Dell EMC PowerFlex appliance R640 Owner's Guide

October 2020 Rev. 05

Notes, cautions, and warnings

NOTE: A NOTE indicates important information that helps you make better use of your product.

CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid

the problem.

WARNING: A WARNING indicates a potential for property damage, personal injury, or death.

2019 - 2020 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.

Chapter 1: PowerFlex appliance R640 system overview................................................................. 5 Front view of the R640 system....................................................................................................................................... 5

Control panels.................................................................................................................................................................7 LCD panel........................................................................................................................................................................ 8

Back view of the R640 system.......................................................................................................................................10 Locating the Service Tag of your system..................................................................................................................... 11 System information tag.................................................................................................................................................... 12

Front system information........................................................................................................................................... 12 Front system information label................................................................................................................................. 13

Chapter 2: Technical specifications............................................................................................. 15 System dimensions............................................................................................................................................................ 15 Chassis weight....................................................................................................................................................................16 Processor specifications.................................................................................................................................................. 16 Cooling fan specifications................................................................................................................................................ 17 PSU specifications............................................................................................................................................................. 17

Hot spare feature......................................................................................................................................................... 17 System battery specifications.........................................................................................................................................18 Expansion card riser specifications................................................................................................................................18

Expansion card installation guidelines..................................................................................................................... 18 System memory..................................................................................................................................................................18

Memory specifications............................................................................................................................................... 20 General memory module installation guidelines....................................................................................................20 NVDIMM-N memory module installation guidelines ............................................................................................21 Optimizer mode............................................................................................................................................................ 21

Storage controller specifications....................................................................................................................................21 Drive specifications...........................................................................................................................................................22 Ports and connector specifications.............................................................................................................................. 22

USB ports...................................................................................................................................................................... 22 NIC ports....................................................................................................................................................................... 22 VGA ports......................................................................................................................................................................22 Serial port...................................................................................................................................................................... 22

Video specifications.......................................................................................................................................................... 22 Environmental specifications..........................................................................................................................................23

Standard operating temperature............................................................................................................................. 24 Expanded operating temperature............................................................................................................................24 Particulate and gaseous contamination specifications.......................................................................................25

Chapter 3: System diagnostics and indicator codes.....................................................................26 Indicator codes ................................................................................................................................................................. 26

Status LED indicators.................................................................................................................................................26 System health and system ID indicator codes......................................................................................................27 iDRAC Quick Sync 2 indicator codes...................................................................................................................... 27 iDRAC Direct LED indicator codes.......................................................................................................................... 28

Contents

Contents 3

NIC indicator codes.....................................................................................................................................................28 Power supply unit indicator codes.......................................................................................................................... 29 Drive indicator codes..................................................................................................................................................30

Using system diagnostics.................................................................................................................................................31 Dell Embedded System Diagnostics.........................................................................................................................31

Chapter 4: Reference material.....................................................................................................33 Trusted Platform Module................................................................................................................................................ 33

Upgrading the Trusted Platform Module...............................................................................................................33 Initialize the TPM for BitLocker users.................................................................................................................... 33 Initialize the TPM 1.2 for TXT users........................................................................................................................33

Chapter 5: Getting help...............................................................................................................35 Contacting Dell EMC........................................................................................................................................................ 35 Secure Remote Services................................................................................................................................................. 35 Recycling or End-of-Life service information............................................................................................................ 35

4 Contents

PowerFlex appliance R640 system overview The PowerFlex appliance R640 system is a 1U rack server that supports a maximum of:

Two Intel Xeon Scalable Processors 24 DIMM slots 8 or 10 x 2.5-inch drives or 0 drives for diskless configuration Two AC redundant power supply units SAS, SATA, SAS SED, and NVMe

NOTE: All instances of SAS, SATA, SAS SED, and NVMe drives are referred to as drives in this document, unless specified

otherwise.

Front view of the R640 system The front view displays the features available on the front of the R640 system. There are two available versions for the R640 an 8-drive or 10-drive system.

Front view of 8-drive system

Figure 1. Front view of the 8-drive system

Table 1. Features available on the front of the 8-drive system

Item Ports, panels, and slots

Icon Description

1 Left control panel N/A Contains the system health and system ID, status LED, and the iDRAC Quick Sync 2 (wireless) indicator.

NOTE: The iDRAC Quick Sync 2 indicator is available only on certain configurations.

Status LED: Enables you to identify any failed hardware components. There are up to five status LEDs and an overall system health LED (Chassis health and system ID) bar. For more information, see Status LED indicators on page 26.

Quick Sync 2 (wireless): Indicates a Quick Sync enabled system. The Quick Sync feature is optional. This feature allows management of the system by using mobile devices. This feature aggregates hardware or firmware inventory and various system level diagnostic and error information that can be used in troubleshooting the system. For more information, see the Integrated Dell Remote Access Controller Users Guide at dell.com/support/.

2 Drive slots N/A Enable you to install drives that are supported on your system. For more information, see Technical specifications.

1

PowerFlex appliance R640 system overview 5

Table 1. Features available on the front of the 8-drive system (continued)

Item Ports, panels, and slots

Icon Description

3 USB port (Optional) The USB port is USB 3.0 compliant.

4 VGA port Enables you to connect a display device to the system. For more information, see Technical specifications.

5 Right control panel N/A Contains the power button, USB port, iDRAC Direct micro port, and the iDRAC Direct status LED.

6 Drive slots N/A Enable you to install drives that are supported on your system. For more information, see Technical specifications.

Front view of 10-drive system

Figure 2. Front view of 10-drive system

Table 2. Features available on the front of the 10-drive system

Item Ports, panels, and slots

Icon Description

1 Left control panel N/A Contains the system health and system ID, status LED, and the iDRAC Quick Sync 2 (wireless) indicator.

NOTE: The iDRAC Quick Sync 2 indicator is available only on certain configurations.

Status LED: Enables you to identify any failed hardware components. There are up to five status LEDs and an overall system health LED (Chassis health and system ID) bar. For more information, see Status LED indicators on page 26.

