THE OUTER CASING, FRONT AND GLASS PANEL BECOME EXTREMELY HOT DURING OPERATION AND WILL RESULT IN SERIOUS INJURY AND BURNS IF TOUCHED. IT IS THEREFORE RECOMMENDED THAT A

FIREGUARD COMPLYING WITH BS 8423 (LATEST EDITION) IS USED IN THE PRESENCE OF YOUNG CHILDREN, THE ELDERLY OR INFIRM.

This product contains a heat resistant glass panel. This panel should be checked during Installation and at each servicing interval. If any

damage is observed on the front face of the glass panel (scratches, scores, cracks or other surface defects), the glass panel must be replaced and the appliance must not be used until a replacement is installed. Under no circumstances should the appliance be used if any

damage is observed, the glass panel is removed or broken.

It is essential that ALL of the screws that retain the glass frame are replaced and tightened correctly. Under no circumstances should the appliance be operated if any of these screws are loose or missing.

These Instructions must be left with the appliance for future reference and for consultation when servicing the appliance. Please make the

customer aware of the correct operation of the appliance before leaving these instructions with them.

The commissioning sheet found on Page 3 of this Instruction manual must be completed by the Installer prior to leaving the premises.

IMPORTANT

2

Appliance Commissioning Checklist ......................3

User Instructions .......................................................4

Installation Instructions ............................................9

Technical Specifications ............................................................. 9

Site Requirements .................................................................... 11

Installation ................................................................................13

Commissioning .........................................................................18

Servicing Requirements .........................................19

Fault Finding .............................................................................19

How to replace parts ................................................................21

Basic spare parts list ................................................................27

Service Records ......................................................................30

Information Requirement - Gas Heaters ................................31

Covering the following models:

Contents

Model NATURAL GAS LPG

Black DV541-010 DV541-409 Ivory Enamel DV541-042 DV541-440 White Ivory Enamel DV541-034 DV541-451 Black Enamel DV541-093 DV541-456 Majolica Brown DV541-116 DV541-475

It is a requirement of the Building Regulations 2010 that the installation of this appliance is notified to the Local Authority. It is the responsibility of the GasSafe registered installer to carry out this notification to the Local Authority via the GasSafe register Competent Persons Scheme in England and Wales (different rules apply in Scotland and Northern Ireland).

When the installation has been notified, GasSafe will send a Building Regulations Compliance Certificate to you containing details of the work completed. Please ensure that the person responsible for the installation of this appliance completes this notification and records it in the Appliance Commissioning Checklist on page 3.

IT IS YOUR RESPONSIBILITY TO COMPLY WITH THE BUILDING REGULATIONS AND BE ABLE TO PRODUCE THIS CERTIFICATE SHOULD IT BE REQUIRED IN THE FUTURE.

3

IMPORTANT NOTICE Explain the operation of the appliance to the end user, hand the completed instructions to them for safe keeping,

as the information will be required when making any guaranteed claims.

Retailer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Contact No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Date of Purchase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Model No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Serial No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Gas Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation Company . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Engineer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Contact No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

GasSafe Reg No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Date of Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

RETAILER AND INSTALLER INFORMATION

To assist us in any guarantee claim please complete the following information:- Appliance Commissioning Checklist

FLUE CHECK PASS FAIL

1. Flue Is correct for appliance

2. Flue flow Test

3. Spillage Test

GAS CHECK

1. Gas soundness & let by test

2. Standing gas pressure mb

3. Appliance working pressure (on High Setting) NB All other gas appliances must be operating on full mb

4. Gas rate m3/h

5. Does Ventilation meet appliance requirements

6. Have controls been upgraded (Upgradeable models only) 8455 Standard 8456 Programmable Thermostatic and Timer

YES NO

YES NO

SAFETY CHECK

1. Glass checked to ensure no damage, scratches, scores or cracks.

2. Door secured correctly and all screws replaced

BUILDING CONTROL NOTIFICATION YES NO

1. Installer notified GasSafe/Local Authority of installation via Competent Persons Scheme?

4

Welcome

Congratulations on purchasing your Dovre 280 stove, if installed correctly Dovre hope it will give you many years of warmth and pleasure for which it was designed.

The purpose of this manual is to familiarise you with your appliance, and give guidelines for its installation, operation and maintenance. If, after reading, you need further information, please do not hesitate to contact your Dovre retailer.

WARNING

In the event of a gas escape or if you can smell gas, please take the following steps:

Immediately turn off the gas supply at the meter/emergency control valve

Extinguish all sources of ignition

Do not smoke

Do not operate any electrical light or power switches (On or Off)

Ventilate the building(s) by opening doors and windows

Ensure access to the premises can be made

Please report the incident immediately to the National Gas Emergency Service Call Centre on 0800 111 999 (England, Scotland and Wales) , 0800 002 001 (N. Ireland) or in the case of LPG, the gas supplier whose details can be found on the bulk storage vessel or cylinder.

The gas supply must not be used until remedial action has been taken to correct the defect and the installation has been recommissioned by a competent person.

1. General

1.1 Installation and servicing must only be carried out by a competent person whose name appears on the GasSafe register. To ensure the engineer is registered with GasSafe they should possess an ID Card carrying the following logo:

1.2 In all correspondence, please quote the appliance type and serial number, which can be found on the data badge accessed from the rear of the appliance or on the Commissioning Checklist Page 3.

1.3 Do not place curtains above the appliance: You must have 300mm clearance between the appliance

and any curtains at either side.

1.4 The manufacturer considers the full outer casing of this stove to be a working surface and it will become hot whilst in operation. A suitable guard is recommended to protect young children, the aged and the infirm.

1.5 No furnishings or other objects should be placed within 1 metre of the front of the appliance.

1.6 If a shelf is fitted, a distance of 225mm above the appliance is required.

1.7 Do not attempt to burn rubbish in this stove.

1.8 This appliance must only be operated with the door secured firmly in position. If any cracks appear in the glass the appliance must not be used until the glass panel is replaced.

1.9 This product is guaranteed for 2 years from the date of installation, as set out in the terms and conditions of sale between Dovre and your local Dovre retailer. Please consult with your local Dovre retailer if you have any questions. In all correspondence always quote the Model Number and Serial Number.

2. Operating the Appliance 2.1 The control valve is at the foot on the right-hand side of the

appliance. It has two controls, Diagram 1:

1. The right-hand knob controls the pilot ignition. 2. The left-hand knob controls the main burner.

1

2.2 Refer to separate instructions if your appliance is upgraded to include battery remote control. The instructions below apply whether or not you have the remote upgrade.

Lighting the Pilot

2.3 To start the left-hand and right-hand control knobs must both point to off ( ):

2.4 Press in the right-hand control knob and rotate anti- clockwise until a click is heard. Continue to press in. The knob points to the pilot ( ).

The pilot is lit.

2.5 Keep the knob depressed for 10 seconds before releasing. The pilot remains lit.

Repeat the above steps if the pilot does not stay lit.

NOTE: If the pilot goes out, the Interlock system prevents you lighting again for a short period.

2.6 If, after repeating the above steps the pilot does not light, contact your Retailer or Installer.

2.7 Turn the right-hand knob to the left to main burner setting ( ).

User Instructions

5

User Instructions Adjusting the Flame height

2.8 You can now adjust the flame height and temperature using the left-hand control knob.

2.9 Turn the left-hand knob anti-clockwise to increase the flame height.

2.10 Turn clockwise to decrease the height.

IMPORTANT: YELLOW FLAMES TYPICALLY APPEAR WHEN THE APPLIANCE HAS REACHED NORMAL OPERATING TEMPERATURE. THIS CAN TAKE UP TO 30 MINUTES.

