Dell DSS 1510 Owner's Manual

Regulatory Model: E28S Series Regulatory Type: E28S002

Notes, cautions, and warnings

NOTE: A NOTE indicates important information that helps you make better use of your computer.

CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the

problem.

WARNING: A WARNING indicates a potential for property damage, personal injury, or death.

2016 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.

2016 - 05

Rev. A02

1 Dell DSS 1510 system overview...................................................................................................... 7 Supported configurations for the Dell DSS 1510 system..................................................................................................8 Front panel features..............................................................................................................................................................9

Front panel features of a 4 x 3.5-inch hard drive chassis.......................................................................................... 9 Front panel features of a 8 x 2.5-inch hard drive chassis.........................................................................................10 Front panel features of a 4 x 3.5-inch cabled hard drive chassis............................................................................. 11

Back panel features.............................................................................................................................................................. 11 Back panel features........................................................................................................................................................12

Diagnostic Indicators............................................................................................................................................................13 Diagnostic indicators on the front panel......................................................................................................................13 Hard drive indicator codes............................................................................................................................................ 14 NIC indicator codes........................................................................................................................................................15 Redundant power supply unit indicator codes........................................................................................................... 15 Non-redundant power supply unit indicator codes.................................................................................................... 17

Locating Service Tag of your system................................................................................................................................ 17

2 Documentation resources............................................................................................................ 18

3 Technical specifications.............................................................................................................. 19 Chassis dimensions.............................................................................................................................................................. 19 Chassis weight......................................................................................................................................................................19 Processor specifications......................................................................................................................................................19 PSU specifications.............................................................................................................................................................. 20 System battery specifications........................................................................................................................................... 20 Expansion bus specifications............................................................................................................................................. 20 Memory specifications........................................................................................................................................................20 Storage controller specifications.......................................................................................................................................20 Remote management port................................................................................................................................................. 20 Drive specifications.............................................................................................................................................................. 21

Hard drives...................................................................................................................................................................... 21 Ports and connectors specifications..................................................................................................................................21

USB ports........................................................................................................................................................................ 21 NIC ports......................................................................................................................................................................... 21 Serial connector..............................................................................................................................................................21 VGA port..........................................................................................................................................................................21

Video specifications............................................................................................................................................................. 21 Environmental specifications.............................................................................................................................................. 21

Particulate and gaseous contamination specifications............................................................................................. 22

4 Initial system setup and configuration.......................................................................................... 24 Setting up your system.......................................................................................................................................................24 Options to set up BMC IP address....................................................................................................................................24 Log in to BMC......................................................................................................................................................................24 Options to install the operating system............................................................................................................................25

Contents

Contents 3

Methods to download firmware and drivers.............................................................................................................. 25

5 Pre-operating system management applications........................................................................... 26 Options to manage the pre-operating system applications........................................................................................... 26 System Setup.......................................................................................................................................................................26

Viewing System Setup..................................................................................................................................................26 System Setup details.....................................................................................................................................................27 System BIOS.................................................................................................................................................................. 27 iDRAC Settings utility.................................................................................................................................................... 47 Device Settings..............................................................................................................................................................48

Boot Manager...................................................................................................................................................................... 48 Viewing Boot Manager..................................................................................................................................................49 Boot Manager main menu............................................................................................................................................ 49

PXE boot.............................................................................................................................................................................. 50

6 Installing and removing system components................................................................................. 51 Safety instructions............................................................................................................................................................... 51 Before working inside your system....................................................................................................................................51 After working inside your system...................................................................................................................................... 52 Recommended tools........................................................................................................................................................... 52 System cover....................................................................................................................................................................... 52

Removing the system cover........................................................................................................................................ 52 Installing the system cover...........................................................................................................................................53

Inside the system.................................................................................................................................................................55 Cooling shroud.....................................................................................................................................................................56

Removing the cooling shroud...................................................................................................................................... 56 Installing the cooling shroud......................................................................................................................................... 57

System memory...................................................................................................................................................................58 General memory module installation guidelines......................................................................................................... 59 Mode-specific guidelines.............................................................................................................................................. 60 Sample memory configurations................................................................................................................................... 60 Removing memory modules..........................................................................................................................................61 Installing memory modules........................................................................................................................................... 63

Hard drives........................................................................................................................................................................... 64 Removing a 3.5-inch hard drive blank.........................................................................................................................64 Installing a 3.5-inch hard drive blank...........................................................................................................................65 Removing a 3.5-inch cabled hard drive carrier..........................................................................................................66 Installing a 3.5-inch cabled hard drive carrier.............................................................................................................67 Removing a hot swappable hard drive carrier........................................................................................................... 68 Installing a hot-swappable hard drive carrier............................................................................................................. 69 Installing a 2.5-inch hard drive into a 3.5-inch hard drive adapter.......................................................................... 70 Removing a 2.5-inch hard drive from a 3.5-inch hard drive adapter.......................................................................71 Installing a 3.5-inch hard drive adapter into a hot swap hard drive carrier............................................................ 72 Removing a 3.5-inch hot swappable hard drive adapter from a 3.5-inch hot swappable hard drive carrier.....73 Removing a hot swappable hard drive from a hard drive carrier.............................................................................74 Installing a hot swappable hard drive into a hard drive carrier.................................................................................75

Cooling fans..........................................................................................................................................................................75 Removing a cooling fan.................................................................................................................................................76 Installing a cooling fan....................................................................................................................................................77

4 Contents

Expansion cards and expansion card riser........................................................................................................................78 Expansion card installation guidelines..........................................................................................................................78 Removing the expansion card riser............................................................................................................................. 78 Installing the expansion card riser................................................................................................................................79 Removing an expansion card....................................................................................................................................... 80 Installing an expansion card...........................................................................................................................................81

Remote management port card (optional)...................................................................................................................... 82 Removing the optional remote management port card............................................................................................82 Installing the optional remote management port card..............................................................................................84

Processors and heat sinks..................................................................................................................................................85 Removing a heat sink.................................................................................................................................................... 85 Removing a processor...................................................................................................................................................87 Installing a processor.....................................................................................................................................................90 Installing a heat sink....................................................................................................................................................... 91

Power supply units.............................................................................................................................................................. 94 Hot spare feature.......................................................................................................................................................... 94 Removing a redundant power supply unit..................................................................................................................95 Installing a redundant power supply unit.................................................................................................................... 96 Removing a cabled power supply unit.........................................................................................................................97 Installing a cabled power supply unit...........................................................................................................................98 Removing the power supply unit blank.......................................................................................................................99 Installing the power supply unit blank........................................................................................................................100

System battery...................................................................................................................................................................100 Replacing the system battery.....................................................................................................................................100

Hard drive backplane......................................................................................................................................................... 102 Removing the hard drive backplane.......................................................................................................................... 102 Installing the hard drive backplane.............................................................................................................................106

Control panel.......................................................................................................................................................................107 Removing the control panel........................................................................................................................................ 107 Installing the control panel.......................................................................................................................................... 109 Removing the control panel module........................................................................................................................... 110 Installing the control panel module............................................................................................................................. 112

Power interposer board..................................................................................................................................................... 114 Removing the power interposer board...................................................................................................................... 114 Installing the power interposer board.........................................................................................................................115

System board...................................................................................................................................................................... 116 Removing the system board........................................................................................................................................116 Installing the system board.......................................................................................................................................... 118

7 Using system diagnostics...........................................................................................................122 Dell Embedded System Diagnostics................................................................................................................................ 122

Running the Embedded System Diagnostics from Boot Manager........................................................................ 122 System diagnostic controls......................................................................................................................................... 122

8 Jumpers and connectors ........................................................................................................... 123 System board jumper settings..........................................................................................................................................123 Disabling a forgotten password........................................................................................................................................123 System board connectors and jumpers...........................................................................................................................124

Contents 5

9 Troubleshooting your system..................................................................................................... 126 Troubleshooting system startup failure...........................................................................................................................126 Troubleshooting external connections............................................................................................................................ 126 Troubleshooting the video subsystem............................................................................................................................ 126 Troubleshooting a USB device......................................................................................................................................... 127 Troubleshooting a serial I/O device................................................................................................................................. 127 Troubleshooting a NIC.......................................................................................................................................................128 Troubleshooting a wet system......................................................................................................................................... 128 Troubleshooting a damaged system................................................................................................................................129 Troubleshooting the system battery............................................................................................................................... 130 Troubleshooting power supply units.................................................................................................................................131

Troubleshooting power source problems...................................................................................................................131 Power supply unit problems........................................................................................................................................ 131

Troubleshooting cooling problems................................................................................................................................... 132 Troubleshooting cooling fans............................................................................................................................................132 Troubleshooting system memory.....................................................................................................................................133 Troubleshooting a hard drive............................................................................................................................................ 134 Troubleshooting a storage controller...............................................................................................................................134 Troubleshooting expansion cards.................................................................................................................................... 135 Troubleshooting processors............................................................................................................................................. 136

10 Getting help............................................................................................................................ 137 Contacting Dell................................................................................................................................................................... 137 Documentation feedback.................................................................................................................................................. 137

6 Contents

Dell DSS 1510 system overview The Dell DSS 1510 rack servers support up to:

One Intel Xeon EP E5-2600 v4, E5-2600 v3, E5-1600 v4, or E5-1600 v3 processor 4 x 3.5-inch cabled hard drives with non-redundant power supply unit (PSU) or 4 x 3.5-inch hot swappable hard drives with redundant

PSU or 8 x 2.5-inch hot swappable hard drives/SSDs with redundant PSU Eight DIMMs supporting up to 512 MB of memory Two AC redundant or one AC cabled PSUs

Topics:

Supported configurations for the Dell DSS 1510 system Front panel features Back panel features Diagnostic Indicators Locating Service Tag of your system

1

Dell DSS 1510 system overview 7

Supported configurations for the Dell DSS 1510 system

Figure 1. Supported configurations for the DSS 1510 system

8 Dell DSS 1510 system overview

Front panel features The front panel provides access to the features available on the front of the server, such as the power button, NMI button, system identification tag, system identification button, and USB and VGA ports. The hot swappable hard drives are accessible from the front panel.

Front panel features of a 4 x 3.5-inch hard drive chassis

Figure 2. Front panel features of a 4 x 3.5-inch hard drive chassis

1. Power button 2. Diagnostic indicator

3. Information tag 4. Hard drives

Table 1. Front panel features of a 4 x 3.5-inch hard drive chassis

Item Indicator, Button, or Connector

Icon Description

1 Power button Press the power button to turn the system on or off. The indicator on the button indicates if the system is on or off.

NOTE: To gracefully shut down an ACPI-compliant operating system, press the power button.

2 Diagnostic indicator The diagnostic indicator lights up to display error status. For more information, see the Diagnostic indicators section.

3 Information tag Displays system information such as service tag, NIC, and MAC address.

NOTE: The information tag is a slide-out label panel.

4 Hard drives Up to four 3.5-inch hot swappable hard drives/SSDs.

For information about the supported hard drives, see the Technical specifications section.

Related reference

Diagnostic indicators on the front panel

Technical specifications

Dell DSS 1510 system overview 9

Front panel features of a 8 x 2.5-inch hard drive chassis

Figure 3. Front panel features of a 8 x 2.5-inch hard drive chassis

1. Power button 2. Diagnostic indicator

3. Information tag 4. Hard drives

Table 2. Front panel features of a 8 x 2.5-inch hard drive chassis

Item Indicator, Button, or Connector

Icon Description

1 Power button Press the power button to turn the system on or off. The indicator on the button indicates if the system is on or off.

NOTE: To gracefully shut down an ACPI-compliant operating system, press the power button.

2 Diagnostic indicator The diagnostic indicator lights up to display error status. For more information, see the Diagnostic indicators section.

3 Information tag Displays system information such as service tag, NIC, and MAC address.

NOTE: The information tag is a slide-out label panel.

4 Hard drives Up to eight 2.5-inch hot swappable hard drives/SSDs.

For information about the supported hard drives, see the Technical specifications section.

Related reference

Diagnostic indicators on the front panel

Technical specifications

10 Dell DSS 1510 system overview

Front panel features of a 4 x 3.5-inch cabled hard drive chassis

Figure 4. Front panel features of a 4 x 3.5-inch cabled hard drive chassis

1. Power button 2. Diagnostic indicators

3. Information tag 4. Hard drives

Table 3. Front panel features of a 4 x 3.5-inch cabled hard drive chassis

Item Indicator, Button, or Connector

Icon Description

1 Power button Press the power button to turn the system on or off. The indicator on the button indicates if the system is on or off.

NOTE: To gracefully shut down an ACPI-compliant operating system, press the power button.

2 Diagnostic indicators The diagnostic indicator lights up to display error status. For more information, see the Diagnostic indicators section.

3 Information tag Displays system information such as service tag, NIC, and MAC address.

NOTE: The information tag is a slide-out label panel.

4 Hard drives Up to four 3.5-inch cabled hard drives.

For information about the supported hard drives, see the Technical specifications section.

Related reference

Diagnostic indicators on the front panel

Technical specifications

Back panel features The back panel provides access to the features available on the back of the server, such as the system identification button, power supply sockets, cable management arm connectors, NIC ports, and USB and VGA ports. A majority of the expansion card ports can be accessed from the back panel. The hot swappable and cabled power supply units are accessible from the back panel.

Dell DSS 1510 system overview 11

Back panel features

Figure 5. Back panel features

1. Serial connector 2. BMC port (optional)

3. PCIe expansion card slot (2) 4. Power supply unit (PSU1 and PSU2)

5. Ethernet port (2) 6. System identification button

7. System identification port 8. USB 3.0 port

9. USB 2.0 port 10. Video/VGA port

Table 4. Back panel features

Item Indicator, Button, or Connector Icon Description

1 Serial connector Use the serial port to connect a serial device to the system. For more information about the supported serial port, see the Technical specifications section.

2 BMC port (optional)

Dedicated management port on the BMC port card.

3 PCIe expansion card slot (2)

Allows you to connect a PCI Express expansion card.

4 Power supply unit (PSU1 and PSU2)

Redundant power supply

Up to two 550 W redundant AC PSUs.

Non-redundant power supply

One 450 W non-redundant AC PSU. NOTE: Non-redundant PSU is supported in systems with cabled hard drives.

NOTE: For non-redundant PSUs, there is only one power supply socket.

5 Ethernet port (2) Use the Ethernet port to connect Local Area Networks (LANs) to the system. For more information about the supported Ethernet ports, see the Technical specifications section.

6 System identification button

Press the system ID button:

To locate a particular system within a rack. To turn the system ID on or off.

NOTE: To reset the BMC (if not disabled in System Setup), press and hold the button for more than 15 seconds.

NOTE: If the system stops responding during POST, press and hold the system ID button (for more than five seconds) to enter the BIOS progress mode.

12 Dell DSS 1510 system overview

Item Indicator, Button, or Connector Icon Description

7 System identification port

Use the system identification port to connect the system status indicator assembly through the optional cable management arm.

8 USB 3.0 port Use the USB 3.0 port to connect USB devices to the system. These ports are 9-pin, USB 3.0 compliant.

9 USB 2.0 port Use the USB 2.0 port to connect USB devices to the system. These ports are 4-pin, USB 2.0 compliant.

10 Video/VGA port Use the video/VGA port to connect a display to the system. For more information about the supported video/VGA port, see the Technical specifications section.

Related reference

Technical specifications

Diagnostic Indicators The diagnostic indicators on the system front panel display error status during system startup.

Diagnostic indicators on the front panel The diagnostic indicators on the system front panel display error status during system startup.

NOTE: No diagnostic indicators are lit when the system is turned off. To turn on the system, plug it into a working

power source and press the power button.

Table 5. Diagnostic indicators

Icon Description Condition Corrective action

Health indicator The indicator turns solid blue if the system is in good health.

None required.

The indicator blinks amber:

When the system is turned on. When the system is in standby. If any error condition exists. For

example, a failed fan, power supply unit (PSU), or a hard drive.

Check the System Event Log or system messages for the specific issue. For more information about error messages, see the Dell Event and Error Messages Reference Guide at Dell.com/openmanagemanuals > OpenManage software.

The POST process is interrupted without any video output due to invalid memory configurations. See the Getting help section.

Related reference

Getting help

Dell DSS 1510 system overview 13

Hard drive indicator codes Each hard drive carrier has an activity indicator and a status indicator. The indicators provide information about the current status of the hard drive. The activity LED indicates whether hard drive is currently in use or not. The status LED indicates the power condition of the hard drive.

Figure 6. Hard drive indicators

1. hard drive activity indicator 2. hard drive status indicator 3. hard drive

NOTE: If the hard drive is in the Advanced Host Controller Interface (AHCI) mode, the status indicator (on the right

side) does not turn on.

Table 6. Hard drive indicator codes

Drive-status indicator pattern (RAID only) Condition

Flashes green twice per second Identifying drive or preparing for removal.

Off Drive ready for insertion or removal. NOTE: The drive status indicator remains off until all hard drives are initialized after the system is turned on. Drives are not ready for insertion or removal during this time.

Flashes green, amber, and then turns off Predicted drive failure

Flashes amber four times per second Drive failed

Flashes green slowly Drive rebuilding

Steady green Drive online

Flashes green for three seconds, amber for three seconds, and then turns off after six seconds

Rebuild stopped

14 Dell DSS 1510 system overview

NIC indicator codes Each NIC on the back panel has an indicator that provides information about the network activity and link status. The activity LED indicates whether the NIC is currently connected or not. The link LED indicates the speed of the connected network.

Figure 7. NIC indicators

1. link indicator 2. activity indicator

Table 7. NIC indicators

Convention Status Condition

A Link and activity indicators are off The NIC is not connected to the network.

B Link indicator is green The NIC is connected to a valid network at its maximum port speed (1 Gbps).

C Link indicator is amber The NIC is connected to a valid network at less than its maximum port speed.

D Activity indicator is flashing green Network data is being sent or received.

Redundant power supply unit indicator codes Each AC power supply unit (PSU) has an illuminated translucent handle that indicates whether power is present or whether a power fault has occurred.

Dell DSS 1510 system overview 15

Figure 8. AC PSU status indicator

1. AC PSU status indicator/handle

Figure 9. AC PSU status indicator

1. AC PSU status indicator/handle

Table 8. AC PSU status indicator

Convention Power Indicator Pattern

Description

A Green A valid power source is connected to the PSU and the PSU is operational.

B Flashing green When the firmware of the PSU is being updated, the PSU handle flashes green. CAUTION: Do not disconnect the power cord or unplug the PSU when updating firmware. If firmware update is interrupted, the PSUs will not function.

C Flashes green and turns off

When hot-adding a PSU, the PSU handle flashes green five times at 4 Hz rate and turns off. This indicates that there is a PSU mismatch with respect to efficiency, feature set, health status, and supported voltage.

CAUTION: For AC PSUs, use only PSUs with the Extended Power Performance (EPP) label on the back.

16 Dell DSS 1510 system overview

Convention Power Indicator Pattern

Description

NOTE: Ensure that both the PSUs are of the same capacity.

NOTE: Mixing PSUs from previous generations of Dell servers can result in a PSU mismatch condition or failure to turn the system on.

D Flashing amber Indicates a problem with the PSU. CAUTION: When correcting a PSU mismatch, replace only the PSU with the flashing indicator. Swapping the other PSU to make a matched pair can result in an error condition and unexpected system shutdown. To change from a High Output configuration to a Low Output configuration or vice versa, you must turn off the system.

CAUTION: AC PSUs support both 220 V and 110 V input voltages with the exception of Titanium PSUs, which support only 220 V. When two identical PSUs receive different input voltages, they can output different wattages, and trigger a mismatch.

CAUTION: If two PSUs are used, they must be of the same type and have the same maximum output power.

E Not lit Power is not connected.

Non-redundant power supply unit indicator codes Press the self-diagnostic button to perform a quick health check on the non-redundant power supply unit (PSU) of the system.

