USER GUIDE

Current Calibrator

Model PRC10

2 PRC10-EU-EN-V1.2 01.13

Introduction

Thank you for selecting the Extech Model PRC10. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit the Extech Instruments website (www.extech.com) to check for the latest version of this User Guide. Extech Instruments is an ISO-9001 certified company.

Safety

International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present

Double insulation

Safety Notes

Do not exceed the maximum allowable input range.

Turn the unit OFF when the device is not in use.

Remove the batteries if the device is to be stored for longer than 60 days.

Never dispose of batteries in a fire. Batteries may explode or leak.

Never mix battery types. Always install new batteries of the same type.

Cautions

Improper use of this meter can cause damage, shock, injury or death. Read and understand this user manual before operating the meter.

Always remove the test leads before replacing the battery.

Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair or replace any damage before use.

If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

3 PRC10-EU-EN-V1.2 01.13

Meter Description

1. AC adaptor input jack

2. Display

3. Power ON/OFF

4. Source output adjustment arrow buttons

5. Set button

6. Unit button (mA or %)

7. I/O MODE button

8. MEM (memory STEP button)

9. Backlight/ZERO button

10. Test lead inputs

Display Layout

1. SOURCE mode icon

2. ZERO function status icon

3. MEASURE mode icon

4. Loop Power icon

5. Auto Power OFF active icon

6. Battery status icon

7. Measure mode value

8. Measure mode units icon

9. Datalogger memory location

10. Source mode value

11. Source mode units icon

3

4

5

6

7

8

10

9

2

1

4 PRC10-EU-EN-V1.2 01.13

Keypad Descriptions and Operation

POWER BUTTON and AUTO POWER OFF FEATURE

1. Use the POWER button to turn the unit ON or OFF. When the unit is powered up, a short self-test will ensue after which the display will stabilize.

2. When the battery symbol flashes on the display, replace the battery as soon as possible. Low battery power may cause inaccurate readings and erratic meter operation.

3. This instrument is equipped with Auto Power OFF which turns the meter off after 10 minutes of inactivity. To override this feature; press and hold the POWER button until the display icon ATP turns off.

UNIT BUTTON

Press the UNIT button to select mA or % units.

I/O BUTTON

Momentarily press the I/O button to select either SOURCE (output) or MEASURE (input).

MODE BUTTON (Loop Power)

In the MEASURE mode, Press and Hold the MODE (I/O) button for 1 seconds to turn loop power on or off.

(Backlight) BUTTON

Momentarily press the Backlight button to turn the backlight on or off.

ZERO ( ) BUTTON

In the MEASURE or SOURCE mode, Press and Hold the ZERO ( ) button for 1 seconds to zero the meter.

and BUTTONS

The arrow buttons are used to set the output value in the SOURCE mode.

1. Select the SOURCE mode

2. Press the or button select a digit for adjustment. The blinking underline curser identifies the digit selected.

3. Press the or button to adjust the value of the digit. Press and Hold the or button to rapidly adjust the value.

5 PRC10-EU-EN-V1.2 01.13

SET BUTTON

The SET button is used to manually step through the 5 stored output values.

1. Select the SOURCE mode

2. Press the SET button and the value stored in memory location 01 will be sourced. MEM.01 appears in the display.

3. Each press of the SET button will step through the 5 memory locations.

4. The arrow buttons can be used to adjust the value in each memory location.

STEP/MEM BUTTON

The STEP/MEM button is used to automatically step through the 5 stored output values. The meter can be set for a single cycle of the stored values or a continuous cycle.

1. Select the SOURCE mode

2. Press and HOLD the STEP/MEM button. STEPSS (single cycle) and STEPSC (continuous cycle) will alternately appear in the display. Release the button when the desired mode is displayed.

3. In single cycle mode the meter will source the current displayed in MEM01 for 5 seconds. The meter will then advance to MEM02 for 5 seconds. This will continue through MEM05 and then step down through the memory locations. The cycle will end when MEM01 has been reached.

4. In the continuous mode the cycle will continue until manually stopped.

5. Momentarily press the STEP/MEM button to stop the cycle. END will briefly appear in the display.

STORING VALUES INTO MEMORY

The default values stored in the memory locations are:

Memory Location

mA %

M1 4.00mA 0.0%

M2 8.00mA 25%

M3 12.00mA 50%

M4 16.00mA 75%

M5 20.00mA 100%

To change the values in memory:

1. Select the SOURCE mode

2. Press the SET button to select the memory location to be changed.

3. Press the arrow buttons to adjust to the new value

4. Momentarily press the MEM button to store the value. The memory location icon will blink while the value is being stored.

