BEFORE YOU BEGIN Read these instructions completely and carefully.

IN THE COMMONWEALTH OF MASSACHUSETTS:

This product must be installed by a licensed plumber or gas fitter.

When using ball-type gas shut-off valves, they shall be the T-handle type.

A flexible gas connector, when used, must not exceed 3 feet.

IMPORTANT Save these instructions for local inspectors use.

IMPORTANT Observe all governing codes and ordinances.

IMPORTANT Leak testing of the appliance shall be conducted according to the manufacturers instructions.

Note to Installer Be sure to leave these instructions with the Consumer.

Note to Consumer Keep these instructions for future reference.

Skill level Installation of this appliance requires basic mechanical skills.

Completion time 1 to 3 hours Proper installation is the responsibility of the installer.

Product failure due to improper installation is not covered under the Warranty.

WARNING This appliance must be properly grounded.

FOR YOUR SAFETY WARNING If the information in this manual is

not followed exactly, a fire, explosion or gas leak may result, causing property damage, personal injury or death. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE!

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance. Do not touch any electrical switch; do not use any

phone in your building. Immediately call your gas supplier from a

neighbors phone. Follow the gas suppliers instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Be sure your oven is installed properly by a qualified installer or service technician.

Be sure the oven is securely installed in a cabinet that is firmly attached to the house structure. Weight on the oven door could cause the oven to tip, resulting in serious personal injury or death. Never allow anyone to climb, sit,

Installation Instructions

24 Gas Built-In Oven JGRP20

If you have questions, call GE Appliances at 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com.

31-2000792 Rev. 0 07-20

2 31-2000792 Rev. 0

TOOLS YOU WILL NEED

12 Spirit Level

Safety Glasses

Drill with 1/8 Bit

Pencil

Installation Preparation

Adjustable Wrench

Pipe wrench

3/16 Hex Socket Driver

#1 or #2 Phillips Screwdriver

Ruler

Hand Saw

MATERIALS YOU MAY NEED

FOR FLEXIBLE CONNECTION WHERE LOCAL CODES PERMIT: Coated and approved flexible metal tubing (same

Adaptor or connector

FOR RIGID CONNECTION: Pipe fittings or union as required

Gas line shut-off valve

Pipe joint sealant 1/2 pipe nipple

1 GAS REQUIREMENTS You must follow local codes when installing your built-in oven. Check with your local utilities for codes and ordinances that apply in your area. If there are no local codes, you must follow the National Fuel Gas Code ANSI/Z223.1 Latest Edition. To get a copy write to:

American Gas Association 1515 Wilson Boulevard

This standard does not cover the thermal efficiency of household cooking gas appliances since it is regulated by the Energy Policy and Conservation Act of 1975, the National Energy Conservation Policy Act of 1978 and the National Appliance Energy Conservation Act of 1987. If the oven is to be installed in a mobile home, the installation must conform to the Manufactured Home Construction and Safety Standard, Title 24, CFR, Part 3280 or, when not applicable, the Standard for Manufactured Home Installations ANSI/ A225.1 Latest Edition and Manufactured Home Installations, Sites and Communities ANSI/ NFPA 501A, or with local codes. You can get a copy of the Federal Standard by writing:

Office of Mobile Home Standards HUD Building

451 7th Street, S.W. Washington, D.C. 24010.

2 ELECTRICAL REQUIREMENTS This appliance must be electrically grounded. Check with your local codes which apply in your area. If no local codes apply, the National Electrical Code, ANSI/NFPA No. 70 Latest Edition must be followed. Write to: NATIONAL FIRE PROTECTION ASSOCIATION BATTERYMARCH PARK QUINCY, MA 02269

31-2000792 Rev. 0 3

Installation Preparation

3 PREPARE THE OPENING

Its best to use a template to make a straight cut. Place

floor.

* SHOULD BE ADJUSTED TO SUIT BOTH STANDARD CABINETRY AND DESIRED OVEN WORKING HEIGHT

The cabinet must have solid sides, back and bottom. The bottom must be solid either at floor level or with the bottom edge of the cutout. Any openings around the gas or

electrical outlets must be sealed. All cabinet openings must be sealed at the time of installation to prevent drafts. Drafts will affect safe use of the oven. SPECIAL NOTES: Make sure the oven is installed at the specified height.

The unit has been tested and approved for installation, in accordance with safety standards at this height.

If the floor is to be the solid bottom, two runners,

used to support the oven. These runners must support 130 lbs. and must be level and straight.

The wall coverings, countertops and cabinets around the oven should be able to withstand temperatures of up to 200F generated by the oven.

IF YOU ARE REPLACING A UNIT THAT HAS A

A. Shut off the main gas supply before removing the existing oven. Leave the gas off until the new hookup is complete.

B. C. Raise your gas inlet pipe if necessary. D. Remove the storage drawer. E.

F. Insert the oven into the cutout and adjust the levelers so that the oven racks are level and the top of the control panel overlaps the top of the cutout.

24 Min.

24 Min.

38 39

22 to 28

22-3/16

23-3/4

2 Runners on 11 Centers

Fig. 1

Oven

Fig. 2

3/8 Min.