WARNING: IF THE APPLIANCE FAILS TO LIGHT OR BECOMES EXTINGUISHED IN USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO RELIGHT.

3. Turning OFF the Appliance

3.1 To turn the main burner off turn the left-hand knob until it points to off ( ). Just the pilot remains lit.

3.2 Press in and turn the right-hand knob until it points to off ( ). The pilot goes out.

4. Upgrading the Appliance

4.1 The appliance is fitted with a control valve that can easily be upgraded to battery powered remote control.

There are two versions of this control which can be obtained through your local Dovre retailer.

There is no requirement for this upgrade to be carried out by an approved GasSafe engineer. However Dovre recommend that this task is undertaken by a suitably competent person.

4.2 This upgrade can be fitted before or after installation but if side clearances are limited then it will be easier to upgrade the appliance before installation. Full instructions are included with the kit.

Standard Remote Control (PART NUMBER 8455)

4.3 This remote control can control the gas appliance after the pilot has been lit. It can turn the main burner on and regulate it from low through to high and back again. It can turn the main burner off leaving the pilot burning.

Thermostatic and Timer Remote Control (PART NUMBER 8456)

4.4 This remote control can control the gas appliance after the pilot has been lit.

MANUAL MODE

Can be used to turn the main burner on and manually regulate it from low through to high and back again. It can also be used to turn the main burner off leaving the pilot burning.

AUTO MODE

Will automatically regulate the room to a pre-set temperature.

TIMER MODE

Will turn the appliance on and off according to a pre-set programme and automatically regulate the room temperature during the two on periods.

5. Cleaning the Appliance

WARNING: NEVER CLEAN THE APPLIANCE WHILE ITS HOT. THE APPLIANCE STAYS HOT FOR A LONG TIME AFTER SHUTDOWN.

IMPORTANT: THE OUTER PANELLING OF THE APPLIANCE IS MADE FROM CAST IRON. USE CAUTION WHEN INSTALLING, REMOVING AND STORING AS THE COMPONENTS ARE HEAVY AND SHOULD BE HANDLED CAREFULLY.

5.1 Make sure the appliance and surrounds are cool before cleaning.

REMOVING THE DOOR

5.2 For rear flue exit lift the top of the appliance off and put to one side.

5.3 For top flue exit lift and support the top to give clearance, see Diagram 2.

2

5.4 Lift the front upwards until it is clear of the slots and pull away from the appliance, see Diagram 3.

3

6

5.5 Remove the glass frame by undoing the fixing screws and lifting clear, see Diagram 4. Take care to support the glass window panel when removing the screws.

5.6 Place carefully to one side.

4

5.7 Lift out the log guard.

5.8 Carefully remove the ceramic fuel bed components and set aside. Protect the floor coverings and follow the advice given in Section 6.

5.9 The logs do not require cleaning. Do not use a vacuum cleaner or brush to clean the coals, any large pieces of debris can be removed by hand.

5.10 Ensure any debris is removed from the burner ports.

5.11 Replace the ceramics, see Section 6.

5.12 Ensure that the rope seal on the back of the glass frame is intact and replace the screws working from the top down. Tighten the screws evenly DO NOT OVER TIGHTEN, see Diagram 4.

5.13 Replace ALL of the securing screws ensuring that a screw is present in all fixing slots.

UNDER NO CIRCUMSTANCES SHOULD THE APPLIANCE BE USED IF ANY OF THE FRAME RETAINING SCREWS ARE LOOSE OR MISSING.

5.14 With the top still supported or removed refit front by locating in grooves and lowering into place, see Diagram 3.

5.15 Replace top, see Diagram 2.

NEVER OPERATE THE APPLIANCE WHEN THE GLASS FRAME IS REMOVED, OR THE GLASS IS BROKEN.

5.16 Use a damp cloth to clean the outer casing of the appliance.

User Instructions 6. Arrangement of Fuel Bed

Advice on handling and disposal of fire ceramics

The fuel effect of this appliance is made from Refractory Ceramic Fibre (RCF), a material which is commonly used for this application.

Protective clothing is not required when handling these articles, but we recommend you follow normal hygiene rules of not smoking, eating or drinking in the work area and always wash your hands before eating or drinking.

To ensure that the release of RCF fibres are kept to a minimum, during installation and servicing a HEPA filtered vacuum is recommended to remove any dust accumulated in and around the appliance before and after working on it. When servicing the appliance it is recommended that the replaced items are not broken up, but are sealed within heavy duty polythene bags and labelled as RCF waste.

RCF waste is classed as stable, non-reactive hazardous waste and may be disposed of at a licensed landfill site.

Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract; wash hands thoroughly after handling the material.

7. Log Layout

LOGS MUST BE POSITIONED ACCORDING TO THE FOLLOWING INSTRUCTIONS TO GIVE THE CORRECT FLAME EFFECT

7.1 Ensure the burner tray is clean and free from any debris, see Diagram 5.

5

The three logs that make up the fuel bed are visually distinct and fit into specific parts on the burner tray.

7

User Instructions 7.2 Place the rear log into position between the rear brackets

and pushed up against the back panel, see Diagram 6.

Log 1

6

7.3 Place the second log into the left hand groove on the burner tray, see Diagram 7.

The log should butt up against the raised molding and the left hand side liner.

Log 2

7

7.4 Place the third log into the groove on the right hand side, see Diagram 8.

The log should butt up against the raised molding and the right hand side liner.

Log 3

8

7.5 Once the logs are in there are two embers which can be loosely placed at the front of the fuel bed and cover the tabs securing the burner tray, see Diagram 9.

Embers

9

7.6 Sparingly spread an amount of the Embaglow fibres provided, covering the ports in the burner tray., see Diagram 10.

It is essential to cover the port in the middle of the burner tray in order to get the most visually appealing flame picture.

Take care not to use more than half a packet per application.

It is essential to cover the

central port

Embaglow

10

7.7 Fix log guard into position, see Diagram 11.

11

8

The glass frame must be refitted to the appliance following cleaning or servicing.

7.8 Ensure that the rope seal on the back of the glass frame is intact and replace the screws working from the top down. Tighten the screws evenly DO NOT OVER TIGHTEN, see Diagram 12.

12

7.9 Replace ALL of the securing screws ensuring that a screw is present in all fixing slots.

UNDER NO CIRCUMSTANCES SHOULD THE APPLIANCE BE USED IF ANY OF THE FRAME RETAINING SCREWS ARE LOOSE OR MISSING.

NEVER OPERATE THE APPLIANCE WHEN THE GLASS FRAME IS REMOVED, OR THE GLASS IS BROKEN.

7.10 With the top still supported or removed refit front by locating in grooves and lowering into place, see Diagram 13.

13

7.11 Now replace top, see Diagram 14.

14

User Instructions 8. Flue Sure System

8.1 The appliance is fitted with a Flue Sure System, which will act to cut off the gas supply to the burners in the event of incorrect operation of the flue. If the system acts to cut off the gas supply, this indicates that there is insufficient flue pull. If this occurs a minimum of 10 minutes should be allowed before trying to relight.

Continued operation of this safety device means there may be a serious problem with the flue system. A qualified GasSafe engineer should inspect this.

