GE RAVTRANS4 Plenum Installation Instructions PDF




Summary of Content for GE RAVTRANS4 Plenum Installation Instructions PDF
31-5000570 Rev. 0 11-20 GEA
RAVTRANS4 will fit an existing GE Appliance RAVTWPT14 plenum kit.
Installation Instructions for your new RAVTRANS4 Transition Plenum For replacing AZ90, AZ91 series units with an 8 - 14 outside wall depth
Before you begin - Read these instructions completely and carefully. IMPORTANT OBSERVE ALL GOVERNING CODES AND ORDINANCES. Note to Installer Be sure to leave these instructions with the Consumer. Note to Consumer Keep these instructions with your Owners Manual for future reference.
RAVTRANS4 kit is required when replacing an AZ90/AZ91 series vertical air conditioner with a new AZ95 series vertical air conditioner that is installed in an RAVWPT14 wall plenum. The RAVWPT14 is the black telescopic sheet metal plenum that was used for AZ90/AZ91 installations with exterior walls greater than 8 inches thick. Differences in chassis designs between the AZ90/AZ91 series and AZ95 series require careful installation planning. Changes in drain exit locations and drain routing, electrical connections, platform height, and conditioned air duct locations are all items that need to be considered when replacing an AZ90/ AZ91 series unit with an AZ95 series unit.
Parts Included Transition Plenum with Air Divider 10 - #10 long 5/16 hex head sheet metal screws Front Bracket
Installation Overview
GE is a trademark of the General Electric Company. Manufactured under trademark license.
Plenum
Air Divider
Front Bracket
Unit*
Included in RAVTRANS4
RAVDPLAT*
Existing Wall Plenum RAVWPT14 Inside*
Exterior/ Outside Wall
Existing Wall Plenum RAVWPT14 Outside*
Existing Architectural Louver*
*Sold Separately
2
Installation Instructions STEP 1: Prepare Installation Area by Removing AZ90/AZ91 Unit and Existing RAVWPT14 Inside Wall Plenum WARNING
the service panel and lock the area to prevent power from being switched on accidentally. To remove the AZ90/AZ91 series unit: 1. Disconnect the power coming into the unit from the main breaker
or closet mounted disconnect. 2. Remove power disconnect on front of the unit. 3. Remove front panel. 4. Disconnect power wires from the unit. 5. Disconnect thermostat wires from the unit. 6. Disconnect all of the drains. 7. Disconnect air duct on top of the unit. 8. Remove the unit. 9. Remove the platform. 10. Remove the RAVWPT14 inside wall plenum. Do not remove
the outside half of the RAVWPT14 or existing exterior grille.
STEP 2: Install and Connect the Transition Plenum to the Existing Wall Plenum
the interior side of the wall.
4. Caulk inside the plenum along seam between the inner and outer plenums. Caulk the bottom and up each side at least 3.
5. Caulk any gaps between the plenum and the wall on the sides and bottom.
plenum.
Rigid Ductwork
Inside Wall
Access Panel or Closet Door
Existing RAVWPT14 Inside Wall Plenum Removed
Existing RAVWPT14
Outside Wall
Plenum
Existing Exterior Grille
Caulking
Existing RAVWPT14 Outside Wall Plenum
Existing Exterior Grille
Caulking
CaulkingExisting Exterior Grille
Existing RAVWPT14 Outside
Exterior Wall
RAVTRANS4
Align RAVTRANS4 with Existing Plenum
RAVTRANS4
3
Installation Instructions
STEP 4: Attach the Front Bracket to the Plenum 1. Align the front bracket with the plenum. 2. Fasten the front bracket to the plenum with the 6 screws provided.
STEP 3: Adjust the Divider (if required) 1. Remove the front 2 screws and loosen the rear 2 screws. 2. Slide the divider toward the grille until it is sealed against the grille. 3. Tighten the 2 rear screws.
