Dell PowerEdge 850 Server Installation Guide PDF

1 of 148
1 of 148

Summary of Content for Dell PowerEdge 850 Server Installation Guide PDF

Dell PowerEdge 850 Systems Installation and Troubleshooting Guide

Introduction

Indicators, Messages, and Codes

Running the System Diagnostics

Troubleshooting Your System

Installing System Components

Installing Drives

Service-Only Parts Replacement Procedures

Getting Help

Jumpers, Switches, and Connectors

I/O Connectors

 Notes, Notices, and Cautions

 Abbreviations and Acronyms

For a complete list of abbreviations and acronyms, see the Glossary in your User's Guide.

Information in this document is subject to change without notice.  2005 Dell Inc. All rights reserved.

Reproduction in any manner whatsoever without the written permission of Dell Inc.is strictly forbidden.

Trademarks used in this text: Dell, the DELL logo, PowerEdge, PowerVault, PowerApp, Dell OpenManage, Inspiron, Dell Precision, Dimension, OptiPlex, and Latitude are trademarks of Dell Inc.; Intel, Pentium, and Celeron are registered trademarks of Intel Corporation; EMC is a registered trademark of EMC Corporation.

Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.

Initial release: April 2005

NOTE: A NOTE indicates important information that helps you make better use of your computer.

NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.

CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.

Back to Contents Page

  Jumpers, Switches, and Connectors Dell PowerEdge 800 Systems Installation and Troubleshooting Guide 

  JumpersA General Explanation

  System Board Jumpers

  System Board Connectors

  SCSI Backplane Connectors

  Disabling a Forgotten Password

This section provides specific information about the system jumpers. It also provides some basic information on jumpers and switches and describes the connectors on the various boards in the system.

 JumpersA General Explanation

Jumpers provide a convenient and reversible way of reconfiguring the circuitry on a printed circuit board. When reconfiguring the system, you may need to change jumper settings on circuit boards or drives.

Jumpers

Jumpers are small blocks on a circuit board with two or more pins emerging from them. Plastic plugs containing a wire fit down over the pins. The wire connects the pins and creates a circuit. To change a jumper setting, pull the plug off its pin(s) and carefully fit it down onto the pin(s) indicated. Figure A-1 shows an example of a jumper.

 Figure A-1. Example Jumper

A jumper is referred to as open or unjumpered when the plug is pushed down over only one pin or if there is no plug at all. When the plug is pushed down over two pins, the jumper is referred to as jumpered. The jumper setting is often shown in text as two numbers, such as 12. The number 1 is printed on the circuit board with a triangle so that you can identify each pin number based on the location of pin 1.

Figure A-2 shows the location and default settings of the server-module jumper blocks. See Table A-1 for the designations, default settings, and functions of the jumpers.

 System Board Jumpers

Figure A-2 shows the location of the configuration jumpers on the system board. Table A-1 lists the jumper settings.

 Figure A-2. System Board Jumpers

NOTE: To access the jumpers, remove the memory cooling shroud by lifting the release latch and sliding the shroud toward the front of the system. See Figure 6-1.

 Table A-1. System Board Jumper Settings 

 System Board Connectors

See Figure A-3 and Table A-2 for the location and description of the system board connectors.

 Figure A-3. System Board Connectors

Jumper

Setting

Description

PASSWD_EN    (default) The password feature is enabled.

The password feature is disabled.

NVRAM_CLR    (default) The configuration settings in NVRAM are retained at system boot.

The configuration settings in NVRAM are cleared at next system boot.

 Table A-2. System Board Connectors 

 SCSI Backplane Connectors

See Figure A-4 for the location and description of the connectors on the back of the optional SCSI backplane board.

 Figure A-4. Connectors on Back of SCSI Backplane

Connector

Description

12V Power connector

BACK_FAN Fan power connector

BATTERY Connector for the 3.0-V coin battery

BP_I2C Connector for the baseboard management controller (BMC) inter-IC (I2C) cable for the optional SCSI backplane

CPU Processor connector

DIMMn_ x Memory module connector (4)

FDD Diskette drive connector

FRONT_FAN Fan power connector

FRONT_PANEL Control panel connector

IDE IDE optical device connector

SLOT_n PCI expansion slot connector

PWR_CONN Power connector

RAC_CONN Connector for the remote access controller (RAC)

SATA_n SATA hard-drive connector

 Disabling a Forgotten Password

The system's software security features include a system password and a setup password, which are discussed in detail in "Using the System Setup Program" in your User's Guide. The password jumper enables these password features or disables them and clears any password(s) currently in use.

  1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2. Open the system. See "Opening the System" in "Troubleshooting Your System."  

3. Remove the memory cooling shroud by lifting the release latch and sliding the shroud toward the front of the system. See Figure 6-1.  

4. Remove the password jumper plug.

See Figure A-2 to locate the password jumper on the system board.

  5. Replace the memory cooling shroud.

6. Close the system. See "Closing the System" in "Troubleshooting Your System."  

7. Reconnect the system to the electrical outlet, and turn on the system.

The existing passwords are not disabled (erased) until the system boots with the password jumper plug removed. However, before you assign a new system and/or setup password, you must install the jumper plug.

  8. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

9. Open the system.  

10. Remove the memory cooling shroud.  

11. Reinstall the password jumper plug in its original position to enable the password protection feature.  

12. Reinstall the memory cooling shroud.  

13. Close the system, reconnect the system to the electrical outlet, and turn on the system.  

14. Assign a new system and/or setup password.

To assign a new password using the System Setup program, see "Using the System Setup Program" in your User's Guide.

Back to Contents Page

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

NOTE: If you assign a new system and/or setup password with the jumper plug still removed, the system disables the new password(s) the next time it boots.

Back to Contents Page

  I/O Connectors Dell PowerEdge 800 Systems Installation and Troubleshooting Guide 

  Serial Connector

  Parallel Connector

  PS/2-Compatible Keyboard and Mouse Connectors

  Video Connector

  USB Connectors

  Integrated NIC Connectors

  Network Cable Requirements

I/O connectors are the gateways that the system uses to communicate with external devices, such as a keyboard, mouse, printer, or monitor. This section describes the various connectors on your system. If you reconfigure the hardware connected to the system, you may also need the pin number and signal information for these connectors. Figure B-1 illustrates the connectors on the system.

 Figure B-1. I/O Connectors

Table B-1 shows the icons used to label the connectors on the system.

 Table B-1. I/O Connector Icons

 Serial Connector

Serial connectors support devices such as external modems, printers, and mice that require serial data transmission. The serial connector is also used by the BMC to provide remote access to the system. The serial connector uses a 9-pin D-subminiature connector.

Icon

Connector

Serial connector

Parallel connector

Mouse connector

Keyboard connector

Video connector

USB connector

NIC connector

Serial Connector Autoconfiguration

The default designation of the integrated serial connector is COM1. When you add an expansion card containing a serial connector that has the same designation as the integrated connector, the system's autoconfiguration feature remaps (reassigns) the integrated serial connector to the next available designation. Both the new and the remapped COM connectors share the same IRQ setting. COM1 and COM3 share IRQ4, while COM2 and COM4 share IRQ3.

Before adding a card that remaps the COM connectors, check the documentation that came with the software to make sure that the software can accommodate the new COM connector designation.

Figure B-2 illustrates the pin numbers for the serial connector and Table B-2 defines the pin assignments for the connector.

 Figure B-2. Serial Connector Pin Numbers

 Table B-2. Serial Connector Pin Assignments 

 Parallel Connector

The integrated parallel connector, intended primarily for use by printers that require data in parallel format, uses a 25-pin D-subminiature connector on the system's back panel. The default designation of the system's parallel connector is LPT1. If you add an expansion card containing a parallel connector configured as LPT1 (IRQ7, I/O address 378h), use the System Setup program to remap the integrated parallel connector. See "Using the System Setup Program" in the User's Guide. Figure B-3 illustrates the pin numbers for the parallel connector and Table B-3 defines the pin assignments for the connector.

 Figure B-3. Parallel Connector Pin Numbers

 Table B-3. Parallel Connector Pin Assignments 

NOTE: If two COM connectors share an IRQ setting, you may not be able to use them both at the same time. In addition, if you install one or more expansion cards with serial connectors designated as COM1 and COM3, the integrated serial connector is disabled.

Pin

Signal

I/O

Definition

1 DCD I Data carrier detect

2 SIN I Serial input

3 SOUT O Serial output

4 DTR O Data terminal ready

5 GND N/A Signal ground

6 DSR I Data set ready

7 RTS O Request to send

8 CTS I Clear to send

9 RI I Ring indicator

Shell N/A N/A Chassis ground

Pin

Signal

I/O

Definition

1 STB# I/O Strobe

2 PD0 I/O Printer data bit 0

3 PD1 I/O Printer data bit 1

4 PD2 I/O Printer data bit 2

5 PD3 I/O Printer data bit 3

6 PD4 I/O Printer data bit 4

7 PD5 I/O Printer data bit 5

8 PD6 I/O Printer data bit 6

9 PD7 I/O Printer data bit 7

10 ACK# I Acknowledge

 PS/2-Compatible Keyboard and Mouse Connectors

The PS/2-compatible keyboard and mouse cables attach to 6-pin, miniature DIN connectors. Figure B-4 illustrates the pin numbers for these connectors and Table B-4 defines the pin assignments for these connectors.

 Figure B-4. PS/2-Compatible Keyboard and Mouse Connector Pin Numbers

 Table B-4. Keyboard and Mouse Connector Pin Assignments

 Video Connector

You can attach a VGA-compatible monitor to the system's integrated video controller using a 15-pin high-density D-subminiature connector on the system front or back panel. Figure B-5 illustrates the pin numbers for the video connector and Table B-5 defines the pin assignments for the connector.

 Figure B-5. Video Connector Pin Numbers

 Table B-5. Video Connector Pin Assignments

11 BUSY I Busy

12 PE I Paper end

13 SLCT I Select

14 AFD# O Automatic feed

15 ERR# I Error

16 INIT# O Initialize printer

17 SLIN# O Select in

1825 GND N/A Ground

Pin

Signal

I/O

Definition

1 KBDATA or MDATA I/O Keyboard data or mouse data

2 NC N/A No connection

3 GND N/A Signal ground

4 FVcc N/A Fused supply voltage

5 KBCLK or MCLK I/O Keyboard clock or mouse clock

6 NC N/A No connection

Shell N/A N/A Chassis ground

NOTE: Installing a video card automatically disables the system's integrated video controller.

Pin

Signal

I/O

Definition

1 RED O Red video

2 GREEN O Green video

3 BLUE O Blue video

4 NC N/A No connection

58, 10 GND N/A Signal ground

9 VCC N/A Vcc

11 NC N/A No connection

12 DDC data out O Monitor detect data

 USB Connectors

The system's USB connectors support USB-compliant peripherals such as keyboards, mice, and printers and may also support USB-compliant devices such as diskette drives and optical drives. Figure B-6 illustrates the pin numbers for the USB connector and Table B-6 defines the pin assignments for the connector.

 Figure B-6. USB Connector Pin Numbers

 Table B-6. USB Connector Pin Assignments

 Integrated NIC Connectors

Each of the system's integrated NICs function as a separate network expansion card while providing fast communication between servers and workstations. Figure B-7 illustrates the pin numbers for the NIC connector and Table B-7 defines the pin assignments for the connectors.

 Figure B-7. NIC Connector

 Table B-7. NIC Connector Pin Assignments

 Network Cable Requirements

The NIC supports a UTP Ethernet cable equipped with a standard RJ45-compatible plug.

Observe the following cabling restrictions.

13 HSYNC O Horizontal synchronization

14 VSYNC O Vertical synchronization

15 NC N/A No connection

NOTICE: Do not attach a USB device or a combination of USB devices that draw a maximum current of more than 500 mA per channel or +5 V. Attaching devices that exceed this threshold may cause the USB connectors to shut down. See the documentation that accompanied the USB devices for their maximum current ratings.

Pin

Signal

I/O

Definition

1 Vcc N/A Supply voltage

2 DATA I Data in

3 +DATA O Data out

4 GND N/A Signal ground

Pin

Signal

I/O

Definition

1 TD+ O Data out (+)

2 TD O Data out ()

3 RD+ I Data in (+)

4 NC N/A No connection

5 NC N/A No connection

6 RD I Data in ()

7 NC N/A No connection

8 NC N/A No connection

l  Use Category 5 or greater wiring and connectors.

l  Do not exceed a cable run length (from a workstation to a hub) of 100 m (328 ft).

For detailed guidelines on operation of a network, see "Systems Considerations of Multi-Segment Networks" in the IEEE 802.3 standard.

Back to Contents Page

NOTICE: To avoid line interference, voice and data lines must be in separate sheaths.

Back to Contents Page

  Introduction Dell PowerEdge 800 Systems Installation and Troubleshooting Guide 

  Other Documents You May Need

Your system includes the following service and upgrade features:

l  Embedded server management hardware, which monitors temperatures and voltages throughout the system

l  System diagnostics, which checks for hardware problems (if the system can boot)

System upgrade options are offered, including:

l  Microprocessors

l  Additional system memory

l  A variety of PCI, PCI-X, and PCIe expansion-card options (including SCSI and SATA RAID controller cards)

l  Optional remote access card for remote systems management

l  Tape backup units

l  Diskette drive

l  Additional SATA or SCSI hard drives

l  Optional SCSI backplane bay to support up to four front-access non-hot-plug SCSI hard drives (SCSI controller required) or hot-plug SCSI drives (optional SCSI RAID controller required)

 Other Documents You May Need

l  The Getting Started Guide provides an overview of initially setting up your system.

l  The User's Guide provides information about system features and technical specifications.

l  Systems management software documentation describes the features, requirements, installation, and basic operation of the software.

l  Operating system documentation describes how to install (if necessary), configure, and use the operating system software.

l  Documentation for any components you purchased separately provides information to configure and install these options.

l  Updates are sometimes included with the system to describe changes to the system, software, and/or documentation.

l  Release notes or readme files may be included to provide last-minute updates to the system or documentation or advanced technical reference material intended for experienced users or technicians.

Back to Contents Page

The Product Information Guide provides important safety and regulatory information. Warranty information may be included within this document or as a separate document.

NOTE: Always read the updates first because they often supersede information in other documents.

Back to Contents Page

  Indicators, Messages, and Codes Dell PowerEdge 800 Systems Installation and Troubleshooting Guide 

  Front-Panel Indicators and Features

  Back-Panel Features and Indicators

  SCSI Hard-Drive Indicator Codes

  Power Indicator Codes

  NIC Indicator Codes

  Diagnostics Indicator Codes

  System Messages

  System Beep Codes

  Warning Messages

  Diagnostics Messages

  Alert Messages

  Baseboard Management Controller Messages

The system, applications, and operating systems can identify problems and alert you to them. Any of the following can indicate when the system is not operating properly:

l  System indicators

l  System messages

l  Beep codes

l  Warning messages

l  Diagnostics messages

l  Alert messages

This section describes each type of message, lists the possible causes, and provides steps to resolve any problems indicated by a message. The system indicators and features are illustrated in this section.

 Front-Panel Indicators and Features

System Status Indicators

The system front panel incorporates blue and amber system status indicators. The blue indicator lights up when the system is operating correctly. The amber indicator lights up when the system needs attention due to a problem with power supplies, fans, system temperature, or hard drives.

Table 2-1 lists the system's indicator patterns. Different patterns are displayed as events occur in the system.

 Table 2-1. System Status Indicator Patterns

Figure 2-1 shows the controls, indicators, and connectors located behind the optional bezel on the system's front panel. Table 2-2 describes the front-panel features.

 Figure 2-1. Front-Panel Features and Indicators

Blue and Amber System Status Indicator

Description

Off Power is not available to the system.

Amber indicator is blinking. The system has detected an error. See "System Messages" and "Troubleshooting Your System" for more information.

Blue indicator is on. Amber indicator is off Power is on, and the system is operational.

 Table 2-2. Front-Panel Indicators, Buttons, and Connectors

 Back-Panel Features and Indicators

Figure 2-2 shows the controls, indicators, and connectors located on the system's back panel.

 Figure 2-2. Back-Panel Features and Indicators

Indicator, Button, or Connector

Description

Blue and amber system status indicator

The blue system status indicator lights during normal system operation. The amber system status indicator flashes when the system needs attention due to a problem with power supplies, fans, system temperature, or hard drives.

NOTE: If the system is connected to AC power and an error has been detected, the amber system status indicator flashes regardless of whether the system has been powered on.

Power button Turns system power off and on.

l  If you turn off the system using the power button and the system is running an ACPI-compliant operating system, the system can perform an orderly shutdown before power is turned off. If the power button is pressed for more than 4 seconds, the system power will turn off regardless of the current operating system state.

l  If the system is not running an ACPI-compliant operating system, power is turned off immediately after the power button is pressed.

The power button is enabled in the System Setup program. When disabled, the button can only turn the system power on. For more information, see "Using the System Setup Program" in your User's Guide, and the operating system's documentation.

Power-on indicator The power-on indicator lights when the system power is on. When the indicator is off, the system is off.

To exit from a power-saving state, briefly press the power button or click or move the mouse.

Hard-drive activity indicator

Flashes when data is being read from or written to the internal SATA hard drives that are connected to the integrated controller.

USB connectors Connects USB 2.0-compliant devices to the system.

 SCSI Hard-Drive Indicator Codes

If an optional SCSI RAID controller is installed in the system, two indicators on each of the hard-drive carriers provide information on the status of the SCSI hard drives. See Figure 2-3 and Table 2-3. The SCSI backplane firmware controls the drive power-on/fault indicator.

 Figure 2-3. SCSI Hard-Drive Indicators

Table 2-3 lists the drive indicator patterns. Different patterns are displayed as drive events occur in the system. For example, if a hard drive fails, the "drive failed" pattern appears. After the drive is selected for removal, the "drive being prepared for removal" pattern appears, followed by the "drive ready for insertion or removal" pattern. After the replacement drive is installed, the "drive being prepared for operation" pattern appears, followed by the "drive online" pattern.

 Table 2-3. Hard-Drive Indicator Patterns 

NOTE: If a RAID controller is not installed, only the "drive online" indicator pattern appears. The drive-activity indicator also blinks when the drive is being accessed.

Condition

Indicator Pattern

Identify drive The green power-on/fault indicator blinks four times per second.

Drive being prepared for removal The green power-on/fault indicator blinks two times per second.

Drive ready for insertion or removal Both drive indicators are off.

Drive being prepared for operation The green power-on/fault indicator is on.

 Power Indicator Codes

The power button on the front panel controls the power input to the system's power supplies. The power indicator can provide information on power status (see Figure 2-1). Table 2-4 lists the power button indicator codes.

 Table 2-4. Power Button Indicators

 NIC Indicator Codes

 Figure 2-4. NIC Indicators

 Table 2-5. NIC Indicators

 Diagnostics Indicator Codes

The four diagnostics indicators on the system front panel display error codes during system startup. Table 2-6 details the conditions associated with the diagnostic indicator codes.

 Table 2-6. Diagnostic Indicator Codes 

Drive predicted failure The power-on/fault indicator slowly blinks green, amber, and off.

Drive failed The amber power-on/fault indicator blinks four times per second.

Drive rebuilding The green power-on/fault indicator blinks slowly.

Drive online The green power-on/fault indicator is on.

Indicator

Function

On Indicates that power is supplied to the system and the system is operational.

Off Indicates that no power is supplied to the system.

Blinking Indicates that power is supplied to the system, but the system is in a standby state. For information on standby states, see your operating system documentation.

Link indicator

Activity indicator

Description

Off Off The NIC is not connected to the network or the NIC is disabled in the System Setup screen. See "Using the System Setup Program" in your User's Guide.

Green Off Indicates that the network adapter is connected to a valid link partner on the network, but data is not currently being sent or received.

Green Blinking amber Indicates that network data is being sent or received.

Code

Causes

Corrective Action

A possible processor failure has occurred.

See "Troubleshooting the Microprocessor" in "Troubleshooting Your System."

Memory failure. See "Troubleshooting System Memory" in "Troubleshooting Your System."

Possible expansion-card failure.

See "Troubleshooting Expansion Cards" in "Troubleshooting Your System."

Possible video card failure. See "Troubleshooting Expansion Cards" in "Troubleshooting Your System."

 System Messages

System messages appear on the screen during system boot to notify you of a possible problem with the system. Table 2-7 lists the system messages that can occur and the probable cause and corrective action for each message.

 Table 2-7. System Messages 

Diskette or hard-drive failure. Ensure that the diskette drive and hard drive(s) are properly connected. See

"Installing Drives" for information on the drive(s) installed in your system.

Possible USB failure. See "Troubleshooting a USB Device" in "Troubleshooting Your System."

No memory modules detected. See "Troubleshooting System Memory" in "Troubleshooting Your System."

System board failure. See "Getting Help."

Memory configuration error. See "Troubleshooting System Memory" in "Troubleshooting Your System."

Possible system board resource and/or system board hardware failure.

See "IRQ Assignment Conflicts" in "Finding Software Solutions." If the problem persists, see "Getting Help."

Possible expansion card failure. See "Troubleshooting Expansion Cards" in "Troubleshooting Your System."

Other failure. Ensure that the diskette drive, optical drive, and hard drive(s) are properly

connected. See "Troubleshooting Your System" for the appropriate drive(s) installed in your system.

If the problem persists, see "Getting Help."

The system is in a normal operating condition after POST.

Information only.

NOTE: If you receive a system message that is not listed in Table 2-7, check the documentation for the application that is running when the message appears or the operating system's documentation for an explanation of the message and recommended action.

Message

Causes

Corrective Actions

Amount of available memory limited to

256MB!

OS Install Mode is enabled in the System Setup program.

Disable OS Install Mode in the System Setup program. See "Using the System Setup Program" in your User's Guide.

Attempting to update Remote

Configuration. Please wait....

Remote Configuration is in progress.

Wait until the process is complete.

BIOS Update Attempt Failed BIOS remote update failed. Retry update.

Caution! NVRAM_CLR jumper is installed

on system board.

NVRAM_CLR jumper is installed.

Remove the NVRAM_CLR jumper. See Figure A-2 for the jumper location.

CD-ROM drive not found Improperly connected or missing optical drive.

If no optical drive is installed, disable the IDE controller. See "Using the System Setup Program" in your User's Guide.

If an optical drive is installed, see "Troubleshooting an Optical Drive" in "Troubleshooting Your System."

Decreasing available memory Faulty or improperly installed memory modules.

Ensure that all memory modules are properly installed. See "Troubleshooting System Memory" in "Troubleshooting Your System."

Diskette drive 0 seek failure Incorrect configuration settings in System Setup program.

Run the System Setup program to correct the settings. See "Using the System Setup Program" in your User's Guide.

Faulty or improperly installed diskette, loose diskette drive

Replace the diskette. Ensure that the diskette drive and optical drive cables are properly connected. See "Troubleshooting a Diskette Drive" and

or optical drive interface cable, or loose power cable.

"Troubleshooting an Optical Drive" in "Troubleshooting Your System."

Diskette read failure Faulty or improperly inserted diskette.

Replace the diskette.

Diskette subsystem reset failed Faulty diskette drive or optical drive controller.

Ensure that the diskette drive and optical drive cables are properly connected. See "Troubleshooting a Diskette Drive" and "Troubleshooting an Optical Drive" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

Drive not ready Diskette missing or improperly inserted in diskette drive.

Reinsert or replace the diskette.

Dual rank DIMMs are not supported in the

following memory sockets in this memory

configuration.

Invalid memory configuration. Correct the memory configuration. See "General Memory Module Installation Guidelines" in "Installing System Components."

Error: Incorrect memory configuration.

Ensure memory in slots DIMM1_A and

DIMM1_B, DIMM2_A and DIMM2_B match

identically in size, speed, and rank.

An unmatched pair of memory modules is installed.

Install a matched pair of memory modules, or remove the memory module in socket DIMM1_B. See "General Memory Module Installation Guidelines" in "Installing System Components."

Error: Remote Access Card initialization

failure.

Faulty or improperly installed RAC.

Ensure that the RAC is properly installed. See "Troubleshooting Expansion Cards" in "Troubleshooting Your System," or "Installing a RAC Card" in "Installing System Components."

Error 8602: Auxiliary device failure.

Verify that the keyboard and mouse are

securely attached to correct connectors.

Loose or improperly connected mouse or keyboard cable; faulty mouse or keyboard.

Replace the mouse. If the problem persists, replace the keyboard.

Gate A20 failure Faulty keyboard controller (faulty system board).

See "Getting Help."

General failure Operating system corrupted or improperly installed.

Reinstall the operating system.

IDE Primary drive 1 not found Improperly connected or missing optical drive or tape backup unit.

Ensure that the drive cables are properly connected. See "Troubleshooting Your System" for the appropriate drive installed in your system.

If no drive is installed, disable the IDE controller. See "Using the System Setup Program" in your User's Guide.

Keyboard controller failure Faulty keyboard controller (faulty system board).

See "Getting Help"

Keyboard data line failure

Keyboard failure

Keyboard stuck key failure

Loose or improperly connected keyboard cable; faulty keyboard; faulty keyboard controller.

Ensure that the keyboard is properly connected. If the problem persists, replace the keyboard. If the problem persists, see "Getting Help."

Keyboard fuse has failed. Keyboard fuse has failed. Replace the keyboard.

Faulty system board. See "Getting Help."

Manufacturing mode detected System is incorrectly configured.

After the message appears during system boot, press to turn off manufacturing mode.

Memory address line failure at address,

read value expecting value

Memory double word logic failure at

address, read value expecting value

Memory odd/even logic failure at start

address to end address

Memory write/read failure at address,

read value expecting value

Faulty or improperly installed memory modules, or faulty system board.

Ensure that all memory modules are properly installed. See "Troubleshooting System Memory" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

Memory tests terminated by keystroke The spacebar was pressed during POST to terminate the memory test.

Information only.

No boot device available Faulty or missing diskette drive, optical drive, or hard drive.

Check the Integrated Devices configuration settings in the System Setup program. See "Using the System Setup Program" in your User's Guide. Ensure that either SATA Controller, Diskette Controller, or IDE Controller is enabled. If the system is booting from a SCSI controller, ensure that the controller is properly connected. If the problem persists, replace the drive. See "Installing Drives."

No boot sector on hard-disk drive An operating system is not on the hard drive.

Check the hard-drive configuration settings in the System Setup program. See "Using the System Setup Program" in your User's Guide.

No timer tick interrupt Faulty system board. See "Getting Help."

Not a boot diskette Not a bootable diskette. Use a bootable diskette.

PCI BIOS failed to install Loose cables to expansion card(s); faulty or improperly installed expansion card.

Ensure that all appropriate cables are securely connected to the expansion cards. See "Troubleshooting Expansion Cards" in "Troubleshooting Your System."

PCIe Degraded Link Width Error: Embedded

Bus#nn/Dev#nn/Funcn

Expected Link Width is n

Faulty or improperly installed PCIe card.

Reseat the PCIe cards. See "Expansion Cards." If the problem persists, see "Getting Help."

 System Beep Codes

If an error that cannot be reported on the screen occurs during POST, the system may emit a series of beeps that identifies the problem.

Actual Link Width is n

PCIe Degraded Link Width Error: Slot n

Expected Link Width is n

Actual Link Width is n

Faulty or improperly installed PCIe card in the specified slot number.

Reseat the PCIe card in the specified slot number. See "Expansion Cards." If the problem persists, see "Getting Help."

PCIe Training Error: Embedded

Bus#nn/Dev#nn/Funcn

Faulty or improperly installed PCIe card.

Reseat the PCIe cards. See "Expansion Cards." If the problem persists, see "Getting Help."

PCIe Training Error: Slot n Faulty or improperly installed PCIe card in the specified slot number.

Reseat the PCIe card in the specified slot number. See "Expansion Cards." If the problem persists, see "Getting Help."

Plug & Play Configuration Error Error encountered in initializing PCI device; faulty system board.

Install the NVRAM_CLR jumper and reboot the system. See Figure A-2 for jumper location. Check for a BIOS update. If the problem persists, see "Troubleshooting Expansion Cards" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

Read fault

Requested sector not found

Faulty diskette, diskette drive, optical drive, or hard drive.

Replace the diskette. Ensure that the diskette, optical, and hard-drive cables are properly connected. See "Troubleshooting a Diskette Drive," "Troubleshooting an Optical Drive, "Troubleshooting SATA Hard Drives," or "Troubleshooting SCSI Hard Drives" in "Troubleshooting Your System" for the appropriate drive(s) installed in your system.

Remote Configuration update attempt

failed

System could not implement Remote Configuration request.

Retry Remote Configuration.

ROM bad checksum = address Faulty or improperly installed expansion card.

Remove and reseat the expansion cards. See "Troubleshooting Expansion Cards" in "Troubleshooting Your System."

SATA Port n hard disk not found SATA hard drive not connected to port n.

Ensure that the hard-drive cable is properly connected. See "Cabled SATA and SCSI Hard Drives" in "Installing Drives."

If a drive is not connected to port n, check that the SATA port is disabled in the System Setup program. See "Using the System Setup Program" in your User's Guide.

Sector not found

Seek error

Seek operation failed

Faulty diskette or hard drive. Replace the diskette. If the problem persists, see "Troubleshooting SATA Hard Drives" or "Troubleshooting SCSI Hard Drives" in "Troubleshooting Your System" for the appropriate drive installed in your system.

Shutdown failure Shutdown test failure. Ensure that all memory modules are properly installed. See "Troubleshooting System Memory" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

The amount of system memory has changed. Faulty memory module. See "Troubleshooting System Memory" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

Information only, if you have changed the memory configuration.

The amount of tested memory is below the

minimum system configuration. System

halted!

Invalid memory configuration or faulty memory module.

See "General Memory Module Installation Guidelines" in "Installing System Components."

See "Troubleshooting System Memory" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

Time-of-day clock stopped Faulty battery; faulty system board.

See "Troubleshooting the System Battery" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

Time-of-day not set - please run SETUP

program

Incorrect Time or Date settings; faulty system battery.

Check the Time and Date settings See "Using the System Setup Program" in your User's Guide. If the problem persists, see "Troubleshooting the System Battery" in "Troubleshooting Your System."

Timer chip counter 2 failed Faulty system board. See "Getting Help."

Unexpected interrupt in protected mode Faulty or improperly installed memory modules or faulty system board.

Ensure that all memory modules are properly installed. See "General Memory Module Installation Guidelines" in "Installing System Components." If the problem persists, see "Troubleshooting System Memory" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

Unsupported CPU stepping detected Processor is not supported by the system.

Check for a BIOS update using the Dell Support website at support.dell.com. If the problem persists, install a supported processor. See "Installing a Processor" in "Installing System Components."

Utility partition not available key was pressed during POST, but no utility partition exists on the boot hard drive.

Create a utility partition on the boot hard drive. See "Using the Dell OpenManage Server Assistant CD" in your User's Guide.

Warning! No microcode update loaded for

processor n

Unsupported processor. Update the BIOS firmware using the Dell Support website at support.dell.com.

