GE RAVTRANS3 Plenum Installation Instructions PDF

1 of 12
1 of 12

Summary of Content for GE RAVTRANS3 Plenum Installation Instructions PDF

31-5000569 Rev. 0 11-20 GEA

RAVTRANS3 will fit an existing GE Appliance RAVTWPT8 plenum kit.

Installation Instructions for your new RAVTRANS3 Transition Plenum For replacing AZ90, AZ91 series units with a 5.5 - 8 outside wall depth

Before you begin - Read these instructions completely and carefully. IMPORTANT OBSERVE ALL GOVERNING CODES AND ORDINANCES. Note to Installer Be sure to leave these instructions with the Consumer. Note to Consumer Keep these instructions with your Owners Manual for future reference.

RAVTRANS3 kit is required when replacing an AZ90/AZ91 series vertical air conditioner with a new AZ95 series vertical air conditioner that is installed in an RAVWPT8 wall plenum. The RAVWPT8 is the black telescopic sheet metal plenum that was used for AZ90/AZ91 installations with exterior walls less than 8 inches thick. Differences in chassis designs between the AZ90/AZ91 series and AZ95 series require careful installation and planning. Changes in drain exit locations and drain routing, electrical connections, platform height, and conditioned air duct locations are all items that need to be considered when replacing an AZ90/ AZ91 series unit with an AZ95 series unit.

Parts Included Transition Plenum with Air Divider 10 - #10 long 5/16 hex head sheet metal screws Front Bracket

Installation Overview

GE is a trademark of the General Electric Company. Manufactured under trademark license.

Plenum

Air Divider

Front Bracket

Unit*

Included in RAVTRANS3

RAVDPLAT*

RAVTRANS3

Existing Wall Plenum RAVWPT8 Inside*

Exterior/ Outside Wall

Existing Wall Plenum RAVWPT8 Outside*

Existing Architectural Louver*

*Sold Separately

2

Installation Instructions STEP 1: Prepare Installation Area by Removing AZ90/AZ91 Unit and Existing RAVWPT8 Inside Wall Plenum WARNING

the service panel and lock the area to prevent power from being switched on accidentally. To remove the AZ90/AZ91 series unit: 1. Disconnect the power coming into the unit from the main breaker

or closet mounted disconnect. 2. Remove power disconnect on front of the unit. 3. Remove front panel. 4. Disconnect power wires from the unit. 5. Disconnect thermostat wires from the unit. 6. Disconnect all of the drains. 7. Disconnect air duct on top of the unit. 8. Remove the unit. 9. Remove the platform. 10. Remove the RAVWPT8 inside wall plenum. Do not remove the

outside half of the RAVWPT8 or existing exterior grille.

STEP 2: Install and Connect the Transition Plenum to the Existing Wall Plenum

the interior side of the wall.

4. Caulk inside the plenum along seam between the inner and outer plenums. Caulk the bottom and up each side at least 3.

5. Caulk any gaps between the plenum and the wall on the sides and bottom.

plenum.

Rigid Ductwork

Inside Wall

Access Panel or Closet Door

Existing RAVWPT8 Inside Wall Plenum Removed

Existing RAVWPT8

Outside Wall

Plenum

Existing Exterior Grille

Caulking

Existing RAVWPT8 Outside Wall Plenum

Existing Exterior Grille

Caulking

CaulkingExisting Exterior Grille

Existing RAVWPT8 Outside

Exterior Wall

RAVTRANS3

Align RAVTRANS3 with Existing Plenum

3

Installation Instructions

STEP 4: Attach the Front Bracket to the Plenum 1. Align the front bracket with the plenum. 2. Fasten the front bracket to the plenum with the 6 screws provided.

STEP 3: Adjust the Divider (if required) 1. Remove the front 2 screws and loosen the rear 2 screws. 2. Slide the divider toward the grille until it is sealed against the grille. 3. Tighten the 2 rear screws.