Figure 10. Non-redundant AC PSU status indicator and self-diagnostic button

1. self-diagnostic button 2. AC PSU status indicator

Table 9. Non-redundant AC PSU status indicator

Power Indicator Pattern Condition

Not lit Power is not connected or PSU is faulty.

Green A valid power source is connected to the PSU and the PSU is operational.

Locating Service Tag of your system Your system is identified by a unique Express Service Code and Service Tag number. The Express Service Code and Service Tag are found on the front of the system by pulling out the information tag. Alternatively, the information may be on a sticker on the chassis of the system. This information is used by Dell to route support calls to the appropriate personnel.

Dell DSS 1510 system overview 17

Documentation resources This section provides information about the documentation resources for your system.

Table 10. Documentation resources for system

Task Document Location

Setting up your system For information about installing the system into a rack, see the Rack documentation included with your rack solution.

Dell.com/dssmanuals

For information about turning on the system and the technical specifications of your system, see the Getting Started With Your System that shipped with your system.

Dell.com/dssmanuals

Configuring your system For information about BMC features, configuring and logging in to BMC, and managing your system remotely, see the Integrated Dell Remote Access Controller User's Guide.

Dell.com/idracmanuals

For information about installing the operating system, see the operating system documentation.

Dell.com/operatingsystemmanuals

For understanding Remote Access Controller Admin (RACADM) subcommands and supported RACADM interfaces, see the RACADM Command Line Reference Guide for iDRAC.

Dell.com/idracmanuals

For information about updating drivers and firmware, see the Methods to download firmware and drivers section in this document.

Dell.com/support/drivers

Working with Dell PowerEdge RAID controllers

For understanding the features of the Dell PowerEdge RAID controllers (PERC) and deploying the PERC cards, see the Storage controller documentation.

Dell.com/storagecontrollermanuals

Understanding event and error messages

For information about checking the event and error messages generated by the system firmware and agents that monitor system components, see the Dell Event and Error Messages Reference Guide.

Dell.com/openmanagemanuals > OpenManage software

BMC FAQs For frequently asked questions about BMC, see the Dell BMC FAQ guide.

Dell.com/dssmanuals

2

18 Documentation resources

Technical specifications

Chassis dimensions

Figure 11. Chassis dimensions of Dell DSS 1510 system

Table 11. Dimensions of Dell DSS 1510 system

System X Xa Y Z Za Zb

Dell DSS 1510 482.4 mm (18.9 inches)

434.0 mm (17.08 inches)

42.8 mm (1.68 inches)

660.4 mm (26 inches)

18.0 mm (0.70 inches)

642.4 mm (25.29 inches)

Chassis weight Table 12. Chassis weight

System Maximum weight

Four hard drive systems 19.3 kg (42.6 lb)

Eight hard drive systems 19.9 kg (43.7 lb)

Processor specifications The DSS 1510 system supports up to one Intel Xeon EP E5-2600 v4, E5-2600 v3, E5-1600 v4, or E5-1600 v3 product family processor.

3

Technical specifications 19

PSU specifications The DSS 1510 system supports up to two AC power supply units (PSUs).

Table 13. PSU specifications

PSU Class Heat dissipation (maximum)

Frequency Voltage Current

450 W AC Platinum 1871 BTU/hr 50/60 Hz 100240 V AC, autoranging

6.5 A-3.5 A

550 W AC Platinum 2107 BTU/hr 50/60 Hz 100240 V AC, autoranging

7.4 A-3.7 A

NOTE: Heat dissipation is calculated by using the PSU wattage rating.

NOTE: This system is also designed to connect to the IT power systems with a phase to phase voltage not exceeding

230 V.

System battery specifications The DSS 1510 system supports CR 2032 3.0-V lithium coin cell system battery.

Expansion bus specifications The DSS 1510 system supports PCI express (PCIe) generation 1, 2 and 3 expansion cards. The following table provides riser configurations for DSS 1510 systems:

Table 14. Expansion card riser specifications

Expansion card riser PCIe slot on the riser Height Length Link

PCIE_G3_X8 Slot 1 Half Height Half Length x8

Slot 2 Half Height Half Length x8

NOTE: The expansion cards are not hot swappable.

Memory specifications The DSS 1510 system supports DDR4 registered, Error Correcting Code (ECC) Spare Rank, Single Device Data Correction (SDDC) RDIMMs at 1866 MT/s, 2133 MT/s, or 2400 MT/s.

Table 15. Memory specifications

Memory module sockets Memory capacity Minimum RAM Maximum RAM

Eight 288-pins 8 GB, 16 GB, 32 GB or 64 GB single or dual rank (RDIMMs)

8 GB with single processor Up to 512 GB with single processor

Storage controller specifications The DSS 1510 system supports PERC H330, PERC H730, and PERC H730P storage controllers.

Remote management port The DSS 1510 system supports one dedicated 1Gbe Ethernet port with optional card and up to two optional shared NIC ports.

20 Technical specifications

Drive specifications

Hard drives The DSS 1510 system supports:

Up to four 3.5-inch cabled hard drives Up to four 3.5-inch hot swappable SAS, SATA, or Nearline SAS hard drives Up to eight 2.5-inch, hot swappable SAS, SATA, SATA SSD, or Nearline SAS hard drives

Ports and connectors specifications

USB ports The DSS 1510 system supports one 9-pin, USB 3.0 and one 4-pin USB 2.0-compliant ports on the back panel.

NIC ports The DSS 1510 system supports two 10/100/1000 Mbps Network Interface Controller (NIC) ports on the back panel.

Serial connector The serial connector connects a serial device to the system. The DSS 1510 system supports one serial connector on the back panel, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant.

VGA port The Video Graphic Array (VGA) port enables you to connect the system to a VGA display. The DSS 1510 system supports one 15-pin VGA port on the back panel.

Video specifications The DSS 1510 system supports Integrated Matrox G200 graphics card with 16 MB capacity.

Environmental specifications NOTE: For additional information about environmental measurements for specific system configurations, see Dell.com/

environmental_datasheets.

Table 16. Temperature specifications

Temperature Specifications

Storage 40C to 65C (40F to 149F)

Continuous operation (for altitude less than 950 m or 3117 ft) 10C to 35C (50F to 95F) with no direct sunlight on the equipment.

NOTE: Maximum of 145 W 22 core processor is supported in systems with eight 2.5-inches drives, two PCI slot chassis, and 75 W single wide active GPU.

Maximum temperature gradient (operating and storage) 20C/h (36F/h)

Technical specifications 21

Table 17. Relative humidity specifications

Relative humidity Specifications

Storage 5% to 95% RH with 33C (91F) maximum dew point. Atmosphere must be non-condensing at all times.

Operating 10% to 80% relative humidity with 29C (84.2F) maximum dew point.

Table 18. Maximum vibration specifications

Maximum vibration Specifications

Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).

Storage 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).

Table 19. Maximum shock specifications

Maximum shock Specifications

Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms.

Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.

Table 20. Maximum altitude specifications

Maximum altitude Specifications

Operating 30482000 m (10,0006560 ft)

Storage 12,000 m (39,370 ft)

Table 21. Operating temperature de-rating specifications

Operating temperature de-rating Specifications

Up to 35C (95F) Maximum temperature is reduced by 1C/300 m (1F/547 ft) above 950 m (3,117 ft).

35C to 40C (95F to 104F) Maximum temperature is reduced by 1C/175 m (1F/319 ft) above 950 m (3,117 ft).

40C to 45C (104F to 113F) Maximum temperature is reduced by 1C/125 m (1F/228 ft) above 950 m (3,117 ft).

Particulate and gaseous contamination specifications The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous contamination. If the level of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you may need to rectify the environmental conditions. Re-mediation of environmental conditions is the responsibility of the customer.

Table 22. Particulate contamination specifications

Particulate contamination Specifications

Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.

NOTE: This condition applies only to data center environments. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.

NOTE: Air entering the data center must have MERV11 or MERV13 filtration.

22 Technical specifications

Particulate contamination Specifications

Conductive dust Air must be free of conductive dust, zinc whiskers, or other conductive particles.

NOTE: This condition applies to data center and non- data center environments.

Corrosive dust Air must be free of corrosive dust. Residual dust present in the air must have a deliquescent point

less than 60% relative humidity.

NOTE: This condition applies to data center and non- data center environments.

Table 23. Gaseous contamination specifications

Gaseous contamination Specifications

Copper coupon corrosion rate <300 /month per Class G1 as defined by ANSI/ISA71.04-1985.

Silver coupon corrosion rate <200 /month as defined by AHSRAE TC9.9.

NOTE: Maximum corrosive contaminant levels measured at 50% relative humidity.

Technical specifications 23

Initial system setup and configuration

Setting up your system Complete the following steps to set up your system:

Steps

1. Unpack the system.

2. Install the system into the rack. For more information about installing the system into the rack, see your system Rack Installation Placemat at Dell.com/dssmanuals.

3. Connect the peripherals to the system.

4. Connect the system to its electrical outlet.

5. Turn the system on by pressing the power button.

6. Turn on the attached peripherals.

Options to set up BMC IP address You must configure the initial network settings based on your network infrastructure to enable the communication to and from BMC. You can set up the IP address by using one of the following interfaces:

Interfaces Document/Section

iDRAC Settings utility

See Dell Integrated Dell Remote Access Controller User's Guide at Dell.com/idracmanuals

Dell Deployment Toolkit

See Dell Deployment Toolkit Users Guide at Dell.com/openmanagemanuals

Remote Access Controller Admin (RACADM)

See RACADM Command Line Interface Reference Guide and Integrated Dell Remote Access Controller User's Guide at Dell.com/idracmanuals

Remote Services that include Web Services Management (WS-Man)

See Dell Integrated Dell Remote Access Controller User's Guide at Dell.com/idracmanuals

You must use the default BMC IP address 192.168.0.120 to configure the initial network settings, including setting up DHCP or a static IP for BMC.

NOTE: To access BMC, ensure that you install the remote management port card or connect the network cable to the

Ethernet connector 1 on the system board.

NOTE: Ensure that you change the default user name and password after setting up the BMC IP address.

Log in to BMC You can log in to BMC as:

BMC local user Microsoft Active Directory user Lightweight Directory Access Protocol (LDAP) user

The default user name and password are root and calvin. You can also log in by using Single Sign-On or Smart Card.

4

24 Initial system setup and configuration

NOTE: You must have BMC local credentials to log in to BMC local.

For more information about logging in to iDRAC and iDRAC licenses, see the Integrated Dell Remote Access Controller User's Guide at Dell.com/idracmanuals.

You can also access iDRAC by using RACADM. For more information, see the RACADM Command Line Interface Reference Guide and the Integrated Dell Remote Access Controller User's Guide available at Dell.com/idracmanuals.

Options to install the operating system If the system is shipped without an operating system, install the supported operating system by using one of the following resources:

Table 24. Resources to install the operating system

Resources Location

Dell Systems Management Tools and Documentation media Dell.com/operatingsystemmanuals

Dell certified VMware ESXi Dell.com/virtualizationsolutions

Supported operating systems on Dell DSS systems Dell.com/ossupport

Methods to download firmware and drivers You can download the firmware and drivers by using any of the following methods:

Table 25. Firmware and drivers

Methods Location

From the Dell Support site Dell.com/support/home

Using BMC Dell.com/idracmanuals

Downloading the drivers and firmware Dell recommends that you download and install the latest BIOS, drivers, and systems management firmware on your system.

Prerequisites

Ensure that you clear the web browser cache before downloading the drivers and firmware.

Steps

1. Go to Dell.com/support/drivers.

2. Under the Drivers & Downloads section, type the Service Tag of your system in the Service Tag or Express Service Code box.

NOTE: If you do not have the Service Tag, select Detect My Product to allow the system to automatically detect your

Service Tag, or under General support, navigate to your product.

3. Click Drivers & Downloads. The drivers that are applicable to your selection are displayed.

4. Download the drivers you need to a USB drive, CD, or DVD.

Initial system setup and configuration 25

Pre-operating system management applications

Options to manage the pre-operating system applications Your system has the following options to manage the pre-operating system applications:

System Setup Boot Manager Preboot Execution Environment (PXE)

Related concepts

System Setup

Boot Manager

PXE boot

System Setup By using the System Setup screen, you can configure the BIOS settings, BMCsettings, and device settings of your system.

NOTE: Help text for the selected field is displayed in the graphical browser by default. To view the help text in the text

browser, press F1.

You can access system setup by using two methods:

Standard graphical browser The browser is enabled by default. Text browser The browser is enabled by using Console Redirection.

Related tasks

Viewing System Setup

Related reference

System Setup details

Viewing System Setup To view the System Setup screen, perform the following steps:

Steps

1. Turn on, or restart your system.

2. Press F2 immediately after you see the following message:

F2 = System Setup

NOTE: If your operating system begins to load before you press F2, wait for the system to finish booting, and then

restart your system and try again.

5

26 Pre-operating system management applications

Related reference

System Setup

System Setup details

System BIOS

iDRAC Settings utility

Device Settings

System Setup details The System Setup Main Menu screen details are explained as follows:

Option Description

System BIOS Enables you to configure BIOS settings.

iDRAC Settings Enables you to configure BMC settings.

The iDRAC settings utility is an interface to set up and configure the BMC parameters by using UEFI. You can enable or disable various BMC parameters by using the iDRAC settings utility. For more information about this utility, see Integrated Dell Remote Access Controller 8 Users Guide at Dell.com/idracmanuals.

Device Settings Enables you to configure device settings.

Related tasks

Viewing System Setup

Related reference

System Setup

iDRAC Settings utility

Device Settings

System BIOS You can use the System BIOS screen to edit specific functions such as boot order, system password, setup password, set the RAID mode, and enable or disable USB ports.

Related tasks

Viewing System BIOS

Related reference

System BIOS Settings details

Boot Settings

Network Settings

System Information

Memory Settings

Processor Settings

SATA Settings

Integrated Devices

Serial Communication

System Profile Settings

Miscellaneous Settings

iDRAC Settings utility

Device Settings

System Security

Pre-operating system management applications 27

Viewing System BIOS To view the System BIOS screen, perform the following steps:

Steps

1. Turn on, or restart your system.

2. Press F2 immediately after you see the following message:

F2 = System Setup

NOTE: If your operating system begins to load before you press F2, wait for the system to finish booting, and then

restart your system and try again.

3. On the System Setup Main Menu screen, click System BIOS.

Related reference

System BIOS

System BIOS Settings details

System BIOS Settings details

About this task

The System BIOS Settings screen details are explained as follows:

Option Description

System Information

Specifies information about the system such as the system model name, BIOS version, and Service Tag.

Memory Settings Specifies information and options related to the installed memory.

Processor Settings

Specifies information and options related to the processor such as speed and cache size.

SATA Settings Specifies options to enable or disable the integrated SATA controller and ports.

Boot Settings Specifies options to specify the boot mode (BIOS or UEFI). Enables you to modify UEFI and BIOS boot settings.

Network Settings Specifies options to change the network settings.

Integrated Devices Specifies options to manage integrated device controllers and ports and specify related features and options.

Serial Communication

Specifies options to manage the serial ports and specify related features and options.

System Profile Settings

Specifies options to change the processor power management settings, memory frequency, and so on.

System Security Specifies options to configure the system security settings, such as system password, setup password, Trusted Platform Module (TPM) security. It also manages the power and NMI buttons on the system.

Miscellaneous Settings

Specifies options to change the system date, time, and so on.

Related tasks

Viewing System BIOS

Related reference

System BIOS

28 Pre-operating system management applications

Boot Settings You can use the Boot Settings screen to set the boot mode to either BIOS or UEFI. It also enables you to specify the boot order.

Related tasks

Viewing Boot Settings

Choosing the system boot mode

Changing the boot order

Related reference

Boot Settings details

System BIOS

Viewing Boot Settings To view the Boot Settings screen, perform the following steps:

Steps

1. Turn on, or restart your system.

2. Press F2 immediately after you see the following message:

F2 = System Setup

NOTE: If your operating system begins to load before you press F2, wait for the system to finish booting, and then

restart your system and try again.

3. On the System Setup Main Menu screen, click System BIOS.

4. On the System BIOS screen, click Boot Settings.

Related tasks

Choosing the system boot mode

Changing the boot order

Related reference

Boot Settings

Boot Settings details

Boot Settings details

About this task

The Boot Settings screen details are explained as follows:

Option Description

Boot Mode Enables you to set the boot mode of the system. CAUTION: Switching the boot mode may prevent the system from booting if the operating system

is not installed in the same boot mode.

If the operating system supports UEFI, you can set this option to UEFI. Setting this field to BIOS allows compatibility with non-UEFI operating systems. This option is set to BIOS by default.

NOTE: Setting this field to UEFI disables the BIOS Boot Settings menu. Setting this field to BIOS

disables the UEFI Boot Settings menu.

Boot Sequence Retry

Enables or disables the Boot Sequence Retry feature. If this option is set to Enabled and the system fails to boot, the system reattempts the boot sequence after 30 seconds. This option is set to Enabled by default.

Hard-Disk Failover Specifies the hard drive that is booted in the event of a hard drive failure. The devices are selected in the Hard- Disk Drive Sequence on the Boot Option Setting menu. When this option is set to Disabled, only the first

Pre-operating system management applications 29

Option Description

hard drive in the list is attempted to boot. When this option is set to Enabled, all hard drives are attempted to boot in the order selected in the Hard-Disk Drive Sequence. This option is not enabled for UEFI Boot Mode.

Boot Option Settings

Configures the boot sequence and the boot devices.

BIOS Boot Settings

Enables or disables BIOS boot options.

NOTE: This option is enabled only if the boot mode is BIOS.

UEFI Boot Settings

Enables or disables UEFI Boot options. The Boot options include IPv4 PXE and IPv6 PXE. This option is set to IPv4 by default.

NOTE: This option is enabled only if the boot mode is UEFI.

Related tasks

Viewing Boot Settings

Choosing the system boot mode

Changing the boot order

Related reference

Boot Settings

Choosing the system boot mode

System Setup enables you to specify one of the following boot modes for installing your operating system:

BIOS boot mode (the default) is the standard BIOS-level boot interface. Unified Extensible Firmware Interface (UEFI) boot mode is an enhanced 64-bit boot interface. If you have configured your system to

boot to UEFI mode, it replaces the system BIOS.

1. From the System Setup Main Menu, click Boot Settings, and select Boot Mode. 2. Select the boot mode you want the system to boot into.

CAUTION: Switching the boot mode may prevent the system from booting if the operating system is not installed in

the same boot mode.

3. After the system boots in the specified boot mode, proceed to install your operating system from that mode.

NOTE: Operating systems must be UEFI-compatible to be installed from the UEFI boot mode. DOS and 32-bit operating

systems do not support UEFI and can only be installed from the BIOS boot mode.

NOTE: For the latest information about supported operating systems, go to Dell.com/ossupport.

Related tasks

Viewing Boot Settings

Related reference

Boot Settings

Boot Settings details

Changing the boot order You may have to change the boot order if you want to boot from a USB key or an optical drive. The following instructions may vary if you have selected BIOS for Boot Mode.

Steps

1. On the System Setup Main Menu screen, click System BIOS > Boot Settings.

2. Click Boot Option Settings > Boot Sequence.

3. Use the arrow keys to select a boot device, and use the plus (+) and minus (-) sign keys to move the device down or up in the order.

4. Click Exit, and then click Yes to save the settings on exit.

30 Pre-operating system management applications

Related tasks

Viewing Boot Settings

Related reference

Boot Settings

Boot Settings details

Network Settings You can use the Network Settings screen to modify PXE device settings. The network settings option is available only in the UEFI mode.

NOTE: The BIOS does not control network settings in the BIOS mode. For the BIOS boot mode, the optional Boot ROM

of the network controllers handles the network settings.