Write fault

Write fault on selected drive

Faulty diskette, diskette drive, optical drive, hard drive.

Replace the diskette. Ensure that the diskette drive, optical drive, and hard- drive cables are properly connected. See "Troubleshooting a Diskette Drive," "Troubleshooting an Optical Drive," or "Troubleshooting SCSI Hard Drives" in "Troubleshooting Your System" for the appropriate drive(s) installed in your system.

If a beep code is emitted, write down the series of beeps and then look it up in Table 2-8. If you are unable to resolve the problem by looking up the meaning of the beep code, use system diagnostics to identify the possible cause. If you are still unable to resolve the problem, see "Getting Help."

 Table 2-8. System Beep Codes 

 Warning Messages

A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before you format a diskette, a message will warn you that you may lose all data on the diskette. Warning messages usually interrupt the task and require you to respond by typing y (yes) or n (no).

NOTE: If the system boots without a keyboard, mouse, or monitor attached, the system does not issue beep codes related to those peripherals.

Code

Cause

Corrective Action

1-1-2 CPU register test failure See "Troubleshooting the Microprocessor" in "Troubleshooting Your System."

1-1-3 CMOS write/read failure; faulty system board Faulty system board. See "Getting Help."

1-1-4 BIOS error Reflash the BIOS.

1-2-1 Programmable interval-timer failure; faulty system board

Faulty system board. See "Getting Help."

1-2-2 DMA initialization failure See "Troubleshooting System Memory" in "Troubleshooting Your System."

1-2-3 DMA page register write/read failure

1-3-1 Main-memory refresh verification failure

1-3-2 No memory installed

1-3-3 Chip or data line failure in the first 64 KB of main  memory

1-3-4 Odd/even logic failure in the first 64 KB of main  memory

1-4-1 Address line failure in the first 64 KB of main  memory

1-4-2 Parity failure in the first 64 KB of main memory

1-4-3 Fail-safe timer test failure

1-4-4 Software NMI port test failure

2-1-1 through 2-4-4

Bit failure in the first 64 KB of main memory

3-1-1 Slave DMA-register failure Faulty system board. See "Getting Help."

3-1-2 Master DMA-register failure

3-1-3 Master interrupt-mask register failure

3-1-4 Slave interrupt-mask register failure

3-2-2 Interrupt vector loading failure

3-2-4 Keyboard-controller test failure

3-3-1 CMOS failure

3-3-2 System configuration check failure

3-3-3 Keyboard controller not detected

3-3-4 Video memory test failure

3-4-1 Screen initialization failure

3-4-2 Screen-retrace test failure

3-4-3 Video ROM search failure

4-2-1 No timer tick Faulty system board. See "Getting Help."

  4-2-2 Shutdown test failure

4-2-3 Gate A20 failure

4-2-4 Unexpected interrupt in protected mode See "Troubleshooting Expansion Cards" in "Troubleshooting Your System."

4-3-1 Improperly installed or faulty memory modules See "Troubleshooting System Memory" in "Troubleshooting Your System."

4-3-2 No memory modules installed in the first memory module connector

Install a memory module in the first memory module connector. See "System Memory" in "Installing System Components."

4-3-3 Faulty system board Faulty system board. See "Getting Help."

4-3-4 Time-of-day clock stopped See "Troubleshooting System Memory" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

4-4-1 Super I/O chip failure; faulty system board Faulty system board. See "Getting Help."

4-4-4 Cache test failure; faulty processor See "Troubleshooting the Microprocessor" in "Troubleshooting Your System."

 Diagnostics Messages

When you run system diagnostics, an error message may result. Diagnostic error messages are not covered in this section. Record the message on a copy of the Diagnostics Checklist in "Getting Help," and then follow the instructions in that section for obtaining technical assistance.

 Alert Messages

Systems management software generates alert messages for your system. Alert messages include information, status, warning, and failure messages for drive, temperature, fan, and power conditions. For more information, see the systems management software documentation.

 Baseboard Management Controller Messages

The Baseboard Management Controller (BMC) enables you to configure, monitor, and recover systems remotely. BMC uses the system's serial port and integrated NIC1 to support fault logging and SNMP alerting.

For additional information on using BMC, see the documentation for the BMC and systems management applications.

Back to Contents Page

NOTE: Warning messages are generated by either the application or the operating system. For more information, see "Finding Software Solutions" and the documentation that accompanied the operating system or application.

NOTE: If the integrated network controller is used in an Ether Channel team or link aggregation team, the BMC management traffic will not function properly. For more information about network teaming, see the documentation for the network controller.

Back to Contents Page

  Finding Software Solutions Dell PowerEdge 800 Systems Installation and Troubleshooting Guide 

  Before You Begin

  Troubleshooting Errors and Conflicts

Software problems can be caused by:

l  Improper installation or configuration of an application

l  Application conflicts

l  Input errors

l  Interrupt assignment conflicts

Ensure that you are installing the software application according to the software manufacturer's recommended procedures. If a problem occurs after you install the software, you might need to troubleshoot your software application and your system.

See the documentation that accompanied the software or contact the software manufacturer for detailed troubleshooting information.

 Before You Begin

l  Scan the software media with antivirus software.

l  Read the software documentation before you run the installation utility.

l  Be prepared to respond to prompts from the installation utility.

The installation utility may require you to enter information about your system, such as how the operating system is configured, and the type of peripherals that are connected to the system. Have this information available before running the installation utility.

 Troubleshooting Errors and Conflicts

While configuring and running software, problems might occur that are caused by input errors, application conflicts, and/or IRQ assignment conflicts. The problems are sometimes indicated by error messages.

Error messages are generated by system hardware or software. "Indicators, Messages, and Codes" provides information about error messages that are hardware-based. If you receive an error message that is not listed, see your operating system or software program documentation for troubleshooting information.

Input Errors

Pressing a specific key or set of keys at the wrong time may produce unexpected results. See the documentation that came with the software application to ensure that the values or characters you are entering are valid.

Ensure that your operating system is configured properly to run the application. Remember that whenever you change the parameters of the operating system, the changes can conflict with an application's operating requirements. After you configure the operating system, you may need to reinstall or reconfigure a software application so that it can run properly in its new environment.

Application Conflicts

Some applications can leave unnecessary files or data behind after they are deleted from your system. Device drivers can also create application errors. If application errors occur, see your application device driver or operating system documentation for troubleshooting information.

IRQ Assignment Conflicts

Most PCI devices can share an IRQ, but they cannot use an IRQ simultaneously. To avoid this type of conflict, see the documentation for each PCI device for specific IRQ requirements.

 Table 3-1. IRQ Assignment Defaults 

NOTE: If all of the system diagnostic tests complete successfully, then the problem is most likely caused by the software and not the hardware.

IRQ Line

Assignment

IRQ0 System timer

IRQ1 Keyboard controller

Back to Contents Page

IRQ2 Interrupt controller 1 to enable IRQ8 through IRQ15

IRQ3 Available

IRQ4 Serial port 1 (COM1 and COM3)

IRQ5 Remote access controller

IRQ6 Diskette drive controller

IRQ7 Parallel port

IRQ8 Real-time clock

IRQ9 ACPI functions (used for power management)

IRQ10 Available

IRQ11 Available

IRQ12 PS/2 mouse port unless the mouse is disabled through the System Setup program

IRQ13 Math coprocessor

IRQ14 IDE optical drive controller

IRQ15 Available

Back to Contents Page

  Running the System Diagnostics Dell PowerEdge 800 Systems Installation and Troubleshooting Guide 

  Using Server Administrator Diagnostics

  System Diagnostics Features

  When to Use the System Diagnostics

  Running the System Diagnostics

  System Diagnostics Testing Options

  Using the Custom Test Options

If you experience a problem with your system, run the diagnostics before calling for technical assistance. The purpose of the diagnostics is to test your system's hardware without requiring additional equipment or risking data loss. If you are unable to fix the problem yourself, service and support personnel can use diagnostics test results to help you solve the problem.

 Using Server Administrator Diagnostics

To assess a system problem, first use the online Server Administrator diagnostics. If you are unable to identify the problem, then use the system diagnostics.

To access the online diagnostics, log into the Server Administrator home page, and then click the Diagnostics tab. For information about using diagnostics, see the online help. For additional information, see the Server Administrator User's Guide.

 System Diagnostics Features

The system diagnostics provides a series of menus and options for particular device groups or devices. The system diagnostics menus and options allow you to:

l  Run tests individually or collectively.

l  Control the sequence of tests.

l  Repeat tests.

l  Display, print, or save test results.

l  Temporarily suspend testing if an error is detected or terminate testing when a user-defined error limit is reached.

l  View help messages that briefly describe each test and its parameters.

l  View status messages that inform you if tests are completed successfully.

l  View error messages that inform you of problems encountered during testing.

 When to Use the System Diagnostics

If a major component or device in the system does not operate properly, component failure may be indicated. As long as the microprocessor and the system's input/output devices (monitor, keyboard, and diskette drive) are functioning, you can use the system diagnostics to help identify the problem.

 Running the System Diagnostics

The system diagnostics is run from the utility partition on your hard drive.

  1. As the system boots, press during POST.

2. From the utility partition main menu, select Run System Diagnostics, or select Run Memory Diagnostics if you are troubleshooting memory.

When you start the system diagnostics, a message is displayed stating that the diagnostics are initializing. Next, the Diagnostics menu appears. The menu allows you to run all or specific diagnostics tests or to exit the system diagnostics.

 System Diagnostics Testing Options

NOTICE: Use the system diagnostics to test only your system. Using this program with other systems may cause invalid results or error messages. In addition, use only the program that came with your system (or an updated version of that program).

NOTE: Before you read the rest of this section, start the system diagnostics so that you can see the utility on your screen.

Click the testing option in the Main Menu window. Table 4-1 provides a brief explanation of testing options.

 Table 4-1. System Diagnostics Testing Options 

 Using the Custom Test Options

When you select Custom Test in the Main Menu window, the Customize window appears and allows you to select the device(s) to be tested, select specific options for testing, and view the test results.

Selecting Devices for Testing

The left side of the Customize window listsdevices that can be tested. Devices are grouped by device type or by module, depending on the option you select. Click the (+) next to a device or module to view its components. Click (+) on any component to view the tests that are available. Clicking a device, rather than its components, selects all of the components of the device for testing.

Selecting Diagnostics Options

Use the Diagnostics Options area to select how you want to test a device. You can set the following options:

l  Non-Interactive Tests Only When checked, runs only tests that require no user intervention.

l  Quick Tests Only When checked, runs only the quick tests on the device. Extended tests will not run when you select this option.

l  Show Ending Timestamp When checked, time stamps the test log.

l  Test Iterations Selects the number of times the test is run.

l  Log output file pathname When checked, enables you to specify where the test log file is saved.

Viewing Information and Results

The tabs in the Customize window provide information about the test and the test results. The following tabs are available:

l  Results Displays the test that ran and the result.

l  Errors Displays any errors that occurred during the test.

l  Help Displays information about the currently selected device, component, or test.

l  Configuration Displays basic configuration information about the currently selected device.

l  Parameters If applicable, displays parameters that you can set for the test.

Back to Contents Page

Testing Option

Function

Express Test Performs a quick check of the system. This option runs device tests that do not require user interaction. Use this option to quickly identify the source of your problem.

Extended Test Performs a more thorough check of the system. This test can take an hour or longer.

Custom Test Tests a particular device.

Information Displays test results.

Back to Contents Page

  Troubleshooting Your System Dell PowerEdge 800 Systems Installation and Troubleshooting Guide 

 Safety FirstFor You and Your System

To perform certain procedures in this document, you must remove the system cover and work inside the system. While working inside the system, do not attempt to service the system except as explained in this guide and elsewhere in your system documentation.

 Start-Up Routine

Look and listen during the system's start-up routine for the indications described in Table 5-1.

 Table 5-1. Start-Up Routine Indications 

 Checking Basic Power Problems

  1. If the power indicator on the system front panel or power supply does not indicate that power is available to the system, ensure that the power cable is

securely connected to the power supply.  

2. If the system is connected to a PDU or UPS, turn the PDU or UPS off and then on.  

3. If the PDU or UPS is not receiving power, plug it into another electrical outlet. If it still is not receiving power, try another PDU or UPS.  

4. Reconnect the system to the electrical outlet and turn on the system.

If the system still is not working properly, see "Troubleshooting a Power Supply."

 Checking the Equipment

This section provides troubleshooting procedures for external devices attached to the system, such as the monitor, keyboard, or mouse. Before you perform

  Safety FirstFor You and Your System

  Start-Up Routine

  Checking Basic Power Problems

  Checking the Equipment

  Troubleshooting Basic I/O Functions

  Troubleshooting a NIC

  Responding to a Systems Management Software Alert Message 

  Opening the System

  Closing the System

  Inside the System

  Troubleshooting a Wet System

  Troubleshooting a Damaged System

  Troubleshooting the System Battery

  Troubleshooting a Power Supply

  Troubleshooting System Cooling Problems

  Troubleshooting System Memory

  Troubleshooting a Diskette Drive

  Troubleshooting an Optical Drive

  Troubleshooting a SCSI Tape Drive

  Troubleshooting SCSI Hard Drives

  Troubleshooting SATA Hard Drives

  Troubleshooting a RAID Controller Card

  Troubleshooting Expansion Cards

  Troubleshooting the Microprocessor

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

Look/listen for:

Action

An error message displayed on the monitor. See "System Messages" in "Indicators, Codes, and Messages."

A series of beeps emitted by the system. See "System Beep Codes" in "Indicators, Codes, and Messages."

Alert messages from the systems management software. See the systems management software documentation.

The monitor's power indicator. See "Troubleshooting the Video Subsystem."

The keyboard indicators. See "Troubleshooting the Keyboard."

The diskette drive activity indicator. See "Troubleshooting a Diskette Drive."

The optical drive activity indicator. See "Troubleshooting an Optical Drive."

The hard-drive activity indicator. See "Troubleshooting SCSI Hard Drives."

An unfamiliar constant scraping or grinding sound when you access a drive. See "Getting Help."

any of the procedures, see "Troubleshooting External Connections."

Troubleshooting External Connections

Loose or improperly connected cables are the most likely source of problems for the system, monitor, and other peripherals (such as a printer, keyboard, mouse, or other external device). Ensure that all external cables are securely attached to the external connectors on your system. See Figure 2-1 and Figure 2-2 for the front-panel and back-panel connectors on your system.

Troubleshooting the Video Subsystem

Problem

l  Monitor is not working properly.

l  Video memory is faulty.

Action

  1. Check the system and power connections to the monitor.

2. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

If the tests run successfully, the problem is not related to video hardware. See "Finding Software Solutions."

If the tests fail, see "Getting Help."

Troubleshooting the Keyboard

Problem

l  System message indicates a problem with the keyboard.

l  Keyboard is not functioning properly.

Action

  1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

2. Examine the keyboard and its cable for signs of damage.  

3. Swap the faulty keyboard with a working keyboard.

If the problem is resolved, replace the faulty keyboard.

  4. If the keyboard is a USB keyboard, enter the System Setup program and ensure that the USB ports are enabled. See "Using the System Setup Program"

in your User's Guide.

If the problem is not resolved, see "Getting Help."

Troubleshooting the Mouse

Problem

l  System message indicates a problem with the mouse.

l  Mouse is not functioning properly.

Action

  1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

If the test fails, continue to the next step.

  2. Examine the mouse and its cable for signs of damage.

If the mouse is not damaged, go to step 5.

If the mouse is damaged, continue to the next step.

  3. Swap the faulty mouse with a working mouse.

If the problem is resolved, replace the faulty mouse.

  4. If the mouse is a USB mouse, enter the System Setup program and ensure that the USB ports are enabled. See "Using the System Setup Program" in

your User's Guide.  

5. If the problem is not resolved, see "Getting Help."

 Troubleshooting Basic I/O Functions

Problem

l  Error message indicates a problem with the serial port.

l  Device connected to the serial port is not operating properly.

Action

  1. Enter the System Setup program and ensure that the serial port is enabled, and that console redirection is disabled. See "Using the System Setup

Program" in your User's Guide.  

2. If the problem is confined to a particular application, see the application documentation for specific port configuration requirements that the program may require.  

3. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

If the tests run successfully but the problem persists, see the appropriate procedure"Troubleshooting a Serial I/O Device" or "Troubleshooting a Non- USB Parallel Printer."

Troubleshooting a Serial I/O Device

Problem

l  Device connected to the serial port is not operating properly.

Action

  1. Turn off the system and any peripheral devices connected to the serial port.

2. Swap the serial interface cable with a working cable, and turn on the system and the serial device.

If the problem is resolved, replace the interface cable.

  3. Turn off the system and the serial device, and swap the device with a comparable device.

4. Turn on the system and the serial device.

If the problem is resolved, replace the serial device.

If the problem persists, see "Getting Help."

Troubleshooting a USB Device

Problem

l  System message indicates a problem with a USB device.

l  Device connected to a USB port is not operating properly.

Action

  1. Enter the System Setup program, and ensure that the USB ports are enabled. See "Using the System Setup Program" in your User's Guide.

2. Turn off the system and any USB devices.  

3. Disconnect the USB devices, and connect the malfunctioning device to another USB connector.  

4. Turn on the system and the reconnected device.

If the problem is resolved, the USB connector might be defective. See "Getting Help."

  5. If possible, swap the interface cable with a working cable.

If the problem is resolved, replace the interface cable.

  6. Turn off the system and the USB device, and swap the device with a comparable device.

7. Turn on the system and the USB device.

If the problem is resolved, replace the USB device.

If the problem persists, see "Getting Help."

Troubleshooting a Non-USB Parallel Printer

Problem

l  Parallel printer is not operating properly.

l  Parallel printer interface cable is faulty.

Action

  1. Turn off the system and the parallel printer.

2. Swap the parallel printer interface cable with a known working cable, and turn on the system and the printer.  

3. Attempt a print operation.  

4. If the print operation is successful, replace the interface cable (see "Getting Help").  

5. Run the printer's self-test.  

6. If the self-test fails, the printer is malfunctioning (see "Getting Help").

 Troubleshooting a NIC

Problem

l  NIC cannot communicate with network.

Action

  1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

2. Enter the System Setup program and confirm that the NICs are enabled. See "Using the System Setup Program" in your User's Guide.  

3. Check the appropriate indicator on the NIC connector. See "NIC Indicator Codes" in "Indicators, Messages, and Codes."

l  If the link indicator does not light, check all cable connections.

l  If the activity indicator does not light, the network driver files might be damaged or missing.

Remove and reinstall the drivers if applicable. See the NIC's documentation.

l  Use another connector on the switch or hub.

If you are using a NIC card instead of an integrated NIC, see the documentation for the NIC card.

  4. Ensure that the appropriate drivers are installed and the protocols are bound. See the NIC's documentation.

5. Ensure that the NICs, hubs, and switches on the network are all set to the same data transmission speed. See the network equipment documentation.  

6. Ensure that all network cables are of the proper type and do not exceed the maximum length. See "Network Cable Requirements" in your User's Guide.

 Responding to a Systems Management Software Alert Message 

Systems management software monitors critical system voltages and temperatures, fans, and hard drives in the system. Alert messages appear in the Alert Log window. For information about the Alert Log window, see the systems management software documentation.

 Opening the System

Removing the Bezel

You must remove the bezel to remove the system cover.

  1. Using the system key, unlock the bezel. See Figure 5-1.

2. Slide the bezel latch toward the right side of the system.  

3. Swing the top of the bezel away from the system, disengage the hooks at the bottom of the bezel, and lift the bezel away from the system.

 Figure 5-1. Removing the Bezel

Removing the Cover

To upgrade or troubleshoot the system, remove the system cover to gain access to internal components.

  1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the bezel. See "Removing the Bezel."  

3. Lay the system on its right side.  

4. Loosen the thumbscrew at the front of the system. See Figure 5-2.  

5. Slide the cover forward and grasp it at both ends.  

6. Lift the front edge of the cover 2.5 cm (1 inch), slide the cover toward the top of the system, and then lift the cover away from the system.

 Figure 5-2. Removing the Cover

 Closing the System

Replacing the Cover

  1. Ensure that all cables are connected, and fold cables out of the way.

2. Ensure that no tools or loose parts are left inside the system.  

3. Fit the cover on the side of the system, and slide the cover backward.  

4. Tighten the cover thumbscrew to secure the cover.

Installing the Bezel

To install the bezel, align the hooks at the bottom of the bezel, swing the top of the bezel toward the system, and press the bezel onto the system until it snaps into place. Using the system key, lock the bezel.

 Inside the System

In Figure 5-3, the bezel and system cover are removed to provide an interior view of the system.

 Figure 5-3. Inside the System

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

The system board holds the system's control circuitry and other electronic components. The processor and memory are installed directly on the system board. The system can accommodate up to five expansion cards.

The system supports up to four SCSI or SATA hard drives. The peripheral bays support an optional diskette drive and optical drive.

 Troubleshooting a Wet System

Problem

l  Liquid spilled on the system.

l  Excessive humidity.

Action

  1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2. Open the system. See "Opening the System."  

3. Remove all expansion cards installed in the system. See "Removing an Expansion Card" in "Installing System Components."  

4. Remove all memory modules installed in the system. See "Removing Memory Modules" in "Installing System Components."  

5. Remove the processor from the system. See "Removing the Processor" in "Installing System Components."  

6. Let the system dry thoroughly for at least 24 hours.  

7. Replace the processor, memory modules, and expansion cards. See "Installing a Processor," "Installing Memory Modules," and "Installing an Expansion Card" in "Installing System Components."  

8. Close the system. See "Closing the System."  

9. Reconnect the system to the electrical outlet, and turn on the system and peripherals.

If the system does not start properly, see "Getting Help."

  10. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running the System Diagnostics."

If the tests fail, see "Getting Help."

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

 Troubleshooting a Damaged System

Problem

l  System was dropped or damaged.

Action

  1. Open the system. See "Opening the System."

2. Ensure that the following components are properly installed:

l  Expansion cards

l  Memory modules

l  Processor

l  Power supplies

l  Fans

l  Hard drives

  3. Ensure that all cables are properly connected.

4. Close the system. See "Closing the System."  

5. Run the system board tests in the system diagnostics. See "Running the System Diagnostics."

If the tests fail, see "Getting Help."

 Troubleshooting the System Battery

Problem

l  System message indicates a problem with the battery.

l  System Setup program loses system configuration information.

l  System date and time do not remain current.

Action

  1. Re-enter the time and date through the System Setup program. See "Using the System Setup Program" in your User's Guide.

2. Turn off the system and disconnect it from the electrical outlet for at least one hour.  

3. Reconnect the system to the electrical outlet and turn on the system.  

4. Enter the System Setup program.

If the date and time are not correct in the System Setup program, replace the battery. See "System Battery" in "Installing System Components."

If the problem is not resolved by replacing the battery, see "Getting Help."

 Troubleshooting a Power Supply

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

NOTE: If the system is turned off for long periods of time (for weeks or months), the NVRAM may lose its system configuration information. This situation is caused by a defective battery.

NOTE: Some software may cause the system time to speed up or slow down. If the system seems to operate normally except for the time kept in the System Setup program, the problem may be caused by software rather than by a defective battery.

Problem

l  No power to the system.

l  Power indicator on the front panel does not light.

Action

  1. Run the appropriate online diagnostics test. See "Using Server Administrator Diagnostics" in "Running the System Diagnostics."

  2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

3. Open the system. See "Opening the System."  

4. Ensure that the power cables are properly connected to the power connectors on the system board and backplane (if installed). To identify the system board power connectors, see Figure A-3.  

5. Close the system. See "Closing the System."  

6. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem persists, see "Getting Help."

 Troubleshooting System Cooling Problems

Problem

l  A cooling fan is not operating properly.

l  System status indicator is amber.

l  Systems management software issues a fan-related error message.

Action

  1. Run the appropriate diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

2. Open the system. See "Opening the System."  

3. Locate the fan referenced by the systems management software or diagnostics.

See Figure A-3 for the relative location of each fan.

Ensure that the fan power cables are securely connected to the fan power connectors on the system board. See Figure A-3 for the location of each fan power connector.

  4. Check that cables are not blocking the airflow within the system.

5. Close the system. See "Closing the System."  

6. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.  

7. If the problem is not resolved, install a new fan. See "System Fans" in "Installing System Components."  

8. If the replacement fan does not operate, see "Getting Help."

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

 Troubleshooting System Memory

Problem

l  Faulty memory module.

l  Faulty system board.

l  System status indicator is amber.

l  System beep code indicates a memory problem.

l  Systems management software issues a memory-related message through the systems management software.

Action

Memory-related beep code during system startup.

  1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2. Open the system. See "Opening the System."  

3. Reseat the memory modules in their sockets. See "Installing Memory Modules" in "Installing System Components."  

4. Close the system. See "Closing the System."  

5. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If there is no memory-related beep code, the problem is resolved.

  6. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

a.  Open the system. See "Opening the System."

b.  Remove all memory modules from the system. See "Removing Memory Modules" in "Installing System Components."

c.  Replace one of the memory modules in socket DIMM1_B.

d.  Close the system. See "Closing the System."

e.  Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

f.  If there is no memory-related beep code, the memory module is not faulty.

If the beep code reoccurs, the memory module is faulty and should be replaced.

  7. Perform the following steps:

a.  Turn off the system and attached peripherals, and disconnect the system from its electrical outlet.

b.  Open the system. See "Opening the System."

c.  Repeat step c through step f in step 6 for each memory module installed.

8. If you have tested all the memory modules and the problem persists, or none of the memory modules passes, the system board is faulty. See "Getting Help."

The system starts up successfully but there are memory-related error messages.

  1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2. Open the system. See "Opening the System."  

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

  3. Ensure that the memory modules are populated correctly. See "General Memory Module Installation Guidelines" in "Installing System Components."

If the memory modules are populated correctly, continue to the next step.

  4. Reseat the memory modules in their sockets. See "Installing Memory Modules" in "Installing System Components."

5. Close the system. See "Closing the System."  

6. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If there is no memory-related error message, the problem is resolved.

If the problem persists, see "Getting Help."

There are memory-related error messages in the SEL.

  1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

2. Replace the memory module(s) identified by the diagnostics. See "Installing Memory Modules" in "Installing System Components."  

3. Restart the system. If there are still memory-related errors in the SEL, see "Getting Help."

 Troubleshooting a Diskette Drive

Problem

l  Error message indicates a problem with the optional diskette drive.

Action

  1. Enter the System Setup program and verify that the diskette controller is enabled and the diskette drive is configured correctly. See "Using the System

Setup Program" in your User's Guide.  

2. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."  

3. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  

4. Open the system. See "Opening the System."  

5. Ensure that the diskette drive interface cable is securely connected to the diskette drive and the system board. To identify the connector on the system board, see Figure A-3.  

6. Ensure that a power cable is securely connected to the drive.  

7. Close the system. See "Closing the System."  

8. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.  

9. Run the appropriate online diagnostic test to see whether the diskette drive works correctly.

If the tests fail, continue to the following step.

  10. Turn off the system and attached peripherals, and disconnect the system from its electrical outlet.

11. Open the system. See "Opening the System."  

12. Remove all expansion cards installed in the system. See "Removing an Expansion Card" in "Installing System Components."  

13. Close the system. See "Closing the System."  

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

  14. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

15. Run the appropriate online diagnostic test to see whether the diskette drive works correctly.

If the tests run successfully, an expansion card may be conflicting with the diskette drive logic, or an expansion card may be faulty. Continue to the next step.

If the tests fail, see "Getting Help."

  16. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

17. Open the system. See "Opening the System."  

18. Reinstall one of the expansion cards you removed in step 12. See "Installing an Expansion Card" in "Installing System Components."  

19. Close the system. See "Closing the System."  

20. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.  

21. Run the appropriate online diagnostic test to see whether the diskette drive works correctly.  

22. Repeat step 16 through step 21 until all expansion cards are reinstalled or one of the expansion cards causes the tests to fail.

If the problem is not resolved, see "Getting Help."

 Troubleshooting an Optical Drive

Problem

l  System cannot read data from a CD.

l  Optical drive indicator does not blink during boot.

Action

  1. Try using a different CD that you know works properly.

2. Enter the System Setup program and ensure that the drive's IDE controller is enabled. See "Using the System Setup Program" in your User's Guide.  

3. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."  

4. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  

5. Ensure that the optical drive interface cable is securely connected to the drive and the system board. To identify the connector on the system board, see Figure A-3.  

6. Ensure that a power cable is securely connected to the drive.  

7. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem is not resolved, see "Getting Help."

 Troubleshooting a SCSI Tape Drive

Problem

l  Defective tape drive.

l  Defective tape cartridge.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

l  Missing or corrupted tape-backup software or tape-drive device driver.

l  Defective SCSI controller card.

Action

  1. Run the System Setup program and ensure that the secondary SCSI channel is enabled and set to SCSI.

See "Using the System Setup Program" in your User's Guide.

  2. Remove the tape cartridge you were using when the problem occurred, and replace it with a tape cartridge that you know works.

3. Ensure that the SCSI device drivers for the tape drive are installed and are configured correctly.  

4. Reinstall the tape-backup software as instructed in the tape-backup software documentation.  

5. Ensure that the tape drive's interface cable is connected to the tape drive and SCSI controller card.  

6. Verify that the tape drive is configured for a unique SCSI ID number and that the tape drive is terminated or not terminated, based on the interface cable used to connect the drive.

See the documentation for the tape drive for instructions on selecting the SCSI ID number and enabling or disabling termination.

  7. Run the appropriate online diagnostics tests. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

8. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  

9. Open the system. See "Opening the System."  

10. Check that the SCSI controller card is firmly seated in its connector. See "Installing an Expansion Card" in "Installing System Components."  

11. Close the system. See "Closing the System."  

12. Reconnect the system to the electrical outlet, and turn on the system, including attached peripherals.  

13. If the problem is not resolved, see the documentation for the tape drive for additional troubleshooting instructions.  

14. If you cannot resolve the problem, see "Getting Help" for information on obtaining technical assistance.

 Troubleshooting SCSI Hard Drives

Troubleshooting a Hot-Plug or Front-Access (Non-Hot-Plug) SCSI Hard Drive

Problem

l  Device driver error.

l  Hard drive not recognized by the system.

Action

  1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

If the test fails, continue to the next step.

  2. Run the SCSI controllers test and the hard-drive tests in the system diagnostics. See "Running the System Diagnostics."

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

NOTICE: This procedure can destroy data stored on the hard drive. Before you continue, back up all files on the hard drive.

For information about testing the controller, see the controller's documentation.

If the tests fail, continue to the next step.

  3. If the SCSI hard drives are configured in a RAID array, restart the system and enter the RAID configuration utility.

  4. Ensure that the primary SCSI channel is enabled, and restart the system.

5. Verify that the device drivers are installed and configured correctly. See the operating system documentation.  

6. Remove the bezel. See "Removing the Bezel."  

7. Remove the hard drive:

 If your hard drive is not configured in a RAID array, shut down the system, remove the hard drive and install it in another drive bay. See "Front- Access SCSI Hard Drives (Non-Hot-Plug)" in "Installing Drives."