Quick Sync 2 (wireless): Indicates a Quick Sync enabled system. The Quick Sync feature is optional. This feature allows management of the system by using mobile devices. This feature aggregates hardware or firmware inventory and various system level diagnostic and error information that can be used in troubleshooting the system. For more information, see the Integrated Dell Remote Access Controller Users Guide at dell.com/support/.

2 Drive slots N/A Enable you to install drives that are supported on your system. For more information, see Technical specifications.

3 VGA port Enables you to connect a display device to the system. For more information, see Technical specifications.

4 Right control panel N/A Contains the power button, USB port, iDRAC Direct micro port, and the iDRAC Direct status LED.

5 Service tag N/A The Service Tag is a slide-out label panel that contains system information such as Service Tag, NIC, MAC address, and so on. If you have opted for the secure default access to iDRAC,

6 PowerFlex appliance R640 system overview

Table 2. Features available on the front of the 10-drive system (continued)

Item Ports, panels, and slots

Icon Description

the Information tag also contains the iDRAC secure default password.

Control panels

This section describes the system's control panels.

Left control panel view

The left control panel with optional iDRAC Quick Sync 2.0 indicator is explained as follows:

Figure 3. Left control panel

Table 3. Left control panel options

Item Indicator or button Icon Description

1 Status LED indicators N/A Indicate the status of the system. For more information, see Status LED indicators.

2 System health and system ID indicator

Indicates the system health. For more information, see System health and system ID indicator codes.

3 iDRAC Quick Sync 2 wireless indicator (optional)

Indicates if the iDRAC Quick Sync 2 wireless option is activated. The Quick Sync 2 feature allows management of the system using mobile devices. This feature aggregates hardware/ firmware inventory and various system level diagnostic/error information that can be used in troubleshooting the system. You can access system inventory, Dell EMC Lifecycle Controller logs or system logs, system health status, and also configure iDRAC, BIOS, and networking parameters. You can also launch the virtual Keyboard, Video, and Mouse (KVM) viewer and virtual Kernel based Virtual Machine (KVM), on a supported mobile device. For more information about the feature, see the Integrated Dell Remote Access Controller User's Guide at https://www.dell.com/idracmanuals.

NOTE: iDRAC Quick Sync 2 wireless indicator is available only on certain configurations.

NOTE: For more information about the indicator codes, see System diagnostics and indicator codes.

PowerFlex appliance R640 system overview 7

Right control panel view

The right control panel is explained as follows:

Figure 4. Right control panel

Table 4. Right control panel

Item Indicator or button Icon Description

1 Power button Indicates whether the system is turned on or off. Press the power to manually turn the system on or off.

2 USB port The USB ports are 4-pin, 2.0-compliant. This port enables you to connect USB devices to the system.

3 iDRAC Direct LED N/A The iDRAC Direct LED indicator lights up to indicate that the iDRAC Direct port is actively connected to a device. For more information, see iDRAC Quick Sync 2 indicator codes on page 27.

4 iDRAC Direct port (Micro- AB USB)

The iDRAC Direct (Micro-AB USB) port enables you to access the iDRAC Direct (Micro-AB) features. For more information about the feature, see the Integrated Dell Remote Access Controller User's Guide at https://www.dell.com/idracmanuals.

NOTE: For more information on the ports, see Technical specifications.

LCD panel

The LCD panel provides system information, status, and error messages to indicate whether the system is functioning correctly or requires attention. The LCD panel can also be used to configure or view the systems iDRAC IP address.

The LCD panel is available only on the optional front bezel. The optional front bezel is hot pluggable.

The statuses and conditions of the LCD panel are outlined here:

The LCD backlight is white during normal operating conditions. When the system needs attention, the LCD backlight turns amber, and displays an error code followed by descriptive text.

NOTE: If the system is connected to a power source and an error is detected, the LCD turns amber regardless of

whether the system is turned on or off.

When the system turns off and there are no errors, LCD enters the standby mode after five minutes of inactivity. Press any button on the LCD to turn it on.

If the LCD panel stops responding, remove the bezel and reinstall it.

If the problem persists, see "Getting help" at the end of this publication.

The LCD backlight remains off if LCD messaging is turned off using the iDRAC utility, the LCD panel, or other tools.

8 PowerFlex appliance R640 system overview

Figure 5. LCD panel

Table 5. LCD panel features

Item Button or display

Description

1 Left Moves the cursor back in one-step increments.

2 Select Selects the menu item that is highlighted by the cursor.

3 Right Moves the cursor forward in one-step increments.

During message scrolling:

Press and hold the right button to increase scrolling speed. Release the button to stop.

NOTE: The display stops scrolling when the button is released. After 45 seconds of inactivity, the display starts scrolling.

4 LCD display Displays system information, status, and error messages or iDRAC IP address.

Viewing Home screen

The Home screen displays user-configurable information about the system. This screen is displayed during normal system operation when there are no status messages or errors. When the system turns off and there are no errors, LCD enters the standby mode after five minutes of inactivity. Press any button on the LCD to turn it on.

Steps

1. To view the Home screen, press one of the three navigation buttons (Select, Left, or Right).

2. To navigate to the Home screen from another menu, complete the following steps:

a. Press and hold the navigation button till the up arrow is displayed.

b. Navigate to the Home icon using the up arrow . c. Select the Home icon. d. On the Home screen, press the Select button to enter the main menu.

Setup menu

The Setup menu contains the following options:

NOTE: When you select an option in the Setup menu, you must confirm the option before proceeding to the next action.

iDRAC Select DHCP or Static IP to configure the network mode. If Static IP is selected, the available fields are IP, Subnet (Sub), and Gateway (Gtw). Select Setup DNS to enable DNS and to view domain addresses. Two separate DNS entries are available.

Set error Select SEL to view LCD error messages in a format that matches the IPMI description in the SEL. This enables you to match an LCD message with an SEL entry.

Select Simple to view LCD error messages in a simplified user-friendly description. For information about the event and error messages generated by the system firmware and agents that monitor system components, go to qrl.dell.com > Look Up > Error Code, type the error code, and then click Look it up.

