Summary of Content for Dell Marvell QLogic 41xxx Adapter User's Guide PDF

Marvell. Moving Forward Faster

Third party information brought to you courtesy of Dell.

AH0054602-00 M

October 16, 2019

Cover

Users Guide Converged Network Adapters 41xxx Series

For more information, visit our website at: http://www.marvell.com Notice THIS DOCUMENT AND THE INFORMATION FURNISHED IN THIS DOCUMENT ARE PROVIDED AS IS WITHOUT ANY WARRANTY. MARVELL EXPRESSLY DISCLAIMS AND MAKES NO WARRANTIES OR GUARANTEES REGARDING THE PRODUCT, WHETHER EXPRESS, ORAL, IMPLIED, STATUTORY, ARISING BY OPERATION OF LAW, OR AS A RESULT OF USAGE OF TRADE, COURSE OF DEALING, OR COURSE OF PERFORMANCE, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE AND NON-INFRINGEMENT.

Information furnished is believed to be accurate and reliable. However, Marvell assumes no responsibility for the consequences of use of such information or for any infringement of patents or other rights of third parties that may result from its use. No license, express or implied, to any Marvell intellectual property rights is granted by this document. Marvell products are not authorized for use as critical components in medical devices, military systems, life or critical support devices, or related systems. Marvell retains the right to make changes to this document at any time, without notice.

Export Control The user or recipient of this document acknowledges that the information included in this document may be subject to laws including, but not limited to, U.S. export control laws and regulations regarding the export, re-export, transfer, diversion, or release of such information. The user or recipient must comply with all applicable laws and regulations at all times. These laws and regulations include restrictions on prohibited destinations, end users, and end uses.

Patents/Trademarks Products identified in this document may be covered by one or more Marvell patents and/or patent applications. You may not use or facilitate the use of this document in connection with any infringement or other legal analysis concerning the Marvell products disclosed herein. Marvell and the Marvell logo are registered trademarks of Marvell or its affiliates. Please visit www.marvell.com for a complete list of Marvell trademarks and any guidelines for use of such trademarks. Other names and brands may be claimed as the property of others.

Copyright Copyright 20152019. Marvell International Ltd. All rights reserved.

Users Guide Ethernet iSCSI Adapters and Ethernet FCoE Adapters

ii BC0054508-00 M

iii AH0054602-00 M

Table of Contents

Preface Supported Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvii What Is in This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvii Documentation Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix

Downloading Updates and Documentation . . . . . . . . . . . . . . . . . . . . . xxi Legal Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxii

Laser SafetyFDA Notice. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxii Agency Certification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxii

EMI and EMC Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . xxii KCC: Class A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiii VCCI: Class A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiv

Product Safety Compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiv

1 Product Overview Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Adapter Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Physical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Standards Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2 Hardware Installation System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Preinstallation Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Installing the Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

3 Driver Installation Installing Linux Driver Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Installing the Linux Drivers Without RDMA . . . . . . . . . . . . . . . . . . . . . 10 Removing the Linux Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Installing Linux Drivers Using the src RPM Package . . . . . . . . . 12 Installing Linux Drivers Using the kmp/kmod RPM Package . . . 13 Installing Linux Drivers Using the TAR File. . . . . . . . . . . . . . . . . 14

iv AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

Installing the Linux Drivers with RDMA . . . . . . . . . . . . . . . . . . . . . . . . 14 Linux Driver Optional Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Linux Driver Operation Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Linux Driver Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Importing a Public Key for Secure Boot. . . . . . . . . . . . . . . . . . . . . . . . 16

Installing Windows Driver Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Installing the Windows Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Running the DUP in the GUI. . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 DUP Installation Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 DUP Installation Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Removing the Windows Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Managing Adapter Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Setting Power Management Options. . . . . . . . . . . . . . . . . . . . . . . . . . 27 Configuring the Communication Protocol to Use with QCC GUI, QCC

PowerKit, and QCS CLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Link Configuration in Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Link Control Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Link Speed and Duplex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 FEC Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Installing VMware Driver Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 VMware Drivers and Driver Packages. . . . . . . . . . . . . . . . . . . . . . . . . 32 Installing VMware Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 VMware NIC Driver Optional Parameters . . . . . . . . . . . . . . . . . . . . . . 34 VMware Driver Parameter Defaults. . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Removing the VMware Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 FCoE Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 iSCSI Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

4 Upgrading the Firmware Running the DUP by Double-Clicking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Running the DUP from a Command Line. . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Running the DUP Using the .bin File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

5 Adapter Preboot Configuration Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Displaying Firmware Image Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Configuring Device-level Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Configuring NIC Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Configuring Data Center Bridging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

v AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

Configuring FCoE Boot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Configuring iSCSI Boot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Configuring Partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

Partitioning for VMware ESXi 6.5 and ESXi 6.7 . . . . . . . . . . . . . . . . . 65

6 Boot from SAN Configuration iSCSI Boot from SAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

iSCSI Out-of-Box and Inbox Support. . . . . . . . . . . . . . . . . . . . . . . . . . 68 iSCSI Preboot Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

Setting the BIOS Boot Mode to UEFI . . . . . . . . . . . . . . . . . . . . . 69 Enabling NPAR and the iSCSI HBA . . . . . . . . . . . . . . . . . . . . . . 71 Configuring the Storage Target. . . . . . . . . . . . . . . . . . . . . . . . . . 71 Selecting the iSCSI UEFI Boot Protocol . . . . . . . . . . . . . . . . . . . 72 Configuring iSCSI Boot Options . . . . . . . . . . . . . . . . . . . . . . . . . 73 Configuring the DHCP Server to Support iSCSI Boot . . . . . . . . 85

Configuring iSCSI Boot from SAN on Windows . . . . . . . . . . . . . . . . . 89 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 Selecting the Preferred iSCSI Boot Mode . . . . . . . . . . . . . . . . . 90 Configuring iSCSI General Parameters . . . . . . . . . . . . . . . . . . . 90 Configuring the iSCSI Initiator . . . . . . . . . . . . . . . . . . . . . . . . . . 91 Configuring the iSCSI Targets . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Detecting the iSCSI LUN and Injecting the Marvell Drivers . . . . 92

Configuring iSCSI Boot from SAN on Linux . . . . . . . . . . . . . . . . . . . . 94 Configuring iSCSI Boot from SAN for RHEL 7.5 and Later . . . . 95 Configuring iSCSI Boot from SAN for SLES 12 SP3 and Later . 97 Configuring iSCSI Boot from SAN for Other Linux Distributions. 97

Configuring iSCSI Boot from SAN on VMware . . . . . . . . . . . . . . . . . . 108 Setting the UEFI Main Configuration . . . . . . . . . . . . . . . . . . . . . 108 Configuring the System BIOS for iSCSI Boot (L2) . . . . . . . . . . . 110 Mapping the CD or DVD for OS Installation . . . . . . . . . . . . . . . . 112

FCoE Boot from SAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 FCoE Out-of-Box and Inbox Support. . . . . . . . . . . . . . . . . . . . . . . . . . 114 FCoE Preboot Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114

Specifying the BIOS Boot Protocol . . . . . . . . . . . . . . . . . . . . . . . 114 Configuring Adapter UEFI Boot Mode . . . . . . . . . . . . . . . . . . . . 115

Configuring FCoE Boot from SAN on Windows . . . . . . . . . . . . . . . . . 120 Windows Server 2012 R2 and 2016 FCoE Boot Installation . . . 120 Configuring FCoE on Windows . . . . . . . . . . . . . . . . . . . . . . . . . 121 FCoE Crash Dump on Windows. . . . . . . . . . . . . . . . . . . . . . . . . 121

vi AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

Injecting (Slipstreaming) Adapter Drivers into Windows Image Files. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122

Configuring FCoE Boot from SAN on Linux . . . . . . . . . . . . . . . . . . . . 122 Prerequisites for Linux FCoE Boot from SAN. . . . . . . . . . . . . . . 122 Configuring Linux FCoE Boot from SAN . . . . . . . . . . . . . . . . . . 123

Configuring FCoE Boot from SAN on VMware . . . . . . . . . . . . . . . . . . 123 Injecting (Slipstreaming) ESXi Adapter Drivers into Image Files 123 Installing the Customized ESXi ISO . . . . . . . . . . . . . . . . . . . . . . 124

7 RoCE Configuration Supported Operating Systems and OFED . . . . . . . . . . . . . . . . . . . . . . . . . . 127 Planning for RoCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 Preparing the Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 Preparing the Ethernet Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129

Configuring the Cisco Nexus 6000 Ethernet Switch . . . . . . . . . . . . . . 129 Configuring the Dell Z9100 Ethernet Switch for RoCE . . . . . . . . . . . . 131

Configuring RoCE on the Adapter for Windows Server . . . . . . . . . . . . . . . . 133 Viewing RDMA Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 Configuring RoCE for SR-IOV VF Devices (VF RDMA) . . . . . . . . . . . 141

Configuration Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149

Configuring RoCE on the Adapter for Linux . . . . . . . . . . . . . . . . . . . . . . . . . 150 RoCE Configuration for RHEL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 RoCE Configuration for SLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 Verifying the RoCE Configuration on Linux . . . . . . . . . . . . . . . . . . . . . 152 vLAN Interfaces and GID Index Values . . . . . . . . . . . . . . . . . . . . . . . . 154 RoCE v2 Configuration for Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155

Identifying the RoCE v2 GID Index or Address . . . . . . . . . . . . . 155 Verifying the RoCE v1 or RoCE v2 GID Index and Address

from sys and class Parameters . . . . . . . . . . . . . . . . . . . . . . . . 156 Verifying the RoCE v1 or RoCE v2 Function Through

perftest Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 Configuring RoCE for SR-IOV VF Devices (VF RDMA) . . . . . . . . . . . 160

Enumerating VFs for L2 and RDMA . . . . . . . . . . . . . . . . . . . . . . 161 Number of VFs Supported for RDMA . . . . . . . . . . . . . . . . . . . . . 163

Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 Configuring RoCE on the Adapter for VMware ESX . . . . . . . . . . . . . . . . . . 164

Configuring RDMA Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 Configuring MTU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166

vii AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

RoCE Mode and Statistics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166 Configuring a Paravirtual RDMA Device (PVRDMA). . . . . . . . . . . . . . 167

Configuring DCQCN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 DCQCN Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 DCQCN Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172 DCB-related Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 Global Settings on RDMA Traffic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173

Setting vLAN Priority on RDMA Traffic . . . . . . . . . . . . . . . . . . . . 173 Setting ECN on RDMA Traffic. . . . . . . . . . . . . . . . . . . . . . . . . . . 173 Setting DSCP on RDMA Traffic . . . . . . . . . . . . . . . . . . . . . . . . . 173

Configuring DSCP-PFC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 Enabling DCQCN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174 Configuring CNP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174 DCQCN Algorithm Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174 MAC Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 Script Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176

8 iWARP Configuration Preparing the Adapter for iWARP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 Configuring iWARP on Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178 Configuring iWARP on Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182

Installing the Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 Configuring iWARP and RoCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 Detecting the Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183 Supported iWARP Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184 Running Perftest for iWARP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 Configuring NFS-RDMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186

9 iSER Configuration Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188 Configuring iSER for RHEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189 Configuring iSER for SLES 12 and Later . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 Using iSER with iWARP on RHEL and SLES. . . . . . . . . . . . . . . . . . . . . . . . 193 Optimizing Linux Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195

Configuring CPUs to Maximum Performance Mode . . . . . . . . . . . . . . 195 Configuring Kernel sysctl Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 Configuring IRQ Affinity Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 Configuring Block Device Staging . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196

viii AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

Configuring iSER on ESXi 6.7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 Before You Begin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 Configuring iSER for ESXi 6.7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197

10 iSCSI Configuration iSCSI Boot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 iSCSI Offload in Windows Server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200

Installing Marvell Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201 Installing the Microsoft iSCSI Initiator . . . . . . . . . . . . . . . . . . . . . . . . . 201 Configuring Microsoft Initiator to Use Marvells iSCSI Offload . . . . . . 201 iSCSI Offload FAQs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 Windows Server 2012 R2, 2016, and 2019 iSCSI Boot Installation . . 208 iSCSI Crash Dump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209

iSCSI Offload in Linux Environments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209 Differences from bnx2i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 Configuring qedi.ko . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 Verifying iSCSI Interfaces in Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . 210

