076 1044 1010 974 939 899 860

F06 1188 1156 1123 1091 1062 1029 998 964

F07 1237 1205 1174 1145 1115 1081 1050 1016

F08 1281 1252 1222 1195 1163 1134 1104 1071

F09 1382 1354 1327 1302 1276 1246 1219 1190

*C9C96 0603BN G

F01 1167 1118 1069 1022 974 928 877 833

F02 1332 1289 1245 1200 1160 1120 1081 1036

F03 680 609 532 460 397 337 252 201

F04 903 839 783 719 661 601 546 497

F05 1248 1204 1159 1113 1071 1028 983 943

F06 963 907 852 803 745 689 639 587

F07 1393 1348 1309 1267 1230 1189 1152 1116

F08 1450 1407 1366 1330 1290 1251 1221 1186

F09 1468 1436 1393 1359 1323 1285 1248 1210

*C9C96 0803BN G

F01 1167 1124 1087 1040 995 954 916 869

F02 1317 1277 1240 1201 1161 1122 1081 1045

F03 733 669 606 543 482 424 372 300

F04 1217 1174 1130 1086 1045 1003 962 925

F05 1300 1263 1225 1186 1142 1099 1062 1023

F06 919 872 820 764 711 658 605 553

F07 1126 1085 1042 998 953 910 866 824

F08 1375 1341 1301 1264 1226 1189 1154 1118

F09 1440 1402 1366 1330 1295 1260 1224 1187

*C9C96 1005CN G

F01 1366 1307 1248 1188 1130 1069 1007 938

F02 1833 1785 1736 1688 1640 1593 1543 1497

F03 1295 1230 1168 1105 1044 981 911 843

F04 1634 1578 1525 1471 1416 1363 1311 1265

F05 2028 1994 1937 1899 1863 1814 1769 1724

F06 1773 1721 1671 1621 1571 1521 1470 1421

F07 1908 1860 1813 1766 1720 1672 1624 1578

F08 1965 1919 1873 1829 1783 1736 1688 1643

F09 2096 2053 2014 1973 1931 1890 1849 1803

8 www.goodmanmfg.com SS-GC9C96 SS-GC9C96 www.goodmanmfg.com 9

GC9C96 Heating Airflow Data

HEATING AIFLOW

MODEL THER-

MOSTAT CALL

TAP #

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM

*C9C96 0403BN

W/W1

F01^ 727 34 677 37 623 40 565 44 510 49 455 403 351

F03^^ 632 N/A 574 N/A 510 N/A 448 N/A 388 N/A 332 277 234

F04 878 28 839 30 797 31 751 33 701 36 653 607 561

W2

F02^ 923 39 882 40 841 42 798 45 752 47 704 660 614

F04 878 41 839 42 797 45 751 47 701 51 653 607 561

F05 1106 32 1076 33 1044 34 1010 35 974 37 939 899 860

*C9C96 0603BN

W/W1

F01^ 1167 32 1118 33 1069 35 1022 37 974 38 928 877 833

F03^^ 680 N/A 609 N/A 532 N/A 460 N/A 397 N/A 337 252 201

F04 903 N/A 839 N/A 783 N/A 719 N/A 661 N/A 601 546 497

W2

F02^ 1332 40 1289 41 1245 43 1200 44 1160 46 1120 1081 1036

F04^^ 903 N/A 839 N/A 783 N/A 719 N/A 661 N/A 601 546 497

F05 1248 43 1204 44 1159 46 1113 48 1071 50 1028 983 943

*C9C96 0803BN

W/W1

F01^ 1167 43 1124 44 1087 46 1040 48 995 50 954 916 869

F03^^ 733 N/A 669 N/A 606 N/A 543 N/A 482 N/A 424 372 300

F04 1217 41 1174 42 1130 44 1086 46 1045 48 1003 962 925

W2

F02^ 1317 54 1277 56 1240 57 1201 59 1161 61 1122 1081 1045

F04 1217 58 1174 61 1130 63 1086 65 1045 68 1003 962 925

F05 1300 55 1263 56 1225 58 1186 60 1142 62 1099 1062 1023

*C9C96 1005CN

W/W1

F01^ 1366 46 1307 48 1248 50 1188 52 1130 55 1069 1007 938

F03^^ 1295 48 1230 51 1168 53 1105 56 1044 58 981 911 843

F04 1634 N/A 1578 N/A 1525 N/A 1471 N/A 1416 N/A 1363 1311 1265

W2

F02^ 1833 48 1785 50 1736 51 1688 53 1640 54 1593 1543 1497

F04^^ 1634 54 1578 56 1525 58 1471 60 1416 62 1363 1311 1265

F05 2028 44 1994 45 1937 46 1899 47 1863 48 1814 1769 1724

TEMP RANGE

LOW

20-50

20-50

30-60

30 - 60

TEMP RANGE HIGH

25-55

25-55

40-70

35-65

Notes ^ DEFAULT SPEED ^^NOT RECOMMENDED FOR HEATING All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.

