Tools Needed 5/16 nut driver Pliers Slotted screwdriver

Important Notes This unit must be properly grounded.

Read this instruction before installing the sub-base to the molded or metal sleeve. CAUTION The sub-base should be assembled to the

sleeve before securing the sleeve in the wall. CAUTION Electrical power must be disconnected

before installing the sub-base.

Electrical Requirements :

1. Electrical wiring may enter the sub-base through any of the knockout holes provided in the sub-base bottom or rear.

2. Refer to the unit nameplate for branch circuit requirements.

3. All wiring should be done in accordance with the local electrical codes and regulations.

4. Not approved for aluminum wire application.

5. If electrical wiring is placed in or against the sub- base enclosure, the sub-base must be grounded. Grounding holes have been provided in the back surface of the enclosure. See diagram. Green grounding screws and securing nuts are included.

Parts included in bag with Sub-Base

Installation Instructions for your new

RAK204U RAK204D15C RAK204D20C RAK204D30C RAK204E15C RAK204E20C RAK204E30C

Sub-Base

Before you begin - Read these instructions completely and carefully. IMPORTANT OBSERVE ALL GOVERNING CODES AND ORDINANCES. Note to Installer Be sure to leave these instructions with the Consumer. Note to Consumer Keep these instructions with your Owners Manual for future reference.

Type A 10 required

Type D 2 mounting clips for

metal sleeve

Chaseway and cover

Type E 2 mounting clips for

molded sleeve

4 nuts

Type B 2 required Type C

2 required

Kit Number Description

RAK204U NON-ELECTRICAL SUB-BASE

RAK204E15C 265 V 15 A

RAK204E20C 265 V 20 A

RAK204E30C 265 V 30 A

RAK204D15C 230/208 V 15 A

RAK204D20C 230/208 V 20 A

RAK204D30C 230/208 V 30 A

RAK4002D JUNCTION BOX

Type F 2 mounting clips for

snap together sleeves

2

Leveling screw Leveling screw

Top view Finished interior wall

Front view

Interior adjacent wall

Leveling screw

2

16

Side view

Interior wall

Finished oor

See note left side

OUTSIDE

Recommend 2 minimum clearance to interior adjacent wall both sides.

Chaseway knockout

3

3 min., adjustable to 5

2

132 min.

42 2

Installation Instructions INSTALL GROUND SCREW Install from the rear and secure from the inside of the sub-base using a nut. Secure branch circuit (or other) ground wire using a second nut.

INSTALL MOUNTING CLIP It is important to select the correct mounting clip for the type of wall sleeve being installed. Painted Steel: Use Type D Molded Polymer: Use Type E Snap Together: Use Type F

Molded sleeve (RAB77*)

Mounting clip for molded sleeve Type E

Metal Sleeve (RAB71*)

Mounting clip for metal sleeve Type D

Green ground screw Type C

Type A screws

Type C screwsAccess

PlatesType C screws

Type B screws

6 6

Type A screws

Side channels are adjustable from 13 to 2 in length by

of side channels. *all versions

NOTE: Remove knockouts from inside out. Knockouts (enclosure) 4 rear, 4 bottom. Use as required for branch circuit wire entrance.

3

Installation Instructions INSTALLATION FOR 230/208V MODELS Follow the installation instruction with the Power Supply Kit if RAK4002D Junction Box Kit to install junction box and connect to the unit wiring.

CONDUIT INSTALLATION FOR 265V UNITS (ALL MODELS) 1. Use the round hole at the bottom of the junction box

to attach conduit coming from the branch circuit. Attach the conduit using proper conduit connector and bring wires into the junction box. Leave 6 of wire free at the end of the conduit to allow connections to be made.

2. If a fuse and fuse holder are to be used, the knockout at the side of the box is for mounting a Buss Fuse holder. Be sure the fuse and fuse holder are of the same rating as the branch circuit. Leadwires at the fuse can be either soldered in place or attached using UL-listed 1/4 female (receptacle) crimp connectors.

CHASEWAY INSTALLATION FOR 265V MODELS WITH STEEL CONTROL BOX COVER. The chaseway can be used several ways in conjunction with the associated knockouts in the junction box and sub-base to protect and conceal wiring (cordsets/power supply kits and branch circuit wiring). 1. Wiring is placed between the two halves of the

chaseway. Observe the orientation of the chaseway.

Wiring

Chaseway cover

Chaseway

2. Align the screw holes and secure the halves together using two type A screws.

3. Remove the junction box cover by removing the 2 screws on the front and the 2 screws on the inside rear of the junction box. Retain for re-assembly. Slide the junction box to the right to clear the mounting slots on the front of the steel box.

