Contents

Flir Pan-Tilt Unit v3.01 Computer Controlled Unit User Manual PDF

1 of 54
1 of 54

Summary of Content for Flir Pan-Tilt Unit v3.01 Computer Controlled Unit User Manual PDF

High-Performance

Pan-Tilt Unit

User Manual

MODEL: PTU-5

VERSION: 3.01

REVISION DATE: February 23, 2018

PTU-5 User Manual

DOCUMENT CONTROL

COPYRIGHT NOTICE

PTU-5 Users Manual, version 3.00 (11/2017) 2018 by FLIR Systems, Inc., 6769 Hollister Avenue, Goleta, CA 93117, (805)964-9797, FAX: (805)690- 5933 www.FLIR.com/MCS

All rights reserved. Protected under numerous U.S. patents, including 5463432 and 5802412 with other patents pending. No part of this book may be reproduced, stored in a retrieval system, or transcribed in any form or by any means including but not limited to electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of FLIR Systems, Inc.

The information in this manual is subject to change without notice and, except for the warranty, does not represent a commitment on the part of FLIR Systems, Inc. FLIR Systems, Inc. cannot be held liable for any mistakes in this manual and reserves the right to make changes.

Date Author Rev. # Changes

03/2017 A. Hernandez 1.00 Initial production release

08/2017 A. Hernandez 2.00 Update wiring, add vent hole warnings

11/2017 A. Hernandez 3.00 Update wiring and miscellaneous updates

02/2018 A. Hernandez 3.01 Correct 26-pin numbering

Copyright 2018, FLIR Commercial Systems, Inc.

Table of Contents

1 - Introduction ................................................................................................................................. 1 1.1 - General PTU Features ........................................................................................................................ 1 1.2 - PTU-5 Features .................................................................................................................................. 2 1.3 - Applications ....................................................................................................................................... 2 1.4 - Whats Different About the PTU-5 .................................................................................................... 3 1.5 - About This Manual ............................................................................................................................ 3

1.5.1 - Formatting Conventions ........................................................................................................... 3 1.6 - Model Number .................................................................................................................................. 4 1.7 - PTU Package Contents ...................................................................................................................... 4 1.8 - Related Documentation .................................................................................................................... 5 1.9 - Additional Resources ......................................................................................................................... 5 1.10 - Technical Support ............................................................................................................................ 5

2 - Safety ........................................................................................................................................... 7 2.1 - Overview ........................................................................................................................................... 7 2.2 - Safety Warnings and Cautions ........................................................................................................... 7

3 - Quick Start ................................................................................................................................... 9 3.1 - System Overview ............................................................................................................................... 9 3.2 - Installation Components ................................................................................................................. 10 3.3 - Basic Setup ...................................................................................................................................... 10 3.4 - Ethernet Connection ....................................................................................................................... 11 3.5 - Serial Connection ............................................................................................................................ 13

4 - Installation & Setup .....................................................................................................................15 4.1 - Mounting the Unit ........................................................................................................................... 15 4.2 - Wiring and Connectors .................................................................................................................... 16

4.2.1 - Mechanical Overview ............................................................................................................. 16 4.2.2 - Wiring ..................................................................................................................................... 16

4.3 - Power Sources ................................................................................................................................. 17 4.4 - Shielding .......................................................................................................................................... 17 4.5 - Interface and Host Settings ............................................................................................................. 18

4.5.1 - Ethernet Connection .............................................................................................................. 18 4.5.2 - RS-485 Electrical Connection .................................................................................................. 18

4.6 - Initial Power-Up and Test ................................................................................................................ 19 4.6.1 - Web Interface ......................................................................................................................... 19 4.6.2 - Terminal Interface .................................................................................................................. 19

4.7 - Payload Mounting ........................................................................................................................... 20 4.7.1 - Side Bracket Attachment ........................................................................................................ 20 4.7.2 - Payload Attachment ............................................................................................................... 21

Copyright 2018, FLIR Commercial Systems, Inc. iii

PTU-5 User Manual

5 - Configuring & Programming ....................................................................................................... 25 5.1 - Range of Motion .............................................................................................................................. 25

5.1.1 - Default Limits ......................................................................................................................... 26 5.2 - Resolution and Step Modes ............................................................................................................ 26

5.2.1 - Resolution ............................................................................................................................... 27 5.3 - User-Programmable Settings .......................................................................................................... 27

5.3.1 - High-Speed Operation ............................................................................................................ 27 5.3.2 - Heavy-Payload Operation ....................................................................................................... 28 5.3.3 - Battery Powered Operation ................................................................................................... 29

F - Electrical Specifications ................................................................................................................. 1 6.1 - 26-Pin Base Connector ...................................................................................................................... 2 6.2 - 12-Pin Payload Connector ................................................................................................................. 3 6.3 - 26-Pin Breakout Cable ....................................................................................................................... 4 6.4 - PTU-5 Internal Wiring ........................................................................................................................ 5

G - Mechanical Drawings ................................................................................................................... 1

H - Networking .................................................................................................................................. 1 8.1 - Ethernet ............................................................................................................................................. 1 8.2 - Serial .................................................................................................................................................. 1

8.2.1 - Serial Networking Connections ................................................................................................ 2 8.2.2 - ASCII Command Syntax ............................................................................................................ 3 8.2.3 - Serial Command List ................................................................................................................. 4

I - Troubleshooting ............................................................................................................................ 1 9.1 - Mechanical ........................................................................................................................................ 1 9.2 - Power ................................................................................................................................................ 1 9.3 - Networking ........................................................................................................................................ 1 9.4 - Technical Support .............................................................................................................................. 2

J - Regulatory & Warranty Information .............................................................................................. 1 10.1 - Regulatory Information ................................................................................................................... 1 10.2 - About FLIR Systems, Inc. ................................................................................................................. 2 10.3 - Limited Warranty ............................................................................................................................ 3

Copyright 2018, FLIR Commercial Systems, Inc.iv

1 - Introduction

The PTU-5 provides the fastest, most accurate pan-tilt unit in its size class that allows you to mount and aim cameras, antennas, lasers, and other payloads. This User Manual contains setup, general configuration, wiring, and mechanical interface information that is intended for use by design engineers and integrators who are configuring, installing, and programming the PTU. Please see Related Documentation on page 5 for a list of other documents related to FLIR PTUs.

1.1 - General PTU Features The PTU-5 offers the following general features:

Extra small, rugged, portable MIL-spec design with low weight and high performance

Turn on and begin slewing to track moving targets in seconds (<5 seconds startup time)

Reduced calibration movement (PTU-5 does not need to home to 0,0).

Programmable ranges of motion

Output shaft encoders ensure reliability and accuracy

High holding torque with no droop on power off

MIL-STD shock and vibration tested

Flexible design supports a wide range of applications and sensors

Shared common firmware and command set with other FLIR PTUs

26-pin base connector for simplified wiring with direct connections to power and the host PC

Slip ring for continuous 360 pan operation with no external payload cables.

Serial communication capability via terminal or computer

Simple ASCII command mode

High-speed binary command interface

Constant-current motor drives for increased performance and control

Flexible connectivity options

Unregulated 12-30 VDC power input

Copyright 2018, FLIR Commercial Systems, Inc. 1

PTU-5 User Manual

1.2 - PTU-5 Features In addition to the general features listed above, the PTU-5 offers the following features:

Payload (top mount): 5lbs

Payload (side mount): 6lbs (two 3lb loads)

Dimensions: 6.2 x 4.9 x 6 (approximately 158mm x 125mm x 153mm)

Swept volume: 0.17 cubic feet, with no external motor cable

Weight: 4lbs (approximately 1.81kg)

Pan and Tilt Resolution: 0.005 in eighth-step mode

Accuracy/Repeatability: 0.1

Range of Motion: 360 continuous pan, +/-180 tilt (side mount only)

Axis Speeds: 120/second pan; 50/second tilt

Slip Ring Channels: 11 (including power, video, serial, and Ethernet)

Connectors: HD26 (base), M12 (payload; Phoenix Contact #1411979, mates to #1411987)

Voltage: 12-30VDC input, 24VDC internal, with built-in reverse polarity protection

Please refer to the PTU-5 Product Datasheet for complete specifications.

1.3 - Applications The PTU-5 is well suited for the following applications:

Mid- and short-range surveillance systems

Automated detection and tracking

Visible and thermal cameras

Industrial automation

Harbor and port security

Border security & law enforcement

Highway & transportation monitoring

Military special operations

Robotics & computer vision.

