USA 1-800-944-9044 www.frigidaire.com

Canada 1-800-265-8352 www.frigidaire.ca

LI30KC / 316902495 May/13

Thank you for choosing Frigidaire.

This Use & Care Guide is part of our commitment to customer satisfaction and product quality throughout the service life of your new appliance.We view your purchase as the beginning of a relationship. To ensure our ability to continue serving you, please use this page to record important product information.

Need help??

Visit the Frigidaire web site at www.frigidaire.com Before you call for service, there are a few things you can do to help us serve your better.

Read this Use & Care manual. It contains instructions to help you use and maintain your range properly.

If you received a damaged range Hood... immediately contact the dealer (or builder) that sold you the range hood.

Save time and money. Check the Troubleshooting list. This section helps step you through some common problems that might occur. If you do need service, help is only a phone call away. Call Frigidaire Customer Services at 1-800-944-9044.

Product Registration Registering your product with Frigidaire enhances our ability to serve you. You can register online at www.frigidaire.com or by dropping your Product Registration Card in the mail.

Serial Plate Location

Serial plate location: Find it on the left side of the range hood.

Record model & serial numbers here

Purchase date

Model number

Serial number

PRODUCT RECORD AND REGISTRATION

CONTENTS Important Safety Instructions ............................... 3 List of materials ................................................... 5 Electrical requirements ......................................... 5 Location requirements .......................................... 6 Product dimensions .............................................. 6 Venting Requirements .......................................... 7 Prepare the location ............................................. 8 Install Range Hood (Ducted version) ..................... 10 Make Electrical Connection .................................... 12 Installing Range Hood (Recirculating version) ......... 10 Range Hood Use .................................................. 13 Range Hood Care ................................................. 14 Troubleshooting ................................................... 15 Warranty Information ........................................... 16

Be sure to visit us online at www.frigidaire.com

for a complete line of accessories.

Save these instructions for future references

Approved for residential appliances

For residential use only

Do not attempt to install or operate your appliance until you have read the safety precautions in this manual. Safety items throughout this manual are labeled with a WARNING or CAUTION based on the risk type.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety mes- sages that follow this symbol to avoid possible injury or death.

WARNING

This symbol alerts you to situations that may cause serious body harm, death or property damage.

CAUTION

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

IMPORTANT IMPORTANT indicates installation, operation, maintenance or valuable information that is not hazard related.

IMPORTANT SAFETY INSTRUCTIONS

CAUTION

FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPORS.

IMPORTANT SAFETY INSTRUCTIONS

Read all instructions before using this appliance.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer

Before servicing or cleaning the unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

Installation Work and Electrical Wiring Must Be Done ByQualifiedPerson(s)InAccordanceWithall Aplicable Codes & Standards, Including Fire-rated Construction. Sufficientairisneededforpropercombustionandex

haustingofgasesthroughtheflue(Chimney)offuel burning equipment to prevent back- drafting. Follow the heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Ducted systems must always be vented to the outdoors.

A.

B.

C.

D.

E.

F.

CAUTION

To reduce risk of fire and to properly exhaust air, be sure to duct air outside - do not vent ex- haust air into spaces within walls, ceilings, attics, crawl spaces, or garages.

WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK. Install this hood in accordance with all requirements specified.

4

WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS, IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:

SMOTHER FLAMES withaclose-fittinglid,cookie sheet, or other metal tray, then turn off the gas burner or the electric element. BE CAREFUL TO PREVENT BURNS.Iftheflamesdo not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

NEVER PICK UP A FLAMING PAN - you may be burned.

DO NOT USE WATER, including wet dishcloths or towels-aviolentsteamexplosionwillresult. UseanextinguisherONLY if: YouknowyouhaveaclassABCextinguisher, and you already know how to operate it. Thefireissmallandcontainedinthearea where it started. Thefiredepartmentisbeingcalled. Youcanfightthefirewithyourbacktoanexit.