PowerFlex appliance R640 system overview 9

Set home Select the default information to be displayed on the Home screen. See View menu section for the options and option items that can be set as the default on the Home screen.

View menu

The View menu contains the following options:

NOTE: When you select an option in the View menu, you must confirm the option before proceeding to the next action.

iDRAC IP Displays the IPv4 or IPv6 addresses for iDRAC9. Addresses include DNS (Primary and Secondary), Gateway, IP, and Subnet (IPv6 does not have Subnet).

MAC Displays the MAC addresses for iDRAC, iSCSI, or Network devices.

Name Displays the name of the Host, Model, or User String for the system.

Number Displays the Asset tag or the Service tag for the system.

Power Displays the power output of the system in BTU/hr or Watts. The display format can be configured in the Set home submenu of the Setup menu.

Temperature Displays the temperature of the system in Celsius or Fahrenheit. The display format can be configured in the Set home submenu of the Setup menu.

Back view of the R640 system The back view displays the features available on the back of the R640 system.

Figure 6. Back view of system with 3 PCIe expansion slots

Table 6. 2 X 2.5-inch drive system with 3 PCIe expansion slot

Item Ports, panels, or slots Icon Description

1 PCIe expansion card slot(3)

N/A The expansion slot(s) enable you to connect PCI Express expansion cards. For more information on the expansion cards that are supported on your system, see Expansion card guidelines.

2 Power supply unit (2) N/A For more information about the PSU configurations, see Technical specifications.

3 NIC port (4) The NIC ports that are integrated on the network daughter card (NDC) provide network connectivity. For more information about the supported configurations, see Technical specifications.

4 USB 3.0 port (2) The USB ports are 9-pin and 3.0-compliant. These ports enable you to connect USB devices to the system.

5 VGA port Enables you to connect a display device to the system. For more information, see Technical specifications.

6 Serial port Enables you to connect a serial device to the system. For more information, see Technical specifications.

10 PowerFlex appliance R640 system overview

Table 6. 2 X 2.5-inch drive system with 3 PCIe expansion slot (continued)

Item Ports, panels, or slots Icon Description

7 iDRAC9 dedicated network port

Use the iDRAC9 dedicated network port to securely access the embedded iDRAC on a separate management network. For more information about the feature, see the Integrated Dell Remote Access Controller User's Guide at https:// www.dell.com/idracmanuals.

8 System status indicator cable port

N/A Enables you to connect the status indicator cable and view system status when the CMA is installed.

9 System identification button

The System Identification (ID) button is available on the front and back of the system. Press the system ID button to identify a system in a rack. You can also use the system ID button to reset iDRAC and access BIOS using the step through mode.

Locating the Service Tag of your system You can identify your system using the unique Express Service Code and Service Tag. Pull out the information tag in the front of the system to view the Express Service Code and Service Tag. Alternatively, the information may be on a sticker on the chassis of the system.

The mini Enterprise Service Tag (EST) is found on the back of the system. This information is used by Dell EMC to route support calls to the appropriate personnel.

Figure 7. Service Tag

1. Information tag (top view) 2. Information tag (bottom view) 3. OpenManage Mobile (OMM) label (optional) 4. iDRAC MAC address and iDRAC secure password label

NOTE: If you have opted for secure default access to iDRAC, the iDRAC secure default password is available on the

back of the system Information tag. This section of label will be blank, if you have not opted for secure default access to

iDRAC, then the default user name and password are root and Scaleio123, respectively.

5. Service Tag

PowerFlex appliance R640 system overview 11

System information tag The Information tag is a slide-out label panel that contains system information such as Service Tag, NIC, MAC address, and so on. If you have opted for the secure default access to iDRAC, the Information tag also contains the iDRAC secure default password.

Front system information

Front system information explains LED behavior and displays drive configuration and layout

Figure 8. LED behavior

Figure 9. Configuration and layout and express Service Tag

NOTE: PowerFlex appliance only supports the 2.5 x 8 and 2.5 x 10 configurations.

12 PowerFlex appliance R640 system overview

Front system information label

The information tag displays information to assist service technicians, including system touchpoints, electrical and mechanical overviews, and rear view configurations. It also displays jumper settings and memory information.

Figure 10. Service information, electrical overview, network daughter card and miniPERC installation

PowerFlex appliance R640 system overview 13

Figure 11. Memory information, jumper setting and NVDIMM battery removal

14 PowerFlex appliance R640 system overview

Technical specifications The technical and environmental specifications of your system are outlined in this section.

System dimensions This topic provides details of the R640 system's dimensions:

Figure 12. System dimensions

Table 7. R640 system dimensions

System Xa Xb Y Za (with bezel)

Za (without bezel)

Zb* Zc

10 x 2.5-inches 482.0 mm

(18.97-inches)

434.0 mm

(17.08-inches)

42.8 mm

(1.68- inches)

35.84 mm

(1.41-inches)

22.0 mm

(0.87- inches)

733.82 mm

(29.61-inches)

772.67 mm

(30.42- inches)

2

Technical specifications 15

Chassis weight The following table shows the maximum weight of the R640 system chassis:

Table 8. Chassis weight

System Maximum weight (with all drives)

R640 21.9 kg

(48.28 lbs)

Processor specifications The R640 system supports two Intel Xeon Scalable Processors, up to 28 cores per processor.

16 Technical specifications

Cooling fan specifications The cooling fans are integrated into the system to dissipate the heat generated by the functioning of the system. These fans provide cooling for the processors, expansion cards, and memory modules.

Your system supports up to eight standard or high-performance cooling fans.

NOTE:

High-performance fans can be identified by a blue label on top of the cooling fan.

Mixing of standard and high-performance cooling fans is not supported.

Each fan is listed in the systems management software, referenced by the respective fan number. If there is a problem

with a particular fan, you can easily identify and replace the proper fan by noting the fan number on the system.

PSU specifications The R640 system supports up to two AC power supply units (PSUs).