Copyright 2018, FLIR Commercial Systems, Inc.2

Chapter 1: Introduction

1.4 - Whats Different About the PTU-5 Users who are familiar with other FLIR pan tilts will notice the following differences in the PTU-5:

The PTU-5 uses different connectors than those used on other PTUs; however, these connectors also conform to established industry standards.

The PTU-5 uses a hybrid drive with both belts and gears.

Encoders included on the output axes allow the PTU-5 to reset to locations other than home.

The encoders correct for backlash and other nonlinearities for a more accurate output angle measurement.

The Web interface shows motion in both degrees and steps.

1.5 - About This Manual This section describes the formatting conventions and information contained in this manual.

1.5.1 - Formatting Conventions

This manual uses several formatting conventions to present information of special importance.

Lists of items, points to consider, or procedures that do not need to be performed in a specific order appear in bullet format:

Item 1

Item 2

Procedures that must be followed in a specific order appear in numbered steps:

1. Perform this step first.

2. Perform this step second.

Specific keyboard keys are depicted in square brackets and are capitalized, for example: [ESC]. If more than one key should be pressed simultaneously, the notation will appear as [KEY1]+[KEY 2], for example [ALT]+[F4].

Interface elements such as document titles, fields, windows, tabs, buttons, commands, options, and icons appear in bold text.

Menus and submenus have the notation Menu>Submenu. For example, Select File>Save means that you should first open the File menu, and then select the Save option.

Specific commands appear in standard Courier font. Sequences of commands appear in the order in which you should execute them and include horizontal or vertical spaces between commands.

Copyright 2018, FLIR Commercial Systems, Inc. 3

PTU-5 User Manual

This manual also contains important safety information and instructions in specially formatted callouts with accompanying graphic symbols:

1.6 - Model Number Each PTU unit includes a model number that is located on the base of the unit. This number lists the options present on that particular unit. The PTU-5 model number is 445-0005-01-00.

1.7 - PTU Package Contents Your PTU package includes the following items:

PTU-5 unit

AC/DC power supply with cord (PT-PS-30V-NA) - optional

Payload mounting brackets (top standard; side optional)

Mating connector for payload (Molex #1200655109) - optional

Breakout cable (308-0278-XX-00, where XX is the cable length in feet); available in various lengths - optional

USB to RS-485 adapter cable - optional

PTU-5 Series Quick Start Guide

WARNING: WARNINGS ALERT YOU TO THE POSSIBILITY OF PERSONAL INJURY IF THESE INSTRUCTIONS ARE NOT FOLLOWED.

CAUTION: CAUTIONS ALERT YOU TO THE POSSIBILITY OF EQUIPMENT OR PROPERTY DAMAGE IF THESE INSTRUCTIONS ARE NOT FOLLOWED.

Note: Notes provide helpful information.

Copyright 2018, FLIR Commercial Systems, Inc.4

Chapter 1: Introduction

1.8 - Related Documentation The following additional documentation is available for your PTU:

PTU Product Datasheet:product specifications for your specific PTU model

Pan-Tilt E Series Command Reference Manual: command instructions

1.9 - Additional Resources FLIR Systems, Inc. also maintains a technical support Web site with additional resources for customers in the Support section at www.FLIR.com/MCS. Resources include electronic copies of user manuals, firmware downloads, 3D CAD models, technical notes, and other information.

1.10 - Technical Support FLIR Systems, Inc. provides a range of technical support options:

Email: MCS-Support@flir.com

Web: www.FLIR.com/MCS

Phone: (888)747-3547

The preferred method of contacting Technical Support is via email, which helps ensure proper dispatching and tracking to address your questions promptly.

When contacting Technical Support, please provide the following information:

PTU model and configuration

Payload (Please include photos, if possible.)

Parameter settings

Description of issue/symptoms

Copyright 2018, FLIR Commercial Systems, Inc. 5

PTU-5 User Manual

This page intentionally left blank.

Copyright 2018, FLIR Commercial Systems, Inc.6

2 - Safety

2.1 - Overview This chapter contains important safety instructions. You must read, understand, and comply with all of these safety instructions in order to protect both persons and property. The benefits of a safe installation include increased usability, reliability, and reduced damage to the PTU, payload, and/or other property.

2.2 - Safety Warnings and Cautions PTU installation and setup should be only be performed by qualified personnel.

The installation must comply with all applicable codes (such as building codes, marine safety codes, etc.).

The installation must be free of obstructions throughout the entire potential range of pan-tilt motion, which may extend beyond user-specified limits when the PRU is resetting. When planning the installation, make sure to take the payload into account to ensure that the PTU and payload remain unobstructed at all times.

All mounting methods and materials must be capable of supporting at least four times the combined weight of the PTU, mounted payloads, and cabling.

Corrosion-resistant hardware (such as stainless steel screws) must be used for all outdoor installations.

Do not install the PTU in any location that exceeds the PTUs environmental specifications.

Always incorporate a readily accessible power disconnect into the installation wiring. (See Basic Setup on page 10 and Wiring and Connectors on page 16.)

Removing power by disconnecting the power cable or cable harness is not recommended and can result in damage to the system.

All service procedures must be performed by qualified service personnel in accordance with all applicable instructions.

If the PTU is damaged, immediately remove power and contact FLIR Systems, Inc.

Only use replacement parts recommended by FLIR Systems, Inc.

Use caution when lifting the PTU and/or payload.

Copyright 2018, FLIR Commercial Systems, Inc. 7

PTU-5 User Manual

Keep all persons and objects well away from the PTU panning and tilting radius with payload installed.

Do not touch or otherwise handle the PTU while in motion or if there is a possibility of motion. Always remove power before servicing the PTU and/or payload.

Copyright 2018, FLIR Commercial Systems, Inc.8

3 - Quick Start

The PTU provides direct Ethernet and serial control for all motions. You may also use a joystick or proprietary controller.

This chapter helps you power up your PTU and test direct communications from a host computer.

3.1 - System Overview The PTU includes an integrated controller that can be accessed using a Web/Ethernet interface. The controller will also accept control commands from any host computer over a serial (RS-485) connection. The basic connections are:

DC power

Pan-tilt control via either Ethernet or RS485 serial connection

The PTU also allows payload pass-through wiring that internally routes payload signals (payload power, video, etc.) from a single stationary connector in the PTU base to a single payload connector that moves with your payload.

Figure 3-1: Pan-Tilt System Overview

You may control the PTU from any host computer using either the built-in Web interface or the ASCII protocol described in the included Pan-Tilt E Series Command Reference Manual. The PTU also supports a binary protocol via a C Software Development Kit (PTU-SDK) for high speed, hard real-time controls such as tracking. Drivers are also available using third-party software packages such as LabVIEW and digital video control systems.

Basic PTU Connections - Ethernet 4C - RS-485 Serial (w/USB adapter)

Host

PTU

Copyright 2018, FLIR Commercial Systems, Inc. 9

PTU-5 User Manual

3.2 - Installation Components A complete PTU-5 system configuration requires the following components:

PTU-5 (not shown)

AC/DC power supply (PT-PS-INT-30V) Optional (1)

Breakout cable (308-0278-XX-00) Optional (2)

USB to RS-485 converter (PTU-CONV- USB-RS485) Optional (3)

Side payload mounting brackets (261- 2664-00) Optional (4)

PTU-5 Users Manual (this document; available for download)

Pan-Tilt E Series Command Reference Manual (available for download)

3.3 - Basic Setup To perform a basic PTU setup and installation:

1. Mount the PTU securely to a lab bench, tripod, or other stable platform. Verify that there is enough clearance around the unit. See Mounting the Unit on page 15 for detailed mounting instructions.

2. Attach either the optional breakout cable or customer- supplied cable to the 26-pin connector at the base of the PTU by inserting the cable into the connector and then tightening the mounting screws (one each on the left and right sides of the connector).

CAUTION: DISCONNECTING THE CABLE WHILE THE PTU IS POWERED ON CAN DAMAGE THE UNIT. ALWAYS POWER DOWN THE PTU BEFORE DISCONNECTING THE CABLE.

CAUTION: THE HOLE ON THE SIDE OF THE PTU COVER IS NOT A RESET BUTTON. DO NOT INSERT ANY OBJECT INTO THIS HOLE AS IT MAY PIERCE THE WATERTIGHT MEMBRANE AND EXPOSE THE PTU TO MOISTURE DAMAGE.