11 FCoE Configuration Configuring Linux FCoE Offload. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213

Differences Between qedf and bnx2fc. . . . . . . . . . . . . . . . . . . . . . . . . 214 Configuring qedf.ko . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214 Verifying FCoE Devices in Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215

12 SR-IOV Configuration Configuring SR-IOV on Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217 Configuring SR-IOV on Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224

Enabling IOMMU for SR-IOV in UEFI-based Linux OS Installations. . 229 Configuring SR-IOV on VMware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230

13 NVMe-oF Configuration with RDMA Installing Device Drivers on Both Servers . . . . . . . . . . . . . . . . . . . . . . . . . . 237 Configuring the Target Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238 Configuring the Initiator Server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 Preconditioning the Target Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 Testing the NVMe-oF Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242 Optimizing Performance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243

IRQ Affinity (multi_rss-affin.sh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 CPU Frequency (cpufreq.sh). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245

ix AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

14 VXLAN Configuration Configuring VXLAN in Linux. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247 Configuring VXLAN in VMware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249 Configuring VXLAN in Windows Server 2016 . . . . . . . . . . . . . . . . . . . . . . . 250

Enabling VXLAN Offload on the Adapter. . . . . . . . . . . . . . . . . . . . . . . 250 Deploying a Software Defined Network. . . . . . . . . . . . . . . . . . . . . . . . 251

15 Windows Server 2016 Configuring RoCE Interfaces with Hyper-V . . . . . . . . . . . . . . . . . . . . . . . . . 252

Creating a Hyper-V Virtual Switch with an RDMA NIC . . . . . . . . . . . . 253 Adding a vLAN ID to Host Virtual NIC . . . . . . . . . . . . . . . . . . . . . . . . . 254 Verifying If RoCE is Enabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255 Adding Host Virtual NICs (Virtual Ports) . . . . . . . . . . . . . . . . . . . . . . . 256 Mapping the SMB Drive and Running RoCE Traffic . . . . . . . . . . . . . . 256

RoCE over Switch Embedded Teaming . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258 Creating a Hyper-V Virtual Switch with SET and RDMA

Virtual NICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258 Enabling RDMA on SET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258 Assigning a vLAN ID on SET. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259 Running RDMA Traffic on SET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259

Configuring QoS for RoCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259 Configuring QoS by Disabling DCBX on the Adapter . . . . . . . . . . . . . 260 Configuring QoS by Enabling DCBX on the Adapter. . . . . . . . . . . . . . 264

Configuring VMMQ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268 Enabling VMMQ on the Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269 Creating a Virtual Machine Switch with or Without SR-IOV . . . . . . . . 269 Enabling VMMQ on the Virtual Machine Switch . . . . . . . . . . . . . . . . . 270 Getting the Virtual Machine Switch Capability. . . . . . . . . . . . . . . . . . . 271 Creating a VM and Enabling VMMQ on VMNetworkAdapters

in the VM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271 Enabling and Disabling VMMQ on a Management NIC . . . . . . . . . . . 272 Monitoring Traffic Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272

Configuring Storage Spaces Direct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 Configuring the Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273 Deploying a Hyper-Converged System . . . . . . . . . . . . . . . . . . . . . . . . 273

Deploying the Operating System . . . . . . . . . . . . . . . . . . . . . . . . 274 Configuring the Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 Configuring Storage Spaces Direct . . . . . . . . . . . . . . . . . . . . . . 276

x AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

16 Windows Server 2019 RSSv2 for Hyper-V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280

RSSv2 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280 Known Event Log Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281

Windows Server 2019 Behaviors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281 VMMQ Is Enabled by Default . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281 Inbox Driver Network Direct (RDMA) Is Disabled by Default. . . . . . . . 281

New Adapter Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 Max Queue Pairs (L2) Per VPort. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 Network Direct Technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 Virtualization Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283 VMQ and VMMQ Default Accelerations . . . . . . . . . . . . . . . . . . . . . . . 284 Single VPort Pool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284

17 Troubleshooting Troubleshooting Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286 Verifying that Current Drivers Are Loaded . . . . . . . . . . . . . . . . . . . . . . . . . . 287

Verifying Drivers in Windows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287 Verifying Drivers in Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287 Verifying Drivers in VMware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288

Testing Network Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288 Testing Network Connectivity for Windows . . . . . . . . . . . . . . . . . . . . . 288 Testing Network Connectivity for Linux . . . . . . . . . . . . . . . . . . . . . . . . 289

Microsoft Virtualization with Hyper-V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289 Linux-specific Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289 Miscellaneous Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289 Collecting Debug Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290

A Adapter LEDS

B Cables and Optical Modules Supported Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292 Tested Cables and Optical Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293 Tested Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297

C Dell Z9100 Switch Configuration

D Feature Constraints

E Revision History

Glossary

xi AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

List of Figures Figure Page 3-1 Dell Update Package Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 3-2 QLogic InstallShield Wizard: Welcome Window . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 3-3 QLogic InstallShield Wizard: License Agreement Window. . . . . . . . . . . . . . . . . . . . 20 3-4 InstallShield Wizard: Setup Type Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 3-5 InstallShield Wizard: Custom Setup Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 3-6 InstallShield Wizard: Ready to Install the Program Window . . . . . . . . . . . . . . . . . . 22 3-7 InstallShield Wizard: Completed Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 3-8 Dell Update Package Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 3-9 Setting Advanced Adapter Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 3-10 Power Management Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 3-11 Setting Driver Controlled Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 3-12 Setting the Link Speed and Duplex Property . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 3-13 Setting the FEC Mode Property . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 4-1 Dell Update Package: Splash Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 4-2 Dell Update Package: Loading New Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 4-3 Dell Update Package: Installation Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 4-4 Dell Update Package: Finish Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 4-5 DUP Command Line Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 5-1 System Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 5-2 System Setup: Device Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 5-3 Main Configuration Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 5-4 Main Configuration Page, Setting Partitioning Mode to NPAR. . . . . . . . . . . . . . . . . 46 5-5 Firmware Image Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 5-6 Device Level Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 5-7 NIC Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 5-8 System Setup: Data Center Bridging (DCB) Settings . . . . . . . . . . . . . . . . . . . . . . . 54 5-9 FCoE General Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 5-10 FCoE Target Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 5-11 iSCSI General Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 5-12 iSCSI Initiator Configuration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 5-13 iSCSI First Target Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 5-14 iSCSI Second Target Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 5-15 NIC Partitioning Configuration, Global Bandwidth Allocation . . . . . . . . . . . . . . . . . . 61 5-16 Global Bandwidth Allocation Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 5-17 Partition 1 Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 5-18 Partition 2 Configuration: FCoE Offload. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 5-19 Partition 3 Configuration: iSCSI Offload. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 5-20 Partition 4 Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 6-1 System Setup: Boot Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 6-2 System Setup: Device Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 6-3 System Setup: NIC Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 6-4 System Setup: NIC Configuration, Boot Protocol. . . . . . . . . . . . . . . . . . . . . . . . . . . 73 6-5 System Setup: iSCSI Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74

xii AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

6-6 System Setup: Selecting General Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 6-7 System Setup: iSCSI General Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 6-8 System Setup: Selecting iSCSI Initiator Parameters . . . . . . . . . . . . . . . . . . . . . . . . 77 6-9 System Setup: iSCSI Initiator Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 6-10 System Setup: Selecting iSCSI First Target Parameters . . . . . . . . . . . . . . . . . . . . . 79 6-11 System Setup: iSCSI First Target Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 6-12 System Setup: iSCSI Second Target Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . 81 6-13 System Setup: Saving iSCSI Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 6-14 System Setup: iSCSI General Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 6-15 System Setup: iSCSI General Parameters, VLAN ID . . . . . . . . . . . . . . . . . . . . . . . 89 6-16 Detecting the iSCSI LUN Using UEFI Shell (Version 2). . . . . . . . . . . . . . . . . . . . . . 93 6-17 Windows Setup: Selecting Installation Destination . . . . . . . . . . . . . . . . . . . . . . . . . 93 6-18 Windows Setup: Selecting Driver to Install . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 6-19 Integrated NIC: Device Level Configuration for VMware . . . . . . . . . . . . . . . . . . . . . 108 6-20 Integrated NIC: Partition 2 Configuration for VMware . . . . . . . . . . . . . . . . . . . . . . . 109 6-21 Integrated NIC: System BIOS, Boot Settings for VMware . . . . . . . . . . . . . . . . . . . . 110 6-22 Integrated NIC: System BIOS, Connection 1 Settings for VMware . . . . . . . . . . . . . 111 6-23 Integrated NIC: System BIOS, Connection 1 Settings (Target) for VMware . . . . . . 111 6-24 VMware iSCSI BFS: Selecting a Disk to Install . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 6-25 VMware iSCSI Boot from SAN Successful . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 6-26 System Setup: Selecting Device Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 6-27 System Setup: Device Settings, Port Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 6-28 System Setup: NIC Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 6-29 System Setup: FCoE Mode Enabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 6-30 System Setup: FCoE General Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 6-31 System Setup: FCoE General Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 6-32 ESXi-Customizer Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 6-33 Select a VMware Disk to Install . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 6-34 VMware USB Boot Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 7-1 Configuring RoCE Properties. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 7-2 Add Counters Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 7-3 Performance Monitor: 41xxx Series Adapters Counters . . . . . . . . . . . . . . . . . . . . . 138 7-4 Setting an External New Virtual Network Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 7-5 Setting SR-IOV for New Virtual Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 7-6 VM Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 7-7 Enabling VLAN to the Network Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 7-8 Enabling SR-IOV for the Network Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146 7-9 Upgrading Drivers in VM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 7-10 Enabling RDMA on the VMNIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 7-11 RDMA Traffic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 7-12 Switch Settings, Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159 7-13 Switch Settings, Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159 7-14 Configuring RDMA_CM Applications: Server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 7-15 Configuring RDMA_CM Applications: Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 7-16 Configuring a New Distributed Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168

xiii AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

7-17 Assigning a vmknic for PVRDMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169 7-18 Setting the Firewall Rule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 8-1 Windows PowerShell Command: Get-NetAdapterRdma. . . . . . . . . . . . . . . . . . . . . 179 8-2 Windows PowerShell Command: Get-NetOffloadGlobalSetting . . . . . . . . . . . . . . . 179 8-3 Perfmon: Add Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 8-4 Perfmon: Verifying iWARP Traffic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181 9-1 RDMA Ping Successful . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 9-2 iSER Portal Instances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 9-3 Iface Transport Confirmed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 9-4 Checking for New iSCSI Device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 9-5 LIO Target Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 10-1 iSCSI Initiator Properties, Configuration Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 10-2 iSCSI Initiator Node Name Change . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 10-3 iSCSI InitiatorDiscover Target Portal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203 10-4 Target Portal IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204 10-5 Selecting the Initiator IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205 10-6 Connecting to the iSCSI Target . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206 10-7 Connect To Target Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 12-1 System Setup for SR-IOV: Integrated Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 12-2 System Setup for SR-IOV: Device Level Configuration . . . . . . . . . . . . . . . . . . . . . . 218 12-3 Adapter Properties, Advanced: Enabling SR-IOV . . . . . . . . . . . . . . . . . . . . . . . . . . 219 12-4 Virtual Switch Manager: Enabling SR-IOV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 12-5 Settings for VM: Enabling SR-IOV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 12-6 Device Manager: VM with QLogic Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223 12-7 Windows PowerShell Command: Get-NetadapterSriovVf . . . . . . . . . . . . . . . . . . . . 223 12-8 System Setup: Processor Settings for SR-IOV . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 12-9 System Setup for SR-IOV: Integrated Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225 12-10 Editing the grub.conf File for SR-IOV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226 12-11 Command Output for sriov_numvfs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 12-12 Command Output for ip link show Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 12-13 RHEL68 Virtual Machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228 12-14 Add New Virtual Hardware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229 12-15 VMware Host Edit Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 13-1 NVMe-oF Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236 13-2 Subsystem NQN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 13-3 Confirm NVMe-oF Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 13-4 FIO Utility Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242 14-1 Advanced Properties: Enabling VXLAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 15-1 Enabling RDMA in Host Virtual NIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253 15-2 Hyper-V Virtual Ethernet Adapter Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254 15-3 Windows PowerShell Command: Get-VMNetworkAdapter . . . . . . . . . . . . . . . . . . . 255 15-4 Windows PowerShell Command: Get-NetAdapterRdma. . . . . . . . . . . . . . . . . . . . . 255 15-5 Add Counters Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257 15-6 Performance Monitor Shows RoCE Traffic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257 15-7 Windows PowerShell Command: New-VMSwitch . . . . . . . . . . . . . . . . . . . . . . . . . . 258

