- Manuals
- Brands
- GE
- Dryer
- DSKS333ECWW
- Installation Instructions
GE DSKS333 DSKS333ECWW Dryer Installation Instructions PDF
Summary of Content for GE DSKS333 DSKS333ECWW Dryer Installation Instructions PDF
MATERIALS YOU WILL NEED
- Risk of Fire To reduce the risk of severe injury or death, follow all
installation instructions.
installer. Install the clothes dryer according to these instructions
and in accordance with local codes. In the absence of local codes, installation must comply with the NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70.
This dryer must be exhausted to the outdoors. Use only 4 rigid metal ducting for exhausting the clothes
dryer to the outdoors.
installed, it must be UL listed and installed in accordance with the instructions found in Connecting The Dryer To House Vent on page 4 of this manual. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions
Do not install or store this appliance in any location where it could be exposed to water and or weather.
DETERMINE ELECTRICAL REQUIREMENTS FOR YOUR DRYER MODEL
The electrical installation must conform to the national and local codes. 208V AND 240V MODELS ARE NOT APPROVED FOR 120V INSTALLATION.
Installation Instructions (USA only) MODELS DSKS433 & DSKS333 MUST BE INSTALLED WITH CONTROL PANEL AT BOTTOM TO OPERATE ADEQUATELY.
UNPACKING AND PREPARING FOR INSTALLATION Prepare the area and exhaust for installation of new dryer.
Remove the literature and accessories bag from the dryer drum. Place the literature in a convenient place. Using foam pads from dryer carton, turn dryer upside down as shown. Install knobs. For location, refer to the Owners Manual. Dryer is now ready to be mounted above washer using accessory kit. Remove the foam shipping pads from under dryer. Move the dryer to the desired location. Follow the steps in the following pages to connect the dryer to the external exhaust and power supply.
BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT- Save these instructions for local
inspectors use. IMPORTANT- Observe all governing codes
and ordinances. Note to Installer -
instructions with the customer. Note to Customer - Keep these instructions with
your Owners Manual for future reference.
discarded, remove the dryer door. Service information and the wiring diagram are
located in the control console. Do not allow children on or in the appliance. Close
supervision of children is necessary when the appliance is used near children.
Install the dryer where the temperature is above
system. Product failure due to improper installation is not
covered under the Warranty.
TOOLS YOU WILL NEED
SLIP JOINT PLIERS FLAT BLADE AND PHILLIPS SCREWDRIVERS
GLOVES
SAFETY GLASSES
DRYER POWER CORD KIT
(NOT PROVIDED WITH DRYER)
4" DUCT CLAMPS (2)
OR 4" SPRING
CLAMPS (2)
EXHAUST HOOD
3/4" STRAIN RELIEF UL RECOGNIZED4" DIA. METAL
ELBOW
4" DIA. FLEXIBLE METAL (SEMI-RIGID) UL LISTED TRANSITION DUCT (IF NEEDED) KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT (RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE) UL LISTED TRANSITION DUCT (IF NEEDED.) DUCT TAPE
UL RATED 120/240V,30A WITH 3 OR 4 PRONGS. IDENTIFY THE PLUG TYPE AS PER THE HOUSE RECEPTACLE BEFORE PURCHASING LINE CORD.
31-3000326 03-22 GEA
STACKING KITS FOR DRYERS (Comes with individual Installation Instructions)
Over washer - Use Wall Mount Kit WMK-35 or - Stack Rack DSDR24 or - Stack Rack DSR-24 For alcove and closet depth and width
All stacking kits are available from your local sales outlet.
Questions? Call: 800.GE.CARES (US) or visit our web site at: www.GEAppliances.com (US)
Printed in Mexico
WARNING
FOR THREE-WIRE SUPPLY (208V & 240V MODELS)
Remove terminal block cover.
of terminal block. Connect Neutral line to center
Properly strain relief the cordset or cable to the cable entry hole with UL recognized strain relief. Replace terminal block cover.
FOR FOUR-WIRE SUPPLY (208V & 240V MODELS)
Remove terminal block cover.
grounding screw in place.
of terminal block.
Attach ground wire of power supply to green grounding screw beside terminal block.
Properly strain relief the cordset or cable to the cable entry hole with UL recognized strain relief. Replace terminal block cover.
Typical 30 amp receptacle for use where local codes permit use of flexible type power supply cord (pigtail).
3 WIRE RECEPTACLE (10-30R)
Rating Plate located to the right of the loading port. Connect this dryer to a circuit corresponding to that
indicated on Rating Plate and protected by fuses or a circuit breaker in accordance with local codes.