1

2

3

4

Copyright 2018, FLIR Commercial Systems, Inc.10

Chapter 3: Quick Start

3. Connect the AC plug on the power supply into a power strip with a switch, and then connect the DC connector to either the breakout cable or customer-supplied cable.

4. Establish Ethernet or serial wiring to the PTU as appropriate for your needs.

- Please see Ethernet Connection on page 11 for Ethernet/Web instructions.

- Please see Serial Connection on page 13 for serial/ASCII instructions.

5. Power on and test the PTU.

6. Attach a payload to the top or side brackets.

3.4 - Ethernet Connection The PTU contains a Web-based interface that allows you to test and program various functions. This interface is accessible via the Ethernet connection on the breakout cable.

To connect, power on, and test the PTU using the Ethernet connection and Web interface:

1. Connect one end of an RJ-45 Ethernet cable to the PTU, and then connect the other end of the cable to the host computer, either directly or through a router/hub.

2. Connect a power source to the PTU, making sure to incorporate a readily accessible power disconnect (such as a power strip) to allow safe power removal from the system.

3. Ensure that the PTU is clear to move in both axes (pan and tilt) without hitting any obstructions before applying power.

4. Power on the PTU. When the PTU-5 is powered up, it goes through a short reset in both axes. The amount of motion on reset will vary at different areas of the axis, but generally it will move no more than 12 degrees in either direction.

CAUTION: THE PTU-5 DOES NOT SUPPORT SIMULTANEOUS MOUNTING OF PAYLOADS ON BOTH THE TOP AND SIDE BRACKETS.

Note: You may use simultaneous Ethernet and serial connections.

CAUTION: REMOVING POWER BY PULLING THE PLUG CAN DAMAGE THE PTU.

WARNING: HITTING AN OBSTACLE WHILE THE PTU IS IN MOTION COULD CAUSE A MOUNTING OR OTHER STRUCTURAL FAILURE THAT COULD RESULT IN INJURY OR DEATH.

Copyright 2018, FLIR Commercial Systems, Inc. 11

PTU-5 User Manual

5. Launch a Web browser. The PTU supports modern versions of the Microsoft Internet Explorer, Mozilla Firefox, and Google Chrome browsers with JavaScript enabled.

6. Download the PTU Finder utility from FLIR. A list of the individual PTUs currently connected to the network and their corresponding IP addresses will appear in the application window.

7. In your browser, navigate to the appropriate IP address (such as http:/ /192.168.1.101). A web page appears when you are connected to the selected PTU. The PTU Web interface allows you to configure the network interface, configure various parameters, and control the PTU.

8. Navigate to the PTU Control page.

9. Click the arrows to pan and tilt the PTU and verify that it is working properly. You can use the Units radio buttons to specify the units to use (either Degrees or Steps).

Please refer to the Pan-Tilt E Series Command Reference Manual for instructions on using the Web interface.

Note: If you have simultaneous Ethernet and serial connections to a PTU, you may enter NI in the terminal to retrieve the IP address of the PTU.

Copyright 2018, FLIR Commercial Systems, Inc.12

Chapter 3: Quick Start

3.5 - Serial Connection

To connect, power on, and test the PTU using the serial interface:

1. Connect the PTU as follows:

- Attach the DB25 to DB9 converter on one side of the RS-232 to RS-485 converter.

- Attach one end of the four-pin RJ-11 phone cable to the other side of the RS-232 to RS-485 adapter.

- Set the switches on the RS-232 to RS-485 con- verter to T RxON and DCE.

- Attach the four-pin RJ-11 female-to-female adapter to the other end of the phone cable. This is important because the adapter rearranges the pins; the PTU will not function if the adapter is not attached correctly.

- Connect the RS485 connector from the breakout cable into the adapter.

- Provide power to the converter through the included power supply.

- Alternatively, you can connect the USB to RS-485 cable (PTU-CONV-USB-RS485) to a USB port on the host PC and the RJ-11 connector on the breakout cable.

2. Open a terminal program such as HyperTerminal or TeraTerm.\

3. Create a new connection with the following communications parameters:

- 9600 baud

- 8 data bits

- 1 stop bit

- no parity

- no handshaking

Note: You may use simultaneous Ethernet and serial connections.

Note: HyperTerminal is available with Microsoft Windows XP and previous versions. You may download TeraTerm from http://ttssh2.sourceforge.jp/.

RS-232 to RS-485 adapter

DB9 to DB25 adapter

F-F adapter

RS-232

Phone cord

Copyright 2018, FLIR Commercial Systems, Inc. 13

PTU-5 User Manual

4. Provide DC power to the PTU. The factory cable (part number 308-0278-XX-00) allows easy plug-in power from the factory AC/DC power supply model PT-PS-INT-30V. Alternatively, you may provide your own DC power source if appropriate.

5. Power on the PTU by turning on the switch on the power strip. If power is working, the unit will begin a self- calibration and text will appear on your terminal identifying the units configuration.

6. Test pan-tilt operation by typing commands into your terminal program. The following command sequence will familiarize you with basic PTU-D48E operation:

pp2500 tp-900 PS1900 pp0

This sequence:

- sets the pan axis to position 2500

- sets the tilt axis to position -900

- sets the pan speed to 1900 positions per second, and

- sets the pan position back home.

7. Power down the PTU by turning off the switch on the power strip.

8. Mount and wire your payload (e.g. camera) on the PTU, as described in Installation & Setup on page 15.

Please see ASCII Command Syntax on page C-3 for an overview of the ASCII command syntax and a list of commonly used commands. The Pan-Tilt E Series Command Reference Manual contains complete command interface instructions.

CAUTION: USE AN APPROPRIATELY RATED POWER STRIP WITH SURGE PROTECTION TO ALLOW SAFE POWER REMOVAL WHEN YOU ARE READY TO POWER DOWN.

Copyright 2018, FLIR Commercial Systems, Inc.14

4 - Installation & Setup

This section describes proper mechanical and electrical PTU-5 installation.

4.1 - Mounting the Unit The basic mounting pattern uses four #1/4-20 screws in a 1.18 (30mm) by 2.28 (58mm) rectangular pattern. All four mounting screws must be used, and mount must be strong enough to support the combined load of the PTU, payload, and additional forces exerted on the system (such as wind, G forces, etc.). A good rule of thumb is that the mount must be capable of supporting at least four times the combined weight of the PTU and payload. For example, a mount for a PTU-5 must be able to support at least 48lbs.

Figure 4-1: Hole Mounting Patterns

WARNING: FAILURE TO USE ALL FOUR MOUNTING SCREWS AND/OR TO SECURE THE PTU AND ITS PAYLOAD TO A SUFFICIENTLY STRONG MOUNTING CAN CAUSE THE INSTALLATION TO FAIL. THIS CAN RESULT IN PERSONAL INJURY OR DEATH, AND/OR DAMAGE TO THE PTU AND/OR PAYLOAD.

1.18 30.0

2.28 58.0

4X 1/4 - 20 TAPPED HOLE

Copyright 2018, FLIR Commercial Systems, Inc. 15

PTU-5 User Manual

4.2 - Wiring and Connectors The PTU-5 has both a base connector and a payload connector for customer attachment. Please refer to Electrical Specifications on page A-1 for detailed pin-out and connector requirements.

4.2.1 - Mechanical Overview

The PTU-5 contains two receptacles.

Base Receptacle: The base of the PTU-5 houses the 26-pin base connector.

Payload Receptacle: The payload connector is a 12-pin circular M12 receptacle.

Basic control requires connecting a DC power source and a host PC to the PTU. The supplied breakout cable and power supply allow you to have your PTU plugged in and running within minutes. Electrical Specifications on page A-1 contains specific pin outs and wiring diagrams for the available PTU wiring configurations; if needed, you may use this information to make custom cables to suit your specific installation requirements. Please refer to Quick Start on page 9 for basic connection and power-on instructions.

The PTU-5 also provides payload pass-through signals that connect between pins in the base receptacle to corresponding pins in the payload receptacle. Additional pins in the base receptacle provide other controls to the PTU controller board, including both RS485 and Ethernet controls.

4.2.2 - Wiring

The PTU is offered with one wiring configuration that includes the following connections:

1 power circuit (4C)

Chassis ground (2C)

1 Ethernet connection (4C; to PTU internal electronics only)

1 RS485 connection (4C)

11 general I/O lines (11C)

The PTU-5 requires a minimum of ten connections at the base for power, RS-485 communications, and shielding.