Wall or Cabinet

3/16 Slotted Hex Head

Leg Leveler

Fig. 3

4 31-2000792 Rev. 0

Installation Instructions

4 ELECTRICAL CONNECTIONS An adequate electrical supply and outlet must be used to operate the electrical parts of your oven. A. The oven cord has a three-prong plug and must be

used with a properly grounded three-hole outlet with a standard 120 Volt, 60 cycle AC household current.

B. Install the electrical outlet below the oven on the left side, in a location that is easily reached through the

C. If you do not have a three-hole grounded outlet, have a qualified electrician change your old one.

D. A grounding adaptor will be needed to convert the old one until the outlet can be replaced. This method is only temporary, and a qualified electrician should test it to be sure it meets requirements.

Always unplug the oven cord before making any electrical repairs to the oven. When unplugging the oven, always grasp the plug, never the cord.

WARNING NEVER USE AN EXTENSION CORD TO CONNECT THE OVEN TO THE ELECTRICAL SUPPLY.

WARNING Do not under any circumstances cut or remove grounding prong from oven cord. Failure to provide proper polarization may create a hazardous condition.

5 GAS CONNECTIONS

WARNING Do not operate the burners of this oven when using LP (bottled) gas before converting the pressure regulator and burner orifice for LP gas usage. See page 2 for all gas requirements. A. Shut off the gas supply at the shut-off valve. B. C. Discard any old or used connectors.

WARNING Never reuse old flexible connectors. The use of old flexible connectors can cause gas leaks and personal injury. Always use new connectors when installing a gas appliance. D. Be sure no strain has been placed on the

connecting line assembly. To prevent any leaks, use a pipe joint compound that resists the action of LP gas on the male outside threads.

E. F.

front surface of the cabinet.

G. Install a shut-off valve to the pipe. H. Remove the storage drawer and the oven door.

L

N

Plug with ground prong properly polarized and grounded receptacle.

Polarized receptacle properly grounded.

Metal Eyelet Ground

Receptacle Plate Mounting ScrewPreferred Method

Temporary Method Fig. 4

Fig. 5 Recommended Main Shut-Off Location (The regulator also has a shut-off lever)

8-1/2 Min. 9-5/8 Max.

22

13-1/2 22 to 28

Fig. 6

INSTALL THE OVEN

31-2000792 Rev. 0 5

Installation Instructions

5 GAS CONNECTIONS (Cont.) I. Place the oven in the cutout. J. Level the oven:

1. Place a spirit level on one of the oven racks. 2. If the oven is not level, adjust the leg levelers. 3. Remove regulator cover at the back of the storage

drawer area by removing 4 screws. With the oven in place, the pressure regulator inlet is accessible through the opening in the main back.

K. Through this opening connect: 1. or 2. The rigid pipe connection and union to the shutoff

L. Tighten the fitting.

WARNING DO NOT FORCE! FORCING COULD DAMAGE THE FITTING, TUBING OR CAUSE LEAKING.

6 CHECK FOR LEAKS

WARNING DO NOT USE OPEN FLAME TO CHECK FOR LEAKS! A. Apply a soap solution to all connections: supply line,

manifold and oven. B. Turn on the main gas supply. C. Check for any bubbles to form. D. Turn off main gas supply. E. Stop any leaks found. F. Turn main gas supply on to make sure all leaks were

stopped. G. Replace the regulator cover using the 4 screws

previously removed.

WARNING ALL LEAKS MUST BE STOPPED BEFORE ATTEMPTING TO LIGHT BURNERS.

7 PRESSURE TEST INFORMATION A. The maximum allowable pressure for the regulator is

B. The minimum pressure needed to check the

for Natural.

CAUTION The range and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of the gas supply system at test pressures in excess of 1/2 psig (pound per square inch gauge). The range must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply system at test pressures equal to or less than 1/2 psig.

Union

RIGID HOOK-UP

Pressure Regulator

Regulator Cover Plate

FLEXIBLE HOOK-UP

Pressure Regulator with Built-In Shut-Off

Valve

Adaptor Flexible Connection

Regulator Cover Plate

Fig. 7

Fig. 8

6 31-2000792 Rev. 0

Installation Instructions

8 CHECK THE BURNER FLAMES FOR NATURAL GAS

The oven is factory-adjusted for use with Natural Gas in most areas. But, since the gas in some areas may vary, you should check all adjustments described below. If you are to use LP Gas, see LP Adjustments at the back of this guide.

NOTE: Bake and broil flame must be checked with the door closed to properly check flame characteristics. To properly check the bake burner, the oven bottom and oven baffle must be removed.

Turn on the bake or broil burner. As you watch the flame with the oven door closed, check the following through the oven door window: 1. Burner flames should not flutter or blow away

from the burner. 2. T hey should be blue in color with no trace of

yellow. 3. The inner cone of the flame should be

BURNERS SHOULD BE CHECKED FREQUENTLY.

9 MAKE THE BURNER FLAME ADJUSTMENTS (Cont.)

E. Use a screwdriver to loosen the air shutter screw. 1. If the flames were yellow, open the air shutter

more than the original setting. 2. If the flames blew away or fluttered from the

burner, close the air shutter more than the original setting.

F. Make the adjustment. G. Retighten the air shutter screw. H. Close the door and recheck the flame. When the results are satisfactory:

1. Replace the orifice fitting cover. 2. 3. Replace the oven bottom.

BROIL BURNER A. The broil burner is located and accessible in the top

rear of the oven. B. Use a screwdriver to loosen the air shutter

adjustment screw. 1. Check air shutter to ensure its in the fully open

position and clear of any obstructions. For NG application ensure that the regulator is in the NG position. For LP applications ensure that the hood has been tightened to the LP position.