Rear Screws
Front Screws
Tighten rear screws
Divider moved into position against the exterior grille
4
Notes
Printed in the United States
Instructions dinstallation pour le nouveau
RAVTRANS4 Plnum de transition Pour remplacer les units des sries AZ90 et AZ91 avec une profondeur de mur extrieur de 8 14 po
Avant de commencer - Veuillez lire ces instructions attentivement et en totalit. IMPORTANT OBSERVEZ TOUS LES CODES ET RGLEMENTS EN VIGUEUR. Note linstallateur Assurez-vous de laisser ces instructions au consommateur. Note au consommateur - Conservez ces instructions avec votre manuel dutilisation pour consultation ultrieure.
31-5000570 Rev. 0 11-20 GEA
Le plnum RAVTRANS4 est compatible avec la trousse de plnum RAVTWPT14 de GE Appliances.
La trousse RAVTRANS4 est ncessaire pour remplacer un climatiseur vertical existant de srie AZ90/AZ91 par un nouveau climatiseur vertical de srie AZ95 qui est install dans un plnum mural RAVWPT14. Le modle RAVWPT14 est un plnum tlescopique en tle noire qui est utilis pour les installations dunits AZ90/AZ91 avec murs extrieurs suprieurs 8 pouces dpaisseur. Des diffrences dans le dessin des chssis entre les sries AZ90/AZ91 et la srie AZ95 exigent une planification minutieuse de linstallation. Le remplacement dune unit de srie AZ90/AZ91 par une unit de srie AZ95 exige de considrer les modifications suivantes : trajectoire du tuyau dvacuation, position de la sortie dvacuation, connexions lectriques, hauteur de la plateforme et emplacement des conduits dair climatis.
GE est une marque de commerce de General Electric Company. Fabriqu sous licence de marque.
Pices incluses Plnum de transition avec sparateur dair Vis tle 10 - #10 de 3/4 po de long et tte
hexagonale 5/16 po Support frontal
Aperu de linstallation
Plnum
Sparateur dair
Support frontal
Unit*
Inclus avec RAVTRANS4
RAVDPLAT*
Plnum mural RAVWPT14 (intrieur)*
Mur extrieur
Plnum mural existant RAVWPT14 (extrieur)*
vent lames architectural existant*
*Vendus sparment
2
Instructions dinstallation TAPE 1: Prparer la zone dinstallation en retirant lunit AZ90/AZ91 et le plnum mural intrieur RAVWPT14 existant WARNING
Risque de choc lectrique pouvant causer une blessure ou la mort. Avant de procder une
rtablissement accidentel du courant. Pour retirer lunit de srie AZ90/AZ91 : 1. Coupez le courant qui arrive dans lunit depuis le disjoncteur
principal ou linterrupteur mont dans larmoire. 2. Retirez linterrupteur de courant sur le devant de lunit. 3. Retirez le panneau frontal. 4. Dconnectez les cbles dalimentation lectrique de lunit.
6. Dconnectez tous les tuyaux dvacuation. 7. Dconnectez le conduit dair dans le haut de lunit. 8. Retirez lunit. 9. Retirez la plateforme. 10. Retirez le plnum mural intrieur RAVWPT14. Ne retirez
pas la moiti extrieure du plnum RAVWPT14 ni la grille extrieure existante.
TAPE 2: Installer et connecter le plnum de transition sur le plnum mural existant REMARQUE : Le RAVTRANS4 rentre lintrieur du plnum extrieur RAVWPT14. 1. Insrez le plnum RAVTRANS4 dans le plnum existant et assurez-vous que le plnum sera compltement insr.
Le collet mural doit toucher le ct intrieur du mur. 2. Tirez le plnum RAVTRANS4 vers lextrieur sur 1 2 po et appliquez du calfeutrage sur le ct extrieur du collet
mural sur les cts suprieur, infrieur et latraux. 3. Insrez compltement le plnum RAVTRANS4 jusqu ce que le collet mural sappuie contre le ct intrieur du mur
en comprimant le calfeutrage. 4. Calfeutrez lintrieur du plnum le long du joint entre les plnums intrieur et extrieur. Calfeutrez le bas et le haut
de chaque ct sur au moins 3 po. 5. Calfeutrez toute interstice entre le plnum et le mur sur les cts et le bas. 6. Fixez le plnum intrieur sur le plnum extrieur laide de vis achetes localement. Ne posez pas de vis dans le
bas du plnum.