OPERATION Alwaysleavesafetygrillsandfiltersinplace.Without these components, operating blowers could catch onto hair,fingersandlooseclothing. The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,maintenance and suitable use of the product. The manufacturer further declines all respon- sibility for injury due to negligence and the warranty of theunitautomaticallyexpiresduetoimpropermainte- nance.

a)

b)

c)

d) 1)

2)

3) 4)

IMPORTANT SAFETY INSTRUCTIONS

WARNING

To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Hood With Any External Solid State Speed Control Device.

WARNING

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE.

Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

Always turn hood ON when cooking at high heat or whenflambeingfood(l.e.CrepesSuzette,Cherries Jubilee, Peppercorn Beef Flambe).

Clean ventilating fans frequently. Grease should not beallowedtoaccumulateonfanorfilter.

Use proper pan size. Always use cookware appropriate for the size of the surface element.

a)

b)

c)

d)

LIST OF MATERIALS

LIST OF MATERIALS

Parts included in your hood 4-0.45x1.3cmmountingscrews 3x10(8.3x25.4cm)rectangularmetalvent

system. NOTE: An optional 7 round duct kit is available. You can order this kit as part number 5304487139.

Parts Needed 2 - UL listed wire connectors 1-75Wmax,120Vincandescentlightbulb Wall or roof cap with damper to match vent system Vent clamps/duct tape as required UL listed or CSA approved strain relief

Tools/Materials required

Drill 1 (3.0 cm) drill bit (0.3cm)drillbitforpilotholes Pencil Wire stripper or utility knife Tape measure or ruler Caulking gun and weatherproof

caulking compound Flat-blade screwdriver Phillips screwdriver Saber or keyhole saw

For cabinets with recessed bottoms: Two2(5.1cm)widefillerstrips.Lengthand

thickness determined by recess dimensions. Fourflatheadwoodscrewsormachinescrews

withwashersandnuts(toattachfillerstrips).

ELECTRICAL REQUIREMENTS Observe all governing codes and ordinances. Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edi- tion) and all local codes and ordinances. If codes permit and a separate ground wire is used, it is recommendedthataqualifiedelectriciandeterminethat the ground path is adequate. A copy of the above code standards can be obtained from:

National Fire Protection Association One Batterymarch Park

Quincy, MA 02269 CSA International

8501 East Pleasant Valley Road Cleveland, OH 44131-5575

A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.

If the house has aluminum wiring, follow the procedure below:

Connect a section of solid copper wire to the pigtail leads.

Connect the aluminum wiring to the added section of copper wire using special co nectors and/or tools designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturers recom- mended procedure. Aluminum/copper connection must conform with local codes and industry accepted wiring practices.

Wire sizes and connections must conform with theratingoftheapplianceasspecifiedonthe model/serial rating plate. The model/serial plate is located on the left side of the range hood.

Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 (la est edition), or CSA Standards C22. 1-94, Canad an Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.

1.

.

IMPORTANT Observe all governing codes and ordinances.

It is the installers responsibility to comply with installationclearancesspecifiedonthemodel/serial rating plate. The model/serial rating plate is located inside the range hood on the left side (See page 2 for location). Range hood location should be away from strong draft areas, such as windows, doors and strong heating vents.

Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance. Consult the cooktop/range manufacturer installation instructions before making any cutouts.

Grounded electrical outlet is required. See Electrical Requirements section.

All openings in ceiling and wall where canopy hood will be installed must be sealed.

For Mobile Home Installations The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or when such standard is not applicable, the stan- dard for Manufactured Home Installation 1982 (Manu- factured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local codes.

