Quick Install Guide ioi SD

TRK-101/TRK-101-P Analytic Encoder PTZ Tracker

A. Connect the Unit

TRK-101 TRK-101-P TRK-101/TRK-101-P

B. Discover the Encoder

The unit's GUI is supported by IE 9 and higher (32-bit) with the ActiveX plug-in on PCs running 64-bit Win XP/7/8/8.1.

B.1. Configuring the encoder on your workstation for the first time

1. Install the CD in the product package or download FLIRs Discovery Network Assistant (DNA) utility from the Support > FLIR Firmware & Software Downloads page at http://www.flir.com/security.

2. Click the DNA icon and run DNA v. 2.1.x.x or above to log into the unit.

3. Attach the unit to the same LAN segment as the computer that is managing the unit. DNA automatically discovers the unit on the network and displays the devices current IP address in the Discover List.

4. Select the unit from DNA's Discover List. 5. From the context menu, or from the

Properties > Device Properties screen, select the unit, select PAL or NTSC, click Change Video Format.

6. Click Update.

B.2.a Managing the encoder with Horizon, Meridian or on a DHCP-enabled network

If the encoder is managed by Horizon configured as a DHCP server, or is on a network with a DHCP server, the encoder automatically receives an IP address. 1. Open DNA. The unit is automatically discovered

on the network. See section B.1 for instructions how to install DNA.

2. Verify that the unit is displayed in the Discover List. The unit status should be displayed as Online and Authenticated.

B.2.b Managing the encoder with Latitude or on a network with static IP configuration

If the encoder is managed by Latitude or is on a network without a DHCP server, you must manually enter its IP address in DNA. 1. Open DNA. The unit is automatically discovered.

See section B.1. 2. If you use non-default credentials:

a. Use DNA to select the unit(s). b. Right-click or click the Login button. c. Enter the encoder's User Name ("admin") and Password ("admin"). d. Click Login.

3. In the DNA Assign IP screen, uncheck Use DHCP, and enter the units IP, Mask and Gateway IP addresses. If the encoder is not authenticated, you must first authenticate it.

4. Click Update.

B.3. Log into the Unit 1. Click the unit in DNAs Discover List.

The Login window opens. 2. Enter the default User Name ("admin")

and Password ("admin"), which are case-sensitive. Then click OK.

3. Click Login in DNA. The units web interface opens.

4. Click the message to install the ActiveX plug-in.

5. Follow the on-screen instructions to install the plug-in.

C. Configure PTZ Settings (TRK-101-P)

1. From the Setup > Camera > Type & Model screen, select Pan/Tilt/Zoom (PTZ).

2. If using an analog camera, set the camera model and communication settings. For more information, see the HTML Edition Units Users Guide.

3. If you are using the CP-4221-301 camera with Latitude VMS, bind the units in Latitude and configure PTZ settings on the Web page. If you are using these cameras without a VMS, select the camera and enter the settings for the IP address, port number, user name, and password in the text boxes.

4. Click Start PTZ Setup to configure PTZ settings. For more information, see the Users Guide. 5. Click Apply to save settings.

D. Auto-Calibrate the Camera

From the navigation bar, select the Settings > Analytics > Depth tab. The web interface opens on the Depth > AUTO screen. Verify that the camera is installed at a height of at least four meters (13 feet) and that the horizon is less than 30% of the Field of View.

1. From the Units drop-down list, select Feet or Meter. 2. Select Set camera height and enter the estimated camera height.

3. Click START. The camera automatically calibrates the depth. Be sure that a person is

walking along the Y (Vertical) axis of the FoV while Auto Calibration is in process.

4. Verify that the horizon, camera height, and human marker settings are correct.

5. Click MANUAL and finish configuring depth settings.

While Auto Calibration is in progress, you can go to steps E (Select Rule) and F (Detect). The Auto Calibration finishes when the progress bar reaches 100%. If you stop the

procedure before it finishes, the analytic process will reset. If you change from Auto to Manual mode, you must wait until the analytic process resets in

order to use Manual mode.

E. Select Rule

From the navigation bar, select Analytic > Rules. A rule for detecting humans or vehicles entering the scene (blue masked area) is defined by default. You can activate rules, modify settings, delete, or add a new rule.

To create a new rule:

1. Click NEW.

2. Select the rule type by clicking the link.

3. Draw on the video scene where you want the detection to take place.

4. Define the attributes for detection from the Basic and Advanced tabs.

5. When finished, click APPLY to save the settings.

F. Detect

1. Select the Live tab. 2. Click ARM. The camera is ready for use.

Analytic performance is optimized only after the auto depth calibration process is completed.

G. Attach to Latitude

1. In Latitude, click Physical View on the sidebar. 2. On the Navigation Tree, click the system name. 3. From the Discovery tab, do the following:

a. Under Cameras and Encoders, select IOimage (Latitude 7) or FLIR (Latitude 8). b. Click Start. The camera details are displayed in the Discovery table. c. If the camera was not discovered, click Discover Unit Manually. d. Enter the cameras IP address and select IOimage (Latitude 7) or FLIR and Auto Detect

(Latitude 8). e. Click O

Manualsnet FAQs

If you want to find out how the ioi SD TRK-101-P Flir works, you can view and download the Flir ioi SD TRK-101-P Tracker Quick Install Guide on the Manualsnet website.

Yes, we have the Quick Install Guide for Flir ioi SD TRK-101-P as well as other Flir manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Quick Install Guide should include all the details that are needed to use a Flir ioi SD TRK-101-P. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Flir ioi SD TRK-101-P Tracker Quick Install Guide is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Flir ioi SD TRK-101-P Tracker Quick Install Guide consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Flir ioi SD TRK-101-P Tracker Quick Install Guide free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Flir ioi SD TRK-101-P Tracker Quick Install Guide, simply download the document to your computer. Once downloaded, open the PDF file and print the Flir ioi SD TRK-101-P Tracker Quick Install Guide as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.