Conduit rigide
Mur intrieur
Panneau daccs ou porte darmoire
Plnum mural intrieur RAVWPT14 existant retir
Plnum mural
extrieur RAVWPT14
existant
Grille extrieure existante
Une fois termin, la zone de larmoire devrait ressembler ceci.
RAVTRANS4
Calfeutrage
Plnum mural extrieur RAVWPT14 existant
Grille extrieure existante
Calfeutrage
Grille extrieure existante
RAVWPT14 existant
Mur extrieur
RAVTRANS3
Aligner RAVTRANS4 sur le plnum existant
3
Instructions dinstallation
TAPE 4: Fixer le support frontal sur le plnum 1. Alignez le support frontal sur le plnum. 2. Fixez le support frontal sur le plnum laide des 6 vis fournies.
TAPE 3: Ajuster le sparateur (si ncessaire) 1. Retirez les 2 vis avant et desserrez les 2 vis arrire. 2. Glissez le sparateur vers la grille jusqu ce quil sappuie sur celle-ci dune faon tanche. 3. Serrez les 2 vis arrire.
Vis arrire
Vis avant
Serrer les vis arrire
Sparateur gliss en position contre la grille extrieure
4
Notes
Instrucciones de Instalacin para su nuevo RAVTRANS4 Plnum de Transicin Para reemplazar las unidades de las series AZ90, AZ91 con una profundidad de pared exterior de entre 8 y 14
Antes de comenzar lea estas instrucciones completamente y de forma detenida. IMPORTANTE- CUMPLA CON TODOS LOS CDIGOS Y ORDENANZAS GUBERNAMENTALES. Nota para el Instalador Asegrese de entregar estas instrucciones al Consumidor. Nota para el Consumidor Guarde estas instrucciones con su Manual del Propietario para referencia futura.
31-5000570 Rev. 0 11-20 GEA
El RAVTRANS4 se ajustar al kit de plnum RAVTWPT8 de GE Appliances existente.
El kit RAVTRANS4 es necesario al reemplazar un acondicionador de aire vertical de las series AZ90/AZ91 por un acondicionador de aire vertical nuevo de la serie AZ95 instalado en un plnum de pared RAVWPT14. El RAVWPT14 es un plnum telescpico negro de chapa metlica usado en instalaciones de AZ90/AZ91 con paredes exteriores de un grosor superior a 8 pulgadas. Las diferencias en los diseos de chasis entre las series AZ90/AZ91 y AZ95 requieren de una planificacin detallada de su instalacin. Los cambios en las ubicaciones de las salidas del drenaje y sus recorridos, las conexiones elctricas, la altura de la plataforma, y el conducto del acondicionador de aire son todos temas que se debern tener en cuenta al reemplazar una unidad de la serie AZ91/AZ91 por una unidad de la serie AZ95.
GE Appliances es una marca de General Electric Company. Fabricado bajo licencia de la marca.
Piezas Incluidas Plnum de Transicin con Divisor de Aire 10 tornillos metlicos n 10 y longitud de para
chapa con cabeza hexagonal de 5/16 Soporte Frontal
Plnum
Divisor de Aire
Soporte Frontal
Informacin General de la Instalacin
Unidad*
Incluido en RAVTRANS4
RAVDPLAT*
Interior del Plnum de Pared RAVWPT14 Existente*
Exterior/ Pared Externa
Exterior del Plnum de Pared Existente RAVWPT14*
Persiana Arquitectnica Existente*
*Se Adquiere por Separado
2
Instrucciones de Instalacin PASO 1: Prepare el rea de Instalacin Retirando la Unidad AZ90/AZ91 y el Plnum de Pared Interior RAVWPT14 Existente WARNING Existe riesgo de descargas elctricas que pueden ocasionar lesiones o la muerte. Antes de
active de forma accidental. Para retirar la unidad de las series AZ90/AZ91: 1. Desconecte la corriente que ingresa a la unidad desde el panel
del disyuntor principal o desde la desconexin montada en el armario.