Use a power supply cord kit marked for use with
supply cord kit marked for use with clothes dryers.
Connect supply wire leads to terminal block as shown on sketch below, depending on type of installation.
Make sure screws on terminal block are tight.
This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electrical current.
WARNING Improper connection of the equipment grounding conductor can result in a risk
serviceman if you are in doubt as to whether the appliance is properly grounded.
WARNING Appliance grounded to neutral conductor through a link. If used in a mobile home,
a new construction, a recreational vehicle or if local codes do
cable assembly for use with clothes dryers must be used with
UL recognized strain relief. See manufacturers instructions.
ELECTRICAL CONNECTION DETAILS OBSERVE ALL GOVERNING CODES AND ORDINANCES
DO NOT USE EXTENSION CORD WITH THIS APPLIANCE
GROUNDING INSTRUCTIONS
POWER SUPPLY
MINIMUM COPPER
LOOP TERMINALS
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
POWER SUPPLY
COPPER CONDUCTORS
WITH TYPE UL
MINIMUM RATED
OPERATION
Hot Wire
Screw
Strap
White Neutral Wire
Hot Wire
Hot Wire
White Neutral Wire
Hot Wire
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
Typical 30 amp receptacle for use where local codes permit use of
flexible type power supply cord (pigtail).
Typical 30 amp cord assembly for use where local codes do not
permit grounding through neutral.
4-WIRE RECEPTACLE (14-30R) 4-CONDUCTOR CORD
ASSEMBLY (Type ST Cable)
X
W G
Y
IF YOUR DRYER COMES WITH REAR EXHAUST, TO CHANGE TO SIDE OR BOTTOM EXHAUST: Remove access panel at back of dryer to gain access
to internal ducts. Disconnect duct exhaust from blower housing
FOR SIDE EXHAUST:
Attach this extension duct to blower housing duct.
to protrude through side of cabinet. Seal all joints with duct tape. Reinstall rear access panel. FOR BOTTOM EXHAUST: Remove cover plate at bottom of dryer.
Seal all joints with duct tape. Reinstall rear access panel.
IF YOUR DRYER COMES WITH TOP EXHAUST, TO CHANGE TO SIDE OR REAR EXHAUST: Remove rear access panel.
mounting screw from the chassis and remove tape securing elbow to blower housing.
Remove cover plate from rear access panel and place over top exhaust opening.
FOR SIDE EXHAUST:
Attach this extension duct to blower housing duct.
to protrude through side of cabinet. Seal all joints with duct tape. Reinstall rear access panel. FOR REAR EXHAUST:
Attach this extension duct to blower housing. Seal all joints with duct tape. Reinstall rear access panel.
EXHAUST INFORMATION WARNING IN CANADA AND IN THE UNITED
STATES, THE REQUIRED EXHAUST DUCT DIAMETER IS 4 in (102mm). DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EXHAUST LENGTH TABLE.
Increase the drying times and the energy cost. Reduce the dryer life.
WARNING BEFORE PERFORMING THIS EXHAUST INSTALLATION, BE
SURE TO DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY. The correct exhaust installation is YOUR RESPONSIBILITY. Problems due to incorrect installation are not covered by the warranty. Remove and discard existing plastic or metal foil transition duct
The MAXIMUM ALLOWABLE duct length and number of bends of the exhaust system depends upon the type of duct, number
noted below. The maximum duct length for rigid metal duct is shown in the table on the next page.
EXHAUST SYSTEM CHECK LIST HOOD OR WALL CAP Terminate in a manner to prevent back drafts or entry of birds or other wildlife.
Termination should present minimal resistance to the exhaust air
Never install a screen in or over the exhaust duct. This could cause lint build up.
other obstruction with the opening pointed down.
SEPARATION OF TURNS For best performance, separate all turns by at least 4 ft. of straight duct, including distance between last turn and exhaust hood. TURNS OTHER THAN 90
SEALING OF JOINTS All joints should be tight to avoid leaks. The male end of each
section of duct must point away from the dryer. The duct shall not be assembled with screws or other fastening
means that extend into the duct and catch lint.
overlapped joints with duct tape. Horizontal runs should slope down toward the outdoors
inch per foot. INSULATION Ductwork that runs through an unheated area or is near air conditioning
EXHAUST CONNECTION WARNING TO REDUCE THE RISK OF FIRE
OR PERSONAL INJURY: This clothes dryer must be exhausted to the outdoors. Use only 4 rigid metal ducting for the home exhaust duct.