xiv AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

15-8 Windows PowerShell Command: Get-NetAdapter. . . . . . . . . . . . . . . . . . . . . . . . . . 259 15-9 Advanced Properties: Enable QoS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261 15-10 Advanced Properties: Setting VLAN ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 15-11 Advanced Properties: Enabling QoS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266 15-12 Advanced Properties: Setting VLAN ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267 15-13 Advanced Properties: Enabling Virtual Switch RSS. . . . . . . . . . . . . . . . . . . . . . . . . 269 15-14 Virtual Switch Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 15-15 Windows PowerShell Command: Get-VMSwitch. . . . . . . . . . . . . . . . . . . . . . . . . . . 271 15-16 Example Hardware Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273 16-1 RSSv2 Event Log Error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281

xv AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

List of Tables Table Page 2-1 Host Hardware Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2-2 Minimum Host Operating System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3-1 41xxx Series Adapters Linux Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 3-2 qede Driver Optional Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 3-3 Linux Driver Operation Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3-4 VMware Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 3-5 VMware NIC Driver Optional Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 3-6 VMware Driver Parameter Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 5-1 Adapter Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 6-1 iSCSI Out-of-Box and Inbox Boot from SAN Support . . . . . . . . . . . . . . . . . . . . . . . 68 6-2 iSCSI General Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 6-3 DHCP Option 17 Parameter Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 6-4 DHCP Option 43 Sub-option Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 6-5 DHCP Option 17 Sub-option Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 6-6 FCoE Out-of-Box and Inbox Boot from SAN Support . . . . . . . . . . . . . . . . . . . . . . . 114 7-1 OS Support for RoCE v1, RoCE v2, iWARP, iSER, and OFED . . . . . . . . . . . . . . . . 127 7-2 Advanced Properties for RoCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 7-3 Marvell FastLinQ RDMA Error Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 7-4 Supported Linux OSs for VF RDMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 7-5 DCQCN Algorithm Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174 13-1 Target Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238 16-1 Windows 2019 Virtualization Resources for Dell 41xxx Series Adapters. . . . . . . . . 283 16-2 Windows 2019 VMQ and VMMQ Accelerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . 284 17-1 Collecting Debug Data Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 A-1 Adapter Port Link and Activity LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 B-1 Tested Cables and Optical Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293 B-2 Switches Tested for Interoperability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297

xvi AH0054602-00 M

Preface

This preface lists the supported products, specifies the intended audience, explains the typographic conventions used in this guide, and describes legal notices.

Supported Products

This users guide describes the following Marvell products:

QL41112HFCU-DE 10Gb Converged Network Adapter, full-height bracket

QL41112HLCU-DE 10Gb Converged Network Adapter, low-profile bracket

QL41132HFRJ-DE 10Gb NIC Adapter, full-height bracket

QL41132HLRJ-DE 10Gb NIC Adapter, low-profile bracket

QL41132HQCU-DE 10Gb NIC Adapter

QL41132HQRJ-DE 10Gb NIC Adapter

QL41154HQRJ-DE 10Gb Converged Network Adapter

QL41154HQCU-DE 10Gb Converged Network Adapter

QL41162HFRJ-DE 10Gb Converged Network Adapter, full-height bracket

QL41162HLRJ-DE 10Gb Converged Network Adapter, low-profile bracket

NOTE QConvergeConsole (QCC) GUI is the only GUI management tool across all Marvell FastLinQ adapters. QLogic Control Suite (QCS) GUI is no longer supported for the FastLinQ 45000 Series Adapters and adapters based on 57xx/57xxx controllers, and has been replaced by the QCC GUI management tool. The QCC GUI provides single-pane-of-glass GUI management for all Marvell adapters. In Windows environments, when you run QCS CLI and Management Agents Installer, it will uninstall the QCS GUI (if installed on the system) and any related components from your system. To obtain the new GUI, download QCC GUI for your adapter from the Marvell Web site (see Downloading Updates and Documentation on page xxi).

Preface Intended Audience

xvii AH0054602-00 M

QL41162HMRJ-DE 10Gb Converged Network Adapter

QL41164HMCU-DE 10Gb Converged Network Adapter

QL41164HMRJ-DE 10Gb Converged Network Adapter

QL41164HFRJ-DE 10Gb Converged Network Adapter, full-height bracket

QL41164HFRJ-DE 10Gb Converged Network Adapter, low-profile bracket

QL41164HFCU-DE 10Gb Converged Network Adapter, full-height bracket

QL41232HFCU-DE 10/25Gb NIC Adapter, full-height bracket

QL41232HLCU-DE 10/25Gb NIC Adapter, low-profile bracket

QL41232HMKR-DE 10/25Gb NIC Adapter

QL41232HQCU-DE 10/25Gb NIC Adapter

QL41262HFCU-DE 10/25Gb Converged Network Adapter, full-height bracket

QL41262HLCU-DE 10/25Gb Converged Network Adapter, low-profile bracket

QL41262HMCU-DE 10/25Gb Converged Network

QL41262HMKR-DE 10/25Gb Converged Network Adapter

QL41264HMCU-DE 10/25Gb Converged Network Adapter

Intended Audience This guide is intended for system administrators and other technical staff members responsible for configuring and managing adapters installed on Dell PowerEdge servers in Windows, Linux, or VMware environments.

What Is in This Guide Following this preface, the remainder of this guide is organized into the following chapters and appendices:

Chapter 1 Product Overview provides a product functional description, a list of features, and the adapter specifications.

Chapter 2 Hardware Installation describes how to install the adapter, including the list of system requirements and a preinstallation checklist.

Chapter 3 Driver Installation describes the installation of the adapter drivers on Windows, Linux, and VMware.

Chapter 4 Upgrading the Firmware describes how to use the Dell Update Package (DUP) to upgrade the adapter firmware.

Preface What Is in This Guide

xviii AH0054602-00 M

Chapter 5 Adapter Preboot Configuration describes the preboot adapter configuration tasks using the Human Infrastructure Interface (HII) application.

Chapter 6 Boot from SAN Configuration covers boot from SAN configuration for both iSCSI and FCoE.

Chapter 7 RoCE Configuration describes how to configure the adapter, the Ethernet switch, and the host to use RDMA over converged Ethernet (RoCE).

Chapter 8 iWARP Configuration provides procedures for configuring Internet wide area RDMA protocol (iWARP) on Windows, Linux, and VMware ESXi 6.7 systems.

Chapter 9 iSER Configuration describes how to configure iSCSI Extensions for RDMA (iSER) for Linux RHEL, SLES, Ubuntu, and ESXi 6.7.

Chapter 10 iSCSI Configuration describes iSCSI boot and iSCSI offload for Windows and Linux.

Chapter 11 FCoE Configuration covers configuring Linux FCoE offload.

Chapter 12 SR-IOV Configuration provides procedures for configuring single root input/output virtualization (SR-IOV) on Windows, Linux, and VMware systems.

Chapter 13 NVMe-oF Configuration with RDMA demonstrates how to configure NVMe-oF on a simple network for 41xxx Series Adapters.

Chapter 14 VXLAN Configuration describes how to configure VXLAN for Linux, VMware, and Windows Server 2016.

Chapter 15 Windows Server 2016 describes the Windows Server 2016 features.

Chapter 16 Windows Server 2019 describes the Windows Server 2019 features.

Chapter 17 Troubleshooting describes a variety of troubleshooting methods and resources.

Appendix A Adapter LEDS lists the adapter LEDs and their significance.

Appendix B Cables and Optical Modules lists the cables, optical modules, and switches that the 41xxx Series Adapters support.

Appendix C Dell Z9100 Switch Configuration describes how to configure the Dell Z9100 switch port for 25Gbps.

Appendix D Feature Constraints provides information about feature constraints implemented in the current release.

Preface Documentation Conventions

xix AH0054602-00 M

Appendix E Revision History describes the changes made in this revision of the guide.

At the end of this guide is a glossary of terms.

Documentation Conventions This guide uses the following documentation conventions:

provides additional information.

without an alert symbol indicates the presence of a hazard that could cause damage to equipment or loss of data.

with an alert symbol indicates the presence of a hazard that could cause minor or moderate injury.

indicates the presence of a hazard that could cause serious injury or death.

Text in blue font indicates a hyperlink (jump) to a figure, table, or section in this guide, and links to Web sites are shown in underlined blue. For example:

Table 9-2 lists problems related to the user interface and remote agent.

See Installation Checklist on page 6.

For more information, visit www.marvell.com.

Text in bold font indicates user interface elements such as a menu items, buttons, check boxes, or column headings. For example:

Click the Start button, point to Programs, point to Accessories, and then click Command Prompt.

Under Notification Options, select the Warning Alarms check box.

Text in Courier font indicates a file name, directory path, or command line text. For example:

To return to the root directory from anywhere in the file structure: Type cd/ root and press ENTER.

Issue the following command: sh ./install.bin.

Key names and key strokes are indicated with UPPERCASE:

Press CTRL+P.

Press the UP ARROW key.

NOTE

CAUTION

CAUTION!

! WARNING

Preface Documentation Conventions

xx AH0054602-00 M

Text in italics indicates terms, emphasis, variables, or document titles. For example:

What are shortcut keys?

To enter the date type mm/dd/yyyy (where mm is the month, dd is the day, and yyyy is the year).

Topic titles between quotation marks identify related topics either within this manual or in the online help, which is also referred to as the help system throughout this document.

Command line interface (CLI) command syntax conventions include the following:

Plain text indicates items that you must type as shown. For example:

qaucli -pr nic -ei < > (angle brackets) indicate a variable whose value you must

specify. For example:

[ ] (square brackets) indicate an optional parameter. For example:

[ ] means specify a file name, or omit it to select the default file name.

| (vertical bar) indicates mutually exclusive options; select one option only. For example: on|off 1|2|3|4

... (ellipsis) indicates that the preceding item may be repeated. For example:

x... means one or more instances of x.

[x...] means zero or more instances of x.

(vertical ellipsis) within command example output indicate where portions of repetitious output data have been intentionally omitted.

NOTE For CLI commands only, variable names are always indicated using angle brackets instead of italics.

Preface Documentation Conventions

xxi AH0054602-00 M

( ) (parentheses) and { } (braces) are used to avoid logical ambiguity. For example:

a|b c is ambiguous {(a|b) c} means a or b, followed by c {a|(b c)} means either a, or b c

Downloading Updates and Documentation The Marvell Web site provides periodic updates to product firmware, software, and documentation.

To download Marvell firmware, software, and documentation: 1. Go to www.marvell.com.

2. Point to Support, and then under Driver Downloads, click Marvell QLogic/FastLinQ Drivers.

3. On the Drivers and Documentation page, click Adapters.

4. Click the corresponding button to search by Model or by Operating System.

5. To define a search, click an item in each selection column, and then click Go.

6. Locate the firmware, software, or document you need, and then click the items name or icon to download or open the item.

Preface Legal Notices

xxii AH0054602-00 M

Legal Notices Legal notices covered in this section include laser safety (FDA notice), agency certification, and product safety compliance.

Laser SafetyFDA Notice This product complies with DHHS Rules 21CFR Chapter I, Subchapter J. This product has been designed and manufactured according to IEC60825-1 on the safety label of laser product.

Agency Certification The following sections summarize the EMC and EMI test specifications performed on the 41xxx Series Adapters to comply with emission, immunity, and product safety standards.

EMI and EMC Requirements FCC Part 15 compliance: Class A FCC compliance information statement: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

ICES-003 Compliance: Class A This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numriqu de la classe A est conform la norme NMB-003 du Canada.