2. Retire la desconexin de corriente del frente de la unidad. 3. Retire el panel frontal. 4. Desconecte los cables de corriente de la unidad. 5. Desconecte los cables del termostato de la unidad. 6. Desconecte todo el drenaje. 7. Desconecte el conducto de aire que se encuentra sobre la
unidad. 8. Retire la unidad. 9. Retire la plataforma. 10. Retire el plnum de pared interior RAVWPT14. No retire la
mitad exterior del RAVWPT14 o la rejilla exterior existente.
PASO 2: Instale y Conecte el Plnum de Transicin al Plnum de Pared Existente NOTA: El RAVTRANS4 se ajustar dentro del plnum exterior RAVWPT14 existente. 1. Inserte el RAVTRANS4 en el plnum existente y asegrese de que quede completamente instalado las bridas de
pared debern tener contacto con el lado interior de la pared. 2. Coloque el RAVTRANS4 1 o 2 hacia afuera y aplique sellador sobre el lado exterior de la brida de pared en sus
partes superior, inferior y laterales. 3. Inserte completamente el RAVTRANS4 hasta que las bridas de pared estn niveladas contra el lado interior en su
totalidad, comprimiendo el sellador. 4. Selle la parte interior del plnum a lo largo de la unidad, entre los plnums interior y exterior. Selle por lo menos 3
en la parte inferior y superior a cada lado. 5. Selle cualquier brecha entre el plnum y la pared tanto en los laterales como en la parte inferior. 6. Asegure el plnum interior al plnum exterior usando los tornillos suministrados. No coloque los tornillos en la parte
inferior del plnum.
Conducto Rgido
Pared Interior
Panel de Acceso o Puerta del Armario
Retiro del Plnum de Pared Interior RAVWPT14 Existente
Plnum de Pared
Exterior RAVWPT14
Existente
Rejilla Exterior Existente
Una vez completado, el rea del armario deber verse as.
Sellado
Plnum de Pared Exterior RAVWPT14 Existente
Rejilla Exterior Existente
Sellado
Sellado Rejilla Exterior Existente
RAVWPT14 Exterior Existente
Pared Exterior
RAVTRANS4
Alinee el RAVTRANS4 con el Plnum Existente
RAVTRANS4
3
Instrucciones de Instalacin
PASO 4: Adhiera el Soporte Frontal al Plnum 1. Alinee el soporte frontal con el plnum. 2. Ajuste el soporte frontal al plnum con los 6 tornillos provistos.
PASO 3: Ajuste el Divisor (si corresponde)
2. Deslice el divisor hacia la rejilla hasta que quede sellada contra la rejilla. 3. Ajuste los 2 tornillos traseros. Tornillos
Traseros
Tornillos Frontales </
Related manuals for GE RAVTRANS4 Plenum Installation Instructions















Manualsnet FAQs
If you want to find out how the RAVTRANS4 GE works, you can view and download the GE RAVTRANS4 Plenum Installation Instructions on the Manualsnet website.
Yes, we have the Installation Instructions for GE RAVTRANS4 as well as other GE manuals. All you need to do is to use our search bar and find the user manual that you are looking for.
The Installation Instructions should include all the details that are needed to use a GE RAVTRANS4. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.
The best way to navigate the GE RAVTRANS4 Plenum Installation Instructions is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.
This GE RAVTRANS4 Plenum Installation Instructions consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.
You can download GE RAVTRANS4 Plenum Installation Instructions free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.
To be able to print GE RAVTRANS4 Plenum Installation Instructions, simply download the document to your computer. Once downloaded, open the PDF file and print the GE RAVTRANS4 Plenum Installation Instructions as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.