8 www.goodmanmfg.com SS-GC9C96 SS-GC9C96 www.goodmanmfg.com 9

Temperature Rise Range Chart

30 40

50 60

70 80

90 11

0 12

0 10

0 13

0 14

0 15

0

10 0

90 80 70 60 50 40 30 20 10

O U

TP U

T B

TU /H

R x

10 00

B TU

O U

TP U

T vs

TE M

P E

R AT

U R

E R

IS E

C H

A R

T TEMPERATURERISE

60 0

C FM

70 0

90 0 10

00 11 00 12

00

14 00

16 00 18

00 20 00 22

00 24 00

C FM

FO R

M U

LA S

B TU

O U

TP U

T =

C FM

x 1.

08 x

R IS

E

R IS

E =

B TU

O U

TP U

T 1.

08

C FM

80 0

Temperature Rise

O ut

pu t

BT U

/h x

1 ,0

00

Fo rm

ul as

BT U

/h O

ut pu

t = C

FM x

1 .0

8 x

Ri se

Ri se

=

BT U

/H O

ut pu

t

CF M

x 1

.0 8

B TU

O ut

pu t

Vs . T

em pe

ra tu

re R

is e

Ch ar

t

10 www.goodmanmfg.com SS-GC9C96 SS-GC9C96 www.goodmanmfg.com 11

Wiring Diagram GC9C96******AA

W iri

ng is

s ub

je ct

to c

ha ng

e. A

lw ay

s re

fe r

to t

he w

iri ng

d ia

gr am

o n

th e

un it

fo r t

he m

os t u

p- to

-d at

e w

iri ng

.

W

ar ni ng

Hi gh

V ol

ta ge

: Di

sc on

ne ct

a ll

po w

er b

ef or

e se

rv ic

in g

or i

ns ta

lli ng

t hi

s un

it. M

ul tip

le p

ow er

so

ur ce

s m ay

b e

pr es

en t.

Fa ilu

re to

d o

so m

ay c

au se

p ro

pe rt

y da

m ag

e, p

er so

na l i

nj ur

y, or

d ea

th .

GN

GND

RD

G N

24VAC

115 VAC

GND

G R

D

0140F02639-A

BK EAC

HUMIDIFIER

ID

NEUTRAL

WIRING TO UNIT

L

INTEG RATED CO

NTRO L M

O DULE

HOT SURFACE

GND

BLWR

NEUTRAL

WARNING:

GROUNDED.

OVERCURRENT PROTECTION DEVICE

MUST BE PROPERLY

SWITCH

NEUTRAL

ELECTRONIC

AIR

IGN

IND HI

DISCONNECT

FS

POLARIZED AND

NEUTRAL

LINE

NEUTRAL

JUNCTION BOX

BLWR IND LO

N

INDOOR

AIR CLEANER

HUM

DOOR

NEUTRAL

INTEG RATED CO

NTRO L M

O DULE

TO 115VAC/ 1 /60 HZ POWER SUPPLY WITH

115 VAC

HUM-OUT

IGNITER

CIRCULATOR

BEFORE SERVICING.

FLAME SENSOR

DISCONNECT POWER

LINE

BR

W H

G Y

YL

O R

PK

RD W

H PU

G Y

PK

WARNING:DISCONNECT

40 VA TR

ANSFO RM

ER

N NO

G

C

SWITCH PRESSURE LOW FIRE

SENSOR FLAME

1 ROLL OUT SWITCH SOME UNITS MAY HAVE

C TO UNIT MUST BE

PU

R D

AND GROUNDED.

1

JUNCTIO N

BO X

W H

3

BL

BR

W H

NO

LIMIT CONTROL AUTO RESET PRIMARY

WH

1

WH

L

GY

BK

SWITCH ASSEMBLY ID BLOWER TWO-STAGE PRESSURE

OR

SERVICING. WIRINGSWITCH PRESSURE HIGH FIRE

RD

L

N

BK

C

DOOR OPEN) (OPEN WHEN DOOR SWITCH COMPARTMENT BLOWER

GND

1

BLOWERCIRCULATOR

OR

/60 HZ

DISCONNECT

(WHITE RODGERS) GAS VALVE TWO STAGE

OVERCURRENT

CONNECTOR 2 CIRCUIT

WH

CHASSIS GROUND

2 3

IGNITER SURFACE

HOT

2

YL

PU

2

C

BLOWER DRAFT

INDUCED

LO

BK

BLOWER COMPARTMENT

115 VAC/ 1

BK

ECM MTR HARNESS

HI

O R

POWER BEFORE

RD

BK

TO

POWER SUPPLY WITH

BURNER COMPARTMENT

PROTECTION DEVICE

PROPERLY POLARIZED

NOTES: 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105v C. USE COPPER CONDUCTORS ONLY. 4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. 5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS)