4. Remove the rectangular knockout at the bottom of the junction box. Remove the rectangular knockout at the right end of the sub-base.

Junction box

Junction box cover

Knock out

Screws

Chaseway knockout

Front View

5. Slide the upper end of the chaseway with wiring protruding into rectangluar knockout opening in the junction box. Be sure chaseway ears are on the inside of the box. Drive one type A screw through the junction box bottom into the chaseway ear hole. Insert lower end of chaseway into rectangular hole in sub-base and slide to right into the rectangular knockout making sure chaseway side ears are inside the sub-base. Replace junction box on chassis in reverse order of Step 3. Route wire toward the center of the sub-base. Drive one type A screw through the sub-base slotted hole into chaseway ear hole.

6. Recheck to be sure the chaseway ears are inside the junction box and the sub-base and that no wiring is pinched.

7. Complete the connection of wiring inside the sub-base either by fully inserting the plug into the receptacle or attaching to the branch circuit wiring or

inside the sub-base. 8. Complete connections inside the junction box.

For additional information, refer to the installation Instructions in the Zoneline Owners Manual.

9. Replace and secure front covers on the sub-base and junction box. Do not pinch any wires.

Conduit

4

Installation Instructions CHASEWAY INSTALLATION FOR 265V MODELS WITH MOLDED SMC PLASTIC CONTROL BOX COVER The chaseway can be used several ways in conjunction with the associated knockouts in the junction box and sub-base to protect and conceal wiring (cordsets/power supply kits and branch circuit wiring). 1. Wiring is placed between the two halves of the

chaseway. Observe the orientation of the chaseway.

2. Align the lower screw holes and secure the halves together using one type A screw. The upper screw will be installed in Step 6.

3. Remove the junction box cover by removing the screw on the front. Rotate the cover to the right to unlock the locating tabs on the rear.

4. Remove the junction box from the molded SMC control box cover by removing the double helix screw from the top. Save for re-assembly. Carefully lift the junction box upward to clear the locating slots on the molded control box cover. DO NOT REMOVE THE GROUND WIRE FROM THE CHASSIS OR JUNCTION BOX.

5. Remove the rectangular knockout at the bottom of the junction box. Remove the rectangular knockout at the right end of the sub-base.

Screw Tab

Junction Box Base

Rectangular knockout

Chaseway knockout

Front View

6. Slide the upper end of the chaseway with wiring protruding into rectangular knockout opening in the junction box. Be sure chaseway ears are on the inside of the box. Drive one Type A screw through the junction box bottom into the chaseway ear hole. Drive one Type A screw into the upper hole in the chaseway. Insert the lower end of the chaseway into the rectangular hole in the sub-base and slide to the right into the rectangular knockout making sure chaseway side ears are inside the sib-base. Replace junction box on chassis in reverse order of Step 4. Drive one Type A screw through the sub- base slotted hole into chaseway ear hole.

7. Recheck to be sure the chaseway ears are inside the junction box and the sub-base and that no wiring is pinched.

8. Complete the connection of wiring inside the sub- base either by fully inserting the plug into the receptacle or attaching to the branch circuit wiring

wiring inside the sub-base. 9. Complete connections inside the junction box.

For additional information, refer to the Installation Instructions in the Zoneline Owners Manual.

10. Replace and secure all front covers. Do not pinch any wires.

Wiring

Chaseway cover

Chaseway

A Quality Product of GE Appliances

31-5000401 Rev. 1 10-20 GEA

Outil ncessaire Tournevis douille 5/16 po Pince Tournevis pour crou fente

Remarques importantes Cet appareil doit tre correctement mis la terre.

Lisez ces instructions avant dinstaller le socle sur le manchon moul ou mtallique.

ATTENTION Le socle doit tre assembl au manchon avant de fixer le manchon au mur.

ATTENTION Lalimentation lectrique doit tre dbranche avant dinstaller le socle.

EXIGENCES LECTRIQUES :

1. Le cblage lectrique doit pntrer dans le socle travers une des dbouchures prsentes dans le bas ou larrire du socle.

2. Reportez-vous la plaque signaltique de lappareil pour les exigences relatives au circuit de drivation.

3. Tout le cblage lectrique doit tre ralis conformment aux codes et rglements locaux.

4. Le cblage en aluminium nest pas approuv.

5. Si le cblage est plac dans ou contre lenveloppe du socle, le socle doit tre mis la terre. Les trous de mise la terre sont situs sur la face arrire de lenveloppe.

Voir lillustration. Des vis de mise la terre vertes et des crous de fixation sont inclus.