DO NOT USE THE APPLIANCE UNTIL AN ENGINEER SAYS IT IS SAFE TO DO SO.

9. Flame Failure Device 9.1 This is a safety feature incorporated on this appliance which

automatically switches off the gas supply if the pilot goes out and fails to heat the thermocouple.

IF THIS OCCURS DO NOT ATTEMPT TO RELIGHT THE APPLIANCE FOR 3 MINUTES.

10. Running In 10.1 During initial use of a new Dovre appliance a strong odour

will be encountered as various surface coatings become hot for the first time. Although these odours are harmless it is recommended that the appliance is operated on maximum for 4 to 8 hours in order to fully burn off these coatings. After this period the odours should then disappear.

If the odours persists, please contact your installer for advice.

10.2 During the first few hours of burning there may be discolouration of the flames. This will also disappear after a short period of use.

11. Servicing 11.1 The appliance must be serviced every 12 months by a

qualified GasSafe Engineer. In all correspondence always quote the Model number and the Serial number which may be found on the Commissioning Checklist (Page 3).

12. Ventilation 12.1 Any purpose provided ventilation should be checked

periodically to ensure that it is free from obstruction.

13. Installation Details 13.1 Your installer should have completed the commissioning

sheet at the front of this book. This records the essential installation details of the appliance. In all correspondence always quote the Model number and Serial number.

14. Hot Surfaces 14.1 Parts of this appliance become hot during normal use. Regard all parts of the appliance as a working surface.

14.2 Provide a suitable fire guard to protect young children and the infirm.

9

Installation Instructions Technical Specification

Covering the following models:

Model Gas CAT.

Gas Type Working Pressure

Aeration Injector Gas Rate m3/h

Input kW (Gross)

Country

High Low

Dovre 280 I2H Natural (G20) 20mbar 6mm x 6mm 260 0.433 4.55 2.5 GB, IE

I3P Propane (G31) 37mbar 1 x (14mm x 15mm) 102 0.164 4.35 2.5 GB, IE

Efficiency Class 2 - 75% / NOx Class 4 Flue Outlet Size 127mm (5)

Gas Inlet Connection Size 8mm

Minimum flue specification T250 / N2 / O / D / 1 Maximum flue temperature 220C

Model NATURAL GAS LPG

Black DV541-010 DV541-409 Ivory Enamel DV541-042 DV541-440 White Ivory Enamel DV541-034 DV541-451 Black Enamel DV541-093 DV541-456 Majolica Brown DV541-116 DV541-475

The net efficiency of this appliance has been measured as specified in EN613:2001 and the result after conversion to gross using the appropriate factor from Table E4 of SAP 2012 is 69%. The test data has been certified by Kiwa Nederland BV. The gross efficiency value may be used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.

10

This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the translated instructions and in some cases the appliance will require modification. Contact Dovre for further information.

PACKING CHECKLIST

Qty Description Fixing Kit containing:-

1 x Appliance 1 x Flue Infill Plate 1 x Log Set 1 x Packet of Embaglow

1 x Instruction Manual

Installation Instructions Technical Specification

38 1

13 8

494

56 0

39 1

35130

30

11

Installation Instructions Site Requirements

1. Flue & Chimney Requirements

1.1 The chimney or flue system must comply with the rules in force, and must be a minimum of 127mm in diameter. (5").

1.2 The minimum flue height for the appliance must be 3 metres (10ft). Any horizontal flue run from the rear outlet must not exceed 100mm from the back of the appliance.

1.3 The chimney or flue must be free from any obstruction. Any damper plates must be removed or secured in the fully open position, and no restrictor plates fitted.

1.4 The chimney must be swept prior to the installation, but it need not be swept if it can be seen the chimney is clean and unobstructed throughout its entire length.

1.5 A5" (127mm) liner must be used if fitting the appliance into an existing brick built chimney.

Larger lined flues can work, but in some instances could cause cold start flue problems resulting in nuisance shutdown. Lined flues above 7" (175mm) are not recommended.

1.6 The European chimney standards now describe chimneys and flues by their temperature, pressure and resistance to corrosion, condensation and fire. To identify the correct flue system, the minimum flue specification is shown in the Technical Specification. Existing chimneys are not covered by this system.

2. Flue Options

A range of Vitreous Enamel Gloss Black flue pipe is available to compliment the Dovre 280. Please contact your Dovre retailer for further information.

3. Gas Supply

THIS APPLIANCE IS INTENDED FOR USE ON A GAS INSTALLATION WITH A GOVERNED METER.

3.1 Before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible.

3.2 Ensure the gas supply delivers the required amount of gas and is in accordance with the rules in force.

3.3 You can use soft copper tubing on the installation and soft soldered joints outside the appliance and below the fire.

3.4 A means of isolating the gas supply to the appliance must be provided independent of any appliance control.

3.5 All supply gas pipes must be purged of any debris that may have entered prior to connection to the appliance.

3.6 The gas supply must be installed in a way that does not restrict the removal of the appliance for servicing and inspection.

4. Ventilation

IMPORTANT: Ensure any national ventilation requirements are taken into account during installation of the appliance.

UK ONLY:

The Dovre 280 has a nominal input not exceeding 7.0kW and does not normally require any additional permanent ventilation.

If however, spillage is detected when commissioning the appliance, there may be insufficient natural ventilation and additional ventilation may be required.

FOR THE REPUBLIC OF IRELAND REFER TO THE RULES IN FORCE FOR VENTILATION REQUIREMENTS.

5. Appliance Location

5.1 Building Regulations state this appliance must stand on a non-combustible hearth that is at least 12mm thick and projects 50mm minimum from the base of the appliance in all directions, however Dovre recommend the hearth extends to the following dimensions, see Diagram 1.

A = 794 B = 451 C = 12

1

5.2 Do not install in a room that contains a bath or shower.

12

Installation Instructions Site Requirements

MINIMUM CLEARANCE

5.3 The appliance is not suitable for installation against a combustible wall. All combustible materials must be removed from behind the appliance.

5.4 Ensure that all minimum clearances to combustible materials are complied with, see Diagrams 2 & 2A.

The specified clearances provide the minimum distance to combustible materials. If the appliance is intended to be installed into a non-combustible opening the clearance to the sides and above the appliance can be reduced. However, it is recommended that the specified clearances are maintained irrespective of the materials used in the construction of the opening to allow adequate air flow and access to controls. The clearance at the rear of the appliance must always be a minimum of 50mm.

150 22 5

794

150

2

2A

5.5 In a non-combustible recess be careful to allow enough clearance at the sides and rear of the appliance to perform spillage tests and reach the controls.

13

Installation Instructions 2. Upgrading the Appliance

2.1 The appliance is fitted with a control valve that can easily be upgraded to battery powered remote control.

There are two versions of this control which can be obtained through your local Dovre retailer.

There is no requirement for this upgrade to be carried out by an approved GasSafe engineer. However Dovre recommend that this task is undertaken by a suitably competent person.

2.2 This upgrade can be fitted before or after installation but if side clearances are limited then it will be easier to upgrade the appliance before installation. Full instructions are included with the kit.

Standard Remote Control (PART NUMBER 8455)

2.3 This remote control can control the gas appliance after the pilot has been lit. It can turn the main burner on and regulate it from low through to high and back again. It can turn the main burner off leaving the pilot burning.