CE Mark 2014/30/EU, 2014/35/EU EMC Directive Compliance: EN55032:2012/ CISPR 32:2015 Class A

EN55024: 2010 EN61000-3-2: Harmonic Current Emission EN61000-3-3: Voltage Fluctuation and Flicker

Class 1 Laser Product

CautionClass 1 laser radiation when open Do not view directly with optical instruments

Appareil laser de classe 1

AttentionRadiation laser de classe 1 Ne pas regarder directement avec des instruments optiques

Produkt der Laser Klasse 1

VorsichtLaserstrahlung der Klasse 1 bei geffneter Abdeckung Direktes Ansehen mit optischen Instrumenten vermeiden

Luokan 1 Laserlaite VaroitusLuokan 1 lasersteily, kun laite on auki l katso suoraan laitteeseen kyttmll optisia instrumenttej

CLASS I LASER

Preface Legal Notices

xxiii AH0054602-00 M

Immunity Standards EN61000-4-2: ESD EN61000-4-3: RF Electro Magnetic Field EN61000-4-4: Fast Transient/Burst EN61000-4-5: Fast Surge Common/ Differential EN61000-4-6: RF Conducted Susceptibility EN61000-4-8: Power Frequency Magnetic Field EN61000-4-11: Voltage Dips and Interrupt

VCCI: 2015-04; Class A

AS/NZS; CISPR 32: 2015 Class A

CNS 13438: 2006 Class A

KCC: Class A Korea RRA Class A Certified

Korean Language FormatClass A

Product Name/Model: Converged Network Adapters and Intelligent Ethernet Adapters Certification holder: QLogic Corporation Manufactured date: Refer to date code listed on product Manufacturer/Country of origin: QLogic Corporation/USA

A class equipment (Business purpose info/telecommunications equipment)

As this equipment has undergone EMC registration for busi- ness purpose, the seller and/or the buyer is asked to beware of this point and in case a wrongful sale or purchase has been made, it is asked that a change to household use be made.

Preface Legal Notices

xxiv AH0054602-00 M

VCCI: Class A This is a Class A product based on the standard of the Voluntary Control Council for Interference (VCCI). If this equipment is used in a domestic environment, radio interference may occur, in which case the user may be required to take corrective actions.

Product Safety Compliance UL, cUL product safety:

UL 60950-1 (2nd Edition) A1 + A2 2014-10-14 CSA C22.2 No.60950-1-07 (2nd Edition) A1 +A2 2014-10

Use only with listed ITE or equivalent.

Complies with 21 CFR 1040.10 and 1040.11, 2014/30/EU, 2014/35/EU.

2006/95/EC low voltage directive:

TUV EN60950-1:2006+A11+A1+A12+A2 2nd Edition TUV IEC 60950-1: 2005 2nd Edition Am1: 2009 + Am2: 2013 CB

CB Certified to IEC 60950-1 2nd Edition

1 AH0054602-00 M

1 Product Overview

This chapter provides the following information for the 41xxx Series Adapters:

Functional Description

Features

Adapter Specifications on page 3

Functional Description The Marvell FastLinQ 41000 Series Adapters include 10 and 25Gb Converged Network Adapters and Intelligent Ethernet Adapters that are designed to perform accelerated data networking for server systems. The 41000 Series Adapter includes a 10/25Gb Ethernet MAC with full-duplex capability.

Using the operating systems teaming feature, you can split your network into virtual LANs (vLANs), as well as group multiple network adapters together into teams to provide network load balancing and fault tolerance. For more information about teaming, see your operating system documentation.

Features The 41xxx Series Adapters provide the following features. Some features may not be available on all adapters:

NIC partitioning (NPAR)

Single-chip solution:

10/25Gb MAC

SerDes interface for direct attach copper (DAC) transceiver connection

PCI Express (PCIe) 3.0 x8

Zero copy capable hardware

Performance features:

TCP, IP, UDP checksum offloads

TCP segmentation offload (TSO)

Large segment offload (LSO)

1Product Overview Features

2 AH0054602-00 M

Generic segment offload (GSO)

Large receive offload (LRO)

Receive segment coalescing (RSC)

Microsoft dynamic virtual machine queue (VMQ), and Linux Multiqueue

Adaptive interrupts:

Transmit/receive side scaling (TSS/RSS)

Stateless offloads for Network Virtualization using Generic Routing Encapsulation (NVGRE) and virtual LAN (VXLAN) L2/L3 GRE tunneled traffic1

Manageability:

System management bus (SMB) controller

Advanced Configuration and Power Interface (ACPI) 1.1a compliant (multiple power modes)

Network controller-sideband interface (NC-SI) support

Advanced network features:

Jumbo frames (up to 9,600 bytes). The OS and the link partner must support jumbo frames.

Virtual LANs (VLANs)

Flow control (IEEE Std 802.3x)

Logical link control (IEEE Std 802.2)

High-speed on-chip reduced instruction set computer (RISC) processor

Integrated 96KB frame buffer memory (not applicable to all models)

1,024 classification filters (not applicable to all models)

Support for multicast addresses through 128-bit hashing hardware function

Support for VMDirectPath I/O

FastLinQ 41xxx Series Adapters support VMDirectPath I/O in Linux and ESX environments. VMDirectPath I/O is not supported in Windows environments.

FastLinQ 41xxx Series Adapters can be assigned to virtual machines for PCI pass-through operation. However, due to function level dependencies, all PCIe functions associated with an adapter must be assigned to the same virtual machine. Sharing PCIe functions across the hypervisor and/or one or more virtual machines is not supported.

1 This feature requires OS or Hypervisor support to use the offloads.

1Product Overview Adapter Specifications

3 AH0054602-00 M

Serial flash NVRAM memory

PCI Power Management Interface (v1.1)

64-bit base address register (BAR) support

EM64T processor support

iSCSI and FCoE boot support2

Adapter Specifications The 41xxx Series Adapter specifications include the adapters physical characteristics and standards-compliance references.

Physical Characteristics The 41xxx Series Adapters are standard PCIe cards and ship with either a full-height or a low-profile bracket for use in a standard PCIe slot.

Standards Specifications Supported standards specifications include:

PCI Express Base Specification, rev. 3.1

PCI Express Card Electromechanical Specification, rev. 3.0

PCI Bus Power Management Interface Specification, rev. 1.2

IEEE Specifications:

802.1ad (QinQ) 802.1AX (Link Aggregation) 802.1p (Priority Encoding) 802.1q (VLAN) 802.3-2015 IEEE Standard for Ethernet (flow control) 802.3-2015 Clause 78 Energy Efficient Ethernet (EEE) 1588-2002 PTPv1 (Precision Time Protocol) 1588-2008 PTPv2

IPv4 (RFQ 791)

IPv6 (RFQ 2460)

2 Hardware support limit of SR-IOV VFs varies. The limit may be lower in some OS environments; refer to the appropriate section for your OS.

4 AH0054602-00 M

2 Hardware Installation

This chapter provides the following hardware installation information:

System Requirements

Safety Precautions on page 5

Preinstallation Checklist on page 6

Installing the Adapter on page 6

System Requirements Before you install a Marvell 41xxx Series Adapter, verify that your system meets the hardware and operating system requirements shown in Table 2-1 and Table 2-2. For a complete list of supported operating systems, visit the Marvell Web site.

Table 2-1. Host Hardware Requirements

Hardware Requirement

Architecture IA-32 or EMT64 that meets operating system requirements

PCIe

PCIe Gen 2 x8 (2x10G NIC) PCIe Gen 3 x8 (2x25G NIC) Full dual-port 25Gb bandwidth is supported on PCIe Gen 3 x8 or faster slots.

Memory 8GB RAM (minimum)

Cables and Optical Modules

The 41xxx Series Adapters have been tested for interoperability with a variety of 1G, 10G, and 25G cables and optical modules. See Tested Cables and Optical Modules on page 293.

2Hardware Installation Safety Precautions

5 AH0054602-00 M

Safety Precautions

Table 2-2. Minimum Host Operating System Requirements

Operating System Requirement

Windows Server 2012 R2, 2019

Linux RHEL 7.6, 7.7, 8.0, 8.1

SLES 12 SP4, SLES 15, SLES 15 SP1 CentOS 7.6

VMware vSphere ESXi 6.5 U3 and vSphere ESXi 6.7 U3

XenServer Citrix Hypervisor 8.0 7.0, 7.1

NOTE Table 2-2 denotes minimum host OS requirements. For a complete list of supported operating systems, visit the Marvell Web site.

! WARNING The adapter is being installed in a system that operates with voltages that can be lethal. Before you open the case of your system, observe the following precautions to protect yourself and to prevent damage to the system components. Remove any metallic objects or jewelry from your hands and wrists. Make sure to use only insulated or nonconducting tools. Verify that the system is powered OFF and is unplugged before you

touch internal components. Install or remove adapters in a static-free environment. The use of a

properly grounded wrist strap or other personal antistatic devices and an antistatic mat is strongly recommended.

2Hardware Installation Preinstallation Checklist

6 AH0054602-00 M

Preinstallation Checklist Before installing the adapter, complete the following:

1. Verify that the system meets the hardware and software requirements listed under System Requirements on page 4.

2. Verify that the system is using the latest BIOS.

3. If the system is active, shut it down.

4. When system shutdown is complete, turn off the power and unplug the power cord.

5. Remove the adapter from its shipping package and place it on an anti-static surface.

6. Check the adapter for visible signs of damage, particularly on the edge connector. Never attempt to install a damaged adapter.

Installing the Adapter The following instructions apply to installing the Marvell 41xxx Series Adapters in most systems. For details about performing these tasks, refer to the manuals that were supplied with the system.

To install the adapter: 1. Review Safety Precautions on page 5 and Preinstallation Checklist on

page 6. Before you install the adapter, ensure that the system power is OFF, the power cord is unplugged from the power outlet, and that you are following proper electrical grounding procedures.

2. Open the system case, and select the slot that matches the adapter size, which can be PCIe Gen 2 x8 or PCIe Gen 3 x8. A lesser-width adapter can be seated into a greater-width slot (x8 in an x16), but a greater-width adapter cannot be seated into a lesser-width slot (x8 in an x4). If you do not know how to identify a PCIe slot, refer to your system documentation.

3. Remove the blank cover-plate from the slot that you selected.

4. Align the adapter connector edge with the PCIe connector slot in the system.

NOTE If you acquired the adapter software from the Marvell Web site, verify the path to the adapter driver files.

2Hardware Installation Installing the Adapter

7 AH0054602-00 M

5. Applying even pressure at both corners of the card, push the adapter card into the slot until it is firmly seated. When the adapter is properly seated, the adapter port connectors are aligned with the slot opening, and the adapter faceplate is flush against the system chassis.

6. Secure the adapter with the adapter clip or screw.

7. Close the system case and disconnect any personal anti-static devices.

CAUTION Do not use excessive force when seating the card, because this may damage the system or the adapter. If you have difficulty seating the adapter, remove it, realign it, and try again.

8 AH0054602-00 M

3 Driver Installation

This chapter provides the following information about driver installation:

Installing Linux Driver Software

Installing Windows Driver Software on page 18

Installing VMware Driver Software on page 31

Installing Linux Driver Software This section describes how to install Linux drivers with or without remote direct memory access (RDMA). It also describes the Linux driver optional parameters, default values, messages, statistics, and public key for Secure Boot.

Installing the Linux Drivers Without RDMA

Installing the Linux Drivers with RDMA

Linux Driver Optional Parameters

Linux Driver Operation Defaults

Linux Driver Messages

Statistics

Importing a Public Key for Secure Boot

The 41xxx Series Adapter Linux drivers and supporting documentation are available on the Dell Support page:

dell.support.com

3Driver Installation Installing Linux Driver Software

9 AH0054602-00 M

Table 3-1 describes the 41xxx Series Adapter Linux drivers.

Install the Linux drivers using either a source Red Hat Package Manager (RPM) package or a kmod RPM package. The RHEL RPM packages are as follows: qlgc-fastlinq- . .src.rpm qlgc-fastlinq-kmp-default- . .rpm

The SLES source and kmp RPM packages are as follows: qlgc-fastlinq- . .src.rpm qlgc-fastlinq-kmp-default- . . .rpm

The following kernel module (kmod) RPM installs Linux drivers on SLES hosts running the Xen Hypervisor: qlgc-fastlinq-kmp-xen- . . .rpm The following source RPM installs the RDMA library code on RHEL and SLES hosts: qlgc-libqedr- . . .src.rpm

Table 3-1. 41xxx Series Adapters Linux Drivers

Linux Driver Description

qed The qed core driver module directly controls the firmware, handles interrupts, and pro- vides the low-level API for the protocol specific driver set. The qed interfaces with the qede, qedr, qedi, and qedf drivers. The Linux core module manages all PCI device resources (registers, host interface queues, and so on). The qed core module requires Linux kernel version 2.6.32 or later. Testing was concentrated on the x86_64 architecture.

qede Linux Ethernet driver for the 41xxx Series Adapter. This driver directly controls the hard- ware and is responsible for sending and receiving Ethernet packets on behalf of the Linux host networking stack. This driver also receives and processes device interrupts on behalf of itself (for L2 networking). The qede driver requires Linux kernel version 2.6.32 or later. Testing was concentrated on the x86_64 architecture.

qedr Linux RoCE driver that works in the OpenFabrics Enterprise Distribution (OFED) envi- ronment in conjunction with the qed core module and the qede Ethernet driver..RDMA user space applications also require that the libqedr user library is installed on the server

qedi Linux iSCSI-Offload driver for the 41xxx Series Adapters. This driver works with the Open iSCSI library.y

qedf Linux FCoE-Offload driver for the 41xxx Series Adapters. This driver works with Open FCoE library.