Note: The PTU-5 is IP67 rated with no payload cable attached. If you need a payload cable, then that cable should be designed so as to maintain the IP67 rating. FLIR recommends using the Molex #1200655109 cable.

CAUTION: ALWAYS FOLLOW ALL APPLICABLE SPECIFICATIONS (INCLUDING BUT NOT LIMITED TO MAXIMUM VOLTAGE AND CURRENT) WHEN ATTACHING PAYLOAD SIGNALS TO THE SYSTEM.

Copyright 2018, FLIR Commercial Systems, Inc.16

Chapter 4: Installation & Setup

4.3 - Power Sources The PTU requires an unregulated 12-30VDC power source capable of 17 continuous peak watts. Since the PTU has a DC to DC converter, you may not see reduced performance if you use a lower-voltage power supply.

4.4 - Shielding Shielding protects the PTU from external Electromagnetic Interference (EMI) and prevents radiation emission from internal and external cabling. Proper shielding must be used to meet the regulatory requirements described in Regulatory & Warranty Information on page E-1. All PTU wiring configurations provide a shield pin at both the base and the payload, as described in Electrical Specifications on page A-1. This shield is also attached to the PTU housing. The shield pin is not connected to ground internally. The shield potential will vary from ground and must not be confused with a ground pin.

Ideally, either the PTU chassis or the shield pin at the base connector should be routed to a long grounding rod that is embedded in the ground. If needed, it is also acceptable to route the shield pin to the power ground through a surge protection device.

CAUTION: THE PTU CONTAINS REVERSE POLARITY, OVER-VOLTAGE AND OVERCURRENT PROTECTION; HOWEVER, SUSTAINED OVERLOAD CAN DAMAGE THE UNIT.

CAUTION: THE PTU WILL NOT BE PROPERLY SHIELDED UNTIL THE SHIELD PIN IS PROPERLY CONNECTED.

Copyright 2018, FLIR Commercial Systems, Inc. 17

PTU-5 User Manual

4.5 - Interface and Host Settings The PTU-5 includes both an Ethernet connection and RS-485 communications. You may connect to your PTU using either or both of these methods; the Web interface is only available when using an Ethernet connection, and the terminal interface is only available when using a serial connection.

4.5.1 - Ethernet Connection

The PTU Ethernet connection uses a standard Cat-5 (RJ-45) network cable.

You may connect the PTU directly to a host computer or indirectly through a router, hub, etc.

The PTU will either accept IP addresses from a DHCP server or select its own IP address if connected directly to the host computer.

If needed, you may use a coupling to extend the Ethernet connection on the breakout cable.

Connect, power on, and test the PTU using the Ethernet connection and Web interface as described in Ethernet Connection on page 11.

4.5.2 - RS-485 Electrical Connection

The PTU RS-485 communications use the following connections:

Duplex: full

Connections: Tx+, Tx-, Rx+, and Rx-

Voltage: RS-422 or RS-485 levels

Serial communication between the PTU and your host computer should be set as follows:

Baud rate: 9600. You may adjust the baud rate using software commands. Please refer to the Pan- Tilt E Series Command Reference Manual for instructions.

Start bit: 1

Data bits: 8

Stop bit: 1

Handshaking: off

XON/XOFF: not used

Note: The Ethernet and serial interfaces may be connected simultaneously; however, you should only use one interface at a time for command and control of the PTU.

Copyright 2018, FLIR Commercial Systems, Inc.18

Chapter 4: Installation & Setup

4.6 - Initial Power-Up and Test This section describes how to power up and test your PTU using either the Web or serial interface. Test and verify all cable connections and connector wiring before power-up.

4.6.1 - Web Interface

To test the PTU using the Web interface, follow the procedure in Ethernet Connection on page 11 to connect the PTU, power on the unit, and access the Web interface.

The Web interface has a number of pages, including:

PTU Config: Allows you to configure speed, acceleration, and power options.

Network: Allows you to configure the PTUs IP and MAC addresses.

PTU Control: Allows you to control the PTU. Use this page to test PTU motion and exercise the unit.

Please see the Pan-Tilt E Series Command Reference Manual for more information about the Web interface.

4.6.2 - Terminal Interface

To test the PTU using the serial interface:

1. Configure the RS-485 port on the host computer as described in Serial Connection on page 13.

2. Power up the PTU. A boot message will appear on your terminal screen and the unit will begin a reset cycle. An asterisk (*) appears on your screen when the reset cycle is finished. If the PTU did not reset properly, please refer to the troubleshooting instructions below.

3. Please see Serial Command List on page C-4 for a list of basic commands, and the Pan-Tilt E Series Command Reference Manual for a complete list of commands and associated parameters and other usage instructions.

Note: Complete the initial installation and testing, then exercise the PTU and familiarize yourself with its operations and commands before mounting your payload (such as a camera).

Copyright 2018, FLIR Commercial Systems, Inc. 19

PTU-5 User Manual

4.7 - Payload Mounting The PTU payload bracket system can be configured in a number of ways to support a variety of payloads including cameras, lasers, antennas, and other equipment. Figure 3 shows all bracket configurations available for the PTU-5.

The following guidelines apply to all payload mounts:

The maximum payload mounting screw diameter is 1/4 when using the center hole on each bracket (slots accommodate smaller screws). Also, payload mounting screws must not extend more than 1/8 below the top mounting bracket, to avoid gouging the PTU housing.

Always use washers, lock washers, etc. as appropriate.

If the PTU is being mounted in an outdoor location, use corrosion-resistant hardware (such as stainless steel).

Apply thread locking compound to all screws, such as Loctite 242, which is suitable for applications that are field serviceable since it is easily removable with common hand tools and works with both stainless and plated metals. Consider other compounds for high-shock/vibration applications where field service is not a concern.

The PTU-5 allows the following bracket mounting options:

Figure 4-2: Bracketing Options

4.7.1 - Side Bracket Attachment

To attach side mounting brackets:

1. Verify that the PTU has been powered on and allowed to reset, which places the mounting hub in its home position.

2. Power off the PTU.

WARNING: FAILURE TO FOLLOW ALL PAYLOAD MOUNTING INSTRUCTIONS COULD RESULT IN A STRUCTURAL FAILURE THAT MAY RESULT IN DEATH, PERSONAL INJURY, AND/OR DAMAGE TO THE UNIT.

Copyright 2018, FLIR Commercial Systems, Inc.20

Chapter 4: Installation & Setup

3. Remove the top mounting bracket by removing the two screws and one clamp at either side of the bracket.

4. Orient the side bracket so the horizontal mounting arm is on the bottom.

5. Attach the bracket using one clamp secured with two screws torqued to 32 inch-pounds. The thread holes in the hub come with thread locking compound applied to them. Reapply thread lock to the hub whenever you remove the bracket using a compound such as Loctite 242.

6. Reset the PTU and ensure that the bracket moves properly throughout the entire range of motion.

4.7.2 - Payload Attachment

The following guidelines apply to all payload attachments:

Mount all payloads as close to the PTU as possible. This minimizes the distance between the payload Center of Gravity (CG) and the center of rotation of the axes, which reduces stress on the PTU and mounting. It also improves performance by reducing the amount of torque required to move the payload.

Verify that the payload will clear the PTU housing and all surrounding objects throughout the entire range of motion.

Your PTU is rated for the loads specified in PTU-5 Features on page 2; however, load distribution affects the actual weight that the PTU can safely move. The amount of torque needed to move a payload depends on a number of factors such as (but not limited to) payload weight, distance from the payload CG to the center of rotation, acceleration and speed settings, power levels, and environmental factors.

Note: If you ordered your PTU with a top bracket, the unit will arrive with the bracket already attached.

Note: Default tilt axis limits are set to +30/-90. If you will be using the PTU with side brackets only, then you may specify tilt axis limits up to +/- 90 using the TNU and TXU ASCII commands, as described in the Pan-Tilt E Series Command Reference Manual.

CAUTION: THE HOLE ON THE SIDE OF THE PTU COVER IS NOT A RESET BUTTON. DO NOT INSERT ANY OBJECT INTO THIS HOLE AS IT MAY PIERCE THE WATERTIGHT MEMBRANE AND EXPOSE THE PTU TO MOISTURE DAMAGE.