Related concepts

UEFI iSCSI Settings

Related tasks

Viewing Network Settings

Viewing UEFI iSCSI Settings

Related reference

Network Settings screen details

UEFI iSCSI Settings details

System BIOS

Viewing Network Settings To view the Network Settings screen, perform the following steps:

Steps

1. Turn on, or restart your system.

2. Press F2 immediately after you see the following message:

F2 = System Setup

NOTE: If your operating system begins to load before you press F2, wait for the system to finish booting, and then

restart your system and try again.

3. On the System Setup Main Menu screen, click System BIOS.

4. On the System BIOS screen, click Network Settings.

Related reference

Network Settings

Network Settings screen details

Network Settings screen details The Network Settings screen details are explained as follows:

About this task

Option Description

PXE Device n (n = 1 to 4)

Enables or disables the device. When enabled, a UEFI boot option is created for the device.

Pre-operating system management applications 31

Option Description

PXE Device n Settings(n = 1 to 4)

Enables you to control the configuration of the PXE device.

Related tasks

Viewing Network Settings

Related reference

Network Settings

UEFI iSCSI Settings You can use the iSCSI Settings screen to modify iSCSI device settings. The iSCSI Settings option is available only in the UEFI boot mode. BIOS does not control network settings in the BIOS boot mode. For the BIOS boot mode, the option ROM of the network controller handles the network settings.

Related tasks

Viewing UEFI iSCSI Settings

Related reference

UEFI iSCSI Settings details

Viewing UEFI iSCSI Settings To view the UEFI iSCSI Settings screen, perform the following steps:

Steps

1. Turn on, or restart your system.

2. Press F2 immediately after you see the following message:

F2 = System Setup

NOTE: If your operating system begins to load before you press F2, wait for the system to finish booting, and then

restart your system and try again.

3. On the System Setup Main Menu screen, click System BIOS.

4. On the System BIOS screen, click Network Settings.

5. On the Network Settings screen, click UEFI iSCSI Settings.

Related reference

UEFI iSCSI Settings

UEFI iSCSI Settings details The UEFI ISCSI Settings screen details are explained as follows:

Option Description

ISCSI Initiator Name

Specifies the name of the iSCSI initiator (iqn format).

ISCSI Device n (n = 1 to 4)

Enables or disables the iSCSI device. When disabled, a UEFI boot option is created for the iSCSI device automatically.

32 Pre-operating system management applications

System Security You can use the System Security screen to perform specific functions such as setting the system password, setup password and disabling the power button.

Related tasks

Viewing System Security

Creating a system and setup password

Using your system password to secure your system

Deleting or changing system and setup password

Related reference

System Security Settings details

Operating with a setup password enabled

System BIOS

Viewing System Security To view the System Security screen, perform the following steps:

Steps

1. Turn on, or restart your system.

2. Press F2 immediately after you see the following message:

F2 = System Setup

NOTE: If your operating system begins to load before you press F2, wait for the system to finish booting, and then

restart your system and try again.

3. On the System Setup Main Menu screen, click System BIOS.

4. On the System BIOS screen, click System Security.

Related reference

System Security

System Security Settings details

System Security Settings details

About this task

The System Security Settings screen details are explained as follows:

Option Description

Intel AES-NI Improves the speed of applications by performing encryption and decryption by using the Advanced Encryption Standard Instruction Set (AES-NI). This option is set to Enabled by default.

System Password Sets the system password. This option is set to Enabled by default and is read-only if the password jumper is not installed in the system.

Setup Password Sets the setup password. This option is read-only if the password jumper is not installed in the system.

Password Status Locks the system password. This option is set to Unlocked by default.

TPM Security NOTE: The TPM menu is available only when the TPM module is installed.

Enables you to control the reporting mode of the TPM. The TPM Security option is set to Off by default. You can only modify the TPM Status, TPM Activation, and Intel TXT fields if the TPM Status field is set to either On with Pre-boot Measurements or On without Pre-boot Measurements.

TPM Information Changes the operational state of the TPM. This option is set to No Change by default.

TPM Status Specifies the TPM status.

Pre-operating system management applications 33

Option Description

TPM Command CAUTION: Clearing the TPM results in the loss of all keys in the TPM. The loss of TPM keys may

affect booting to the operating system.

Clears all the contents of the TPM. The TPM Clear option is set to No by default.

Intel TXT Enables or disables the Intel Trusted Execution Technology (TXT) option. To enable the Intel TXT option, virtualization technology and TPM Security must be enabled with Pre-boot measurements. This option is set to Off by default.

Power Button Enables or disables the power button on the front of the system. This option is set to Enabled by default.

NMI Button Enables or disables the NMI button on the front of the system. This option is set to Disabled by default.

AC Power Recovery

Sets how the system behaves after AC power is restored to the system. This option is set to Last by default.

AC Power Recovery Delay

Sets the time delay for the system to power up after AC power is restored to the system. This option is set to Immediate by default.

User Defined Delay (60s to 240s)

Sets the User Defined Delay option when the User Defined option for AC Power Recovery Delay is selected.

UEFI Variable Access

Provides varying degrees of securing UEFI variables. When set to Standard (the default), UEFI variables are accessible in the operating system per the UEFI specification. When set to Controlled, selected UEFI variables are protected in the environment and new UEFI boot entries are forced to be at the end of the current boot order.

Secure Boot Enables Secure Boot, where the BIOS authenticates each pre-boot image by using the certificates in the Secure Boot Policy. Secure Boot is disabled by default.

Secure Boot Policy

When Secure Boot policy is set to Standard, the BIOS uses the system manufacturers key and certificates to authenticate pre-boot images. When Secure Boot policy is set to Custom, the BIOS uses the user-defined key and certificates. Secure Boot policy is set to Standard by default.

Secure Boot Policy Summary

Specifies the list of certificates and hashes that secure boot uses to authenticate images.

Related tasks

Viewing System Security

Related reference

System Security

Secure Boot Custom Policy Settings Secure Boot Custom Policy Settings is displayed only when Secure Boot Policy is set to Custom. Viewing Secure Boot Custom Policy Settings To view the Secure Boot Custom Policy Settings screen, perform the following steps:

Steps

1. Turn on, or restart your system.

2. Press F2 immediately after you see the following message:

F2 = System Setup

NOTE: If your operating system begins to load before you press F2, wait for the system to finish booting, and then

restart your system and try again.

3. On the System Setup Main Menu screen, click System BIOS.

4. On the System BIOS screen, click System Security.

5. On the System Security screen, click Secure Boot Custom Policy Settings.

34 Pre-operating system management applications

Secure Boot Custom Policy Settings details The Secure Boot Custom Policy Settings screen details are explained as follows:

Option Description

Platform Key Imports, exports, deletes, or restores the platform key (PK).

Key Exchange Key Database

Enables you to import, export, delete, or restore entries in the Key Exchange Key (KEK) Database.

Authorized Signature Database

Imports, exports, deletes, or restores entries in the Authorized Signature Database (db).

Forbidden Signature Database

Imports, exports, deletes, or restores entries in the Forbidden Signature Database (dbx).

Creating a system and setup password

Prerequisites

Ensure that the password jumper is enabled. The password jumper enables or disables the system password and setup password features. For more information, see the System board jumper settings section.

NOTE: If the password jumper setting is disabled, the existing system password and setup password are deleted and

you need not provide the system password to boot the system.

Steps

1. To enter System Setup, press F2 immediately after turning on or rebooting your system.

2. On the System Setup Main Menu screen, click System BIOS > System Security.

3. On the System Security screen, verify that Password Status is set to Unlocked.

4. In the System Password field, type your system password, and press Enter or Tab.

Use the following guidelines to assign the system password:

A password can have up to 32 characters. The password can contain the numbers 0 through 9. Only the following special characters are allowed: space, (), (+), (,), (-), (.), (/), (;), ([), (\), (]), (`).

A message prompts you to reenter the system password.

5. Reenter the system password, and click OK.

6. In the Setup Password field, type your setup password and press Enter or Tab. A message prompts you to reenter the setup password.

7. Reenter the setup password, and click OK.

8. Press Esc to return to the System BIOS screen. Press Esc again.

A message prompts you to save the changes.

NOTE: Password protection does not take effect until the system reboots.

Related reference

System board jumper settings

System board connectors and jumpers

System Security

Using your system password to secure your system If you have assigned a setup password, the system accepts your setup password as an alternate system password.

Steps

1. Turn on or reboot your system.

2. Type the system password and press Enter.

Pre-operating system management applications 35

Next steps

When Password Status is set to Locked, type the system password and press Enter when prompted at reboot.

NOTE: If an incorrect system password is typed, the system displays a message and prompts you to reenter your

password. You have three attempts to type the correct password. After the third unsuccessful attempt, the system

displays an error message that the system has stopped functioning and must be turned off. Even after you turn off and

restart the system, the error message is displayed until the correct password is entered.

Related reference

System Security

Deleting or changing system and setup password

Prerequisites

NOTE: You cannot delete or change an existing system or setup password if the Password Status is set to Locked.

Steps

1. To enter System Setup, press F2 immediately after turning on or restarting your system.

2. On the System Setup Main Menu screen, click System BIOS > System Security.

3. On the System Security screen, ensure that Password Status is set to Unlocked.

4. In the System Password field, alter or delete the existing system password, and then press Enter or Tab.

5. In the Setup Password field, alter or delete the existing setup password, and then press Enter or Tab.

If you change the system and setup password, a message prompts you to reenter the new password. If you delete the system and setup password, a message prompts you to confirm the deletion.

6. Press Esc to return to the System BIOS screen. Press Esc again, and a message prompts you to save the changes.

7. Select Setup Password, change or delete the existing setup password and press Enter or Tab.

NOTE: If you change the system password or setup password, a message prompts you to reenter the new password.

If you delete the system password or setup password, a message prompts you to confirm the deletion.

Related reference

System Security

Operating with a setup password enabled

If Setup Password is set to Enabled, type the correct setup password before modifying the system setup options.

If you do not type the correct password in three attempts, the system displays the following message:

Invalid Password! Number of unsuccessful password attempts: System Halted! Must power down.

Even after you turn off and restart the system, the error message is displayed until the correct password is typed. The following options are exceptions:

If System Password is not set to Enabled and is not locked through the Password Status option, you can assign a system password. For more information, see the System Security Settings screen section.

You cannot disable or change an existing system password.

NOTE: You can use the password status option with the setup password option to protect the system password from

unauthorized changes.

Related tasks

Viewing System Security

Related reference

System Security

36 Pre-operating system management applications

System Information You can use the System Information screen to view system properties such as Service Tag, system model name, and the BIOS version.

Related tasks

Viewing System Information

Related reference

System Information details

System BIOS

Viewing System Information To view the System Information screen, perform the following steps:

Steps

1. Turn on, or restart your system.

2. Press F2 immediately after you see the following message:

F2 = System Setup

NOTE: If your operating system begins to load before you press F2, wait for the system to finish booting, and then

restart your system and try again.

3. On the System Setup Main Menu screen, click System BIOS.

4. On the System BIOS screen, click System Information.

Related reference

System Information

System Information details

About this task

The System Information screen details are explained as follows:

Option Description

System Model Name

Specifies the system model name.

System BIOS Version

Specifies the BIOS version installed on the system.

System Management Engine Version

Specifies the current version of the Management Engine firmware.

System Service Tag

Specifies the system Service Tag.

System Manufacturer

Specifies the name of the system manufacturer.

System Manufacturer Contact Information

Specifies the contact information of the system manufacturer.

System CPLD Version

Specifies the current version of the system complex programmable logic device (CPLD) firmware.

UEFI Compliance Version

Specifies the UEFI compliance level of the system firmware.

Pre-operating system management applications 37

Related tasks

Viewing System Information

Related reference

System Information

System Information details

Memory Settings You can use the Memory Settings screen to view all the memory settings and enable or disable specific memory functions, such as system memory testing and node interleaving.

Related tasks

Viewing Memory Settings

Related reference

Memory Settings details

System BIOS

Viewing Memory Settings To view the Memory Settings screen, perform the following steps:

Steps

1. Turn on, or restart your system.

2. Press F2 immediately after you see the following message:

F2 = System Setup

NOTE: If your operating system begins to load before you press F2, wait for the system to finish booting, and then

restart your system and try again.

3. On the System Setup Main Menu screen, click System BIOS.

4. On the System BIOS screen, click Memory Settings.

Related reference

Memory Settings

Memory Settings details

Memory Settings details

About this task

The Memory Settings screen details are explained as follows:

Option Description

System Memory Size

Specifies the memory size in the system.

System Memory Type

Specifies the type of memory installed in the system.

System Memory Speed

Specifies the system memory speed.

System Memory Voltage

Specifies the system memory voltage.

Video Memory Specifies the amount of video memory.

38 Pre-operating system management applications

Option Description

System Memory Testing

Specifies whether the system memory tests are run during system boot. Options are Enabled and Disabled. This option is set to Disabled by default.

Memory Operating Mode

Specifies the memory operating mode. The options available are Optimizer Mode, Advanced ECC Mode, Mirror Mode, Spare Mode, Spare with Advanced ECC Mode. This option is set to Optimizer Mode by default.

NOTE: The Memory Operating Mode option can have different default and available options based

on the memory configuration of your system.

Node Interleaving Specifies if Non-Uniform Memory architecture (NUMA) is supported. If this field is set to Enabled, memory interleaving is supported if a symmetric memory configuration is installed. If the field is set to Disabled, the system supports NUMA (asymmetric) memory configurations. This option is set to Disabled by default.

Snoop Mode Specifies the Snoop Mode options. The Snoop Mode options available are Home Snoop, Early Snoop, and Cluster on Die. This option is set to Early Snoop by default. This field is available only when the Node Interleaving is set to Disabled.

Related tasks

Viewing Memory Settings

Related reference

Memory Settings

Processor Settings You can use the Processor Settings screen to view the processor settings, and perform specific functions such as enabling virtualization technology, hardware prefetcher, and logical processor idling.

Related tasks

Viewing Processor Settings

Related reference

Processor Settings details

System BIOS

Viewing Processor Settings To view the Processor Settings screen, perform the following steps:

Steps

1. Turn on, or restart your system.

2. Press F2 immediately after you see the following message:

F2 = System Setup

NOTE: If your operating system begins to load before you press F2, wait for the system to finish booting, and then

restart your system and try again.

3. On the System Setup Main Menu screen, click System BIOS.

4. On the System BIOS screen, click Processor Settings.

Related reference

Processor Settings

Processor Settings details

Pre-operating system management applications 39

Processor Settings details

About this task

The Processor Settings screen details are explained as follows:

Option Description

Logical Processor Enables or disables the logical processors and displays the number of logical processors. If this option is set to Enabled, the BIOS displays all the logical processors. If this option is set to Disabled, the BIOS displays only one logical processor per core. This option is set to Enabled by default.

Alternate RTID (Requestor Transaction ID) Setting

Modifies Requestor Transaction IDs, which are QPI resources. This option is set to Disabled by default.

NOTE: Enabling this option may negatively impact the overall system performance.

Virtualization Technology

Enables or disables the additional hardware capabilities provided for virtualization. This option is set to Enabled by default.

Address Translation Service (ATS)

Defines the Address Translation Cache (ATC) for devices to cache the DMA transactions. This option provides an interface between CPU and DMA Memory Management to a chipset's Address Translation and Protection Table to translate DMA addresses to host addresses. This option is set to Enabled by default.

Adjacent Cache Line Prefetch

Optimizes the system for applications that need high utilization of sequential memory access. This option is set to Enabled by default. You can disable this option for applications that need high utilization of random memory access.

Hardware Prefetcher

Enables or disables the hardware prefetcher. This option is set to Enabled by default.

DCU Streamer Prefetcher

Enables or disables the Data Cache Unit (DCU) streamer prefetcher. This option is set to Enabled by default.

DCU IP Prefetcher Enables or disables the Data Cache Unit (DCU) IP prefetcher. This option is set to Enabled by default.

Logical Processor Idling

Enables you to improve the energy efficiency of a system. It uses the operating system core parking algorithm and parks some of the logical processors in the system which in turn allows the corresponding processor cores to transition into a lower power idle state. This option can only be enabled if the operating system supports it. It is set to Disabled by default.

Configurable TDP Enables you to reconfigure the processor Thermal Design Power (TDP) levels during POST based on the power and thermal delivery capabilities of the system. TDP verifies the maximum heat the cooling system is needed to dissipate. This option is set to Nominal by default.

NOTE: This option is only available on certain stock keeping units (SKUs) of the processors.

X2Apic Mode Enables or disables the X2Apic mode.

Number of Cores per Processor

Controls the number of enabled cores in each processor. This option is set to All by default.

Processor 64-bit Support

Specifies if the processor(s) support 64-bit extensions.

Processor Core Speed

Specifies the maximum core frequency of the processor.

Process Bus Speed

Displays the bus speed of the processor.

NOTE: The processor bus speed option displays only when both processors are installed.

Processor 1 NOTE: Depending on the number of CPUs, there may be up to four processors listed.

The following settings are displayed for each processor installed in the system:

Option Description

Family-Model- Stepping

Specifies the family, model, and stepping of the processor as defined by Intel.

Brand Specifies the brand name.

40 Pre-operating system management applications

Option Description

Option Description

Level 2 Cache Specifies the total L2 cache.

Level 3 Cache Specifies the total L3 cache.

Number of Cores Specifies the number of cores per processor.

Related tasks

Viewing Processor Settings

Related reference

Processor Settings

SATA Settings You can use the SATA Settings screen to view the SATA settings of SATA devices and enable RAID on your system.

Related tasks

Viewing SATA Settings

Related reference

SATA Settings details

System BIOS

Viewing SATA Settings To view the SATA Settings screen, perform the following steps:

Steps

1. Turn on, or restart your system.

2. Press F2 immediately after you see the following message:

F2 = System Setup

NOTE: If your operating system begins to load before you press F2, wait for the system to finish booting, and then

restart your system and try again.

3. On the System Setup Main Menu screen, click System BIOS.

4. On the System BIOS screen, click SATA Settings.

Related reference

SATA Settings

SATA Settings details

SATA Settings details

About this task

The SATA Settings screen details are explained as follows:

Option Description

Embedded SATA Enables the embedded SATA option to be set to Off, ATA, AHCI, or RAID modes. This option is set to AHCI by default.

Pre-operating system management applications 41

Option Description

Security Freeze Lock

Sends Security Freeze Lock command to the Embedded SATA drives during POST. This option is applicable only for ATA and AHCI modes.

Write Cache Enables or disables the command for Embedded SATA drives during POST.

Port A Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support.

For AHCI or RAID mode, BIOS support is always enabled.

Option Description

Model Specifies the drive model of the selected device.

Drive Type Specifies the type of drive attached to the SATA port.

Capacity Specifies the total capacity of the hard drive. This field is undefined for removable media devices such as optical drives.

Port B Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support.

For AHCI or RAID mode, BIOS support is always enabled.

Option Description

Model Specifies the drive model of the selected device.

Drive Type Specifies the type of drive attached to the SATA port.

Capacity Specifies the total capacity of the hard drive. This field is undefined for removable media devices such as optical drives.

Related tasks

Viewing SATA Settings

Related reference

SATA Settings

Integrated Devices You can use the Integrated Devices screen to view and configure the settings of all integrated devices including the video controller, integrated RAID controller, and the USB ports.

Related tasks

Viewing Integrated Devices

Related reference

Integrated Devices details

System BIOS

Viewing Integrated Devices To view the Integrated Devices screen, perform the following steps:

Steps

1. Turn on, or restart your system.

2. Press F2 immediately after you see the following message:

F2 = System Setup

42 Pre-operating system management applications

NOTE: If your operating system begins to load before you press F2, wait for the system to finish booting, and then

restart your system and try again.