Cabinet Dimensions

A. 66 (167 cm) suggested min. - top of range hood to floor. B. 30 (76.2 cm) min. cabinet opening width for 30 (76.2 cm) models and 36 (91.4 cm) min. cabinet width for 36 (91.4 cm) models. C. 13 (33.0 cm) cabinet depth D. 36 (91.4 cm) base cabinet height

LOCATION REQUIREMENTS

PRODUCT DIMENSIONS

A

B

C

D

hood model Dim A Dim B

FHWC3025 30 models

30 (76.2 cm) 69/16 (16.7 cm)

FHWC3625 36 models

36 (91.44 cm) 9 (24.3 cm)

DIM B

DIM A

3 (8.25cm)

10 (25.4cm

9 (24cm) recirculating cover

1 (4cm) recirculating cover

)

10 (25.4cm)

7 (17.8cm

9/16(1.4cm)

) 1 (2.5cm) typical both sides

9 (22.9cm) typical both sides

185/8 (47.3cm)

7/8 (2.2cm)

7/8 (2.2cm)

415/16 (12.5cm)

1 (3.8cm) typical both sides

Vent system must terminate to the outdoors. Do not terminate the vent system into an attic or other

enclosed area. Do not use a 4 (10.2 cm) laundry-type wall cap. Use a 3x10(8.3x25.4cm)rectangularmetal

vent. Rigid metal vent is recommended. Plastic or metal foil vent is not recommended.

The length of vent system and number of elbows shouldbekepttoaminimumtoprovideefficient performance.

Forthemostefficientandquietoperation: Use no more than three 90 elbows. Make sure there is a minimum of 24 (61 cm) of straight

vent between the elbows if more than 1 elbow is used. Do not install 2 elbows together. Use clamps or duct tape to seal all joints in the

vent system. Theventsystematexitmusthaveacoldairdamper. Usecaulkingtosealexteriorwallorroofopening

around the cap. Best performances are reached with straight piping,

without elbows and using smooth pipe. Maximumrecomendedventsystemlength:35ft(10.7m).

Cold Weather Installations An additional back draft damper should be installed to minimizebackwardcoldairflowandathermalbreak should be installed to minimize conduction of outside tem- peratures as part of the vent system. The damper should be on the cold air side of the thermal break. The break should be as close as possible to where the vent system enters the heated portion of the house. Makeup Air Local building codes may require the use of makeup air systems when using ventilation systems greater than specifiedCFMofairmovement.ThespecifiedCFMvaries from locale to locale. Consult your HVAC professional for specificrequirementsinyourarea. Venting Methods Vent system can terminate either through the roof or wall. Use 3x10(8.3x25.4cm)rectangularwithamaximum vent length of 35 ft (10.7 m) or 7 (17.8 cm) round vent with amaximumlengthof50ft(15.2m)forventsystem.

NOTE

Flexible vent is not recommended. Flexible vent creates both back pressure and air turbulence that greatly reduce performance.

Calculating Vent System Length To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system. (1.8 cm) Round Vent System

Vent Piece

90 elbow 5.0 ft (1.5 m)

7 (17.8 cm) wall cap 0.0 ft (0.0 m)

Example Vent System

A

B

C

A B

C

A. 3x10(8.3x25.4cm) rectangular vent through the roof. (purchased separately) B. Roof cap with damper (purchased separately) C. 24 (61.0 cm) min. to 30 (76.2cm) above the cooking surface

A. 3x10(8.3x25.4cm) rectangular vent through the wall or out the top (purchased separately) B. Wall cap with damper (purchased separately) C. 24 (61.0 cm) min. to 30 (76.2cm) above the cooking surface

Roof Venting Wall Venting

MaximumRecommendedLength =50ft(15.2m)

1-90elbow =5.0ft(1.5m) 8ft(2.4m)straight =8.0ft(2.4m) 1-wallcap =0.0ft(0.0m)

Lengthof7(17.8cm)system =13.0ft(3.9m)

2 ft (0.6 m)

7 (17.8 cm) round 90 elbow

6 ft (1.8 m) Wall Cap

VENTING REQUIREMENTS

8

PREPARE THE LOCATION

NOTE

Before making cutouts, make sure there is proper clearance within the ceiling or wall.

Disconnect power. Selectaflatsurfaceforassemblingtherangehood.

Place covering over that surface. Lift the range hood and set it upside down onto covered

surface. Ifcabinethasrecessedbottom,addwoodfillerstrips

oneachside.Installscrewstoattachfillerstripsin locations shown.