Table 9. PSU specifications

PSU Class Heat dissipation (maximum)

Frequency Voltage

750 W AC Platinum 2891 BTU/hr 50/60 Hz 100240 V AC, autoranging

750 W AC Titanium 2843 BTU/hr 50/60 Hz 200240 V AC, autoranging

1100 W AC Platinum 4100 BTU/hr 50/60 Hz 100240 V AC, autoranging

1600 W AC 6000 BTU/hr 50/60 Hz 100240 V AC, autoranging

NOTE: If a system with 1100 W AC or HVDC PSU operates from 100 to 120V, the power rating per PSU is derated to 1050

W.

NOTE: If a system with 1600 W PSUs operates from 100 to 120 V, then the power rating per PSU is derated to 800 W.

NOTE: Heat dissipation is calculated using the PSU wattage rating.

NOTE: This system is also designed to connect to the IT power systems with a phase to phase voltage not exceeding 230

V.

NOTE: PSUs rated for 1600 W and higher require high-line voltage (200-240 V) to supply their rated capacity.

Hot spare feature

Your system supports the hot spare feature that significantly reduces the power overhead associated with power supply unit (PSU) redundancy.

When the hot spare feature is enabled, one of the redundant PSUs is switched to the sleep state. The active PSU supports 100 percent of the system load, thus operating at higher efficiency. The PSU in the sleep state monitors output voltage of the active PSU. If the output voltage of the active PSU drops, the PSU in the sleep state returns to an active output state.

If having both PSUs active is more efficient than having one PSU in the sleep state, the active PSU can also activate the sleeping PSU.

The default PSU settings are as follows:

If the load on the active PSU is more than 50 percent of PSU rated power wattage, then the redundant PSU is switched to the active state.

If the load on the active PSU falls below 20 percent of PSU rated power wattage, then the redundant PSU is switched to the sleep state.

You can configure the hot spare feature by using the iDRAC settings. For more information, see the iDRAC Users Guide available at .

Technical specifications 17

System battery specifications The R640 system supports CR 2032 3.0-V lithium coin cell system batteries.

Expansion card riser specifications The R640 system supports PCI express (PCIe) generation 3 expansion cards that are installed on the system using expansion card risers. This system supports 1A and 2A expansion card risers.

Expansion card installation guidelines

Depending on your system configuration, the following PCI Express (PCIe) generation 3 expansion cards are supported:

Table 10. Expansion card riser configurations

Expansion card riser PCIe slots on the riser

Processor connection

Height Length Slot width

Riser 1A Slot 1 Processor 1 Low Profile Half Length x16

Slot 2 Processor 1 Low Profile Half Length x16

Riser 2A Slot 3 Processor 2 Low Profile Half Length x16

NOTE: The expansion card slots are not hot-swappable.

System memory The system supports DDR4 Registered DIMMs (RDIMMs) and Non-Volatile DIMMs (NVDIMM-Ns: for storage and HCI nodes). System memory holds the instructions that are executed by the processor.

Your system contains 24 memory sockets split into two sets of 12 sockets, one set per processor. Each 12-socket set is organized into six channels. Six memory channels are allocated to each processor. In each channel, the release tabs of the first socket are marked white, and the second socket black.

18 Technical specifications

Figure 13. Memory socket locations

Memory channels are organized as follows:

Table 11. Memory channels

Processor Channel 0 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5

Processor 1 Slots A1 and A7 Slots A2 and A8 Slots A3 and A9 Slots A4 and A10

Slots A5 and A11 Slots A6 and A12

Processor 2 Slots B1 and B7 Slots B2 and B8 Slots B3 and B9 Slots B4 and B10

Slots B5 and B11 Slots B6 and B12

Technical specifications 19

Memory specifications

The following table shows the memory specifications for the R640 system:

Table 12. Memory specifications

DIMM type DIMM rank DIMM capacity Dual processors

Minimum RAM Maximum RAM

RDIMM Dual rank 16 GB 192 GB

12 slots must be populated.

384 GB

RDIMM Dual rank 32 GB 64 GB 768 GB

RDIMM Dual rank 64 GB 128 GB 1536 GB

NVDIMM-N Single rank 16 GB RDIMM: 192 GB RDIMM: 384 GB

NVDIMM-N: 32 GB NVDIMM-N: 96 GB

NOTE: 8 GB RDIMMs and NVDIMM-Ns must not be mixed.

NOTE: A minimum of two CPUs are required for any configurations that support NVDIMM-N.

General memory module installation guidelines

To ensure optimal performance of your system, observe the following general guidelines when configuring your system memory: If your system's memory configurations fail to observe these guidelines, your system might not boot, stop responding during memory configuration, or operate with reduced memory.

The memory bus operating frequency can be 2933 MT/s or 2666 MT/s, 2400 MT/s and 2100 MT/s depending on the following factors: Maximum supported DIMM speed of the processors Maximum supported speed of the DIMMs

NOTE: MT/s indicates DIMM speed in MegaTransfers per second.

The following are the recommended guidelines for installing memory modules:

All DIMMs must be DDR4. RDIMMs and LRDIMMs must not be mixed. NVDIMMs and LRDIMMs must not be mixed. NVDIMMs and RDIMMs can be mixed. x4 and x8 DRAM based memory modules can be mixed. Up to two RDIMMs can be populated per channel regardless of rank count. A maximum of two different ranked DIMMs can be populated in a channel regardless of rank count. Populate memory module sockets only if a processor is installed.

For dual-processor systems, sockets A1 to A12 and sockets B1 to B12 are available.

NOTE: PowerFlex appliance only supports dual socket memory.

Populate all the sockets with white release tabs first, followed by the black release tabs. When mixing memory modules with different capacities, populate the sockets with memory modules with the highest

capacity first. Memory modules of different capacities can be mixed provided other memory population rules are followed.

For example, 8 GB and 16 GB memory modules can be mixed.

In a dual-processor configuration, the memory configuration for each processor must be identical.

For example, if you populate socket A1 for processor 1, then populate socket B1 for processor 2, and so on.

Mixing of more than two memory module capacities in a system is not supported. Unbalanced memory configurations result in a performance loss so always populate memory channels identically with

identical DIMMs for best performance.