3Driver Installation Installing Linux Driver Software

10 AH0054602-00 M

The following source code TAR BZip2 (BZ2) compressed file installs Linux drivers on RHEL and SLES hosts: fastlinq- .tar.bz2

Installing the Linux Drivers Without RDMA To install the Linux drivers without RDMA: 1. Download the 41xxx Series Adapter Linux drivers from Dell:

dell.support.com

2. Remove the existing Linux drivers, as described in Removing the Linux Drivers on page 10.

3. Install the new Linux drivers using one of the following methods:

Installing Linux Drivers Using the src RPM Package

Installing Linux Drivers Using the kmp/kmod RPM Package

Installing Linux Drivers Using the TAR File

Removing the Linux Drivers There are two procedures for removing Linux drivers: one for a non-RDMA environment and another for an RDMA environment. Choose the procedure that matches your environment.

To remove Linux drivers in a non-RDMA environment, unload and remove the drivers: Follow the procedure that relates to the original installation method and the OS.

If the Linux drivers were installed using an RPM package, issue the following commands: rmmod qede rmmod qed depmod -a rpm -e qlgc-fastlinq-kmp-default- .

If the Linux drivers were installed using a TAR file, issue the following commands: rmmod qede

NOTE For network installations through NFS, FTP, or HTTP (using a network boot disk), you may require a driver disk that contains the qede driver. Compile the Linux boot drivers by modifying the makefile and the make environment.

3Driver Installation Installing Linux Driver Software

11 AH0054602-00 M

rmmod qed depmod -a For RHEL:

cd /lib/modules/ /extra/qlgc-fastlinq rm -rf qed.ko qede.ko qedr.ko

For SLES: cd /lib/modules/ /updates/qlgc-fastlinq rm -rf qed.ko qede.ko qedr.ko

To remove Linux drivers in a non-RDMA environment: 1. To get the path to the currently installed drivers, issue the following

command: modinfo

2. Unload and remove the Linux drivers.

If the Linux drivers were installed using an RPM package, issue the following commands: modprobe -r qede depmod -a rpm -e qlgc-fastlinq-kmp-default- .

If the Linux drivers were installed using a TAR file, issue the following commands: modprobe -r qede depmod -a

3. Delete the qed.ko, qede.ko, and qedr.ko files from the directory in which they reside. For example, in SLES, issue the following commands: cd /lib/modules/ /updates/qlgc-fastlinq rm -rf qed.ko rm -rf qede.ko rm -rf qedr.ko depmod -a

NOTE If the qedr is present, issue the modprobe -r qedr command instead.

3Driver Installation Installing Linux Driver Software

12 AH0054602-00 M

To remove Linux drivers in an RDMA environment: 1. To get the path to the installed drivers, issue the following command:

modinfo 2. Unload and remove the Linux drivers.

modprobe -r qedr modprobe -r qede modprobe -r qed depmod -a

3. Remove the driver module files:

If the drivers were installed using an RPM package, issue the following command: rpm -e qlgc-fastlinq-kmp-default- .

If the drivers were installed using a TAR file, issue the following commands for your operating system:

For RHEL: cd /lib/modules/ /extra/qlgc-fastlinq rm -rf qed.ko qede.ko qedr.ko For SLES: cd /lib/modules/ /updates/qlgc-fastlinq rm -rf qed.ko qede.ko qedr.ko

Installing Linux Drivers Using the src RPM Package To install Linux drivers using the src RPM package: 1. Issue the following at a command prompt:

rpm -ivh RPMS/ /qlgc-fastlinq- .src.rpm

2. Change the directory to the RPM path and build the binary RPM for the kernel.

NOTE For RHEL 8, install the kernel-rpm-nacros and kernel-abi-whitelists packages before building the binary RPM package.

3Driver Installation Installing Linux Driver Software

13 AH0054602-00 M

For RHEL: cd /root/rpmbuild rpmbuild -bb SPECS/fastlinq- .spec For SLES: cd /usr/src/packages rpmbuild -bb SPECS/fastlinq- .spec

3. Install the newly compiled RPM: rpm -ivh RPMS/ /qlgc-fastlinq- . .rpm

The drivers will be installed in the following paths.

For SLES: /lib/modules/ /updates/qlgc-fastlinq For RHEL: /lib/modules/ /extra/qlgc-fastlinq

4. Turn on all ethX interfaces as follows: ifconfig up

5. For SLES, use YaST to configure the Ethernet interfaces to automatically start at boot by setting a static IP address or enabling DHCP on the interface.

Installing Linux Drivers Using the kmp/kmod RPM Package To install kmod RPM package: 1. Issue the following command at a command prompt:

rpm -ivh qlgc-fastlinq- . .rpm 2. Reload the driver:

modprobe -r qede modprobe qede

NOTE The --force option may be needed on some Linux distributions if conflicts are reported.

3Driver Installation Installing Linux Driver Software

14 AH0054602-00 M

Installing Linux Drivers Using the TAR File To install Linux drivers using the TAR file: 1. Create a directory and extract the TAR files to the directory:

tar xjvf fastlinq- .tar.bz2 2. Change to the recently created directory, and then install the drivers:

cd fastlinq- make clean; make install The qed and qede drivers will be installed in the following paths.

For SLES: /lib/modules/ /updates/qlgc-fastlinq For RHEL: /lib/modules/ /extra/qlgc-fastlinq

3. Test the drivers by loading them (unload the existing drivers first, if necessary): rmmod qede rmmod qed modprobe qed modprobe qede

Installing the Linux Drivers with RDMA For information on iWARP, see Chapter 8 iWARP Configuration.

To install Linux drivers in an inbox OFED environment: 1. Download the 41xxx Series Adapter Linux drivers from the Dell:

dell.support.com

2. Configure RoCE on the adapter, as described in Configuring RoCE on the Adapter for Linux on page 150.

3. Remove existing Linux drivers, as described in Removing the Linux Drivers on page 10.

4. Install the new Linux drivers using one of the following methods:

Installing Linux Drivers Using the kmp/kmod RPM Package

Installing Linux Drivers Using the TAR File

3Driver Installation Installing Linux Driver Software

15 AH0054602-00 M

5. Install libqedr libraries to work with RDMA user space applications. The libqedr RPM is available only for inbox OFED. You must select which RDMA (RoCE, RoCEv2, or iWARP) is used in UEFI until concurrent RoCE+iWARP capability is supported in the firmware). None is enabled by default. Issue the following command: rpm ivh qlgc-libqedr- . .rpm

6. To build and install the libqedr user space library, issue the following command: 'make libqedr_install'

7. Test the drivers by loading them as follows: modprobe qedr make install_libeqdr

Linux Driver Optional Parameters Table 3-2 describes the optional parameters for the qede driver.

Table 3-2. qede Driver Optional Parameters

Parameter Description

debug Controls driver verbosity level similar to ethtool -s msglvl.

int_mode Controls interrupt mode other than MSI-X.

gro_enable Enables or disables the hardware generic receive offload (GRO) feature. This feature is similar to the kernel's software GRO, but is only performed by the device hardware.

err_flags_override A bitmap for disabling or forcing the actions taken in case of a hardware error: bit #31 An enable bit for this bitmask bit #0 Prevent hardware attentions from being reasserted bit #1 Collect debug data bit #2 Trigger a recovery process bit #3 Call WARN to get a call trace of the flow that led to the error

3Driver Installation Installing Linux Driver Software

16 AH0054602-00 M

Linux Driver Operation Defaults Table 3-3 lists the qed and qede Linux driver operation defaults.

Linux Driver Messages To set the Linux driver message detail level, issue one of the following commands:

ethtool -s msglvl

modprobe qede debug=

Where represents bits 015, which are standard Linux networking values, and bits 16 and greater are driver-specific.

Statistics To view detailed statistics and configuration information, use the ethtool utility. See the ethtool man page for more information.

Importing a Public Key for Secure Boot Linux drivers require that you import and enroll the QLogic public key to load the drivers in a Secure Boot environment. Before you begin, ensure that your server supports Secure Boot. This section provides two methods for importing and enrolling the public key.

Table 3-3. Linux Driver Operation Defaults

Operation qed Driver Default qede Driver Default

Speed Auto-negotiation with speed advertised

Auto-negotiation with speed advertised

MSI/MSI-X Enabled Enabled

Flow Control Auto-negotiation with RX and TX advertised

MTU 1500 (range is 469600)

Rx Ring Size 1000

Tx Ring Size 4078 (range is 1288191)

Coalesce Rx Microseconds 24 (range is 0255)

Coalesce Tx Microseconds 48

TSO Enabled

3Driver Installation Installing Linux Driver Software

17 AH0054602-00 M

To import and enroll the QLogic public key: 1. Download the public key from the following Web page:

http://ldriver.qlogic.com/Module-public-key/

2. To install the public key, issue the following command: # mokutil --root-pw --import cert.der Where the --root-pw option enables direct use of the root user.

3. Reboot the system.

4. Review the list of certificates that are prepared to be enrolled: # mokutil --list-new

5. Reboot the system again.

6. When the shim launches MokManager, enter the root password to confirm the certificate importation to the Machine Owner Key (MOK) list.

7. To determine if the newly imported key was enrolled: # mokutil --list-enrolled

To launch MOK manually and enroll the QLogic public key: 1. Issue the following command:

# reboot 2. In the GRUB 2 menu, press the C key.

3. Issue the following commands: chainloader $efibootdir/MokManager.efi - boot

4. Select Enroll key from disk.

5. Navigate to the cert.der file and then press ENTER.

6. Follow the instructions to enroll the key. Generally this includes pressing the 0 (zero) key and then pressing the Y key to confirm.

For additional information about Secure Boot, refer to the following Web page:

https://www.suse.com/documentation/sled-12/book_sle_admin/data/sec_uefi_ secboot.html

NOTE The firmware menu may provide more methods to add a new key to the Signature Database.

3Driver Installation Installing Windows Driver Software

18 AH0054602-00 M

Installing Windows Driver Software For information on iWARP, see Chapter 8 iWARP Configuration.

Installing the Windows Drivers

Removing the Windows Drivers

Managing Adapter Properties

Setting Power Management Options

Link Configuration in Windows

Installing the Windows Drivers Install Windows driver software using the Dell Update Package (DUP):

Running the DUP in the GUI

DUP Installation Options

DUP Installation Examples

Running the DUP in the GUI To run the DUP in the GUI: 1. Double-click the icon representing the Dell Update Package file.

NOTE The actual file name of the Dell Update Package varies.

3Driver Installation Installing Windows Driver Software

19 AH0054602-00 M

2. In the Dell Update Package window (Figure 3-1), click Install.

Figure 3-1. Dell Update Package Window

3. In the QLogic Super InstallerInstallShield Wizards Welcome window (Figure 3-2), click Next.

Figure 3-2. QLogic InstallShield Wizard: Welcome Window

3Driver Installation Installing Windows Driver Software

20 AH0054602-00 M

4. Complete the following in the wizards License Agreement window (Figure 3-3):

a. Read the End User Software License Agreement.

b. To continue, select I accept the terms in the license agreement. c. Click Next.

Figure 3-3. QLogic InstallShield Wizard: License Agreement Window

5. Complete the wizards Setup Type window (Figure 3-4) as follows:

a. Select one of the following setup types:

Click Complete to install all program features.

Click Custom to manually select the features to be installed.

b. To continue, click Next. If you clicked Complete, proceed directly to Step 6b.

3Driver Installation Installing Windows Driver Software

21 AH0054602-00 M

Figure 3-4. InstallShield Wizard: Setup Type Window

6. If you selected Custom in Step 5, complete the Custom Setup window (Figure 3-5) as follows:

a. Select the features to install. By default, all features are selected. To change a features install setting, click the icon next to it, and then select one of the following options:

This feature will be installed on the local hard driveMarks the feature for installation without affecting any of its subfeatures.