 If your hard drive is configured in a RAID array with four hard drives, install a new hard drive. See "Hot-Plug SCSI Hard Drives" in "Installing Drives."

 If your hard drive is configured in a RAID array with up to three hard drives, remove the hard drive and install the drive in an empty drive bay. See "Hot-Plug SCSI Hard Drives" in "Installing Drives."

  8. Install the bezel. See "Installing the Bezel."

9. If the system recognizes the hard drive, reinstall the hard drive in the original bay. See "Hot- Plug SCSI Hard Drives" or "Front-Access SCSI Hard Drives (Non-Hot-Plug)" in "Installing Drives."

If the hard drive functions properly in the original bay, the drive carrier could have intermittent problems. Replace the drive carrier. See "Hot-Plug SCSI Hard Drives" or "Front-Access SCSI Hard Drives (Non-Hot-Plug)" in "Installing Drives."

If the problem persists, the SCSI backplane board has a defective connector. See "Getting Help."

  10. Check the SCSI cable connections inside the system:

a.  Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

b.  Open the system. See "Opening the System."

c.  Lay the system on its right side.

d.  Remove the cover. See "Removing the Cover."

e.  Verify that the SCSI cable is securely connected to the controller card and the SCSI backplane.

f.  Replace the cover. See "Replacing the Cover."

g.  Stand the system upright.

h.  Install the bezel. See "Installing the Bezel."

11. Format and partition the hard drive. See the operating system documentation.  

12. If possible, restore the files to the drive.

If the problem persists, see "Getting Help."

Troubleshooting a Cabled SCSI Hard Drive

Problem

l  Device driver error.

l  Hard drive not recognized by the system.

NOTE: To enter the utility, press ,

, or , depending on the utility. See the documentation supplied with the controller for information about the configuration utility.

NOTICE: Do not swap the hard drives in a four hard-drive RAID configuration. Doing so may corrupt the data on both hard drives.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

Action

1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

If the test fails, continue to the next step.

2. Run the SCSI controllers test and the hard-drive tests in the system diagnostics. See "Running the System Diagnostics."

For information about testing the controller, see the SCSI or RAID controller card's documentation.

If the tests fail, continue to the next step.

3. Restart the system and enter the configuration utility.

4. Ensure that the primary SCSI channel is enabled, and restart the system. See the controller card's documentation.

5. Ensure that the required device drivers are installed and configured correctly. See the Dell OpenManage Server Assistant CD.

6. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

7. Open the system. See "Opening the System."

8. Lay the system on its right side.

9. Ensure that the hard-drive interface cable is properly connected between the drive and the controller card. See the controller card's documentation.

10. If the hard drive is the boot drive, ensure that the drive is configured and connected properly. See "Configuring the Boot Drive" in "Installing Drives."

11. Ensure that a power cable is properly connected to the drive.

12. Ensure that the controller card is installed correctly.

13. Ensure that the hard drive is configured with a unique SCSI ID number and that the drive is terminated or not terminated as appropriate. See the documentation for the hard drive.

14. Install the cover. See "Replacing the Cover."

15. Stand the system upright.

16. Install the bezel. See "Installing the Bezel."

17. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

18. Format and partition the hard drive. See the operating system documentation.

19. If possible, restore the files to the drive.

If the problem persists, see "Getting Help."

Troubleshooting SATA Hard Drives

Troubleshooting a SATA Hard Drive

Problem

NOTICE: This procedure can destroy data stored on the hard drive. Before you continue, back up all files on the hard drive.

NOTE: To enter the utility, press ,
, or , depending on the utility. See the documentation supplied with the controller for information about the configuration utility.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

l Faulty hard drive.

l Damaged or improperly connected hard-drive cables.

Action

1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running the System Diagnostics."

2. Enter the System Setup program and verify that the system is configured correctly. See "Using the System Setup Program" in your User's Guide.

3. Remove the bezel. See "Removing the Bezel."

4. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

5. Open the system. See "Opening the System."

6. Ensure that the hard-drive interface cable is properly connected between the drive and the system board.

To identify system board connectors, see Figure A-3.

7. If the hard drive is the boot drive, ensure that the drive is configured and connected properly. See "Configuring the Boot Drive" in "Installing Drives."

8. Ensure that the power cable is properly connected to the drive.

9. Install the cover. See "Replacing the Cover."

10. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

11. Format and partition the hard drive. See the operating system documentation.

12. If possible, restore the files to the drive.

If the problem persists, see "Getting Help."

Troubleshooting a SATA Hard Drive in a RAID Configuration

Problem

l Device driver error.

l Damaged or improperly connected hard-drive cables.

Action

1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running the System Diagnostics."

2. Restart your system and enter the RAID configuration utility. See the RAID controller documentation.

3. Ensure that the required device drivers are installed and are configured correctly. See the Dell OpenManage Server Assistant CD and the RAID controller's documentation.

4. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

NOTICE: This troubleshooting procedure can destroy data stored on the hard drive. Before you proceed, back up all files on the hard drive.

NOTE: If the hard drive is used in a RAID configuration, see "Troubleshooting a SATA Hard Drive in a RAID Configuration."

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

NOTICE: This troubleshooting procedure can destroy data stored on the hard drive. Before you proceed, back up all files on the hard drive.

5. Open the system. See "Opening the System."

6. Ensure that the hard-drive interface cable is properly connected to the drive and to the controller card. See the documentation that accompanied the controller card.

7. If the hard drive is the boot drive, ensure that the drive is configured and connected properly. See "Configuring the Boot Drive" in "Installing Drives."

8. Ensure that the power cable is properly connected to the drive.

9. Close the system. See "Closing the System."

10. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem persists, continue to the next step.

11. Format and partition the hard drive. See the operating system documentation.

12. If possible, restore the files to the drive.

If the problem persists, see "Getting Help."

Troubleshooting a RAID Controller Card

Problem

l Error message indicates a RAID controller problem.

l RAID controller performs incorrectly or not at all.

Action

1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running the System Diagnostics."

2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

3. Open the system. See "Opening the System."

4. Ensure that the controller card is firmly seated in its connector. See "Installing an Expansion Card" in "Installing System Components."

5. Ensure that the appropriate cables are firmly connected to their corresponding connectors on the controller card and SCSI backplane.

6. Close the system. See "Closing the System."

7. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem persists, see the RAID controller's documentation for more information on troubleshooting.

Troubleshooting Expansion Cards

Problem

l Error message indicates a problem with an expansion card.

l Expansion card performs incorrectly or not at all.

NOTE: When troubleshooting a RAID controller card, also see the documentation for your operating system and the RAID controller.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

NOTE: When troubleshooting an expansion card, see the documentation for your operating system and the expansion card.

Action

1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

3. Open the system. See "Opening the System."

4. Ensure that each expansion card is firmly seated in its connector. See "Installing an Expansion Card" in "Installing System Components."

5. Close the system. See "Closing the System."

6. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem persists, go to the next step.

7. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

8. Open the system. See "Opening the System."

9. Remove all expansion cards installed in the system. See "Removing an Expansion Card" in "Installing System Components."

10. Close the system. See "Closing the System."

11. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

12. Run the appropriate online diagnostic test.

If the tests fail, see "Getting Help."

13. For each expansion card you removed in step 9, perform the following steps:

a. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

b. Open the system. See "Opening the System."

c. Reinstall one of the expansion cards. See "Installing an Expansion Card."

d. Close the system. See "Closing the System."

e. Run the appropriate diagnostic test.

If the tests fail, see "Getting Help."

Troubleshooting the Microprocessor

Problem

l Error message indicates a processor problem.

Action

1. Run the appropriate online diagnostics test. See "Using Server Administrator Diagnostics" in "Running the System Diagnostics."

2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

3. Open the system. See "Opening the System."

4. Ensure that the processor and heat sink are properly installed. See "Processor" in "Installing System Components."

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

5. Close the system. See "Closing the System."

6. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

7. Run the appropriate online diagnostic test.

If the tests fail or the problem persists, continue to the next step.

8. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

9. Open the system. See "Opening the System."

10. Replace the processor with another processor of the same capacity. See "Processor" in "Installing System Components."

11. Close the system. See "Closing the System."

12. Run the appropriate online diagnostic test.

If the tests complete successfully, replace the processor. See "Getting Help."

If the problem persists, see "Getting Help."

Back to Contents Page

Back to Contents Page

Installing System Components Dell PowerEdge 800 Systems Installation and Troubleshooting Guide

Cooling Shroud

System Fans

Power Supply

Expansion Cards

System Memory

Processor

Installing a RAC Card

System Battery

This section describes how to install the following system components:

l Cooling shroud

l System fans

l Power supply

l Memory modules

l Processor

l Expansion cards

l System battery

Cooling Shroud

Removing the Cooling Shroud

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

3. Lay the system on its right side.

4. Remove the cover. See "Removing the Cover" in "Troubleshooting Your System."

5. Disconnect the power cables and hard-drive interface cable connectors from the SCSI backplane (if applicable) or hard drives.

6. Press the shroud release tab on the back panel toward the power supply. See Figure 6-1.

7. Lift the cooling shroud out of the system. See Figure 6-1.

Figure 6-1. Removing the Cooling Shroud

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

Installing the Cooling Shroud

1. Ensure that no tools or loose parts are left inside the system.

2. Align the anchor tabs on the cooling shroud with the notches in the system chassis.

3. Reposition the SCSI cable and power cables so they do not obstruct the memory modules and interfere with installing the cooling shroud.

4. Gently lower the cooling shroud until the shroud release tab on the back panel snaps into place.

5. Reconnect the power cable(s) to the SCSI backplane (if applicable) or the hard drive(s).

System Fans

The system includes the following cooling fans:

l Front system fan

l Back system fan

Removing the Front System Fan

Figure 6-2 illustrates the front system fan inside the system and the fan cable routing hole in the expansion-card guide bracket.

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

3. Lay the system on its right side.

4. Remove the cover. See "Removing the Cover" in "Troubleshooting Your System."

5. Disconnect the fan power cable from the FRONT_FAN connector on the system board. See Figure 6-2.

Figure 6-2. Front System Fan Power Cable

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

6. Compress the two release tabs on the top of the fan assembly and lift the fan assembly away from the system. See Figure 6-3.

Figure 6-3. Removing and Replacing the Front System Fan

Installing the Front System Fan

1. Insert the fan power cable through the routing hole in the expansion-card guide bracket. See Figure 6-2.

2. Align the fan assembly with the slots in the chassis and lower the assembly into the chassis. See Figure 6-3.

3. Pull the fan cable through the routing hole in the expansion-card guide bracket. See Figure 6-2.

4. Connect the fan cable connector to the FRONT_FAN connector on the system board.

5. Install the cover. See "Replacing the Cover" in "Troubleshooting Your System."

6. Stand the system upright.

7. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."

8. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Removing the Back System Fan

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

3. Lay the system on its right side.

4. Remove the cover. See "Removing the Cover" in "Troubleshooting Your System."

5. Remove the cooling shroud. See "Removing the Cooling Shroud."

6. Disconnect the fan cable from the BACK_FAN connector on the system board. To identify system board connectors, see Figure A-3.

7. Pull the release tab on the fan assembly away from the back panel and slide the fan assembly about 0.63 cm (0.25 inch) toward the expansion-card slots. See Figure 6-4.

8. Pull the fan assembly forward and lift the assembly out of the system. See Figure 6-4.

Figure 6-4. Removing the Back System Fan

Installing the Back System Fan

1. Align the tabs on the fan bracket with the mounting holes in the back panel and slide the fan assembly toward the power supply about 0.6 cm (0.25

inch) until the fan bracket release tab snaps into place. See Figure 6-4.

2. Connect the fan cable to the BACK_FAN connector on the system board.

To identify system board connectors, see Figure A-3.

3. Install the cooling shroud. See "Installing the Cooling Shroud."

4. Install the cover. See "Replacing the Cover" in "Troubleshooting Your System."

5. Stand the system upright.

6. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."

7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

Power Supply

Removing the Power Supply

1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

3. Lay the system on its right side.

4. Remove the cover. See "Removing the Cover" in "Troubleshooting Your System."

5. Disconnect the DC power cables from the following components:

l POWER CONN connector on the backplane board (if applicable)

l PWR CONN and 12V connectors on the system board

l Hard drives or SCSI backplane board

l Diskette drive (if applicable)

l Optical drive (if applicable)

l Tape backup drive (if applicable)

6. Remove the cooling shroud. See "Removing the Cooling Shroud."

7. Remove the four screws securing the power supply to the back panel. See Figure 6-5.

Figure 6-5. Removing the Power Supply

8. Slide the power supply toward the front of the system, and then lift the power supply up and out of the system.

Replacing the Power Supply

1. Lower the power supply into the system and align the mounting holes with the holes on the back panel.

2. Install the four screws securing the power supply to the back panel.

CAUTION: See the Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

3. Install the cooling shroud. See "Installing the Cooling Shroud."

4. Connect the DC power cables to the following components:

l POWER CONN connector on the backplane board (if applicable)

l PWR CONN and 12V connectors on the system board

l Hard drives or SCSI backplane.

l Diskette drive (if applicable)

l Optical drive (if applicable)

l Tape backup drive (if applicable)

5. Install the cover. See "Replacing the Cover" in "Troubleshooting Your System."

6. Stand the system upright.

7. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."

8. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Expansion Cards

Your system supports up to five full-length expansion cards, installed in connectors on a riser card. The expansion slots are configured as follows:

Slots 1 and 2 are x1 lane-width PCI-Express expansion slots.

Slots 3 and 4 are 3.3-V, 64-bit, 100-MHz PCI-X expansion slots. 133-MHz cards installed in these slots will run at 100 MHz.

Slot 5 is a 5-V, 32-bit, 33-MHz legacy PCI expansion slot.

Figure 6-6 shows the relative locations of the expansion-card slots.

Figure 6-6. Expansion Slots

Installing an Expansion Card

1. Unpack the expansion card, and prepare it for installation.

For instructions, see the documentation that accompanied the card.

2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

3. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

4. Lay the system on its right side.

NOTICE: If you install a RAC card, it must be installed in PCI slot SLOT_5.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

5. Remove the cover. See "Removing the Cover" in "Troubleshooting Your System."

6. Remove the filler bracket from the expansion slot.

7. Install the expansion card. See Figure 6-7.

a. Position the expansion card so that the card-edge connector aligns with the expansion- card connector on the system board.

b. Insert the card-edge connector firmly into the expansion-card connector until the card is fully seated.

c. Install the screw that secures the expansion-card bracket to the back panel.

8. Connect any cables that should be attached to the card.

See the documentation that accompanied the card for information about its cable connections.

9. Install the cover. See "Replacing the Cover" in "Troubleshooting Your System."

10. Stand the system upright.

11. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."

12. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

13. Install any device drivers required for the card as described in the documentation for the card.

Figure 6-7. Removing and Installing an Expansion Card

Removing an Expansion Card

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

3. Lay the system on its right side.

4. Remove the cover. See "Removing the Cover" in "Troubleshooting Your System."

5. Disconnect any cables attached to the card.

6. Remove the expansion card (see Figure 6-7):

a. Remove the screw that secures the expansion-card bracket to the back panel.

b. Grasp the expansion card by its top corners, and carefully remove it from the expansion- card connector.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

NOTICE: You must install a filler bracket over an empty expansion slot to maintain Federal Communications Commission (FCC) certification of the system. The brackets also help keep dust and dirt out of the system and aid in proper cooling and airflow inside the system.

7. If you are removing the card permanently, install a metal filler bracket over the empty expansion slot opening and close the expansion-card latch.

8. Install the cover. See "Replacing the Cover" in "Troubleshooting Your System."

9. Stand the system upright.

10. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."

11. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

System Memory

You can upgrade your system memory to a maximum of 4 GB by installing combinations of 256-MB, 512-MB, or 1-GB 2-way unbuffered ECC DDR 2 400/533 memory modules. The system memory is located on the system board adjacent to the power supply bays. See Figure A-3. The memory module sockets are arranged in two banks on two channels (A and B). The memory module banks are identified as follows:

l Bank 1: DIMM1_A and DIMM1_B

l Bank 2: DIMM2_A and DIMM2_B

General Memory Module Installation Guidelines

l If only one memory module is installed, it must be installed in socket DIMM1_A.

l If two or more memory modules are installed, they must be installed in pairs of matched memory size, speed, and technology.

Table 6-1 shows examples of different memory configurations.

Table 6-1. Sample Memory Configurations

Installing Memory Modules

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

3. Lay the system on its right side.

4. Remove the cover. See "Removing the Cover" in "Troubleshooting Your System."

5. Remove the cooling shroud. See "Removing the Cooling Shroud."

6. Locate the memory module sockets. See Figure A-3.

7. Press the ejectors on the memory module socket down and out, as shown in Figure 6-8, to allow the memory module to be inserted into the socket.

Figure 6-8. Installing and Removing a Memory Module

Total Memory

DIMM1_A

DIMM2_A

DIMM1_B

DIMM2_B

Memory Mode

256 MB 256 MB none none none Single channel

512 MB 256 MB none 256 MB none Dual channel, interleaved

512 MB 512 MB none none none Single channel

1 GB 256 MB 256 MB 256 MB 256 MB Dual channel, interleaved

1 GB 512 MB none 512 MB none Dual channel, interleaved

1 GB 1 GB none none none Single channel

1.5 GB 512 MB 256 MB 512 MB 256 MB Dual channel, interleaved

2 GB 512 MB 512 MB 512 MB 512 MB Dual channel, interleaved

2 GB 1 GB none 1 GB none Dual channel, interleaved

3 GB 1 GB 512 MB 1 GB 512 MB Dual channel, interleaved

4 GB 1 GB 1 GB 1 GB 1 GB Dual channel, interleaved

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

8. Align the memory module's edge connector with the alignment key on the memory module socket, and insert the memory module in the socket.

9. Press down on the memory module with your thumbs while pulling up on the ejectors with your index fingers to lock the memory module into the socket.

When the memory module is properly seated in the socket, the ejectors on the memory module socket align with the ejectors on the other sockets that have memory modules installed.

10. Repeat step 6 through step 9 of this procedure to install the remaining memory modules. See Table 6-1 for sample memory configurations.

11. Install the cooling shroud. See "Installing the Cooling Shroud."

12. Install the cover. See "Replacing the Cover" in "Troubleshooting Your System."

13. Stand the system upright.

14. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."

15. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

16. (Optional) Press to enter the System Setup program, and check the System Memory setting on the main System Setup screen.

The system should have already changed the value to reflect the newly installed memory.

17. If the value is incorrect, one or more of the memory modules may not be installed properly. Repeat step 1 through step 16 of this procedure, checking to

ensure that the memory modules are firmly seated in their sockets.

18. Run the system memory test in the system diagnostics. See "Running the System Diagnostics."

Removing Memory Modules

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

3. Lay the system on its right side.

4. Remove the cover. See "Removing the Cover" in "Troubleshooting Your System."

5. Remove the cooling shroud. See "Removing the Cooling Shroud."

6. Locate the memory module sockets. See Figure A-3.

7. Press down and out on the ejectors on each end of the socket until the memory module pops out of the socket. See Figure 6-8.

8. Install the cooling shroud. See "Installing the Cooling Shroud."

NOTE: The memory module socket has an alignment key that allows you to install the memory module in the socket in only one way.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

9. Install the cover. See "Replacing the Cover" in "Troubleshooting Your System."

10. Stand the system upright.

11. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."

Processor

You can upgrade the system processor to take advantage of future options in speed and functionality.

The following items are included in the processor upgrade kit:

l Processor

l Heat sink

Removing the Processor

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

3. Lay the system on its right side.

4. Remove the cover. See "Removing the Cover" in "Troubleshooting Your System."

5. Remove the cooling shroud. See "Removing the Cooling Shroud."

6. Remove the heat sink. See Figure 6-9.

a. Open one securing clip by pressing the end of the clip down and away from the retention until it clears the securing tab on the retention module,

and then lift the clip up.

b. Repeat step a for the remaining securing clip.

c. Rotate the heat sink slightly and then lift the heat sink off the processor. Do not pry the processor off the heat sink.

Figure 6-9. Removing the Heat Sink

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

NOTICE: Never remove the heat sink from a processor unless you intend to remove the processor. The heat sink is necessary to maintain proper thermal conditions.

7. Press down on the processor socket release lever, then pull the release lever upward to the fully open position. See Figure 6-10.

8. Open the processor cover. See Figure 6-10.

9. Lift the processor vertically out of the socket. Leave the processor cover and release lever in the open position so that the socket is ready for the new processor. See Figure 6-10.

Figure 6-10. Replacing the Processor

Installing a Processor

1. Unpack the new processor and heat sink.

2. Ensure that the processor socket release lever is in the fully open position.

3. Align the pin 1 corners of the processor and socket. See Figure 6-10.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

NOTICE: You must position the processor correctly in the socket to avoid damaging the processor and the system board when you turn on the system. Be careful not to touch or bend the pins on the socket.

4. Set the processor lightly in the socket and ensure that the processor is level in the socket. When the processor is positioned correctly, press it gently to seat it in the socket.

5. Close the processor cover.

6. Rotate the release lever back down until it snaps into place, securing the processor cover.

7. Remove the thermal grease protective cover from the new heat sink.

If you did not receive a new heat sink with the processor, see "Getting Help."

8. Lower the heat sink onto the processor. See Figure 6-9.

9. Secure the heat sink to the retention module.

a. Gently press down on the heat sink and then press one securing clip to secure it.

b. Repeat step a for the remaining securing clip.

10. Ensure that the back fan connector is connected to the BACK_FAN connector on the system board. See Figure A-3.

11. Install the cooling shroud. See "Installing the Cooling Shroud."

12. Install the cover. See "Replacing the Cover" in "Troubleshooting Your System."

13. Stand the system upright.

14. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."

15. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

16. Enter the System Setup program, and ensure that the processor options match the new system configuration. See "Using the System Setup Program" in your User's Guide.

As the system boots, it detects the presence of the new processor and automatically changes the system configuration information in the System Setup program. A message similar to the following appears:

One 2.3 GHz Processor, Processor Bus: 533 MHz, L2 cache 256 KB Advanced

17. Confirm that the top line of the system data area in the System Setup program correctly identifies the installed processor. See "Using the System Setup

Program" in your User's Guide.

18. Exit the System Setup program.

19. Ensure that your system is running the latest BIOS version.

You can download the latest BIOS version from the Dell Support website located at support.dell.com

20. Run the system diagnostics to verify that the new processor is operating correctly.

See "Running the System Diagnostics" for information on running the diagnostics and troubleshooting any problems that may occur.

Installing a RAC Card

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

3. Lay the system on its right side.

4. Remove the cover. See "Removing the Cover" in "Troubleshooting Your System."

5. Install the RAC card in PCI expansion slot SLOT_5.

NOTICE: Do not operate the system without the heat sink installed. The heat sink is required to maintain proper thermal conditions.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

See "Installing an Expansion Card" for information on installing the card.

6. Connect the cable from the RAC card to connector RAC_CONN on the system board. See Figure A-3.

7. Install the cover. See "Replacing the Cover" in "Troubleshooting Your System."

8. Stand the system upright.

9. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."

10. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

11. Enter the System Setup program and verify that the setting for the RAC card has changed to reflect the presence of the card. See "Using the System Setup Program" in your User's Guide.

See the RAC card documentation for information on configuring and using the RAC card.

System Battery

Replacing the System Battery

1. Enter the System Setup program and record the option settings on the System Setup screens.

See "Using the System Setup Program" in the User's Guide.

2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

3. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

4. Lay the system on its right side.

5. Remove the cover. See "Removing the Cover" in "Troubleshooting Your System."

6. Remove the system battery. See Figure A-3 for the battery socket location on the system board.

a. Pull the latch away from the battery. See Figure 6-11

b. Lift the battery out of the battery socket.

Figure 6-11. Removing the System Battery

7. To install the new system battery, hold the battery with the side labeled "+" facing up, and then press the battery straight down into the battery socket

until the latch snaps into place over the edge of the battery. See Figure 6-11.

8. Install the cover. See "Replacing the Cover" in "Troubleshooting Your System."

9. Stand the system upright.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

NOTICE: You must install the new system battery with the side labeled "+" facing up. See Figure 6-11.

10. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."

11. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

12. Enter the System Setup program to confirm that the battery operates properly.

13. From the main screen, select System Time to enter the correct time and date.

14. Re-enter any system configuration information that is no longer displayed on the System Setup screens, and then exit the System Setup program.

15. To test the newly installed battery, see "Troubleshooting the System Battery" in "Troubleshooting Your System."

Back to Contents Page

Back to Contents Page

Installing Drives Dell PowerEdge 800 Systems Installation and Troubleshooting Guide

Connecting Drives

Front-Panel Drive Inserts

Diskette Drive

5.25-Inch Drives

Hard Drives

Cabled SATA and SCSI Hard Drives

Front-Access SCSI Hard Drives (Non-Hot-Plug)

Hot-Plug SCSI Hard Drives

Installing the Optional SCSI Backplane Board

Installing a RAID Controller Card

Your system supports the following drives:

l Up to two externally accessible 5.25-inch drives (typically optical and tape backup drives). An optical drive is standard in the first external drive bay, and a tape backup device can be installed in the second external drive bay.

l An externally accessible 3.5-inch diskette drive.

l Up to four 1-inch SATA or SCSI hard drives. Four hard drive configurations are available:

Cabled SATA drives. See "Cabled SATA and SCSI Hard Drives."

Cabled SCSI drives (requires optional SCSI controller card). See "Cabled SATA and SCSI Hard Drives."

Front-access (non-hot-plug) SCSI drives (requires optional SCSI backplane and optional SCSI controller card). See "Front-Access SCSI Hard Drives (Non-Hot-Plug)" and "Installing the Optional SCSI Backplane Board."

Hot-plug SCSI drives (requires optional SCSI backplane and optional SCSI RAID controller). See "Hot-Plug SCSI Hard Drives," "Installing a RAID Controller Card," and "Installing the Optional SCSI Backplane Board."-+

Connecting Drives

Interface Cables

Most interface connectors are keyed for correct insertion. Keying ensures that the pin-1 wire in the cable connects to pin 1 in the connectors on both ends. When you disconnect an interface cable, take care to grasp the cable connector, rather than the cable itself, to avoid stress on the cable.

Drive Cable Configurations

Your system can accommodate many different drive configurations, each with specific cable requirements. Table 7-1 shows the cable requirements for common drive configurations.

Table 7-1. Drive Cable Configuration

DC Power Cables

Each drive must connect to a DC power cable from the system power supply. These power cables are used for the 3.5-inch diskette drive, 5.25-inch devices, and hard drives.

NOTE: Installing SATA and SCSI hard drives in the same system is not supported.

Drives

Required Cable

Cable Connections

IDE optical drives, and IDE and SCSI tape drives (See Figure 7-4.)

40-pin IDE 2-drop cable or SCSI 1- drop cable (terminated)

IDE drive and primary IDE connector on system board or the SCSI tape device and the SCSI controller card

Up to four cabled SATA hard drives (See Figure 7-7.) 7-pin SATA hard-drive cable (one cable per drive)

SATA hard drives and SATA port connectors on the system board, or on a RAID controller card.

Up to four cabled (non-hot-plug) SCSI hard-drives (See Figure 7-9.)

94-cm (37-inch) SCSI 4-drop cable (terminated)

SCSI hard drives and SCSI RAID controller or SCSI controller card

Up to four front-access or hot-plug SCSI hard drives connected to the SCSI backplane (See Figure 7-12.)

38-cm (15-inch) 68-pin SCSI 1-drop cable (unterminated)

SCSI backplane and the SCSI controller card

NOTICE: To avoid electrical damage to internal system components, install a cover connector on any unused connectors on hard-drive power cables.

Front-Panel Drive Inserts

To help keep dust and dirt out of the system, a plastic insert in the bezel covers each empty external drive bay. Additionally, each empty external drive bay is covered by a metal insert in the chassis to maintain Federal Communications Commission (FCC) certification of the system.

Before you install a 5.25-inch drive in an empty external drive bay, you must first remove both front-panel drive inserts. If you remove a 5.25-inch drive permanently, you must install both inserts.

Removing the Front-Panel Drive Inserts

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

3. Remove the bezel drive insert (see Figure 7-1):

a. From inside the bezel, press the center of the insert outward with your thumbs to loosen the tabs on the sides of the insert.

b. Pull the insert out of the bezel.

4. Remove the chassis drive insert (see Figure 7-1):

a. Press both sides of the insert to loosen the tabs on the insert.

b. Pull the insert out of the chassis.

Figure 7-1. Removing the Front-Panel Drive Inserts

Installing the Front-Panel Drive Inserts

1. Install the chassis drive insert by sliding the insert into the chassis until tabs on the side of the insert snap into place. See Figure 7-1.

2. Install the bezel drive insert by sliding the insert into the bezel until the tabs on the side of the insert snap into place. See Figure 7-1.

3. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

CAUTION: See your System Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

NOTICE: You must install both inserts in an empty 5.25-inch drive bay to maintain Federal Communications Commission (FCC) certification of the system. The inserts also help keep dust and dirt out of the system.

4. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Diskette Drive

Removing a Diskette Drive

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

3. Lay the system on its right side.

4. Remove the cover. See "Removing the Cover" in "Troubleshooting Your System."

5. Disconnect the power cable and the interface cable from the diskette drive. See Figure 7-2.

6. Remove the two screws that secure the diskette drive in the externally accessible drive bay. See Figure 7-2.

7. Slide the diskette drive forward out of the drive bay.

Installing a Diskette Drive

1. Unpack the drive and prepare the drive for installation.

For instructions, see the documentation that accompanied the drive.

2. Slide the diskette drive into the externally accessible drive bay.

3. Install the two screws that secure the diskette drive in the drive bay. See Figure 7-2.

4. Connect the power cable and the interface cable to the diskette drive. See Figure 7-2.

5. Install the cover. See "Replacing the Cover" in "Troubleshooting Your System."

6. Stand the system upright.

7. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."

8. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

Figure 7-2. Removing or Installing a Diskette Drive

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

5.25-Inch Drives

An optical drive is standard in the first external drive bay. An additional IDE or SCSI tape backup device can be installed in the second external drive bay. These drives connect either to the system board or to an optional controller card.

Installing a 5.25-Inch Drive

1. Unpack the drive (and controller card, if applicable), and prepare the drive for installation.

For instructions, see the documentation that accompanied the drive.

2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

3. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

4. Lay the system on its right side.

5. Remove the cover. See "Removing the Cover" in "Troubleshooting Your System."

6. Remove the cooling shroud. See "Removing the Cooling Shroud" in "Installing System Components."

7. Remove the front-panel inserts for the empty external drive bay. See "Removing the Front- Panel Drive Inserts."

8. Slide the drive into the external drive bay.

9. Install the screws that secure the drive in the drive bay. See Figure 7-3.

Figure 7-3. Installing or Removing a 5.25-Inch Drive

NOTE: Installing an additional optical drive in the second external drive bay is not supported.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

NOTE: If you are installing a SCSI tape drive, you must install an Ultra 3 SCSI controller card. The optional SCSI RAID controller card does not support a SCSI tape drive.