Rear Screws

Front Screws

Tighten rear screws

Divider moved into position against the exterior grille

4

Notes

Printed in the United States

Instructions dinstallation pour le nouveau

RAVTRANS3 Plnum de transition Pour remplacer les units des sries AZ90 et AZ91 avec une profondeur de mur extrieur de 5,5 8 po

Avant de commencer - Veuillez lire ces instructions attentivement et en totalit. IMPORTANT OBSERVEZ TOUS LES CODES ET RGLEMENTS EN VIGUEUR. Note linstallateur Assurez-vous de laisser ces instructions au consommateur. Note au consommateur - Conservez ces instructions avec votre manuel dutilisation pour consultation ultrieure.

31-5000569 Rev. 0 11-20 GEA

Le plnum RAVTRANS3 est compatible avec la trousse de plnum RAVTWPT8 de GE Appliances.

La trousse RAVTRANS3 est ncessaire pour remplacer un climatiseur vertical existant de srie AZ90/AZ91 par un nouveau climatiseur vertical de srie AZ95 qui est install dans un plnum mural RAVWPT8. Le modle RAVWPT8 est un plnum tlescopique en tle noire qui est utilis pour les installations dunits AZ90/AZ91 avec murs extrieurs de moins de 8 pouces dpaisseur. Des diffrences dans le dessin des chssis entre les sries AZ90/AZ91 et la srie AZ95 exigent une planification minutieuse de linstallation. Le remplacement dune unit de srie AZ90/AZ91 par une unit de srie AZ95 exige de considrer les modifications suivantes : trajectoire du tuyau dvacuation, position de la sortie dvacuation, connexions lectriques, hauteur de la plateforme et emplacement des conduits dair climatis.

GE est une marque de commerce de General Electric Company. Fabriqu sous licence de marque.

Pices incluses Plnum de transition avec sparateur dair Vis tle 10 - #10 de 3/4 po de long et tte

hexagonale 5/16 po Support frontal

Aperu de linstallation

Plnum

Sparateur dair

Support frontal

Unit*

Inclus avec RAVTRANS3

RAVDPLAT*

RAVTRANS3

Plnum mural existant RAVWPT8 (intrieur)*

Mur extrieur

Plnum mural existant RAVWPT8 (extrieur)*

vent lames architectural existant*

*Vendus sparment

2

Instructions dinstallation TAPE 1: Prparer la zone dinstallation en retirant lunit AZ90/AZ91 et le plnum mural intrieur RAVWPT8 existant WARNING Risque de choc lectrique pouvant causer une blessure ou la mort. Avant de procder une

rtablissement accidentel du courant. Pour retirer une unit de srie AZ90/AZ91 : 1. Coupez le courant qui arrive dans lunit depuis le disjoncteur

principal ou linterrupteur mont dans larmoire. 2. Retirez linterrupteur de courant sur le devant de lunit. 3. Retirez le panneau frontal. 4. Dconnectez les cbles dalimentation lectrique de lunit.

6. Dconnectez tous les tuyaux dvacuation. 7. Dconnectez le conduit dair dans le haut de lunit. 8. Retirez lunit. 9. Retirez la plateforme. 10. Retirez le plnum mural intrieur RAVWPT8. Ne retirez pas la

moiti extrieure du plnum RAVWPT8 ni la grille extrieure existante.

TAPE 2: Installer et connecter le plnum de transition sur le plnum mural existant REMARQUE : Le RAVTRANS3 rentre lintrieur du plnum extrieur RAVWPT8. 1. Insrez le plnum RAVTRANS3 dans le plnum existant et assurez-vous que le plnum sera compltement insr.