2. If the flames blew away or fluttered from the burner, close the air shutter more than the original setting.

C. Make the adjustment. D. Retighten the air shutter screw. E. Close the oven door and recheck the flame.

9 MAKE THE BURNER FLAME ADJUSTEMENT

BAKE BURNER A. Open the oven door. B. Remove the oven bottom. C.

D. Remove orifice fitting cover.

INSTALL THE OVEN (Cont.)

Oven Bottom Burner Baffle

Fig. 9

Air Shutter Orifice Fitting Cover

Air Shutter Screw Fig. 10

31-2000792 Rev. 0 7

Installation Instructions

10 SECURE THE OVEN IMPORTANT: Remove all packing material and literature from the oven before connecting any electrical supplies.

A. Using a 1/8 drill bit, drill holes through the side trim and into the cabinet front.

B. With the screws provided, secure the oven to the wall.

C. If the cabinet cutout is 38 high, use the short trim and attach to the bottom of the front frame, with screws provided.

11 RECHECK STEPS Double check to make sure everything in this guide has been completed. Rechecking steps will ensure safe use of the oven.

WARNING The trim permits air entry into the cabinet below the unit and must not be blocked.

8 31-2000792 Rev. 0

Installation Instructions

1 ADJUST PRESSURE REGULATOR FROM NATURAL GAS TO LP (Cont.)

D. Remove the retainer from the cap. E. Turn the retainer over so LP is showing on the

bottom of the retainer. F. Return the retainer inside the cap. G. Replace the cap on the regulator. H. Replace the Regulator Cover Plate using the 2

screws that held it originally.

1 ADJUST PRESSURE REGULATOR FROM NATURAL GAS TO LP

A. Remove the Regulator Cover Plate at the back of the storage drawer area by removing 2 screws.

B. Locate the regulator.

C. Unscrew the cap. Fig. 11

MAKE THE LP GAS CONVERSION

WARNING If you are using LP (bottled) gas, all the adjustments described below must be made before you make any burner adjustments or use the oven.

WARNING This conversion must be performed by a qualified installer or gas supplier in accordance with the manufacturers instructions and all codes and requirements of the authority having jurisdiction. Failure to follow instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for the conversion. NOTE: Disconnect all electrical power and turn off the gas supply at the shut-off valve before beginning the conversion.

NAT. l..P.

Cap Gasket

Spring Retainer

LP Nat

Fig. 12

2 ADJUST BURNER ORIFICE FROM NATURAL TO LP GAS

CAUTION The adjustments in the next column must be made before turning on the burners. Failure to do so could result in serious injury due to high flames and toxic fumes. Your Broil burner is located in the upper portion of the oven and is easilly accessible. To access your Bake burner follow the steps below: A. Open the oven door. B. Remove the oven bottom. C. Remove 4 screws holding the oven baffle (flame

D. Remove the orifice fitting cover.

Oven Bottom Burner Baffle

Fig. 13

Air Shutter Orifice Fitting Cover

Air Shutter Screw Fig. 14

FLEXIBLE HOOK-UP

Pressure Regulator with Built-In Shut-Off

Valve

Adaptor Flexible Connection

Regulator Cover Plate

31-2000792 Rev. 0 9

Installation Instructions

3 FOR BAKE AND BROIL BURNERS Use a 1/2 open end or adjustable wrench to turn the orifice hood in the LP direction, about 1-1/2 turns, until snug.

IMPORTANT: Do not overtighten or you may bend the orifice hood or needle.

5 ADJUST AIR SHUTTER NOTE: The Bake and Broil burner flame must be checked with the door closed to properly check flame characteristics. Turn on the bake or broil burner. As you watch the flame with the oven door closed, check the following through the oven door window: A. Burner flames should not flutter or blow away from

the burner. B. They should be blue in color with no trace of yellow. C. The inner cone of the flame should be approximately

1/2 to 3/4 long. IN SOME CASES A. With LP gas, some yellow tipping on the outer cone

is normal. B. Foreign particles in the gas line may cause an

orange flame at first, but this will soon disappear.

4 CHECK FLAME SIZE Check the inner cone of the flame. It should be approximately 1/2 to 3/4 long for the oven and broil burners until snug. If the flame size is too long, use a 1/2 open-end wrench or adjustable joint pliers to adjust the orifice hood, by turning in the LP direction.

WARNING If you attempt to measure the inner cone of the flame, please use caution; burns could result.

NAT.

NAT.

NAT.-LP Adjustment Made to Orifice Hood

LP

LP

Air Shutter

Air Shutter

Air Shutter Screw

Fig. 15

Fig. 16

Bake Burner

Broil Burner

1/2 to 3/4

Inner Cone of Flame

Fig. 17

A Yellow Flames Call for Service

B Yellow Tipping

Normal for LP Gas

C Soft Blue Flames

Normal for Natural Gas

Fig. 18

10 31-2000792 Rev. 0

Installation Instructions

5 ADJUST AIR SHUTTER (Cont.) BAKE BURNER

A. Use a screwdriver to loosen the air shutter screw. 1. If the flames were yellow, open the air shutter

more than the original setting. 2. If the flames blew away or fluttered from the

burner, close the air shutter more than the original setting.