10. If a controller card was supplied with the drive, install the controller card in expansion slot 3, 4, or 5. See "Installing an Expansion Card" in "Installing

System Components."

11. Connect a power cable to the drive. See Figure 7-3.

12. Connect the interface cable to the drive and to the appropriate connector on the system board or controller card (if applicable).

If you are installing an IDE device (such as an optical drive), connect the interface cable to the IDE device and the IDE connector on the system board. See Figure 7-4.

If you are installing a SCSI device in the second drive bay (such as a tape backup device), connect the interface cable to the device and to channel A on the SCSI controller card. See Figure 7-4.

See Figure A-3 to locate the system board connectors.

Figure 7-4. Connecting a Tape Drive to a SCSI Controller Card

13. Ensure that all cables are firmly connected and arranged so that they will not catch on the computer cover or block airflow inside the system.

14. Install the cooling shroud. See "Installing the Cooling Shroud" in "Installing System Components."

15. Install the cover. See "Replacing the Cover" in "Troubleshooting Your System."

16. Stand the system upright.

NOTE: See the documentation that is included with the controller card for more information.

NOTE: A SCSI device attached to a SCSI controller card and an IDE device attached to the system board can be installed together as shown in Figure 7-4.

17. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."

18. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

19. Test the drive.

If you installed an IDE device, run the IDE devices tests in the system diagnostics to determine whether the device operates properly. See "Running the System Diagnostics."

If you installed a SCSI device, run the SCSI controllers test in the system diagnostics. See "Running the System Diagnostics."

If you installed a tape drive, see the tape drive software documentation to perform a backup and verification test.

Hard Drives

Your system can contain up to four 1-inch SATA or SCSI hard drives in a optional removable hard-drive bay (see Figure 7-5). These drives connect either to the system board or to an optional controller card.

General Installation Guidelines

Use the following guidelines when installing hard drives:

l You should only use drives that have been tested and approved by the system manufacturer.

l Do not install a mixture of SATA and SCSI hard drives. All hard drives must either be SCSI drives or SATA drives.

l You may need to use different programs than those provided with the operating system to partition and format a hard drive. See the hard drive's documentation for information on setting up the drive.

l When you format a high-capacity hard drive, allow enough time for the formatting to be completed. Long format times for these drives are normal. For example, a large drive can take over an hour to format.

l Do not turn off or reboot your system while the drive is being formatted. Doing so can cause a drive failure.

Configuring the Boot Drive

The drive or device from which the system boots is determined by the boot order specified in the System Setup program (see "Using the System Setup Program" in your User's Guide). To boot the system from a hard drive or drive array, the drive(s) must be connected to the appropriate controller:

l To boot from a single SATA hard drive, the master drive (drive 0) must be connected to the SATA_0 connector on the system board. To identify system board connectors, see Figure A-3.

l To boot from a single SCSI hard drive, the drive must be connected to a SCSI controller card. See the documentation that accompanied the controller card.

Cabled SATA and SCSI Hard Drives

Removing a Cabled Hard Drive

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

3. Lay the system on its right side.

4. Remove the cover. See "Removing the Cover" in "Troubleshooting Your System."

5. Remove the cooling shroud. See "Removing the Cooling Shroud" in "Installing System Components."

6. Disconnect the interface and power cables to the hard drives in the drive bay.

NOTE: The hard-drive activity indicator operates only when SATA hard drives are connected directly to the SATA port connectors on the system board. The indicator does not operate with SCSI drives or SATA drives that are attached to a RAID controller card. To identify the indicator, see Figure 2-1.

CAUTION: See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

7. Remove the hard-drive bay. See Figure 7-5 and Figure 7-6.

a. Loosen the four screws that secure the drive bay to the system.

b. Slide the hard-drive bay out of the system.

8. Remove the drive from the drive bay. See Figure 7-5 and Figure 7-6.

a. Remove the screws that secure the drive in the hard-drive bay.

b. Slide the drive out of the drive bay.

Figure 7-5. Installing or Removing a SATA Hard Drive

Figure 7-6. Installing or Removing a Cabled SCSI Hard Drive

Installing a Cabled Hard Drive

1. Unpack the drive (and controller card, if applicable), and prepare the drive for installation.

For instructions, see the documentation that accompanied the drive.

2. Install the hard drive in the hard-drive bay:

a. Slide the drive into the drive bay with the back of the drive toward the back of the drive bay.

b. Install the screws that secure the drive in the drive bay.

3. Install the hard-drive bay (see Figure 7-5 and Figure 7-6):

a. Slide the drive bay into the system until the drive bay contacts the system.

b. Install the four screws that secure the drive bay in the system.

4. Connect a power cable to each hard drive. See Figure 7-5 and Figure 7-6.

5. Connect the hard-drive interface cables to each hard drive.

If you are installing a SATA hard drive, connect the SATA interface cable to the hard drives and to the SATA ports on the system board (see Figure 7-7) or SATA RAID controller board (when available) (see Figure 7-8).

If you are installing a cabled SCSI drive, connect the SCSI interface cable to the hard drives and to the SCSI controller card. See Figure 7-9.

Figure 7-7. Connecting SATA Hard Drives to the Integrated Drive Controller

Figure 7-8. Connecting SATA Drives to a SATA RAID Controller Card

NOTICE: To prevent damage to internal system components, ensure that a connector cap is installed on each available power connector that is not connected to a hard drive.

Figure 7-9. Cabling Four SCSI Hard Drives to the SCSI Controller Card

6. Ensure that all cables are firmly connected and arranged so that they will not catch on the computer cover or block airflow inside the system.

7. Install the cooling shroud. See "Installing the Cooling Shroud" in "Installing System Components."

8. Install the cover. See "Replacing the Cover" in "Troubleshooting Your System."

9. Stand the system upright.

10. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."

11. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

12. Partition and logically format the hard drive. See the operating system documentation for more information.

13. Install any required device drivers.

14. Run the hard drive tests in the system diagnostics to determine whether the drive operates properly. See "Running the System Diagnostics."

If the drive is connected to a SATA RAID controller card, see the RAID controller card documentation for information on testing the controller.

If the drive is connected to a SCSI controller card, run the SCSI controller tests and the hard-drive tests in the system diagnostics. See "Running the System Diagnostics."

If the hard drive fails the hard-drive tests or does not operate properly, see "Getting Help."

Front-Access SCSI Hard Drives (Non-Hot-Plug)

The drive bays in a system with an optional SCSI backplane board and optional non-RAID SCSI controller card provide space for up to four front-access SCSI hard drives. The hard drives plug into the SCSI backplane board, which is connected to the controller card (see Figure 7-10.) For instructions on installing the optional SCSI backplane board, see "Installing the Optional SCSI Backplane Board."

Figure 7-10. SCSI Hard Drives Connected to a SCSI Controller Card

Removing a Front-Access SCSI Hard Drive (Non-Hot-Plug)

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

3. Open the hard-drive carrier handle to release the drive. See Figure 7-11.

4. Slide the hard drive out until it is free of the drive bay.

Figure 7-11. Removing or Installing a SCSI Hard-Drive Carrier

Installing a Front-Access SCSI Hard Drive (Non-Hot-Plug)

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

3. Open the hard-drive carrier handle. See Figure 7-11.

4. Insert the hard-drive carrier into the drive bay. See Figure 7-11.

5. Close the hard-drive carrier handle to lock it in place.

NOTICE: To prevent data loss, you must shut down the system before removing a SCSI drive carrier, unless a SCSI RAID controller is connected to the SCSI backplane. See "Hot-Plug SCSI Hard Drives" for information on hot-plug drive requirements and operation.

NOTICE: Do not insert a hard-drive carrier and attempt to lock its handle next to a partially installed carrier. Doing so can damage the partially installed carrier's shield spring and make it unusable. Ensure that the adjacent drive carrier is fully installed.

6. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."

7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

8. Install any required SCSI device drivers.

9. Run the SCSI controllers tests and the hard-drive tests in the system diagnostics. See "Running the System Diagnostics."

If the hard drive fails the hard-drive tests or does not operate properly, see "Getting Help."

Hot-Plug SCSI Hard Drives

Systems with an optional SCSI backplane board and an optional SCSI RAID controller card support up to four hot-plug hard drives. The hard drives plug into the SCSI backplane board, which is connected to channel A on the optional SCSI RAID controller card (see Figure 7-12). For instructions on installing the optional SCSI backplane board, see "Installing the Optional SCSI Backplane Board."

Figure 7-12. Hot-Plug SCSI Hard Drives Connected to a SCSI RAID Controller Card

Removing a Hot-Plug SCSI Hard Drive

1. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

2. Take the hard drive offline and wait until the hard-drive indicator codes on the drive carrier signal that the drive can be removed safely. See Table 2-3 for a list of hard-drive indicator codes.

If the drive has been online, the drive status indicator will blink green 2 times per second as the drive is powered down. When all indicators are off, the drive is ready for removal.

See your operating system documentation for more information on taking the hard drive offline.

3. Open the hard-drive carrier handle to release the drive. See Figure 7-11.

4. Slide the hard drive out until it is free of the drive bay.

Installing a Hot-Plug SCSI Hard Drive

1. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

2. Open the hard-drive carrier handle. See Figure 7-11.

NOTICE: Not all operating systems support hot-plug drive installation. See the operating system documentation to confirm that the operating system supports this feature.

NOTICE: Do not insert a hard-drive carrier and attempt to lock its handle next to a partially installed carrier. Doing so can damage the partially installed carrier's shield spring and make it unusable. Ensure that the adjacent drive carrier is fully installed.

3. Insert the hard-drive carrier into the drive bay. See Figure 7-11.

4. Close the hard-drive carrier handle to lock it in place.

5. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."

6. Install any required SCSI device drivers.

7. Run the SCSI controllers tests and the hard-drive tests in the system diagnostics. See "Running the System Diagnostics."

If the hard drive fails the hard-drive tests or does not operate properly, see "Getting Help."

Installing the Optional SCSI Backplane Board

The optional SCSI backplane board supports front-access SCSI drives (if an optional SCSI controller card is installed in the system) or hot-plug SCSI drives (if an optional RAID controller card is installed in the system). A new drive cage is supplied with the SCSI backplane.

1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2. Remove the bezel. See "Removing the Bezel" in "Troubleshooting Your System."

3. Lay the system on its right side.

4. Remove the cover. See "Removing the Cover" in "Troubleshooting Your System."

5. Remove the cooling shroud. See "Removing the Cooling Shroud" in "Installing System Components."

6. Disconnect the SATA or SCSI interface cables from the hard drives.

7. Disconnect the wiring harness from power cable connector P3.

8. Remove the hard-drive bay from the system. See Figure 7-6.

a. Loosen the four screws that secure the drive bay to the system.

Retain the screws to use when installing the new drive cage.

b. Slide the hard-drive bay out of the system.

9. Slide the new drive cage into the system and secure it with the four Phillips screws you removed in step 8.

10. Install the SCSI backplane:

a. Lower the backplane into the system and align the backplane with the retention hooks on the drive cage, then fit the backplane over the retention hooks.

b. Slide the backplane board toward the front fan about 12 mm (0.5 inch).

c. Secure the backplane with the thumbscrew. See Figure 7-13.

Figure 7-13. Installing the SCSI Backplane Board

CAUTION: See the Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

11. Connect the power cable connector P3 to the power connector on the SCSI backplane. See Figure 7-13.

12. Connect the baseboard management controller (BMC) inter-IC (I2C) cable to the SCSI backplane. See Figure 7-13.

13. Connect the other end of the BMC I2C cable to connector BP_I2C on the system board. See Figure A-3.

14. Install the SCSI controller card.

See "Installing an Expansion Card" in "Installing System Components" for instructions about installing the card.

15. Connect the SCSI data cable to the SCSI controller card, and to the SCSI interface connector on the backplane. See Figure 7-12 and Figure 7-13.

16. Install the cover. See "Replacing the Cover" in "Troubleshooting Your System."

17. Stand the system upright.

18. Install the SCSI drives into the hard-drive bay.

See Figure 7-11.

19. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."

20. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

21. Install any required SCSI device drivers.

22. Run the SCSI controllers tests and the hard-drive tests in the system diagnostics. See "Running the System Diagnostics."

Installing a RAID Controller Card

See "Installing an Expansion Card" in "Installing System Components" for instructions about installing the card.

Back to Contents Page

Back to Contents Page

Getting Help Dell PowerEdge 800 Systems Installation and Troubleshooting Guide

Technical Assistance

Dell Enterprise Training and Certification

Problems With Your Order

Product Information

Returning Items for Warranty Repair or Credit

Before You Call

Contacting Dell

Technical Assistance

If you need assistance with a technical problem, perform the following steps:

1. Complete the procedures in "Troubleshooting Your System."

2. Run the system diagnostics and record any information provided.

3. Make a copy of the Diagnostics Checklist, and fill it out.

4. Use Dell's extensive suite of online services available at Dell Support at support.dell.com for help with installation and troubleshooting procedures.

For more information, see "Online Services."

5. If the preceding steps have not resolved the problem, call Dell for technical assistance.

NOTE: Call technical support from a phone near or at the system so that technical support can assist you with any necessary procedures.

NOTE: Dell's Express Service Code system may not be available in all countries.

When prompted by Dell's automated telephone system, enter your Express Service Code to route the call directly to the proper support personnel. If you do not have an Express Service Code, open the Dell Accessories folder, double-click the Express Service Code icon, and follow the directions.

For instructions on using the technical support service, see "Technical Support Service" and "Before You Call."

NOTE: Some of the following services are not always available in all locations outside the continental U.S. Call your local Dell representative for information on availability.

Online Services

You can access Dell Support at support.dell.com. Select your region on the WELCOME TO DELL SUPPORT page, and fill in the requested details to access help tools and information.

You can contact Dell electronically using the following addresses:

l World Wide Web

www.dell.com/

www.dell.com/ap/ (Asian/Pacific countries only)

www.dell.com/jp (Japan only)

www.euro.dell.com (Europe only)

www.dell.com/la (Latin American countries)

www.dell.ca (Canada only)

l Anonymous file transfer protocol (FTP)

ftp.dell.com/

Log in as user:anonymous, and use your e-mail address as your password.

l Electronic Support Service

support@us.dell.com

apsupport@dell.com (Asian/Pacific countries only)

support.jp.dell.com (Japan only)

support.euro.dell.com (Europe only)

l Electronic Quote Service

sales@dell.com

apmarketing@dell.com (Asian/Pacific countries only)

sales_canada@dell.com (Canada only)

l Electronic Information Service

info@dell.com

AutoTech Service

Dell's automated technical support serviceAutoTechprovides recorded answers to the questions most frequently asked by Dell customers about their portable and desktop computer systems.

When you call AutoTech, use your touch-tone telephone to select the subjects that correspond to your questions.

The AutoTech service is available 24 hours a day, 7 days a week. You can also access this service through the technical support service. See the contact information for your region.

Automated Order-Status Service

To check on the status of any Dell products that you have ordered, you can go to support.dell.com, or you can call the automated order-status service. A recording prompts you for the information needed to locate and report on your order. See the contact information for your region.

Technical Support Service

Dell's technical support service is available 24 hours a day, 7 days a week, to answer your questions about Dell hardware. Our technical support staff use computer-based diagnostics to provide fast, accurate answers.

To contact Dell's technical support service, see "Before You Call" and then see the contact information for your region.

Dell Enterprise Training and Certification

Dell Enterprise Training and Certification is available; see www.dell.com/training for more information. This service may not be offered in all locations.

Problems With Your Order

If you have a problem with your order, such as missing parts, wrong parts, or incorrect billing, contact Dell for customer assistance. Have your invoice or packing slip available when you call. See the contact information for your region.

Product Information

If you need information about additional products available from Dell, or if you would like to place an order, visit the Dell website at www.dell.com. For the telephone number to call to speak to a sales specialist, see the contact information for your region.

Returning Items for Warranty Repair or Credit

Prepare all items being returned, whether for repair or credit, as follows:

1. Call Dell to obtain a Return Material Authorization Number, and write it clearly and prominently on the outside of the box.

For the telephone number to call, see the contact information for your region.

2. Include a copy of the invoice and a letter describing the reason for the return.

3. Include a copy of any diagnostic information (including the Diagnostics Checklist) indicating the tests you have run and any error messages reported by

the system diagnostics.

4. Include any accessories that belong with the item(s) being returned (such as power cables, media such as CDs and diskettes, and guides) if the return is for credit.

5. Pack the equipment to be returned in the original (or equivalent) packing materials.

You are responsible for paying shipping expenses. You are also responsible for insuring any product returned, and you assume the risk of loss during shipment to Dell. Collect-on-delivery (C.O.D.) packages are not accepted.

Returns that are missing any of the preceding requirements will be refused at our receiving dock and returned to you.

Before You Call

NOTE: Have your Express Service Code ready when you call. The code helps Dell's automated-support telephone system direct your call more efficiently.

Remember to fill out the Diagnostics Checklist. If possible, turn on your system before you call Dell for technical assistance and call from a telephone at or near the computer. You may be asked to type some commands at the keyboard, relay detailed information during operations, or try other troubleshooting steps possible only at the computer system itself. Ensure that the system documentation is available.

Contacting Dell

To contact Dell electronically, you can access the following websites:

l www.dell.com

l support.dell.com (technical support)

l premiersupport.dell.com (technical support for educational, government, healthcare, and medium/large business customers, including Premier, Platinum, and Gold customers)

For specific web addresses for your country, find the appropriate country section in the table below.

When you need to contact Dell, use the electronic addresses, telephone numbers, and codes provided in the following table. If you need assistance in determining which codes to use, contact a local or an international operator.

CAUTION: Before servicing any components inside your computer, see your Product Information Guide for important safety information.

Diagnostics Checklist

Name:

Date:

Address:

Phone number:

Service Tag (bar code on the back of the computer):

Express Service Code:

Return Material Authorization Number (if provided by Dell support technician):

Operating system and version:

Peripherals:

Expansion cards:

Are you connected to a network? Yes No

Network, version, and network card:

Programs and versions:

See your operating system documentation to determine the contents of the system's start-up files. If possible, print each file. Otherwise, record the contents of each file before calling Dell.

Error message, beep code, or diagnostic code:

Description of problem and troubleshooting procedures you performed:

NOTE: Toll-free numbers are for use within the country for which they are listed.

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and

Country (City) International Access Code Country Code City Code

Toll-Free Numbers

Anguilla General Support toll-free: 800-335-0031

Antigua and Barbuda General Support 1-800-805-5924

Argentina (Buenos Aires)

International Access Code: 00

Country Code: 54

City Code: 11

Website: www.dell.com.ar

E-mail: us_latin_services@dell.com

E-mail for desktop and portable computers: la-techsupport@dell.com

E-mail for servers and EMC: la_enterprise@dell.com

Customer Care toll-free: 0-800-444-0730

Tech Support toll-free: 0-800-444-0733

Tech Support Services toll-free: 0-800-444-0724

Sales 0-810-444-3355

Aruba General Support toll-free: 800-1578

Australia (Sydney)

International Access Code: 0011

Country Code: 61

City Code: 2

E-mail (Australia): au_tech_support@dell.com

E-mail (New Zealand): nz_tech_support@dell.com

Home and Small Business 1-300-655-533

Government and Business toll-free: 1-800-633-559

Preferred Accounts Division (PAD) toll-free: 1-800-060-889

Customer Care toll-free: 1-800-819-339

Technical Support (portables and desktops) toll-free: 1-300-655-533

Technical Support (servers and workstations) toll-free: 1-800-733-314

Corporate Sales toll-free: 1-800-808-385

Transaction Sales toll-free: 1-800-808-312

Fax toll-free: 1-800-818-341

Austria (Vienna)

International Access Code: 900

Country Code: 43

City Code: 1

Website: support.euro.dell.com

E-mail: tech_support_central_europe@dell.com

Home/Small Business Sales 0820 240 530 00

Home/Small Business Fax 0820 240 530 49

Home/Small Business Customer Care 0820 240 530 14

Preferred Accounts/Corporate Customer Care 0820 240 530 16

Home/Small Business Technical Support 0820 240 530 14

Preferred Accounts/Corporate Technical Support 0660 8779

Switchboard 0820 240 530 00

Bahamas General Support toll-free: 1-866-278-6818

Barbados General Support 1-800-534-3066

Belgium (Brussels)

International Access Code: 00

Country Code: 32

City Code: 2

Website: support.euro.dell.com

E-mail for French Speaking Customers: support.euro.dell.com/be/fr/emaildell/

Technical Support 02 481 92 88

Technical Support Fax 02 481 92 95

Customer Care 02 713 15 .65

Corporate Sales 02 481 91 00

Fax 02 481 92 99

Switchboard 02 481 91 00

Bermuda General Support 1-800-342-0671

Bolivia General Support toll-free: 800-10-0238

Brazil

International Access Code: 00

Country Code: 55

City Code: 51

Website: www.dell.com/br

Customer Support, Technical Support 0800 90 3355

Technical Support Fax 51 481 5470

Customer Care Fax 51 481 5480

Sales 0800 90 3390

British Virgin Islands General Support toll-free: 1-866-278-6820

Brunei

Country Code: 673

Customer Technical Support (Penang, Malaysia) 604 633 4966

Customer Service (Penang, Malaysia) 604 633 4949

Transaction Sales (Penang, Malaysia) 604 633 4955

Canada (North York, Ontario)

International Access Code:

Online Order Status: www.dell.ca/ostatus

AutoTech (automated technical support) toll-free: 1-800-247-9362

011 Customer Care (Home Sales/Small Business) toll-free: 1-800-847-4096

Customer Care (med./large business, government) toll-free: 1-800-326-9463

Technical Support (Home Sales/Small Business) toll-free: 1-800-847-4096

Technical Support (med./large bus., government) toll-free: 1-800-387-5757

Sales (Home Sales/Small Business) toll-free: 1-800-387-5752

Sales (med./large bus., government) toll-free: 1-800-387-5755

Spare Parts Sales & Extended Service Sales 1 866 440 3355

Cayman Islands General Support 1-800-805-7541

Chile (Santiago)

Country Code: 56

City Code: 2

Sales, Customer Support, and Technical Support toll-free: 1230-020-4823

China (Xiamen)

Country Code: 86

City Code: 592

Technical Support website: support.dell.com.cn

Technical Support E-mail: cn_support@dell.com

Customer Care E-mail: customer_cn@dell.com

Technical Support Fax 818 1350

Technical Support (Dimension and Inspiron) toll-free: 800 858 2969

Technical Support (OptiPlex, Latitude, and Dell Precision) toll-free: 800 858 0950

Technical Support (servers and storage) toll-free: 800 858 0960

Technical Support (projectors, PDAs, printers, switches, routers, and so on) toll-free: 800 858 2920

Customer Care toll-free: 800 858 2060

Customer Care Fax 592 818 1308

Home and Small Business toll-free: 800 858 2222

Preferred Accounts Division toll-free: 800 858 2557

Large Corporate Accounts GCP toll-free: 800 858 2055

Large Corporate Accounts Key Accounts toll-free: 800 858 2628

Large Corporate Accounts North toll-free: 800 858 2999

Large Corporate Accounts North Government and Education toll-free: 800 858 2955

Large Corporate Accounts East toll-free: 800 858 2020

Large Corporate Accounts East Government and Education toll-free: 800 858 2669

Large Corporate Accounts Queue Team toll-free: 800 858 2572

Large Corporate Accounts South toll-free: 800 858 2355

Large Corporate Accounts West toll-free: 800 858 2811

Large Corporate Accounts Spare Parts toll-free: 800 858 2621

Colombia General Support 980-9-15-3978

Costa Rica General Support 0800-012-0435

Czech Republic (Prague)

International Access Code: 00

Country Code: 420

Website: support.euro.dell.com

E-mail: czech_dell@dell.com

Technical Support 22537 2727

Customer Care 22537 2707

Fax 22537 2714

Tech Fax 22537 2728

Switchboard 22537 2711

Denmark (Copenhagen)

International Access Code: 00

Country Code: 45

Website: support.euro.dell.com

E-mail: http://support.euro.dell.com/dk/da/emaildell/

Technical Support 7023 0182

Customer Care (Relational) 7023 0184

Home/Small Business Customer Care 3287 5505

Switchboard (Relational) 3287 1200

Switchboard Fax (Relational) 3287 1201

Switchboard (Home/Small Business) 3287 5000

Switchboard Fax (Home/Small Business) 3287 5001

Dominica General Support toll-free: 1-866-278-6821

Dominican Republic General Support 1-800-148-0530

Ecuador General Support toll-free: 999-119

El Salvador General Support 01-899-753-0777

Finland (Helsinki) Website: support.euro.dell.com

International Access Code: 990

Country Code: 358

City Code: 9

E-mail: http://support.euro.dell.com/fi/fi/emaildell/

Technical Support 09 253 313 60

Customer Care 09 253 313 38

Fax 09 253 313 99

Switchboard 09 253 313 00

France (Paris) (Montpellier)

International Access Code: 00

Country Code: 33

City Codes: (1) (4)

Website: support.euro.dell.com

E-mail: support.euro.dell.com/fr/fr/emaildell/

Home and Small Business

Technical Support 0825 387 270

Customer Care 0825 823 833

Switchboard 0825 004 700

Switchboard (calls from outside of France) 04 99 75 40 00

Sales 0825 004 700

Fax 0825 004 701

Fax (calls from outside of France) 04 99 75 40 01

Corporate

Technical Support 0825 004 719

Customer Care 0825 338 339

Switchboard 01 55 94 71 00

Sales 01 55 94 71 00

Fax 01 55 94 71 01

Germany (Langen)

International Access Code: 00

Country Code: 49

City Code: 6103

Website: support.euro.dell.com

E-mail: tech_support_central_europe@dell.com

Technical Support 06103 766-7200

Home/Small Business Customer Care 0180-5-224400

Global Segment Customer Care 06103 766-9570

Preferred Accounts Customer Care 06103 766-9420

Large Accounts Customer Care 06103 766-9560

Public Accounts Customer Care 06103 766-9555

Switchboard 06103 766-7000

Greece

International Access Code: 00

Country Code: 30

Website: support.euro.dell.com

E-mail: support.euro.dell.com/gr/en/emaildell/

Technical Support 00800-44 14 95 18

Gold Service Technical Support 00800-44 14 00 83

Switchboard 2108129810

Gold Service Switchboard 2108129811

Sales 2108129800

Fax 2108129812

Grenada General Support toll-free: 1-866-540-3355

Guatemala General Support 1-800-999-0136

Guyana General Support toll-free: 1-877-270-4609

Hong Kong

International Access Code: 001

Country Code: 852

Website: support.ap.dell.com

Technical Support E-mail: apsupport@dell.com

Technical Support (Dimension and Inspiron) 2969 3188

Technical Support (OptiPlex, Latitude, and Dell Precision) 2969 3191

Technical Support (PowerApp, PowerEdge, PowerConnect, and PowerVault)

2969 3196

Customer Care 3416 0910

Large Corporate Accounts 3416 0907

Global Customer Programs 3416 0908

Medium Business Division 3416 0912

Home and Small Business Division 2969 3105

India Technical Support 1600 33 8045

Sales (Large Corporate Accounts) 1600 33 8044

Sales (Home and Small Business) 1600 33 8046

Ireland (Cherrywood)

International Access Code: 16

Country Code: 353

Website: support.euro.dell.com

E-mail: dell_direct_support@dell.com

Technical Support 1850 543 543

U.K. Technical Support (dial within U.K. only) 0870 908 0800

City Code: 1 Home User Customer Care 01 204 4014

Small Business Customer Care 01 204 4014

U.K. Customer Care (dial within U.K. only) 0870 906 0010

Corporate Customer Care 1850 200 982

Corporate Customer Care (dial within U.K. only) 0870 907 4499

Ireland Sales 01 204 4444

U.K. Sales (dial within U.K. only) 0870 907 4000

Fax/Sales Fax 01 204 0103

Switchboard 01 204 4444

Italy (Milan)

International Access Code: 00

Country Code: 39

City Code: 02

Website: support.euro.dell.com

E-mail: support.euro.dell.com/it/it/emaildell/

Home and Small Business

Technical Support 02 577 826 90

Customer Care 02 696 821 14

Fax 02 696 821 13

Switchboard 02 696 821 12

Corporate

Technical Support 02 577 826 90

Customer Care 02 577 825 55

Fax 02 575 035 30

Switchboard 02 577 821

Jamaica General Support (dial from within Jamaica only) 1-800-682-3639

Japan (Kawasaki)

International Access Code: 001

Country Code: 81

City Code: 44

Website: support.jp.dell.com

Technical Support (servers) toll-free: 0120-198-498

Technical Support outside of Japan (servers) 81-44-556-4162

Technical Support (Dimension and Inspiron) toll-free: 0120-198-226

Technical Support outside of Japan (Dimension and Inspiron) 81-44-520-1435

Technical Support (Dell Precision, OptiPlex, and Latitude) toll-free:0120-198-433

Technical Support outside of Japan (Dell Precision, OptiPlex, and Latitude) 81-44-556-3894

Technical Support (PDAs, projectors, printers, routers) toll-free: 0120-981-690

Technical Support outside of Japan (PDAs, projectors, printers, routers) 81-44-556-3468

Faxbox Service 044-556-3490

24-Hour Automated Order Service 044-556-3801

Customer Care 044-556-4240

Business Sales Division (up to 400 employees) 044-556-1465

Preferred Accounts Division Sales (over 400 employees) 044-556-3433

Large Corporate Accounts Sales (over 3500 employees) 044-556-3430

Public Sales (government agencies, educational institutions, and medical institutions)

044-556-1469

Global Segment Japan 044-556-3469

Individual User 044-556-1760

Switchboard 044-556-4300

Korea (Seoul)

International Access Code: 001

Country Code: 82

City Code: 2

Technical Support toll-free: 080-200-3800

Sales toll-free: 080-200-3600

Customer Service (Penang, Malaysia) 604 633 4949

Fax 2194-6202

Switchboard 2194-6000

Technical Support (Electronics and Accessories) toll-free: 080-200-3801

Latin America Customer Technical Support (Austin, Texas, U.S.A.) 512 728-4093

Customer Service (Austin, Texas, U.S.A.) 512 728-3619

Fax (Technical Support and Customer Service) (Austin, Texas, U.S.A.) 512 728-3883

Sales (Austin, Texas, U.S.A.) 512 728-4397

SalesFax (Austin, Texas, U.S.A.) 512 728-4600

or 512 728-3772

Luxembourg

International Access Code: 00

Country Code: 352

Website: support.euro.dell.com

E-mail: tech_be@dell.com

Technical Support (Brussels, Belgium) 3420808075

Home/Small Business Sales (Brussels, Belgium) toll-free: 080016884

Corporate Sales (Brussels, Belgium) 02 481 91 00

Customer Care (Brussels, Belgium) 02 481 91 19

Fax (Brussels, Belgium) 02 481 92 99

Switchboard (Brussels, Belgium) 02 481 91 00

Macao

Country Code: 853

Technical Support toll-free: 0800 105

Customer Service (Xiamen, China) 34 160 910

Transaction Sales (Xiamen, China) 29 693 115

Malaysia (Penang)