Determine Wiring Hole Location

Determine and clearly mark a vertical centerline on the wall and cabinet bottom.

1. .

.

4.

1.

A

A Centerline

Wood filler strips (recessed cabinet bottoms only)

Wall

Cabinet bottom

3 (7.6 cm)

3 (7.6 cm)

4.5x13mm mounting screws

VENTING REQUIREMENTS

x 10 (8.3 cm x 25.4 cm) Vent System

Vent Piece

3x10(8.3cmx25.4cm) 5.0ft 90 elbow (1.5 m)

3x10(8.3cmx25.4cm) 12.0ft flat elbow (3.7 m)

3x10(8.3cmx25.4cm) 0.0ft wall cap (0.0 m)

Example Vent System

MaximumRecommendedLength =35ft(10.7m)

1-90elbow =5.0ft(1.5m) 8ft(2.4m)straight =8.0ft(2.4m) 1-wallcap =0.0ft(0.0m)

Length of 3x10 =13.0ft(3.9m) (8.3cmx25.4cm)system

2 ft (0.6 m)

3x10 (8.3x25.4cm)

elbow 6 ft (1.8 m) Wall Cap

9

To wire through top: Mark a line distance (A) from the right of the

centerline on the underside of the cabinet. Mark the point on this line that is 78 (2.2 cm) from back wall. Drill a 1 (3.2 cm) diameter hole (B) through the cab net at this point.

To wire through wall: Mark a line distance (A) from the right of the

centerline on the underside of the wall. Mark the point on this line that is 78 (2.2 cm) from the underside of the cabinet. Drill a 1 (3.2 cm) diameter hole (B) through the rear wall at this point. VENTING Chooseventingexhaustdischargefromthevarious options listed - Style 1 - 4 that follows: Style 1 - Recirculating Hood version For this installation, go to Install Range Hood (recirculating version) on page 11.

.

1.

A

Centerline

78 (2.2 cm) from wall, not cabinet frame

B

A

A Centerline

78 (2.2 cm)

B

Style 2 - Cut Openings for 3 x 10 (8.3 cm x .4 cm) Rectangular Vent System

Roof Venting Tomakea4x10(10.16cmx26.7cm)rectangular cutout on the underside of cabinet top and bottom:

Mark lines (1.3 cm) and 4 (12.1 cm) from the back wall on the centerline of the underside of cabinet.

Mark lines 5 (13.3 cm) to the right and left of the centerline on the underside of cabinet.

Use saber or keyhole saw to cut a rectangular opening for vent.

Repeat steps 1-3 for the underside of the top of the cabinet.

Wall Venting Tomakea3x10(8.9cmx26.7cm)rectanglein the wall:

Make 2 lines by measuring 38 (0.9 cm) and 378 (9.8 cm) down from underside of cabinet and mark on the centerline on the back wall.

Mark lines 5 (13.3 cm) to the right and left of the centerline on the wall.

Use saber or keyhole saw to cut a rectangular opening in the wall for the vent.

1.

.

.

4.

1.

.

.

Cabinet cutouts

*From wall, not cabinet frame

*1/2 (1.3 cm)

51/4 (13.3 cm)

51/4 (13.3 cm)

*43/4 (12.1 cm)

Cabinet front

Centerline

51/4 (13.3 cm)

37/8 (9.8 cm)

3/8 (0.9 cm)

51/4 (13.3 cm)

Centerline

PREPARE THE LOCATION

hood model

Dim A

30 & 36 models

88 (21.3 cm)

hood model

Dim A

30 & 36 models

88 (21.3 cm)

10

Install Vent System Install vent through the vent opening in upper cabinet

or wall. Complete venting system according to the selected venting method. See Venting Requirements section. Usecaulkingtosealexteriorwallorroofopening

around the cap.

INSTALL RANGE HOOD (Ducted version)

NOTE

Your model will have a 3 x 10 (8.3 x 25.4 cm) rectangular vent connector on the inside of the range hood.