3. On the System Setup Main Menu screen, click System BIOS.

4. On the System BIOS screen, click Integrated Devices.

Related reference

Integrated Devices

Integrated Devices details

Integrated Devices details

About this task

The Integrated Devices screen details are explained as follows:

Option Description

USB 3.0 Setting Enables or disables the USB 3.0 support. Enable this option only if your operating system supports USB 3.0. If you disable this option, devices operate at USB 2.0 speed. USB 3.0 is enabled by default.

User Accessible USB Ports

Enables or disables the USB ports. Selecting Only Back Ports On disables the front USB ports, selecting All Ports Off disables all USB ports. The USB keyboard and mouse operate during boot process in certain operating systems. After the boot process is complete, the USB keyboard and mouse do not work if the ports are disabled.

NOTE: Selecting Only Back Ports On and All Ports Off disables the USB management port and also

restricts access to iDRAC features.

I/OAT DMA Engine

Enables or disables the I/OAT option. Enable only if the hardware and software support the feature.

Embedded Video Controller

Enables or disables the Embedded Video Controller option. This option is set to Enabled by default.

Current State of Embedded Video Controller

Displays the current state of the embedded video controller. The Current State of Embedded Video Controller option is a read-only field. If the Embedded Video Controller is the only display capability in the system (that is, no add-in graphics card is installed), then the Embedded Video Controller is automatically used as the primary display even if the Embedded Video Controller setting is set to Disabled.

SR-IOV Global Enable

Enables or disables the BIOS configuration of Single Root I/O Virtualization (SR-IOV) devices. This option is set to Disabled by default.

OS Watchdog Timer

If your system stops responding, this watchdog timer aids in the recovery of your operating system. When this option is set to Enabled, the operating system initializes the timer. When this option is set to Disabled (the default), the timer does not have any effect on the system.

Memory Mapped I/O above 4 GB

Enables or disables the support for PCIe devices that need large amounts of memory. This option is set to Enabled by default.

Slot Disablement Enables or disables the available PCIe slots on your system. The slot disablement feature controls the configuration of PCIe cards installed in the specified slot. Slots must be disabled only when the installed peripheral card prevents booting into the operating system or causes delays in system startup. If the slot is disabled, both the Option ROM and UEFI drivers are disabled.

Related tasks

Viewing Integrated Devices

Related reference

Integrated Devices

Pre-operating system management applications 43

Serial Communication You can use the Serial Communication screen to view the properties of the serial communication port.

Related tasks

Viewing Serial Communication

Related reference

Serial Communication details

System BIOS

Viewing Serial Communication To view the Serial Communication screen, perform the following steps:

Steps

1. Turn on, or restart your system.

2. Press F2 immediately after you see the following message:

F2 = System Setup

NOTE: If your operating system begins to load before you press F2, wait for the system to finish booting, and then

restart your system and try again.

3. On the System Setup Main Menu screen, click System BIOS.

4. On the System BIOS screen, click Serial Communication.

Related reference

Serial Communication

Serial Communication details

Serial Communication details

About this task

The Serial Communication screen details are explained as follows:

Option Description

Serial Communication

Selects serial communication devices (Serial Device 1 and Serial Device 2) in BIOS. BIOS console redirection can also be enabled and the port address can be specified. This option is set to Auto by default.

Serial Port Address

Enables you to set the port address for serial devices. This option is set to Serial Device 1=COM2, Serial Device 2=COM1 by default.

NOTE: You can use only Serial Device 2 for the Serial Over LAN (SOL) feature. To use console

redirection by SOL, configure the same port address for console redirection and the serial device.

NOTE: Every time the system boots, the BIOS syncs the serial MUX setting saved in iDRAC. The

serial MUX setting can independently be changed in iDRAC. Loading the BIOS default settings

from within the BIOS setup utility may not always revert the serial MUX setting to the default

setting of Serial Device 1.

External Serial Connector

Enables you to associate the External Serial Connector to Serial Device 1, Serial Device 2, or the Remote Access Device by using this option.

NOTE: Only Serial Device 2 can be used for Serial Over LAN (SOL). To use console redirection by

SOL, configure the same port address for console redirection and the serial device.

NOTE: Every time the system boots, the BIOS syncs the serial MUX setting saved in iDRAC. The

serial MUX setting can independently be changed in iDRAC. Loading the BIOS default settings

44 Pre-operating system management applications

Option Description

from within the BIOS setup utility may not always revert this setting to the default setting of

Serial Device 1.

Failsafe Baud Rate Specifies the failsafe baud rate for console redirection. The BIOS attempts to determine the baud rate automatically. This failsafe baud rate is used only if the attempt fails, and the value must not be changed. This option is set to 115200 by default.

Remote Terminal Type

Sets the remote console terminal type. This option is set to VT 100/VT 220 by default.

Redirection After Boot

Enables or disables the BIOS console redirection when the operating system is loaded. This option is set to Enabled by default.

Related tasks

Viewing Serial Communication

Related reference

Serial Communication

System Profile Settings You can use the System Profile Settings screen to enable specific system performance settings such as power management.

Viewing System Profile Settings To view the System Profile Settings screen, perform the following steps:

Steps

1. Turn on, or restart your system.

2. Press F2 immediately after you see the following message:

F2 = System Setup

NOTE: If your operating system begins to load before you press F2, wait for the system to finish booting, and then

restart your system and try again.

3. On the System Setup Main Menu screen, click System BIOS.

4. On the System BIOS screen, click System Profile Settings.

System Profile Settings details

About this task

The System Profile Settings screen details are explained as follows:

Option Description

System Profile Sets the system profile. If you set the System Profile option to a mode other than Custom, the BIOS automatically sets the rest of the options. You can only change the rest of the options if the mode is set to Custom. This option is set to Performance Per Watt Optimized (DAPC) by default. DAPC is Dell Active Power Controller.

NOTE: All the parameters on the system profile setting screen are available only when the System

Profile option is set to Custom.

CPU Power Management

Sets the CPU power management. This option is set to System DBPM (DAPC) by default. DBPM is Demand- Based Power Management.

Memory Frequency

Sets the speed of the system memory. You can select Maximum Performance, Maximum Reliability, or a specific speed.

Turbo Boost Enables or disables the processor to operate in the turbo boost mode. This option is set to Enabled by default.

Pre-operating system management applications 45

Option Description

Energy Efficient Turbo

Enables or disables the Energy Efficient Turbo option.

Energy Efficient Turbo (EET) is a mode of operation where a processors core frequency is adjusted to be within the turbo range based on workload.

C1E Enables or disables the processor to switch to a minimum performance state when it is idle. This option is set to Enabled by default.

C States Enables or disables the processor to operate in all available power states. This option is set to Enabled by default.

Collaborative CPU Performance Control

Enables or disables the CPU power management option. When set to Enabled, the CPU power management is controlled by the OS DBPM and the System DBPM (DAPC). This option is set to Disabled by default.

Memory Patrol Scrub

Sets the memory patrol scrub frequency. This option is set to Standard by default.

Memory Refresh Rate

Sets the memory refresh rate to either 1x or 2x. This option is set to 1x by default.

Uncore Frequency Enables you to select the Processor Uncore Frequency option.

Dynamic mode enables the processor to optimize power resources across the cores and uncore during runtime. The optimization of the uncore frequency to either save power or optimize performance is influenced by the setting of the Energy Efficiency Policy option.

Energy Efficient Policy

Enables you to select the Energy Efficient Policy option.

The CPU uses the setting to manipulate the internal behavior of the processor and determines whether to target higher performance or better power savings.

Number of Turbo Boot Enabled Cores for Processor 1

NOTE: If there are two processors installed in the system, you see an entry for Number of Turbo

Boost Enabled Cores for Processor 2.

Controls the number of turbo boost enabled cores for processor 1. The maximum number of cores is enabled by default.

Monitor/Mwait Enables the Monitor/Mwait instructions in the processor. This option is set to Enabled for all system profiles, except Custom by default.

NOTE: This option can be disabled only if the C States option in the Custom mode is set to

disabled.

NOTE: When C States is set to Enabled in the Custom mode, changing the Monitor/Mwait setting

does not impact the system power or performance.

Miscellaneous Settings You can use the Miscellaneous Settings screen to perform specific functions such as updating the asset tag and changing the system date and time.

Viewing Miscellaneous Settings To view the Miscellaneous Settings screen, perform the following steps:

Steps

1. Turn on, or restart your system.

2. Press F2 immediately after you see the following message:

F2 = System Setup

NOTE: If your operating system begins to load before you press F2, wait for the system to finish booting, and then

restart your system and try again.

3. On the System Setup Main Menu screen, click System BIOS.

4. On the System BIOS screen, click Miscellaneous Settings.

46 Pre-operating system management applications

Related reference

Miscellaneous Settings

Miscellaneous Settings details

Miscellaneous Settings details

About this task

The Miscellaneous Settings screen details are explained as follows:

Option Description

System Time Enables you to set the time on the system.

System Date Enables you to set the date on the system.

Asset Tag Specifies the asset tag and enables you to modify it for security and tracking purposes.

Keyboard NumLock

Enables you to set whether the system boots with the NumLock enabled or disabled. This option is set to On by default.

NOTE: This option does not apply to 84-key keyboards.

F1/F2 Prompt on Error

Enables or disables the F1/F2 prompt on error. This option is set to Enabled by default. The F1/F2 prompt also includes keyboard errors.

Load Legacy Video Option ROM

Enables you to determine whether the system BIOS loads the legacy video (INT 10H) option ROM from the video controller. Selecting Enabled in the operating system does not support UEFI video output standards. This field is available only for UEFI boot mode. You cannot set the option to Enabled if UEFI Secure Boot mode is enabled.

In-System Characterization

Enables or disables In-System Characterization. This option is set to Disabled by default. The two other options are Enabled and Enabled - No Reboot.

NOTE: The default setting for In-System Characterization is subject to change in future BIOS

releases.

When enabled, In-System Characterization (ISC) executes during POST upon detecting relevant change(s) in system configuration to optimize system power and performance. ISC takes about 20 seconds to execute, and system reset is needed for ISC results to be applied. The Enabled - No Reboot option executes ISC and continues without applying ISC results until the next time system reset occurs. The Enabled option executes ISC and forces an immediate system reset so that ISC results can be applied. It takes the system longer to be ready due to the forced system reset. When disabled, ISC does not execute.

Related tasks

Viewing Miscellaneous Settings

Related reference

Miscellaneous Settings

iDRAC Settings utility The iDRAC settings utility is an interface to set up and configure the iDRAC parameters by using UEFI. You can enable or disable various iDRAC parameters by using the iDRAC settings utility.

NOTE: Accessing some of the features on the iDRAC settings utility needs the iDRAC Enterprise License upgrade.

For more information about using iDRAC, see Dell Integrated Dell Remote Access Controller User's Guide at Dell.com/idracmanuals.

Related concepts

Device Settings

Related tasks

Entering the iDRAC Settings utility

Changing the thermal settings

Pre-operating system management applications 47

Related reference

System BIOS

Entering the iDRAC Settings utility

Steps

1. Turn on or restart the managed system.

2. Press F2 during Power-on Self-test (POST).

3. On the System Setup Main Menu page, click iDRAC Settings. The iDRAC Settings screen is displayed.

Related reference

iDRAC Settings utility

Changing the thermal settings The iDRAC settings utility enables you to select and customize the thermal control settings for your system.

1. Click iDRAC Settings > Thermal. 2. Under SYSTEM THERMAL PROFILE > Thermal Profile, select one of the following options:

Default Thermal Profile Settings Maximum Performance (Performance Optimized) Minimum Power (Performance per Watt Optimized)

3. Under USER COOLING OPTIONS, set the Fan Speed Offset, Minimum Fan Speed, and Custom Minimum Fan Speed. 4. Click Back > Finish > Yes.

Related reference

iDRAC Settings utility

Device Settings Device Settings enables you to configure device parameters.

Related reference

System BIOS

Boot Manager The Boot Manager screen enables you to select boot options and diagnostic utilities.

Related tasks

Viewing Boot Manager

Related reference

Boot Manager main menu

System BIOS

48 Pre-operating system management applications

Viewing Boot Manager To enter Boot Manager:

Steps

1. Turn on, or restart your system.

2. Press F11 when you see the following message:

F11 = Boot Manager

If your operating system begins to load before you press F11, allow the system to complete the booting, and then restart your system and try again.

Related reference

Boot Manager

Boot Manager main menu

Boot Manager main menu Menu item Description

Continue Normal Boot

The system attempts to boot to devices starting with the first item in the boot order. If the boot attempt fails, the system continues with the next item in the boot order until the boot is successful or no more boot options are found.

One-shot Boot Menu

Enables you to access boot menu, where you can select a one-time boot device to boot from.

Launch System Setup

Enables you to access System Setup.

System Utilities Enables you to launch System Utilities menu such as System Diagnostics and UEFI shell.

Related tasks

Viewing Boot Manager

Related reference

Boot Manager

One-shot BIOS boot menu One-shot BIOS boot menu enables you to select a boot device to boot from.

Related reference

Boot Manager

System Utilities System Utilities contains the following utilities that can be launched:

Launch Diagnostics BIOS Update File Explorer Reboot System

Related reference

Boot Manager

Pre-operating system management applications 49

PXE boot The Preboot Execution Environment (PXE) is an industry standard client or interface that allows networked computers that are not yet loaded with an operating system to be configured and booted remotely by an administrator.

50 Pre-operating system management applications

Installing and removing system components This section provides information about installing and removing the system components. Topics:

Safety instructions Before working inside your system After working inside your system Recommended tools System cover Inside the system Cooling shroud System memory Hard drives Cooling fans Expansion cards and expansion card riser Remote management port card (optional) Processors and heat sinks Power supply units System battery Hard drive backplane Control panel Power interposer board System board

Safety instructions NOTE: Whenever you need to lift the system, get others to assist you. To avoid injury, do not attempt to lift the system

by yourself.

WARNING: Opening or removing the system cover while the system is powered on may expose you to a risk of electric

shock.

CAUTION: Do not operate the system without the cover for a duration exceeding five minutes.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

NOTE: Dell recommends that you always use a static mat and static strap while working on components inside the

system.

NOTE: To ensure proper operation and cooling, all bays in the system and system fans must be populated always with

either a component or with a blank.

Before working inside your system Prerequisites

Follow the safety guidelines listed in the Safety instructions section.

6

Installing and removing system components 51

Steps

1. Turn off the system, including any attached peripherals.

2. Disconnect the system from the electrical outlet and disconnect the peripherals.

3. If applicable, remove the system from the rack.

4. Remove the system cover.

Related tasks

Removing the system cover

Related reference

Safety instructions

After working inside your system Prerequisites

Follow the safety guidelines listed in the Safety instructions section.

Steps

1. Install the system cover.

2. If applicable, install the system into the rack.

3. Reconnect the peripherals and connect the system to the electrical outlet.

4. Turn on the system, including any attached peripherals.

Related tasks

Installing the system cover

Related reference

Safety instructions

Recommended tools You need the following tools to perform the removal and installation procedures:

Phillips #2 screwdriver Plastic scribe Wrist grounding strap

System cover The system cover protects the components inside the system and helps in maintaining air flow inside the system.

Removing the system cover

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Turn off the system, including any attached peripherals.

52 Installing and removing system components

3. Disconnect the system from the electrical outlet and peripherals.

Steps

1. Loosen the screw that secures the system cover to the chassis.

2. Hold the cover on both sides, and lift the cover away from the system.

Figure 12. Removing the system cover

a. system cover b. screw

Related tasks

Installing the system cover

Related reference

Safety instructions

Installing the system cover

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

Follow the safety guidelines listed in the Safety instructions section.

Steps

1. Align the slots of the system cover with the tabs on the chassis and slide the cover forward.

2. Tighten the screw securing the system cover to the chassis.

Installing and removing system components 53

Figure 13. Installing the system cover

a. system cover b. screw

Related tasks

After working inside your system

Removing the system cover

Related reference

Safety instructions

54 Installing and removing system components

Inside the system

Figure 14. Inside the systemwith redundant power supply unit (PSU)

1. control panel module 2. hard drive backplane

3. cable routing latch 4. power interposer board

5. PSU (2) 6. expansion card riser

7. memory module socket (A1, A5, A2, A6) 8. processor 1

9. memory module socket (A8, A4, A7, A3) 10. cooling fan (5)

11. hard drive/SSD

Installing and removing system components 55

Figure 15. Inside the systemwith non-redundant PSU

1. control panel module 2. cable routing latch

3. PSU 4. expansion card connector (2)

5. memory module socket (A1, A5, A2, A6) 6. processor 1

7. memory module socket (A8, A4, A7, A3) 8. cooling fan (4)

9. cabled hard drive (4)

Cooling shroud The cooling shroud has aerodynamically placed openings that direct the airflow across the entire system. The airflow passes through all the critical parts of the system, where the vacuum pulls air across the entire surface area of the heat sink, thus allowing increased cooling.

Removing the cooling shroud

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

56 Installing and removing system components

CAUTION: Never operate your system with the cooling shroud removed. The system may get overheated quickly,

resulting in shutdown of the system and loss of data.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section.

Steps

Holding the touch points, lift the cooling shroud away from the system.

Figure 16. Removing the cooling shroud

a. cooling shroud b. guide on the cooling shroud c. slot on the system board

Next steps

1. Install the cooling shroud. 2. Follow the procedure listed in the After working inside your system section.

Related tasks

Before working inside your system

Removing the system cover

Installing the cooling shroud

After working inside your system

Related reference

Safety instructions

Installing the cooling shroud

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

Installing and removing system components 57

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section.

Steps

1. Align the guide on the cooling shroud with the slot on the system board.

2. Lower the cooling shroud into the chassis until it is firmly seated.

Figure 17. Installing the cooling shroud

a. cooling shroud b. guide on the cooling shroud c. slot on the system board

Next steps

Follow the procedure listed in the After working inside your system section.

Related tasks

Before working inside your system

After working inside your system

Removing the cooling shroud

Related reference

Safety instructions

System memory Your system supports DDR4 registered DIMMs (RDIMM).

NOTE: MT/s indicates DIMM speed in MegaTransfers per second.

Memory bus operating frequency can be 2400 MT/s, 2133 MT/s, or 1866 MT/s depending on:

DIMM type ( RDIMM) Number of DIMMs populated per channel System profile selected (for example, Performance Optimized, Custom, or Dense Configuration Optimized) Maximum supported DIMM frequency of the processors

58 Installing and removing system components

Your system contains 8 memory sockets split into two sets of four sockets. DIMMs in sockets A1 to A8 are assigned to processor 1. Each 4-socket set is organized into two channels. In each channel of the 4-socket set, the release levers of the first socket are marked white and those of the second socket are marked black.

Your system contains 8 memory sockets split into two sets of four sockets. DIMMs in sockets A1 to A8 are assigned to processor 1. Each 4-socket set is organized into two channels. In each channel of the 4-socket set, the release levers of the first socket are marked white and those of the second socket are marked black.

Figure 18. Memory socket locations

Memory channels are organized as follows:

Table 26. Memory channels

Processor channel 0 channel 1 channel 2 channel 3

Processor 1 slots A1 and A5 slots A2 and A6 slots A3 and A7 slots A4 and A8

The following table shows the memory populations and operating frequencies for the supported configurations.

Table 27. Memory populations and operating frequencies

DIMM Type DIMMs Populated/ Channel Voltage Operating Frequency

(in MT/s) Maximum DIMM Rank/

Channel

RDIMM 1

1.2 v 2400, 2133, and 1866 Single rank or dual rank 2

General memory module installation guidelines Your system supports Flexible Memory Configuration, enabling the system to be configured and run in any valid chipset architectural configuration. The following are the recommended guidelines for installing memory modules:

x4 and x8 DRAM based DIMMs can be mixed. For more information, see the Mode specific guidelines section. Up to two dual- or single-rank RDIMMs can be populated per channel. Populate DIMM sockets only if a processor is installed. For single-processor systems, sockets A1 to A8 are available. Populate all sockets with white release levers first, and then all the sockets with black release levers. When mixing memory modules with different capacities, populate the sockets with memory modules with highest capacity first. For

example, if you want to mix 4 GB and 8 GB DIMMs, populate 8 GB DIMMs in the sockets with white release levers and 4 GB DIMMs in the sockets with black release levers.