B. Make the adjustment. C. Retighten the air shutter screw. D. Close the oven door and recheck the flame. E. When all adjustments are made and the results are

satisfactory: 1. Replace the orifice fitting cover. 2. 3. Replace the oven bottom.

5 ADJUST AIR SHUTTER (Cont.) BROIL BURNER A. The broil burner is located and accessible in the top

rear of the oven. B. Use a screwdriver to loosen the air shutter

adjustment screw. 1. Check air shutter to ensure its in the fully open

position and clear of any obstructions. For NG application ensure that the regulator is in the NG position. For LP applications ensure that the hood has been tightened to the LP position.

2. If the flames blew away or fluttered from the burner, close the air shutter more than the original.

C. Make the adjustment. D. Retighten the air shutter screw. E. Close the oven door and recheck the flame.

SPECIAL NOTE: To convert the oven back to natural gas, reverse the instructions given in making LP Adjustments.

WARNING Once the conversion is complete, locate the LP Conversion Sticker under the storage drawer on the main bottom. When the Conversion checks OK, fill out the LP sticker and include your name, organization and date conversion was made. Apply the sticker to the front frame opposite the name and number plate behind the storage drawer to alert others in the future that this appliance has been converted to LP If converting back to natural gas from LP, please remove the sticker so others know the appliance is set to use natural gas.

MAKE THE LP GAS CONVERSION (Cont.)

Air Shutter Orifice Fitting Cover

Air Shutter Screw Fig. 19

Air Shutter Screw

Air Shutter

Fig. 20

31-2000792 Rev. 0 1

ANTES DE EMPEZAR: Lea estas instrucciones y las advertencias completa y cuidadosamente.

EN LA MANCOMUNIDAD DE MASSACHUSETTS:

Este producto debe ser instalado por un plomero licenciado o por un tcnico de gas.

Cuando se encuentre usando vlvulas de desconexin de gas tipo bola, deben ser del tipo T.

Un conectador de gas flexible,

IMPORTANTE Guarde estas instrucciones para su uso por el inspector local.

IMPORTANTE Observe todos los codigos y ordenanzas vigentes.

IMPORTANTE La prueba de escape de gas del aparato deber conducirse de acuerdo a las instrucciones del fabricante.

Nota al instalador Asegrese de dejar estas instrucciones con el cliente.

Nota al consumidor Guarde estas instrucciones para referencia futura.

Nivel de destreza La instalacin de este aparato requiere de destrezas mecnicas bsicas.

Tiempo de instalacin 1 a 3 horas La instalacin apropiada es la responsabilidad del instalador.

La falla del producto debido a una instalacin inadecuada no est cubierta por la garanta.

ADVERTENCIA Este aparato debe hacer tierra adecuadamente.

PARA SU SEGURIDAD: ADVERTENCIA Si la informacin en este manual

no se sigue exactamente, podra resultar un incendio, una explosin o un escape de gas que causen dao a la propiedad, heridas personales o muerte. NO ALMACENE O USE GASOLINA U OTROS VAPORES O LIQUIDOS INFLAMABLES CERCA DE ESTE O CUALQUIER APARATO ELECTRODOMSTICO!

QUE HACER SI HUELE GAS:

No trate de encender ningn aparato. No toque ningn interruptor elctrico; no use

ningn telfono en su edificio. Inmediatamente llame a su abastecedor de

gas usando el telfono de un vecino. Siga las instrucciones del abastecedor de gas.

Si no puede comunicarse con el abastecedor de gas, llame a la compaa de bomberos.

La instalacin y el servicio deben ser hechos por un instalador competente, una agencia de servicio o el abastecedor de gas.

Asegrese que su horno sea instalado adecuadamente por un instalador competente o un tcnico de servicio.

Asegrese que el horno quede bien instalado en un gabinete que est firmemente pegado a la estructura de la casa. Peso sobre la puerta puede causar que el horno se vuelque resultando en serias heridas personales o muerte. Nunca permita que alguien se suba, se afirme, se pare o se cuelgue de la puerta del horno.

Instrucciones de Instalacin

Horno A Gas Empotrado de 24

JGRP20

Preguntas? Llame al 1.800.GE.CARES (800.432.2737) o bien visite nuestra pgina Web: GEAppliances.com

2 31-2000792 Rev. 0

LISTA DE HERRAMIENTAS

Gafas de seguridad

Lpiz

Preparacin de Instalacin

Llave inglesa ajustable

Llave inglesa para caeras

Soquete hexagonal

Destornillador Phillips No. 1 o No. 2

Regla y vara derecha para medir

Sierra manual o elctrica

MATERIALES ADICIONALES QUE PODRA NECESITAR:

PARA CONEXIONES FLEXIBLES DONDE LAS PERMITAN LOS CDIGOS LOCALES:

I.D. igual a la lnea abastecedora del gas) Adaptador o conector

PARA CONEXIONES RGIDAS: Junturas o uniones para caeras requeridas

Vlvula de cierre para la lnea del

gas

Sello para las uniones de caeras

1/2 pipe nipple

1 REQUERIMIENTOS DE GAS Usted debe cumplir con los cdigos locales cuando instale su horno. Consulte con su compaa de gas local acerca de las leyes y ordenanzas locales que se aplican en su rea. Si no existen cdigos locales, usted debe cumplir con el National Fuel Gas Code ANSI/Z223.1 Latest Edition. Para obtener una copia escriba a:

American Gas Association 1515 Wilson Boulevard

Arlington (Rosslyn), VA 22209 Esta norma no cubre la eficiencia termal de los aparatos para cocinar a gas de la casa ya que esto es regulado por la Energy Policy and Conservation Act de 1975, la National Energy Conservation Policy Act de 1978 y la National Appliance Energy Conservation Act de 1987. Si el horno va a ser instalado en una casa mvil, la instalacin debe cumplir con Manufactured Home Construction and Safety Standard, Title 24, CFR, Part 3280 o, cuando no es aplicable, el Standard for Manufactured Home Installations ANSI/A225.1 Latest Edition and Manufactured Home Installations, Sites and Communities ANSI/NFPA 501A, o con los cdigos locales. Usted Puede obtener una copia del Federal Standard escribiendo a::

Office of Mobile Home Standards HUD Building

451 7th Street, S.W. Washington, D.C. 24010.

2 REQUERIMIENTOS ELCTRICOS Este aparato debe hacer tierra. Consulte los cdigos locales que se aplican en su rea. Si no existen cdigos locales, debe cumplir con el National Electrical Code, ANSI/NFPA No. 70 Latest Edition. Escriba a: NATIONAL FIRE PROTECTION ASSOCIATION BATTERYMARCH PARK QUINCY, MA 02269

31-2000792 Rev. 0 3

Instrucciones de Instalacin

3 PREPARE LA ABERTURA

(Vea Fig. 2) Es buena idea usar un molde para hacer un corte derecho.

* DEBERA SER AJUSTADO PARA ACOMODAR LOS GABINETES NORMALES Y LA ALTURA DEL HORNO.

El gabinete debe tener fondo, posterior y lados slidos. El fondo debe ser slido, a nivel del piso o con el borde slido del fondo del corte. Todas las aberturas del gabinete deben estar selladas

en el momento de la instalacin para prevenir corrientes de aire. Las corrientes de aire afectarn el uso seguro del horno. NOTAS ESPECIALES: Asegrese de instalar el horno a la altura especificada. La

unidad ha sido probada y aprobada para la instalacin de acuerdo a las normas de seguridad a esta altura.

Si el piso va a ser el fondo slido, dos soportes, centrados

sujetar el horno. Estos soportes deben sostener 130 libras y deben ser nivelados y derechos.

Los revestimientos de las paredes, la superficie de los mesones y los gabinetes alrededor del horno deberan soportar

SI EST REEMPLAZANDO UNA UNIDAD QUE TIENE UN

A. Cierre el suministro de gas principal antes de sacar el horno existente. Deje el gas apagado hasta que la nueva conexin haya sido completada.

B. C. evante la caera de entrada del gas si es necesario. D. Saque el cajn. E. Extienda los niveladores de las patas (con un soquete

F. Encaje el horno en el corte y ajuste los niveladores de manera que las parrillas del horno queden niveladas y que la parte de arriba del panel de control quede sobre la parte superior del corte.

24 Min.

24 Min.

38 39

22 to 28

22-3/16

23-3/4

2 Soportes Fig. 1

Horno

Fig. 2

3/8 Min.

Pared o Gabinete

Cabeza Hexagonal de

Nivelador de Pata

Fig. 3

4 31-2000792 Rev. 0

Instrucciones de Instalacin

4 CONEXIONES ELCTRICAS Un abastecimiento y receptculo elctrico adecuado debe ser usado para operar las partes elctricas de su horno. A. El cordn del horno tiene un enchufe de tres patas y debe

ser usado con un receptculo de tres hoyos que haga tierra adecuadamente con corriente alterna normal de casa de 120 Voltios, 60 Ciclos.

B. Instale el receptculo elctrico ms abajo del horno en el lado izquierdo, en un lugar donde se pueda alcanzar fcilmente a travs de las puertas del gabinete. (Vea Fig. 6).

C. Si no tiene un receptculo de tres hoyos que haga tierra, haga que un electricista calificado le cambie el antiguo.

D. Un adaptador para hacer tierra se necesitar para convertir el receptculo viejo hasta que pueda ser reemplazado. Este mtodo es slo provisorio, y un electricista calificado lo debera probar para estar seguro que cumple con los requerimientos.

Siempre desenchufe el cordn del horno antes de hacer cualquier reparacin al horno. Cuando desenchufe el horno, siempre tome el enchufe, nunca el cordn.

ADVERTENCIA NUNCA USE UN CORDN DE EXTENSIN PARA CONECTAR EL HORNO A LA ELECTRICIDAD.

ADVERTENCIA Bajo ninguna circunstancia corte o saque la pata para hacer tierra del cordn del horno. No proveer una polarizacin adecuada podra crear una condicin peligrosa.

5 CONEXIONES DEL GAS ADVERTENCIA No haga funcionar los quemadores

de este horno cuando use gas LP (embotellado) antes de convertir el regulador de presin y el orificio del quemador para uso con gas LP. Vea la pgina 2 para todos los requerimientos de gas. A. Cierre el suministro del gas en la vlvula de cierre. B. Saque el horno existente (si es necesario). C. Bote todos los conectores viejos o usados.