20 Technical specifications

Populate six identical memory modules per processor (one DIMM per channel) at a time to maximize performance. To ensure proper system cooling, memory module blanks must be installed in memory sockets that are not occupied. DIMM population update for Performance Optimized mode with quantity of 4 and 8 DIMMs per processor. When the DIMM quantity is 4 per processor, the population is slot 1, 2, 4, 5.

NVDIMM-N memory module installation guidelines

The following are the recommended guidelines for installing NVDIMM-N memory modules:

Each system supports memory configurations with 2, 4, or 6 NVDIMM-Ns. Supported configurations have dual processors and a minimum of 12x RDIMMs. Maximum of 6 NVDIMM-Ns can be installed in a system. DDR4 NVDIMM-Ns must be populated only on the black release tabs on processor 1 and 2.

Optimizer mode

This mode supports Single Device Data Correction (SDDC) only for memory modules that use x4 device width. It does not impose any specific slot population requirements.

Dual processor: Populate the slots in round robin sequence starting with processor 1.

NOTE: Processor 1 and processor 2 population should match.

Table 13. Memory population rules

Processor Configuration Memory population Memory population information

Dual processor (Start with processor1. Processor1 and processor 2 population should match.)

Optimized (Independent channel) population order

A{1}, B{1},

A{2}, B{2},

A{3}, B{3},

A{4}, B{4},

A{5}, B{5},

A{6}, B{6}

Odd number of DIMM population per processor is allowed.

NOTE: Odd number of DIMMs will result in unbalanced memory configurations, which in turn will result in performance loss. Dell EMC recommends that you populate all memory channels identically with identical DIMMs for best performance.

Optimizer population order is not traditional for 8 and 16 DIMMs installations for dual processor.

For 8 DIMMs: A1, A2, A4, A5, B1, B2, B4, B5

For 16 DIMMs:

A1, A2, A4, A5, A7, A8, A10, A11

B1, B2, B4, B5, B7, B8, B10, B11

Storage controller specifications The R640 system supports the following internal storage controller cards:

Internal storage controller cards: HBA330 (non-RAID)

Boot Optimized Storage Subsystem: HWRAID 2 x M.2 SSDs, 240 GB. The card supports up to two 6 Gbps M.2 SATA drives. The BOSS adapter card has a x8 connector using PCIe gen 2.0 x2

lanes, available only in the low-profile and half-height form factor.

Technical specifications 21

Drive specifications The R640 system supports up to ten 2.5-inch, hot swappable SAS, SATA, and SAS SED drives. The R640 also supports NVME SSD drives, which are not hot swappable. PowerFlex appliance also supports HDD drives.

Ports and connector specifications The R640 system supports the following ports and connectors:

USB ports

The following table provides information about the USB specifications for the R640 system:

Table 14. USB specifications

System Front panel Back panel Internal

Ten drive systems One 4-pins, USB 2.0-compliant port Two 9-pin, USB 3.0-compliant ports

One 9-pin, USB 3.0-compliant ports

One 5-pin micro USB 2.0 management port

N/A N/A

NIC ports

The R640 system supports four network interface controller (NIC) ports on the back panel, which are available in the following configurations:

Intel X710 DP 10 Gb DA/SFP+, + I350 DP 1 Gb Ethernet, Network Daughter Card X55 Quad port rNDC and X710 Quad port NIC (10G) Mellanox ConnectX-4 Lx Dual Port 25 GbE DA/SFP rNDC Mellanox ConnectX-4 Lx Dual Port 25 GbE DA/SFP Network Adapter, Low Profile

NOTE: You can install up to three PCIe add-on NIC cards.

VGA ports

The Video Graphic Array (VGA) port enables you to connect the system to a VGA display.

The R640 system supports two 15-pin VGA ports: one each on the front and back of the system.

Serial port

The R640 system supports one serial port on the back panel. This port is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant.

Video specifications The R640 system supports the integrated Matrox G200eW3 graphics controller with 16 MB of video frame buffer.

Table 15. Supported video resolution options

Resolution Refresh rate (Hz) Color depth (bits)

640 x 480 60, 70 8, 16, 32

800 x 600 60, 75, 85 8, 16, 32

22 Technical specifications

Table 15. Supported video resolution options (continued)

Resolution Refresh rate (Hz) Color depth (bits)

1024 x 768 60, 75, 85 8, 16, 32

1152 x 864 60, 75, 85 8, 16, 32

1280 x 1024 60, 75 8, 16, 32

1440 x 900 60 8, 16, 32

1920 x 1200 60 8, 16, 32

Environmental specifications The following tables describe the general environmental specifications for the R640 system.

NOTE: For additional information about environmental certifications, see the Product Environmental Datasheet located

with the Manuals & Documents at https://www.dell.com/poweredgemanuals.

Table 16. Temperature specifications

Temperature Specifications

Storage 40C to 65C (40F to 149F)

Continuous operation (for altitude less than 950 m or 3117 ft)

10C to 35C (50F to 95F) with no direct sunlight on the equipment.

NOTE: Maximum of 205 W, 28 core processor is supported in systems with eight 2.5 inch processor direct attached PCIe SSD drives, and three PCIe slot chassis.

NOTE: Certain configurations may have ambient temperature restrictions. For more information see the Ambient temperature limitations section.

Maximum temperature gradient (operating and storage)

20C/h (68F/h)

Table 17. Relative humidity specifications

Relative humidity Specifications

Storage 5% to 95% RH with 33C (91F) maximum dew point. Atmosphere must be non-condensing at all times.

Operating 10% to 80% relative humidity with 29C (84.2F) maximum dew point.

Table 18. Maximum vibration specifications

Maximum vibration Specifications

Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).

Storage 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).

Table 19. Maximum shock specifications

Maximum shock Specifications

Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 6 G for up to 11 ms.

Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.

Technical specifications 23

Table 20. Maximum altitude specifications

Maximum altitude Specifications

Operating 3048 m (10,000 ft)

Storage 12,000 m (39,370 ft)

Table 21. Operating temperature de-rating specifications

Operating temperature de-rating Specifications

Up to 35C (95F) Maximum temperature is reduced by 1C/300 m (1F/547 ft) above 950 m (3,117 ft).