Side-mounted payload CG is closer to the tilt axis center of rotation and requires less torque.

Top-mounted payload CG is above the tilt axis center of rotation and requires more torque.

Copyright 2018, FLIR Commercial Systems, Inc. 21

PTU-5 User Manual

The PTU allows full control over acceleration, speed, and power levels. Mount your payload and configure these parameters appropriately to ensure reliable operation.

If your installation is not usable across the full range of motion, use the TXU, TNU, PXU, and/or PNU commands to set software motion limits. When resetting a PTU-5 that is positioned near those limits, the PTU may briefly move outside those limits.

To attach and test your payload:

1. Mount your payload. Side mounting is preferable for heavy loads because this keeps the payload CG closer to the tilt axis, thereby minimizing torque requirements.

2. Verify that the payload is securely attached to the payload bracket.

3. Move the PTU tilt axis through its entire range to test its ability to carry the load.

- If you are using the Web interface, open the PTU Control page and click the arrows to move the PTU through its full range of tilt motion, as described in the Pan-Tilt E Series Command Reference Manual. If needed, click Halt to stop the PTU immediately.

- If you are using the terminal interface, enter TN TX to query the tilt minimum and maximum limits, then enter TP A TP to cycle the PTU through its entire tilt range (where is the number returned by the TN query and is the number returned by the TX query). If needed, enter H to stop the PTU immediately.

If the load is too heavy or moving too quickly, the PTU will lose synchronization, which will be audible as a grinding sound from the PTU motors. Stop the test immediately if this occurs, and refer to Heavy-Payload Operation on page 28 and Battery Powered Operation on page 29. This does not damage the PTU but does indicate that the payload is not mounted and/or the PTU is not configured correctly to move the payload.

CAUTION: THE CG OF TOP-MOUNTED PAYLOADS IS FURTHER FROM THE TILT AXIS AND MAY REQUIRE MORE TORQUE THAN A SIMILAR SIDE-MOUNTED PAYLOAD.

WARNING: STOP THE PTU IMMEDIATELY BY EITHER CLICKING HALT (WEB INTERFACE) OR ISSUING AN H COMMAND (SERIAL INTERFACE) IF THE PAYLOAD IS ABOUT TO COLLIDE WITH THE PTU-5 AND/OR ANOTHER OBSTACLE. A COLLISION COULD CAUSE A STRUCTURAL FAILURE THAT MAY RESULT IN INJURY OR DEATH.

Note: Please refer to Heavy-Payload Operation on page 28 for more information on configuring the PTU for heavier payloads.

CAUTION: DO NOT PROCEED BEYOND THIS STEP UNLESS AND UNTIL THE PTU PASSES THE TILT AXIS MOTION TEST.

Copyright 2018, FLIR Commercial Systems, Inc.22

Chapter 4: Installation & Setup

4. Move the PTU pan axis through its entire range to test its ability to carry the load.

- If you are using the Web interface, open the PTU Control page and click the arrows to move the PTU through its full range of pan motion, as described in the Pan-Tilt E Series Command Refer- ence Manual. If needed, click Halt to stop the PTU immediately.

- If you are using the terminal interface, enter PN PP to query the pan minimum and maximum limits, then enter PN A PP to cycle the PTU through its entire tilt range (where is the number returned by the PN query and is the number returned by the PX query). If needed, enter H to stop the PTU immediately.

If the load is too heavy or moving too quickly, the PTU will lose synchronization, which will be audible as a grinding sound from the PTU motors. Stop the test immediately if this occurs, and refer to Heavy-Payload Operation on page 28 and Battery Powered Operation on page 29..

5. If the PTU passes the above pan and tilt axis load handling tests, you are ready to begin controlling your payload using the commands described in the Pan-Tilt E Series Command Reference Manual.

WARNING: STOP THE PTU IMMEDIATELY BY EITHER CLICKING HALT (WEB INTERFACE) OR ISSUING AN H COMMAND (SERIAL INTERFACE) IF THE PAYLOAD IS ABOUT TO COLLIDE WITH THE PTU AND/OR ANOTHER OBSTACLE. A COLLISION COULD CAUSE A STRUCTURAL FAILURE THAT MAY RESULT IN INJURY OR DEATH.

Copyright 2018, FLIR Commercial Systems, Inc. 23

PTU-5 User Manual

This page intentionally left blank.

Copyright 2018, FLIR Commercial Systems, Inc.24

5 - Configuring & Programming

This chapter describes how to configure and program your PTU.

Follow the appropriate instructions to connect the PTU-5 to the host computer, power it on, and access it via:

Web: Ethernet Connection on page 11.

Serial: Serial Connection on page 13.

5.1 - Range of Motion The PTU-5 range of motion can be limited in the following ways:

Factory: Factory limits are smaller than hard limits to prevent physical damage to the PTU and/or payload.

User: User limits are programmable limits that are smaller than hard limits and can be as large as factory limits.

The PTU-5 uses high-precision mechanical stops on the tilt axis. Resetting the PTU-5 may temporarily move the PTU beyond its software-configured range of motion in the tilt and/or pan axis.

Note: You may also have a simultaneous Ethernet connection to the Web interface, as described in Ethernet Connection on page 11.

Copyright 2018, FLIR Commercial Systems, Inc. 25

PTU-5 User Manual

5.1.1 - Default Limits

In Figure 5-1:

The positive pan axis direction is clockwise when looking down at the top of the PTU.

The positive tilt axis direction is clockwise when looking sideways at the PTU with the motors and connectors facing to the right.

Figure 5-1: Pan-Tilt Default Factory Limits (PTU-D100 shown with identical limits to the PTU-5)

5.2 - Resolution and Step Modes The PTU uses stepper motors that drive the unit through a gear reduction system. The internal controller allows stepper motor control in manual (, , and 1/8) or automatic step modes. The following table lists the pan and tilt axis resolution in degrees.

Note: The default pan axis user limits are +/- 168. The default tilt axis limits are +30 and -90. You can only use the full +/-90 tilt axis with side brackets because the top bracket will impinge on the PTU body.

Note: Larger step modes increase torque and maximum speed vs. smaller step modes. The PTU includes an automatic stepping mode (auto-step) that optimizes this trade-off for many applications. You may command the PTU in 1/8 steps when in automatic stepping mode.

Copyright 2018, FLIR Commercial Systems, Inc.26

Chapter 5: Configuring & Programming

5.2.1 - Resolution

This table displays the PTU-5 pan and tilt resolutions.

5.3 - User-Programmable Settings The PTU has a number of user-programmable parameters that can significantly affect performance for a given payload and application. These parameters should be set to values that are appropriate for your payload and application needs. This section provides an overview of how to optimize your PTU for high- power and/or high-speed operation. Please refer to the Pan-Tilt E Series Command Reference Manual for complete instructions.

5.3.1 - High-Speed Operation

The following factors should be considered when planning high speed operation:

Load weight, weight distribution, and dynamics.

- Move the payload as close to the axis centers of rotation as possible. Doing this will reduce the torque required to move the payload and allow a higher top speed.

- Balancing the load, such as by using a counterweight or splitting the payload into two pieces can also help significantly.

Desired upper speed limit.

Rate of acceleration.

The base (start-up) speed.

Power supply voltage. Higher voltages within the permissible range significantly improve axis speed and acceleration performance.

In-motion power modes. If the duty cycle is less than 20%, you may use high move power to increase the top speed.

STEP STEP 1/8 STEP

PAN AXIS 0.02 0.01 0.005

TILT AXIS 0.02 0.01 0.005

CAUTION: USE HIGH-SPEED AND/OR HIGH-POWER SETTINGS WITH CARE, PARTICULARLY WHEN MOUNTING A HEAVY AND/OR BULKY PAYLOAD.

WARNING: FAILURE TO ADEQUATELY SECURE THE PTU TO A MOUNTING THAT CAN WITHSTAND THE FORCES APPLIED BY BOTH HIGH-SPEED, HIGH-POWER MOVEMENT AND ENVIRONMENTAL FASCTORS SUCH AS VEHICLE MOVEMENT OR WIND CAN CAUSE A STRUCTURAL FAILURE RESULTING IN INJURY OR DEATH.

Copyright 2018, FLIR Commercial Systems, Inc. 27

PTU-5 User Manual

Multi-axis dynamics. Simultaneously moving the tilt and pan axes affects the forces exerted on the PTU.

Always begin high-speed tests on each axis in isolation. Only perform simultaneous pan-tilt movements once each individual axis is optimized.