Thermostatic and Timer Remote Control (PART NUMBER 8456)

2.4 This remote control can control the gas appliance after the pilot has been lit.

MANUAL MODE

Can be used to turn the main burner on and manually regulate it from low through to high and back again. It can also be used to turn the main burner off leaving the pilot burning.

AUTO MODE

Will automatically regulate the room to a pre-set temperature.

TIMER MODE

Will turn the appliance on and off according to a pre-set programme and automatically regulate the room temperature during the two on periods.

1. Safety Precautions 1.1 For your own and others safety, you must install this

appliance according to local and national codes of practice. Failure to install the appliance correctly could lead to prosecution. Read these instructions before installing and using this appliance.

1.2 These instructions must be left intact with the user.

1.3 Do not attempt to burn rubbish on this appliance.

1.4 Keep all plastic bags away from young children.

1.5 Do not place any object on or near to the appliance and allow adequate clearance above the appliance.

IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT IN USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO RELIGHT THE APPLIANCE.

1.6 The appliance is fitted with a Flue Sure System, which will act to cut off the gas supply to the burners in the event of incorrect operation of the flue. If the system acts to cut off the gas supply, this indicates that there is insufficient flue pull. If this occurs a minimum of 10 minutes should be allowed before trying to relight. Continued operation of this safety device means there may be a serious problem with the flue system. A qualified GasSafe engineer should inspect this.

1.7 Do not alter or tamper with the Flue Sure System. Use only genuine Dovre replacement parts when servicing the system - refer to the Servicing Section, Replacing Parts.

DO NOT USE THE APPLIANCE UNTIL AN ENGINEER SAYS IT IS SAFE TO DO SO.

IMPORTANT: REFER TO DATA BADGE AND TECHNICAL SPECIFICATION AT THE FRONT OF THE MANUAL TO ENSURE THE APPLIANCE IS CORRECTLY ADJUSTED FOR THE GAS TYPE AND CATEGORY APPLICABLE IN THE COUNTRY OF USE.

FOR DETAILS OF CHANGING BETWEEN GAS TYPES REFER TO SERVICING, SECTION 14, REPLACING PARTS.

Unpacking

1.8 Remove the appliance from its packaging, and check that it is complete and undamaged.

Put the loose ceramic parts to one side so that they are not damaged during installation.

14

3. Installation of the Appliance

3.1 Decide whether to use top or rear flue exit. The appliance is factory built for rear flue exit but it can be

changed to top exit by swapping the flue spigot and blanking plate located on the appliance.

3.2 The flue spigot must be placed in an offset position from the blanking plate to correctly align with the top plate.

3.3 To access the blanking plate lift off the cast top and place carefully to one side.

3.4 Remove the four screws holding the blanking plate to the appliance, see Diagram 1.

Note the two additional holes in the top of the firebox.

1

3.5 With the blanking plate removed there are a two additional holes underneath, see Diagram 2.

2

3.6 Position the flue spigot using the offset holes and the ones previously beneath the blanking plate. Secure the spigot and blanking plate in the new positions, see Diagram 3.

3

Installation Instructions 3.7 Position the appliance ensuring all appropriate clearances

are observed.

3.8 Having run the gas supply to the appliance PURGE THE SUPPLY PIPE.

This is essential to expel any debris that can block the gas controls.

3.9 Connect the gas supply to the 8mm-compression elbow at the right-hand rear corner of the appliance

There is a cutout in the right-hand rear leg to enable a straight connection to the rear of the appliance, see Diagram 4.

4

3.10 The flue system can now be connected to the appliance.

3.11 Ensure all joints are sealed with a fire resistant cement and use a self-tapping screw at the flue spigot joint.

4. Gas Soundness Pressure Check

4.1 Connect a suitable pressure gauge to the test point located on the inlet fitting and turn the gas supply on. Light the appliance and check all gas joints for possible leaks. Turn the appliance to maximum and check that the supply pressure is as stated on the databadge. Turn the gas off and replace the test point screw, turn the gas on and check the test point for leaks.

15

5. Removing the Door

IMPORTANT: THE OUTER PANELLING OF THE APPLIANCE IS MADE FROM CAST IRON. USE CAUTION WHEN INSTALLING, REMOVING AND STORING AS THE COMPONENTS ARE HEAVY AND SHOULD BE HANDLED CAREFULLY.

5.1 For rear flue exit lift the top of the appliance off and put to one side.

5.2 For top flue exit lift and support the top to give clearance, see Diagram 5.

5

5.3 Lift the front upwards until it is clear of the slots and pull away from the appliance, see Diagram 6.

6

5.4 Remove the glass frame by undoing the fixing screws and lifting clear, see Diagram 7. Take care to support the glass window panel when removing the screws.

7

5.5 Place carefully to one side.

6. Arrangement of Fuel Bed

Advice on handling and disposal of fire ceramics

The fuel effect of this appliance is made from Refractory Ceramic Fibre (RCF), a material which is commonly used for this application.

Protective clothing is not required when handling these articles, but we recommend you follow normal hygiene rules of not smoking, eating or drinking in the work area and always wash your hands before eating or drinking.

To ensure that the release of RCF fibres are kept to a minimum, during installation and servicing a HEPA filtered vacuum is recommended to remove any dust accumulated in and around the appliance before and after working on it. When servicing the appliance it is recommended that the replaced items are not broken up, but are sealed within heavy duty polythene bags and labelled as RCF waste.

RCF waste is classed as stable, non-reactive hazardous waste and may be disposed of at a licensed landfill site.

Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract; wash hands thoroughly after handling the material.

7. Log Layout

LOGS MUST BE POSITIONED ACCORDING TO THE FOLLOWING INSTRUCTIONS TO GIVE THE CORRECT FLAME EFFECT

7.1 Ensure the burner tray is clean and free from any debris, see Diagram 8.

8

Installation Instructions

16

Installation Instructions The three logs that make up the fuel bed are visually distinct

and fit into specific parts on the burner tray. 7.2 Place the rear log into position between the rear brackets

and pushed up against the back panel, see Diagram 9.

Log 1

9

7.3 Place the second log into the left hand groove on the burner tray, see Diagram 10.

The log should butt up against the raised molding and the left hand side liner.

Log 2

10

7.4 Place the third log into the groove on the right hand side, see Diagram 11.

The log should butt up against the raised molding and the right hand side liner.

Log 3

11

7.5 Once the logs are in there are two embers which can be loosely placed at the front of the fuel bed and cover the tabs securing the burner tray, see Diagram 12.

Embers

12

7.6 Sparingly spread an amount of the Embaglow fibres provided, covering the ports in the burner tray., see Diagram 13.

It is essential to cover the port in the middle of the burner tray in order to get the most visually appealing flame picture.

NOTE: It is not necessary to use all of the Embaglow.

It is essential to cover the

central port

Embaglow

13

7.7 Fix log guard into position, see Diagram 14.

14

17

Installation Instructions 8. Completion of Assembly

8.1 Ensure that the rope seal on the back of the glass frame is intact and replace the screws working from the top down. Tighten the screws evenly DO NOT OVER TIGHTEN, see Diagram 15.

NEVER OPERATE THE APPLIANCE WHEN THE GLASS FRAME IS REMOVED, OR THE GLASS IS BROKEN.

15

8.2 Replace ALL of the securing screws ensuring that a screw is present in all fixing slots.

UNDER NO CIRCUMSTANCES SHOULD THE APPLIANCE BE USED IF ANY OF THE GLASS FRAME RETAINING SCREWS ARE LOOSE OR MISSING.