ADVERTENCIA Nunca reutilice conectores flexibles viejos. El uso de conectores flexibles viejos puede causar escapes de gas y heridas personales. Siempre utilice conectores nuevos cuando instale una estufa a gas. D. Asegrese de no ejercer presin sobre el juego de la lnea

de conexin. Para prevenir cualquier escape, use un compuesto para unin de caeras que sea resistente al gas LP sobre los hilos machos exteriores.

E. F.

detrs del frente de la superficie del gabinete.

G. Instale la vlvula de cierre en la caera. H. Saque el cajn y la puerta del horno.

L

N

Enchufe con pata para hacer tierra polarizado adecuadamente y receptculo que hace tierra

Receptculo polarizado que hace tierra adecuadamente

Ojo de metal para hacer tierra

Tornillo de montaje para la placa del receptculo

Mtodo Preferido

Mtodo Provisorio Fig. 4

Fig. 5

Ubicacin Recomendada del Cierre Principal (El regulador tambin tiene una manilla de cierre)

8-1/2 Min. 9-5/8 Max.

22

13-1/2 22 to 28

Fig. 6

INSTALACIN DEL HORNO

31-2000792 Rev. 0 5

Instrucciones de Instalacin

5 CONEXIONES DEL GAS (Cont.) I. Coloque el horno en el corte. J. Nivele el horno:

1. Coloque el nivel de espritu sobre una de las parrillas del horno.

2. Si el horno no est nivelado, ajuste los niveladores de las patas.

3. Remueva la cubierta del regulador en la parte posterior del rea del cajn de almacenamiento, removiendo los 4 tornillos.

Con el horno en su lugar, la entrada del regulador de presin es accesible a travs de la abertura en la espalda principal.

K. A travs de esta abertura conecte: 1. La conexin flexible y el adaptador (vea Fig. 7). or 2. La conexin de caeras rgidas y la unin a la vlvula

de cierre (vea Fig. 8).

L. Apriete las conexiones.

ADVERTENCIA NO FUERCE! SI FUERZA PODRA DAAR LAS UNIONES, LAS CAERAS O CAUSAR ESCAPES.

6 REVISE QUE NO HAYAN ESCAPES ADVERTENCIA NO USE UNA LLAMA ABIERTA

PARA VER SI EXISTEN ESCAPES DE GAS! A. Aplique una solucin de jabn a todas las conexiones:

lnea de abastecimiento, caeras y horno. B. Abra el suministro principal del gas. C. Vea si se forman burbujas. D. Cierre el suministro principal del gas. E. Detenga cualquier escape que haya encontrado. F. Abra el suministro principal del gas para asegurarse que

todos los escapes han sido detenidos. G. Coloque nuevamente la cubierta del regulador usando los

4 tornillos que se removieron previamente.

ADVERTENCIA TODOS LOS ESCAPES DE GAS DEBEN SER DETENIDOS ANTES DE TRATAR DE ENCENDER LOS QUEMADORES.

7 INFORMACIN PARA PRUEBAS DE PRESIN

A. W.C. (Columna de Agua).

B. La presin mnima necesitada para probar la calibracin

gas natural.

PRECAUCIN El horno y su vlvula de cierre individual debe ser desconectado del sistema de la lnea abastecedora de gas durante cualquier prueba de presin en exceso de 1/2 psig (libra por pulgada cuadrada gauge). El horno debe ser aislado del sistema de abastecimiento de gas cerrando su vlvula de cierre manual durante cualquier prueba al sistema de abastecimiento de gas igual o menor a 1/2 psig.

INSTALACIN DEL HORNO (Cont.)

Unin

INSTALACIN RGIDA

Regulador de Presin

Placa de Cubierta del Regulador

INSTALACIN FLEXIBLE

Regulador de Presin con

Vlvula de Cierre Incorporada

Adaptador Conexin Flexible

Placa de Cubierta del Regulador

Fig. 7

Fig. 8

6 31-2000792 Rev. 0

Instrucciones de Instalacin

8 CMO REVISAR LAS LLAMAS DE LOS QUEMADORES A GAS NATURAL

El horno viene ajustado de fbrica para ser usado con gas natural en la mayora de las reas. Pero, como el gas en algunas reas vara, usted debe revisar todos los ajustes que se describen ms abajo. Si usted va a usar gas LP, mire los Ajustes para Gas LP en la parte final de esta gua. NOTA: La llama para hornear y asar a la parrilla debe ser revisada con la puerta cerrada para revisar adecuadamente las caractersticas de la llama. Para revisar correctamente el quemador para hornear, el fondo del horno y el esparcidor de llamas deben ser removidos. Encienda el quemador para hornear o asar.

Mientras mire la llama con la puerta del horno cerrada, revise lo siguiente a travs de la ventana de la puerta: 1. Las llamas del quemador no deberan pestaear o

soplar en direccin opuesta al quemador. 2. Deberan ser de color azul sin muestras de amarillo. 3.

de longitud.

LOS QUEMADORES DEBERAN SER REVISADOS FRECUENTEMENTE.

9 CMO AJUSTAR LAS LLAMAS DEL QUEMADOR (Cont.)

E. Use un destornillador para soltar el tornillo del obturador de aire. 1. Si las llamas estaban amarillas, abra el obturador ms

que la posicin original. 2. Si las llamas soplaban en direccin opuesta al

quemador, cierre el obturador ms que la posicin original.