This feature, and all subfeatures, will be installed on the local hard driveMarks the feature and all of its subfeatures for installation.

This feature will not be availablePrevents the feature from being installed.

b. Click Next to continue.

3Driver Installation Installing Windows Driver Software

22 AH0054602-00 M

Figure 3-5. InstallShield Wizard: Custom Setup Window

7. In the InstallShield Wizards Ready To Install window (Figure 3-6), click Install. The InstallShield Wizard installs the QLogic Adapter drivers and Management Software Installer.

Figure 3-6. InstallShield Wizard: Ready to Install the Program Window

3Driver Installation Installing Windows Driver Software

23 AH0054602-00 M

8. When the installation is complete, the InstallShield Wizard Completed window appears (Figure 3-7). Click Finish to dismiss the installer.

Figure 3-7. InstallShield Wizard: Completed Window

9. In the Dell Update Package window (Figure 3-8), Update installer operation was successful indicates completion.

(Optional) To open the log file, click View Installation Log. The log file shows the progress of the DUP installation, any previous installed versions, any error messages, and other information about the installation.

To close the Update Package window, click CLOSE.

3Driver Installation Installing Windows Driver Software

24 AH0054602-00 M

Figure 3-8. Dell Update Package Window

DUP Installation Options To customize the DUP installation behavior, use the following command line options.

To extract only the driver components to a directory: /drivers=

To install or update only the driver components: /driveronly

(Advanced) Use the /passthrough option to send all text following /passthrough directly to the QLogic installation software of the DUP. This mode suppresses any provided GUIs, but not necessarily those of the QLogic software. /passthrough

(Advanced) To return a coded description of this DUPs supported features: /capabilities

NOTE This command requires the /s option.

NOTE This command requires the /s option.

3Driver Installation Installing Windows Driver Software

25 AH0054602-00 M

DUP Installation Examples The following examples show how to use the installation options.

To update the system silently: .exe /s To extract the update contents to the C:\mydir\ directory: .exe /s /e=C:\mydir To extract the driver components to the C:\mydir\ directory: .exe /s /drivers=C:\mydir To install only the driver components: .exe /s /driveronly To change from the default log location to C:\my path with spaces\log.txt: .exe /l="C:\my path with spaces\log.txt"

Removing the Windows Drivers To remove the Windows drivers: 1. In the Control Panel, click Programs, and then click Programs and

Features.

2. In the list of programs, select QLogic FastLinQ Driver Installer, and then click Uninstall.

3. Follow the instructions to remove the drivers.

Managing Adapter Properties To view or change the 41xxx Series Adapter properties: 1. In the Control Panel, click Device Manager. 2. On the properties of the selected adapter, click the Advanced tab.

3. On the Advanced page (Figure 3-9), select an item under Property and then change the Value for that item as needed.

NOTE This command requires the /s option.

3Driver Installation Installing Windows Driver Software

26 AH0054602-00 M

Figure 3-9. Setting Advanced Adapter Properties

3Driver Installation Installing Windows Driver Software

27 AH0054602-00 M

Setting Power Management Options You can set power management options to allow the operating system to turn off the controller to save power or to allow the controller to wake up the computer. If the device is busy (servicing a call, for example), the operating system will not shut down the device. The operating system attempts to shut down every possible device only when the computer attempts to go into hibernation. To have the controller remain on at all times, do not select the Allow the computer to turn off the device to save power check box (Figure 3-10).

Figure 3-10. Power Management Options

Configuring the Communication Protocol to Use with QCC GUI, QCC PowerKit, and QCS CLI

There are two main components of the QCC GUI, QCC PowerKit, and QCS CLI management applications: the RPC agent and the client software. An RPC agent is installed on a server, or managed host, that contains one or more Converged Network Adapters. The RPC agent collects information on the Converged Network Adapters and makes it available for retrieval from a management PC on which the client software is installed. The client software enables viewing information from the RPC agent and configuring the Converged Network Adapters.The management software includes QCC GUI and QCS CLI.

NOTE The Power Management page is available only for servers that support

power management. Do not select the Allow the computer to turn off the device to save

power check box for any adapter that is a member of a team.

3Driver Installation Installing Windows Driver Software

28 AH0054602-00 M

A communication protocol enables communication between the RPC agent and the client software. Depending on the mix of operating systems (Linux, Windows, or both) on the clients and managed hosts in your network, you can choose an appropriate utility.

For installation instructions for these management applications, refer to the following documents on the Marvell Web site:

Users Guide, QLogic Control Suite CLI (part number BC0054511-00) Users Guide, PowerShell (part number BC0054518-00) Installation Guide, QConvergeConsole GUI (part number SN0051105-00)

Link Configuration in Windows Link configuration can be done in the Windows OS with three different parameters, which are available for configuration on the Advanced tab of the Device Manager page.

3Driver Installation Installing Windows Driver Software

29 AH0054602-00 M

Link Control Mode There are two modes for controlling link configuration:

Preboot Controlled is the default mode. In this mode, the driver uses the link configuration from the device, which is configurable from preboot components. This mode ignores the link parameters on the Advanced tab.

Driver Controlled modeshould be set when you want to configure the link settings from Advanced tab of the Device Manager (as shown in Figure 3-11).

Figure 3-11. Setting Driver Controlled Mode

3Driver Installation Installing Windows Driver Software

30 AH0054602-00 M

Link Speed and Duplex The Speed & Duplex property (on the Advanced tab of the Device Manager) can be configured to any selection in the Value menu (see Figure 3-12).

Figure 3-12. Setting the Link Speed and Duplex Property

This configuration is effective only when the link control property is set to Driver controlled (see Figure 3-11).

FEC Mode FEC mode configuration at the OS level involves three driver advanced properties.

To set FEC mode: 1. Set Link Control. On the Advanced tab of the Device Manager:

a. In the Property menu, select Link control. b. In the Value menu, select Driver controlled.

See Figure 3-11 for an example.

2. Set Speed & Duplex. On the Advanced tab of the Device Manager:

a. In the Property menu, select Speed & Duplex.

b. In the Value menu, select a fixed speed.

3Driver Installation Installing VMware Driver Software

31 AH0054602-00 M

FEC mode configuration is active only when Speed & Duplex is set to a fixed speed. Setting this property to Auto Negotiation disables FEC configuration.

3. Set FEC Mode. On the Advanced tab of the Device Manager:

a. In the Property menu, select FEC Mode.

b. In the Value menu, select a valid value (see Figure 3-13).

Figure 3-13. Setting the FEC Mode Property

This property is in effect only when Step 1 and Step 2 have been completed.

All FEC modes are not valid for each media; you must know the valid modes for your specific media. If the wrong FEC mode value is set, the link goes down.

Installing VMware Driver Software This section describes the qedentv VMware ESXi driver for the 41xxx Series Adapters:

VMware Drivers and Driver Packages

Installing VMware Drivers

VMware NIC Driver Optional Parameters

3Driver Installation Installing VMware Driver Software

32 AH0054602-00 M

VMware Driver Parameter Defaults

Removing the VMware Driver

FCoE Support

iSCSI Support

VMware Drivers and Driver Packages Table 3-4 lists the VMware ESXi drivers for the protocols.

The ESXi drivers are included as individual driver packages and are not bundled together, except as noted.

The VMware drivers are available for download only from the VMware web site:

https://www.vmware.com/resources/compatibility/search.php?deviceCategory=io &details=1&keyword=QL41&page=1&display_interval=10&sortColumn=Partner& sortOrder=Asc

Install individual drivers using either:

Standard ESXi package installation commands (see Installing VMware Drivers)

Procedures in the individual driver Read Me files

Table 3-4. VMware Drivers

VMware Driver Description

qedentv Native networking driver

qedrntv Native RDMA-Offload (RoCE and RoCEv2) drivera

a For ESXi 6.5, the NIC and RoCE drivers have been packaged together and can be installed as a single offline zip bundle using standard ESXi installation commands. The recommended installation sequence is the NIC/RoCE driver package, followed by the FCoE and iSCSI driver packages (as required).

qedf Native FCoE-Offload driver

qedil Legacy iSCSI-Offload driver

qedi Native iSCSI-Offload driver (ESXi 6.7 and later)b

b For ESXi 6.7, the NIC, RoCE, and iSCSI drivers have been packaged together and can be installed as a single offline zip bundle using standard ESXi installation commands. The recommended installation sequence is the NIC/RoCE/iSCSI driver package, followed by the FCoE driver package (as required).

3Driver Installation Installing VMware Driver Software

33 AH0054602-00 M

Procedures in the following VMware KB article:

https://kb.vmware.com/selfservice/microsites/search.do?language=en_US& cmd=displayKC&externalId=2137853

You should install the NIC driver first, followed by the storage drivers.

Installing VMware Drivers You can use the driver ZIP file to install a new driver or update an existing driver. Be sure to install the entire driver set from the same driver ZIP file. Mixing drivers from different ZIP files will cause problems.

To install the VMware driver: 1. Download the VMware driver for the 41xxx Series Adapter from the VMware

support page:

www.vmware.com/support.html

2. Power up the ESX host, and then log into an account with administrator authority.

3. Use the Linux scp utility to copy the driver bundle from a local system into the /tmp directory on an ESX server with IP address 10.10.10.10. For example, issue the following command: # scp qedentv-bundle-2.0.3.zip root@10.10.10.10:/tmp You can place the file anywhere that is accessible to the ESX console shell.

4. Place the host in maintenance mode by issuing the following command: # esxcli --maintenance-mode

NOTE The maximum number of supported qedentv Ethernet interfaces on an ESXi host is 32 because the vmkernel allows only 32 interfaces to register for management callback.

3Driver Installation Installing VMware Driver Software

34 AH0054602-00 M

5. Select one of the following installation options:

Option 1: Install the driver bundle (which will install all of the driver VIBs at one time) by issuing the following command: # esxcli software vib install -d /tmp/qedentv-2.0.3.zip

Option 2: Install the .vib directly on an ESX server using either the CLI or the VMware Update Manager (VUM). To do this, unzip the driver ZIP file, and then extract the .vib file.

To install the .vib file using the CLI, issue the following command. Be sure to specify the full .vib file path:

# esxcli software vib install -v /tmp/qedentv-1.0.3.11-1OEM.550.0.0.1331820.x86_64.vib

To install the .vib file using the VUM, see the knowledge base article here:

Updating an ESXi/ESX host using VMware vCenter Update Manager 4.x and 5.x (1019545)

To upgrade the existing driver bundle: Issue the following command:

# esxcli software vib update -d /tmp/qedentv-bundle-2.0.3.zip

To upgrade an individual driver: Follow the steps for a new installation (see To install the VMware driver), except replace the command in Option 1 with the following:

# esxcli software vib update -v /tmp/qedentv-1.0.3.11-1OEM.550.0.0.1331820.x86_64.vib

VMware NIC Driver Optional Parameters Table 3-5 describes the optional parameters that can be supplied as command line arguments to the esxcfg-module command.

Table 3-5. VMware NIC Driver Optional Parameters

Parameter Description

hw_vlan Globally enables (1) or disables (0) hardware vLAN insertion and removal. Disable this parameter when the upper layer needs to send or receive fully formed packets. hw_vlan=1 is the default.

3Driver Installation Installing VMware Driver Software

35 AH0054602-00 M

num_queues Specifies the number of TX/RX queue pairs. num_queues can be 111 or one of the following: 1 allows the driver to determine the optimal number of queue pairs

(default). 0 uses the default queue. You can specify multiple values delimited by commas for multiport or multi- function configurations.

multi_rx_filters Specifies the number of RX filters per RX queue, excluding the default queue. multi_rx_filters can be 14 or one of the following values: 1 uses the default number of RX filters per queue. 0 disables RX filters.

disable_tpa Enables (0) or disables (1) the TPA (LRO) feature. disable_tpa=0 is the default.

max_vfs Specifies the number of virtual functions (VFs) per physical function (PF). max_vfs can be 0 (disabled) or 64 VFs on a single port (enabled). The 64 VF maximum support for ESXi is an OS resource allocation constraint.