8.3 With the top still supported or removed refit front by locating in grooves and lowering into place, see Diagram 16.

16

8.4 Now replace top, see Diagram 17.

17

9. Operating the Appliance 9.1 The control valve is at the foot on the right-hand side of the

appliance. It has two controls, see Diagram 18:

1. The right-hand knob controls the pilot ignition

2. The left-hand knob controls the main burner

18

9.2 Refer to separate instructions if your appliance is upgraded to include battery remote control. The instructions below apply whether or not you have the remote upgrade.

Lighting the Pilot

9.3 To start the left-hand and right-hand control knobs must both point to off ( ):

9.4 Press in the right-hand control knob and rotate anti- clockwise until a click is heard. Continue to press in. The knob points to the pilot ( ).

The pilot is lit.

9.5 Keep the knob depressed for 10 seconds before releasing. The pilot remains lit.

Repeat the above steps if the pilot does not stay lit.

NOTE: If the pilot goes out, the Interlock system prevents you lighting again for a short period.

9.6 If, after repeating the above steps the pilot does not light, contact your Retailer or Installer.

9.7 Turn the right-hand knob to the left to main burner setting ( ).

Adjusting the Flame height

9.8 You can now adjust the flame height and temperature using the left-hand control knob.

9.9 Turn the left-hand knob anti-clockwise to increase the flame height.

9.10 Turn clockwise to decrease the height.

IMPORTANT: YELLOW FLAMES TYPICALLY APPEAR WHEN THE APPLIANCE HAS REACHED NORMAL OPERATING TEMPERATURE. THIS CAN TAKE UP TO 30 MINUTES.

WARNING: IF THE APPLIANCE FAILS TO LIGHT OR BECOMES EXTINGUISHED IN USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO RELIGHT.

18

1. Commissioning

1.1 Close all doors and windows in the room.

1.2 Ignite the appliance and operate on maximum for 10 minutes.

1.3 Position a lighted smoke match just inside the draught diverter opening at the rear of the appliance.

1.4 Check all smoke is drawn into the opening, see Diagram 1.

1 Rear of Appliance

Draft diverter lip

Smoke match

1.5 If there is any doubt, run the appliance for a further 10 min- utes, and repeat the test.

1.6 If there are any extractor fans in adjacent rooms, the test must be repeated with the fans running on maximum and interconnecting doors open.

IF SPILLAGE PERSISTS, DISCONNECT THE APPLIANCE AND SEEK EXPERT ADVICE.

1.7 Complete the Commissioning Checklist at the front of this manual covering:

Flue checks

Gas checks

Log layout - flame picture

1.8 Upon completion of the commissioning and testing of the installation and correct operation of the appliance, the installer must instruct the user how to operate the appliance.

1.9 Guide the user through the User Instructions paying particular attention to:

a) Regular servicing (Section 11 of the User Instructions).

b) Ventilation (Section 12 of the User Instructions) - point out the ventilation positions where applicable.

c) Hot surfaces (Section 14 of the User Instructions).

Commissioning

19

1. Servicing Requirements

IMPORTANT The glass panel on this appliance should be checked for any signs of damage on the front face of the glass panel (scratches, scores, cracks or other surface defects). If damage is observed, the glass panel must be replaced and the appliance must not be used until a replacement is installed. Under no circumstances should the appliance be used if any damage is observed. Please isolate the appliance until a replacement glass panel has been obtained and installed. Replacement glass panels can be purchased via the retailer from which the appliance was purchased or any other Dovre distributor.

This appliance must be serviced at least once a year by a competent person.

All tests must be carried out in accordance with the current GasSafe recommendations.

1.1 Before Testing:

Conduct a gas soundness test for the property ensuring there are no leaks before servicing.

Check the operation of the appliance before testing.

1.2 Special checks:

Clean the burner using a vacuum cleaner with a soft brush attachment. Ensure all debris is removed from the burner ports.

Clean away lint or fluff from the pilot. Clean away lint or fluff from under the burner. Check the spark gap on the pilot is correct, see Diagram 1. Ensure that the glass frame is secured correctly and that

all retaining screws are in place.

1.3 Correct any faults found during the initial test.

1.4 Re-commission the appliance in accordance with Commissioning Procedures.

1.5 Advise the customer of any remedial work undertaken.

13mm 7 mm1

Servicing Instructions Servicing/Fault Finding Charts

IG N

IT IO

N F

U N

C TI

O N

A L

C H

EC K

1

PI LO

T W

IL L

N O

T LI

G H

T

En su

re th

er e

is n

o de

br is

a ro

un d

th e

pi lo

t a ss

em bl

y,

(e .g

. s oo

t, et

c. ) w

hi ch

c ou

ld s

ho rt

th e

sp ar

k, c

le an

th e

ar ea

.

O pe

ra te

th e

va lv

e. Is

th er

e a

sp ar

k?

C on

su lt

U se

r In

st ru

ct io

ns a

nd re

try .

C he

ck a

lig nm

en t o

f p ilo

t bu

rn er

h ea

d, c

ha ng

e th

e ig

ni tio

n le

ad ,

Se e

se ct

io n

7 Re

pl ac

in g

Pa rts

C he

ck is

ol at

io n

ta p

an d

ga s

m et

er , r

et ry

.

C or

re ct

a nd

re

try .

Pu rg

e th

e ga

s pi

pe s

an d

re try

.

G O

T O

T H

E N

EX T

C

H A

R T

IG N

IT IO

N

FU N

C TI

O N

A L

C H

EC K

2 SY

ST EM

O K

Th er

e is

a b

lo ck

ag e

in th

e sy

st em

, c he

ck th

e in

le t t

es t p

oi nt

, th

e m

ag s

ea tin

g, v

al ve

a nd

p ilo

t f ilt

er .

Is th

e ga

s tu

rn ed

o n

to th

e ap

pl ia

nc e?

Is th

e ga

s pr

es su

re c

or re

ct ?

H as

th e

sy st

em g

ot

an y

ai r i

n it?

D oe

s th

e pi

lo t l

ig ht

?

Is th

e co

nt ro

l b ei

ng

op er

at ed

c or

re ct

ly ?

W ill

th e

pi lo

t l ig

ht

w ith

a m

at ch

?

N o

Ye s

N o

Ye s

N o

Ye s

Ye s

N o

N oYe

s

N o

N o Ye

s

Ye s

20

FL A

M E

FA IL

U R

E FU

N C

TI O

N A

L C

H EC

K 3

IG N

IT IO

N F

U N

C TI

O N

A L

C H

EC K

2

R em

ov e

th e

el ec

tro de

le ad

fro

m th

e pi

ez o.

O pe

ra te

th e

va lv

e. D

oe s

a sp

ar k

ju m

p fro

m

th e

pi ez

o to

th e

va lv

e bo

dy ?

R ep

la ce

th e

pi ez

o an

d ga

s va

lv e

an d

re try

.

Ye s

N o

PI LO

T W

IL L

N O

T ST

AY L

IT O

R F

IR E

G O

ES O

U T

IN U

SE

En su

re th

er e

is n

o de

br is

a ro

un d

th e

pi lo

t a ss

em bl

y, (e

.g . s

oo t e

tc .)

C he

ck fo

r f lu

ff in

th e

pi lo

t a er

at io

n ho

le .

Se e

th e

D ia

gr am

in th

e R

ep la

ci ng

P ar

ts s

ec tio

n.