F. Haga el ajuste. G. Apriete nuevamente el tornillo del obturador. H. Cierre la puerta y revise nuevamente la llama. Cuando los resultados son satisfactorios:

1. Coloque nuevamente la cubierta del orificio. 2. Coloque el esparcidor de llamas en su lugar. 3. Coloque nuevamente el fondo del horno.

QUEMADOR PARA ASAR A. El quemador para asar est ubicado y es accessible en la

parte superior trasera del horno. B. Use un destornillador para soltar el tornillo de ajuste del

obturador. 1. Controle el obturador de aire para asegurar que se

encuentre en la posicin completamente abierta y libre de cualquier obstruccin. Para la aplicacin NG, asegrese de que el regulador se encuentre en la posicin NG. Para las aplicaciones de LP, asegrese de que la campana se haya ajustado en la posicin LP.

2. Si las llamas soplaban en direccin opuesta al quemador, cierre el obturador ms que la posicin original.

C. Haga el ajuste. D. Apriete nuevamente el tornillo del obturador. E. Cierre la puerta del horno y revise nuevamente la llama.

9 CMO AJUSTAR LAS LLAMAS DEL QUEMADOR

QUEMADOR DEL HORNEAR A. Abra la puerta del horno. B. Saque el fondo del horno. C. Saque los 4 tornillos para remover el esparcidor de

llamas..

D. Saque la cubierta del orificio.

INSTALACIN DEL HORNO (Cont.)

Esparcidor del quemador fondo del horno

Fig. 9

Obturador de Aire Cubierta del Orificio

Tornillo del Obturador de Aire Fig. 10

31-2000792 Rev. 0 7

Instrucciones de Instalacin

10 CMO COLOCAR BIEN EL HORNO IMPORTANTE: Saque todos los materiales de empaque y la literature del horno antes de hacer cualquier conexin elctrica.

A. molduras laterales y en el frente del gabinete.

B. Con los tornillos que se proveen, asegure el horno a la pared.

C. moldura corta y pguela al fondo del marco frontal con los tornillos que se proveen.

ms alta).

11 REVISE LOS PASOS Revise varias veces para asegurarse que todo en esta gua ha sido completado. El revisar los pasos le asegurar la utilizacin segura del horno.

ADVERTENCIA La moldura permite la entrada del aire al gabinete bajo la unidad y no debe ser obstruida.

INSTALACIN DEL HORNO (Cont.)

8 31-2000792 Rev. 0

Instrucciones de Instalacin

1 AJUSTE EL REGULADOR DE PRESIN DE GAS NATURAL A GAS LP(Cont.)

D. Saque el retenedor de la tapa. E. Invierta el retenedor de manera que LP se vea sobre el

fondo del retenedor. F. Coloque nuevamente el retenedor dentro de la tapa. G. Coloque nuevamente la tapa sobre el regulador. H. Reemplace la Placa Protectora del Regulador usando los

2 tornillos que la sostenan originalmente.

1 AJUSTE EL REGULADOR DE PRESIN DE GAS NATURAL A GAS LP

A. Retire la Placa Protectora del Regulador desde la parte trasera del rea del cajn de almacenamiento, retirando los 2 tornillos.

B. Ubique el regulador.

C. Destornille la tapa.

CMO HACER LA CONVERSIN PARA GAS LP

ADVERTENCIA Si usted va a usar gas LP (embotellado), todos los ajustes descritos ms abajo deben hacer antes de hacer cualquier ajuste a los quemadores o usar el horno.

ADVERTENCIA Esta conversin debe ser hecha por un instalador competente o por el abastecedor de gas de acuerdo con las instrucciones del fabricante y todos los cdigos y requerimientos de las autoridades que tienen jurisdiccin. El no seguir las instrucciones podra resultar en serias heridas o dao a la propiedad. La agencia calificada que hace este trabajo asume la responsabilidad de la conversin. NOTA: Desconecte toda la electricidad y cierre el paso del gas en la vlvula de cierre antes de empezar la conversin.

NAT. l..P.

Tapa Sello

Sujetado de Resorte

LP Nat

Fig. 12

2 CMO AJUSTAR EL ORIFICIO DEL QUEMADOR DE GAS NATURAL A GAS LP

PRECAUCIN Los ajustes en la siguiente columna se deben hacer antes de encender los quemadores. Si no se hace de esa manera podran resultar heridas serias debido a llamas altas y vapores txicos. Su quemador para asar a la parrilla est localizado en la porcin superior de su horno y el acceso a ste es fcil. Para lograr acceso a su quemador para hornear siga las instrucciones ms adelante: A. Abra la puerta del horno. B. Saque el fondo del horno. C. Saque los 4 tornillos que sujetan el esparcidor de llamas.

D. Saque la cubierta del orificio.

Esparcidor del quemador fondo del horno

Fig. 13

Obturador de Aire Cubierta

del Orificio

Tornillo del Obturador de Aire Fig. 14

INSTALACIN FLEXIBLE

Regulador de Presin con

Vlvula de Cierre Incorporada

Adaptador Conexin Flexible

Placa de Cubierta del Regulador

Fig. 11

31-2000792 Rev. 0 9

Instrucciones de Instalacin

3 PARA QUEMADORES PARA HORNEAR Y ASAR

la tapa del orificio en direccin de LP, aprox. 1 1/2 vuelta, hasta que quede apretada.