It must be installed in accordance with the instructions found in Connecting the Dryer to House Vent on page 4 of this manual.
Do not terminate exhaust in a chimney, a wall, a ceiling, gas
other concealed space of a building. The accumulated lint
Never terminate the exhaust into a common duct with a kitchen exhaust system. A combination of grease and lint creates a
table. Longer ducts can accumulate lint, creating a potential
Never install a screen in or over the exhaust duct. This will
Do not assemble ductwork with any fasteners that extend into the duct. These fasteners can accumulate lint, creating a
Do not obstruct incoming or exhausted air. Provide an access for inspection and cleaning of the exhaust
system, especially at turns and joints. Exhaust system shall be inspected and cleaned at least once a year.
ALTERNATE EXHAUST INSTRUCTIONS DRYER TOP VIEW
Left knockout
Bottom knockout
Right knockout
Blower
Fr on
t o f d
ry er
152 mm
203 mm (8)
89 mm (3)
6
For Rear Exhaust
For Side Exhaust
Rigid Metallic DuctingCut Here
EXTENSION DUCT
It is importat to replace the ground clip after cutting the exhaust duct, (on rear exhaust model)
295 mm
115 mm (4)
(11)
EXHAUST LENGTH CALCULATION RIGID (Preferred)
4
ALCOVE OR CLOSET INSTALLATION If your dryer is approved for installation in an alcove or
closet, it will be stated on a label on the dryer back. The
WARNING TO PREVENT LARGE AMOUNTS OF LINT AND
MOISTURE FROM ACCUMULATING AND TO MAINTAIN DRYER EFFICIENCY, THIS MACHINE MUST BE EXHAUSTED OUTDOORS.
Minimum clearances between dryer cabinet and
Closet doors must be louvered or otherwise ventilated
equally distributed. If the closet contains both a washer
of open area equally distributed.
NOTE TO INSTALLER - AFTER INSTALLATION CHECK THE FOLLOWING:
to local codes and ordinance requirements.
4" DIA.
4"
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types
Recommended
No. of 90 Elbows
Rigid Metal
Rigid Metal
14 m (46 ft) 11 m (37 ft) 9 m (30 ft) 7 m (23 ft)
11 m (37 ft) 9 m (30 ft)
6.5 m (22 ft) 4.5 m (15 ft)
0 1 2 3
Use only for short run installations
CONNECTING THE DRYER TO HOUSE VENT RIGID METAL TRANSITION DUCT For best drying performance, a rigid metal transition duct
is recommended. Rigid metal transition ducts reduce the risk of crushing
and kinking. UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION DUCT
other enclosed spaces.
feet. For many applications, installing elbows at both the dryer
without kinking and or crushing the transition duct, maximizing drying performance.
Avoid resting the duct on sharp objects.
UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT In special installations, it may be necessary to connect the
diameter can be maintained throughout the entire length of the transition duct.
other enclosed spaces.
Avoid resting the duct on sharp objects. For best drying performance
4. Secure the duct to the exhaust pipe with the other clamp.
NOTE: The clearances stated above are minimums. Consideration must be given to the type accessory
instruction for details.
Alcove Closet Sides 0 Top Front Rear
WHEN INSTALLED IN MANUFACTURED (MOBILE) HOMES Dryer must be exhausted to the outside. Exhaust MUST NOT be terminated beneath mobile home. Exhaust material MUST NOT support combustion. Installation MUST conform to Manufactured
or when such standard is not applicable, the Ameri
Related manuals for GE DSKS333 DSKS333ECWW Dryer Installation Instructions
Manualsnet FAQs
If you want to find out how the DSKS333ECWW GE works, you can view and download the GE DSKS333 DSKS333ECWW Dryer Installation Instructions on the Manualsnet website.
Yes, we have the Installation Instructions for GE DSKS333ECWW as well as other GE manuals. All you need to do is to use our search bar and find the user manual that you are looking for.
The Installation Instructions should include all the details that are needed to use a GE DSKS333ECWW. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.
The best way to navigate the GE DSKS333 DSKS333ECWW Dryer Installation Instructions is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.
This GE DSKS333 DSKS333ECWW Dryer Installation Instructions consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.
You can download GE DSKS333 DSKS333ECWW Dryer Installation Instructions free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.
To be able to print GE DSKS333 DSKS333ECWW Dryer Installation Instructions, simply download the document to your computer. Once downloaded, open the PDF file and print the GE DSKS333 DSKS333ECWW Dryer Installation Instructions as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.