COLOR CODES: PK PINK BR BROWN WH WHITE BL BLUE GY GRAY RD RED YL YELLOW OR ORANGE PU PURPLE GN GREEN BK BLACK

123

456

789

101112

READ CODES FROM LEFT TO RIGHT

EAC-H

XFM R-H

CIRC-H

LINE-H

E2 0

E3 9

E2E1

E15

E8E5

E4E3

E7

E6

E25

5

E26W14

HUM-H K8

1

LE FT

C EN

TE R

R IG

H T SW331313 SW1 R223

SW2

6 R226

RD

BL

RD

BR BR

BK

BK

BK

W H

W HW

H

W H

RD

PU

YL G

Y W

H

O R

G N

PU

PU

PU PU

NEUT2 NEUT1 CIRC-N EAC-N HUM

-N XFM

R-N

LINE-N

C

NO

NO

C

GND

MICRO TO

PS2 (9)

TR (7)

G

HI

C

TH (3)

24V TH ERM

O STAT CO

NNECTIO N

S N.E.C. CLASS 2 W IRE

VALVE GAS

W2

HLI (8) Y2

Y1

RLO (6)

O MVL (10)

NO

W1

C

R MANUAL RESET ROLLOUT LIMIT SWITCH

HIGH FIRE PRESS. SWITCH

C

LOW FIRE PRESS. SWITCH

MVC (11)DEHUM

PS1(5)

AUTO RESET PRIMARY LIMIT

24 VAC

NO

LO

MVH (4)

C

BLWR

AIR INDOOR

CIRCULATOR

R TO

MICRO TO

TO +VDC

INTEGRATED CONTROL MODULE

R D

GY

HLO (1)

INTEGRATED CONTROL MODULE

Internal Faults or IRQ Loss E E E Lockout Due to Excessive Retries Recycle E E 0 Low Stage Pressure Switch Stuck Closed E E 1 Low Stage pressure Switch Open E E 2 Open High Limit Switch E E 3 Flame Detected When no Flame Should be E E 4 Open Fuse E E 5 Low Flame Signal E E 6 Ignitor Relay Fault E E L High Stage Pressure Switch Stuck Closed E E 8 High Stage Pressure Switch Open E E 9 Reversed Line Polarity or Grounding Error E E A Internal Gas Valve Error E E b External Gas Valve Error E E C Open Rollout Switch E 1 1 ignitor Open E E N Inducer Relay Error E E j TWIN Error E E H GROUNDING ERROR E 1 0

Seven Segment DisplayStatus Seg# Seg# Seg#

5

21

4 3

RD BK

OR BL

YL

YL

BL OR

BK

RD T1

T2

T3

T4

T5 COMRD

GND

GND

SWITCH (PRESS.)

FIELD SPLICE FIELD GND

EQUIPMENT GND

INTERNAL TO

PROT. DEVICE

INTEGRATED CONTROL PLUG CONNECTION

SWITCH (TEMP.)

JUNCTION

LOW VOLTAGE (24V)

OVERCURRENT

TERMINAL

IGNITER

LOW VOLTAGE FIELD HI VOLTAGE (115V) HI VOLTAGE FIELD

PK

RD

YL PU

LIMIT CONTROL AUXILIARY AUTO RESET

TW IN

24 V

H U

M

E21

E24

RLI (12)

W/W1R Y/Y1G C Y2W2

TRANSFORMER 40 VA

AUTO RESET AUX LIMIT

10 www.goodmanmfg.com SS-GC9C96 SS-GC9C96 www.goodmanmfg.com 11

Accessories

Model Description GC9C96 0403BNA

GC9C96 0603BNA

GC9C96 0803BNA

GC9C96 1005CNA

72950 Concentric Vent Kit (2")

72951 Concentric Vent Kit (3")

CFSB17 Downflow Sub-Base 17.5"

CFSB21 Downflow Sub-Base 21"

RF000142 Drain Kit-Horizontal Left Vertical Flue

0170K00000S Flush Mount Vent Kit- 3" or 2"

0170K00001S Flush Mount Vent Kit- 2"

AFE18-60A Fossil Fuel (Dual Fuel) Kit

HASFK High-Altitude Natural Gas Kit HASFK-1 HASFK-1 HASFK-2 HASFK-2

HASFK High-Altitude LP Gas Kit TBD TBD TBD TBD

0270F05405 Horizontal Drain Tubing Kit

LPLP03 Low LP Gas Pressure Switch

LPM-08 LP Conversion Kits

Manualsnet FAQs

If you want to find out how the GC9C96 Goodman works, you can view and download the Goodman GC9C96 User's Manual on the Manualsnet website.

Yes, we have the User's Manual for Goodman GC9C96 as well as other Goodman manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Manual should include all the details that are needed to use a Goodman GC9C96. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Goodman GC9C96 User's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Goodman GC9C96 User's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Goodman GC9C96 User's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Goodman GC9C96 User's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Goodman GC9C96 User's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.