International Access Code: 00

Country Code: 60

City Code: 4

Website: support.ap.dell.com toll-free: 1 800 88 0193

Technical Support (Dell Precision, OptiPlex, and Latitude) toll-free: 1 800 88 1306

Technical Support (Dimension, Inspiron, and Electronics and Accessories)

Technical Support (PowerApp, PowerEdge, PowerConnect, and PowerVault) toll-free: 1800 88 1386

Customer Service (Penang, Malaysia) 04 633 4949

Transaction Sales toll-free: 1 800 888 202

Corporate Sales toll-free: 1 800 888 213

Mexico

International Access Code: 00

Country Code: 52

Customer Technical Support 001-877-384-8979

or 001-877-269-3383

Sales 50-81-8800

or 01-800-888-3355

Customer Service 001-877-384-8979

or 001-877-269-3383

Main 50-81-8800

or 01-800-888-3355

Montserrat General Support toll-free: 1-866-278-6822

Netherlands Antilles General Support 001-800-882-1519

Netherlands (Amsterdam)

International Access Code: 00

Country Code: 31

City Code: 20

Website: support.euro.dell.com

Technical Support 020 674 45 00

Technical Support Fax 020 674 47 66

Home/Small Business Customer Care 020 674 42 00

Relational Customer Care 020 674 4325

Home/Small Business Sales 020 674 55 00

Relational Sales 020 674 50 00

Home/Small Business Sales Fax 020 674 47 75

Relational Sales Fax 020 674 47 50

Switchboard 020 674 50 00

Switchboard Fax 020 674 47 50

New Zealand

International Access Code: 00

Country Code: 64

E-mail (New Zealand): nz_tech_support@dell.com

E-mail (Australia): au_tech_support@dell.com

Technical Support (for desktop and portable computers) toll-free: 0800 446 255

Technical Support (for servers and workstations) toll-free: 0800 443 563

Home and Small Business 0800 446 255

Government and Business 0800 444 617

Sales 0800 441 567

Fax 0800 441 566

Nicaragua General Support 001-800-220-1006

Norway (Lysaker)

International Access Code: 00

Country Code: 47

Website: support.euro.dell.com

E-mail: http://support.euro.dell.com/no/no/emaildell/

Technical Support 671 16882

Relational Customer Care 671 17575

Home/Small Business Customer Care 23162298

Switchboard 671 16800

Fax Switchboard 671 16865

Panama General Support 001-800-507-0962

Peru General Support 0800-50-669

Poland (Warsaw)

International Access Code: 011

Country Code: 48

City Code: 22

Website: support.euro.dell.com

E-mail: pl_support_tech@dell.com

Customer Service Phone 57 95 700

Customer Care 57 95 999

Sales 57 95 999

Customer Service Fax 57 95 806

Reception Desk Fax 57 95 998

Switchboard 57 95 999

Portugal

International Access Code: 00

Country Code: 351

Website: support.euro.dell.com

E-mail: support.euro.dell.com/pt/en/emaildell/

Technical Support 707200149

Customer Care 800 300 413

Sales 800 300 410 or 800 300 411 or 800 300 412 or 21 422 07 10

Fax 21 424 01 12

Puerto Rico General Support 1-800-805-7545

St. Kitts and Nevis General Support toll-free: 1-877-441-4731

St. Lucia General Support 1-800-882-1521

St. Vincent and the Grenadines

General Support toll-free: 1-877-270-4609

Singapore (Singapore)

International Access Code: 005

Country Code: 65

Website: support.ap.dell.com

Technical Support (Dimension, Inspiron, and Electronics and Accessories) toll-free: 1800 394 7430

Technical Support (OptiPlex, Latitude, and Dell Precision) toll-free: 1800 394 7488

Technical Support (PowerApp, PowerEdge, PowerConnect, and PowerVault) toll-free: 1800 394 7478

Customer Service (Penang, Malaysia) 604 633 4949

Transaction Sales toll-free: 1 800 394 7412

Corporate Sales toll-free: 1 800 394 7419

Slovakia (Prague)

International Access Code: 00

Country Code: 421

Website: support.euro.dell.com

E-mail: czech_dell@dell.com

Technical Support 02 5441 5727

Customer Care 420 22537 2707

Fax 02 5441 8328

Tech Fax 02 5441 8328

Switchboard (Sales) 02 5441 7585

South Africa (Johannesburg)

International Access Code:

09/091

Country Code: 27

City Code: 11

Website: support.euro.dell.com

E-mail: dell_za_support@dell.com

Gold Queue 011 709 7713

Technical Support 011 709 7710

Customer Care 011 709 7707

Sales 011 709 7700

Fax 011 706 0495

Switchboard 011 709 7700

Southeast Asian and Pacific Countries

Customer Technical Support, Customer Service, and Sales (Penang, Malaysia)

604 633 4810

Spain (Madrid)

International Access Code: 00

Country Code: 34

City Code: 91

Website: support.euro.dell.com

E-mail: support.euro.dell.com/es/es/emaildell/

Home and Small Business

Technical Support 902 100 130

Customer Care 902 118 540

Sales 902 118 541

Switchboard 902 118 541

Fax 902 118 539

Corporate

Technical Support 902 100 130

Customer Care 902 115 236

Switchboard 91 722 92 00

Fax 91 722 95 83

Sweden (Upplands Vasby)

International Access Code: 00

Country Code: 46

City Code: 8

Website: support.euro.dell.com

E-mail: http://support.euro.dell.com/se/sv/emaildell/

Technical Support 08 590 05 199

Relational Customer Care 08 590 05 642

Home/Small Business Customer Care 08 587 70 527

Employee Purchase Program (EPP) Support 20 140 14 44

Technical Support Fax 08 590 05 594

Sales 08 590 05 185

Switzerland (Geneva) Website: support.euro.dell.com

International Access Code: 00

Country Code: 41

City Code: 22

E-mail: Tech_support_central_Europe@dell.com

E-mail for French-speaking HSB and Corporate Customers: support.euro.dell.com/ch/fr/emaildell/

Technical Support (Home and Small Business) 0844 811 411

Technical Support (Corporate) 0844 822 844

Customer Care (Home and Small Business) 0848 802 202

Customer Care (Corporate) 0848 821 721

Fax 022 799 01 90

Switchboard 022 799 01 01

Taiwan

International Access Code: 002

Country Code: 886

Website: support.ap.dell.com

E-mail: ap_support@dell.com

Technical Support (OptiPlex, Latitude, Inspiron, Dimension, and Electronics and Accessories)

toll-free: 00801 86 1011

Technical Support (PowerApp, PowerEdge, PowerConnect, and PowerVault) toll-free: 00801 60 1256

Transaction Sales toll-free: 00801 65 1228

Corporate Sales toll-free: 00801 651 227

Thailand

International Access Code: 001

Country Code: 66

Website: support.ap.dell.com

Technical Support (OptiPlex, Latitude, and Dell Precision) toll-free: 1800 0060 07

Technical Support (PowerApp, PowerEdge, PowerConnect, and PowerVault) toll-free: 1800 0600 09

Customer Service (Penang, Malaysia) 604 633 4949

Corporate Sales toll-free: 1800 006 009

Transaction Sales toll-free: 1800 006 006

Trinidad/Tobago General Support 1-800-805-8035

Turks and Caicos Islands General Support toll-free: 1-866-540-3355

U.K. (Bracknell)

International Access Code: 00

Country Code: 44

City Code: 1344

Website: support.euro.dell.com

Customer Care website: support.euro.dell.com/uk/en/ECare/Form/Home.asp

E-mail: dell_direct_support@dell.com

Technical Support (Corporate/Preferred Accounts/PAD [1000+ employees]) 0870 908 0500

Technical Support (direct and general) 0870 908 0800

Global Accounts Customer Care 01344 373 186

Home and Small Business Customer Care 0870 906 0010

Corporate Customer Care 01344 373 185

Preferred Accounts (5005000 employees) Customer Care 0870 906 0010

Central Government Customer Care 01344 373 193

Local Government & Education Customer Care 01344 373 199

Health Customer Care 01344 373 194

Home and Small Business Sales 0870 907 4000

Corporate/Public Sector Sales 01344 860 456

Home and Small Business Fax 0870 907 4006

Uruguay General Support toll-free: 000-413-598-2521

U.S.A. (Austin, Texas)

International Access Code: 011

Country Code: 1

Automated Order-Status Service toll-free: 1-800-433-9014

AutoTech (portable and desktop computers) toll-free: 1-800-247-9362

Consumer (Home and Home Office)

Technical Support toll-free: 1-800-624-9896

Customer Service toll-free: 1-800-624-9897

DellNet Service and Support toll-free: 1-877-Dellnet

(1-877-335-5638)

Employee Purchase Program (EPP) Customers toll-free: 1-800-695-8133

Financial Services website: www.dellfinancialservices.com

Financial Services (lease/loans) toll-free: 1-877-577-3355

Financial Services (Dell Preferred Accounts [DPA]) toll-free: 1-800-283-2210

Business

Customer Service and Technical Support toll-free: 1-800-822-8965

Employee Purchase Program (EPP) Customers toll-free: 1-800-695-8133

Printers and Projectors Technical Support toll-free: 1-877-459-7298

Public (government, education, and healthcare)

Customer Service and Technical Support toll-free: 1-800-456-3355

Employee Purchase Program (EPP) Customers toll-free: 1-800-234-1490

Back to Contents Page

Dell Sales toll-free: 1-800-289-3355

or toll-free: 1-800-879-3355

Dell Outlet Store (Dell refurbished computers) toll-free: 1-888-798-7561

Software and Peripherals Sales toll-free: 1-800-671-3355

Spare Parts Sales toll-free: 1-800-357-3355

Extended Service and Warranty Sales toll-free: 1-800-247-4618

Fax toll-free: 1-800-727-8320

Dell Services for the Deaf, Hard-of-Hearing, or Speech-Impaired toll-free: 1-877-DELLTTY

(1-877-335-5889)

U.S. Virgin Islands General Support 1-877-673-3355

Venezuela General Support 8001-3605

Back to Contents Page

Dell PowerEdge 800 Systems Installation and Troubleshooting Guide

Notes, Notices, and Cautions

Abbreviations and Acronyms

For a complete list of abbreviations and acronyms, see the Glossary in your User's Guide.

Information in this document is subject to change without notice. 2004 Dell Inc. All rights reserved.

Reproduction in any manner whatsoever without the written permission of Dell Inc.is strictly forbidden.

Trademarks used in this text: Dell, the DELL logo, PowerEdge, PowerVault, Dell OpenManage, Dimension, Inspiron, OptiPlex, Latitude, Dell Precision, PowerApp, PowerConnect, and DellNet are trademarks of Dell Inc.

Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.

Back to Contents Page

NOTE: A NOTE indicates important information that helps you make better use of your computer.

NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.

CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.

Back to Contents Page

Jumpers, Switches, and Connectors Dell PowerEdge 850 Systems Installation and Troubleshooting Guide

JumpersA General Explanation

System Board Jumpers

System Board Connectors

Riser Card Connectors

Disabling a Forgotten Password

This section provides specific information about the system jumpers. It also provides some basic information on jumpers and switches and describes the connectors on the various boards in the system.

JumpersA General Explanation

Jumpers provide a convenient and reversible way of reconfiguring the circuitry on a printed circuit board. When reconfiguring the system, you may need to change jumper settings on circuit boards or drives.

Jumpers

Jumpers are small blocks on a circuit board with two or more pins emerging from them. Plastic plugs containing a wire fit down over the pins. The wire connects the pins and creates a circuit. To change a jumper setting, pull the plug off its pin(s) and carefully fit it down onto the pin(s) indicated. Figure A-1 shows an example of a jumper.

Figure A-1. Example Jumper

A jumper is referred to as open or unjumpered when the plug is pushed down over only one pin or if there is no plug at all. When the plug is pushed down over two pins, the jumper is referred to as jumpered. The jumper setting is often shown in text as two numbers, such as 12. The number 1 is printed on the circuit board with a triangle so that you can identify each pin number based on the location of pin 1.

Figure A-2 shows the location and default settings of the server-module jumper blocks. See Table A-1 for the designations, default settings, and functions of the jumpers.

System Board Jumpers

Figure A-2 shows the location of the configuration jumpers on the system board. Table A-1 lists the jumper settings.

Figure A-2. System Board Jumpers

Table A-1. System Board Jumper Settings

System Board Connectors

See Figure A-3 and Table A-2 for the location and description of the system board connectors.

Figure A-3. System Board Connectors

Table A-2. System Board Connectors

Riser Card Connectors

The system is available with either a PCIe riser card or a PCI-X/PCIe riser card. See Figure A-4 and Figure A-5 for the location and description of the expansion- card slots on the two riser cards.

Figure A-4. PCIe Riser Card Connectors

Jumper Setting Description

PASSWD_EN (default)

The password feature is enabled.

The password feature is disabled.

NVRAM_CLR (default)

The configuration settings in NVRAM are retained at system boot.

The configuration settings in NVRAM are cleared at next system boot.

jumpered unjumpered

Connector

Description

12V power supply connector

BATTERY Connector for the 3.0 V coin battery

DAUGHTER_CONN1 Connector for the daughter card

DIMMn_ x Memory modules (4)

FAN Power connector for the fans

FRONT_PANEL Control panel interface connector

INTRUSION_SWITCH Connector for the chassis intrusion switch

PRI_IDE1 Optical drive interface connector

PROC Processor socket

PWR_CONN power supply connector

RISER_CONN1 Riser card interface connector

SATA_PORT_n Connectors for the SATA hard drives

USB_CONN Control panel interface connector

Figure A-5. PCI-X/PCIe Riser Card Connectors

Disabling a Forgotten Password

The system's software security features include a system password and a setup password, which are discussed in detail in "Using the System Setup Program" in your User's Guide. The password jumper enables these password features or disables them and clears any password(s) currently in use.

1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2. Open the system. See "Opening the System" in "Troubleshooting Your System."

3. Remove the password jumper plug.

See Figure A-2 to locate the password jumper on the system board.

4. Close the system. See "Closing the System" in "Troubleshooting Your System."

5. Reconnect the system to the electrical outlet, and turn on the system.

The existing passwords are not disabled (erased) until the system boots with the password jumper plug removed. However, before you assign a new system and/or setup password, you must install the jumper plug.

6. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

7. Open the system.

8. Install the password jumper plug.

See Figure A-2 to locate the password jumper on the system board.

9. Close the system, reconnect the system to the electrical outlet, and turn on the system.

10. Assign a new system and/or setup password.

To assign a new password using the System Setup program, see "Using the System Setup Program" in your User's Guide.

Back to Contents Page

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

NOTE: If you assign a new system and/or setup password with the jumper plug still removed, the system disables the new password(s) the next time it boots.

Back to Contents Page

I/O Connectors Dell PowerEdge 850 Systems Installation and Troubleshooting Guide

I/O Connectors

Serial Connector

PS/2-Compatible Keyboard and Mouse Connectors

Video Connector

USB Connector

Integrated NIC Connector

Embedded Remote Access Ethernet Connector

Network Cable Requirements

I/O Connectors

I/O connectors are the gateways that the system uses to communicate with external devices, such as a keyboard, mouse, printer, or monitor. This section describes the various connectors on your system. If you reconfigure the hardware connected to the system, you may also need the pin number and signal information for these connectors. Figure B-1 and Figure B-2 illustrate the connectors on the system front and back panels.

Figure B-1. Front-Panel I/O Connectors

Figure B-2. Back-Panel I/O Connectors

Table B-1 shows the icons used to label the connectors on the system.

Table B-1. I/O Connector Icons

Serial Connector

Serial connectors support devices such as external modems, printers, and mice that require serial data transmission. The serial connector uses a 9-pin D- subminiature connector.

Serial Connector Autoconfiguration

Icon

Connector

Serial connector

Mouse connector

Keyboard connector

Video connector

USB connector

NIC connector

The default designation of the integrated serial connector is COM1. When you add an expansion card containing a serial connector that has the same designation as the integrated connector, the system's autoconfiguration feature remaps (reassigns) the integrated serial connector to the next available designation. Both the new and the remapped COM connectors share the same IRQ setting. COM1 and COM3 share IRQ4, while COM2 and COM4 share IRQ3.

Before adding a card that remaps the COM connectors, check the documentation that came with the software to make sure that the software can accommodate the new COM connector designation.

Figure B-3 illustrates the pin numbers for the serial connector and Table B-2 defines the pin assignments for the connector.

Figure B-3. Serial Connector Pin Numbers

Table B-2. Serial Connector Pin Assignments

PS/2-Compatible Keyboard and Mouse Connectors

The PS/2-compatible keyboard and mouse cables attach to 6-pin, miniature DIN connectors. Figure B-4 illustrates the pin numbers for these connectors and Table B-3 defines the pin assignments for these connectors.

Figure B-4. PS/2-Compatible Keyboard and Mouse Connector Pin Numbers

Table B-3. Keyboard and Mouse Connector Pin Assignments

Video Connector

You can attach a VGA-compatible monitor to the system's integrated video controller using a 15-pin high-density D-subminiature connector. Figure B-5 illustrates the pin numbers for the video connector and Table B-4 defines the pin assignments for the connector.

NOTE: If two COM connectors share an IRQ setting, you may not be able to use them both at the same time. In addition, if you install one or more expansion cards with serial connectors designated as COM1 and COM3, the integrated serial connector is disabled.

Pin

Signal

I/O

Definition

1 DCD I Data carrier detect

2 SIN I Serial input

3 SOUT O Serial output

4 DTR O Data terminal ready

5 GND N/A Signal ground

6 DSR I Data set ready

7 RTS O Request to send

8 CTS I Clear to send

9 RI I Ring indicator

Shell N/A N/A Chassis ground

Pin

Signal

I/O

Definition

1 KBDATA or MFDATA I/O Keyboard data or mouse data

2 NC N/A No connection

3 GND N/A Signal ground

4 FVcc N/A Fused supply voltage

5 KBCLK or MFCLK I/O Keyboard clock or mouse clock

6 NC N/A No connection

Shell N/A N/A Chassis ground

Figure B-5. Video Connector Pin Numbers

Table B-4. Video Connector Pin Assignments

USB Connector

The system's USB connector supports USB-compliant peripherals such as keyboards, mice, and printers and may also support USB-compliant devices such as diskette drives and CD drives. Figure B-6 illustrates the pin numbers for the USB connector and Table B-5 defines the pin assignments for the connector.

Figure B-6. USB Connector Pin Numbers

Table B-5. USB Connector Pin Assignments

Integrated NIC Connector

The system's integrated NIC functions as a separate network expansion card while providing fast communication between servers and workstations. Figure B- 7 illustrates the pin numbers for the NIC connectors and Table B-6 defines the pin assignments for the connectors.

Figure B-7. NIC Connector

NOTE: Installing a video card automatically disables the system's integrated video controller.

Pin

Signal

I/O

Definition

1 RED O Red video

2 GREEN O Green video

3 BLUE O Blue video

4 NC N/A No connection

58, 10 GND N/A Signal ground

9 VCC N/A Vcc

11 NC N/A No connection

12 DDC data out O Monitor detect data

13 HSYNC O Horizontal synchronization

14 VSYNC O Vertical synchronization

15 DDC CLK I/O Monitor detect clock

NOTICE: Do not attach a USB device or a combination of USB devices that draw a maximum current of more than 500 mA per channel or +5 V. Attaching devices that exceed this threshold may cause the USB connectors to shut down. See the documentation that accompanied the USB devices for their maximum current ratings.

Pin

Signal

I/O

Definition

1 Vcc N/A Supply voltage

2 DATA I Data in

3 +DATA O Data out

4 GND N/A Signal ground

Table B-6. NIC Connector Pin Assignments

Embedded Remote Access Ethernet Connector

The system's optional embedded remote access (ERA) circuitry is designed to provide remote access capabilities for the system. It is designed specifically to work with systems management software. Figure B-8 illustrates the pin numbers for the ERA connector and Table B-7 defines the pin assignments for the connector.

Figure B-8. Embedded Remote Access Ethernet Connector

Table B-7. ERA Ethernet Connector Pin Assignments

Network Cable Requirements

The NIC supports a UTP Ethernet cable equipped with a standard RJ45-compatible plug. Observe the following cabling restrictions.

l Use Category 5 or greater wiring and connectors.

l Do not exceed a cable run length (from a workstation to a hub) of 100 m (328 ft).

For detailed guidelines on operation of a network, see "Systems Considerations of Multi-Segment Networks" in the IEEE 802.3 standard.

Back to Contents Page

Pin

Signal

I/O

Definition

1 TD+ O Data out (+)

2 TD O Data out ()

3 RD+ I Data in (+)

4 NC N/A No connection

5 NC N/A No connection

6 RD I Data in ()

7 NC N/A No connection

8 NC N/A No connection

Pin

Signal

I/O

Definition

1 TD+ O Data out (+)

2 TD O Data out ()

3 RD+ I Data in (+)

4 NC N/A No connection

5 NC N/A No connection

6 RD I Data in ()

7 NC N/A No connection

8 NC N/A No connection

NOTICE: To avoid line interference, voice and data lines must be in separate sheaths.

Back to Contents Page

Introduction Dell PowerEdge 850 Systems Installation and Troubleshooting Guide

Other Information You May Need

Your system includes the following significant service and upgrade features:

l Baseboard Management Controller (BMC), which monitors temperatures and voltages throughout the system and notifies you if the system overheats, if a system cooling fan malfunctions, or if a power supply fails. The BMC supports the industry-standard Intelligent Platform Management Interface (IPMI) specification.

l System diagnostics, which checks for hardware problems (if the system can boot).

The following system options are offered:

l Additional system memory

l A variety of PCI-X and PCIe expansion-card options (including RAID controller cards)

l IDE optical drive

l Additional hard drives

Other Information You May Need

l The Rack Installation Guide or Rack Installation Instructions included with your rack solution describes how to install your system into a rack.

l The Getting Started Guide provides an overview of initially setting up your system.

l The User's Guide provides information about system features and technical specifications.

l CDs included with your system provide documentation and tools for configuring and managing your system.

l Systems management software documentation describes the features, requirements, installation, and basic operation of the software.

l Operating system documentation describes how to install (if necessary), configure, and use the operating system software.

l Documentation for any components you purchased separately provides information to configure and install these options.

l Updates are sometimes included with the system to describe changes to the system, software, and/or documentation.

l Release notes or readme files may be included to provide last-minute updates to the system or documentation or advanced technical reference material intended for experienced users or technicians.

Back to Contents Page

The Product Information Guide provides important safety and regulatory information. Warranty information may be included within this document or as a separate document.

NOTE: Always check for updates on support.dell.com and read the updates first because they often supersede information in other documents.

Back to Contents Page

Indicators, Messages, and Codes Dell PowerEdge 850 Systems Installation and Troubleshooting Guide

Front-Panel Features

Back-Panel Features

NIC Indicators

System Messages

Diagnostics Indicator Codes

System Beep Codes

Warning Messages

Diagnostics Messages

Alert Messages

Baseboard Management Controller Messages

The system, applications, and operating systems can identify problems and alert you to them. Any of the following can indicate when the system is not operating properly:

l System indicators

l System messages

l Beep codes

l Warning messages

l Diagnostics messages

l Alert messages

This section describes each type of message, lists the possible causes, and provides steps to resolve any problems indicated by a message. The system indicators and features are illustrated in this section.

Front-Panel Features

Figure 2-1 shows the controls, indicators, and connectors located behind the optional bezel on the front-panel. (To remove the optional bezel and access the front panel, press the latch at the left end of the bezel. See "Opening the System" in "Troubleshooting Your System" for detailed instructions on removing the bezel.) Table 2-1 describes the front-panel indicators, buttons, and connectors.

Figure 2-1. Front-Panel Features

The optional locking system bezel incorporates blue and amber system status indicators. The blue indicator lights up when the system is operating correctly.

Table 2-1. Front-Panel LED Indicators, Buttons, and Connectors

Feature

Icon

Description

System status indicator

The blue system status indicator lights up during normal system operation.

The amber system status indicator flashes when the system needs attention due to a system problem.

Back-Panel Features

Figure 2-2 shows the back-panel features of the system.

Figure 2-2. Back-Panel Features

NIC Indicators

Figure 2-3. NIC Indicators

System identification button

You can use the system identification buttons on the front and back panels to locate a particular system within a rack. When one of these buttons is pushed, the blue system status indicators on the front and back panels blink until one of the buttons is pushed again.

You can also use the systems management software to cause the indicators to flash to identify a particular system.

Hard-drive indicator

The green hard-drive activity indicator flashes when the SATA hard drives are in use.

NOTE: This indicator does not flash when SCSI hard drives are in use.

NMI button

The NMI button is used to troubleshoot software and device driver errors when using certain operating systems. This button can be pressed using the end of a paper clip. Use this button only if directed to do so by qualified support personnel or by the operating system's documentation.

USB connectors

Connect USB 2.0-compliant devices to the system.

Video connector

Connects a monitor to the system.

Power-on indicator,

Power button

The power button turns system power off and on.

NOTICE: If you turn off the system using the power button and the system is running an ACPI-compliant operating system, the system can perform an orderly shutdown before power is turned off. If the power button is pressed for more than 4 seconds, the system power will turn off regardless of the current operating system state. If the system is not running an ACPI-compliant operating system, power is turned off immediately after the power button is pressed.

The power button is enabled in the System Setup program. When disabled, the button can only turn the system power on. For more information, see "Using the System Setup Program" in your User's Guide.

The power-on indicator lights or blinks to indicate the status of power to the system.

The power-on indicator lights when the system is on. The indicator is off when the system is off and power is disconnected from the system. The indicator blinks when the system is off but is connected to the power source.

Diagnostic indicators (4)

The diagnostic indicators aid in troubleshooting the system. For more information, see "Diagnostics Indicator Codes."

Table 2-2. NIC Indicators

System Messages

System messages appear on the screen to notify you of a possible problem with the system. Table 2-3 lists the system messages that can occur and the probable cause and corrective action for each message.

Table 2-3. System Messages

Indicator Type

Indicator Code

Description

Activity Off When off at the same time that the link indicator is off, the NIC is not connected to the network or the NIC is disabled by the System Setup program. See "Using the System Setup Program" in the User's Guide.

Blinking Indicates that network data is being sent or received.

Link Off When off at the same time that the activity indicator is off, the NIC is not connected to the network or the NIC is disabled by the System Setup program. See "Using the System Setup Program" in the User's Guide.

Green Network connection is present.

NOTE: If you receive a system message that is not listed in Table 2-3, check the documentation for the application that is running when the message appears or the operating system's documentation for an explanation of the message and recommended action.

Message

Causes

Corrective Actions

Amount of available memory limited to

256MB

The OS Install Mode option in the System Setup program is set to On. This limits the amount of available memory to 256 MB because some operating systems will not complete installation with more than 2 GB of system memory.

After the operating system is installed, enter the System Setup program and set the OS Install Mode option to Off. See your User's Guide for details.

Attempting to update Remote

Configuration. Please wait....

Remote Configuration is in progress. Wait until the process is complete.

BIOS Update Attempt Failed! Remote BIOS update attempt failed. Retry the BIOS update. If the problem persists, see "Getting Help."

Caution! NVRAM_CLR jumper is installed

on system board.

NVRAM_CLR jumper is installed. Check the System Setup configuration settings. See "Using the System Setup Program" in your User's Guide. Remove the NVRAM_CLR jumper. See Figure A-2 for jumper locations.

Data error The diskette drive or hard drive cannot read the data.

For the operating system, run the appropriate utility to check the file structure of the diskette drive or hard drive.

See your operating system documentation for information on running these utilities.

Decreasing available memory One or more memory modules might be improperly seated or faulty.

Reinstall the memory modules and, if necessary, replace them. See "System Memory" in "Installing System Components."

See "Troubleshooting System Memory" in "Troubleshooting Your System."

Diskette read failure Faulty or improperly inserted diskette. Replace the diskette.

Diskette subsystem reset failed Faulty diskette drive or optical drive controller. Ensure that the diskette drive and optical drive cables are properly connected. See "Troubleshooting a USB Device" and "Troubleshooting an Optical Drive" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

Drive not ready Diskette missing or improperly inserted in diskette drive.

Reinsert or replace the diskette.

Error: Incorrect memory configuration.

Ensure memory in slots DIMM1_A and

DIMM1_B, DIMM2_A and DIMM2_B match

identically in size, speed and rank.

The installed memory modules are not matched pairs.

See "Memory Module Installation Guidelines" in "Installing System Components."

Error: Remote Access Controller

initialization failure.

Faulty or improperly installed RAC. Ensure that the RAC is properly installed. See "Troubleshooting Expansion Cards" in "Troubleshooting Your System."

Error 8602: Auxiliary device failure.

Verify that mouse and keyboard are

securely attached to correct

connectors.

Loose or improperly connected mouse or keyboard cable; faulty mouse or keyboard.

Replace the mouse. If the problem persists, replace the keyboard.

Gate A20 failure Faulty keyboard controller (faulty system board). See "Getting Help."

General failure The operating system is unable to carry out the command.

This message is usually followed by specific information. Take the appropriate action to resolve the problem.

IDE Primary drive 0 not found Primary drive 0 set as Auto, no disk. Run the System Setup program to correct the settings. See "Using the System Setup Program" in your User's Guide.

Invalid memory configuration detected.

Potential for data corruption exists!

Unsupported DIMMs are installed in the system, or the memory configuration is incorrect.

Replace or reconfigure the DIMMs. See "System Memory" in "Installing System Components" for memory configuration guidelines, a list of supported DIMMs, and supported memory configurations.

Keyboard controller failure Faulty keyboard controller (faulty system board). See "Getting Help."

Keyboard data line failure

Keyboard failure

Keyboard stuck key failure

Loose or improperly connected keyboard cable; faulty keyboard; faulty keyboard controller.

Ensure that the keyboard is properly connected. If the problem persists, replace the keyboard. If the problem persists, see "Getting Help."

Keyboard fuse has failed. Keyboard fuse has failed. Replace the keyboard.

Faulty system board. If the problem persists, the system board is faulty. See "Getting Help."

Manufacturing mode detected System is incorrectly configured.

Memory address line failure at address,

read value expecting value

Memory double word logic failure at

address, read value expecting value

Memory odd/even logic failure at start

address to end address

Memory write/read failure at address,

read value expecting value

Faulty or improperly installed memory modules, or faulty system board.

Ensure that all memory modules are properly installed. See "Troubleshooting System Memory" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

Memory tests terminated by keystroke The spacebar was pressed during POST to terminate the memory test.

Information only.

No boot device available The system cannot find the diskette or hard drive.

If the diskette drive is your boot device, ensure that a bootable disk is in the drive.

If the hard drive is your boot device, ensure that the hard drive is installed, properly seated, and partitioned as a boot device.

Enter the System Setup program and verify the boot sequence information. See your User's Guide for details.

No boot sector on hard-disk drive The system configuration information in the System Setup program might be incorrect.