6 PRC10-EU-EN-V1.2 01.13

Modes of Operation

MEASURE (Input) Mode of Operation

In this mode, the unit will measure up to 50mADC.

1. Turn the meter ON.

2. MEASURE will appear in the display.

3. Press the UNIT button to select mA or %

4. Press and HOLD the MODE-I/O button for 2 seconds if 24V loop power is required. Lp.POWER will appear in the display.

5. Connect the Calibration Cable to the meter.

6. Connect the Calibration Cable to the device or circuit under test.

7. Read the measurement on the LCD display.

SOURCE (Output) Mode of Operation

In this mode, the unit can source current up to 24mADC at 1000 ohms. The current can be output either manually or stepped from memory as described earlier.

1. Turn the meter ON

2. Press the I/O button to select SOURCE.

3. Use the UNIT button to select % or mA.

4. Connect the Calibration Cable to the meter

5. Connect the Calibration Cable to the device or circuit under test

6. Use the arrow buttons to set the desired output value in the lower display. The upper display indicates the actual current value being sourced. If the upper display does not match the set value, either the batteries need to be replaced or the load impedance is beyond the specified range.

7 PRC10-EU-EN-V1.2 01.13

Tilt Stand / Hanger

The rear stand is provides two methods for convenience in viewing.

1. Pull the bottom portion of the stand out to place the unit on a flat surface for viewing.

2. Pull the bottom and top portions of the stand out, and then rotate the stand to allow the unit to be hung.

Battery Replacement

When the battery icon appears on the display, the six AA batteries must be replaced.

The battery compartment is located on the rear of the meter.

1. Open the tilt stand, loosen the captive Philips head screw and remove the battery cover.

2. Remove and replace the batteries, observing polarity.

3. Replace and secure the battery cover.

All EU users are legally bound by the Battery Ordinance to return all used batteries to community collection points or wherever batteries / accumulators are sold.

Disposal in household trash or refuse is prohibited.

Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle

Battery Safety Reminders

Please dispose of batteries responsibly; always observe local, state, and federal regulations with regard to battery disposal.

Never dispose of batteries in a fire. Batteries may explode or leak.

Never mix battery types or old and new batteries. Always install new batteries of the same type.

8 PRC10-EU-EN-V1.2 01.13

Specifications

General Specifications

Display Dot matrix LCD

Maximum Load 1000 ohms @ 24mA

Meter Power 6 AA batteries or AC adaptor

Auto Power OFF Meter automatically powers off after 10 minutes of inactivity

Current output capability 24mADC at 1000 ohms

Operating Temperature 41F to 104F (5C to 40C)

Storage Temperature - 4oF to 140oF (-20oC to 60oC)

Operating Humidity Max 80% up to 87F (31C) decreasing linearly to 50% at 104F (40C)

Storage Humidity <80%

Operating Altitude 7000ft (2000meters) maximum

Dimensions 159 x 80 x 44 mm (6.3 x 3.2 x 1.7")

Weight 232g (8.2 oz.) without batteries

Range Specifications

Mode Function Range (Resolution) Accuracy (% of reading)

Current 0 to 50mA (0.01mA) Measure

Percent (%) -25% to +230% (0.1%)

Current 0 to 24mA (0.01mA) Source

Percent (%) -25% to +125% (0.1%)

(0.01% + 1 digit)

Power Loop Power 24 to 30VDC, <50mA

Manualsnet FAQs

If you want to find out how the Extech Flir works, you can view and download the Flir Extech PRC10 Calibrator User Guide on the Manualsnet website.

Yes, we have the User Guide for Flir Extech as well as other Flir manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User Guide should include all the details that are needed to use a Flir Extech. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Flir Extech PRC10 Calibrator User Guide is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Flir Extech PRC10 Calibrator User Guide consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Flir Extech PRC10 Calibrator User Guide free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Flir Extech PRC10 Calibrator User Guide, simply download the document to your computer. Once downloaded, open the PDF file and print the Flir Extech PRC10 Calibrator User Guide as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.