RSS Specifies the number of receive side scaling queues used by the host or vir- tual extensible LAN (VXLAN) tunneled traffic for a PF. RSS can be 2, 3, 4, or one of the following values: 1 uses the default number of queues. 0 or 1 disables RSS queues. You can specify multiple values delimited by commas for multiport or multi- function configurations.

debug Specifies the level of data that the driver records in the vmkernel log file. debug can have the following values, shown in increasing amounts of data: 0x80000000 indicates Notice level. 0x40000000 indicates Information level (includes the Notice level). 0x3FFFFFFF indicates Verbose level for all driver submodules (includes

the Information and Notice levels).

auto_fw_reset Enables (1) or disables (0) the driver automatic firmware recovery capability. When this parameter is enabled, the driver attempts to recover from events such as transmit timeouts, firmware asserts, and adapter parity errors. The default is auto_fw_reset=1.

Table 3-5. VMware NIC Driver Optional Parameters (Continued)

Parameter Description

3Driver Installation Installing VMware Driver Software

36 AH0054602-00 M

VMware Driver Parameter Defaults Table 3-6 lists the VMware driver parameter default values.

vxlan_filter_en Enables (1) or disables (0) the VXLAN filtering based on the outer MAC, the inner MAC, and the VXLAN network (VNI), directly matching traffic to a spe- cific queue. The default is vxlan_filter_en=1. You can specify multiple values delimited by commas for multiport or multifunction configurations.

enable_vxlan_offld Enables (1) or disables (0) the VXLAN tunneled traffic checksum offload and TCP segmentation offload (TSO) capability. The default is enable_vxlan_offld=1. You can specify multiple values delimited by commas for multiport or multifunction configurations.

Table 3-6. VMware Driver Parameter Defaults

Parameter Default

Speed Autonegotiation with all speeds advertised. The speed parameter must be the same on all ports. If auto- negotiation is enabled on the device, all of the device ports will use autonegotiation.

Flow Control Autonegotiation with RX and TX advertised

MTU 1,500 (range 469,600)

Rx Ring Size 8,192 (range 1288,192)

Tx Ring Size 8,192 (range 1288,192)

MSI-X Enabled Transmit Send Offload (TSO)

Enabled

Large Receive Offload (LRO)

Enabled

RSS Enabled (four RX queues)

HW VLAN Enabled Number of Queues Enabled (eight RX/TX queue pairs)

Wake on LAN (WoL) Disabled

Table 3-5. VMware NIC Driver Optional Parameters (Continued)

Parameter Description

3Driver Installation Installing VMware Driver Software

37 AH0054602-00 M

Removing the VMware Driver To remove the .vib file (qedentv), issue the following command: # esxcli software vib remove --vibname qedentv

To remove the driver, issue the following command: # vmkload_mod -u qedentv

FCoE Support The Marvell VMware FCoE qedf driver included in the VMware software package supports Marvell FastLinQ FCoE converged network interface controllers (C-NICs). The driver is a kernel-mode driver that provides a translation layer between the VMware SCSI stack and the Marvell FCoE firmware and hardware. The FCoE and DCB feature set is supported on VMware ESXi 5.0 and later.

To enable FCoE-Offload mode, see the Application Note, Enabling Storage Offloads on Dell and Marvell FastLinQ 41000 Series Adapters at https://www.marvell.com/documents/5aa5otcbkr0im3ynera3/.

iSCSI Support The Marvell VMware iSCSI qedil Host Bus Adapter (HBA) driver, similar to qedf, is a kernel mode driver that provides a translation layer between the VMware SCSI stack and the Marvell iSCSI firmware and hardware. The qedil driver leverages the services provided by the VMware iscsid infrastructure for session management and IP services.

To enable iSCSI-Offload mode, see the Application Note, Enabling Storage Offloads on Dell and Marvell FastLinQ 41000 Series Adapters at https://www.marvell.com/documents/5aa5otcbkr0im3ynera3/.

3Driver Installation Installing VMware Driver Software

38 AH0054602-00 M

NOTE The iSCSI interface supported by the QL41xxx Adapters is a dependent hardware interface that relies on networking services, iSCSI configuration, and management interfaces provided by VMware. The iSCSI interface includes two components: a network adapter and an iSCSI engine on the same interface. The iSCSI engine appears on the list of storage adapters as an iSCSI adapter (vmhba). For services such as ARP and DHCP needed by iSCSI, the iSCSI vmhba uses the services of the vmnic device created by the qedil driver. The vmnic is a thin dummy implementation intended to provide L2 functionality for iSCSI to operate. Do not configure, assign to a virtual switch, or use the vmnic in any manner for carrying regular networking traffic. The actual NIC interfaces on the adapter will be claimed by the qedentv driver, which is a fully-functional NIC driver.

39 AH0054602-00 M

4 Upgrading the Firmware

This chapter provides information about upgrading the firmware using the Dell Update Package (DUP).

The firmware DUP is a Flash update utility only; it is not used for adapter configuration. You can run the firmware DUP by double-clicking the executable file. Alternatively, you can run the firmware DUP from the command line with several supported command line options.

Running the DUP by Double-Clicking

Running the DUP from a Command Line on page 41

Running the DUP Using the .bin File on page 42 (Linux only)

Running the DUP by Double-Clicking To run the firmware DUP by double-clicking the executable file: 1. Double-click the icon representing the firmware Dell Update Package file.

2. The Dell Update Package splash screen appears, as shown in Figure 4-1. Click Install to continue.

Figure 4-1. Dell Update Package: Splash Screen

4Upgrading the Firmware Running the DUP by Double-Clicking

40 AH0054602-00 M

3. Follow the on-screen instructions. In the Warning dialog box, click Yes to continue the installation.

The installer indicates that it is loading the new firmware, as shown in Figure 4-2.

Figure 4-2. Dell Update Package: Loading New Firmware

When complete, the installer indicates the result of the installation, as shown in Figure 4-3.

Figure 4-3. Dell Update Package: Installation Results

4Upgrading the Firmware Running the DUP from a Command Line

41 AH0054602-00 M

4. Click Yes to reboot the system.

5. Click Finish to complete the installation, as shown in Figure 4-4.

Figure 4-4. Dell Update Package: Finish Installation

Running the DUP from a Command Line Running the firmware DUP from the command line, with no options specified, results in the same behavior as double-clicking the DUP icon. Note that the actual file name of the DUP will vary.

To run the firmware DUP from a command line: Issue the following command:

C:\> Network_Firmware_2T12N_WN32_ _X16.EXE

4Upgrading the Firmware Running the DUP Using the .bin File

42 AH0054602-00 M

Figure 4-5 shows the options that you can use to customize the Dell Update Package installation.

Figure 4-5. DUP Command Line Options

Running the DUP Using the .bin File The following procedure is supported only on Linux OS.

To update the DUP using the .bin file: 1. Copy the Network_Firmware_NJCX1_LN_X.Y.Z.BIN file to the system or

server.

2. Change the file type into an executable file as follows: chmod 777 Network_Firmware_NJCX1_LN_X.Y.Z.BIN

3. To start the update process, issue the following command: ./Network_Firmware_NJCX1_LN_X.Y.Z.BIN

4. After the firmware is updated, reboot the system.

4Upgrading the Firmware Running the DUP Using the .bin File

43 AH0054602-00 M

Example output from the SUT during the DUP update: ./Network_Firmware_NJCX1_LN_08.07.26.BIN Collecting inventory... Running validation... BCM57810 10 Gigabit Ethernet rev 10 (p2p1) The version of this Update Package is the same as the currently installed version. Software application name: BCM57810 10 Gigabit Ethernet rev 10 (p2p1) Package version: 08.07.26 Installed version: 08.07.26 BCM57810 10 Gigabit Ethernet rev 10 (p2p2) The version of this Update Package is the same as the currently installed version. Software application name: BCM57810 10 Gigabit Ethernet rev 10 (p2p2) Package version: 08.07.26 Installed version: 08.07.26 Continue? Y/N:Y Y entered; update was forced by user Executing update... WARNING: DO NOT STOP THIS PROCESS OR INSTALL OTHER DELL PRODUCTS WHILE UPDATE IS IN PROGRESS. THESE ACTIONS MAY CAUSE YOUR SYSTEM TO BECOME UNSTABLE! ........................................................................... Device: BCM57810 10 Gigabit Ethernet rev 10 (p2p1) Application: BCM57810 10 Gigabit Ethernet rev 10 (p2p1) Update success. Device: BCM57810 10 Gigabit Ethernet rev 10 (p2p2) Application: BCM57810 10 Gigabit Ethernet rev 10 (p2p2) Update success. Would you like to reboot your system now? Continue? Y/N:Y

44 AH0054602-00 M

5 Adapter Preboot Configuration

During the host boot process, you have the opportunity to pause and perform adapter management tasks using the Human Infrastructure Interface (HII) application. These tasks include the following:

Getting Started on page 45

Displaying Firmware Image Properties on page 48

Configuring Device-level Parameters on page 49

Configuring NIC Parameters on page 50

Configuring Data Center Bridging on page 53

Configuring FCoE Boot on page 55

Configuring iSCSI Boot on page 56

Configuring Partitions on page 61

NOTE The HII screen shots in this chapter are representative and may not match the screens that you see on your system.

5Adapter Preboot Configuration Getting Started

45 AH0054602-00 M

Getting Started To start the HII application: 1. Open the System Setup window for your platform. For information about

launching the System Setup, consult the user guide for your system.

2. In the System Setup window (Figure 5-1), select Device Settings, and then press ENTER.

Figure 5-1. System Setup

3. In the Device Settings window (Figure 5-2), select the 41xxx Series Adapter port that you want to configure, and then press ENTER.

Figure 5-2. System Setup: Device Settings

5Adapter Preboot Configuration Getting Started

46 AH0054602-00 M

The Main Configuration Page (Figure 5-3) presents the adapter management options where you can set the partitioning mode.

Figure 5-3. Main Configuration Page

4. Under Device Level Configuration, set the Partitioning Mode to NPAR to add the NIC Partitioning Configuration option to the Main Configuration Page, as shown in Figure 5-4.

Figure 5-4. Main Configuration Page, Setting Partitioning Mode to NPAR

In Figure 5-3 and Figure 5-4, the Main Configuration Page shows the following:

Firmware Image Properties (see Displaying Firmware Image Properties on page 48)

NOTE NPAR is not available on ports with a maximum speed of 1G.

5Adapter Preboot Configuration Getting Started

47 AH0054602-00 M

Device Level Configuration (see Configuring Device-level Parameters on page 49)

NIC Configuration (see Configuring NIC Parameters on page 50)

iSCSI Configuration (if iSCSI remote boot is allowed by enabling iSCSI offload in NPAR mode on the ports third partition) (see Configuring iSCSI Boot on page 56)

FCoE Configuration (if FCoE boot from SAN is allowed by enabling FCoE offload in NPAR mode on the ports second partition) (see Configuring FCoE Boot on page 55)

Data Center Bridging (DCB) Settings (see Configuring Data Center Bridging on page 53)

NIC Partitioning Configuration (if NPAR is selected on the Device Level Configuration page) (see Configuring Partitions on page 61)

In addition, the Main Configuration Page presents the adapter properties listed in Table 5-1.

Table 5-1. Adapter Properties

Adapter Property Description

Device Name Factory-assigned device name

Chip Type ASIC version

PCI Device ID Unique vendor-specific PCI device ID

PCI Address PCI device address in bus-device function format

Blink LEDs User-defined blink count for the port LED

Link Status External link status

MAC Address Manufacturer-assigned permanent device MAC address

Virtual MAC Address User-defined device MAC address

iSCSI MAC Addressa Manufacturer-assigned permanent device iSCSI Offload MAC address

iSCSI Virtual MAC Address a

User-defined device iSCSI Offload MAC address

FCoE MAC Addressb Manufacturer-assigned permanent device FCoE Offload MAC address

FCoE Virtual MAC Address b

User-defined device FCoE Offload MAC address

5Adapter Preboot Configuration Displaying Firmware Image Properties

48 AH0054602-00 M

Displaying Firmware Image Properties To view the properties for the firmware image, select Firmware Image Properties on the Main Configuration Page, and then press ENTER. The Firmware Image Properties page (Figure 5-5) specifies the following view-only data:

Family Firmware Version is the multiboot image version, which comprises several firmware component images.

MBI Version is the Marvell FastLinQ bundle image version that is active on the device.

Controller BIOS Version is the management firmware version.

EFI Driver Version is the extensible firmware interface (EFI) driver version.