Le collet mural doit toucher le ct intrieur du mur. 2. Tirez le plnum RAVTRANS3 vers lextrieur sur 1 2 po et appliquez du calfeutrage sur le ct extrieur du collet

mural sur les cts suprieur, infrieur et latraux. 3. Insrez compltement le plnum RAVTRANS3 jusqu ce que le collet mural sappuie contre le ct intrieur du mur

en comprimant le calfeutrage. 4. Calfeutrez lintrieur du plnum le long du joint entre les plnums intrieur et extrieur. Calfeutrez le bas et le haut

de chaque ct sur au moins 3 po. 5. Calfeutrez toute interstice entre le plnum et le mur sur les cts et le bas. 6. Fixez le plnum intrieur sur le plnum extrieur laide de vis achetes localement. Ne posez pas de vis dans le

bas du plnum.

Conduit rigide

Mur intrieur

Panneau daccs ou porte darmoire

Plnum mural intrieur RAVWPT8 existant retir

Plnum mural

extrieur RAVWPT8

existant

Grille extrieure existante

Une fois termin, la zone de larmoire devrait ressembler ceci

Calfeutrage

Plnum mural extrieur RAVWPT8 existant

Grille extrieure existante

Calfeutrage

CalfeutrageGrille extrieure existante

RAVWPT8 existant

Mur extrieur

RAVTRANS3

Aligner RAVTRANS3 sur le plnum existant

3

Instructions dinstallation

TAPE 4: Fixer le support frontal sur le plnum 1. Alignez le support frontal sur le plnum. 2. Fixez le support frontal sur le plnum laide des 6 vis fournies.

TAPE 3: Ajuster le sparateur (si ncessaire) 1. Retirez les 2 vis avant et desserrez les 2 vis arrire. 2. Glissez le sparateur vers la grille jusqu ce quil sappuie sur celle-ci dune faon tanche. 3. Serrez les 2 vis arrire.

Vis arrire

Vis avant

Serrer les vis arrire

Sparateur gliss en position contre la grille extrieure

4

Notes

Imprim aux tats-Unis

Instrucciones de Instalacin para su nuevo RAVTRANS3 Plnum de Transicin Para reemplazar las unidades de las series AZ90, AZ91 con una profundidad de pared exterior de entre 5.5 y 8

Antes de comenzar lea estas instrucciones completamente y de forma detenida. IMPORTANTE- CUMPLA CON TODOS LOS CDIGOS Y ORDENANZAS GUBERNAMENTALES. Nota para el Instalador Asegrese de entregar estas instrucciones al Consumidor. Nota para el Consumidor Guarde estas instrucciones con su Manual del Propietario para referencia futura.

31-5000569 Rev. 0 11-20 GEA

El RAVTRANS3 se ajustar al kit de plnum RAVTWPT8 de GE Appliances existente.

El kit RAVTRANS3 es necesario al reemplazar un acondicionador de aire vertical de las series AZ90/AZ91 por un acondicionador de aire vertical nuevo de la serie AZ95 instalado en un plnum de pared RAVWPT8. El RAVWPT8 es un plnum telescpico de chapa metlica usado en instalaciones de AZ90/AZ91 con paredes exteriores de un grosor inferior a 8 pulgadas. Las diferencias en los diseos de chasis entre las series AZ90/AZ91 y AZ95 requieren de una planificacin detallada de su instalacin. Los cambios en las ubicaciones de las salidas del drenaje y sus recorridos, las conexiones elctricas, la altura de la plataforma, y el conducto del acondicionador de aire son todos temas que se debern tener en cuenta al reemplazar una unidad de la serie AZ91/AZ91 por una unidad de la serie AZ95.

GE Appliances es una marca de General Electric Company. Fabricado bajo licencia de la marca.

Piezas Incluidas Plnum de Transicin con Divisor de Aire 10 tornillos metlicos n 10 y longitud de para chapa

con cabeza hexagonal de 5/16 Soporte Frontal

Informacin General de la Instalacin

Plnum

Divisor de Aire

Soporte Frontal

Unidad*

Incluido en RAVTRANS3

RAVDPLAT*

RAVTRANS3

Exterior/ Pared Externa

Exterior del Plnum de Pared Existente RAVWPT8*

Persiana Arquitectnica Existente*Interior del Plnum

de Pared Existente RAVWPT8*

*Se Adquiere por Separado

2

Instrucciones de Instalacin PASO 1: Prepare el rea de Instalacin Retirando la Unidad AZ90/AZ91 y el Plnum de Pared Interior RAVWPT8 Existente WARNING Existe riesgo de descargas elctricas que pueden ocasionar lesiones o la muerte. Antes de