Pr ob

le m

is w

ith th

e pi

pe w

or k

or

fit tin

gs w

hi ch

le ad

to

th e

ap pl

ia nc

e.

C or

re ct

an

d re

try .

Is th

er m

oc ou

pl e

co nn

ec tio

n go

od

in b

ac k

of v

al ve

?

R ep

la ce

th

er m

oc ou

pl e.

W ill

pi lo

t st

ay a

lig ht

?

C ha

ng e

m ag

un

it.

Is th

e pi

lo t f

la m

e of

th

e co

rre ct

le ng

th ?

Se

e Se

rv ic

in g

R eq

ui re

m en

ts

D ia

gr am

1 .

C ha

ng e

th e

p ilo

t u ni

t.

W ill

pi lo

t st

ay a

lig ht

? W

ith th

e pi

lo t

ru nn

in g

is th

e ga

s pr

es su

re a

s st

at ed

o n

th e

da ta

b ad

ge ?

W ith

th e

ap pl

ia nc

e ru

nn in

g on

fu ll

is th

e ga

s at

th

e pr

es su

re s

ta te

d

on th

e da

ta b

ad ge

?

R un

fo r n

o m

or e

th an

6 0

se co

nd s

tu

rn o

ff, ti

m e

in te

rv al

un

til m

ag u

ni t s

hu ts

w

ith a

c lic

k. Is

th is

gr

ea te

r t ha

n 7

se co

nd s?

R un

fo r a

m ax

im um

o f

60 s

ec on

ds , t

ur n

of f,

tim e

in te

rv al

u nt

il m

ag

un it

sh ut

s w

ith a

c lic

k.

Is th

is g

re at

er th

an 7

se

co nd

s?

Ti gh

te n

th e

co

nn ec

tio n

an d

re try

.

N o

N o

N o

N o

N o

N o

Ye s

SY ST

EM O

K

Ye s

Ye s

Ye s

Ye s

N o

Ye s

Ye s

N oLi gh

t t he

p ilo

t a nd

k ee

p th

e co

nt ro

l k no

b pu

sh ed

in

at le

as t 1

0 se

co nd

s be

fo re

re le

as in

g.

N O

S PA

R K

En su

re th

er e

is n

o de

br is

a ro

un d

th e

pi lo

t a ss

em bl

y, (e

.g . s

oo t e

tc .)

w hi

ch c

ou ld

s ho

rt th

e sp

ar k,

c le

an th

e ar

ea .

C on

su lt

th e

us er

s in

st ru

ct io

ns , r

et ry

.

O pe

ra te

th e

va lv

e to

li gh

t th

e pi

lo t,

do es

th e

va lv

e 'cl

ic k'?

O pe

ra te

th e

va lv

e to

li gh

t th

e pi

lo t,

do es

th e

va lv

e 'cl

ic k'?

H as

ig ni

tio n

le ad

be

co m

e de

ta ch

ed o

r i s

co nn

ec tio

n po

or ?

R em

ov e

th e

ig ni

tio n

le ad

fro

m e

le ct

ro de

w ith

in su

la te

d

pl ie

rs . H

ol d

th e

tip 4

m m

fr om

th e

pi

lo t p

ip ew

or k,

is th

er e

a sp

ar k

w

he n

th e

va lv

e c

lic ks

?

Is th

e el

ec tro

de w

ire

de ta

ch ed

fr om

th e

pi ez

o

in th

e va

lv e?

R ep

la ce

th e

co m

bi ne

d le

ad a

nd p

ie zo

, r et

ry .

C or

re ct

a nd

re try

.

C he

ck fo

r d ef

ec tiv

e or

da

m ag

ed c

on tro

l k no

b sp

in dl

e

or c

am o

pe ra

tio n.

C he

ck fo

r co

rre ct

lo ca

tio n

of p

ie zo

co

m po

ne nt

s. C

or re

ct a

nd re

try .

Is th

e co

nt ro

l s ys

te m

b ei

ng

op er

at ed

c or

re ct

ly ?

R es

et th

e pi

lo t b

ur ne

r.

Ye s

Ye s

Ye s

N o

N o

N o

Ye s

Ye s

Ye s

N o N

o

R ep

la ce

th e

el ec

tro de

. R

ep la

ce th

e el

ec tro

de

le ad

a nd

re try

.

Is th

e flu

e w

or ki

ng ?

R ec

tif y

flu e

N o

Ye s

Ye s

Fault Finding Charts

Servicing Instructions

21

Servicing Instructions - Replacing Parts 3. Window Frame Assembly

3.1 Remove the glass frame by undoing the fixing screws and lifting clear, see Diagram 3. Take care to support the glass window panel when removing the screws.

3

3.2 Place carefully to one side.

3.3 Lift out the log guard and carefully remove the ceramic fuel bed components.

3.4 Refit in reverse order.

3.5 Ensure that the rope seal on the back of the glass frame is intact and replace the screws working from the top down. Tighten the screws evenly DO NOT OVER TIGHTEN, see Diagram 3.

NEVER OPERATE THE APPLIANCE WHEN THE GLASS FRAME IS REMOVED OR BROKEN.

3.6 Replace ALL of the securing screws ensuring that a screw is present in all fixing slots.

UNDER NO CIRCUMSTANCES SHOULD THE APPLIANCE BE USED IF ANY OF THE GLASS FRAME RETAINING SCREWS ARE LOOSE OR MISSING.

1. General

1.1 All main components can be replaced without removing the appliance from its installation.

1.2 Ensure the appliance and surrounds are cool before servicing.

IT IS ESSENTIAL THAT THE GAS SUPPLY TO THE APPLIANCE IS TURNED OFF AT THE ISOLATION DEVICE BEFORE PROCEEDING FURTHER.

2. Removing the Door

IMPORTANT: THE OUTER PANELLING OF THE APPLIANCE IS MADE FROM CAST IRON. USE CAUTION WHEN INSTALLING, REMOVING AND STORING AS THE COMPONENTS ARE HEAVY AND SHOULD BE HANDLED CAREFULLY.

2.1 For rear flue exit lift the top of the appliance off and put to one side.

2.2 For top flue exit lift and support the top to give clearance, see Diagram 1.

1

2.3 Lift the front upwards until it is clear of the slots and pull away from the appliance, see Diagram 2.

2

22

Servicing Instructions - Replacing Parts 4. Baffle & Ceramic Liners

4.1 To access the burner tray and interior workings of the appliance it may be necessary to remove the baffle and the liners.

BAFFLE

4.2 The baffle must be removed before the liners can be taken out of the appliance.

To do this undo the two screws securing it to the roof of the firebox, see Diagram 4.

Screws

4

4.3 The baffle can now be removed through the front of the appliance.

CERAMIC LINERS

Once the baffle has been placed carefully to one side the liners can then been taken out in the following order.

4.4 To remove the Left Hand liner first tilt inwards towards the centre of the firebox before lifting up and pulling out through the front of the firebox, see Diagram 5.

5

4.5 To remove the Right Hand liner first tilt inwards towards the centre of the firebox before lifting up and pulling out through the front of the firebox, see Diagram 5.

The two side liners also support the raised rear liner. Taking out the side liners will allow the rear liner to drop

down so ensure it is supported and removed carefully, see Diagram 6.

6

4.6 The lower rear liner does not need to be removed from the bracket in order to access the burner tray for maintenance, but can be lifted off in order to clean or replace, see Diagram 7.