Enter the System Setup program and verify the system configuration information for the hard drive. See your User's Guide for details.

If the message continues to appear after verifying the information in the System Setup program, the operating system might have been corrupted. Reinstall the operating system. See your operating system documentation for reinstallation information.

No timer tick interrupt A chip on the system board might be malfunctioning.

Run the system diagnostics. See "Running the System Diagnostics."

Not a boot diskette The operating system is trying to boot from a diskette that does not have a bootable operating system installed on it.

Insert a diskette that has a bootable operating system.

PCI BIOS failed to install PCI device BIOS (Option ROM) checksum failure is detected during shadowing.

Ensure that all appropriate cables are securely connected to the expansion cards. If the problem persists, see "Troubleshooting Expansion Cards" in "Troubleshooting Your System."

PCIe Degraded Link Width Error:

Embedded Bus#nn/Dev#nn/Funcn

Expected Link Width is n

Actual Link Width is n

Faulty or improperly installed PCIe card. Reseat the PCIe cards. See "Expansion Cards" in "Installing System Components." If the problem persists, see "Getting Help."

PCIe Degraded Link Width Error: Slot n

Expected Link Width is n

Actual Link Width is n

Faulty or improperly installed PCIe card in the specified slot number.

Reseat the PCIe card in the specified slot number. See "Expansion Cards" in "Installing System Components." If the problem persists, see "Getting Help."

PCIe Training Error: Embedded

Bus#nn/Dev#nn/Funcn

Faulty or improperly installed PCIe card. Reseat the PCIe cards. See "Expansion Cards" in "Installing System Components." If the problem persists, see "Getting Help."

PCIe Training Error: Slot n Faulty or improperly installed PCIe card in the specified slot number.

Reseat the PCIe card in the specified slot number. See "Expansion Cards" in "Installing System Components." If the

Diagnostics Indicator Codes

The four diagnostics indicators on the system front panel display error codes during system startup. Table 2-4 lists the causes and possible corrective actions associated with these codes.

problem persists, see "Getting Help."

Plug & Play Configuration Error Error encountered in initializing PCI device; faulty system board.

Install the NVRAM_CLR jumper and reboot the system. See Figure A-2 for jumper location. Check for a BIOS update. If the problem persists, see "Troubleshooting Expansion Cards" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

Primary drive 0/1 configuration error Faulty drive. Parameters failure. Ensure that the hard drive cables are properly connected. See "Troubleshooting SCSI Hard Drives" in "Troubleshooting Your System."

Primary drive 0/1 failure Faulty drive. INT13 call failure from the drive. Ensure that the hard drive cables are properly connected. See "Troubleshooting SCSI Hard Drives" in "Troubleshooting Your System."

Read fault

Requested sector not found

The operating system cannot read from the diskette or hard drive, the system could not find a particular sector on the disk, or the requested sector is defective.

Replace the diskette. Ensure that the diskette and hard-drive cables are properly connected. See "Troubleshooting a USB Device," "Troubleshooting SATA Hard Drives," or "Troubleshooting SCSI Hard Drives" in "Troubleshooting Your System" for the appropriate drive(s) installed in your system.

Remote Configuration update attempt

failed

System could not implement Remote Configuration request.

Retry Remote Configuration.

ROM bad checksum = address Faulty or improperly installed expansion card. Remove and reseat the expansion cards. See "Troubleshooting Expansion Cards" in "Troubleshooting Your System."

SATA port 0/1 hard disk drive

configuration error

Faulty drive. Parameters failure. Ensure that the hard drive cables are properly connected. See "Troubleshooting SATA Hard Drives" in "Troubleshooting Your System."

SATA port 0/1 hard disk drive failure

SATA port 0/1 hard disk drive auto-

sensing error

Faulty drive. INT13 call failure from the drive. Ensure that the hard drive cables are properly connected. See "Troubleshooting SATA Hard Drives" in "Troubleshooting Your System."

SATA Port 0/1 hard disk not found SATA Port0/1 set as Auto, no disk installed. Run the System Setup program to correct the settings. See "Using the System Setup Program" in your User's Guide.

Sector not found

Seek error

Seek operation failed

Faulty diskette or hard drive. See "Troubleshooting a USB Device," "Troubleshooting SATA Hard Drives," or "Troubleshooting SCSI Hard Drives" in "Troubleshooting Your System" for the appropriate drive installed in your system.

Shutdown failure Shutdown test failure. Ensure that all memory modules are properly installed. See "Troubleshooting System Memory" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

The amount of system memory has

changed.

Faulty memory module. Information only, if you have changed the memory configuration.

See "Troubleshooting System Memory" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

The amount of tested memory is below

the minimum system configuration.

System halted!

Invalid memory configuration. See "Memory Module Installation Guidelines" in "Installing System Components."

Faulty memory module. See "Troubleshooting System Memory" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

Time-of-day clock stopped Faulty battery; faulty system board. See "Troubleshooting the System Battery" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

Time-of-day not set - please run SETUP

program

Incorrect Time or Date settings; faulty system battery.

Check the Time and Date settings. See "Using the System Setup Program" in your User's Guide. If the problem persists, see "Troubleshooting the System Battery" in "Troubleshooting Your System."

Timer chip counter 2 failed Faulty system board. See "Getting Help."

Unexpected interrupt in protected mode Faulty or improperly installed memory modules or faulty system board.

Ensure that all memory modules are properly installed. See "Memory Module Installation Guidelines" in "Installing System Components." If the problem persists, see "Troubleshooting System Memory" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

Utility partition not available Utility partition is not available on the hard disk Create a utility partition on the boot hard drive. See the CDs that came with your system.

Warning! No micro code update loaded

for processor 0

Micro code update failed. Update the BIOS firmware. See "Getting Help."

Write fault

Write fault on selected drive

Faulty diskette, diskette drive, hard drive. Replace the diskette. Ensure that the diskette drive and hard-drive cables are properly connected. See "Troubleshooting a USB Device," "Troubleshooting SATA Hard Drives," or "Troubleshooting SCSI Hard Drives" in "Troubleshooting Your System" for the appropriate drive(s) installed in your system.

Table 2-4. Diagnostic Indicator Codes

Code

Causes

Corrective Action

Possible processor failure. See "Troubleshooting the Microprocessor" in "Troubleshooting Your System."

Memory failure. See "Troubleshooting System Memory" in "Troubleshooting Your System."

Possible expansion card failure.

See "Troubleshooting Expansion Cards" in "Troubleshooting Your System."

Possible video card failure. See "Troubleshooting Expansion Cards" in "Troubleshooting Your System."

Diskette drive or hard drive failure. Ensure that the diskette drive and hard-drive are properly connected. See "Installing Drives" for information on the drives installed in your system.

Possible USB failure.

See "Troubleshooting a USB Device" in "Troubleshooting Your System."

No memory modules detected.

See "Troubleshooting System Memory" in "Troubleshooting Your System."

System board failure.

See "Getting Help."

Memory configuration error.

See "Troubleshooting System Memory" in "Troubleshooting Your System."

Possible system board resource and/or system board hardware failure.

See "Troubleshooting IRQ Assignment Conflicts" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

Possible expansion card failure. See "Troubleshooting Expansion Cards" in "Troubleshooting Your System."

Other failure.

Ensure that the diskette drive, optical drive, and hard drives are properly connected. See "Troubleshooting Your System" for the appropriate drive installed in your system.

If the problem persists, see "Getting Help."

The system is in a normal operating condition after POST.

Information only.

System Beep Codes

If an error that cannot be reported on the screen occurs during POST, the system may emit a series of beeps that identifies the problem.

If a beep code is emitted, write down the series of beeps and then look it up in Table 2-5. If you are unable to resolve the problem by looking up the meaning of the beep code, use system diagnostics to identify the possible cause. If you are still unable to resolve the problem, see "Getting Help."

Table 2-5. System Beep Codes

Warning Messages

NOTE: If the system boots without a keyboard, mouse, or monitor attached, the system does not issue beep codes related to those peripherals.

Code

Cause

Corrective Action

1-1-2 CPU register test failure See "Troubleshooting the Microprocessor" in "Troubleshooting Your System."

1-1-3 CMOS write/read failure; faulty system board Faulty system board. See "Getting Help."

1-1-4 BIOS error Reflash the BIOS.

1-2-1 Programmable interval-timer failure; faulty system board

Faulty system board. See "Getting Help."

1-2-2 DMA initialization failure See "Troubleshooting System Memory" in "Troubleshooting Your System."

1-2-3 DMA page register write/read failure

1-3-1 Main-memory refresh verification failure

1-3-2 No memory installed

1-3-3 Chip or data line failure in the first 64 KB of main memory

1-3-4 Odd/even logic failure in the first 64 KB of main memory

1-4-1 Address line failure in the first 64 KB of main memory

1-4-2 Parity failure in the first 64 KB of main memory

1-4-3 Fail-safe timer test failure

1-4-4 Software NMI port test failure

2-1-1 through 2-4-4

Bit failure in the first 64 KB of main memory

3-1-1 Slave DMA-register failure Faulty system board. See "Getting Help."

3-1-2 Master DMA-register failure

3-1-3 Master interrupt-mask register failure

3-1-4 Slave interrupt-mask register failure

3-2-2 Interrupt vector loading failure

3-2-4 Keyboard-controller test failure

3-3-1 CMOS failure

3-3-2 System configuration check failure

3-3-3 Keyboard controller not detected

3-3-4 Video memory test failure

3-4-1 Screen initialization failure

3-4-2 Screen-retrace test failure

3-4-3 Video ROM search failure

4-2-1 No timer tick Faulty system board. See "Getting Help."

4-2-2 Shutdown test failure

4-2-3 Gate A20 failure

4-2-4 Unexpected interrupt in protected mode See "Troubleshooting Expansion Cards" in "Troubleshooting Your System."

4-3-1 Improperly installed or faulty memory modules See "Troubleshooting System Memory" in "Troubleshooting Your System."

4-3-2 No memory modules installed in the first memory module connector

Install a memory module in the first memory module connector. See "System Memory" in "Installing System Components."

4-3-3 Faulty system board Faulty system board. See "Getting Help."

4-3-4 Time-of-day clock stopped See "Troubleshooting System Memory" in "Troubleshooting Your System." If the problem persists, see "Getting Help."

4-4-1 Super I/O chip failure; faulty system board Faulty system board. See "Getting Help."

4-4-4 Cache test failure; faulty processor See "Troubleshooting the Microprocessor" in "Troubleshooting Your System."

A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before you format a diskette, a message will warn you that you may lose all data on the diskette. Warning messages usually interrupt the task and require you to respond by typing y (yes) or n (no).

Diagnostics Messages

When you run system diagnostics, an error message may result. Diagnostic error messages are not covered in this section. Record the message on a copy of the Diagnostics Checklist in "Getting Help," and then follow the instructions in that section for obtaining technical assistance.

Alert Messages

Systems management software generates alert messages for your system. Alert messages include information, status, warning, and failure messages for drive, temperature, fan, and power conditions. For more information, see the systems management software documentation.

Baseboard Management Controller Messages

The Baseboard Management Controller (BMC) enables you to configure, monitor, and recover systems remotely. BMC uses the system's serial port and integrated NIC1 to support fault logging and SNMP alerting.

For additional information on using BMC, see the documentation for the BMC and systems management applications.

Back to Contents Page

NOTE: Warning messages are generated by either the application or the operating system. For more information, see the documentation that accompanied the operating system or application.

NOTE: If the integrated network controller is used in an Ether Channel team or link aggregation team, the BMC management traffic will not function properly. For more information about network teaming, see the documentation for the network controller.

Back to Contents Page

Running the System Diagnostics Dell PowerEdge 850 Systems Installation and Troubleshooting Guide

Using Server Administrator Diagnostics

System Diagnostics Features

When to Use the System Diagnostics

Running the System Diagnostics

System Diagnostics Testing Options

Using the Custom Test Options

If you experience a problem with your system, run the diagnostics before calling for technical assistance. The purpose of the diagnostics is to test your system's hardware without requiring additional equipment or risking data loss. If you are unable to fix the problem yourself, service and support personnel can use diagnostics test results to help you solve the problem.

Using Server Administrator Diagnostics

To assess a system problem, first use the online Server Administrator diagnostics. If you are unable to identify the problem, then use the system diagnostics.

To access the online diagnostics, log into the Server Administrator home page, and then click the Diagnostics tab. For information about using diagnostics, see the online help. For additional information, see the Server Administrator User's Guide.

System Diagnostics Features

The system diagnostics provides a series of menus and options for particular device groups or devices. The system diagnostics menus and options allow you to:

l Run tests individually or collectively.

l Control the sequence of tests.

l Repeat tests.

l Display, print, or save test results.

l Temporarily suspend testing if an error is detected or terminate testing when a user-defined error limit is reached.

l View help messages that briefly describe each test and its parameters.

l View status messages that inform you if tests are completed successfully.

l View error messages that inform you of problems encountered during testing.

When to Use the System Diagnostics

If a major component or device in the system does not operate properly, component failure may be indicated. As long as the microprocessor and the system's input/output devices (monitor, keyboard, and diskette drive) are functioning, you can use the system diagnostics to help identify the problem.

Running the System Diagnostics

The system diagnostics is run from the utility partition on your hard drive.

1. As the system boots, press during POST.

2. From the utility partition main menu, select Run System Diagnostics, or select Run Memory Diagnostics if you are troubleshooting memory.

When you start the system diagnostics, a message is displayed stating that the diagnostics are initializing. Next, the Diagnostics menu appears. The menu allows you to run all or specific diagnostics tests or to exit the system diagnostics.

System Diagnostics Testing Options

NOTICE: Use the system diagnostics to test only your system. Using this program with other systems may cause invalid results or error messages. In addition, use only the program that came with your system (or an updated version of that program).

NOTE: Before you read the rest of this section, start the system diagnostics so that you can see the utility on your screen.

Click the testing option in the Main Menu window. Table 3-1 provides a brief explanation of testing options.

Table 3-1. System Diagnostics Testing Options

Using the Custom Test Options

When you select Custom Test in the Main Menu window, the Customize window appears and allows you to select the device(s) to be tested, select specific options for testing, and view the test results.

Selecting Devices for Testing

The left side of the Customize window listsdevices that can be tested. Devices are grouped by device type or by module, depending on the option you select. Click the (+) next to a device or module to view its components. Click (+) on any component to view the tests that are available. Clicking a device, rather than its components, selects all of the components of the device for testing.

Selecting Diagnostics Options

Use the Diagnostics Options area to select how you want to test a device. You can set the following options:

l Non-Interactive Tests Only When checked, runs only tests that require no user intervention.

l Quick Tests Only When checked, runs only the quick tests on the device. Extended tests will not run when you select this option.

l Show Ending Timestamp When checked, time stamps the test log.

l Test Iterations Selects the number of times the test is run.

l Log output file pathname When checked, enables you to specify where the test log file is saved.

Viewing Information and Results

The tabs in the Customize window provide information about the test and the test results. The following tabs are available:

l Results Displays the test that ran and the result.

l Errors Displays any errors that occurred during the test.

l Help Displays information about the currently selected device, component, or test.

l Configuration Displays basic configuration information about the currently selected device.

l Parameters If applicable, displays parameters that you can set for the test.

Back to Contents Page

Testing Option

Function

Express Test Performs a quick check of the system. This option runs device tests that do not require user interaction. Use this option to quickly identify the source of your problem.

Extended Test Performs a more thorough check of the system. This test can take an hour or longer.

Custom Test Tests a particular device.

Information Displays test results.

Back to Contents Page

Troubleshooting Your System Dell PowerEdge 850 Systems Installation and Troubleshooting Guide

Safety FirstFor You and Your System

Start-Up Routine

Checking the Equipment

Responding to a Systems Management Software Alert Message

Inside the System

Opening the System

Closing the System

Troubleshooting a Wet System

Troubleshooting a Damaged System

Troubleshooting the System Battery

Troubleshooting the Power Supply

Troubleshooting System Cooling Problems

Troubleshooting System Memory

Troubleshooting an Optical Drive

Troubleshooting SCSI Hard Drives

Troubleshooting SATA Hard Drives

Troubleshooting a RAID Controller Card

Troubleshooting Expansion Cards

Troubleshooting the Microprocessor

Safety FirstFor You and Your System

To perform certain procedures in this document, you must remove the system cover and work inside the system. While working inside the system, do not attempt to service the system except as explained in this guide and elsewhere in your system documentation.

Start-Up Routine

Look and listen during the system's start-up routine for the indications described in Table 4-1.

Table 4-1. Start-Up Routine Indications

Checking the Equipment

This section provides troubleshooting procedures for external devices attached to the system, such as the monitor, keyboard, or mouse. Before you perform any of the procedures, see "Troubleshooting External Connections."

Troubleshooting IRQ Assignment Conflicts

Most PCI devices can share an IRQ with another device, but they cannot use an IRQ simultaneously. To avoid this type of conflict, see the documentation for

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

Look/listen for:

Action

An error message displayed on the monitor. See "System Messages" in "Indicators, Messages, and Codes."

A series of beeps emitted by the system. See "System Beep Codes" in "Indicators, Messages, and Codes."

Alert messages from the systems management software. See the systems management software documentation.

The monitor's power indicator. See "Troubleshooting the Video Subsystem."

The keyboard indicators. See "Troubleshooting the Keyboard."

The USB diskette drive activity indicator. See "Troubleshooting a USB Device."

The USB CD drive activity indicator. See "Troubleshooting a USB Device."

The optical drive activity indicator. See "Troubleshooting an Optical Drive."

The hard-drive activity indicator. See "Troubleshooting SCSI Hard Drives."

An unfamiliar constant scraping or grinding sound when you access a drive. See "Getting Help."

each PCI device for specific IRQ requirements. Table 4-2 lists the IRQ assignments.

Table 4-2. IRQ Assignment Defaults

Troubleshooting External Connections

Loose or improperly connected cables are the most likely source of problems for the system, monitor, and other peripherals (such as a printer, keyboard, mouse, or other external device). Ensure that all external cables are securely attached to the external connectors on your system. See Figure B-1 for the front- panel connectors and Figure B-2 for the back-panel connectors on your system.

Troubleshooting the Video Subsystem

Problem

l Monitor is not working properly.

l Video memory is faulty.

Action

1. Check the system and power connections to the monitor.

2. Determine whether the system has monitors attached to both the front and rear video connectors.

The system supports only one monitor attached to either the front or rear video connector. When a monitor is connected to the front panel, the back- panel video, and PS/2 keyboard and mouse connectors are disabled.

If two monitors are attached to the system, disconnect one monitor. If the problem is not resolved, continue to the next step.

3. Check the system and power connections to the monitor.

4. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

If the tests run successfully, the problem is not related to video hardware.

If the tests fail, see "Getting Help."

Troubleshooting the Keyboard

Problem

l System message indicates a problem with the keyboard.

IRQ Line

Assignment

IRQ0 System timer

IRQ1 Keyboard controller

IRQ2 Interrupt controller 1 to enable IRQ8 through IRQ15

IRQ3 Available

IRQ4 Serial port 1 (COM1 and COM3)

IRQ5 Available

IRQ6 Available

IRQ7 Available

IRQ8 Real-time clock

IRQ9 ACPI functions (used for power management)

IRQ10 Available

IRQ11 Available

IRQ12 PS/2 mouse port (available if the mouse is disabled through the System Setup program)

IRQ13 Math coprocessor

IRQ14 IDE optical drive controller (available if IDE CDROM controller is disabled through the System Setup program)

IRQ15 Reserved (available if IDE CDROM controller is disabled through the System Setup program)

l Keyboard is not functioning properly.

Action

1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

2. Press each key on the keyboard, and examine the keyboard and its cable for signs of damage.

3. Swap the faulty keyboard with a working keyboard.

If the problem is resolved, replace the faulty keyboard. See "Getting Help."

If the problem is not resolved, see "Getting Help."

Troubleshooting the Mouse

Problem

l System message indicates a problem with the mouse.

l Mouse is not functioning properly.

Action

1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

If the test fails, continue to the next step.

2. Examine the mouse and its cable for signs of damage.

3. Swap the faulty mouse with a working mouse.

If the problem is resolved, replace the faulty mouse. See "Getting Help."

If the problem is not resolved, see "Getting Help."

Troubleshooting Basic I/O Functions

Problem

l Error message indicates a problem with a serial port.

l Device connected to a serial port is not operating properly.

Action

1. Enter the System Setup program and ensure that the serial port is enabled. See "Using the System Setup Program" in the User's Guide.

2. If the problem is confined to a particular application, see the application documentation for specific port configuration requirements that the program may require.

3. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

If the tests run successfully but the problem persists, see "Troubleshooting a Serial I/O Device."

Troubleshooting a Serial I/O Device

Problem

l Device connected to the serial port is not operating properly.

Action

1. Turn off the system and any peripheral devices connected to the serial port.

2. Swap the serial interface cable with a working cable, and turn on the system and the serial device.

If the problem is resolved, replace the interface cable. See "Getting Help."

3. Turn off the system and the serial device, and swap the device with a comparable device.

4. Turn on the system and the serial device.

If the problem is resolved, replace the serial device. See "Getting Help."

If the problem persists, see "Getting Help."

Troubleshooting a USB Device

Problem

l System message indicates a problem with a USB device.

l Device connected to a USB port is not operating properly.

Action

1. Enter the System Setup program, and ensure that the USB ports are enabled. See "Using the System Setup Program" in your User's Guide.

2. Turn off the system and any USB devices.

3. Disconnect the USB devices, and connect the malfunctioning device to the other USB connector.

4. Turn on the system and the reconnected device.

If the problem is resolved, the USB connector might be defective. See "Getting Help."

5. If possible, swap the interface cable with a working cable.

If the problem is resolved, replace the interface cable. See "Getting Help."

6. Turn off the system and the USB device, and swap the device with a comparable device.

7. Turn on the system and the USB device.

If the problem is resolved, replace the USB device. See "Getting Help."

If the problem persists, see "Getting Help."

Troubleshooting a NIC

Problem

l NIC cannot communicate with network.

Action

1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

2. Check the appropriate indicator on the NIC connector. See "NIC Indicators" in "Indicators, Messages, and Codes."

l If the link indicator does not light, check all cable connections.

l If the activity indicator does not light, the network driver files might be damaged or missing.

Remove and reinstall the drivers if applicable. See the NIC's documentation.

l Change the autonegotiation setting, if possible.

l Use another connector on the switch or hub.

If you are using a NIC card instead of an integrated NIC, see the documentation for the NIC card.

3. Ensure that the appropriate drivers are installed and the protocols are bound. See the NIC's documentation.

4. Enter the System Setup program and confirm that the NICs are enabled. See "Using the System Setup Program" in your User's Guide.

5. Ensure that the NICs, hubs, and switches on the network are all set to the same data transmission speed. See the network equipment documentation.

6. Ensure that all network cables are of the proper type and do not exceed the maximum length. See "Network Cable Requirements" in "I/O Connectors."

Responding to a Systems Management Software Alert Message

Systems management software monitors critical system voltages and temperatures, fans, and hard drives in the system. Alert messages appear in the Alert Log window. For information about the Alert Log window, see the systems management software documentation.

Inside the System

In Figure 4-1, the bezel and system cover are removed to provide an interior view of the system.

Figure 4-1. Inside the System

The system board holds the system's control circuitry and other electronic components. The processor and memory are installed directly on the system board. Using a riser card, the system can accommodate two expansion cards. The peripheral bays provide space for up to two hard drives and an optional optical drive. Power is supplied to the system board and drives through one nonredundant power supply.

Opening the System

The system is enclosed by an optional bezel and cover. To upgrade or troubleshoot the system, remove the bezel and cover.

1. If applicable, remove the bezel. See Figure 4-2.

a. Unlock the bezel.

b. Unlatch the left end of the bezel and rotate it away from the front panel.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

c. Unhook the right end of the bezel and pull the bezel away from the system.

Figure 4-2. Installing and Removing the Optional Bezel

2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet and peripherals.

3. Remove the system from the rack and place it on a work surface.

4. To remove the system cover, loosen the thumbscrew at the back of the system. See Figure 4-3.

5. Slide the cover backward about 1.3 cm (0.5 inch), and grasp the cover on both sides.

6. Carefully lift the cover away from the system.

Figure 4-3. Installing and Removing the System Cover

Closing the System

1. Ensure that you did not leave tools or parts inside the system.

2. Place the cover over the sides of the chassis, and slide the cover forward.

3. Tighten the thumbscrew at the back of the system to secure the cover. See Figure 4-3.

4. Replace the system in the rack, and reconnect the peripheral cables.

5. To replace the optional bezel, hook the right end of the bezel onto the chassis, then fit the bezel onto the system. Secure the bezel with the keylock. See Figure 4-2.

6. Reconnect the system to the electrical outlet, and turn on the system.

Troubleshooting a Wet System

Problem

l Liquid spilled on the system.

l Excessive humidity.

Action

1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2. Open the system. See "Opening the System."

3. Remove all expansion cards installed in the system. See "Removing an Expansion Card" in "Installing System Components."

4. Let the system dry thoroughly for at least 24 hours.

5. Close the system. See "Closing the System."

6. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the system does not start properly, see "Getting Help."

7. If the system starts properly, shut down the system and reinstall all of the expansion cards that you removed. See "Installing an Expansion Card" in

"Installing System Components."

8. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running the System Diagnostics."

If the tests fail, see "Getting Help."

Troubleshooting a Damaged System

Problem

l System was dropped or damaged.

Action

1. Open the system. See "Opening the System."

2. Ensure that the following components are properly installed:

l Expansion cards

l Power supplies

l Fans

3. Ensure that all cables are properly connected.

4. Close the system. See "Closing the System."

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

5. Run the system board tests in the system diagnostics. See "Running the System Diagnostics."

If the tests fail, see "Getting Help."

Troubleshooting the System Battery

Problem

l System message indicates a problem with the battery.

l System Setup program loses system configuration information.

l System date and time do not remain current.

Action

1. Re-enter the time and date through the System Setup program. See "Using the System Setup Program" in your User's Guide.

2. Turn off the system and disconnect it from the electrical outlet for at least one hour.

3. Reconnect the system to the electrical outlet and turn on the system.

4. Enter the System Setup program.

If the date and time are not correct in the System Setup program, replace the battery. See "System Battery" in "Installing System Components."

If the problem is not resolved by replacing the battery, see "Getting Help."

Troubleshooting the Power Supply

Problem

l System-status indicators are amber.

Action

1. Run the appropriate online diagnostics test. See "Using Server Administrator Diagnostics" in "Running the System Diagnostics."

2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

3. Open the system. See "Opening the System."

4. Ensure that the power supply is properly installed by removing and reinstalling it. See "Power Supply" in "Installing System Components."

If the problem persists, remove the faulty power supply. See "Removing the Power Supply" in "Installing System Components."

5. Install a new power supply. See "Installing the Power Supply" in "Installing System Components."

If the problem persists, see "Getting Help."

Troubleshooting System Cooling Problems

NOTE: If the system is turned off for long periods of time (for weeks or months), the NVRAM may lose its system configuration information. This situation is caused by a defective battery.

NOTE: Some software may cause the system time to speed up or slow down. If the system seems to operate normally except for the time kept in the System Setup program, the problem may be caused by software rather than by a defective battery.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

Problem

l Systems management software issues a fan-related error message.

Action

Ensure that none of the following conditions exist:

l Ambient temperature is too high.

l External airflow is obstructed.

l Cables inside the system obstruct airflow.

l An individual cooling fan has failed. See "Troubleshooting a Fan."

Troubleshooting a Fan

Problem

l System-status indicator is amber.

l Systems management software issues a fan-related error message.

Action

1. Run the appropriate diagnostic test. See "Using Server Administrator Diagnostics" in Running System Diagnostics."

2. Open the system. See "Opening the System."

3. Ensure that the faulty fan's power cable is firmly attached to the fan power connector. See "Fan Assembly" in "Installing System Components."

4. If the problem is not resolved, install a new fan. See "Fan Assembly" in "Installing System Components."

If the replacement fan is working properly, close the system. See "Closing the System."

If the replacement fan does not operate, see "Getting Help."

Troubleshooting System Memory

Problem

l Faulty memory module.

l Faulty system board.

Action

1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

NOTE: Wait 30 seconds for the system to recognize the fan and determine whether it is working properly.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

2. Turn on the system and attached peripherals.

If an error messages does not appear, go to step 12.

3. Enter the System Setup program and check the system memory setting. See "Using the System Setup Program" in your User's Guide.

If the amount of memory installed matches the system memory setting, go to step 12.

4. Remove the bezel. See Figure 4-2.

5. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

6. Open the system. See "Opening the System."

7. Ensure that the memory banks are populated correctly. See "Memory Module Installation Guidelines" in "Installing System Components."

If the memory modules are populated correctly, continue to the next step.

8. Reseat the memory modules in their sockets. See "Installing Memory Modules" in "Installing System Components."

9. Close the system. See "Closing the System."

10. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

11. Enter the System Setup program and check the system memory setting. See "Using the System Setup Program" in your User's Guide.

If the amount of memory installed does not match the system memory setting, then perform the following steps:

a. Turn off the system and attached peripherals, and disconnect the system from its electrical outlet.

b. Open the system. See "Opening the System."

c. Swap the memory modules in bank 1 with another bank of the same capacity. See "Installing Memory Modules" in "Installing System Components."

d. Close the system. See "Closing the System."

e. Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.

f. As the system boots, observe the monitor screen and the indicators on the keyboard.

12. Perform the following steps:

a. Turn off the system and attached peripherals, and disconnect the system from its electrical outlet.

b. Open the system. See "Opening the System."

c. Repeat step c through step f in step 11 for each memory module installed.

If the problem persists, see "Getting Help."

Troubleshooting an Optical Drive

Problem

l System cannot read data from a CD or DVD.

l Optical drive indicator does not blink during boot.

Action

1. Try using a different CD or DVD that you know works properly.

2. Enter the System Setup program and ensure that the drive's IDE controller is enabled. See "Using the System Setup Program" in the User's Guide.

3. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

4. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

5. Open the system. See "Opening the System."

6. Ensure that the interface cable is securely connected to the optical drive and to the controller.

7. Ensure that a power cable is properly connected to the drive.

8. Close the system. See "Closing the System."

9. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem is not resolved, see "Getting Help."

Troubleshooting SCSI Hard Drives

Problem

l Device driver error.

l Hard drive not recognized by the system.

Action

1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running System Diagnostics."

For information about testing the controller, see the SCSI or RAID controller's documentation.

If the tests fail, continue to the next step.

2. Restart the system and enter the SCSI configuration utility.

3. Ensure that the primary SCSI channel is enabled, and restart the system.

4. Ensure that the required device drivers are installed and configured correctly.

5. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

6. Open the system. See "Opening the System."

7. Ensure that the hard-drive interface cable is properly connected between the drive and the controller card. See the documentation supplied with the controller card.

8. If the hard drive is the boot drive, ensure that the drive is configured and connected properly. See "Configuring the Boot Drive" in "Installing Drives."