Memory modules of different capacities can be mixed provided other memory population rules are followed (for example, 4 GB and 8 GB memory modules can be mixed).

Mixing of more than two DIMM capacities in a system is not supported. Populate two DIMMs per processor (one DIMM per channel) at a time to maximize performance.

Installing and removing system components 59

Related reference

Mode-specific guidelines

Mode-specific guidelines Four memory channels are allocated to each processor. The allowable configurations depend on the memory mode selected.

NOTE: You can mix x4 and x8 DRAM based DIMMs to support RAS features. However, all guidelines for specific RAS

features must be followed. x4 DRAM based DIMMs retain Single Device Data Correction (SDDC) in memory optimized

(independent channel) mode. x8 DRAM based DIMMs need Advanced ECC mode to gain SDDC.

Advanced Error Correction Code (lockstep) Advanced Error Correction Code (ECC) mode extends SDDC from x4 DRAM based DIMMs to both x4 and x8 DRAMs. This protects against single DRAM chip failures during normal operation.

The installation guidelines for memory modules are as follows:

Memory modules must be identical in size, speed, and technology. DIMMs installed in memory sockets with white release levers must be identical and the same rule applies for sockets with black release

levers. This ensures that identical DIMMs are installed in matched pair for example, A1 with A2, A3 with A4, A5 with A6, and so on.

Memory optimized (independent channel) mode This mode supports Single Device Data Correction (SDDC) only for memory modules that use x4 device width. It does not impose any specific slot population requirements.

Memory sparing NOTE: To use memory sparing, this feature must be enabled in System Setup.

In this mode, one rank per channel is reserved as a spare. If persistent correctable errors are detected on a rank, the data from this rank is copied to the spare rank, and the failed rank is disabled.

With memory sparing enabled, the system memory available to the operating system is reduced by one rank per channel. For example, in a dual-processor configuration with sixteen 4 GB single-rank memory modules, the available system memory is: 3/4 (ranks/channel) 16 (memory modules) 4 GB = 48 GB, and not 16 (memory modules) 4 GB = 64 GB.

NOTE: Memory sparing does not offer protection against a multi-bit uncorrectable error.

NOTE: Both Advanced ECC/Lockstep and Optimizer modes support memory sparing.

Related reference

System Setup

Sample memory configurations The following table shows sample memory configurations for one processor configuration that follow the appropriate memory guidelines.

NOTE: 1R and 2R in the following tables indicate single- and dual-rank DIMMs respectively.

Table 28. Memory configurationssingle processor

System Capacity (in GB)

DIMM Size (in GB)

Number of DIMMs

DIMM Rank, Organization, and Frequency

DIMM Slot Population

8 8 1 1R, x8, 2400 MT/s A1

16 8 2 1R, x8, 2400 MT/s A1, A2

16 1 2R, x8, 2400 MT/s A1

60 Installing and removing system components

System Capacity (in GB)

DIMM Size (in GB)

Number of DIMMs

DIMM Rank, Organization, and Frequency

DIMM Slot Population

32 8 4 1R, x8, 2400 MT/s A1, A2, A3, A4

16 2 2R, x8, 2400 MT/s A1, A2

32 1 2R, x4, 2400 MT/s A1

48 8 6 1R, x8, 2400 MT/s A1, A2, A3, A4, A5, A6

16 3 2R, x8, 2400 MT/s A1, A2, A3

64 8 8 1R, x8, 2400 MT/s A1, A2, A3, A4, A5, A6, A7, A8

16 4 2R, x8, 2400 MT/s A1, A2, A3, A4

32 2 2R, x4, 2400 MT/s A1, A2

96 16 6 2R, x8, 2400 MT/s A1, A2, A3, A4, A5, A6

32 3 2R, x4, 2400 MT/s A1, A2, A3

128 16 8 2R, x8, 2400 MT/s A1, A2, A3, A4, A5, A6, A7, A8

32 4 2R, x4, 2400 MT/s A1, A2, A3, A4

192 32 6 2R, x4, 2400 MT/s A1, A2, A3, A4, A5, A6

256 32 8 2R, x4, 2400 MT/s A1, A2, A3, A4, A5, A6, A7, A8

Removing memory modules

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section. 3. Remove the cooling shroud.

NOTE: If open, close the expansion card latch on the cooling shroud to release the full length card.

4. If connected, disconnect the cables from expansion card(s). 5. If installed, remove the expansion card riser.

NOTE: The memory modules are hot to touch for some time after the system has been powered down. Allow the

memory modules to cool before handling them. Handle the memory modules by the card edges and avoid touching the

components or metallic contacts on the memory module.

CAUTION: To ensure proper system cooling, memory module blanks must be installed in any memory socket that is not

occupied. Remove memory module blanks only if you intend to install memory modules in those sockets.

Steps

1. Locate the appropriate memory module socket.

CAUTION: Handle each memory module only by the card edges, ensuring not to touch the middle of the memory

module or metallic contacts.

Installing and removing system components 61

2. To release the memory module from the socket, simultaneously press the ejectors on both ends of the memory module socket.

3. Lift and remove the memory module from the system.

Figure 19. Removing the memory module

a. memory module b. memory module socket c. memory module socket ejector (2)

Next steps

1. Install the memory module.

NOTE: If you are removing the memory module permanently, install a memory module blank.

2. If removed, install the PCIe expansion card riser. 3. If disconnected, reconnect the cables to the expansion card(s). 4. Install the cooling shroud. 5. If closed, open the expansion card latch on the cooling shroud to support the full length expansion card. 6. Follow the procedure listed in the After working inside your system section.

Related tasks

Before working inside your system

Removing the cooling shroud

Removing the expansion card riser

Installing memory modules

Installing the expansion card riser

Installing the cooling shroud

After working inside your system

Related reference

Safety instructions

62 Installing and removing system components

Installing memory modules

Prerequisites

NOTE: The memory modules are hot to touch for some time after the system has been powered down. Allow the

memory modules to cool before handling them. Handle the memory modules by the card edges and avoid touching the

components or metallic contacts on the memory module.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section. 3. If installed, remove the PCIe expansion card riser. 4. Remove the cooling shroud.

Steps

1. Locate the appropriate memory module socket.

CAUTION: Handle each memory module only by the card edges, ensuring not to touch the middle of the memory

module or metallic contacts.

2. Open the ejectors on the memory module socket outward to allow the memory module to be inserted into the socket.

3. Align the edge connector of the memory module with the alignment key of the memory module socket, and insert the memory module in the socket.

CAUTION: Do not apply pressure at the center of the memory module; apply pressure at both ends of the memory

module evenly.

NOTE: The memory module socket has an alignment key that enables you to install the memory module in the socket

in only one orientation.

4. Press the memory module with your thumbs until the socket levers firmly click into place.

When the memory module is properly seated in the socket, the levers on the memory module socket align with the levers on the other sockets that have memory modules installed.

Figure 20. Installing the memory module

a. memory module b. alignment key

Installing and removing system components 63

c. memory module socket ejector (2)

Next steps

1. If removed, reinstall the PCIe expansion card riser. 2. Install the cooling shroud. 3. Follow the procedure listed in the After working inside your system section. 4. Press F2 to enter System Setup, and check the System Memory setting.

The system should have already changed the value to reflect the installed memory. 5. If the value is incorrect, one or more of the memory modules may not be installed properly. Ensure that the memory module is firmly

seated in the memory module socket. 6. Run the system memory test in system diagnostics.

Related tasks

Before working inside your system

Removing the expansion card riser

Removing the cooling shroud

Installing the expansion card riser

Installing the cooling shroud

Using system diagnostics

Removing memory modules

Related reference

Safety instructions

System Setup

Hard drives The DSS 1510 system supports one of the following::

Four hard drive systems

Up to four 3.5-inch cabled hard drives

Up to four 3.5-inch hot swappable SAS hard drives or SATA hard drives

Eight hard drive systems

Up to eight 2.5-inch hot swappable SAS hard drives, SATA hard drives, or SATA hard drives

The hot swappable hard drives connect to the system board through the hard drive backplane. Hot swappable hard drives are supplied in hot swappable hard drive carriers that fit in the hard drive slots.

CAUTION: Before attempting to remove or install a hot swappable hard drive while the system is running, see the

documentation for the storage controller card to ensure that the host adapter is configured correctly to support hot-

swap hard drive removal and insertion.

CAUTION: Do not turn off or reboot your system while the hard drive is being formatted. Doing so can cause a hard

drive failure.

NOTE: Use only hard drives that have been tested and approved for use with the hard drive backplane.

When you format a hard drive, allow enough time for the formatting to be completed. Be aware that high-capacity hard drives can take a number of hours to format.

Removing a 3.5-inch hard drive blank

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

64 Installing and removing system components

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that came with the product.

CAUTION: To maintain proper system cooling, all empty hard drive slots must have hard drive blanks installed.

1. Follow the safety guidelines listed in the Safety instructions section.

Steps

Press the release button and slide the blank out of the hard drive slot.

Figure 21. Removing a 3.5-inch hard drive blank

a. hard drive blank b. release button

Related tasks

Installing a 3.5-inch hard drive blank

Related reference

Safety instructions

Installing a 3.5-inch hard drive blank

Prerequisites

1. Follow the safety guidelines listed in the Safety instructions section.

Steps

Insert the hard drive blank into the hard drive slot until the release button clicks into place.

Installing and removing system components 65

Figure 22. Installing a 3.5-inch hard drive blank

a. hard drive blank

Related tasks

Removing a 3.5-inch hard drive blank

Related reference

Safety instructions

Removing a 3.5-inch cabled hard drive carrier

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section.

Steps

1. Disconnect the data or power cable from the hard drive.

2. Press the release tab on the hard drive carrier and slide the hard drive carrier out of the hard drive slot.

CAUTION: To maintain proper system cooling, all empty hard drive slots must have hard drive blanks installed.

3. Insert a hard drive blank in the empty hard drive slot.

66 Installing and removing system components

Figure 23. Removing a 3.5-inch cabled hard drive carrier

1. hard drive 2. power or data cable

3. release tab 4. hard drive carrier

Related tasks

Before working inside your system

Installing a 3.5-inch cabled hard drive carrier

Related reference

Safety instructions

Installing a 3.5-inch cabled hard drive carrier

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

Follow the safety guidelines listed in the Safety instructions section.

Steps

1. Press the release tab on the hard drive carrier and slide the carrier out of the system.

2. Install the hard drive into the hard drive carrier.

3. Insert the hard drive carrier into the hard drive slot until it clicks into place.

4. Connect the power/data cable to the hard drive.

If you are connecting to the integrated SATA controller (SATA hard drives only), connect the SATA data cable to the SATA_A-D connector on the system board.

If you are connecting to a SAS RAID controller card (SAS or SATA hard drives), connect the data cable to the connector on the card.

Installing and removing system components 67

Figure 24. Installing a 3.5-inch cabled hard drive carrier

1. power or data cable 2. hard drive

3. release tab 4. hard drive carrier

5. screw (4)

Next steps

1. Follow the procedure listed in the After working inside your system section. 2. Reconnect the system to its electrical outlet and turn on the system, including any attached peripherals. 3. Enter the System Setup and ensure that the hard drive's controller is enabled. 4. Exit the System Setup program and reboot the system. 5. Install any software required for the hard drive operation as described in the documentation for the hard drive.

Related tasks

After working inside your system

Removing a 3.5-inch cabled hard drive carrier

Related reference

Safety instructions

System Setup

Removing a hot swappable hard drive carrier

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that came with the product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Using the management software, prepare the hard drive for removal. For more information, see the documentation for the storage

controller.

If the hard drive is online, the green activity/fault indicator flashes when the hard drive is turned off. You can remove the hard drive when the hard drive indicators turn off.

68 Installing and removing system components

CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive installation. See the

documentation supplied with your operating system.

Steps

1. Press the release button to open the hard drive carrier release handle.

2. Slide the hard drive carrier out of the hard drive slot.

CAUTION: To maintain proper system cooling, all empty hard drive slots must have hard-drive blanks installed.

3. If you are not replacing the hard drive immediately, insert a hard drive blank in the empty hard drive slot.

Figure 25. Removing a hot swappable hard drive carrier

a. release button b. hard drive carrier c. hard drive carrier handle

Related tasks

Installing a hot-swappable hard drive carrier

Related reference

Safety instructions

Installing a hot-swappable hard drive carrier

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

CAUTION: Use only hard drives that have been tested and approved for use with the hard drive backplane.

CAUTION: Combining SAS and SATA hard drives in the same RAID volume is not supported.

CAUTION: When installing a hard drive, ensure that the adjacent drives are fully installed. Inserting a hard drive carrier

and attempting to lock its handle next to a partially installed carrier can damage the partially installed carrier's shield

spring and make it unusable.

CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive installation. See the

documentation supplied with your operating system.

Installing and removing system components 69

CAUTION: When a replacement hot swappable hard drive is installed and the system is powered on, the hard drive

automatically begins to rebuild. Make absolutely sure that the replacement hard drive is blank or contains data that you

wish to have over-written. Any data on the replacement hard drive is immediately lost after the hard drive is installed.

Steps

1. If a hard drive blank is installed in the hard drive slot, remove it.

2. Install a hard drive in the hard drive carrier.

3. Press the release button on the front of the hard drive carrier and open the hard drive carrier handle.

4. Insert the hard drive carrier into the hard drive slot until the carrier comes in contact with the backplane.

5. Close the hard drive carrier handle to lock the hard drive in place.

Figure 26. Installing a hot-swappable hard drive carrier

a. release button b. hard drive carrier c. hard drive carrier handle

Related tasks

Removing a hot swappable hard drive carrier

Related reference

Safety instructions

Installing a 2.5-inch hard drive into a 3.5-inch hard drive adapter

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Keep the Phillips #2 screwdriver ready. 3. Remove a 3.5-inch hot swappable hard drive adapter from a 3.5-inch hot swappable hard drive carrier.

Steps

1. Align the screw holes on the 2.5-inch hard drive with the screw holes on the 3.5-inch hard drive adapter.

70 Installing and removing system components

2. Install the screws to secure the hard drive to the 3.5-inch hard drive adapter.

Figure 27. Installing a 2.5-inch hard drive into a 3.5-inch hard drive adapter

a. 3.5-inch hard drive adapter b. screw (2) c. 2.5-inch hard drive

Next steps

Install the 3.5-inch adapter into the 3.5-inch hard drive carrier.

Related tasks

Installing a 3.5-inch hard drive adapter into a hot swap hard drive carrier

Removing a 2.5-inch hard drive from a 3.5-inch hard drive adapter

Related reference

Safety instructions

Removing a 2.5-inch hard drive from a 3.5-inch hard drive adapter

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that came with the product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Keep the Phillips #2 screwdriver ready. 3. Remove the 3.5-inch hard drive adapter from the 3.5-inch hot swappable hard drive carrier.

NOTE: A 2.5-inch hot swappable hard drive is installed in a 3.5-inch hard drive adapter, which is then installed in the

3.5-inch hot swappable hard drive carrier.

Steps

1. Remove the screws from the side of the 3.5-inch hard drive adapter.

2. Remove the hard drive from the 3.5-inch hard drive adapter.

Installing and removing system components 71

Figure 28. Removing a 2.5-inch hard drive from a 3.5-inch hard drive adapter

a. 3.5-inch hard drive adapter b. screw (2) c. 2.5-inch hard drive

Next steps

Install a 2.5-inch hard drive into a 3.5-inch hard drive adapter.

Related tasks

Removing a 3.5-inch hot swappable hard drive adapter from a 3.5-inch hot swappable hard drive carrier

Installing a 2.5-inch hard drive into a 3.5-inch hard drive adapter

Related reference

Safety instructions

Installing a 3.5-inch hard drive adapter into a hot swap hard drive carrier

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Keep the Phillips #2 screwdriver ready. 3. Install the 2.5-inch hot swappable hard drive into the hot swappable hard drive adapter.

Steps

1. Insert the 3.5-inch hard drive adapter into the hot swappable hard drive carrier with the connector end of the hard drive toward the back of the hot swappable hard drive carrier.

2. Align the screw holes on the hard drive with the holes on the hot swappable hard drive carrier.

3. Install the screws to secure the hot swappable hard drive to the hot swappable hard drive carrier.

72 Installing and removing system components

Figure 29. Installing a 3.5-inch hard drive adapter into a hot swappable hard drive carrier

1. 3.5-inch hard drive carrier 2. screw (5)

3. hard drive adapter 4. 2.5-inch hard drive

Next steps

1. Install the hot swappable hard drive carrier into the system.

Related tasks

Installing a 2.5-inch hard drive into a 3.5-inch hard drive adapter

Installing a hot-swappable hard drive carrier

Removing a 3.5-inch hot swappable hard drive adapter from a 3.5-inch hot swappable hard drive carrier

Related reference

Safety instructions

Removing a 3.5-inch hot swappable hard drive adapter from a 3.5-inch hot swappable hard drive carrier

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in safety instructions section. 2. Keep the Phillips #2 screwdriver ready.

Steps

1. Remove the 3.5-inch hot swappable hard drive carrier from the system.

2. Remove the screws from the rails on the hot swappable hard drive carrier.

3. Lift the 3.5-inch hard drive adapter out of the 3.5-inch hot swappable hard drive carrier.

Installing and removing system components 73

Figure 30. Removing a 3.5-inch hot swappable hard drive adapter from a 3.5-inch hot swappable hard drive carrier

1. 3.5-inch hard drive carrier 2. screw (5)

3. hard drive adapter 4. 2.5-inch hard drive

Related tasks

Removing a hot swappable hard drive carrier

Installing a 3.5-inch hard drive adapter into a hot swap hard drive carrier

Related reference

Safety instructions

Removing a hot swappable hard drive from a hard drive carrier

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

NOTE: Hot swappable hard drives are supplied in hot swappable hard drive carriers that fit in the hard drive slots.

1. Keep the Phillips #2 screwdriver ready. 2. Remove the hard drive carrier from the system.

Steps

1. Remove the screws from the side rails on the hard drive carrier.

2. Lift the hard drive out of the hard drive carrier.

Figure 31. Removing a hot swappable hard drive from a hard drive carrier

a. screw (4)

74 Installing and removing system components

b. hard drive c. hard drive carrier

Next steps

1. Install the hot swappable hard drive into the hard drive carrier. 2. Install the hot swappable hard drive carrier into the system.

Related tasks

Installing a hot-swappable hard drive carrier

Installing a hot swappable hard drive into a hard drive carrier

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

Keep the Phillips #2 screwdriver ready.

Steps

1. Insert the hard drive into the hard drive carrier with the connector end of the hard drive facing the back of the hard drive carrier.

2. Align the screw holes on the hard drive with the screw holes on the hard drive carrier.

When aligned correctly, the back of the hard drive is flush with the back of the hard drive carrier.

3. Install the screws to secure the hard drive to the hard drive carrier.

Figure 32. Installing a hard drive into a hard drive carrier

a. screw (4) b. hard drive c. hard drive carrier

Cooling fans Your system supports:

Up to four cooling fans in a non-redundant power supply unit (PSU) configuration. Up to five cooling fans in a redundant PSU configuration.

NOTE: Fan 1 must be installed in a redundant PSU configuration.

NOTE: Hot-swap removal or installation of the fans is not supported.

Installing and removing system components 75

NOTE: Each fan is listed in the systems management software, referenced by the respective fan number. If there is a

problem with a particular fan, you can easily identify and replace the proper fan by noting the fan numbers on the

cooling fan assembly.

Removing a cooling fan

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

NOTE: The procedure for removing each fan is identical.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section. 3. If installed, remove the cooling shroud.