35C to 40C (95F to 104F) Maximum temperature is reduced by 1C/175 m (1F/319 ft) above 950 m (3,117 ft).

40C to 45C (104F to 113F) Maximum temperature is reduced by 1C/125 m (1F/228 ft) above 950 m (3,117 ft).

Standard operating temperature

The following table lists standard operating temperature specifications.

Table 22. Standard operating temperature specifications

Standard operating temperature Specifications

Continuous operation (for altitude less than 950 m or 3117 ft)

10C to 35C (50F to 95F) with no direct sunlight on the equipment.

Expanded operating temperature

The following table lists expanded operating temperature specifications for the R640 system.

Table 23. Expanded operating temperature specifications

Expanded operating temperature Specifications

Continuous operation 5C40C at 5% to 85% RH with 29C dew point. NOTE: Outside the standard operating temperature (10C35C), the system can operate continuously in temperatures as low as 5C and as high as 40C.

For temperatures between 35C40C, de-rate maximum allowable temperature by 1C per 175 m above 950 m (1F per 319 ft).

1% of annual operating hours 5C45C at 5% to 90% RH with 29C dew point. NOTE: Outside the standard operating temperature (10C35C), the system can operate down to 5C or up to 45C for a maximum of 1% of its annual operating hours.

For temperatures between 40C and 45C, de-rate maximum allowable temperature by 1C per 125 m above 950 m (1F per 228 ft).

NOTE: When operating in the expanded temperature range, system performance may be impacted.

NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported on the LCD

panel and in the System Event Log.

24 Technical specifications

Expanded operating temperature restrictions

The following additional restrictions apply:

Do not perform a cold startup below 5C. The operating temperature specified is for a maximum altitude of 3050 m (10,000 ft). 150 W/8 C, 165 W/12 C and higher wattage processor(TDP>165 W) are not supported. Redundant power supply unit is required. Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported. PCIe SSD is not supported. Rear installed drives are not supported Tape backup unit is not supported.

Ambient temperature limitations

The ambient temperature limit must be adhered to ensure proper cooling and to avoid excess processor throttling, which may impact system performance.

Ambient temperature configurations require ambient temperatures of less than 35C.

Particulate and gaseous contamination specifications

The following table defines the limitations that help avoid any equipment damage or failure from particulate and gaseous contamination. If the levels of particulate or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.

Table 24. Particulate contamination specifications

Particulate contamination Specifications

Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.

NOTE: This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.

NOTE: Air entering the data center must have the MERV11 or MERV13 filtration.

Conductive dust Air must be free of conductive dust, zinc whiskers, or other conductive particles.

NOTE: This condition applies to data center and non-data center environments.

Corrosive dust Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point less

than 60% relative humidity.

NOTE: This condition applies to data center and non-data center environments.

Table 25. Gaseous contamination specifications

Gaseous contamination Specifications

Copper coupon corrosion rate <300 /month per Class G1 as defined by ANSI/ISA71.04-1985.

Silver coupon corrosion rate <200 /month as defined by AHSRAE TC9.9.

NOTE: Maximum corrosive contaminant levels measured at 50% relative humidity.

Technical specifications 25

System diagnostics and indicator codes This section explains the system diagnostics and indicator codes for your system.

Indicator codes The diagnostic indicators on the system front panel display system status during system startup and assist you in diagnosing system health.

Status LED indicators

The status indicators display solid amber if any error occurs on the system.

Table 26. Status LED indicators and descriptions

Icon Description Condition Corrective action

Drive indicator

The indicator turns solid amber if there is a drive error.

Check the System Event Log to determine if the drive has an error.

Run the appropriate Online Diagnostics test. Restart the system and run embedded diagnostics (ePSA).

Temperature indicator

The indicator turns solid amber if the system experiences a thermal error (for example, the ambient temperature is out of range or there is a fan failure).

Ensure that none of the following conditions exist: A cooling fan has been removed or has failed. System cover, air shroud, memory module blank, or back filler

bracket is removed. Ambient temperature is too high. External airflow is obstructed.

If the problem persists, see "Getting help".

Electrical indicator

The indicator turns solid amber if the system experiences an electrical error (for example, voltage out of range, or a failed power supply unit (PSU) or voltage regulator).

Check the System Event Log or system messages for the specific issue. If it is due to a problem with the PSU, check the LED on the PSU. Reseat the PSU.

If the problem persists, see "Getting help".

Memory indicator

The indicator turns solid amber if a memory error occurs.

Check the System Event Log or system messages for the location of the failed memory. Reseat the memory module.

If the problem persists, see "Getting help".

PCIe indicator

The indicator turns solid amber if a PCIe card experiences an error.

Restart the system. Update any required drivers for the PCIe card. Reinstall the card.

If the problem persists, see "Getting help".

3

26 System diagnostics and indicator codes

System health and system ID indicator codes

The system health and system ID indicator is located on the left control panel of your system.

Figure 14. System health and system ID indicators

Table 27. System health and system ID indicator codes

System health and system ID indicator code Condition

Solid blue Indicates that the system is turned on, the system is healthy, and system ID mode is not active. Press the system health and system ID button to switch to system ID mode.

Blinking blue Indicates that the system ID mode is active. Press the system health and system ID button to switch to system health mode.

Solid amber Indicates that the system is in fail-safe mode. If the problem persists, see Getting help on page 35.

Blinking amber Indicates that the system is experiencing a fault. Check the System Event Log or the LCD panel, if available on the bezel, for specific error messages.

iDRAC Quick Sync 2 indicator codes

The iDRAC Quick Sync 2 module (optional) is located on the left control panel of your system.

Figure 15. iDRAC Quick Sync 2 indicators

Table 28. iDRAC Quick Sync 2 indicators and descriptions

iDRAC Quick Sync 2 indicator code

Condition Corrective action

Off (default state) Indicates that the iDRAC Quick Sync 2 feature is turned off. Press the iDRAC Quick Sync 2 button to turn on the iDRAC Quick Sync 2 feature.

If the LED fails to turn on, reseat the left control panel flex cable and check. If the problem persists, see "Getting help."