Pices incluses dans le sac avec le socle

Instructions dinstallation pour votre nouveau socle

RAK204U RAK204D15C RAK204D20C RAK204D30C RAK204E15C RAK204E20C RAK204E30C

Avant de commencer Lisez ces instructions attentivement et en totalit. IMPORTANT OBSERVEZ TOUS LES CODES ET RGLEMENTS EN VIGUEUR. Remarque linstallateur Assurez-vous de remettre ces instructions au consommateur. Remarque au consommateur Conservez ces instructions avec le manuel dutilisation pour consultation ultrieure.

Type A 10 requis

Attaches de montage de type D2 pour man-

chon mtallique

Chemin de cble et couvercle

Attaches de montage de type E2 pour man-

chon moul

4 crous

Type B 2 requis Type C

2 requis

Numro de trousse Description

RAK204U SOCLE NON LECTRIQUE

RAK204E15C 265 V 15 A

RAK204E20C 265 V 20 A

RAK204E30C 265 V 30 A

RAK204D15C 230/208 V 15 A

RAK204D20C 230/208 V 20 A

RAK204D30C 230/208 V 30 A

RAK4002D BOTE DE JONCTION

4 crous

Attaches de montage de type F2 pour les botiers embotables

2

Vis de nivellement Vis de nivellement

Vue de dessus

Mur intrieur fini

Vue de face

Mur intrieur adjacent

Vis de nivellement

2

16

Vue latrale

Mur intrieur

Plancher fini

Voir la note gauche

EXTRIEUR

Vis de terre verte (type C)

Vis de type A

Vis de type C

Vis de type A

Plaques daccs

Vis de type B

Vis de type C

Dbouchure pour chemin de cble

3

3 min., ajustable 5

2

13 2 min.

42 2

6 6

*Toutes les versions

Les profils latraux sont ajustables de 13 2 po en longueur en cassant les sections des profils.

REMARQUE : Retirez les dbouchures depuis lintrieur vers lextrieur. Dbouchures : 4 larrire, 4 dans le bas. Utilisez-les selon ce qui est requis pour lentre du cble du circuit de drivation.

Dgagement minimal recommand de 2 po au mur intrieur adjacent des deux cts.

POSER LA VIS DE TERRE Posez-la depuis larrire et

socle laide dun crou. Fixez

circuit de drivation (ou autre) laide dun autre crou.

INSTALLER UNE ATTACHE DE MONTAGE Il est important de choisir la bonne attache de montage pour le type de manchon mural qui est install. Acier peint : Utilisez le type D Polymre moul : Utilisez le type E Embotable : Utilisez le type F

Manchon moul (RAB77*)

Attache de montage pour manchon moul de type E

Manchon mtallique (RAB71*)

Attache de montage pour manchon mtallique de type D

3

Instructions dinstallation INSTALLATION des modles 230/208 V : Suivez les instructions dinstallation de la trousse dalimenta- tion lectrique ou de la bote de jonction RAK4002D pour in- staller la bote de jonction et connecter le cblage de lappareil.

INSTALLATION DU CONDUIT POUR AP- PAREILS 265 V (TOUS LES MODLES) 1. Utilisez le trou rond dans le bas de la bote de jonction pour

le conduit laide du connecteur de conduit appropri et acheminer les cbles dans la bote de jonction. Laissez un segment de 6 po libre lextrmit du conduit pour les con- nexions.

2. Si un fusible ou un porte-fusible sera utilis, la dbouchure sur le ct de la bote sert monter un porte-fusible Buss. Assurez-vous que le fusible et le porte-fusible sont du mme

- eurs sertir femelles (prises) de 1/4 po homologus UL.

INSTALLATION DU CHEMIN DE CBLE POUR MODLES 265 V AVEC COUVERCLE DE BOTE DE COMMANDE EN ACIER.

conjointement avec les dbouchures associes dans la bote

(trousses de cordon amovible/dalimentation lectrique et cblage de circuit de drivation). 1. Le cblage est plac entre les deux moitis du chemin de

cble. Observez lorientation du chemin de cble.

Cblage

Couvercle de chemin de cble

Chemin de cble

avec deux vis de type A. 3. Enlevez le couvercle de la bote de jonction en retirant les

2 vis sur le devant et les 2 vis sur larrire intrieur de la bote de jonction. Conservez pour rassemblage. Glissez la bote de jonction vers la droite pour dgager les fentes de montage sur le devant de la bote de commande en acier.

4. Enlevez la dbouchure rectangulaire dans le bas de la bote de jonction. Enlevez la dbouchure rectangulaire lextrmit droite du socle.