active de forma accidental. Para retirar la unidad de las series AZ90/AZ91: 1. Desconecte la corriente que ingresa a la unidad desde el panel del disyuntor principal o desde la desconexin montada en el armario. 2. Retire la desconexin de corriente del frente de la unidad. 3. Retire el panel frontal. 4. Desconecte los cables de corriente de la unidad. 5. Desconecte los cables del termostato de la unidad. 6. Desconecte todo el drenaje. 7. Desconecte el conducto de aire que se encuentra sobre la unidad. 8. Retire la unidad. 9. Retire la plataforma. 10. Retire el plnum de pared interior RAVWPT8. No retire la mitad exterior del RAVWPT8 o la rejilla exterior existente.

PASO 2: Instale y Conecte el Plnum de Transicin al Plnum de Pared Existente NOTA: El RAVTRANS3 se ajustar dentro del plnum exterior RAVWPT8 existente. 1. Inserte el RAVTRANS3 en el plnum existente y asegrese de que quede completamente instalado las bridas de pared debern tener contacto con el lado interior de la pared. 2. Coloque el RAVTRANS3 1 o 2 hacia afuera y aplique sellador sobre el lado exterior de la brida de pared en sus partes superior, inferior y laterales. 3. Inserte completamente el RAVTRANS3 hasta que las bridas de pared estn niveladas contra el lado interior en su totalidad, comprimiendo el sellador. 4. Selle la parte interior del plnum a lo largo de la unidad, entre los plnums interior y exterior. Selle por lo menos 3 en la parte inferior y superior a cada lado. 5. Selle cualquier brecha entre el plnum y la pared tanto en los laterales como en la parte inferior. 6. Asegure el plnum interior al plnum exterior usando los tornillos suministrados. No coloque los tornillos en la parte inferior del plnum.

Conducto Rgido

Pared Interior

Panel de Acceso o Puerta del Armario

Retiro del Plnum de Pared Interior RAVWPT8 Existente

Plnum de Pared

Exterior RAVWPT8

Existente

Rejilla Exterior Existente

Una vez completado, el rea del armario deber verse as.

Sellado

Plnum de Pared Exterior RAVWPT8 Existente

Rejilla Exterior Existente

Sellado

SelladoRejilla Exterior Existente

RAVWPT8 Exterior Existente

Pared Exterior

RAVTRANS3

Alinee el RAVTRANS3 con el Plnum Existente

3

Instrucciones de Instalacin

PASO 4: Adhiera el Soporte Frontal al Plnum. 1. Alinee el soporte frontal con el plnum. 2. Ajuste el soporte frontal al plnum con los 6 tornillos provistos.

PASO 3: Ajuste el Divisor (si corresponde)

2. Deslice el divisor hacia la rejilla hasta que quede sellada contra la rejilla. 3. Ajuste los 2 tornillos traseros.

Tornillos Traseros

Tornillos Frontales

Tornillos Traseros

Divisor movido has- ta la posicin cont

Manualsnet FAQs

If you want to find out how the RAVTRANS3 GE works, you can view and download the GE RAVTRANS3 Plenum Installation Instructions on the Manualsnet website.

Yes, we have the Installation Instructions for GE RAVTRANS3 as well as other GE manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Installation Instructions should include all the details that are needed to use a GE RAVTRANS3. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the GE RAVTRANS3 Plenum Installation Instructions is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This GE RAVTRANS3 Plenum Installation Instructions consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download GE RAVTRANS3 Plenum Installation Instructions free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print GE RAVTRANS3 Plenum Installation Instructions, simply download the document to your computer. Once downloaded, open the PDF file and print the GE RAVTRANS3 Plenum Installation Instructions as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.