Solid white Indicates that iDRAC Quick Sync 2 is ready to communicate. Press the iDRAC Quick Sync 2 button to turn off.

If the LED fails to turn off, restart the system. If the problem persists, see Getting help on page 35.

Blinks white rapidly Indicates data transfer activity. If the indicator continues to blink indefinitely, see Getting help on page 35.

Blinks white slowly Indicates that firmware update is in progress.

If the indicator continues to blink indefinitely, see Getting help on page 35.

Blinks white five times rapidly and then turns off

Indicates that the iDRAC Quick Sync 2 feature is disabled.

Check if iDRAC Quick Sync 2 feature is configured to be disabled by iDRAC. If the problem persists, see Getting help on page 35.

Solid amber Indicates that the system is in fail-safe mode.

Restart the system. If the problem persists, see Getting help on page 35.

System diagnostics and indicator codes 27

Table 28. iDRAC Quick Sync 2 indicators and descriptions (continued)

iDRAC Quick Sync 2 indicator code

Condition Corrective action

Blinking amber Indicates that the iDRAC Quick Sync 2 hardware is not responding properly.

Restart the system. If the problem persists, see Getting help on page 35.

iDRAC Direct LED indicator codes

The iDRAC Direct LED indicator lights up to indicate that the port is connected and is being used as a part of the iDRAC subsystem.

You can configure iDRAC Direct by using a USB-to-micro USB (type AB) cable, which you can connect to your laptop or tablet. The following table describes iDRAC Direct activity when the iDRAC Direct port is active:

Table 29. iDRAC Direct LED indicator codes

iDRAC Direct LED indicator code

Condition

Solid green for two seconds

Indicates that the laptop or tablet is connected.

Flashing green (on for two seconds and off for two seconds)

Indicates that the laptop or tablet connected is recognized.

Turns off Indicates that the laptop or tablet is unplugged.

NIC indicator codes

Each NIC on the back of the system has indicators that provide information about the activity and link status. The activity LED indicator indicates if data is flowing through the NIC, and the link LED indicator indicates the speed of the connected network.

Figure 16. NIC indicator codes

1. Link LED indicator 2. Activity LED indicator

Table 30. NIC indicator codes

Status Condition

Link and activity indicators are off. The NIC is not connected to the network.

Link indicator is green, and activity indicator is blinking green.

The NIC is connected to a valid network at its maximum port speed, and data is being sent or received.

Link indicator is amber, and activity indicator is blinking green.

The NIC is connected to a valid network at less than its maximum port speed, and data is being sent or received.

Link indicator is green, and activity indicator is off. The NIC is connected to a valid network at its maximum port speed, and data is not being sent or received.

Link indicator is amber, and activity indicator is off. The NIC is connected to a valid network at less than its maximum port speed, and data is not being sent or received.

Link indicator is blinking green, and activity is off. NIC identify is enabled through the NIC configuration utility.

28 System diagnostics and indicator codes

Power supply unit indicator codes

AC power supply units (PSUs) have an illuminated translucent handle that serves as an indicator. The indicator shows whether power is present or a power fault has occurred.

For more information about the PSU specifications, see the technical specifications for your system.

For information about the event and error messages generated during POST, see the Dell Event and Error Messages Reference Guide at https://www.dell.com/openmanagemanuals.

Figure 17. AC PSU status indicator

1. AC PSU status indicator/handle

Table 31. AC PSU status indicator codes

Power indicator codes Condition

Green A valid power source is connected to the PSU, and the PSU is operational.

Blinking amber Indicates a problem with the PSU.

Not illuminated Power is not connected to the PSU.

Blinking green When the firmware of the PSU is being updated, the PSU handle blinks green.

CAUTION: Do not disconnect the power cable, or unplug the PSU when updating firmware. If a firmware update is interrupted, the PSUs do not function.

Blinking green and turns off When hot-plugging a PSU, the PSU handle blinks green five times at a rate of 4 Hz and turns off. This indicates a PSU mismatch regarding efficiency, feature set, health status, or supported voltage.

CAUTION: If two PSUs are installed, both the PSUs must have the same type of label; for example, the Extended Power Performance (EPP) label. Mixing PSUs from previous generations of systems based on PowerEdge servers is not supported, even if the PSUs have the same power rating. This results in a PSU mismatch condition, or failure to turn on the system.

CAUTION: When correcting a PSU mismatch, replace only the PSU with the blinking indicator. Swapping the PSU to make a matched pair can result in an error condition and unexpected system shutdown. To change from a high output configuration to a low output configuration or conversely, you must turn off the system. AC PSUs support both 240 V and 120 V input voltages except for Titanium PSUs, which support only 240 V. When two identical PSUs receive

System diagnostics and indicator codes 29

Table 31. AC PSU status indicator codes (continued)

Power indicator codes Condition

different input voltages, they can output different wattages and trigger a mismatch.

CAUTION: If two PSUs are used, they must be of the same type and have the same maximum output power.

Drive indicator codes

The LEDs on the drive carrier indicate the state of each drive. Each drive carrier in your system has two LEDs: an activity LED (green) and a status LED (bicolor, green/amber). The activity LED flashes whenever the drive is accessed. The status LED indicator indicates the power condition of the drive.

Figure 18. Drive indicators on the drive and the mid drive tray backplane

1. Drive activity LED indicator 2. Drive status LED indicator 3. Drive capacity label

NOTE: If the drive is in the Advanced Host Controller Interface (AHCI) mode, the status LED indicator does not turn on.

Table 32. Drive indicator codes

Drive status indicator code Condition

Flashes green twice per second Identifying drive or preparing for removal.

Off Drive ready for removal. NOTE: The drive status indicator remains off until all drives are initialized after the system is turned on. Drives are not ready for removal during this time.

Flashes green, amber, and then turns off Predicted drive failure.

Flashes amber four times per second Drive failed.

Flashes green slowly Drive rebuilding.

Solid green Drive online.

Flashes green for three seconds, amber for three seconds, and then turns off after six seconds

Rebuild stopped.