9. Ensure that a power cable is properly connected to the drive.

10. Ensure that the hard drive is configured with a unique SCSI ID number and that the drive is terminated or not terminated as appropriate. See the documentation for the hard drive.

11. Close the system. See "Closing the System."

12. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem persists, continue to the next step.

13. Format and partition the hard drive. See the operating system documentation.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

NOTICE: This procedure can destroy data stored on the hard drive. Before you continue, back up all files on the hard drive.

NOTE: To enter the utility, press
or , depending on the utility. See the documentation supplied with the controller for information about the configuration utility.

14. If possible, restore the files to the drive.

If the problem persists, see "Getting Help."

Troubleshooting SATA Hard Drives

Troubleshooting a SATA Hard Drive

Problem

l Faulty hard drive

l Damaged or improperly connected hard-drive cables

Action

1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running the System Diagnostics."

2. Enter the System Setup program and verify that the system is configured correctly. See "Using the System Setup Program" in your User's Guide.

3. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

4. Open the system. See "Opening the System."

5. Ensure that the hard-drive interface cable is properly connected between the drive and the system board.

To identify system board connectors, see Figure A-3.

6. If the hard drive is the boot drive, ensure that the drive is configured and connected properly. See "Configuring the Boot Drive" in "Installing Drives."

7. Ensure that the power cable is properly connected to the drive.

8. Close the system. See "Closing the System."

9. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

10. Format and partition the hard drive. See the operating system documentation.

11. If possible, restore the files to the drive.

If the problem persists, see "Getting Help."

Troubleshooting a SATA Hard Drive in a RAID Configuration

Problem

l Device driver error

l Damaged or improperly connected hard-drive cables

Action

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

NOTICE: This troubleshooting procedure can destroy data stored on the hard drive. Before you proceed, back up all files on the hard drive.

NOTE: If the hard drive is used in a RAID configuration, see "Troubleshooting a SATA Hard Drive in a RAID Configuration."

1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running the System Diagnostics."

2. Restart your system and enter the RAID configuration utility. See the RAID controller documentation.

3. Ensure that the required device drivers are installed and are configured correctly. See the RAID controller's documentation.

4. Remove the bezel. See Figure 4-2.

5. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

6. Open the system. See "Opening the System."

7. Ensure that the hard-drive interface cable is properly connected to the drive and to the controller card. See the documentation that accompanied the controller card.

8. If the hard drive is the boot drive, ensure that the drive is configured and connected properly. See "Configuring the Boot Drive" in "Installing Drives."

9. Ensure that the power cable is properly connected to the drive.

10. Close the system. See "Closing the System."

11. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem persists, see "Getting Help."

Troubleshooting a RAID Controller Card

Problem

l Error message indicates a RAID controller problem.

l RAID controller performs incorrectly or not at all.

Action

1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running the System Diagnostics."

2. Remove the bezel. See Figure 4-2.

3. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

4. Open the system. See "Opening the System."

5. Ensure that the controller card is firmly seated in its connector. See "Installing an Expansion Card" in "Installing System Components."

6. Ensure that the appropriate cables are firmly connected to their corresponding connectors on the controller card.

7. Close the system. See "Closing the System."

8. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem persists, see the RAID controller's documentation for more information on troubleshooting.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

NOTICE: This troubleshooting procedure can destroy data stored on the hard drive. Before you proceed, back up all files on the hard drive.

NOTE: When troubleshooting a RAID controller card, also see the documentation for your operating system and the RAID controller.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

Troubleshooting Expansion Cards

Problem

l Error message indicates a problem with an expansion card.

l Expansion card performs incorrectly or not at all.

Action

1. Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" in "Running the System Diagnostics."

2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

3. Open the system. See "Opening the System."

4. Ensure that each expansion card is firmly seated in its connector. See "Installing an Expansion Card" in "Installing System Components."

5. Close the system. See "Closing the System."

6. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem persists, go to the next step.

7. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

8. Open the system. See "Opening the System."

9. Remove all expansion cards installed in the system. See "Removing an Expansion Card" in "Installing System Components."

10. Close the system. See "Closing the System."

11. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

12. Run the appropriate online diagnostic test.

If the tests fail, see "Getting Help."

13. For each expansion card you removed in step 9, perform the following steps:

a. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

b. Open the system. See "Opening the System."

c. Reinstall one of the expansion cards.

d. Close the system. See "Closing the System."

e. Run the appropriate diagnostic test.

If the tests fail, see "Getting Help."

Troubleshooting the Microprocessor

Problem

l Error message indicates a microprocessor problem.

l A heat sink is not installed for the processor.

NOTE: When troubleshooting an expansion card, see the documentation for your operating system and the expansion card.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

Action

1. Run the appropriate online diagnostics test. See "Using Server Administrator Diagnostics" in "Running the System Diagnostics."

2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

3. Open the system. See "Opening the System."

4. Ensure that the processor and heat sink are properly installed. See "Replacing the Processor" in "Installing System Components."

5. Close the system. See "Closing the System."

6. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem persists, see "Getting Help."

Back to Contents Page

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

Back to Contents Page

Installing System Components Dell PowerEdge 850 Systems Installation and Troubleshooting Guide

Cooling Shroud

System Battery

Fan Assembly

PCI Fan Module

Power Supply

Expansion Cards

Riser Card

System Memory

Processor

This section describes how to install the following system components:

l Cooling shroud

l System battery

l Fan assembly

l Power supply

l Expansion cards

l Riser card

l System memory

l Processor

Cooling Shroud

The cooling shroud covers the processor and system battery. The shroud also directs air flow to the expansion cards and system memory.

Removing the Cooling Shroud

1. Open the system. See "Opening the System" in "Troubleshooting Your System."

2. While grasping the cooling shroud, press the release latch and lift the shroud away from the fan assembly. See Figure 5-1.

3. Remove the cooling shroud.

Figure 5-1. Installing and Removing the Cooling Shroud

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

Installing the Cooling Shroud

1. Insert the tab on the side of the cooling shroud and the release latch into the fan assembly. See Figure 5-1.

2. Push the cooling shroud down until the release latch snaps into place, securing the shroud to the fan assembly.

3. Close the system. See "Closing the System" in "Troubleshooting Your System."

System Battery

Replacing the System Battery

1. Enter the System Setup program and, if possible, make a printed copy of the System Setup screens.

See "Using the System Setup Program" in the User's Guide.

2. Open the system. See "Opening the System" in "Troubleshooting Your System."

3. Remove the cooling shroud. See "Removing the Cooling Shroud."

4. Remove the riser card. See "Removing the Riser Card."

5. Locate the battery on the system board. See Figure A-3 for the battery location.

6. Grasp the battery with your fingers and pull it out of the battery socket. See Figure 5-2.

7. Push the new battery into the battery socket as shown in Figure 5-2.

Figure 5-2. Replacing the Battery

8. Reinstall the riser card. See "Installing the Riser Card."

9. Install the cooling shroud. See "Installing the Cooling Shroud."

10. Close the system. See "Closing the System" in "Troubleshooting Your System."

11. Enter the System Setup program to confirm that the battery operates properly.

12. From the main screen, select System Time to enter the correct time and date.

Also, re-enter any system configuration information that is no longer displayed on the System Setup screens, and then exit the System Setup program.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

NOTE: The side of the battery labeled "+" must face toward the open side of the battery socket.

13. To test the newly installed battery, see "Troubleshooting the System Battery" in "Troubleshooting Your System."

Fan Assembly

The fan assembly contains two fans and provides cooling for the processor and memory modules.

Removing the Fan Assembly

1. Open the system. See "Opening the System" in "Troubleshooting Your System."

2. Remove the cooling shroud. See "Removing the Cooling Shroud."

3. Disconnect the fan assembly's power cable from the system board. See Figure 5-3.

4. Disconnect the PCI fan cable from the fan assembly connector, if present.

5. Remove the data cable from hard drive 1 if installed. See Figure 5-3.

6. Pull the cables out of the fan assembly's cable tray. See Figure 5-3.

7. While pressing the two release levers on the fan assembly, lift the fan assembly off of the two securing posts and out of the chassis. See Figure 5-3.

Figure 5-3. Installing and Removing the Fan Assembly

Installing the Fan Assembly

1. Align the holes in the fan assembly with the two fan assembly securing posts. See Figure 5-3.

2. Lower the fan assembly until the release levers snap onto the securing posts.

3. Route the cables in the fan assembly cable tray. See Figure 5-3.

4. Reconnect the hard drive 1 data cable to the hard drive. See Figure 5-3.

5. Reconnect the PCI fan cable to the fan assembly connector, if applicable.

6. Reconnect the fan assembly power cable to the system board.

7. Install the cooling shroud. See "Installing the Cooling Shroud."

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

8. Close the system. See "Closing the System" in "Troubleshooting Your System."

PCI Fan Module

The PCI fan module provides cooling for the expansion cards.

Removing the PCI Fan Module

1. Open the system. See "Opening the System" in "Troubleshooting Your System."

2. Disconnect the fan module's power cable. Depending on your system, this connector may be on the fan assembly cable or the daughter card.

3. Gently pull the fan module up and away from the alignment pin on the chassis, and remove the fan module from the system. See Figure 5-4.

Figure 5-4. Installing and Removing the PCI Fan Module

Installing the PCI Fan Module

1. With the fan power cable facing towards the rear of the system, align the fan module alignment hole with the alignment pin on the chassis. See

Figure 5-4.

2. Install the PCI fan module against the tab and atop the alignment pin on the system chassis.

3. Reconnect the fan module's power cable to the connector on the fan assembly or daughter card.

4. Close the system. See "Closing the System" in "Troubleshooting Your System."

Power Supply

The system supports a single nonredundant power supply.

Removing the Power Supply

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1. Open the system. See "Opening the System" in "Troubleshooting Your System."

2. Disconnect the following power supply cables:

a. P3 from the hard drive cable harness

b. P2 from system board connector 12V

c. P1 from system board connector PWR_CONN

3. Using a #2 Phillips screwdriver, remove the screw at the front of the power supply that secures the power supply to the chassis. See Figure 5-5.

4. Slide the power supply forward and lift straight up to remove the power supply from the chassis.

Figure 5-5. Installing and Removing the Power Supply

Installing the Power Supply

1. Lower the power supply into the chassis and slide it backward until the four pins on the power supply are engaged into the securing brackets.

2. Using a #2 Phillips screwdriver, install the screw at the front of the power supply that secures the power supply to the chassis.

3. Connect the following power supply cables:

a. P3 to the hard drive cable harness

b. P2 to the system board connector 12V

c. P1 to the system board connector PWR_CONN

4. Close the system. See "Closing the System" in "Troubleshooting Your System."

Expansion Cards

The system is available with an optional PCIe riser card or PCI-X/PCIe riser card. The PCIe riser card provides one PCIe x4-lane expansion slot and one PCIe x8-lane expansion slot, and the PCI-X/PCIe riser card provides one PCI-X expansion slot and one PCIe x8-lane expansion slot. If you are installing a remote access controller card, it must be installed in the upper slot of a PCI-X/PCIe riser card. See "Riser Card Connectors" in "Jumpers, Switches, and Connectors" for the locations of the expansion-card slots on the two types of riser cards.

Installing an Expansion Card

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

1. Open the system. See "Opening the System" in "Troubleshooting Your System."

2. Remove the expansion-card retainer adjacent to the expansion card slots. See Figure 5-6.

3. Remove the filler bracket on the slot you will be using.

4. Insert the expansion card firmly into the expansion-card connector on the riser card until the card is fully seated.

5. Replace the expansion-card retainer. See Figure 5-6.

6. Connect any internal or external cable(s) to the expansion card.

7. Close the system. See "Closing the System" in "Troubleshooting Your System."

Figure 5-6. Installing and Removing Expansion Cards

Removing an Expansion Card

1. Open the system. See "Opening the System" in "Troubleshooting Your System."

2. Disconnect any internal or external cable(s) that are connected to the expansion card.

3. Lift the expansion-card retainer adjacent to the PCI slots. See Figure 5-6.

4. Grasp the expansion card and carefully pull it away from the expansion-card connector.

If you are removing a SCSI controller card, disconnect the cables from the card that connects to the SCSI hard drives.

5. If you are permanently removing the card, replace the metal filler bracket over the empty card-slot opening.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

NOTE: Keep this bracket if you need to remove the expansion card. Filler brackets must be installed over empty expansion card slots to maintain Federal Communications Commission (FCC) certification of the system. The brackets also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system.

NOTE: Ensure that the expansion-card bracket is also inserted into the securing slot on the chassis's back panel.

NOTE: You may need to remove the riser card in order to install certain expansion cards with internal connectors. See "Riser Card."

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

NOTE: Filler brackets must be installed over empty expansion-card slots to maintain FCC certification of the system. The brackets also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system.

6. Replace the expansion-card retainer.

7. Close the system. See "Closing the System" in "Troubleshooting Your System."

Riser Card

The riser card provides two expansion-card slots. See "Expansion Cards" for detailed information on the expansion-card slots.

Removing the Riser Card

1. Open the system. See "Opening the System" in "Troubleshooting Your System."

2. Remove any expansion card(s). See "Removing an Expansion Card."

3. Using a #2 Phillips screwdriver, remove the two screws that secure the riser card to the chassis. See Figure 5-7.

4. Lift the riser card straight up and remove the riser card from the system.

Figure 5-7. Installing and Removing the Riser Card

Installing the Riser Card

1. Insert the riser card firmly into the riser card connector on the system board until the riser card is fully seated.

2. Using a #2 Phillips screwdriver, install the two screws that secure the riser card to the system board.

3. Install any expansion card(s). See "Installing an Expansion Card."

4. Close the system. See "Closing the System" in "Troubleshooting Your System."

System Memory

The four memory module sockets are located on the system board adjacent to the power supply and can accommodate 256 MB to 8 GB of unbuffered ECC PC- 3200 (DDR2 533) memory. See Figure A-3 for the location of the memory module sockets.

You can upgrade the system memory by installing combinations of 256-MB, 512-MB, 1-GB, and 2-GB unbuffered memory modules. If you receive an error

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

message stating that maximum memory has been exceeded, see "Indicators, Messages, and Codes" for more information. You can purchase memory upgrade kits from Dell.

Memory Module Installation Guidelines

The memory module sockets are arranged in banks (1 and 2) on two channels (A and B). The memory module banks must be installed in identical pairs.

The memory module banks are identified as follows:

Bank 1: DIMM1_A and DIMM1_B

Bank 2: DIMM2_A and DIMM2_B

For example, if socket DIMM1_A contains a 256-MB memory module, then socket DIMM1_B must contain a 256-MB memory module.

Table 5-1 shows examples of different memory configurations, based on the following guidelines:

l If only one memory module is installed, it must be installed in the DIMM1_A socket.

l A bank must contain identical memory modules.

l Install the memory modules in bank 1 (DIMM1_x) before installing memory modules in bank 2 (DIMM2_x).

l Installing three memory modules is not supported.

Table 5-1. Sample Memory Module Configurations

Installing Memory Modules

1. Open the system. See "Opening the System" in "Troubleshooting Your System."

2. Locate the memory module sockets. See Figure A-3.

3. Press the ejectors on the memory module socket down and out, as shown in Figure 5-8, to allow the memory module to be inserted into the socket.

4. Align the memory module's edge connector with the alignment keys of the memory module socket, and insert the memory module in the socket.

5. Press down on the memory module with your thumbs while pulling up on the ejectors with your index fingers to lock the memory module into the socket.

When the memory module is properly seated in the socket, the ejectors on the memory module socket align with the ejectors on the other sockets that have memory modules installed.

NOTE: The memory modules must be PC-3200 compliant.

Total Memory

DIMM1_A

DIMM2_A

DIMM1_B

DIMM2_B

256 MB 256 MB None None None

512 MB 256 MB None 256 MB None

512 MB 512 MB None None None

1 GB 256 MB 256 MB 256 MB 256 MB

1 GB 512 MB None 512 MB None

1.5 GB 512 MB 256 MB 512 MB 256 MB

2 GB 512 MB 512 MB 512 MB 512 MB

2 GB 1 GB None 1 GB None

3 GB 1 GB 512 MB 1 GB 512 MB

4 GB 1 GB 1 GB 1 GB 1 GB

4 GB 2 GB None 2 GB None

5 GB 2 GB 512 MB 2 GB 512 MB

6 GB 2 GB 1 GB 2 GB 1 GB

8 GB 2 GB 2 GB 2 GB 2 GB

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

NOTE: The memory module socket has two alignment keys that allow you to install the memory module in the socket in only one way.

6. Repeat step 2 through step 5 of this procedure to install the remaining memory modules. See Table 5-1 for valid memory configurations.

7. Close the system. See "Closing the System" in "Troubleshooting Your System."

8. (Optional) Press to enter the System Setup program, and check the System Memory setting on the main System Setup screen.

The system should have already changed the value to reflect the newly installed memory.

9. If the value is incorrect, one or more of the memory modules may not be installed properly. Repeat step 1 through step 8 of this procedure, checking to

ensure that the memory modules are firmly seated in their sockets.

10. Run the system memory test in the system diagnostics. See "Running the System Diagnostics."

Figure 5-8. Installing and Removing a Memory Module

Removing Memory Modules

1. Open the system. See "Opening the System" in "Troubleshooting Your System."

2. Locate the memory module sockets. See Figure A-3.

3. Press down and out on the ejectors on each end of the socket until the memory module pops out of the socket. See Figure 5-8.

4. Close the system. See "Closing the System" in "Troubleshooting Your System."

Processor

You can upgrade the processor to take advantage of future options in speed and functionality. The processor and its associated internal cache memory are contained in a pin grid array (PGA) package that is installed in a ZIF socket on the system board.

Replacing the Processor

1. Open the system. See "Opening the System" in "Troubleshooting Your System."

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

NOTICE: Never remove the heat sink from a processor unless you intend to remove the processor. The heat sink is necessary to maintain proper thermal conditions.

NOTE: When you remove the heat sink, the possibility exists that the processor might adhere to the heat sink and be removed from the socket. It is recommended that you remove the heat sink while the processor is still warm.

2. Remove the cooling shroud. See "Removing the Cooling Shroud."

3. Using a #2 Phillips screwdriver, loosen the four captive screws that secure the heat sink to the system board. See Figure 5-9.

Figure 5-9. Installing and Removing the Heat Sink

4. Wait 30 seconds for the heat sink to loosen from the processor.

5. If the heat sink has not separated from the processor, carefully rotate the heat sink in a clockwise, then counterclockwise, direction until it releases from the processor. Do not pry the heat sink off of the processor.

6. Lift the heat sink off of the processor and set the heat sink upside down so as not to contaminate the thermal grease.

7. Press down on the processor socket release lever, then pull the release lever upward to the fully open position. See Figure 5-10.

8. Open the processor cover. See Figure 5-10.

9. Lift the processor vertically out of the socket. Leave the processor cover and release lever in the open position so that the socket is ready for the new processor. See Figure 5-10.

Figure 5-10. Installing and Removing the Processor

10. Unpack the new processor and heat sink.

11. Ensure that the processor socket release lever is in the fully open position.

12. Align the pin 1 corners of the processor and socket. See Figure 5-10.

13. Set the processor lightly in the socket and ensure that the processor is level in the socket. When the processor is positioned correctly, press it gently to

seat it in the socket.

14. Close the processor cover.

NOTICE: You must position the processor correctly in the socket to avoid damaging the processor and the system board when you turn on the system. Be careful not to touch or bend the pins on the socket.

15. Rotate the release lever back down until it snaps into place, securing the processor cover.

16. Install the heat sink.

a. Using a clean lint-free cloth, remove the existing thermal grease from the heat sink.

b. Apply thermal grease evenly to the top of the processor.

c. Place the heat sink onto the processor. See Figure 5-9.

d. Using a #2 Phillips screwdriver, tighten in a diagonal pattern the four captive screws that secure the heat sink to the system board. See Figure 5- 9.

17. Install the cooling shroud. See "Installing the Cooling Shroud."

18. Close the system. See "Closing the System" in "Troubleshooting Your System."

As the system boots, it detects the presence of the new processor and automatically changes the system configuration information in the System Setup program.

19. Press to enter the System Setup program, and check that the processor information matches the new system configuration.

See your User's Guide for instructions about using the System Setup program.

20. Run the system diagnostics to verify that the new processor operates correctly.

See "Running the System Diagnostics" for information about running the diagnostics and troubleshooting processor problems.

Back to Contents Page

NOTE: Use the heat sink that you removed earlier in this procedure.

Back to Contents Page

Installing Drives Dell PowerEdge 850 Systems Installation and Troubleshooting Guide

Optical Drive

SCSI Configuration Information

Configuring the Boot Drive

Hard Drives

Installing a SCSI Controller Card

Your system contains up to two SATA or SCSI hard drives and an optional optical drive. If your system contains SCSI hard drives, they must be connected to a optional SCSI controller card. The integrated SATA controller supports up to two SATA hard drives.

Optical Drive

The optional optical drive is mounted in a bracket using two alignment pins and a spring clip on top of hard drive 0. An interposer card is connected to the back of the drive which allows the drive to be connected to the Pri-IDE connector on the system board.

Removing the Optical Drive

1. Open the system. See "Opening the System" in "Troubleshooting Your System."

2. Disconnect the power and interface cables from the optical drive's interposer card.

3. Pull the two captive fasteners that secure the interposer card to the hard drive 0 carrier. See Figure 6-1.

4. Disconnect the interposer card from the optical drive.

5. Press the bracket release lever that secures the optical drive to the hard drive 0 carrier. See Figure 6-1.

6. Lift and tilt the optical drive up and out of the bracket as shown in Figure 6-1.

Figure 6-1. Removing and Installing the Optional Optical Drive

Installing the Optical Drive

1. Align the optical drive's mounting holes with the retaining pins on the hard drive 0 bracket. See Figure 6-1.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

2. Rotate the drive downward until it snaps into place.

3. Connect the interposer card to the optical drive.

Push the plungers into the captive fastener barrels until they snap into place.

4. Connect the interface and power cables to the optical drive's interposer card.

5. Close the system. See "Closing the System" in "Troubleshooting Your System."

SCSI Configuration Information

Although SCSI drives are installed in essentially the same way as other drives, their configuration requirements are different. To install and configure a SCSI drive, follow the guidelines in the following subsections.

SCSI Interface Cables

SCSI interface connectors are keyed for correct insertion. Keying ensures that the pin-1 wire in the cable connects to pin 1 in the connectors on both ends. When you disconnect an interface cable, take care to grasp the cable connector, rather than the cable itself, to avoid stress on the cable.

SCSI ID Numbers

Each drive attached to a SCSI controller must have a unique SCSI ID number from 0 to 15.

l The SCSI hard drive from which the system boots is configured as SCSI ID 0.

l If you install optional SCSI drives or change your SCSI configuration, see the documentation for each SCSI drive for information on setting the appropriate SCSI ID number.

Device Termination

SCSI logic requires that termination be enabled for the two drives at opposite ends of the SCSI chain and disabled for all drives in between. For internal SCSI drives, termination is configured automatically. See the documentation provided with any optional SCSI drive you purchase for information on disabling termination.

Configuring the Boot Drive

The drive or device from which the system boots is determined by the boot order specified in the System Setup program. See "Using the System Setup Program" in your User's Guide. To boot the system from a hard drive or drive array, the drive(s) must be connected to the appropriate controller:

l To boot from a single SATA hard drive, the master drive (drive 0) must be connected to the SATA_PORT_0 connector on the daughter card. To identify daughter card connectors, see Figure A-3.

l To boot from a single SCSI hard drive, the drive must be connected to the SCSI controller card. See the documentation that accompanied the controller card.

l To boot from a SCSI RAID array, the drive must be connected to the RAID controller card. See the documentation that accompanied the controller card.

Hard Drives

Your system contains up to two non-hot-pluggable SATA or SCSI hard drives. If your system contains SCSI hard drives, they must be connected to a SCSI controller card. The cables for hard drive 1 are routed through a cable clamp mounted to the chassis.

Removing a Hard Drive

The procedures for removing and installing SATA or SCSI hard drives are the same.

1. Open the system. See "Opening the System" in "Troubleshooting Your System."

NOTE: There is no requirement that SCSI ID numbers be assigned sequentially or that drives be attached to the cable in order by ID number.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

2. If applicable, remove the optical drive.

Remove the optical drive if you are removing hard drive 0. See "Removing the Optical Drive."

3. Disconnect the power and interface cables from the hard drive.

The interface cables for SATA hard drives are connected to the daughter card. See Figure A-3 for the location of the daughter card connectors.

The interface cables for SCSI hard drives are connected to a controller card.

4. Loosen the captive screw that secures the hard-drive carrier to the chassis. See Figure 6-2.

5. Slide the hard-drive carrier backward and lift the carrier out of the chassis.

Figure 6-2. Removing the Hard-Drive Carrier

6. Using a #2 Phillips screwdriver, remove the four screws that secure the hard drive to the carrier and remove the drive from the carrier. See Figure 6-3.

Figure 6-3. Removing the Hard Drives From the Drive Carriers

Installing a Hard Drive

1. Align the hard-drive mounting holes with the holes in the drive carrier.

2. Using a #2 Phillips screwdriver, install the four screws that secure the hard drive to the carrier. See Figure 6-3.

3. Align the hard-drive carrier so that the tabs on the chassis slide into the notches in the carrier. See Figure 6-2.

4. Slide the carrier forward until it stops.

5. Tighten the captive screw that secures the hard-drive carrier to the chassis.

6. Connect the power and interface cables to the new drive.

The interface cables for SATA hard drives are connected to the daughter card. See Figure A-3 for the location of the daughter card connectors.

The interface cables for SCSI hard drives are connected to a SCSI controller card.

7. Install the CD drive.

Install the CD drive if you are removing hard drive 0. See "Installing the Optical Drive."

8. Close the system. See "Closing the System" in "Troubleshooting Your System."

Installing a SCSI Controller Card

See "Installing an Expansion Card" in "Installing System Components" for general instructions about installing the controller card. See the controller card documentation for specific information on installing and configuring the card.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

Back to Contents Page

Back to Contents Page

Service-Only Parts Replacement Procedures Dell PowerEdge 850 Systems Installation and Troubleshooting Guide

Recommended Tools

Control Panel Assembly

Daughter Card

System Board

Recommended Tools

You may need the following items to perform the procedures in this section:

l Key to the system keylock

l Wrist grounding strap

l #2 Phillips screwdriver

Control Panel Assembly

Removing the Control Panel Assembly

1. Open the system. See "Opening the System" in "Troubleshooting Your System."

2. Disconnect the control panel cables. See Figure 7-1.

3. Using a #2 Phillips screwdriver, remove the two screws that secure the control panel assembly to the chassis. See Figure 7-1.

4. Carefully lift the back of the control panel assembly to clear the chassis mounting studs, and remove the assembly from the system.

Figure 7-1. Removing the Control Panel Assembly

Installing the Control Panel Assembly

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

1. Align the control panel assembly's mounting holes with the chassis mounting holes. See Figure 7-1.

2. Using a #2 Phillips screwdriver, install the two screws that secure the control panel assembly to the chassis. See Figure 7-1.

3. Connect the control panel cables. See Figure 7-1.

4. Close the system. See "Closing the System" in "Troubleshooting Your System."

Daughter Card

Removing the Daughter Card

1. Open the system. See "Opening the System" in "Troubleshooting Your System."

2. Disconnect the SATA, control panel, and optical drive cables, and disconnect the PCI fan cable if present. See Figure 7-2.

3. Using a #2 Phillips screwdriver, remove the screw that secures the daughter card to the chassis. See Figure 7-2.

4. Slide the daughter card away from the connector on the edge of the system board and remove it from the system.

Figure 7-2. Removing the Daughter Card

Installing the Daughter Card

1. Slide the daughter card into the connector on the edge of the system board. See Figure 7-2.

2. Using a #2 Phillips screwdriver, install the screw that secures the daughter card to the chassis. See Figure 7-2.

3. Connect the optical drive, control panel, and SATA cables, and connect the PCI fan cable if applicable. See Figure 7-2.

4. Close the system. See "Closing the System" in "Troubleshooting Your System."

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

System Board

The system board provides interface signal routing between the system board and the two SATA hard-drive bays, the optional CD drive, and the control panel. In addition, the power supply is connected to the system board using two cables.

The system board and system board tray are removed and replaced as a single assembly.

Removing the System Board Assembly

1. Open the system. See "Opening the System" in "Troubleshooting Your System."

2. Remove the cooling shroud. See "Removing the Cooling Shroud" in "Installing System Components."

3. Remove the heat sink and processor. See "Replacing the Processor" in "Installing System Components."

4. Remove the memory modules. See "Removing Memory Modules" in "Installing System Components."

5. Remove the fan module. See "Removing the Fan Assembly" in "Installing System Components."

6. If applicable, disconnect the optical drive interface cable from the daughter card connector PRI_IDE1. See Figure A-3.

7. Disconnect the two control-panel interface cables from the FRONT_PANEL connector on the system board and the USB_CONN connector on the daughter card. See Figure A-3.

8. Disconnect the hard-drive interface cables:

a. If SCSI hard drives are installed, disconnect the interface cable from the controller card.

b. If SATA hard drives are installed, disconnect the interface cable from the SATA_0 and SATA_1 connectors on the daughter card. See Figure A-3.

9. Remove all PCI expansion cards installed on the riser card. See "Removing an Expansion Card" in "Installing System Components."

10. Remove the riser card. See "Removing the Riser Card" in "Installing System Components."

11. Disconnect the chassis intrusion cable from the INTRUSION_SWITCH connector on the system board.

12. Disconnect the two power cables from the 12V and PWR_CONN connectors on the system board. See Figure A-3.

13. Loosen the captive screw that secures the system board tray to the chassis floor. See Figure 7-3.

14. Using the tab on the system board tray, slide the system board forward (toward the front of the system) and lift the assembly up and out of the chassis. See Figure 7-3.

15. Lay the system board tray down on a smooth, nonconductive work surface.

Figure 7-3. Removing the System Board Assembly

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

NOTE: As you remove the memory modules, record the memory module socket locations to ensure proper installation.

Installing the System Board Assembly

1. Unpack the new system board assembly.

2. Align the system board tray so that the tabs on the chassis floor slide into the notches in the system board tray.

3. Slide the system board tray backward until it stops.

4. Using a #2 Phillips screwdriver, tighten the screw that secures the system board tray to the chassis. See Figure 7-3.

5. Install the fan module. See "Installing the Fan Assembly" in "Installing System Components."

6. Connect the two power cables to the 12V and PWR_CONN connectors on the system board. See Figure A-3.

7. Connect the chassis intrusion cable to the INTRUSION_SWITCH connector on the system board.

8. Install the riser card. See "Installing the Riser Card" in "Installing System Components."

9. Using a #2 Phillips screwdriver, tighten the two screws that secure the riser card to the system board.

10. Install any PCI expansion cards that you removed. See "Installing an Expansion Card" in "Installing System Components."

11. Connect the hard-drive interface cables:

a. If SCSI hard drives are installed, connect the interface cable to the PCI controller card.

b. If SATA hard drives are installed, connect the interface cable to the SATA_0 and SATA_1 connectors on the daughter card. See Figure A-3.