Junction box

Junction box cover

Knock out

Screws

Chaseway knockout

Front View

qui dpassent) dans la dbouchure rectangulaire de la bote de jonction. Assurez-vous que les oreilles du chemin de cble se situent lintrieur de la bote. Posez une vis de type A travers le bas de la bote de jonction et dans le trou doreille du chemin de cble. Insrez lextrmit infrieure du chemin de cble dans le trou rectangulaire du socle et glissez vers la droite dans la dbouchure rectangulaire en vous assurant que les oreilles latrales se situent lintrieur du socle. Replacez la bote de jonction sur le chssis dans lordre inverse de ltape 3. Acheminez le cble vers le centre du socle. Posez une vis de type A travers le trou oblong du socle et dans le trou doreille du chemin de cble.

du chemin de cble se trouvent lintrieur de la bote de jonction et du socle, et quaucun cble nest pinc.

7. Compltez la connexion du cblage lintrieur du socle en

le cblage du circuit de drivation ou dautres dispositifs installs sur le site. Enroulez le cblage excdentaire lintrieur du socle.

8. Terminez les connexions lintrieur de la bote de jonction. Pour des renseignements supplmentaires, reportez-vous aux instructions dinstallation du manuel dutilisation du Zoneline.

Conduit

Couvercle de la bote de jonction

bote de jonction

Vis

Dbouchure

Vue de face

Dbouchure pour chemin de cble

4

Instructions dinstallation INSTALLATION DU CHEMIN DE CBLE POUR MODLES 265 V AVEC COU- VERCLE DE BOTE DE COMMANDE EN ACIER.

conjointement avec les dbouchures associes dans la bote

(trousses de cordon amovible/dalimentation lectrique et cblage de circuit de drivation). 1. Le cblage est plac entre les deux moitis du chemin de

cble. Observez lorientation du chemin de cble.

Cblage

Couvercle de chemin de cble

Chemin de cble

ensemble avec une vis de type A. La vis suprieure sera pose ltape 6.

3. Enlevez le couvercle de la bote de jonction en retirant la vis sur le devant. Faites pivoter le couvercle vers la droite pour dverrouiller les languettes de reprage larrire.

4. Retirez la bote de jonction du couvercle de la bote de commande SMC moule en retirant la vis double hlice du dessus. Conservez pour rassemblage. Soulevez avec soin

sur le couvercle de la bote de commande moule. NENLEVEZ PAS LE FIL DE TERRE DU CHSSIS OU DE LA BOTE DE JONCTION.

5. Enlevez la dbouchure rectangulaire dans le bas de la bote de jonction. Enlevez la dbouchure rectangulaire lextrmit droite du socle.

Screw Tab

Junction Box Base

Rectangular knockout

Chaseway knockout

Front View

6. Glissez lextrmit suprieure du chemin de cble

rectangulaire de la bote de jonction. Assurez-vous que les oreilles du chemin de cble se situent lintrieur de la bote. Posez une vis de type A travers le bas de la bote de jonction et dans le trou doreille du chemin de cble. Posez une vis de type A dans le trou suprieur du chemin de cble. Insrez lextrmit infrieure du chemin de cble dans le trou rectangulaire du socle et glissez vers la droite dans la dbouchure rectangulaire en vous assurant que les oreilles latrales se situent lintrieur du socle. Acheminez le cble vers le centre du socle. Replacez la bote de jonction sur le chssis dans lordre inverse de ltape 4. Posez une vis de type A travers le trou oblong du socle et dans le trou doreille du chemin de cble.

oreilles du chemin de cble se trouvent lintrieur de la bote de jonction et du socle, et quaucun cble nest pinc.

8. Compltez la connexion du cblage lintrieur du

ou en attachant le cblage du circuit de drivation ou dautres dispositifs installs sur le site. Enroulez le cblage excdentaire lintrieur du socle.

9. Terminez les connexions lintrieur de la bote de jonction. Pour des renseignements supplmentaires, reportez-vous aux instructions dinstallation du manuel dutilisation du Zoneline.Languette

de vis

Base de la bote de jonction

Dbouchure rectangulaire

Dbouchure pour chemin de cble

Vue de face

Un produit de qualit GE Appliances

Manualsnet FAQs

If you want to find out how the RAK204U GE works, you can view and download the GE RAK204U Sub-Base Installation Instructions on the Manualsnet website.

Yes, we have the Installation Instructions for GE RAK204U as well as other GE manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Installation Instructions should include all the details that are needed to use a GE RAK204U. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the GE RAK204U Sub-Base Installation Instructions is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This GE RAK204U Sub-Base Installation Instructions consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download GE RAK204U Sub-Base Installation Instructions free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print GE RAK204U Sub-Base Installation Instructions, simply download the document to your computer. Once downloaded, open the PDF file and print the GE RAK204U Sub-Base Installation Instructions as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.