The base speed is the PTU minimum speed. In practice, the unit will instantly accelerate to this speed. Setting a base speed can help speed up movement by eliminating a segment of acceleration time.

Aggressive acceleration settings with heavy payloads can cause increased wear on the PTU.

An example configuration string for high speed operations is:

PA9000 PU6000 TA9000 TU6000 DS

5.3.2 - Heavy-Payload Operation

If the PTU fails the initial load handling tests, you may be able to program it for higher-power operations. The speed and acceleration of a mechanical system depend on the inertial properties of the payload. The ability of the PTU to successfully move the payload without losing synchronization depends upon the inertial payload factors and their relationship to power supply voltage, unit speed, acceleration, position, motor torque, etc.

To increase payload capacity:

Configure the PTU for increased motor current and torque. If your move duty cycle is less than 20%, you can set the Move Power to High (Web) or use the following serial commands: PMH TMH PHR THR.

You may also:

Move the payload CG closer to the PTU tilt axis. See Payload Attachment on page 21.

Determine if the payload can be modified to lighten it.

Set the base speed to 0.

If the PTU is having trouble resetting the tilt axis, try using user limits to reduce the tilt-axis range of motion.

Reduce speed and/or acceleration.

Please refer to the Pan-Tilt E Series Command Reference Manual for more information.

Copyright 2018, FLIR Commercial Systems, Inc.28

Chapter 5: Configuring & Programming

5.3.3 - Battery Powered Operation

The PTU can be battery powered. Battery-powered applications must conserve as much power as possible. The PTU includes commands that control pan-tilt motor power consumption both while moving and when stopped. For example, you can use the PHO and THO commands to set holding power to off. Please refer to the Pan-Tilt E Series Command Reference Manual for more information.

CAUTION: ALWAYS USE A FUSE WHEN CONNECTING THE PTU TO A BATTERY.

Copyright 2018, FLIR Commercial Systems, Inc. 29

PTU-5 User Manual

This page intentionally left blank.

Copyright 2018, FLIR Commercial Systems, Inc.30

A - Electrical Specifications

This Appendix describes the PTU-5 wiring. Please refer to Mechanical Overview on page 16 for a mechanical overview.

In general:

TX lines carry data from the PTU-5.

RX lines carry data to the PTU-5.

CAUTION: DO NOT EXCEED MAXIMUM RATED PASS-THROUGH AMPERAGES. FUSE PAYLOADS AT RATED TRIP VALUES. THE PTU-D300E WARRANTY DOES NOT COVER DAMAGE CAUSED BY OVERCURRENT SITUATIONS.

CAUTION: ALWAYS TERMINATE THE SHIELD LINE TO AN APPROPRIATE SYSTEM SHIELD OR GROUND CONNECTION.

Copyright 2018, FLIR Commercial Systems, Inc. A-1

PTU-5 User Manual

A.1 - 26-Pin Base Connector This table displays the PTU-5 D-Sub HD26-pin connector pin assignments.

PIN ASSIGNMENT 1 PTU POWER SUPPLY 2 PTU POWER SUPPLY RETURN 3 PTU_PHY_RXP 4 PTU_RS485_TX- 5 PTU_RS485_GROUND 6 PAYLOAD SIGNAL 6 7 PAYLOAD SIGNAL 9 8 PAYLOAD SIGNAL 2 9 CHASSIS GROUND

10 PTU POWER SUPPLY 11 PTU_PHY_TXP 12 PTU_PHY_RXN 13 PTU_RS485_RX+ 14 PAYLOAD SIGNAL 7 15 PAYLOAD SIGNAL 10 16 PAYLOAD SIGNAL 3 17 PAYLOAD SIGNAL 4 18 CHASSIS GROUND 19 PTU POWER SUPPLY RETURN 20 PTU_PHY_TXN 21 PTU_RS485_TX+ 22 PTU_RS485_RX- 23 PAYLOAD SIGNAL 11 24 PAYLOAD SIGNAL 5 25 PAYLOAD SIGNAL 8 26 PAYLOAD SIGNAL 1

86 74 52 31

17 181615 1411 12

25 262421 2220

10

19 23

9

15

Copyright 2018, FLIR Commercial Systems, Inc.A-2

Appendix A: Electrical Specifications

A.2 - 12-Pin Payload Connector This table displays the PTU-5 M12 12-pin payload connector pin assignments.

PIN ASSIGNMENT 1 PAYLOAD SIGNAL 3 2 PAYLOAD SIGNAL 6 3 PAYLOAD SIGNAL 7 4 PAYLOAD SIGNAL 11 5 PAYLOAD SIGNAL 10 6 PAYLOAD SIGNAL 9 7 PAYLOAD SIGNAL 4 8 PAYLOAD SIGNAL 1 9 PAYLOAD SIGNAL 2

10 PAYLOAD SIGNAL 5 11 NOT USED 12 PAYLOAD SIGNAL 8

9

8

7

6 5

4

3

2 10

1211

1

Copyright 2018, FLIR Commercial Systems, Inc. A-3

PTU-5 User Manual

A.3 - 26-Pin Breakout Cable This diagram displays the optional 26-pin breakout cable (308-0278-XX-00) wiring and connectors.

2

1 4

P

T U

-5 B

re a

k o

u t

C a

b le

N o

te :

S o

m e

o f

th e

s ig

n a

ls s

h o

w n

h e

re m

a y

n o

t b

e u

se d

in y

o u

r co

n fig

u ra

tio n

.

4 3

6 5

8 7

9

1 1

1 0

1 2

1 5

1 4

1 7

1 6

2 0

1 9

2 1

2 4

2 3

2 5

1 8

2 6

P o

w e

r co

n n

e ct

o r

(c e

n te

r h

o t)

P TU

S U

P P

L Y

(P IN

_1 =

W H

IT E

/R E

D ; P

IN _1

0 =

D A

R K

B LU

E )

P TU

S U

P P

L Y

R E

TU R

N (P

IN _1

9 =

K H

A K

I; P

IN _

2 =

P U

R P

LE )

1 8

P TU

_P H

Y _T

X P

(W H

IT E

/O R

A N

G E

)

P TU

_P H

Y _T

X N

(O R

A N

G E

)

P TU

_P H

Y _R

X P

(W H

IT E

/G R

E E

N )

P TU

_P H

Y _R

X N

(G R

E E

N )

P TU

_R S

4 85

_G N

D (B

L A

C K

)

P TU

_R S

4 85

_T X

+ (B

R O

W N

)

P TU

_R S

4 85

_T X-

(R E

D )

P TU

_R S

4 85

_R X

+ (W

H IT

E )

P TU

_R S

4 85

_R X-

(Y E

LL O

W )

1 9

8 7

6

54

3

1 0 1

2 1

1

2 2

1

1 3

2

1 3

P A

Y LO

A D

S IG

N A

L 5

(L IG

H T

B LU

E )

P A

Y LO

A D

S IG

N A

L 9

(G R

A Y

)

P A

Y LO

A D

S IG

N A

L 1

(Y E

LL O

W /G

R E

E N

)

C H

A S

S IS

G R

O U

N D

(N O

N E

)

P A

Y LO

A D

S IG

N A

L 3

(W H

IT E

/Y E

L LO

W )

P A

Y LO

A D

S IG

N A

L 4

(B LA

C K

/B LU

E )

P A

Y LO

A D

S IG

N A

L 7

(W H

IT E

/B LA

C K

)

P A

Y LO

A D

S IG

N A

L 6

(W H

IT E

/P U

R P

LE )

P A

Y LO

A D

S IG

N A

L 2

(B LA

C K

/R E

D )

P A

Y LO

A D

S IG

N A

L 10

( W

H IT

E /B

R O

W N

)

P A

Y LO

A D

S IG

N A

L 8

(W H

IT E

/G R

A Y

)

P A

Y LO

A D

S IG

N A

L 11

( W

H IT

E /B

LU E

)

D IN

M 1

2

E th

e rn

e t

co n

n e

ct o

r

R J1

1 6

P 4C

, ta

b u

p

Copyright 2018, FLIR Commercial Systems, Inc.A-4

Appendix A: Electrical Specifications

A.4 - PTU-5 Internal Wiring This diagram displays the internal PTU-5 wiring.