12. Install the processor and heat sink. See "Replacing the Processor" in "Installing System Components."

13. Install the memory modules. See "Installing Memory Modules" in "Installing System Components."

14. Connect the two control-panel interface cables to the FRONT_PANEL connector on the system board and the USB_CONN connector on the daughter

card. See Figure A-3.

15. If applicable, connect the optical drive interface cable to the PRI_IDE1 connector on the daughter card. See Figure A-3.

16. Install the cooling shroud. See "Replacing the Processor" in "Installing System Components."

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

NOTE: Install the memory modules as noted in step 4 of the procedure in "Removing the System Board Assembly."

17. Close the system. See "Closing the System" in "Troubleshooting Your System."

Back to Contents Page

Back to Contents Page

Getting Help Dell PowerEdge 850 Systems Installation and Troubleshooting Guide

Technical Assistance

Dell Enterprise Training and Certification

Problems With Your Order

Product Information

Returning Items for Warranty Repair or Credit

Before You Call

Contacting Dell

Technical Assistance

If you need assistance with a technical problem, perform the following steps:

1. Complete the procedures in "Troubleshooting Your System."

2. Run the system diagnostics and record any information provided.

3. Make a copy of the Diagnostics Checklist, and fill it out.

4. Use Dell's extensive suite of online services available at Dell Support at support.dell.com for help with installation and troubleshooting procedures.

For more information, see "Online Services."

5. If the preceding steps have not resolved the problem, call Dell for technical assistance.

NOTE: Call technical support from a phone near or at the system so that technical support can assist you with any necessary procedures.

NOTE: Dell's Express Service Code system may not be available in all countries.

When prompted by Dell's automated telephone system, enter your Express Service Code to route the call directly to the proper support personnel. If you do not have an Express Service Code, open the Dell Accessories folder, double-click the Express Service Code icon, and follow the directions.

For instructions on using the technical support service, see "Technical Support Service" and "Before You Call."

NOTE: Some of the following services are not always available in all locations outside the continental U.S. Call your local Dell representative for information on availability.

Online Services

You can access Dell Support at support.dell.com. Select your region on the WELCOME TO DELL SUPPORT page, and fill in the requested details to access help tools and information.

You can contact Dell electronically using the following addresses:

l World Wide Web

www.dell.com/

www.dell.com/ap/ (Asian/Pacific countries only)

www.dell.com/jp (Japan only)

www.euro.dell.com (Europe only)

www.dell.com/la (Latin American countries)

www.dell.ca (Canada only)

l Anonymous file transfer protocol (FTP)

ftp.dell.com/

Log in as user:anonymous, and use your e-mail address as your password.

l Electronic Support Service

support@us.dell.com

apsupport@dell.com (Asian/Pacific countries only)

support.jp.dell.com (Japan only)

support.euro.dell.com (Europe only)

l Electronic Quote Service

sales@dell.com

apmarketing@dell.com (Asian/Pacific countries only)

sales_canada@dell.com (Canada only)

l Electronic Information Service

info@dell.com

AutoTech Service

Dell's automated technical support serviceAutoTechprovides recorded answers to the questions most frequently asked by Dell customers about their portable and desktop computer systems.

When you call AutoTech, use your touch-tone telephone to select the subjects that correspond to your questions.

The AutoTech service is available 24 hours a day, 7 days a week. You can also access this service through the technical support service. See the contact information for your region.

Automated Order-Status Service

To check on the status of any Dell products that you have ordered, you can go to support.dell.com, or you can call the automated order-status service. A recording prompts you for the information needed to locate and report on your order. See the contact information for your region.

Technical Support Service

Dell's technical support service is available 24 hours a day, 7 days a week, to answer your questions about Dell hardware. Our technical support staff use computer-based diagnostics to provide fast, accurate answers.

To contact Dell's technical support service, see "Before You Call" and then see the contact information for your region.

Dell Enterprise Training and Certification

Dell Enterprise Training and Certification is available; see www.dell.com/training for more information. This service may not be offered in all locations.

Problems With Your Order

If you have a problem with your order, such as missing parts, wrong parts, or incorrect billing, contact Dell for customer assistance. Have your invoice or packing slip available when you call. See the contact information for your region.

Product Information

If you need information about additional products available from Dell, or if you would like to place an order, visit the Dell website at www.dell.com. For the telephone number to call to speak to a sales specialist, see the contact information for your region.

Returning Items for Warranty Repair or Credit

Prepare all items being returned, whether for repair or credit, as follows:

1. Call Dell to obtain a Return Material Authorization Number, and write it clearly and prominently on the outside of the box.

For the telephone number to call, see the contact information for your region.

2. Include a copy of the invoice and a letter describing the reason for the return.

3. Include a copy of any diagnostic information (including the Diagnostics Checklist) indicating the tests you have run and any error messages reported by

the system diagnostics.

4. Include any accessories that belong with the item(s) being returned (such as power cables, media such as CDs and diskettes, and guides) if the return is for credit.

5. Pack the equipment to be returned in the original (or equivalent) packing materials.

You are responsible for paying shipping expenses. You are also responsible for insuring any product returned, and you assume the risk of loss during shipment to Dell. Collect-on-delivery (C.O.D.) packages are not accepted.

Returns that are missing any of the preceding requirements will be refused at our receiving dock and returned to you.

Before You Call

NOTE: Have your Express Service Code ready when you call. The code helps Dell's automated-support telephone system direct your call more efficiently.

Remember to fill out the Diagnostics Checklist. If possible, turn on your system before you call Dell for technical assistance and call from a telephone at or near the computer. You may be asked to type some commands at the keyboard, relay detailed information during operations, or try other troubleshooting steps possible only at the computer system itself. Ensure that the system documentation is available.

Contacting Dell

To contact Dell electronically, you can access the following websites:

l www.dell.com

l support.dell.com (technical support)

l premiersupport.dell.com (technical support for educational, government, healthcare, and medium/large business customers, including Premier, Platinum, and Gold customers)

For specific web addresses for your country, find the appropriate country section in the table below.

NOTE: In certain countries, technical support specific to Dell Inspiron XPS computers is available at a separate telephone number listed for participating countries. If you do not see a telephone number listed that is specific for Inspiron XPS computers, you may contact Dell through the technical support number listed and your call will be routed appropriately.

When you need to contact Dell, use the electronic addresses, telephone numbers, and codes provided in the following table. If you need assistance in

CAUTION: Before servicing any components inside your computer, see your Product Information Guide for important safety information.

Diagnostics Checklist

Name:

Date:

Address:

Phone number:

Service Tag (bar code on the back of the computer):

Express Service Code:

Return Material Authorization Number (if provided by Dell support technician):

Operating system and version:

Peripherals:

Expansion cards:

Are you connected to a network? Yes No

Network, version, and network card:

Programs and versions:

See your operating system documentation to determine the contents of the system's start-up files. If possible, print each file. Otherwise, record the contents of each file before calling Dell.

Error message, beep code, or diagnostic code:

Description of problem and troubleshooting procedures you performed:

NOTE: Toll-free numbers are for use within the country for which they are listed.

determining which codes to use, contact a local or an international operator.

Country (City) International Access Code Country Code City Code

Department Name or Service Area, Website and E-Mail Address

Area Codes, Local Numbers, and Toll-Free Numbers

Anguilla General Support toll-free: 800-335-0031

Antigua and Barbuda General Support 1-800-805-5924

Argentina (Buenos Aires)

International Access Code: 00

Country Code: 54

City Code: 11

Website: www.dell.com.ar

E-mail: us_latin_services@dell.com

E-mail for desktop and portable computers: la-techsupport@dell.com

E-mail for servers and EMC storage products: la_enterprise@dell.com

Customer Care toll-free: 0-800-444-0730

Tech Support toll-free: 0-800-444-0733

Tech Support Services toll-free: 0-800-444-0724

Sales 0-810-444-3355

Aruba General Support toll-free: 800-1578

Australia (Sydney)

International Access Code: 0011

Country Code: 61

City Code: 2

E-mail (Australia): au_tech_support@dell.com

E-mail (New Zealand): nz_tech_support@dell.com

Home and Small Business 1-300-655-533

Government and Business toll-free: 1-800-633-559

Preferred Accounts Division (PAD) toll-free: 1-800-060-889

Customer Care toll-free: 1-800-819-339

Technical Support (portables and desktops) toll-free: 1-300-655-533

Technical Support (servers and workstations) toll-free: 1-800-733-314

Corporate Sales toll-free: 1-800-808-385

Transaction Sales toll-free: 1-800-808-312

Fax toll-free: 1-800-818-341

Austria (Vienna)

International Access Code: 900

Country Code: 43

City Code: 1

Website: support.euro.dell.com

E-mail: tech_support_central_europe@dell.com

Home/Small Business Sales 0820 240 530 00

Home/Small Business Fax 0820 240 530 49

Home/Small Business Customer Care 0820 240 530 14

Preferred Accounts/Corporate Customer Care 0820 240 530 16

Home/Small Business Technical Support 0820 240 530 14

Preferred Accounts/Corporate Technical Support 0660 8779

Switchboard 0820 240 530 00

Bahamas General Support toll-free: 1-866-278-6818

Barbados General Support 1-800-534-3066

Belgium (Brussels)

International Access Code: 00

Country Code: 32

City Code: 2

Website: support.euro.dell.com

E-mail for French-speaking Customers: support.euro.dell.com/be/fr/emaildell/

Technical Support for Inspiron XPS computers only 02 481 92 96

Technical Support for all other Dell computers 02 481 92 88

Technical Support Fax 02 481 92 95

Customer Care 02 713 15 .65

Corporate Sales 02 481 91 00

Fax 02 481 92 99

Switchboard 02 481 91 00

Bermuda General Support 1-800-342-0671

Bolivia General Support toll-free: 800-10-0238

Brazil

International Access Code: 00

Country Code: 55

City Code: 51

Website: www.dell.com/br

Customer Support, Technical Support 0800 90 3355

Technical Support Fax 51 481 5470

Customer Care Fax 51 481 5480

Sales 0800 90 3390

British Virgin Islands General Support toll-free: 1-866-278-6820

Brunei Customer Technical Support (Penang, Malaysia) 604 633 4966

Country Code: 673

Customer Service (Penang, Malaysia) 604 633 4949

Transaction Sales (Penang, Malaysia) 604 633 4955

Canada (North York, Ontario)

International Access Code: 011

Online Order Status: www.dell.ca/ostatus

AutoTech (automated technical support) toll-free: 1-800-247-9362

Customer Care (Home Sales/Small Business) toll-free: 1-800-847-4096

Customer Care (med./large business, government) toll-free: 1-800-326-9463

Technical Support (Home Sales/Small Business) toll-free: 1-800-847-4096

Technical Support (med./large bus., government) toll-free: 1-800-387-5757

Technical Support (printers, projectors, televisions, handhelds, digital jukebox, and wireless)

1-877-335-5767

Sales (Home Sales/Small Business) toll-free: 1-800-387-5752

Sales (med./large bus., government) toll-free: 1-800-387-5755

Spare Parts Sales & Extended Service Sales 1 866 440 3355

Cayman Islands General Support 1-800-805-7541

Chile (Santiago)

Country Code: 56

City Code: 2

Sales, Customer Support, and Technical Support toll-free: 1230-020-4823

China (Xiamen)

Country Code: 86

City Code: 592

Technical Support website: support.dell.com.cn

Technical Support E-mail: cn_support@dell.com

Customer Care E-mail: customer_cn@dell.com

Technical Support Fax 592 818 1350

Technical Support (Dell Dimension and Inspiron) toll-free: 800 858 2969

Technical Support (OptiPlex, Latitude, and Dell Precision) toll-free: 800 858 0950

Technical Support (servers and storage) toll-free: 800 858 0960

Technical Support (projectors, PDAs, switches, routers, and so on)

toll-free: 800 858 2920

Technical Support (printers) toll-free: 800 858 2311

Customer Care toll-free: 800 858 2060

Customer Care Fax 592 818 1308

Home and Small Business toll-free: 800 858 2222

Preferred Accounts Division toll-free: 800 858 2557

Large Corporate Accounts GCP toll-free: 800 858 2055

Large Corporate Accounts Key Accounts toll-free: 800 858 2628

Large Corporate Accounts North toll-free: 800 858 2999

Large Corporate Accounts North Government and Education toll-free: 800 858 2955

Large Corporate Accounts East toll-free: 800 858 2020

Large Corporate Accounts East Government and Education toll-free: 800 858 2669

Large Corporate Accounts Queue Team toll-free: 800 858 2572

Large Corporate Accounts South toll-free: 800 858 2355

Large Corporate Accounts West toll-free: 800 858 2811

Large Corporate Accounts Spare Parts toll-free: 800 858 2621

Colombia General Support 980-9-15-3978

Costa Rica General Support 0800-012-0435

Czech Republic (Prague)

International Access Code: 00

Country Code: 420

Website: support.euro.dell.com

E-mail: czech_dell@dell.com

Technical Support 22537 2727

Customer Care 22537 2707

Fax 22537 2714

Tech Fax 22537 2728

Switchboard 22537 2711

Denmark (Copenhagen)

International Access Code: 00

Country Code: 45

Website: support.euro.dell.com

E-mail: support.euro.dell.com/dk/da/emaildell/

Technical Support for Inspiron XPS computers only 7010 0074

Technical Support for all other Dell computers 7023 0182

Customer Care (Relational) 7023 0184

Home/Small Business Customer Care 3287 5505

Switchboard (Relational) 3287 1200

Switchboard Fax (Relational) 3287 1201

Switchboard (Home/Small Business) 3287 5000

Switchboard Fax (Home/Small Business) 3287 5001

Dominica General Support toll-free: 1-866-278-6821

Dominican Republic General Support 1-800-148-0530

Ecuador General Support toll-free: 999-119

El Salvador General Support 01-899-753-0777

Finland (Helsinki)

International Access Code: 990

Country Code: 358

City Code: 9

Website: support.euro.dell.com

E-mail: support.euro.dell.com/fi/fi/emaildell/

Technical Support 09 253 313 60

Customer Care 09 253 313 38

Fax 09 253 313 99

Switchboard 09 253 313 00

France (Paris) (Montpellier)

International Access Code: 00

Country Code: 33

City Codes: (1) (4)

Website: support.euro.dell.com

E-mail: support.euro.dell.com/fr/fr/emaildell/

Home and Small Business

Technical Support for Inspiron XPS computers only 0825 387 129

Technical Support for all other Dell computers 0825 387 270

Customer Care 0825 823 833

Switchboard 0825 004 700

Switchboard (calls from outside of France) 04 99 75 40 00

Sales 0825 004 700

Fax 0825 004 701

Fax (calls from outside of France) 04 99 75 40 01

Corporate

Technical Support 0825 004 719

Customer Care 0825 338 339

Switchboard 01 55 94 71 00

Sales 01 55 94 71 00

Fax 01 55 94 71 01

Germany (Langen)

International Access Code: 00

Country Code: 49

City Code: 6103

Website: support.euro.dell.com

E-mail: tech_support_central_europe@dell.com

Technical Support for Inspiron XPS computers only 06103 766-7222

Technical Support for all other Dell computers 06103 766-7200

Home/Small Business Customer Care 0180-5-224400

Global Segment Customer Care 06103 766-9570

Preferred Accounts Customer Care 06103 766-9420

Large Accounts Customer Care 06103 766-9560

Public Accounts Customer Care 06103 766-9555

Switchboard 06103 766-7000

Greece

International Access Code: 00

Country Code: 30

Website: support.euro.dell.com

E-mail: support.euro.dell.com/gr/en/emaildell/

Technical Support 00800-44 14 95 18

Gold Service Technical Support 00800-44 14 00 83

Switchboard 2108129810

Gold Service Switchboard 2108129811

Sales 2108129800

Fax 2108129812

Grenada General Support toll-free: 1-866-540-3355

Guatemala General Support 1-800-999-0136

Guyana General Support toll-free: 1-877-270-4609

Hong Kong

International Access Code: 001

Country Code: 852

Website: support.ap.dell.com

Technical Support E-mail: apsupport@dell.com

Technical Support (Dimension and Inspiron) 2969 3188

Technical Support (OptiPlex, Latitude, and Dell Precision) 2969 3191

Technical Support (PowerApp, PowerEdge, PowerConnect, and PowerVault) 2969 3196

Customer Care 3416 0910

Large Corporate Accounts 3416 0907

Global Customer Programs 3416 0908

Medium Business Division 3416 0912

Home and Small Business Division 2969 3105

India

Technical Support 1600 33 8045

Sales (Large Corporate Accounts) 1600 33 8044

Sales (Home and Small Business) 1600 33 8046

Ireland (Cherrywood)

International Access Code: 16

Country Code: 353

City Code: 1

Website: support.euro.dell.com

E-mail: dell_direct_support@dell.com

Technical Support for Inspiron XPS computers only 1850 200 722

Technical Support for all other Dell computers 1850 543 543

U.K. Technical Support (dial within U.K. only) 0870 908 0800

Home User Customer Care 01 204 4014

Small Business Customer Care 01 204 4014

U.K. Customer Care (dial within U.K. only) 0870 906 0010

Corporate Customer Care 1850 200 982

Corporate Customer Care (dial within U.K. only) 0870 907 4499

Ireland Sales 01 204 4444

U.K. Sales (dial within U.K. only) 0870 907 4000

Fax/Sales Fax 01 204 0103

Switchboard 01 204 4444

Italy (Milan)

International Access Code: 00

Country Code: 39

City Code: 02

Website: support.euro.dell.com

E-mail: support.euro.dell.com/it/it/emaildell/

Home and Small Business

Technical Support 02 577 826 90

Customer Care 02 696 821 14

Fax 02 696 821 13

Switchboard 02 696 821 12

Corporate

Technical Support 02 577 826 90

Customer Care 02 577 825 55

Fax 02 575 035 30

Switchboard 02 577 821

Jamaica General Support (dial from within Jamaica only) 1-800-682-3639

Japan (Kawasaki)

International Access Code: 001

Country Code: 81

City Code: 44

Website: support.jp.dell.com

Technical Support (servers) toll-free: 0120-198-498

Technical Support outside of Japan (servers) 81-44-556-4162

Technical Support (Dimension and Inspiron) toll-free: 0120-198-226

Technical Support outside of Japan (Dimension and Inspiron) 81-44-520-1435

Technical Support (Dell Precision, OptiPlex, and Latitude) toll-free:0120-198-433

Technical Support outside of Japan (Dell Precision, OptiPlex, and Latitude) 81-44-556-3894

Technical Support (PDAs, projectors, printers, routers) toll-free: 0120-981-690

Technical Support outside of Japan (PDAs, projectors, printers, routers) 81-44-556-3468

Faxbox Service 044-556-3490

24-Hour Automated Order Service 044-556-3801

Customer Care 044-556-4240

Business Sales Division (up to 400 employees) 044-556-1465

Preferred Accounts Division Sales (over 400 employees) 044-556-3433

Large Corporate Accounts Sales (over 3500 employees) 044-556-3430

Public Sales (government agencies, educational institutions, and medical institutions)

044-556-1469

Global Segment Japan 044-556-3469

Individual User 044-556-1760

Switchboard 044-556-4300

Korea (Seoul)

International Access Code: 001

Country Code: 82

City Code: 2

Technical Support toll-free: 080-200-3800

Sales toll-free: 080-200-3600

Customer Service (Penang, Malaysia) 604 633 4949

Fax 2194-6202

Switchboard 2194-6000

Technical Support (Electronics and Accessories) toll-free: 080-200-3801

Customer Technical Support (Austin, Texas, U.S.A.) 512 728-4093

Latin America

Customer Service (Austin, Texas, U.S.A.) 512 728-3619

Fax (Technical Support and Customer Service) (Austin, Texas, U.S.A.) 512 728-3883

Sales (Austin, Texas, U.S.A.) 512 728-4397

SalesFax (Austin, Texas, U.S.A.)

512 728-4600

or 512 728-3772

Luxembourg

International Access Code: 00

Country Code: 352

Website: support.euro.dell.com

E-mail: tech_be@dell.com

Technical Support (Brussels, Belgium) 3420808075

Home/Small Business Sales (Brussels, Belgium) toll-free: 080016884

Corporate Sales (Brussels, Belgium) 02 481 91 00

Customer Care (Brussels, Belgium) 02 481 91 19

Fax (Brussels, Belgium) 02 481 92 99

Switchboard (Brussels, Belgium) 02 481 91 00

Macao

Country Code: 853

Technical Support toll-free: 0800 105

Customer Service (Xiamen, China) 34 160 910

Transaction Sales (Xiamen, China) 29 693 115

Malaysia (Penang)

International Access Code: 00

Country Code: 60

City Code: 4

Website: support.ap.dell.com

Technical Support (Dell Precision, OptiPlex, and Latitude) toll-free: 1 800 88 0193

Technical Support (Dimension, Inspiron, and Electronics and Accessories) toll-free: 1 800 88 1306

Technical Support (PowerApp, PowerEdge, PowerConnect, and PowerVault) toll-free: 1800 88 1386

Customer Service (Penang, Malaysia) 04 633 4949

Transaction Sales toll-free: 1 800 888 202

Corporate Sales toll-free: 1 800 888 213

Mexico

International Access Code: 00

Country Code: 52

Customer Technical Support

001-877-384-8979

or 001-877-269-3383

Sales

50-81-8800

or 01-800-888-3355

Customer Service

001-877-384-8979

or 001-877-269-3383

Main

50-81-8800

or 01-800-888-3355

Montserrat General Support toll-free: 1-866-278-6822

Netherlands Antilles General Support 001-800-882-1519

Netherlands (Amsterdam)

International Access Code: 00

Country Code: 31

City Code: 20

Website: support.euro.dell.com

Technical Support for Inspiron XPS computers only 020 674 45 94

Technical Support for all other Dell computers 020 674 45 00

Technical Support Fax 020 674 47 66

Home/Small Business Customer Care 020 674 42 00

Relational Customer Care 020 674 4325

Home/Small Business Sales 020 674 55 00

Relational Sales 020 674 50 00

Home/Small Business Sales Fax 020 674 47 75

Relational Sales Fax 020 674 47 50

Switchboard 020 674 50 00

Switchboard Fax 020 674 47 50

New Zealand

International Access Code: 00

Country Code: 64

E-mail (New Zealand): nz_tech_support@dell.com

E-mail (Australia): au_tech_support@dell.com

Technical Support (for desktop and portable computers) toll-free: 0800 446 255

Technical Support (for servers and workstations) toll-free: 0800 443 563

Home and Small Business 0800 446 255

Government and Business 0800 444 617

Sales 0800 441 567

Fax 0800 441 566

Nicaragua General Support 001-800-220-1006

Norway (Lysaker)

Website: support.euro.dell.com

E-mail: support.euro.dell.com/no/no/emaildell/

Technical Support 671 16882

International Access Code: 00

Country Code: 47

Relational Customer Care 671 17575

Home/Small Business Customer Care 23162298

Switchboard 671 16800

Fax Switchboard 671 16865

Panama General Support 001-800-507-0962

Peru General Support 0800-50-669

Poland (Warsaw)

International Access Code: 011

Country Code: 48

City Code: 22

Website: support.euro.dell.com

E-mail: pl_support_tech@dell.com

Customer Service Phone 57 95 700

Customer Care 57 95 999

Sales 57 95 999

Customer Service Fax 57 95 806

Reception Desk Fax 57 95 998

Switchboard 57 95 999

Portugal

International Access Code: 00

Country Code: 351

Website: support.euro.dell.com

E-mail: support.euro.dell.com/pt/en/emaildell/

Technical Support 707200149

Customer Care 800 300 413

Sales 800 300 410 or 800 300 411 or 800 300 412 or 21 422 07 10

Fax 21 424 01 12

Puerto Rico General Support 1-800-805-7545

St. Kitts and Nevis General Support toll-free: 1-877-441-4731

St. Lucia General Support 1-800-882-1521

St. Vincent and the Grenadines

General Support toll-free: 1-877-270-4609

Singapore (Singapore)

International Access Code: 005

Country Code: 65

Website: support.ap.dell.com

Technical Support (Dimension, Inspiron, and Electronics and Accessories) toll-free: 1800 394 7430

Technical Support (OptiPlex, Latitude, and Dell Precision) toll-free: 1800 394 7488

Technical Support (PowerApp, PowerEdge, PowerConnect, and PowerVault) toll-free: 1800 394 7478

Customer Service (Penang, Malaysia) 604 633 4949

Transaction Sales toll-free: 1 800 394 7412

Corporate Sales toll-free: 1 800 394 7419

Slovakia (Prague)

International Access Code: 00

Country Code: 421

Website: support.euro.dell.com

E-mail: czech_dell@dell.com

Technical Support 02 5441 5727

Customer Care 420 22537 2707

Fax 02 5441 8328

Tech Fax 02 5441 8328

Switchboard (Sales) 02 5441 7585

South Africa (Johannesburg)

International Access Code:

09/091

Country Code: 27

City Code: 11

Website: support.euro.dell.com

E-mail: dell_za_support@dell.com

Gold Queue 011 709 7713

Technical Support 011 709 7710

Customer Care 011 709 7707

Sales 011 709 7700

Fax 011 706 0495

Switchboard 011 709 7700

Southeast Asian and Pacific Countries

Customer Technical Support, Customer Service, and Sales (Penang, Malaysia)

604 633 4810

Spain (Madrid)

International Access Code: 00

Country Code: 34

City Code: 91

Website: support.euro.dell.com

E-mail: support.euro.dell.com/es/es/emaildell/

Home and Small Business

Technical Support 902 100 130

Customer Care 902 118 540

Sales 902 118 541

Switchboard 902 118 541

Fax 902 118 539

Corporate

Technical Support 902 100 130

Customer Care 902 115 236

Switchboard 91 722 92 00

Fax 91 722 95 83

Sweden (Upplands Vasby)

International Access Code: 00

Country Code: 46

City Code: 8

Website: support.euro.dell.com

E-mail: support.euro.dell.com/se/sv/emaildell/

Technical Support 08 590 05 199

Relational Customer Care 08 590 05 642

Home/Small Business Customer Care 08 587 70 527

Employee Purchase Program (EPP) Support 20 140 14 44

Technical Support Fax 08 590 05 594

Sales 08 590 05 185

Switzerland (Geneva)

International Access Code: 00

Country Code: 41

City Code: 22

Website: support.euro.dell.com

E-mail: Tech_support_central_Europe@dell.com

E-mail for French-speaking HSB and Corporate Customers: support.euro.dell.com/ch/fr/emaildell/

Technical Support (Home and Small Business) 0844 811 411

Technical Support (Corporate) 0844 822 844

Customer Care (Home and Small Business) 0848 802 202

Customer Care (Corporate) 0848 821 721

Fax 022 799 01 90

Switchboard 022 799 01 01

Taiwan

International Access Code: 002

Country Code: 886

Website: support.ap.dell.com

E-mail: ap_support@dell.com

Technical Support (OptiPlex, Latitude, Inspiron, Dimension, and Electronics and Accessories)

toll-free: 00801 86 1011

Technical Support (PowerApp, PowerEdge, PowerConnect, and PowerVault) toll-free: 00801 60 1256

Transaction Sales toll-free: 00801 65 1228

Corporate Sales toll-free: 00801 651 227

Thailand

International Access Code: 001

Country Code: 66

Website: support.ap.dell.com

Technical Support (OptiPlex, Latitude, and Dell Precision) toll-free: 1800 0060 07

Technical Support (PowerApp, PowerEdge, PowerConnect, and PowerVault) toll-free: 1800 0600 09

Customer Service (Penang, Malaysia) 604 633 4949

Corporate Sales toll-free: 1800 006 009

Transaction Sales toll-free: 1800 006 006

Trinidad/Tobago General Support 1-800-805-8035

Turks and Caicos Islands General Support toll-free: 1-866-540-3355

U.K. (Bracknell)

International Access Code: 00

Country Code: 44

City Code: 1344

Website: support.euro.dell.com

Customer Care website: support.euro.dell.com/uk/en/ECare/Form/Home.asp

E-mail: dell_direct_support@dell.com

Technical Support (Corporate/Preferred Accounts/PAD [1000+ employees]) 0870 908 0500

Technical Support (direct and general) 0870 908 0800

Global Accounts Customer Care 01344 373 186

Home and Small Business Customer Care 0870 906 0010

Corporate Customer Care 01344 373 185

Preferred Accounts (5005000 employees) Customer Care 0870 906 0010

Central Government Customer Care 01344 373 193

Local Government & Education Customer Care 01344 373 199

Health Customer Care 01344 373 194

Home and Small Business Sales 0870 907 4000

Corporate/Public Sector Sales 01344 860 456

Home and Small Business Fax 0870 907 4006

Uruguay General Support toll-free: 000-413-598-2521

Automated Order-Status Service toll-free: 1-800-433-9014

AutoTech (portable and desktop computers) toll-free: 1-800-247-9362

Consumer (Home and Home Office)

Technical Support toll-free: 1-800-624-9896

Customer Service toll-free: 1-800-624-9897

DellNet Service and Support toll-free: 1-877-Dellnet

Back to Contents Page

U.S.A. (Austin, Texas)

International Access Code: 011

Country Code: 1

(1-877-335-5638)

Employee Purchase Program (EPP) Customers toll-free: 1-800-695-8133

Financial Services website: www.dellfinancialservices.com

Financial Services (lease/loans) toll-free: 1-877-577-3355

Financial Services (Dell Preferred Accounts [DPA]) toll-free: 1-800-283-2210

Business

Customer Service and Technical Support toll-free: 1-800-822-8965

Employee Purchase Program (EPP) Customers toll-free: 1-800-695-8133

Printers and Projectors Technical Support toll-free: 1-877-459-7298

Public (government, education, and healthcare)

Customer Service and Technical Support toll-free: 1-800-456-3355

Employee Purchase Program (EPP) Customers toll-free: 1-800-234-1490

Dell Sales

toll-free: 1-800-289-3355

or toll-free: 1-800-879-3355

Dell Outlet Store (Dell refurbished computers) toll-free: 1-888-798-7561

Software and Peripherals Sales toll-free: 1-800-671-3355

Spare Parts Sales toll-free: 1-800-357-3355

Extended Service and Warranty Sales toll-free: 1-800-247-4618

Fax toll-free: 1-800-727-8320

Dell Services for the Deaf, Hard-of-Hearing,

Manualsnet FAQs

If you want to find out how the PowerEdge Dell works, you can view and download the Dell PowerEdge 850 Server Installation Guide on the Manualsnet website.

Yes, we have the Installation Guide for Dell PowerEdge as well as other Dell manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Installation Guide should include all the details that are needed to use a Dell PowerEdge. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Dell PowerEdge 850 Server Installation Guide is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Dell PowerEdge 850 Server Installation Guide consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Dell PowerEdge 850 Server Installation Guide free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Dell PowerEdge 850 Server Installation Guide, simply download the document to your computer. Once downloaded, open the PDF file and print the Dell PowerEdge 850 Server Installation Guide as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.