Steps

1. Disconnect the power cable from the power cable connector on the system board or power interposer board as applicable.

2. Lift the fan out of the cooling fan bracket.

Figure 33. Removing a cooling fan

a. cooling fan b. power cable connector c. cooling fan bracket

Related tasks

Before working inside your system

Removing the cooling shroud

Installing a cooling fan

76 Installing and removing system components

Related reference

Safety instructions

Installing a cooling fan

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Remove the cooling shroud.

Steps

1. Lower the fan into the cooling fan bracket.

2. Connect the power cable to the power cable connector on the system board or power interposer board as applicable.

Figure 34. Installing a cooling fan

a. cooling fan b. power cable connector c. cooling fan bracket

Next steps

1. Install the cooling shroud. 2. Follow the procedure listed in the After working inside your system section.

Related tasks

Removing the cooling shroud

Installing the cooling shroud

After working inside your system

Removing a cooling fan

Installing and removing system components 77

Related reference

Safety instructions

Expansion cards and expansion card riser An expansion card in the server is an add-on card that can be inserted into an expansion slot on the system board or riser card to add enhanced functionality to the system through the expansion bus.

NOTE: A System Event Log (SEL) event is logged if an expansion card riser is unsupported or missing. It does not

prevent your system from turning on and no BIOS POST message or F1/F2 pause is displayed.

Expansion card installation guidelines Your system supports Generation 1, Generation 2, and Generation 3 cards. The following table provides riser configurations for DSS 1510 systems:

Table 29. Expansion card slots available on the expansion card riser

Expansion card riser

PCIe slot on the expansion card riser

Processor connection

Height Length Link width Slot width

PCIE_G3_X8 1 Processor 1 Half Height Half Length x8 x16

2 Processor 1 Half Height Half Height x8 x16

NOTE: The expansion cards are not hot swappable.

The following table provides a guide for installing expansion cards to ensure proper cooling and mechanical fit. The expansion cards with the highest priority must be installed first using the slot priority indicated. All other expansion cards must be installed in card priority and slot priority order.

Table 30. Expansion card installation order

Card priority Card type Slot priority Maximum allowed

1 RAID 2 1

2 56 Gb Infiniband NICs 1 1

3 10 Gb NICs 1, 2 2

4 1 Gb NICs 1, 2 2

Removing the expansion card riser

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section.

Steps

Holding the touch points, lift the expansion card riser from the riser connector on the system board.

78 Installing and removing system components

Figure 35. Removing the expansion card riser

1. expansion card riser 2. touch points on the riser

3. slot on the chassis 4. riser connector on the system board

Next steps

1. Install the expansion card riser. 2. Follow the procedure listed in the After working inside your system section.

Related tasks

Before working inside your system

Installing the expansion card riser

After working inside your system

Related reference

Safety instructions

Installing the expansion card riser

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. If applicable, reinstall the expansion card into the expansion card riser.

Steps

1. Align the expansion card riser latch with the slot on the chassis.

2. Lower the expansion card riser until the expansion card riser is firmly seated in the connector, on the system board.

Installing and removing system components 79

Figure 36. Installing the expansion card riser

1. expansion card riser 2. touch points on the riser

3. slot on the chassis 4. riser connector on the system board

Next steps

Follow the procedure listed in the After working inside your system section.

Related tasks

Removing an expansion card

Installing an expansion card

After working inside your system

Removing the expansion card riser

Related reference

Safety instructions

Removing an expansion card

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section.

Steps

1. Disconnect any cables connected to the expansion card or expansion card riser.

2. If installed, remove the expansion card riser.

80 Installing and removing system components

3. Hold the expansion card by its edges and remove it from the expansion card connector on the riser.

4. If you are removing the card permanently, install a metal filler bracket over the empty expansion slot and close the expansion card latch.

NOTE: You must install a filler bracket over an empty expansion card slot to maintain Federal Communications

Commission (FCC) certification of the system. The brackets also keep dust and dirt out of the system and aid in

proper cooling and airflow inside the system.

Figure 37. Removing the expansion card

a. expansion card riser b. expansion card latch c. expansion card

Next steps

Follow the procedure listed in the After working inside your system section.

Related tasks

Before working inside your system

Removing the expansion card riser

After working inside your system

Installing an expansion card

Related reference

Safety instructions

Installing an expansion card

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section.

Steps

1. Locate the expansion card connector on the riser.

Installing and removing system components 81

2. Holding the card by its edges, position the card so that the card edge connector aligns with the connector on the expansion card riser.

3. Insert the card edge connector into the expansion card connector until the card is firmly seated.

NOTE: Ensure that the expansion card is properly seated along the chassis, so that expansion card latch can be

closed.

4. If applicable, connect the cables to the expansion card.

5. Install the expansion card riser on the system board.

Figure 38. Installing an expansion card

a. expansion card riser b. expansion card latch c. expansion card

Next steps

Follow the procedure listed in the After working inside your system section.

Related tasks

Before working inside your system

Installing the expansion card riser

After working inside your system

Removing an expansion card

Related reference

Safety instructions

Remote management port card (optional) The remote management port card is used for advanced management of the system.

Removing the optional remote management port card

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

82 Installing and removing system components

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section. 3. If applicable, disconnect the cables from expansion card(s). 4. Remove the expansion card riser.

NOTE: If applicable, close the expansion card latch on the cooling shroud to release the full length card.

5. Remove the cooling shroud. 6. Keep the Phillips #2 screwdriver ready.

Steps

1. Disconnect the management network cable from the remote management port.

2. Loosen the two screws securing the remote management port card holder to the system board.

3. Pull the remote management port card up and toward the front of the system to disengage it from the connector and remove the card from the chassis.

Figure 39. Removing the optional remote management port card

1. remote management port card holder 2. remote management port

3. remote management port card 4. screw (2)

5. remote management port card connector on the system board

Next steps

1. Install the expansion card riser. 2. If applicable, connect the required power or data cables to the expansion card(s). 3. Install the cooling shroud. 4. If applicable, open the expansion card latch on the cooling shroud to support the full length expansion card. 5. Follow the procedure listed in the After working inside your system section.

Related tasks

Before working inside your system

Removing the expansion card riser

Removing the cooling shroud

Installing the expansion card riser

Installing and removing system components 83

Installing the cooling shroud

After working inside your system

Installing the optional remote management port card

Related reference

Safety instructions

Installing the optional remote management port card

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section. 3. Remove the cooling shroud.

NOTE: If applicable, close the expansion card latch on the cooling shroud to release the full length card.

4. If applicable, disconnect the cables from expansion card(s). 5. If applicable, remove the expansion card riser.

Steps

1. Align and insert the tabs on the remote management port card on the slots on the chassis wall.

2. Insert the remote management port card into the connector on the system board.

3. Tighten the screws to secure the remote management port card.

Figure 40. Installing the optional remote management port card

1. remote management port card holder 2. remote management port

3. remote management port card 4. screw (2)

84 Installing and removing system components

5. remote management port card connector on the system board

Next steps

1. If removed, reinstall the PCIe expansion card riser. 2. If disconnected, connect the cables to the expansion card(s). 3. Reinstall the cooling shroud. 4. If required, open the expansion card latch on the cooling shroud to secure the full length expansion card. 5. Follow the procedure listed in the After working inside your system section.

Related tasks

Before working inside your system

Removing the cooling shroud

Removing the expansion card riser

Installing the expansion card riser

Installing the cooling shroud

After working inside your system

Removing the optional remote management port card

Related reference

Safety instructions

Processors and heat sinks NOTE: For the 140 W heat sink, the larger part of the heat sink should be fixed on CPU1 and the smaller part on CPU2.

Use the following procedure when:

Removing and installing a heat sink Installing an additional processor Replacing a processor

Table 31. Processor wattage and heat sink dimensions

Processor Heat sink

Heat sink (dimensions) Heat sink type

Up to 135 W (Intel Xeon E5 2600 v3 or v4 product family processors)

84 mm x 106 mm x 22.7 mm single heat sink

140 W (Intel Xeon E5-1600 v3 or v4 product family processors)

84 mm x 106 mm x 28.7 mm

81 mm x 99 mm x 28.7 mm dual heat sink

Removing a heat sink

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

CAUTION: Never remove the heat sink from a processor unless you intend to remove the processor. The heat sink is

necessary to maintain proper thermal conditions.

NOTE: This is a Field Replaceable Unit (FRU). Removal and installation procedures should be performed only by Dell

certified service technicians.

Installing and removing system components 85

NOTE: To ensure proper system cooling, you must install a processor blank in any empty processor socket.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section. 3. If connected, disconnect the cables from expansion card(s). 4. If required, remove the PCIe expansion card riser. 5. Remove the cooling shroud.

NOTE: If applicable, close the expansion card latch on the cooling shroud to release the full length card.

6. Keep the Phillips #2 screwdriver ready.

WARNING: The heat sink will be hot to touch for some time after the system has been powered down. Allow the heat

sink to cool before removing it.

Steps

1. To remove a heat sink of up to 135 W, perform the following steps.

a) Loosen one of the screws that secure the heat sink to the system board.

Allow some time (approximately 30 seconds) for the heat sink to loosen from the processor. b) Loosen the screw that is diagonally opposite the screw that you first loosened. c) Repeat the procedure for the remaining screws.

Figure 41. Removing the heat sink (up to 135 W)

1. captive screw (4) 2. heat sink

3. processor socket 4. screw hole (4)

2. To remove a 140 W heat sink, perform the following steps.

a) Loosen the screw (1), that secures the heat sink over CPU1.

Allow some time (approximately 30 seconds) for the heat sink to loosen from the processor. b) Loosen the screw (2), that is diagonally opposite the screw that you first loosened. c) Repeat the procedure for the remaining four screws following the order that they are numbered.

86 Installing and removing system components

Figure 42. Removing the heat sink (140 W)

1. heat sink 2. captive screw (6) 3. processor shield

Next steps

Remove the processor.

Related tasks

Before working inside your system

Removing the expansion card riser

Removing the cooling shroud

Removing a processor

Installing a heat sink

Related reference

Safety instructions

Removing a processor

Prerequisites

WARNING: The processor is hot to touch for some time after the system has been powered down. Allow the processor

to cool before removing it.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

CAUTION: The processor is held in its socket under strong pressure. Be aware that the release lever can spring up

suddenly if not firmly grasped.

NOTE: This is a Field Replaceable Unit (FRU). Removal and installation procedures should be performed only by Dell

certified service technicians.

Installing and removing system components 87

NOTE: To ensure proper system cooling, you must install a processor blank in any empty processor socket.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section. 3. If you are upgrading your system (from a single processor system to a dual processor system or a processor with a higher processor

bin), download the latest system BIOS version from Dell.com/support and follow the instructions included in the compressed download file to install the update on your system.

4. If connected, disconnect the cables from expansion card(s). 5. If installed, remove the PCIe expansion card riser. 6. Remove the cooling shroud. 7. Remove the heat sink. 8. Keep the Phillips #2 screwdriver ready.

Steps

1. Using a clean, lint-free cloth remove any thermal grease from the surface of the processor shield.

CAUTION: The processor is held in its socket under strong pressure. Be aware that the release lever can spring up

suddenly if not firmly grasped.

2. Position your thumb firmly over the socket-release lever 1 and lever 2 of the processor and release both the levers simultaneously from the locked position by pushing down and out from under the tab.

Figure 43. Processor shield opening and closing lever sequence

a. socket-release lever 1 b. processor c. socket-release lever 2

3. Hold the tab on the processor shield and rotate the shield upward and out of the way.

4. Lift the processor out of the socket and leave the release lever up so that the socket is ready for the new processor.

CAUTION: If you are permanently removing a processor, you must install a socket protective cap and a processor

blank in the vacant socket to ensure proper system cooling. The processor blank covers the vacant sockets for the

DIMMs and the processor.

88 Installing and removing system components

Figure 44. Removing a processor

1. socket-release lever 1 2. pin1 corner of the processor

3. processor 4. slot (4)

5. processor shield 6. socket-release lever 2

7. processor socket 8. tab (4)

Next steps

1. Install a processor. 2. Install the heat sink. 3. If removed, reinstall the PCIe expansion card riser. 4. If disconnected, reconnect the cables to the expansion card(s). 5. Reinstall the cooling shroud. 6. Follow the procedure listed in the After working inside your system section.

Related tasks

Before working inside your system

Removing the expansion card riser

Removing the cooling shroud

Removing a heat sink

Installing a processor

Installing a heat sink

Installing the expansion card riser

Installing the cooling shroud

After working inside your system

Related reference

Safety instructions

Installing and removing system components 89

Installing a processor

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

NOTE: This is a Field Replaceable Unit (FRU). Removal and installation procedures should be performed only by Dell

certified service technicians.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section. 3. If you are upgrading your system (from a single processor system to a dual processor system or a processor with a higher processor

bin) download the latest system BIOS version from Dell.com/support and follow the instructions included in the compressed download file to install the update on your system.

4. Keep the Phillips #2 screwdriver ready.

NOTE: If you are installing a single processor, it must be installed in socket CPU 1.

Steps

1. Unpack the new processor.

2. Locate the processor socket.

3. Unlatch and rotate the socket-release levers 90 degrees upward and ensure that the socket-release lever is fully open.

4. Hold the tab on the processor shield and lift the shield and move it out of the way.

5. If installed, remove the socket protective cap from the processor shield. To remove the socket protective cap, push the cap from the inside of the processor shield and move it away from the socket pins.

CAUTION: Positioning the processor incorrectly can permanently damage the system board or the processor. Be

careful not to damage the pins in the socket.

CAUTION: Do not use force to seat the processor. When the processor is positioned correctly, it engages easily into

the socket.

NOTE: It is recommended that you install or remove the socket protective cap from the processor shield with the

processor shield in the open position.

6. Install the processor in the socket:

a) Identify the pin-1 corner of the processor by locating the tiny gold triangle on one corner of the processor. Place this corner in the same corner of the ZIF (Zero Insertion Force) socket identified by a corresponding triangle on the system board.

b) Install the processor into the socket such that the slots on the processor align with the socket keys.

CAUTION: The system uses a ZIF processor socket. Do not use force to seat the processor. When the processor

is positioned correctly, it engages easily into the socket.

c) Close the processor shield. d) Rotate the socket-release lever 1 and lever 2 simultaneously until they are locked into position.

90 Installing and removing system components

Figure 45. Installing a processor

1. socket-release lever 1 2. pin1 corner of the processor

3. processor 4. slot (4)

5. processor shield 6. socket-release lever 2

7. processor socket 8. tab (4)

Next steps

NOTE: Ensure that you install the heat sink after you install the processor. The heat sink is necessary to maintain proper

thermal conditions.

1. Install the heat sink. 2. Follow the procedure listed in the After working inside your system section.

Related tasks

Before working inside your system

Installing a heat sink

After working inside your system

Removing a processor

Related reference

Safety instructions

Installing a heat sink

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

Installing and removing system components 91

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

NOTE: This is a Field Replaceable Unit (FRU). Removal and installation procedures should be performed only by Dell

certified service technicians.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section. 3. Install the processor. 4. Keep the Phillips #2 screwdriver ready.

NOTE: If you are installing a single processor, it must be installed in socket CPU 1.

Steps

1. If you are using an existing heat sink, remove the thermal grease from the heat sink by using a clean lint-free cloth.

2. Using the thermal grease syringe included with your processor kit, apply the grease in a thin spiral on the top of the processor as shown in the figure.

CAUTION: Applying too much thermal grease can result in excess grease coming in contact with and contaminating

the processor socket.

NOTE: The thermal grease syringe is intended for one-time use only. Dispose of the syringe after you use it.

Figure 46. Applying thermal grease on the top of the processor

a. processor b. thermal grease c. thermal grease syringe

3. Place the heat sink on the processor.

4. To install a heat sink of up to 135 W, perform the following steps.

a) Tighten one of the screws to secure the heat sink to the system board. b) Tighten the screw diagonally opposite to the first screw that you tightened.

92 Installing and removing system components

NOTE: Do not over-tighten the heat sink retention screws when installing the heat sink. To prevent over-

tightening, tighten the retention screw until resistance is felt. The screw tension should be not more than 6 in-lb

(6.9 cm-kg).

c) Repeat the procedure for the remaining screws.

Figure 47. Installing a heat sink (up to 135 W)

1. captive screw (4) 2. heat sink

3. processor socket 4. screw hole (4)

5. To install the 140 W heat sink perform the following steps.

a) Tighten one of the screws (1) over CPU1 to secure the heat sink to the system board. b) Tighten the screw (2) diagonally opposite to the first screw that you tightened.

NOTE: Do not over-tighten the heat sink retention screws when installing the heat sink. To prevent over-

tightening, tighten the retention screw until resistance is felt. The screw tension should be not more than 6 in-lb

(6.9 cm-kg).

c) Repeat the procedure for the remaining four screws following the order that they are numbered.

Figure 48. Installing the heat sink (140 W)

1. heat sink 2. captive screw (6) 3. processor shield

Installing and removing system components 93

Next steps

1. If removed, reinstall the PCIe expansion card riser. 2. If disconnected, reconnect the cables to the expansion card(s). 3. Reinstall the cooling shroud. 4. If required, open the expansion card latch on the cooling shroud to support the full length expansion card. 5. Follow the procedure listed in the After working inside your system section. 6. While booting, press F2 to enter System Setup and check that the processor information matches the new system configuration. 7. Run system diagnostics to verify that the new processor operates correctly.

Related tasks

Before working inside your system

Installing a processor

Installing the expansion card riser

Installing the cooling shroud

After working inside your system

Removing a heat sink

Related reference

Safety instructions

System Setup

Power supply units Your system supports the following power supply units (PSUs):

450 W AC (non-redundant) 550 W AC (redundant)

When two identical PSUs are installed, the power supply configuration is redundant (1 + 1). In redundant mode, power is supplied to the system equally from both PSUs to maximize efficiency.

When only one PSU is installed, the power supply configuration is non-redundant (1 + 0). Power is supplied to the system only by the single PSU.

NOTE: If two PSUs are used, they must be of the same type and have the same maximum output power.

NOTE: For AC PSUs, use only PSU with the Extended Power Performance (EPP) label on the back. Mixing PSUs from

previous generations of Dell servers can result in a PSU mismatch condition or failure to turn on.

Hot spare feature Your system supports the hot spare feature that significantly reduces the power overhead associated with power supply unit (PSU) redundancy.

When the hot spare feature is enabled, one of the redundant PSUs is switched to the sleep state. The active PSU supports 100 percent of the load, thus operating at higher efficiency. The PSU in the sleep state monitors output voltage of the active PSU. If the output voltage of the active PSU drops, the PSU in the sleep state returns to an active output state.

If having both PSUs active is more efficient than having one PSU in the sleep state, the active PSU can also activate the sleeping PSU.

The default PSU settings are as follows:

If the load on the active PSU is more than 50 percent, then the redundant PSU is switched to the active state. If the load on the active PSU falls below 20 percent, then the redundant PSU is switched to the sleep state.

You can configure the hot spare feature by using the iDRAC settings. For more information about iDRAC settings, see the Integrated Dell Remote Access Controller Users Guide available at Dell.com/idracmanuals.

94 Installing and removing system components

Removing a redundant power supply unit

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

CAUTION: The system requires one power supply unit (PSU) for normal operation. On power-redundant systems,

remove and replace only one PSU at a time in a system that is powered on.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Disconnect the power cable from the power source. 3. Disconnect the power cable from the PSU and remove the straps that bundle and secure the system cables. 4. Unlatch and lift the optional cable management arm if it interferes with PSU removal. For information about the cable management

arm, see the systems rack documentation at Dell.com/poweredgemanuals.

Steps

Press the release latch and pull the PSU out of the chassis.

Figure 49. Removing a redundant PSU

1. release latch 2. PSU connector

3. PSU 4. power connector

5. PSU handle

Next steps

Install the PSU.