IMPORTANTE: No apriete demasiado o podra doblar la tapa del orificio o la aguja.

5 AJUSTE EL OBTURADOR DE AIRE

NOTA: Las llamas para hornear y asar se deberan revisar con la puerta cerrada para revisar correctamente las caractersticas de la llama. Encienda el quemador para hornear o para asar. Mientras mira la llama con la puerta cerrada, revise lo siguiente a travs de la ventana de la puerta: A. Las llamas del quemador no deberan pestaear o soplar

en direccin opuesta al quemador. B. Deberan ser de color azul sin muestras de amarillo. C.

EN ALGUNOS CASOS A. Con el gas LP, un poco de amarillo en las puntas es

normal. B. Partculas extraas en la lnea del gas podran causar

una llama anaranjada al principio, pero esto desaparecer pronto.

4 CMO REVISAR EL TAMAO DE LA LLAMA

Revise el cono interior de la llama. Debera ser de aprox.

quemadores para hornear y para asar. Si el tamao de la llama est para alargar, use una llave

ajustable para ajustar la tapa del orificio, hacindola girar hacia LP

ADVERTENCIA Si trata de medir el cono interior de la llama, por favor use precaucin; se podra quemar.

CMO HACER LA CONVERSIN PARA GAS LP (Cont.)

NAT.

NAT.

Ajustes de Gas NAT. LP Hechos a la Tapa del Orificio

LP

LP

Obturador de Aire

Obturador de Aire

Tornillo del Obturador de Aire

Fig. 15

Fig. 16

Quemador para hornear

Quemador para asar

1/2 a 3/4

Cono Interior de la Llama

Fig. 17

A Llamas Amarillas

Llame para un Servicio

B Puntas Amarillas

Normal para Gas LP

C Llamas de Azul Suave

Normal para Gas Natural

Fig. 18

10 31-2000792 Rev. 0

Instrucciones de Instalacin

5 AJUSTE EL OBTURADOR DE AIRE (Cont.)

QUEMADOR PARA HORNEAR

A. Use un destornillador para soltar el tornillo del obturador. 1. Si las llamas estaban amarillas, abra el obturador de

aire ms que la posicin original. 2. Si las llamas soplaban en direccin opuesta al

quemador, cierre el obturador de aire ms que la posicin original.

B. Haga el ajuste. C. Apriete nuevamente el tornillo del obturador. D. Cierre la puerta del horno y revise nuevamente la llama. E. Cuando todos los ajustes sean hechos y los resultados

son satisfactorios: 1. Coloque nuevamente cubierta del orificio. 2. Ponga en su lugar el esparcidor de llamas. 3. Coloque el fondo del horno nuevamente en su lugar.

5 AJUSTE EL OBTURADOR DE AIRE (Cont.)

QUEMADOR PARA ASAR A. El quemador para asar est ubicado y es accesible en la

parte superior trasera del horno. B. Use un destornillador para soltar el tornillo del ajuste del obturador de aire.

1. Controle el obturador de aire para asegurar que se encuentre en la posicin completamente abierta y libre de cualquier obstruccin. Para la aplicacin NG, asegrese de que el regulador se encuentre en la posicin NG. Para las aplicaciones de LP, asegrese de que la campana se haya ajustado en la posicin LP.

2. Si las llamas soplaban en direccin opuesta al quemador, cierre el obturador de aire ms que la posicin original.

C. Haga el ajuste. D. Apriete nuevamente el tornillo del obturador. E. Cierre la puerta del horno y revise nuevamente la llama.

NOTA ESPECIAL: Para convertir el horno de vuelta a gas natural, invierta las instrucciones dadas para hacer los ajustes para gas LP

ADVERTENCIA Una vez que la conversin est terminada y funcionando bien, llene la etiqueta de LP localizada en el paquete enviado con su estufa e incluya su nombre, organizacin y la fecha en que la conversin fue hecha. Pegue la etiqueta al marco frontal de la estufa cerca de la placa de identificacin detrs del cajn y advierta a otros en el futuro que esta estufa ha sido convertida para ser usada con gas LP. Si se convierte de vuelta de gas LP a gas natural, por favor saque la etiqueta para que otros sepan que la estufa est programada para ser usada con gas natural.

CMO HACER LA CONVERSIN PARA GAS LP (Cont.)

Obturador de Aire Cubierta

d

Manualsnet FAQs

If you want to find out how the JGRP20 GE works, you can view and download the GE JGRP20 JGRP20WEJWW Oven Installation Instructions on the Manualsnet website.

Yes, we have the Installation Instructions for GE JGRP20 as well as other GE manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Installation Instructions should include all the details that are needed to use a GE JGRP20. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the GE JGRP20 JGRP20WEJWW Oven Installation Instructions is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This GE JGRP20 JGRP20WEJWW Oven Installation Instructions consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download GE JGRP20 JGRP20WEJWW Oven Installation Instructions free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print GE JGRP20 JGRP20WEJWW Oven Installation Instructions, simply download the document to your computer. Once downloaded, open the PDF file and print the GE JGRP20 JGRP20WEJWW Oven Installation Instructions as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.