Unpackthe3x10(8.3x25.4cm)rectangular vent from the inside of your range hood. To detach the vent connector, remove the 2 installation screws (.35x.95cm)andkeepthescrewsinasafeplaceto reinstall later (see Step 5).

Lift the range hood up under cabinet and determine finallocationbycenteringbeneathcabinet.Markon the underside of cabinet the location of the 4 keyhole mounting slots on the range hood (See slot dimensions on page 6). Set range hood aside on a covered surface.

1.

.

1.

.

A

A. Keyhole slot

A

A

B

A. 3 x 10 (8.3 x 25.4 cm) rectangular vent damper B. 3.5 x 9.5 mm screws

PREPARE THE LOCATION

Style 3 - Cut Openings for 3 x 10 (8.3 x 25.4 cm) Rectangular Vent Transition to Round Vent

Roof Venting To make a circular vent opening on the underside of the cabinet top:

Mark a centerline on the underside of the top of cabinet. Mark a line 5 (12.7 cm) from the back wall on the

underside of the top of cabinet. Use a compass or a circle template to draw a circle with

a diameter of 7 (19 cm). Use saber or keyhole saw to cut the circular vent opening. Style 4 - Cut Openings for (1.8 cm) Round Vent to Round Vent Transition

Roof Venting To make a circular vent opening on the underside of the cabinet top: NOTE: The 7 round transition kit, part number 5304487139, is required for this installation.

Mark a centerline on the underside of the top of cabinet. Mark a line 5 (12.7 cm) from the back wall on the

underside of the top of cabinet. Use a compass or a circle template to draw a circle with

a diameter of 7 (19 cm). Use saber or keyhole saw to cut the circular vent opening.

Repeat steps 1-3 for the underside of the top of the cabinet.

1. .

.

1. .

.

4.

*From wall, not cabinet frame

*5 (12.7 cm)

Cabinet cutouts

7 (19 cm)

Centerline

*From wall, not cabinet frame

*5

*

*

(12.7 cm) Cabinet cutouts

* 7 (19 cm)

Centerline

11

Use8 (3 mm) drill bit and drill 4 pilot holes as shown. NOTE: Make the drill holes on the thin area of the slot.

Installthe4-.45cmx1.3cmmountingscrewsin pilot holes. Leave about (6.4 mm) space between screw heads and cabinet to slide range hood into place.

For roof installations, remove the top rectangular vent knockout. For wall installations, remove the rear rectangular vent knockout.

Installthe3x10(8.3x25.4cm)ventconnector. Attachtorangehoodwiththe.35x.95cmscrews that you previously removed (step 1) and remove tape fromdamperflap.

NOTE

The 3 x 10 (8.3 x 25.4 cm) rectangular vent connector can be installed up to 1 (. cm) on either side of the hood center to accommodate off center ductwork.

If a vent damper is installed with a wall cap with damper, check that they do not interfere with each other.Removetheventconnectordamperflapif they interfere.

.

4.

.

4 (6.4 mm)

A

A. Drill pilot hole

A

BA. Vertical connector B.3.5x9.5mmscrews C. Vent knockouts D. Horizontal connector

Power Supply Cable Installation For direct wire installations, run the home power

supply cable according to the National Electric Code or CSA standards and local codes and ordinances. There must be enough wiring from the fused disconnect (orcircuitbreaker)boxtomaketheconnectioninthe hoodelectricalterminalbox.

NOTE

Do not reconnect power until the installation is complete.

Remove the screw from the terminalboxcover. Removeterminalboxcover and set aside.

Remove the power supply knockout from the top or rear of the vent hood (depending on the incoming location of your home power supply cable) and install a UL listed or CSA approved strain relief.

Using2ormorepeople,liftthehoodintofinalposition. Feed enough electrical wire through the UL listed or CSA approved strain relief to make connections in theterminalbox.Tightenthestrainreliefscrews.

Position the range hood so that the large end of the keyhole slots are over the mounting screws. Then push the hood toward the wall so that the screws are in the neck of the slots. Tighten the mounting screws, making sure the screws are in the narrow neck of slots.