NOTE: If you are removing the PSU permanently, install a PSU blank.

Related tasks

Installing a redundant power supply unit

Installing the power supply unit blank

Related reference

Safety instructions

Getting help

Using system diagnostics

Installing and removing system components 95

Installing a redundant power supply unit

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Verify that both power supply units (PSUs) are of the same type and have the same maximum output power.

NOTE: The maximum output power (shown in Watt) is listed on the PSU label.

3. If installed, remove the PSU blank.

Steps

Slide the new PSU into the chassis until the PSU is fully seated and the release latch snaps into place.

Figure 50. Installing a redundant PSU

1. release latch 2. PSU cable connector

3. PSU 4. power connector

5. PSU handle

Next steps

1. If you have unlatched the cable management arm, relatch it. For information about the cable management arm, see the rack documentation of the system.

2. Connect the power cable to the PSU and plug the cable into a power outlet.

CAUTION: When connecting the power cable, secure the cable with the strap.

NOTE: When installing, hot-swapping, or hot-adding a new PSU in a system with two PSUs, allow several seconds

for the system to recognize the PSU and determine its status. The PSU status indicator turns green to signify that

the PSU is functioning properly.

Related tasks

Removing the power supply unit blank

Removing a redundant power supply unit

Related reference

Safety instructions

96 Installing and removing system components

Removing a cabled power supply unit

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section. 3. Disconnect the power cable from the power source. 4. Disconnect the power cable from the power supply unit (PSU) and remove the straps that bundle and secure the system cables.

NOTE: You may have to unlatch and lift the optional cable management arm if it interferes with the PSU removal. For

information about the cable management arm, see the systems rack documentation.

Steps

1. Disconnect all the power cables from the PSU to the system board, hard drives.

2. Remove the screw securing the PSU to the chassis, slide and lift the PSU out of the chassis.

Figure 51. Removing a cabled PSU

1. PSU 2. screw

3. P1 cable connector 4. P2 cable connector

5. P3 cable connector 6. standoff

7. Backplane connector

Related tasks

Before working inside your system

Installing a cabled power supply unit

Related reference

Safety instructions

Installing and removing system components 97

Installing a cabled power supply unit

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section.

NOTE: A hot-swappable non-redundant power supply unit (PSU) must be installed in Slot 1 of the PSU slot.

Steps

1. Slide the PSU into the PSU slot.

2. Align the screw hole on the PSU with the standoff on the chassis.

3. Tighten the screw to secure the PSU to the chassis.

4. Connect all the power cables to the system board, hard drives.

Figure 52. Installing a cabled PSU

1. PSU 2. screw

3. P1 cable connector 4. P2 cable connector

5. P3 cable connector 6. standoff

7. Backplane connector

Next steps

1. Follow the procedure listed in the After working inside your system section. 2. Connect the power cable to the PSU and plug the cable into a power outlet.

Related tasks

Before working inside your system

98 Installing and removing system components

After working inside your system

Removing a cabled power supply unit

Related reference

Safety instructions

Removing the power supply unit blank Install the power supply unit (PSU) blank only in the second PSU bay.

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

Follow the safety guidelines listed in the Safety instructions section.

Steps

If you are installing a second power supply unit (PSU), remove the PSU blank in the bay by pulling the blank outward.

CAUTION: To ensure proper system cooling, the PSU blank must be installed in the second PSU bay in a non-redundant

configuration. Remove the PSU blank only if you are installing a second PSU.

Figure 53. Removing the PSU blank

a. PSU blank b. PSU bay

Next steps

Install the PSU or PSU blank.

Related tasks

Installing a redundant power supply unit

Installing the power supply unit blank

Related reference

Safety instructions

Installing and removing system components 99

Installing the power supply unit blank Install the power supply unit (PSU) blank only in the second PSU bay.

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section.

Steps

Align the power supply unit blank with the power supply unit slot and push it into the power supply unit slot until it clicks into place.

Figure 54. Installing the PSU blank

a. PSU blank b. PSU bay

Related tasks

Removing the power supply unit blank

Related reference

Safety instructions

System battery The system battery is used for low-level system functions like powering the real-time clock and storing the computers BIOS settings.

Replacing the system battery

Prerequisites

NOTE: There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery only with the same

or equivalent type recommended by the manufacturer. For more information, see the safety information that shipped

with your system.

100 Installing and removing system components

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section. 3. Keep the plastic scribe ready. 4. Remove the cooling shroud.

NOTE: If applicable, close the expansion card latch on the cooling shroud to release the full length card.

5. If applicable, disconnect the power or data cables from expansion card(s). 6. If applicable, remove the expansion card riser.

Steps

1. Locate the battery socket, see the System board connectors section.

CAUTION: To avoid damage to the battery connector, you must firmly support the connector while installing or

removing a battery.

2. Use a plastic scribe to pry out the system battery as shown in the illustration below.

Figure 55. Removing the system battery

a. plastic scribe b. positive side of battery c. socket

3. To install a new system battery, hold the battery with the positive side facing up and slide it under the securing tabs.

4. Press the battery into the connector until it snaps into place.

Figure 56. Installing the system battery

a. positive side of battery b. socket

Installing and removing system components 101

Next steps

1. If applicable, install the PCIe expansion card riser. 2. If applicable, connect the required power or data cables to the expansion card(s). 3. Reinstall the cooling shroud. 4. If applicable, open the expansion card latch on the cooling shroud to secure the full length expansion card. 5. Follow the procedure listed in the After working inside your system section. 6. While booting, press F2 to enter the System Setup and ensure that the battery is operating properly. 7. Enter the correct time and date in the System Setup Time and Date fields. 8. Exit the System Setup.

Related tasks

Before working inside your system

Removing the cooling shroud

Removing the expansion card riser

Installing the expansion card riser

Installing the cooling shroud

After working inside your system

Related reference

Safety instructions

System Setup

Hard drive backplane The DSS 1510 system supports one of the following:

Four 3.5-inch or 2.5-inch SAS/SATA backplane Eight 2.5-inch SAS/SATA backplane

Removing the hard drive backplane

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

CAUTION: To prevent damage to the drives and backplane, you must remove the hard drives from the system before

removing the backplane.

CAUTION: You must note the number of each hard drive and temporarily label them before removal so that you can

replace them in the same locations.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section. 3. Remove all hard drives.

Steps

1. Disconnect the SAS/SATA data, signal, and power cable(s) from the backplane.

2. Press the release tabs, lift the backplane upward, and then slide it toward the back of the chassis.

102 Installing and removing system components

Figure 57. Removing the four 3.5-inch hard drive SAS/SATA backplane

1. guide (2) 2. hard drive/SSD backplane

3. release tab (2) 4. backplane power cable

5. backplane signal cable 6. SAS_A connector on the backplane

7. hard drive/SSD connector (4)

Installing and removing system components 103

Figure 58. Cabling diagramFour 3.5-inch (x4) hard drive SAS/SATA backplane

1. SW_RAID_A connector on the system board 2. cable routing latch

3. SAS_A connector on the backplane 4. hard drive backplane

5. system board

104 Installing and removing system components

Figure 59. Removing the eight 2.5-inch SAS/SATA backplane

1. hard drive/SSD backplane 2. backplane power cable

3. backplane signal cable 4. SAS_A cable connector

5. release tab (2) 6. SAS_B cable connector

7. hard drive/SSD connector (8)

Figure 60. Cabling diagramEight 2.5-inch SAS/SATA backplane

1. expansion card 2. SAS_ B connector on the expansion card

3. SAS_ A connector on the expansion card 4. cable routing latch

Installing and removing system components 105

5. SAS_A connector on the backplane 6. SAS_ B connector on the backplane

7. hard drive/SSD backplane 8. system board

Related tasks

Before working inside your system

Removing a hot swappable hard drive carrier

Installing the hard drive backplane

Related reference

Safety instructions

Installing the hard drive backplane

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

CAUTION: To prevent damage to the control panel flex cable, do not to bend the control panel flex cable after it is

inserted into the connector.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section.

Steps

1. Use the hooks on the chassis as guides to align the hard drive backplane.

2. Slide down the hard drive backplane until the release tabs snap into place.

3. Connect the SAS/SATA/SSD data, signal, and power cables to the backplane.

Figure 61. Installing the four 3.5-inch hard drive SAS/SATA backplane

1. guide (2) 2. hard drive/SSD backplane

106 Installing and removing system components

3. release tab (2) 4. backplane power cable

5. backplane signal cable 6. SAS_A connector on the backplane

7. hard drive/SSD connector (4)

Figure 62. Installing the eight 2.5-inch SAS/SATA backplane

1. hard drive/SSD backplane 2. backplane power cable

3. backplane signal cable 4. SAS_A cable connector

5. release tab (2) 6. SAS_B cable connector

7. hard drive/SSD connector (8)

Next steps

1. Install the hard drives in their original locations. 2. Follow the procedure listed in the After working inside your system section.

Related tasks

Before working inside your system

Installing a hot-swappable hard drive carrier

Removing the hard drive backplane

Related reference

Safety instructions

Control panel The control panel contains the power button, the diagnostic indicators, and the front USB ports.

Removing the control panel

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

Installing and removing system components 107

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section. 3. Keep the Phillips #2 screwdriver handy.

Steps

1. Using a Phillips #2 screwdriver, remove the screw(s) securing the control panel to the chassis.

CAUTION: Do not use excessive force when removing the control panel as it can damage the connectors.

2. Release the locking tabs of the control panel by angling up the control panel and away from the system.

3. Remove all the cables connecting the control panel to the chassis.

Figure 63. Removing the control panelfour 3.5-inch hard drive chassis

a. control panel b. notches (6)

108 Installing and removing system components

Figure 64. Removing the control paneleight 2.5-inch hard drive chassis

a. control panel b. notches (6)

Next steps

1. Replace the control panel. 2. Follow the procedure listed in the After working inside your system section.

Related tasks

Before working inside your system

Installing the control panel

Related reference

Safety instructions

Installing the control panel

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Keep the Phillips #2 screwdriver handy.

Steps

Align the locking tabs on the control panel with the notches on the chassis and angle the control panel until it snaps into place. When properly seated, the control panel is flush with the front panel.

Installing and removing system components 109

Figure 65. Installing the control panelfour 3.5-inch hard drive chassis

a. control panel b. notches (6)

Figure 66. Installing the control paneleight 2.5-inch hard drive chassis

a. control panel b. notches (6)

Next steps

Follow the procedure listed in the After working inside your system section.

Related tasks

After working inside your system

Removing the control panel

Related reference

Safety instructions

Removing the control panel module

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

110 Installing and removing system components

1. Follow the safety guidelines listed in the Safety instructions section 2. Follow the procedure listed in the Before working inside your system section.

CAUTION: Do not use excessive force when removing the control panel as it can damage the connectors.

Steps

1. Remove the screw(s) securing the control panel module to the chassis.

2. Disconnect all the cables connecting the control panel module to the chassis.

3. Slide the control panel module and lift it away from the system.

Figure 67. Removing the control panel modulefour hard drive chassis

a. control panel module b. screw (2) c. control panel module connector cable

Installing and removing system components 111

Figure 68. Removing the control panel moduleeight hard drive chassis

a. control panel module b. screw (2) c. control panel module connector cable

Related tasks

Before working inside your system

Installing the control panel module

Related reference

Safety instructions

Installing the control panel module

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section.

Steps

1. Insert the control panel module into the slot in the chassis and align the two screw holes on the control panel module with the corresponding holes on the chassis.

2. Secure the control panel module with the screws.

3. Connect all the applicable cables to the control panel module.

112 Installing and removing system components

Figure 69. Installing the control panel modulefour hard drive chassis

a. control panel module b. screw (2) c. control panel module connector cable

Figure 70. Installing the control panel moduleeight hard drive chassis

a. control panel module b. screw (2) c. control panel module connector cable

Next steps

Follow the procedure listed in the After working inside your system section.

Installing and removing system components 113

Related tasks

Before working inside your system

After working inside your system

Removing the control panel module

Related reference

Safety instructions

Power interposer board The power interposer board (PIB) is a board that connects the redundant power supply units (PSUs) to the system board. The PIB is only supported in systems with redundant PSUs.

Removing the power interposer board

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

NOTE: The power interposer board (PIB) is present only in systems that support redundant power supply units (PSUs).

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section. 3. Remove the PSUs from the system.

Steps

1. Disconnect the power distribution cables from the system board.

2. Disconnect the fan cable.

3. Remove the two screws securing the PIB to the chassis and lift the board out of the chassis.

Figure 71. Removing the PIB

1. standoffs (2) 2. PIB

114 Installing and removing system components

3. fan cable connector 4. screw (2)

5. PSU cables to the system board (3)

Related tasks

Before working inside your system

Removing a cabled power supply unit

Installing the power interposer board

Related reference

Safety instructions

Installing the power interposer board

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

Follow the safety guidelines listed in the Safety instructions section.

Steps

1. Align the power interposer board (PIB) with the standoffs on the chassis.

2. Install the two screws that secure the PIB to the chassis.

3. Connect the power distribution cables to the system board and fan cable connector to the PIB.

Figure 72. Installing the PIB

1. standoffs (2) 2. PIB

3. fan cable connector 4. screw (2)

5. power supply cables to the system board (3)

Next steps

Follow the procedure listed in the After working inside your system section.

Installing and removing system components 115

Related tasks

After working inside your system

Removing the power interposer board

Related reference

Safety instructions

System board A system board (also known as the motherboard) is the main printed circuit board found in systems. The system board allows communication between many of the crucial electronic components of the system, such as the central processing unit (CPU) and memory, and also provides connectors for other peripherals. Unlike a backplane, a system board contains significant number of sub- systems such as the processor expansion cards, and other components.

Removing the system board

Prerequisites

1. Follow the safety guidelines listed in the Safety instructions section 2. Follow the procedure listed in the Before working inside your system section. 3. Remove or disconnect the following components:

a. cooling shroud b. cooling fans c. power supply unit(s) d. expansion card riser(s) e. integrated storage controller card f. heat sink(s)/heat sink blank(s) g. processors(s)/processor blank(s)

CAUTION: To prevent damage to the processor pins when replacing a faulty system board, ensure that you cover

the processor socket with the processor protective cap.

h. memory modules and memory module blanks 4. Keep the Phillips #2 screwdriver ready.

Steps

1. Disconnect the SAS cable from the system board.

2. Disconnect all other data and power cables from the system board.

CAUTION: Take care not to damage the system identification button while removing the system board from the

chassis.

CAUTION: Do not lift the system board by holding a memory module, processor, or other components.

3. Remove the screws securing the system board to the chassis.

116 Installing and removing system components

Figure 73. Screw location on the system board

a. screw (9)

4. Lift the system board and slide it toward the front of the chassis.

Installing and removing system components 117

Figure 74. Removing the system board

a. system board

Related tasks

Before working inside your system

Removing the cooling shroud

Removing a cooling fan

Removing a cabled power supply unit

Removing the expansion card riser

Removing a heat sink

Removing a processor

Removing memory modules

Installing the system board

Related reference

Safety instructions

Installing the system board

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

118 Installing and removing system components

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section. 3. Keep the Phillips #2 screwdriver ready.

Steps

1. Unpack the new system board assembly.

CAUTION: Do not lift the system board by holding a memory module, processor, or other components.

CAUTION: Take care not to damage the system identification button while placing the system board into the chassis.

2. Hold the touch points and lower the system board into the chassis.

3. Push the system board toward the back of the chassis until the board clicks into place.

Figure 75. Installing the system board

a. system board

4. Tighten the screws to secure the system board to the chassis.

Installing and removing system components 119

Figure 76. Screw location on the system board

a. screw (9)

Next steps

1. Install / connect the following components:

a. the expansion card riser b. heat sink(s) and processors(s) c. processor blank(s) and heat sink blank(s), if installed d. memory modules and memory module blanks e. cooling fans f. cooling shroud g. power supply unit(s)

2. Reconnect all cables to the system board.

NOTE: Ensure that the cables inside the system are routed along the chassis wall .

3. Follow the procedure listed in the After working inside your system section. 4. Ensure that you:

a. Use the Easy Restore feature to restore the service tag. b. Update the BIOS and iDRAC versions.

Related tasks

Before working inside your system

Installing the cooling shroud

Installing a cooling fan

Installing the expansion card riser

Installing a cabled power supply unit

120 Installing and removing system components

Installing a heat sink

Installing a processor

Installing memory modules

After working inside your system

Removing the system board

Related reference

Safety instructions

Entering the system Service Tag by using System Setup If Easy Restore fails to restore the Service Tag, use System Setup to enter the Service Tag.

Steps

1. Turn on the system.

2. Press F2 to enter System Setup.

3. Click Service Tag Settings.

4. Enter the Service Tag.

NOTE: You can enter the Service Tag only when the Service Tag field is empty. Ensure that you enter the correct

Service Tag. After the Service Tag is entered, it cannot be updated or changed.

5. Click Ok.

6. Import your new or existing iDRAC Enterprise license.

For more information, see the Integrated Dell Remote Access Controller User's Guide at Dell.com/idracmanuals.

Restoring the Service Tag by using the Easy Restore feature The Easy Restore feature enables you to restore your systems Service Tag, license, UEFI configuration, and the system configuration data after replacing the system board. All data is automatically backed up in a backup flash device. If BIOS detects a new system board and the Service Tag in the backup flash device, BIOS prompts the user to restore the backup information.

Steps

1. Turn on the system. If BIOS detects a new system board, and if the Service Tag is present in the backup flash device, BIOS displays the Service Tag, the status of the license, and the UEFI Diagnostics version.

2. Perform one of the following steps:

Press Y to restore the Service Tag, license, and diagnostics information.

After the restore process is complete, BIOS prompts to restore the system configuration data.

3. Perform one of the following steps:

Press Y to restore the system configuration data. Press N to use the default configuration settings.

After the restore process is complete, the system restarts.

Installing and removing system components 121

Using system diagnostics If you experience a problem with your system, run the system diagnostics before contacting Dell for technical assistance. The purpose of running system diagnostics is to test your system hardware without requiring additional equipment or risking data loss. If you are unable to fix the problem yourself, service and support personnel can use the diagnostics results to help you solve the problem. Topics:

Dell Embedded System Diagnostics

Dell Embedded System Diagnostics NOTE: The Dell Embedded System Diagnostics is also known as Enhanced Pre-boot System Assessment (ePSA)

diagnostics.

The Embedded System Diagnostics provides a set of options for particular device groups or devices allowing you to:

Run tests automatically or in an interactive mode Repeat tests Display or save test results Run thorough tests to introduce additional test options to provide extra information about the failed device(s) View status messages that inform you if tests are completed successfully View error messages that inform you of problems encountered during testing

Running the Embedded System Diagnostics from Boot Manager

Prerequisites

Run the Embedded System Diagnostics (ePSA) if your system does not boot.

Steps

1. When the system is booting, press F11.

2. Use the up arrow and down arrow keys to select System Utilities > Launch Diagnostics. The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics starts executing the tests on all the detected devices.

System diagnostic controls Menu Description

Configuration Displays the configuration and status information of all detected devices.

Results Displays the results of all tests that are run.

System health Provides the current overview of the system performance.

Event log Displays a time-stamped log of the results of all tests run on the system. This is displayed if at least one event description is recorded.

7

122 Using system diagnostics

Jumpers and connectors This topic provides specific information about the system jumpers. It also provides some basic information about jumpers and switches and describes the connectors on the various boards in the system. Jumpers on the system board help to disable system and setup passwords. You must know the connectors on the system board to install components and cables correctly.

Topics:

System board jumper settings Disabling a forgotten password System board connectors and jumpers

System board jumper settings For information about resetting the password jumper to disable a password, see the Disabling a forgotten password section.

Table 32. System board jumper settings

Jumper Setting Description

PWRD_EN The password reset feature is enabled (pins 24).

The password reset feature is disabled (pins 46). The iDRAC local access is unlocked at the next AC power cycle.