7

23

Servicing Instructions - Replacing Parts 4.7 With the liners and baffle removed the firebox is clear for

cleaning and maintenance, see Diagram 8.

8

4.8 To replace the liners liner and baffle reverse these procedures.

5. Main Burner

5.1 To replace the main burner:

Remove the baffle and enamel liners, see Section 4.

5.2 Remove the three securing screws from the edges of the burner, see Diagram 9.

9

Screws

5.3 Slide the burner fully to the right whilst lifting the Left Hand side clear of the bracket, see Diagram 10.

10

Slide to the right and lift the Left hand side

5.4 Slide the burner back to the left and out of its location. IMPORTANT: Take care when removing the burner not

to damage the ceramic pad with the pilot unit attached.

Refit in reverse order.

6. Pilot Unit

6.1 The pilot assembly consists of five components, which can be individually replaced:

6a) Pilot burner bracket 6b) Pilot injector 6c) Electrode 6d) Thermocouple 6e) Gasket

6.2 Turn the gas supply off at the isolation device, remove the door and place to one side, carefully remove the ceramic fuel bed components.

6a. Pilot Burner Bracket 6.3 Remove the two fixing screws from the pilot bracket, see

Diagram 11. Gently draw the assemble away from the firebox to give access to the nuts and ignition lead.

NOTE: TAKE CARE NOT TO DAMAGE THE GASKET.

11

6b. Pilot Injector

6.4 Undo the compression nut on the pilot feed pipe and withdraw the injector which will be hooked onto the olive. When replacing an injector always make sure it is hooked onto the olive before inserting it into the pilot burner, see Diagram 12.

12

24

Servicing Instructions - Replacing Parts 6c. Electrode

6.5 Disconnect the ignition lead and undo the retaining nut. The electrode can now be removed, note the orientation of the electrode terminal when reassembling, see Diagram 13.

13

6d. Thermocouple

6.6 Undo the retaining nut and withdraw the thermocouple. Undo the thermocouple from the back of the gas valve, see Diagram 14. Reassemble in reverse order. Do not overtighten.

14

6e. Gasket

6.7 Disconnect all the above components and withdraw the gasket. If it is damaged, replace with a new item. Always replace the gasket first when reassembling the pilot components.

7. Ignition Lead 7.1 Follow the Pilot Unit instruction to access the back of the

pilot assembly.

7.2 Disconnect the ignition lead from the electrode.

7.3 Remove the front cover from the control valve by removing the retaining screw, Diagram 15 and gently levering clear with flat bladed screwdriver, see Diagram 16.

NOTE: There is a small cylindrical metal spacer inside the cover, this must be kept and replaced on the fixing screw on re-assembly

15

16

7.4 Disconnect the other end of the ignition lead from the valve body noting the route of the ignition lead.

7.5 Replace with a new ignition lead following the same route as the old one.

Replace the valve cover and the pilot assembly.

7.6 Check operation of the new ignition lead.

8. Piezo

8.1 The piezo assembly used on this appliance is not serviceable and is unlikely to fail.

8.2 If a new piezo is required it will be necessary to change the valve, see Section 9.

25

Servicing Instructions - Replacing Parts 9. Gas Valve

9.1 To remove the valve turn off the gas supply at the isolation device.

9.2 Disconnect the 2 x 8mm and 1 x 4mm gas pipe fittings at the back of the gas valve, see Diagram 17 (A).

9.3 Disconnect the thermocouple, see Diagram 17 (B).

C

C

B A

D

A

17

9.4 Disconnect the ignition lead from the gas valve, see Diagram 17 (D)

9.5 Remove the cover, see Section 7.3.

9.6 Undo the two bolts securing the gas valve to the appliance and remove the valve, see Diagram 17 (C).

9.7 Replace in reverse order.

9.8 Check all joints for gas leaks and check operation of the thermocouple and ignition lead.

10. Magnetic Safety Valve 10.1 Turn the gas supply off at the isolation device.

10.2 Undo the thermocouple connection from the back of the gas valve, see Diagram 18 (A).

10.3 Pull the sensor leads clear and remove the interrupter block, see Diagram 18 (B).

10.4 Undo the magnetic valve-retaining nut from the back of the control valve, see Diagram 18 (C).

10.5 Gently tap out the magnetic valve and replace with a new unit.

10.6 Replace the retaining nut and tighten.

C

B A

18

10.7 Reassemble the interrupter block and leads and secure the thermocouple connection in the rear of the gas control. (Do not overtighten).

10.8 Turn the gas supply on and check the entire pipework and valve joints for any leaks

11. Main Injector

11.1 To remove the main injector turn off the gas supply at the isolation device.

11.2 Remove the main burner, see Section 5.

11.3 Undo the compression nuts from the feed pipe and the gas valve under the appliance.

11.4 Working from inside the firebox remove the lock nut from the injector, see Diagram 19.

19

11.5 Extract the injector with the feed pipe from beneath the appliance.

11.6 Holding the injector with a spanner:

11.7 Undo the feed pipe. Note the orientation of the Injector.

11.8 Re-assemble in reverse order.

11.9 Turn on the gas supply and check for leaks.

12. Flue Sure System

12.1 Open the door and remove the ceramics, placing them carefully to one side.

12.2 Undo the two screws in the back of the firebox and carefully withdraw the bracket, see Diagram 20 and 21.

20

26

21

12.3 Disconnect the two sensor wires.

12.4 Undo the two retaining screws.

12.5 Remove the sensor and the two plastic spacers, see Diagram 22.

22

Screws

Sensor

Spacers

12.6 Refit the new sensor ensuring the plastic spacers are located between the bracket and the sensor.

12.7 Refit the leads.

12.8 Feed the cable back through the hole as you replace the bracket.

When the bracket is located correctly it sits flush with the back panel without force. If not positioned correctly the bracket sits at an angle, see Diagram 23.

23

Servicing Instructions - Replacing Parts 13. Primary Aeration Plate

NOTE: Not all models have aeration plates. Please refer to the Technical Specification.

13.1 To replace the primary aeration plate turn off the gas supply at the isolation device.

13.2 Remove the burner, see Installation Instructions, Replacing Parts, Section 5.

13.3 Detach the aeration plate from the venturi, see Diagram 24.

24

13.4 Reassemble in reverse order. NOTE: Even if no aeration plate is required, the small

screw must be replaced.

14. Changing Between Gas Types

In order to change between gas types, it will be necessary to change the following items:

Pilot Injector Control Valve Injector Aeration Plate (if required) Data Badge

A kit of parts is available for this, always quote the Model number and Serial number when ordering any spare parts.

NOTE: THE CONTROL VALVE IS FACTORY PRESET FOR THE CORRECT GAS TYPE AND MODEL, A NEW UNIT WILL NEED TO BE ORDERED WHEN CHANGING BETWEEN GAS TYPES.

15. Control Upgrade

See Installation Instructions, Section 2.

27

16. Spare Parts List - Control Assembly

No. Component Part Code Quantity

1 Control Valve GC0088K 1

2 Control Valve Cover GC0087 1

3 Mag. Unit GC0166 1

4 Micro Switch & Screw EL0241 1

5 Standard Headset EL0239 1

6 Thermostatic Handset EL0240 1

7 Standard Receiver EL0235 1

8 Thermostatic Receiver EL0236 1

9 Thermostatic Receiver Cable EL0238 1

10 Standard Receiver Cable EL0237 1

11 Geared Motor EL0234 1

12 Ignition Lead GC0090 1

Servicing Instructions - Replacing Parts

Due to continual technical improvements please check online or with your Dovre retailer for the most up to date parts lists.