Connect ventwork to hood. Seal joints with vent clamps or duct tape to make secure and airtight.

Check that back draft dampers work properly.

1.

.

.

4.

.

.

.

A

B

A. Terminal box cover B. Screw

A

A. Power supply knockout

INSTALLING THE HOOD

1

INSTALLING THE HOOD

INSTALL RANGE HOOD (Recirculating version)

Lift the range hood up under cabinet and determine finallocationbycenteringbeneathcabinet.Markon the underside of cabinet the location of the 4 keyhole mounting slots on the range hood (See slots dimensions on page 6). Set range hood aside on a covered surface.

Use8 (3 mm) drill bit and drill 4 pilot holes as shown. NOTE: Make the drill holes on the thin area of the slot.

Installthe4-.45cmx1.3cmmountingscrewsin pilot holes. Leave about (6.4 mm) space between screw heads and cabinet to slide range hood into place.

Power Supply Cable Installation For direct wire installations, run the home power

supply cable according to the National Electric Code or CSA standards and local codes and ordinances. There must be enough wiring from the fused disconnect (orcircuitbreaker)boxtomaketheconnectioninthe hoodelectricalterminalbox.

NOTE

Do not reconnect power until the installation is complete.

Remove the screw from the terminalboxcover. Removeterminalboxcover and set aside.

1.

.

.

1.

.

A

A. Keyhole slot

A

4 (6.4 mm)

A

A. Drill pilot hole

A

B

A. Terminal box cover B. Screw

MAKE ELECTRICAL CONNECTION

WARNING

Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock.

1. Disconnect power.

2. Use UL listed wire connectors and connect white wires (A) together. 3. Use UL listed wire connectors and connect black wires (B) together.

WARNING

Fire Hazard Electrically ground the blower. Use copper wire. Connect ground wire to green ground screw in terminal box. Failure to do so can result in death, fire, or electrical shock.

4. Connect green (or bare) ground wire from power supply togreengroundscrewinterminalboxandsecurelytighten. 5.Installterminalboxcover. 6. Installthe75W(max.)Incandescentlightbulb.See Replacing the Incandescent Light Bulb in the Range Hood Care section. 7. Reconnect power. Complete Installation Replacegreasefilterifremoved.SeetheRangeHood

Care section. Check the operation of the range hood fan and light.

See Range Hood Use section. If range hood does not operate, check to see whether a circuit breaker has tripped or a household fuse has blown. Disconnect power and check wiring connections.

NOTE

To get the most efficient use from your new range hood, read the Range Hood Use section.

1.

.

A

B

C D E

F

G A.White wires B. Black wires C. UL listed wire connector D. Green (or bare) ground wire E. Home power supply cable F. UL listed or CSA approved strain relief G. Green ground screw

1

Remove the power supply knockout from the top or rear of the vent hood (depending on the incoming location of your home power supply cable) and install a UL listed or CSA approved strain relief.

Using2ormorepeople,liftthehoodintofinalposition. Feed enough electrical wire through the UL listed or CSA approved strain relief to make connections in theterminalbox.Tightenthestrainreliefscrews.

Position the range hood so that the large end of the keyhole slots are over the mounting screws. Then push the hood toward the wall so that the screws are in the neck of the slots. Tighten the mounting screws, making sure the screws are in the narrow neck of slots.

Recirculation Vent Cover Forinstallationswhicharerecirculatingtheairexhaust, the recirculation vent cover must be removed. Remove the recirculating vent cover by removing the 2 mounting screws with a phillips screwdriver. NOTE: For installations which are venting out the roof or wall, the recirculating vent cover must remain in place. Do not remove as unit will not perform properly.

To complete the installation, go to Make Electrical Connection section on page 11.

.

4.

.

RANGE HOOD USE The range hood is designed to remove smoke, cooking vapors and odors from the cooktop area. For best results, start the hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen. The hood controls are located on the top of the range hood.

Range Hood Controls

Operating the light Push the light switch to the right to turn the light On. Push the light switch to the left to the turn the light Off.