30 System diagnostics and indicator codes

Using system diagnostics If you experience a problem with your system, run the system diagnostics before contacting Dell EMC for technical assistance. The purpose of running system diagnostics is to test your system hardware without using additional equipment or risking data loss. If you are unable to fix the problem yourself, service and support personnel can use the diagnostics results to help you solve the problem.

Dell Embedded System Diagnostics

The Embedded System Diagnostics provides a set of options for particular device groups or devices.

Also known as Enhanced Pre-boot System Assessment (ePSA) diagnostics, Embedded System Diagnostics allows you to:

Run tests automatically or in an interactive mode Repeat tests Display or save test results Run thorough tests to introduce additional test options to provide extra information about the failed device(s) View status messages that inform you if tests are completed successfully View error messages that inform you of problems encountered during testing

Running Embedded System Diagnostics from Boot Manager

If your system does not boot., run the Embedded System Diagnostics (ePSA).

Steps

1. While the system is booting, press F11.

2. Use the keyboard arrows to select System Utilities > Launch Diagnostics.

Results

The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics starts executing the tests on all the detected devices.

Running Embedded System Diagnostics from the Dell Lifecycle Controller

Perform the following steps to run the Embedded System Diagnostics from the Dell Lifecycle Controller.

Steps

1. While the system is booting, press F10.

2. Select Hardware Diagnostics > Run Hardware Diagnostics. The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics starts executing the tests on all the detected devices.

Results

The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics starts executing the tests on all the detected devices.

System diagnostic controls

Configuration Displays the configuration and status information of all detected devices.

Results Displays the results of all tests that are run.

System health Provides the current overview of the system performance.

System diagnostics and indicator codes 31

Event log Displays a time-stamped log of the results of all tests run on the system. This is displayed if at least one event description is recorded.

32 System diagnostics and indicator codes

Reference material This section contains additional information that may be required for the procedures described in this document.

Trusted Platform Module The Trusted Platform Module (TPM) is a dedicated microprocessor designed to secure hardware by integrating cryptographic keys into devices. Software can use a TPM to authenticate hardware devices.

Because each TPM chip contains a unique and secret RSA key embedded during the TPM's manufacture, the TPM is capable of performing platform authentication.

The TPM must be replaced only while installing a new system board.

Upgrading the Trusted Platform Module

Prerequisites

Follow all safety guidelines. Ensure that your operating system supports the version of the TPM being installed. Ensure that you download and install the latest BIOS firmware on your system. Ensure that the BIOS is configured to enable UEFI boot mode.

About this task

CAUTION: If you are using the Trusted Platform Module (TPM) with an encryption key, you may be prompted

to create a recovery key during program or System Setup. Ensure that you create and safely store this recovery

key. If you replace this system board, you must supply the recovery key when you restart your system or

program before you can access the encrypted data on your hard drives.

CAUTION: After the TPM plug-in module is installed, it is cryptographically bound to that specific system board.

Any attempt to remove an installed TPM plug-in module breaks the cryptographic binding, the removed TPM

cannot be reinstalled or installed on another system board.

Initialize the TPM for BitLocker users

Steps

Initialize the TPM.

For more information, see https://technet.microsoft.com/en-us/library/cc753140.aspx.

The TPM Status changes to Enabled, Activated.

Initialize the TPM 1.2 for TXT users

Steps

1. While booting the system, press F2 to enter System Setup.

2. In the System Setup Main Menu screen, click System BIOS > System Security Settings.

3. From the TPM Security option, select On with Pre-boot Measurements.

4. From the TPM Command option, select Activate.

4

Reference material 33

5. Save the settings.

6. Restart the system.

7. Enter System Setup again.

8. On the System Setup Main Menu screen, click System BIOS > System Security Settings.

9. From the Intel TXT option, select On.

34 Reference material

Getting help This section explains the different resources available for getting help for your system.

Contacting Dell EMC Use this topic to learn how to contact Dell EMC.

About this task

Dell EMC provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell EMC for sales, technical support, or customer service issues use the steps in this task.

NOTE: If you do not have an active internet connection, you can find contact information on your purchase invoice, packing

slip, bill, or Dell EMC product catalog.

Steps

1. Go to https://dell.com/support/incidents-online/contactus.

2. For customized support:

a. Type your system Service Tag in the Service Tag box. b. Click Submit.

3. For general support:

a. Select your product category. b. Select your product segment. c. Select your product.

The support page that lists the various support categories is displayed.

Example

Secure Remote Services Secure Remote Services (formerly ESRS) is a secure, two-way connection between Dell EMC products and Dell EMC Customer Support that helps customers avoid and resolve issues up to 73 percent faster. There is also an email alert for this. It is completely virtual and offers flexibility for enterprise environments of any size.

Key benefits

Proactive wellness monitoring and issue prevention Automated issue detection, notification and case creation for quicker uptime Predictive analytics-based recommendations through MyService360 and product consoles

The Secure Remote Services lifeline is a heartbeat that pulses outbound from the Secure Remote Services gateway to Dell EMC Customer Service in 30-second intervals, providing Dell EMC with connectivity status as well as the status of each product. The heartbeat ensures continuous monitoring, notification, and if necessary, proactive remote troubleshooting to ensure high availability of your products. As a result, you will experience faster resolution and greater uptime.

Recycling or End-of-Life service information Take back and recycling services are offered for this product in certain countries.

If you want to dispose of system components, visit Dell.com/recyclingworldwide and select the relevant co

Manualsnet FAQs

If you want to find out how the R640 Dell works, you can view and download the Dell VxFlex R640 Solution Owner's Guide on the Manualsnet website.

Yes, we have the Owner's Guide for Dell R640 as well as other Dell manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Owner's Guide should include all the details that are needed to use a Dell R640. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Dell VxFlex R640 Solution Owner's Guide is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Dell VxFlex R640 Solution Owner's Guide consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Dell VxFlex R640 Solution Owner's Guide free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Dell VxFlex R640 Solution Owner's Guide, simply download the document to your computer. Once downloaded, open the PDF file and print the Dell VxFlex R640 Solution Owner's Guide as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.