NVRAM_CLR The configuration settings are retained at the next system boot (pins 35).

The configuration settings are cleared at system boot (pins 13).

Related tasks

Disabling a forgotten password

Disabling a forgotten password The software security features of the system include a system password and a setup password. The password jumper enables these password features or disables them and clears any password(s) currently in use.

Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

Steps

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the system cover.

3. Move the jumper on the system board jumper from pins 4 and 6 to pins 2 and 4.

4. Install the system cover.

The existing passwords are not disabled (erased) until the system boots with the jumper on pins 2 and 4. However, before you assign a new system and/or setup password, you must move the jumper back to pins 4 and 6.

8

Jumpers and connectors 123

NOTE: If you assign a new system and/or setup password with the jumper on pins 2 and 4, the system disables the

new password(s) the next time it boots.

5. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

6. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

7. Remove the system cover.

8. Move the jumper on the system board jumper from pins 2 and 4 to pins 4 and 6.

9. Install the system cover.

10. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

11. Assign a new system and/or setup password.

Related tasks

Removing the system cover

Installing the system cover

System board connectors and jumpers

Figure 77. System board connectors and jumpers

Table 33. System board connectors and jumpers

Item Connector Description

1 PCIE _G2_X4 (PCH) PCIE Slot 3 (x4)

2 PCIE_G3_X16 (CPU1) PCIe Slot 2 and PCIe Slot 1 (PCIe Slot is closer to the CPU2 socket)

3 J-AMEA iDrac ports card connector

4 CPU2_PWR_C (P3) CPU2 power connector

5 Int_PCIE_G3_X8 (CPU2) Internal PCIe slot

124 Jumpers and connectors

Item Connector Description

6 FAN6 Cooling fan 6 connector

7 FAN5 Cooling fan 5 connector

8 A1, A5, A2, A6 DIMMS for CPU1 channels 0&1

9 FAN4 Cooling fan 4 connector

10 CPU1 Processor socket 1

11 FAN3 Cooling fan 3 connector

12 PWR_CONN B(P2) CPU1 power connector

13 A8, A4, A7, A3 DIMMS for CPU1 channels 2&3

14 FAN2 Cooling fan 2 connector

15 BP_SIG Backplane signal connector

16 HDD_PWR Hard drive power connector

17 SYS_PWR_CONN(P1) 24-pin power connector

18 FP_USB Front panel USB connector

19 SATA_CDROM SATA connector CDROM

20 PIB_CONN Power interface board signal connector

21 SATA_TBU SATA connector tape backup unit

22 BATTERY System battery connector

23 CTRL_PNL Control panel signal connector

24 SW_RAID_A Internal SATA A connector

25 TPM_MODULE Trusted Platform Module connector

26 J_PSWD_NVRAM Clear password / NVRAM jumpers

Jumpers and connectors 125

Troubleshooting your system

Safety first for you and your system CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

NOTE: Solution validation was performed by using the factory shipped hardware configuration.

Topics:

Troubleshooting system startup failure Troubleshooting external connections Troubleshooting the video subsystem Troubleshooting a USB device Troubleshooting a serial I/O device Troubleshooting a NIC Troubleshooting a wet system Troubleshooting a damaged system Troubleshooting the system battery Troubleshooting power supply units Troubleshooting cooling problems Troubleshooting cooling fans Troubleshooting system memory Troubleshooting a hard drive Troubleshooting a storage controller Troubleshooting expansion cards Troubleshooting processors

Troubleshooting system startup failure If you boot the system to the BIOS boot mode after installing an operating system from the UEFI Boot Manager, the system stops responding. To avoid this issue, you must boot to the same boot mode in which you installed the operating system.

For all other startup issues, note the system messages that appear on the screen.

Troubleshooting external connections Before troubleshooting any external devices, ensure that all external cables are securely attached to the external connectors on your system before troubleshooting any external devices.

Troubleshooting the video subsystem Prerequisites

Steps

1. Check the cable connections (power and display) to the monitor.

9

126 Troubleshooting your system

2. Check the video interface cabling from the system to the monitor.

3. Run the appropriate diagnostic test.

Results

If the tests run successfully, the problem is not related to video hardware.

Next steps

If the tests fail, see the Getting help section.

Related reference

Getting help

Troubleshooting a USB device Prerequisites

NOTE: Follow steps 1 to 6 to troubleshoot a USB keyboard or mouse. For other USB devices, go to step 7.

Steps

1. Disconnect the keyboard and/or mouse cables from the system and reconnect them.

2. If the problem persists, connect the keyboard and/or mouse to another USB port on the system.

3. If the problem is resolved, restart the system, enter System Setup, and check if the non-functioning USB ports are enabled.

NOTE: Older operating systems may not support USB 3.0.

4. Check if USB 3.0 is enabled in System Setup. If enabled, disable it and see if the issue is resolved.

5. If the problem is not resolved, replace the keyboard and/or mouse with a known working keyboard or mouse.

If the problem is not resolved, proceed to step 7 to troubleshoot other USB devices attached to the system.

6. Turn off all attached USB devices, and disconnect them from the system.

7. Restart the system.

8. If your keyboard is functioning, enter System Setup, verify that all USB ports are enabled on the Integrated Devices screen. If your keyboard is not functioning, use remote access to enable or disable the USB options.

9. Check if USB 3.0 is enabled in System Setup. If it is enabled, disable it and restart your system.

10. If the system is not accessible, reset the NVRAM_CLR jumper inside your system and restore the BIOS to the default settings. See the System board jumper setting section

11. Reconnect and turn on each USB device one at a time.

12. If a USB device causes the same problem, turn off the device, replace the USB cable with a known good cable, and turn on the device.

Next steps

If all troubleshooting fails, see the Getting help section.

Related reference

Getting help

System Setup

System board jumper settings

Troubleshooting a serial I/O device Steps

1. Turn off the system and any peripheral devices connected to the serial port.

2. Swap the serial interface cable with a known working cable, and turn on the system and the serial device.

Troubleshooting your system 127

If the problem is resolved, replace the interface cable with a known working cable.

3. Turn off the system and the serial device, and swap the serial device with a compatible device.

4. Turn on the system and the serial device.

Next steps

If the problem persists, see the Getting help section.

Related reference

Getting help

Troubleshooting a NIC Steps

1. Run the appropriate diagnostic test. For more information, see the Using system diagnostics section for the available diagnostic tests.

2. Restart the system and check for any system messages pertaining to the NIC controller.

3. Check the appropriate indicator on the NIC connector:

If the link indicator does not glow, the cable connected might be disengaged. If the activity indicator does not glow, the network driver files might be damaged or missing.

Install or replace the drivers as necessary. For more information, see the NIC documentation. Try another known good network cable. If the problem persists, use another connector on the switch or hub.

4. Ensure that the appropriate drivers are installed and the protocols are bound. For more information, see the NIC documentation.

5. Enter System Setup and confirm that the NIC ports are enabled on the Integrated Devices screen.

6. Ensure that all the NICs, hubs, and switches on the network are set to the same data transmission speed and duplex. For more information, see the documentation for each network device.

7. Ensure that all network cables are of the proper type and do not exceed the maximum length.

Next steps

If the problem persists, see the Getting help section.

Related reference

Getting help

Using system diagnostics

Troubleshooting a wet system Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

Steps

1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the system cover.

3. Remove the following components (if installed) from the system:

Power supply unit(s) Optical drive Hard drives

128 Troubleshooting your system

Hard drive backplane USB memory key Hard drive tray Cooling shroud Expansion card risers (if installed) Expansion cards Cooling fan assembly (if installed) Cooling fans Memory modules Processor(s) and heat sink(s) System board

4. Let the system dry thoroughly for at least 24 hours.

5. Reinstall the components you removed in step 3 except the expansion cards.

6. Install the system cover.

7. Turn on the system and attached peripherals.

If the problem persists, see the Getting help section.

8. If the system starts properly, turn off the system, and reinstall all the expansion cards that you removed.

9. Run the appropriate diagnostic test. For more information, see the Using system diagnostics section.

Next steps

If the tests fail, see the Getting help section.

Related tasks

Removing the system cover

Removing the hard drive backplane

Removing the cooling shroud

Removing a cooling fan

Removing a cabled power supply unit

Removing a hot swappable hard drive carrier

Removing the expansion card riser

Removing a heat sink

Removing a processor

Removing memory modules

Removing an expansion card

Removing the system board

Installing the system cover

Related reference

Getting help

Using system diagnostics

Troubleshooting a damaged system Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

Steps

1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the system cover.

Troubleshooting your system 129

3. Ensure that the following components are properly installed:

cooling shroud expansion card risers (if installed) expansion cards power supply unit(s) cooling fan assembly (if installed) cooling fans processor(s) and heat sink(s) memory modules hard drive carriers/cage hard drive backplane

4. Ensure that all cables are properly connected.

5. Install the system cover.

6. Run the appropriate diagnostic test. For more information, see the Using system diagnostics section.

Next steps

If the problem persists, see the Getting help section.

Related tasks

Removing the system cover

Installing the cooling shroud

Installing a cooling fan

Installing the expansion card riser

Installing an expansion card

Installing a redundant power supply unit

Installing a cabled power supply unit

Installing a heat sink

Installing a processor

Installing memory modules

Installing a hot-swappable hard drive carrier

Installing the hard drive backplane

Installing the system cover

Related reference

Getting help

Using system diagnostics

Troubleshooting the system battery Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

NOTE: If the system is turned off for long periods of time (for weeks or months), the NVRAM may lose its system

configuration information. This situation is caused by a defective battery.

NOTE: Some software may cause the system time to speed up or slow down. If the system seems to operate normally

except for the time set in System Setup, the problem may be caused by a software, rather than by a defective battery.

Steps

1. Re-enter the time and date in System Setup.

130 Troubleshooting your system

2. Turn off the system, and disconnect it from the electrical outlet for at least an hour.

3. Reconnect the system to the electrical outlet, and turn on the system.

4. Enter System Setup.

If the date and time displayed in System Setup are not correct, check the System Error Log (SEL) for system battery messages.

Next steps

If the problem persists, see the Getting help section.

Related reference

Getting help

System Setup

Troubleshooting power supply units Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

Troubleshooting power source problems

Steps

1. Press the power button to ensure that your system is turned on. If the power indicator does not glow when the power button is pressed, press the power button firmly.

2. Plug in another working power supply unit to ensure that the system board is not faulty.

3. Ensure that no loose connections exist.

For example, loose power cables.

4. Ensure that the power source meets applicable standards.

5. Ensure that there are no short circuits.

6. Have a qualified electrician check the line voltage to ensure that it meets the needed specifications.

Power supply unit problems

Steps

1. Ensure that no loose connections exist.

For example, loose power cables.

2. Ensure that the power supply unit (PSU) handle or LED indicates that the PSU is working properly.

For more information about PSU indicators, see the Power indicator codes section.

3. If you have recently upgraded your system, ensure that the PSU has enough power to support the new system.

4. If you have a redundant PSU configuration, ensure that both the PSUs are of the same type and wattage.

You may have to upgrade to a higher wattage PSU.

5. Ensure that you use only PSUs with the Extended Power Performance (EPP) label on the back.

6. Reseat the PSU.

NOTE: After installing a PSU, allow several seconds for the system to recognize the PSU and determine if it is

working properly.

If the problem persists, see the Getting help section.

Troubleshooting your system 131

Related reference

Getting help

Redundant power supply unit indicator codes

Non-redundant power supply unit indicator codes

Troubleshooting cooling problems CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

Ensure that the following conditions exist:

System cover, cooling shroud, EMI filler panel, memory module blank, or back filler bracket is not removed. Ambient temperature is not higher than the system specific ambient temperature. External airflow is not obstructed. A cooling fan is not removed or has not failed. The expansion card installation guidelines have been followed.

Additional cooling can be added by one of the following methods:

From the iDRAC web GUI:

1. Click Hardware > Fans > Setup. 2. From the Fan Speed Offset drop-down list, select the cooling level required or set the minimum fan speed to a custom value.

From F2 System Setup:

1. Select iDRAC Settings > Thermal, and set a higher fan speed from the fan speed offset or minimum fan speed.

From RACADM commands:

1. Run the command racadm help system.thermalsettings For more information, see the Integrated Dell Remote Access Users Guide at Dell.com/idracmanuals.

Troubleshooting cooling fans Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

NOTE: The fan number is referenced by the systems management software. In the event of a problem with a particular

fan, you can easily identify and replace it by noting down the fan numbers on the cooling fan assembly.

1. Follow the safety guidelines listed in the Safety instructions section. 2. Follow the procedure listed in the Before working inside your system section.

Steps

1. Reseat the fan or the fan's power cable.

2. Restart the system.

Next steps

1. Follow the procedure listed in the After working inside your system section. 2. If the problem persists, see the Getting help section.

132 Troubleshooting your system

Related tasks

Before working inside your system

Removing the system cover

Installing a cooling fan

Installing the system cover

Related reference

Safety instructions

Getting help

Troubleshooting system memory Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

Steps

1. If the system is operational, run the appropriate system diagnostic test. See the Using system diagnostics section for the available diagnostic tests.

If the diagnostic tests indicate a fault, follow the corrective actions provided by the diagnostic tests.

2. If the system is not operational, turn off the system and attached peripherals, and unplug the system from the power source. Wait at least for 10 seconds, and then reconnect the system to the power source.

3. Turn on the system and attached peripherals, and note the messages on the screen.

If an error message is displayed indicating a fault with a specific memory module, go to step 12.

4. Enter System Setup, and check the system memory setting. Make any changes to the memory settings, if needed.

If the memory settings match the installed memory but the problem still persists, go to step 12.

5. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

6. Remove the system cover.

7. Check the memory channels and ensure that they are populated correctly.

NOTE: See the system event log or system messages for the location of the failed memory module. Reinstall the

memory device.

8. Reseat the memory modules in their sockets.

9. Install the system cover.

10. Enter System Setup and check the system memory setting.

If the problem is not resolved, proceed with step 11.

11. Remove the system cover.

12. If a diagnostic test or error message indicates a specific memory module as faulty, swap or replace the module with a known working memory module.

13. To troubleshoot an unspecified faulty memory module, replace the memory module in the first DIMM socket with a module of the same type and capacity.

If an error message is displayed on the screen, this may indicate a problem with the installed DIMM type(s), incorrect DIMM installation, or defective DIMM(s). Follow the on-screen instructions to resolve the problem.

14. Install the system cover.

15. As the system boots, observe any error message that is displayed and the diagnostic indicators on the front of the system.

16. If the memory problem persists, repeat step 12 through step 15 for each memory module installed.

Next steps

If the problem persists, see the Getting help section.

Troubleshooting your system 133

Related tasks

Removing the system cover

Removing memory modules

Installing memory modules

Installing the system cover

Related reference

Getting help

System Setup

Using system diagnostics

Troubleshooting a hard drive Prerequisites

CAUTION: This troubleshooting procedure can erase data stored on the hard drive. Before you proceed, back up all files

on the hard drive.

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

Steps

1. Run the appropriate diagnostic test. See the Using system diagnostics section.

Depending on the results of the diagnostics test, proceed as needed through the following steps.

2. If your system has a RAID controller and your hard drives are configured in a RAID array, perform the following steps:

a) Ensure that the hard drives are configured correctly for the RAID array. b) Take the hard drive offline and reseat the drive. c) Exit the configuration utility and allow the system to boot to the operating system.

3. Ensure that the needed device drivers for your controller card are installed and are configured correctly. See the operating system documentation for more information.

4. Restart the system and enter the System Setup.

5. Verify that the controller is enabled and the drives are displayed in the System Setup.

Next steps

If the problem persists, see the Getting help section.

Related reference

Getting help

Using system diagnostics

System Setup

Troubleshooting a storage controller CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

NOTE: When troubleshooting a SAS or PERC controller, see the documentation for your operating system and the

controller.

1. Run the appropriate diagnostic test. See the Using system diagnostics section.

134 Troubleshooting your system

2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 3. Remove the system cover. 4. Verify that the installed expansion cards are compliant with the expansion card installation guidelines. 5. Ensure that each expansion card is firmly seated in its connector. 6. Install the system cover. 7. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals. 8. If the problem is not resolved, turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 9. Remove the system cover. 10. Remove all expansion cards installed in the system. 11. Install the system cover. 12. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals. 13. Run the appropriate diagnostic test. See the Using system diagnostics section. If the tests fail, see the Getting help section. 14. For each expansion card you removed in step 10, perform the following steps:

a. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. b. Remove the system cover. c. Reinstall one of the expansion cards. d. Install the system cover. e. Run the appropriate diagnostic test. See the Using system diagnostics section.

If the problem persists, see the Getting help section.

Related tasks

Removing the system cover

Removing an expansion card

Installing an expansion card

Installing the system cover

Related reference

Getting help

Using system diagnostics

Troubleshooting expansion cards Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

NOTE: When troubleshooting an expansion card, you also have to see the documentation for your operating system and

the expansion card.

Steps

1. Run the appropriate diagnostic test. See the Using system diagnostics section.

2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

3. Remove the system cover.

4. Ensure that each expansion card is firmly seated in its connector.

5. Install the system cover.

6. Turn on the system and attached peripherals.

7. If the problem is not resolved, turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

8. Remove the system cover.

9. Remove all expansion cards installed in the system.

10. Install the system cover.

Troubleshooting your system 135

11. Run the appropriate diagnostic test. See the Using system diagnostics section.

If the tests fail, see the Getting help section.

12. For each expansion card you removed in step 8, perform the following steps:

a) Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. b) Remove the system cover. c) Reinstall one of the expansion cards. d) Install the system cover. e) Run the appropriate diagnostic test. See the Using system diagnostics section.

Next steps

If the problem persists, see the Getting help section.

Related tasks

Removing the system cover

Removing an expansion card

Installing an expansion card

Installing the system cover

Related reference

Getting help

Using system diagnostics

Troubleshooting processors Prerequisites

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

simple repairs as authorized in your product documentation, or as directed by the online or telephone service and

support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow

the safety instructions that are shipped with your product.

Steps

1. Run the appropriate diagnostics test. See the Using system diagnostics section.

2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

3. Remove the system cover.

4. Ensure that the processor and heat sink are properly installed.

5. Install the system cover.

6. Run the appropriate diagnostic test. See the Using system diagnostics section.

7. If the problem persists, see the Getting help section.

Related tasks

Removing the system cover

Installing the system cover

Related reference

Getting help

Using system diagnostics

136 Troubleshooting your system

Getting help

Topics:

Contacting Dell Documentation feedback

Contacting Dell Dell provides several online and telephone-based support and service options. If you do not have an active internet connection, you can find contact information about your purchase invoice, packing slip, bill, or Dell product catalog. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical assistance, or customer-service issues:

Steps

1. Go to Dell.com/support.

2. Select your country from the drop-down menu on the lower right corner of the page.

3. For customized support:

a) Enter your system Service Tag in the Enter your Service Tag field. b) Click Submit.

The support page that lists the various support categories is displayed.

4. For general support:

a) Select your product category. b) Select your product segment. c) Select your product.

The support page that lists the various support categories is displayed.

5. For contact details of Dell Global Technical Support:

a) Click Global Technical Support. b) The Contact Technical Support page is displayed with details to call, chat, or e-mail the Dell Global Technical Support team.

Documentation feedback You can rate the documentation or write your feedback on any of our Dell documentation pages and click Send Feedback

Manualsnet FAQs

If you want to find out how the DSS Dell works, you can view and download the Dell DSS 1510 Server Owner's Manual on the Manualsnet website.

Yes, we have the Owner's Manual for Dell DSS as well as other Dell manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Owner's Manual should include all the details that are needed to use a Dell DSS. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Dell DSS 1510 Server Owner's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Dell DSS 1510 Server Owner's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Dell DSS 1510 Server Owner's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Dell DSS 1510 Server Owner's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Dell DSS 1510 Server Owner's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.