9

8 7

6 4

10

12 11

2

P T

U -5

In te

rn al

W ir

in g

N o

te :

S om

e of

t he

s ig

na ls

s ho

w n

he re

m ay

no

t be

u se

d in

y ou

r co

nf ig

ur at

io n.

4 3

6 5

8 7

9

11 10

12 15

14 16

20 19

21 24

23 25

18

P T

U S

U P

P L

Y (

P IN

_ 1

= W

H IT

E /R

E D

; P

IN _

1 0

= D

A R

K B

L U

E )

P T

U S

U P

P L

Y R

E T

U R

N (

P IN

_ 1

9 =

K H

A K

I; P

IN _

2 =

P U

R P

L E

)

P T

U _

P H

Y _

T X

P (

W H

IT E

/O R

A N

G E

)

P T

U _

P H

Y _

T X

N (

O R

A N

G E

)

P T

U _

P H

Y _

R X

P (

W H

IT E

/G R

E E

N )

P T

U _

P H

Y _

R X

N (

G R

E E

N )

P T

U _

R S

4 8

5 _

G N

D (

B L

A C

K )

P T

U _

R S

4 8

5 _

T X

+ (

B R

O W

N )

P T

U _

R S

4 8

5 _

T X-

( R

E D

)

P T

U _

R S

4 8

5 _

R X

+ (

W H

IT E

)

1

13

C H

A S

S IS

G R

O U

N D

( N

O N

E )

P A

Y L

O A

D S

IG N

A L

6 (

W H

IT E

/P U

R P

L E

)

D IN

M 12

P T

U C

O N

T R

O L

B O

A R

D

26

1

17

3

P A

Y L

O A

D S

IG N

A L

7 (

W H

IT E

/B L

A C

K (

P A

Y L

O A

D S

IG N

A L

1 1

( W

H IT

E /B

L U

E )

P A

Y L

O A

D S

IG N

A L

1 0

( W

H IT

E /B

R O

W N

)

P A

Y L

O A

D S

IG N

A L

5 (

L IG

H T

B L

U E

)

P A

Y L

O A

D S

IG N

A L

9 (

G R

A Y

)

P A

Y L

O A

D S

IG N

A L

3 (

W H

IT E

/Y E

L L

O W

)

P A

Y L

O A

D S

IG N

A L

8 (

W H

IT E

/G R

A Y

)

P A

Y L

O A

D S

IG N

A L

4 (

B L

A C

K /B

L U

E )

P A

Y L

O A

D S

IG N

A L

1 (

Y E

L L

O W

/G R

E E

N )

P A

Y L

O A

D S

IG N

A L

2 (

B L

A C

K /R

E D

)

2

5

22

P T

U _

R S

4 8

5 _

R X-

( Y

E L

L O

W )

Copyright 2018, FLIR Commercial Systems, Inc. A-5

PTU-5 User Manual

This page intentionally left blank.

Copyright 2018, FLIR Commercial Systems, Inc.A-6

B - Mechanical Drawings

The drawings in this Appendix describes the payload mounting patterns for the different brackets and displays the PTU dimensions.

6.17 156.8

2.56 65.0

6.11

155.2

3.84 97.6

5.00 127.0

4.37 110.9

2.68 68.0

Copyright 2018, FLIR Commercial Systems, Inc. B-1

PTU-5 User Manual

6.82 173.3

3.42 86.9

.26 6.5

2.94 74.8

TYP .39

10.0

1/4-20 UNC THRU

.94

24.0

.08 R2.0

2.44 62.0

.73

18.5

TOP MOUNT BRACKET CONFIGURATION

Copyright 2018, FLIR Commercial Systems, Inc.B-2

Appendix B: Mechanical Drawings

2.43 61.6

2.28 58.0

.26 6.5

1.45 36.9

1.44 36.5

1.57 40.0

.39 10.0 TYP

1.18 30.0

.08 R2.0

1/4-20 UNC THRU

SIDE MOUNT BRACKET CONFIGURATION

Copyright 2018, FLIR Commercial Systems, Inc. B-3

PTU-5 User Manual

This page intentionally left blank.

Copyright 2018, FLIR Commercial Systems, Inc.B-4

C - Networking

This section describes the basic installation and setup steps required to network your pan-tilt units.

C.1 - Ethernet To connect multiple PTU units to a single host computer via Ethernet:

1. Plan the physical placement of each PTU and the host computer.

2. Connect each PTU to your network using the Ethernet connection on each unit.

3. On the host computer, run the PTU Finder utility to locate the PTU IP addresses.

4. Launch a Web browser and point it to the IP address of the unit you want to connect to. You may open multiple browser windows/tabs to connect to multiple units at once.

Please see Ethernet Connection on page 11 for more information about connecting to a PTU using the Web interface.

C.2 - Serial You may connect up to 127 PTUs to a single host computer port. The host computer can then address each connected PTU as if it were the only unit on the network. This makes it easy to migrate code developed for a single PTU to a network of PTUs controlled by one host computer.

To connect multiple PTU units to a single host computer via serial:

1. Assign a unique network ID number to each PTU.

2. Connect the PTU units and host computer to the serial network.

3. Test the configuration by addressing each PTU by its unit ID and issuing commands and queries, such as:

- PS - pan speed setting

- TS - tilt speed setting

- PD - current pan speed

- TD - current tilt speed

Copyright 2018, FLIR Commercial Systems, Inc. C-1

PTU-5 User Manual

C.2.1 - Serial Networking Connections

Multiple PTUs can be networked and connected to the host computers RS-232 port. All network communications use RS-485, meaning that you must have an RS-232 to RS-485 adapter if the host computer does not directly support full-duplex RS-485 I/O. The host computer functions as the network host, meaning that its TX and RX lines define the directions of data traffic flow. Each PTU on the network is a client that communicates with the host using a full-duplex connection.

Figure C-1: PTU Network Configuration

When making your own data cables, FLIR Systems, Inc. recommends using a good quality twisted pair cable with about 100 impedance, which provides good noise immunity for RS-485 connections.

The following RS-232 to RS-485 converters are recommended:

ATEN IC-485S

Moxa A50

Both adapters require a flipped RJ-12 connector (such as a standard phone cord).

Terminate the serial network by placing 120 1% resistors between the RS-485 Transmit+/Transmit- (Tx+/Tx-) and Receive+/Receive- (Rx+/Rx-) wires at each end of the network, as shown in Figure C-1.

RS-232<->RS-485 or

USB<->RS-485 Converter

Host

RS-232 or USB

xRxTxRxTxRxTxRxT 584-SR584-SR584-SR584-SR

RS-485 Multi-Drop TX Twisted Pair

RS-485 Multi-Drop RX Twisted Pair

120 1%

120 1%

120 1%

120 1%

Copyright 2018, FLIR Commercial Systems, Inc.C-2

Appendix C: Networking

C.2.2 - ASCII Command Syntax

This section provides a brief overview of the ASCII command syntax. Please refer to the Pan-Tilt E Series Command Reference Manual for complete information and instructions.

The PTU uses both commands and queries. A command tells the PTU to do something (such as pan to a specific angle). A query asks the PTU to return the requested value (such as reporting the current pan angle).

The basic ASCII command syntax is , where:

is the actual command (such as PP for pan position),

is a numerical value (such as the desired pan position), and

is a character used to denote the end of a command. Valid delimiter characters can be either [SPACE] or [ENTER].

The basic ASCII query syntax is , where:

is the actual command (such as PP for pan position),

is a character used to denote the end of a query. Valid delimiter characters can be either [SPACE] or [ENTER].

For example:

Command: PP sets the desired absolute pan position.

Query: PP returns the current absolute pan position.

Commands and queries return results that display on the terminal screen, as follows:

A successfully executed command displays * on the terminal screen.

A successfully executed query displays (where is the result of the query you just executed).

A failed command displays! (where describes the error encountered).

A pan axis limit hit asynchronously displays !P.

A tilt axis limit hit asynchronously displays !T.

This sample command sequence pans the PTU-E46 to the left, waits, and then pans it back to the right:

S PP-2500 * A * PP * Current Pan position is -2500 PP2500 * A * PP * Current Pan position is 2500

Copyright 2018, FLIR Commercial Systems, Inc. C-3

PTU-5 User Manual

C.2.3 - Serial Command List

These tables list the most commonly used serial commands. Please refer to the Pan-Tilt E Series Command Reference Manual for complete information about the available commands and their usage.