Only use Genuine Dovre spares when servicing your appliance.

28

Servicing Instructions - Replacing Parts 16. Spare Parts List - Dovre 280

Due to continual technical improvements please check online or with your Dovre retailer for the most up to date parts lists.

Only use Genuine Dovre spares when servicing your appliance.

29

No. Component Part Code

Natural Gas LPG Quantity

1 Blanking Plate - Matt Black DV-03.15348.002 1

1 Blanking Plate - Ivory Enamel DV-03.15348.082 1

1 Blanking Plate - Black Enamel DV-03.15348.084 1

1 Blanking Plate - Majolica Brown Enamel DV-03.15348.086 1

1 Blanking Plate - Ivory White Enamel DV-03.15348.087 1

2 Top Plate Casting - Matt Black DV-03.69200.002 1

2 Top Plate Casting - Ivory Enamel DV-03.69200.082 1

2 Top Plate Casting - Black Enamel DV-03.69200.084 1

2 Top Plate Casting - Majolica Brown Enamel DV-03.69200.086 1

2 Top Plate Casting - Ivory White Enamel DV-03.69200.087 1

3 Top Heat Shield GZ10622 1

4 Spigot MEC0033 1

5 Instruction Manual PR1812 1

6 Pilot Body PI0051 1

7 Pilot Injector PI0026 PI0015 1

8 Hook Nut PI0014 1

9 Electrode PI0053 1

10 RH Firebox Location Plate GZ6222 1

11 LH & RH Side Casting - Matt Black DV-03.79189.005 1

11 LH & RH Side Casting - Ivory Enamel DV-03.79189.082 1

11 LH & RH Side Casting - Black Enamel DV-03.79189.084 1

11 LH & RH Side Casting - Majolica Brown Enamel DV-03.79189.086 1

11 LH & RH Side Casting - Ivory White Enamel DV-03.79189.087 1

12 Control Assembly B0216 1

Servicing Instructions - Replacing Parts 16. Spare Parts List - Dovre 280

No. Component Part Code

Natural Gas LPG Quantity

13 Skirt GZ7045 1

14 Elbow Injector IN0001 Size 260

IN0065 Size 102 1

15 Thermocouple PI0011 1

16 Hook Olive PI0013 1

17 Pilot Gasket PI0052 1

18 RH Ceramic Panel CE1014 1

19 Rear Log Retainer GZ9553 1

20 Base Ceramic Panel CE0997 CE1024 1

21 Burner Assembly GZ9712 GZ9712 1

22 Aeration Plate GZ3270 GZ2025 1

23 Door Handle GZ6977 1

24 M6 x 8mm LG Pozi Pan Head Screw FA0063 2

25 Front Casting - Matt Black DV-03.24435.005 1

25 Front Casting - Ivory Enamel DV-03.24435.082 1

25 Front Casting - Black Enamel DV-03.24435.084 1

25 Front Casting - Majolica Brown Enamel DV-03.24435.086 1

25 Front Casting - Ivory White Enamel DV-03.24435.087 1

26 Glass Frame Assembly GZ6025 1

27 Log Retainer CA0744 1

28 LH Ceramic Panel CE1013 1

29 Log Set CE0960 1

30 Back Ceramic Panel CE1015 1

31 Top Ceramic Panel CE1016 1

32 Embaglow GZ8471 1

33 LH Firebox Location Plate GZ6221 1

34 Interrupter Block GC0026 1

35 Flue Sensor Leads EL0064 2

36 Flue Sensor EL0001 1

Due to continual technical improvements please check online or with your Dovre retailer for the most up to date parts lists.

Only use Genuine Dovre spares when servicing your appliance.

30

1ST SERVICE

Date of Service .........................................................................

Next Service Due ......................................................................

Signed .......................................................................................

Retailer's Stamp/GasSafe Registration Number

3RD SERVICE

Date of Service .........................................................................

Next Service Due ......................................................................

Signed .......................................................................................

Retailer's Stamp/GasSafe Registration Number

5TH SERVICE

Date of Service .........................................................................

Next Service Due ......................................................................

Signed .......................................................................................

Retailer's Stamp/GasSafe Registration Number

7TH SERVICE

Date of Service .........................................................................

Next Service Due ......................................................................

Signed .......................................................................................

Retailer's Stamp/GasSafe Registration Number

9TH SERVICE

Date of Service .........................................................................

Next Service Due ......................................................................

Signed .......................................................................................

Retailer's Stamp/GasSafe Registration Number

2ND SERVICE

Date of Service .......................................................................

Next Service Due ....................................................................

Signed .....................................................................................

Retailer's Stamp/GasSafe Registration Number

4TH SERVICE

Date of Service .......................................................................

Next Service Due ....................................................................

Signed .....................................................................................

Retailer's Stamp/GasSafe Registration Number

6TH SERVICE

Date of Service .......................................................................

Next Service Due ....................................................................

Signed .....................................................................................

Retailer's Stamp/GasSafe Registration Number

8TH SERVICE

Date of Service .......................................................................

Next Due .................................................................................

Signed .....................................................................................

Retailer's Stamp/GasSafe Registration Number

10TH SERVICE

Date of Service .......................................................................

Next Service Due ....................................................................

Signed .....................................................................................

Retailer's Stamp/GasSafe Registration Number

Service Records

31

Model

D ov

re 2

80

N at

G as

D ov

re 2

80

LP G

Fu el Space Heating Emissions (NOx) - mg / kWh input (GCV) 130 130

H ea

t O

ut pu

t Nominal Heat Output - Pnom 3.1kW 3.0kW

Minimum Heat Output (indicative) -Pmin 1.5kW 1.5kW

A ux

ili ar

y El

ec tr

ic ity

C

on su

m pt

io n At Nominal Heat Output - elmax N/A N/A

At Minimum Heat Output - elmin N/A N/A

In Standby Mode - elsb N/A N/A

U se

fu l

Ef fic

ie nc

y Useful Efficiency at nominal heat output - th,nom 75.0% 75.0%

Useful Efficiency at minimum heat output (indicative) - th,min

65.0% 65.0%

Pe rm

an en

t Pi

lo t F

la m

e Po

w er

re

qu ire

m en

t

Permanent Pilot Flame Power requirement (if applicable) - Ppilot

0.200kW 0.200kW

Type of heat output/room temperature control - Manual Control Electronic room temperature control + day timer Yes Yes

Other control options (multiple selections possible) Room temperature control, with presence detection No No Room temperature control, with open window detection No No With distance control option No No With adaptive start control No No With working time limitation No No With black bulb sensor No No

Energy Efficiency Index 67.7% 67.7%

Manualsnet FAQs

If you want to find out how the 280 Dovre works, you can view and download the Dovre 280 DV541-010 Stove Installation Manual on the Manualsnet website.

Yes, we have the Installation Manual for Dovre 280 as well as other Dovre manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Installation Manual should include all the details that are needed to use a Dovre 280. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Dovre 280 DV541-010 Stove Installation Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Dovre 280 DV541-010 Stove Installation Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Dovre 280 DV541-010 Stove Installation Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Dovre 280 DV541-010 Stove Installation Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Dovre 280 DV541-010 Stove Installation Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.