Operating the fan Push the fan switch to the left for Low speed. Push the fan switch to the right for High speed. Push the fan switch to the middle for Off.

A. Incandescent light housing and cover B. Charcoal filter retainer C. Grease filter

A

CB

A. On/Off light switch B. Fan speed switch

A B

woLnO High

RANGE HOOD USE

Part being removed

A

A. Power supply knockout

14

Replacescrewinthefilter retainer. Tocleangreasefilter,soak

thefiltersinhotwaterusing a mild detergent. Rinse well and shake to dry. Or place in upper rack of dishwasher to clean. NOTE: Do not use ammo- nia.Thealuminumonthegreasefilterwillcorrodeand darken. NOTE: You can use either dishwasher or hot detergent solution and rinse in clean water.

NOTE

The grease filter is dishwasher safe. To avoid grease filter damage while cleaning, place filter into the dishwasher top rack for cleaning

Replacing the Incandescent LightBulb

Turn off the range hood and allow the light bulb to cool. Disconnectpower-Turnoffhousebreakeratbreakerbox. Squeeze the plastic lens cover and remove it from the hood. Screw a 75Wmax,120V

incandescent light bulb into socket.

Replace lens cover by squeezing cover and inserting tabs into slots.

Reconnect power. If new light does not operate, make sure the lamp is inserted correctly before calling service. Charcoal / Grease Filter Accesory Kit Forrecirculatingventhood,anoptionalcharcoalfilteris available. You can order this as part number 5304486302. Thecharcoalfilterisnotwashable.Itshouldlastupto6 months with normal use. Replacetheoldcharcoalfilterwithanewcharcoalfilter.

4.

.

1. . . 4.

.

.

A A. Filter screw

RANGE HOOD CARE

A B

A. Light bulb socket B. Lens cover

Cleaning

WARNING

To Reduce The Risk Of Fire Or Electrical shock disconnect from power supply before cleaning.

IMPORTANT Clean the hood and grease filters frequently according to the following instructions. Replace grease filter before operating hood.

IMPORTANT Exterior Surfaces Donotusesoap-filledscouringpads,abrasivecleaners, Cooktop Polishing Creme, steel wool, gritty washcloths or paper towels. To avoid damage to the stainless steel, do not use cleaners that contain chlorine.

Cleaning Method: Use warm water with liquid detergent or all purpose

cleaner and soft cloth to clean outside surfaces. Rinse with clean water and dry with soft, lint-free cloth. Useglasscleanertoremovefingerprints. Forstainlesssteelfinishrubindirectionofgrainto

avoid scratching or damaging the surface. NOTE: Onstainlesssteelfinish,cleanindirectionof stainless steel brush to avoid scratching or damaging the surface.

To clean or replace grease filter: Removescrewfromtheplasticfilterretainerclipwith

phillips screwdriver Turnthefilterretainertoreleasefilter.

Reinstallthefilterbyplacingthebackedgeinthe channelatrearofhood.Pushfilterintoplace,turn thefilterretainertosecurefiltertorangehood.

1.

.

.

A

A. Filter screw

1

TROUBLESHOOTING

Problem Possible Causes Solutions After installation, the unit doesnt work.

1. The power line and the cable locking connector is not connecting properly.

1. Check the power connection with the unit is connected properly.

2. The wires from the switches are disconnected or loose.

2. Make sure the wires on the switches are connected properly.

Light works, but motor is not turning.

1. The motor is defective, possible seized. 1. Change the motor.

2. The thermally protected system detects if the motor is too hot to operate and shuts the motor down.

2. The motor will function properly after the thermally protected system cool down.

4. The motor wire is not connected. 4. Make sure the motor wire is plugged into the molexconnector.

The unit is vibrating.

1. The motor is not secure in place. 1. Tighten the motor in place.

2. Damaged blower wheel. 2. Change the blower.

3. The hood is not secured in place. 3. Check the installation of the hood.

The motor is working, but the lights are not.