LIMITS

POSITION

SPEED

MISCELLANEOUS

CMD DESCRIPTION CMD DESCRIPTION

PN Minimum pan position L Query limit status

PX Maximum pan position LE Enable limits

TN Minimum tilt position LD Disable limits

TX Maximum tilt position LU User limits

CMD DESCRIPTION CMD DESCRIPTION

PP Pan position PR Pan resolution

TP Tilt position TR Tilt resolution

PO Pan offset

TO Tilt offset

CMD DESCRIPTION CMD DESCRIPTION CMD DESCRIPTION

PS Pan speed PA Pan acceleration PU Pan upper speed

TS Tilt speed TA Tilt acceleration PL Pan lower speed

PD Pan speed offset PB Pan base speed TU Tilt upper speed

TD Tilt speed offset TB Tilt base speed TL Tilt lower speed

CMD DESCRIPTION

A Await

R Reset

DF Restore factory defaults

DS Default save

DR Restore saved settings

H Halt

O Returns the PTU temperature.

MC Monitor Cycles Since Boot

Copyright 2018, FLIR Commercial Systems, Inc.C-4

D - Troubleshooting

This appendix presents common mechanical, power, and networking challenges and resolutions, and also provides information about contacting FLIR Technical Support.

D.1 - Mechanical After powering on, the PTU stops moving with a grinding noise.

If you have a payload attached:

- The payload may be too heavy. Try moving the payload closer to the center of rotation of the affected axis and/or reducing the payload weight.

- The movement settings may be too aggressive. Reduce the upper speed limit and/or accelera- tion.

If you do not have a payload attached, contact FLIR Technical Support.

D.2 - Power The PTU-5 reset movements are different than other PTU models.

This is normal behavior; the PTO does not return to 0,0.

D.3 - Networking Unable to determine the PTU IP address to access the onboard Web page.

If you are running Windows, use the PTU Finder tool included on the CD that shipped with your PTU.

If you are not running Windows, attach a serial device to the PTU host port and then issue the NI command to query the IP address of the PTU.

PTU-E46 Web page controls are sluggish.

Adjust the speeds and/or step size by clicking the Set Arrow Step Size or Set Arrow Speed headers in the PTU Control Web page, as described in the Pan-Tilt E Series Command Reference Manual.

Try closing other programs on your computer to free up resources.

Copyright 2018, FLIR Commercial Systems, Inc. C-1

PTU-5 User Manual

Unable to establish serial communications with the PTU.

If you are using RS-485:

- Try using a null-modem adapter.

- If you are using a laptop, make sure that it is plugged in. RS-485 will not work if the PTU and host computer grounds are too far apart.

If you are using the USB to RS-485 adapter provided by FLIR Systems, Inc:

- Make sure the adapter is powered.

- Try using a null-modem adapter.

- If you are using a laptop, make sure that it is plugged in. RS-485 will not work if the PTU and host computer grounds are too far apart.

D.4 - Technical Support FLIR Systems, Inc. provides a range of technical support options:

Email: MCS-Support@flir.com

Web: www.FLIR.com/MCS

Phone: (888)747-3547

The preferred method of contacting Technical Support is via email, which helps ensure proper dispatching and tracking to address your questions promptly.

When contacting Technical Support, please provide the following information:

PTU model and configuration

Payload (Please include photos, if possible.)

Parameter settings

Description of issue/symptoms

Copyright 2018, FLIR Commercial Systems, Inc.C-2

E - Regulatory & Warranty Information

E.1 - Regulatory Information Electromagnetic Interference (EMI) is any signal or emission, either radiated in free space or conducted along power or signal leads, that endangers the function of a radio navigation or other safety service or that seriously degrades, obstructs, or repeatedly interrupts a licensed radio communications service.

Class A

Class A equipment has been tested and found to comply with the limits for a Class A digital device, pur- suant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/her own expense.

FLIR PTUs using a cable length of 7 or less, and using the PT-PS-INT30V power supply have been tested to comply with FCC Class A requirements. Full compliance in systems using a 3 motor cable requires an external direct connection from either the controller or the PTU head to earth ground.

Caution: Changes or modifications of this equipment not expressly approved by manufacturer could result in violation of Part 15 of the Federal Communication Commissions rules. The FCC has prepared the following booklet: How to Identify and Resolve Radio-TV Interference Problems. It is available from the US Government Printing Office, Washington DC, 20402. Stock Number 004-00-00345-4.

FCC Notice

According to 47CFR, Parts 2 and 15, Subpart B Class A:

This device complies with FCC Part 15, Subpart B Class A of the FCC Rules. Operation is subject to the fol- lowing two conditions: (1) This device may not cause harmful interference, (2) This device must accept any interference received including interference that may cause undesired operations.

CE Notice

This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

Copyright 2018, FLIR Commercial Systems, Inc. C-1

E.2 - About FLIR Systems, Inc. FLIR Systems, Inc. is the worlds largest commercial infrared company with the more high quality thermal night vision systems in the field than all other manufacturers combined. Our rugged, stabi- lized imagers are on thousands of civil and military surface and airborne platforms in the USA and around the world.

With thousands of our thermal cameras on the job in military, scientific, law enforcement, and secu- rity applications, FLIR brings an unmatched level of experience and dedication to the creation of cut- ting edge thermal night vision systems.

We design and manufacture all of the critical technologies inside our products, including detectors, electronics, special lenses, and pan/tilt motion control systems. All of our products are proudly assembled right here in the USA.

For additional technical information, or to see a demonstration of these revolutionary thermal night vision systems, contact a FLIR representative today. You can also visit www.FLIR.com to watch prod- uct videos and see how thermal imaging can help you see night and day.

In 1992, FLIR MCS (formerly Directed Perception) created one of the first miniature computer-con- trolled pan/tilt tracking mounts and continues to lead the field in innovation, applied design, and service. Our patented pant/tilt units are in use in a wide range of industries including security and surveillance, industrial automation, robotics, communications, military/aerospace, law enforce- ment, education, R&D, webcams, and teleconferencing/distance learning applications. Some of the payloads that can be precisely controlled include sensors like video cameras, thermal imagers, laser rangefinders, microwave antennas, and many more. FLIR MCS maintains engineering capabilities in mechanical design, electronics, and embedded and network software development. Find out more at www.FLIR.com/mcs.

Appendix E: Regulatory Information

E.3 - Limited Warranty FLIR warrants that the Goods, at Delivery and for 365 days (Warranty Period), will conform to published specifications and be free from defects in materials, unless another Warranty Period is stated on the Front of the Acknowledgment. Buyer shall report any claimed defect in writing to FLIR promptly upon discovery and within

the Warranty Period. FLIR shall elect either to repair or replace nonconforming Goods at the appropriate FLIR service center nearest to Buyer (Remedy).

This warranty does not extend to: (a) Goods repaired or modified in any manner by persons other than FLIR or FLIR's authorized designee; and (b) Goods that are defective due either to normal wear and tear, or Buyer's failure to properly store, install, operate or maintain the Goods. The Remedy is FLIR's sole obligation, and Buyer's exclusive recourse, for all claims of defects with respect to the Goods.

If the Remedy is adjudicated insufficient, however, FLIR shall refund the Price paid without further liabil- ity to Buyer relating to the subject Goods. Buyer shall pay costs of returning Goods under a warranty claim, and FLIR shall pay the costs of sending Goods to Buyer after the Remedy is performed. SELLER MAKES NO OTHER WARRANTY OF ANY KIND WITH RESPECT TO THE GOODS OR SERVICES.

ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO, IMPLIED WARRAN- TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, and NONINFRINGEMENT ARE HEREBY DISCLAIMED.

Copyright 2018, FLIR Commercial Systems, Inc. C-3

Manualsnet FAQs

If you want to find out how the Pan-Tilt Unit v3.01 Flir works, you can view and download the Flir Pan-Tilt Unit v3.01 Computer Controlled Unit User Manual on the Manualsnet website.

Yes, we have the User Manual for Flir Pan-Tilt Unit v3.01 as well as other Flir manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User Manual should include all the details that are needed to use a Flir Pan-Tilt Unit v3.01. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Flir Pan-Tilt Unit v3.01 Computer Controlled Unit User Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Flir Pan-Tilt Unit v3.01 Computer Controlled Unit User Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Flir Pan-Tilt Unit v3.01 Computer Controlled Unit User Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Flir Pan-Tilt Unit v3.01 Computer Controlled Unit User Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Flir Pan-Tilt Unit v3.01 Computer Controlled Unit User Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.