1. Defective bulb. 1. Change the bulb.

2. The light bulb is loose. 2. Tighten the light bulb.

3. The wires on the light switch are loose. 3. Make sure the wires on light switch are connected properly.

The hood is not venting out properly.

1. The hood might be hanging to high from the cook top.

1. Adjust the distance between the cook top and the bottom of the hood within 24 (61 cm) and 32 (76.2 cm) range.

2. The wind from the opened windows or opened doors in the surrounding area are affecting the ventilation of the hood.

2. Close all the windows and doors to eliminate theoutsidewindflow.

3. Blockage in the duct opening or duct work. 3. Remove all the blocking from the duct work or duct opening.

4. The direction of duct opening is against the wind.

4. Adjust the duct opening direction.

5. Using the wrong size of ducting. 5. Change the ducting to correct size.

Metalfilteris vibrating.

1.Greasefilterisloose. 1.Makesurefilterretainerstillworks.

2. Filter retainer does not freely move 2.Replacegreasefilter.

1

Warranty

Your appliance is covered by a one year limited warranty. For one year from your original date of purchase, Electrolux will repair or replace any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used, and maintained in accordance with the provided instructions. In addition, the glass cooktop or radiant surface

limited warranty. During the 2nd through 5th years from your original date of purchase, Electrolux will provide a replacement glass cooktop or radiant surface element for your appliance which has proven to be defective in materials or workmanship when such appliance is installed, used, and maintained in accordance with the provided instructions.

Exclusions

This warranty does not cover the following: 1. Products with original serial numbers that have been removed, altered or cannot be readily determined. 2. Product that has been transferred from its original owner to another party or removed outside the USA or Canada. 3. Rust on the interior or exterior of the unit. 4. Products purchased as-is are not covered by this warranty. 5. Products used in a commercial setting. 6. Service calls which do not involve malfunction or defects in materials or workmanship, or for appliances not in

ordinary household use or used other than in accordance with the provided instructions. 7. Service calls to correct the installation of your appliance or to instruct you how to use your appliance. 8. Expenses for making the appliance accessible for servicing, such as removal of trim, cupboards, shelves, etc.,

which are not a part of the appliance when it is shipped from the factory. 9.

handles, or other cosmetic parts. 10.

original date of purchase. 11. Pickup and delivery costs; your appliance is designed to be repaired in the home. 12. Surcharges including, but not limited to, any after hour, weekend, or holiday service calls, tolls, ferry trip charges,

or mileage expense for service calls to remote areas, including the state of Alaska. 13.

14. Damages caused by: services performed by unauthorized service companies; use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies; or external causes such

DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES

CUSTOMERS SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE REPAIR OR REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR. ELECTROLUX SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.

If You Need Service

Keep your receipt, delivery slip, or some other appropriate payment record to establish the warranty period should service be required. If service is performed, it is in your best interest to obtain and keep all receipts. Service under this warranty must be obtained by contacting Electrolux at the addresses or phone numbers below.

This warranty only applies in the USA, Puerto Rico and Canada. In the USA and Puerto Rico, your appliance is warranted by Electrolux Major Appliances North America, a division of Electrolux Home Products, Inc. In Canada, your appliance is warranted by Electrolux Canada Corp. Electrolux authorizes no person to change or add to any obligations under this warranty. Obligations for service and parts under this warranty must be performed

Manualsnet FAQs

If you want to find out how the FHWC3625MS Frigidaire works, you can view and download the Frigidaire FHWC3625MS Owner's Guide on the Manualsnet website.

Yes, we have the Owner's Guide for Frigidaire FHWC3625MS as well as other Frigidaire manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Owner's Guide should include all the details that are needed to use a Frigidaire FHWC3625MS. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Frigidaire FHWC3625MS Owner's Guide is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Frigidaire FHWC3625MS Owner's Guide consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Frigidaire FHWC3625MS Owner's Guide free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Frigidaire FHWC3625MS Owner's Guide, simply download the document to your computer. Once downloaded, open the PDF file and print the Frigidaire FHWC3625MS Owner's Guide as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.