L2B Firmware Version is the NIC offload firmware version for boot.

Figure 5-5. Firmware Image Properties

FCoE WWPN b Manufacturer-assigned permanent device FCoE Offload WWPN (world wide port name)

FCoE Virtual WWPN b User-defined device FCoE Offload WWPN

FCoE WWNN b Manufacturer-assigned permanent device FCoE Offload WWNN (world wide node name)

FCoE Virtual WWNN b User-defined device FCoE Offload WWNN

a This property is visible only if iSCSI Offload is enabled on the NIC Partitioning Configuration page.

b This property is visible only if FCoE Offload is enabled on the NIC Partitioning Configuration page.

Table 5-1. Adapter Properties (Continued)

Adapter Property Description

5Adapter Preboot Configuration Configuring Device-level Parameters

49 AH0054602-00 M

Configuring Device-level Parameters

Device-level configuration includes the following parameters:

Virtualization Mode NPAREP Mode

To configure device-level parameters: 1. On the Main Configuration Page, select Device Level Configuration (see

Figure 5-3 on page 46), and then press ENTER.

2. On the Device Level Configuration page, select values for the device-level parameters, as shown in Figure 5-6.

Figure 5-6. Device Level Configuration

3. For Virtualization Mode, select one of the following modes to apply to all adapter ports:

None (default) specifies that no virtualization mode is enabled. NPAR sets the adapter to switch-independent NIC partitioning mode. SR-IOV sets the adapter to SR-IOV mode. NPar + SR-IOV sets the adapter to SR-IOV over NPAR mode.

NOTE The iSCSI physical functions (PFs) are listed when the iSCSI Offload feature is enabled in NPAR mode only. The FCoE PFs are listed when the FCoE Offload feature is enabled in NPAR mode only. Not all adapter models support iSCSI Offload and FCoE Offload. Only one offload can be enabled per port, and only in NPAR mode.

NOTE QL41264HMCU-DE (part number 5V6Y4) and QL41264HMRJ-DE (part number 0D1WT) adapters show support for NPAR, SR-IOV and NPAR-EP in the Device Level Configuration, though these features are not supported on 1Gbps ports 3 and 4.

5Adapter Preboot Configuration Configuring NIC Parameters

50 AH0054602-00 M

4. NParEP Mode configures the maximum quantity of partitions per adapter. This parameter is visible when you select either NPAR or NPar + SR-IOV as the Virtualization Mode in Step 2.

Enabled allows you to configure up to 16 partitions per adapter. Disabled allows you to configures up to 8 partitions per adapter.

5. Click Back.

6. When prompted, click Yes to save the changes. Changes take effect after a system reset.

Configuring NIC Parameters NIC configuration includes setting the following parameters:

Link Speed NIC + RDMA Mode RDMA Protocol Support Boot Mode FEC Mode Energy Efficient Ethernet Virtual LAN Mode Virtual LAN ID

To configure NIC parameters: 1. On the Main Configuration Page, select NIC Configuration (Figure 5-3 on

page 46), and then click Finish.

Figure 5-7 shows the NIC Configuration page.

Figure 5-7. NIC Configuration

5Adapter Preboot Configuration Configuring NIC Parameters

51 AH0054602-00 M

2. Select one of the following Link Speed options for the selected port. Not all speed selections are available on all adapters.

Auto Negotiated enables Auto Negotiation mode on the port. FEC mode selection is not available for this speed mode.

1 Gbps enables 1GbE fixed speed mode on the port. This mode is intended only for 1GbE interfaces and should not be configured for adapter interfaces that operate at other speeds. FEC mode selection is not available for this speed mode. This mode is not available on all adapters.

10 Gbps enables 10GbE fixed speed mode on the port. This mode is not available on all adapters.

25 Gbps enables 25GbE fixed speed mode on the port. This mode is not available on all adapters.

SmartAN (Default) enables FastLinQ SmartAN link speed mode on the port. No FEC mode selection is available for this speed mode. The SmartAN setting cycles through all possible link speeds and FEC modes until a link is established. This mode is intended for use only with 25G interfaces. This mode is not available on all adapters.

3. For NIC + RDMA Mode, select either Enabled or Disabled for RDMA on the port. This setting applies to all partitions of the port, if in NPAR mode.

4. FEC Mode is visible when 25 Gbps fixed speed mode is selected as the Link Speed in Step 2. For FEC Mode, select one of the following options. Not all FEC modes are available on all adapters.

None disables all FEC modes.

Fire Code enables Fire Code (BASE-R) FEC mode.

Reed Solomon enables Reed Solomon FEC mode.

Auto enables the port to cycle through None, Fire Code, and Reed Solomon FEC modes (at that link speed) in a round-robin fashion, until a link is established.

5. The RDMA Protocol Support setting applies to all partitions of the port, if in NPAR mode. This setting appears if the NIC + RDMA Mode in Step 3 is set to Enabled. RDMA Protocol Support options include the following:

RoCE enables RoCE mode on this port.

iWARP enables iWARP mode on this port.

iWARP + RoCE enables iWARP and RoCE modes on this port. This is the default. Additional configuration for Linux is required for this option as described in Configuring iWARP and RoCE on page 182.

5Adapter Preboot Configuration Configuring NIC Parameters

52 AH0054602-00 M

6. For Boot Mode, select one of the following values:

PXE enables PXE boot.

FCoE enables FCoE boot from SAN over the hardware offload pathway. The FCoE mode is available only if FCoE Offload is enabled on the second partition in NPAR mode (see Configuring Partitions on page 61).

iSCSI enables iSCSI remote boot over the hardware offload pathway. The iSCSI mode is available only if iSCSI Offload is enabled on the third partition in NPAR mode (see Configuring Partitions on page 61).

Disabled prevents this port from being used as a remote boot source.

7. The Energy Efficient Ethernet (EEE) parameter is visible only on 100BASE-T or 10GBASE-T RJ45 interfaced adapters. Select from the following EEE options:

Disabled disables EEE on this port.

Optimal Power and Performance enables EEE in optimal power and performance mode on this port.

Maximum Power Savings enables EEE in maximum power savings mode on this port.

Maximum Performance enables EEE in maximum performance mode on this port.

8. The Virtual LAN Mode parameter applies to the entire port when in PXE remote install mode. It is not persistent after a PXE remote install finishes. Select from the following vLAN options:

Enabled enables vLAN mode on this port for PXE remote install mode.

Disabled disables vLAN mode on this port.

9. The Virtual LAN ID parameter specifies the vLAN tag ID to be used on this port for PXE remote install mode. This setting applies only when Virtual LAN Mode is enabled in the previous step.

10. Click Back.

11. When prompted, click Yes to save the changes. Changes take effect after a system reset.

5Adapter Preboot Configuration Configuring Data Center Bridging

53 AH0054602-00 M

To configure the port to use RDMA:

1. Set NIC + RDMA Mode to Enabled.

2. Click Back.

3. When prompted, click Yes to save the changes. Changes take effect after a system reset.

To configure the port's boot mode: 1. For a UEFI PXE remote installation, select PXE as the Boot Mode.

2. Click Back.

3. When prompted, click Yes to save the changes. Changes take effect after a system reset.

To configure the ports PXE remote install to use a vLAN:

1. Set the Virtual LAN Mode to Enabled.

2. In the Virtual LAN ID box, enter the number to be used.

3. Click Back.

4. When prompted, click Yes to save the changes. Changes take effect after a system reset.

Configuring Data Center Bridging The data center bridging (DCB) settings comprise the DCBX protocol and the RoCE priority.

To configure the DCB settings: 1. On the Main Configuration Page (Figure 5-3 on page 46), select Data

Center Bridging (DCB) Settings, and then click Finish.

2. On the Data Center Bridging (DCB) Settings page (Figure 5-8), select the appropriate DCBX Protocol option:

Disabled disables DCBX on this port.

NOTE Follow these steps to enable RDMA on all partitions of an NPAR mode port.

NOTE This vLAN is not persistent after the PXE remote install is finished.

5Adapter Preboot Configuration Configuring Data Center Bridging

54 AH0054602-00 M

CEE enables the legacy Converged Enhanced Ethernet (CEE) protocol DCBX mode on this port.

IEEE enables the IEEE DCBX protocol on this port.

Dynamic enables dynamic application of either the CEE or IEEE protocol to match the attached link partner.

3. On the Data Center Bridging (DCB) Settings page, enter the RoCE v1 Priority as a value from 07. This setting indicates the DCB traffic class priority number used for RoCE traffic and should match the number used by the DCB-enabled switching network for RoCE traffic. Typically, 0 is used for the default lossy traffic class, 3 is used for the FCoE traffic class, and 4 is used for the lossless iSCSI-TLV over DCB traffic class.

Figure 5-8. System Setup: Data Center Bridging (DCB) Settings

4. Click Back.

5. When prompted, click Yes to save the changes. Changes take effect after a system reset.

NOTE When DCBX is enabled, the adapter periodically sends link layer discovery protocol (LLDP) packets with a dedicated unicast address that serves as the source MAC address. This LLDP MAC address is different from the factory-assigned adapter Ethernet MAC address. If you examine the MAC address table for the switch port that is connected to the adapter, you will see two MAC addresses: one for LLDP packets and one for the adapter Ethernet interface.

5Adapter Preboot Configuration Configuring FCoE Boot

55 AH0054602-00 M

Configuring FCoE Boot

To configure the FCoE boot configuration parameters: 1. On the Main Configuration Page, select FCoE Configuration, and then

select the following as needed:

FCoE General Parameters (Figure 5-9)

FCoE Target Configuration (Figure 5-10)

2. Press ENTER.

3. Choose values for the FCoE General or FCoE Target Configuration parameters.

Figure 5-9. FCoE General Parameters

NOTE The FCoE Boot Configuration Menu is only visible if FCoE Offload Mode is enabled on the second partition in NPAR mode (see Figure 5-18 on page 64). It is not visible in non-NPAR mode. To enable FCoE-Offload mode, see the Application Note, Enabling Storage Offloads on Dell and Marvell FastLinQ 41000 Series Adapters at https://www.marvell.com/documents/5aa5otcbkr0im3ynera3/.

5Adapter Preboot Configuration Configuring iSCSI Boot

56 AH0054602-00 M

Figure 5-10. FCoE Target Configuration

4. Click Back.

5. When prompted, click Yes to save the changes. Changes take effect after a system reset.

Configuring iSCSI Boot NOTE The iSCSI Boot Configuration Menu is only visible if iSCSI Offload Mode is enabled on the third partition in NPAR mode (see Figure 5-19 on page 65). It is not visible in non-NPAR mode. To enable FCoE-Offload mode, see the Application Note, Enabling Storage Offloads on Dell and Marvell FastLinQ 41000 Series Adapters at https://www.marvell.com/documents/5aa5otcbkr0im3ynera3/.

5Adapter Preboot Configuration Configuring iSCSI Boot

57 AH0054602-00 M

To configure the iSCSI boot configuration parameters: 1. On the Main Configuration Page, select iSCSI Boot Configuration Menu,

and then select one of the following options:

iSCSI General Configuration iSCSI Initiator Configuration iSCSI First Target Configuration iSCSI Second Target Configuration

2. Press ENTER.

3. Choose values for the appropriate iSCSI configuration parameters:

iSCSI General Parameters (Figure 5-11 on page 58)

TCP/IP Parameters Via DHCP iSCSI Parameters Via DHCP CHAP Authentication CHAP Mutual Authentication IP Version ARP Redirect DHCP Request Timeout Target Login Timeout DHCP Vendor ID

iSCSI Initiator Parameters (Figure 5-12 on page 59)

IPv4 Address IPv4 Subnet Mask IPv4 Default Gateway IPv4 Primary DNS IPv4 Secondary DNS VLAN ID iSCSI Name CHAP ID CHAP Secret

iSCSI First Target Parameters (Figure 5-13 on page 59)

Connect IPv4 Address TCP Port Boot LUN iSCSI Name CHAP ID CHAP Secret

5Adapter Preboot Configuration Configuring iSCSI Boot

58 AH0054602-00 M

iSCSI Second Target Parameters (Figure 5-14 on page 60)

Connect IPv4 Address TCP Port Boot LUN iSCSI Name CHAP ID CHAP Secret

4. Click Back.

5. When prompted, click Yes to save the changes. Changes take effect after a system reset.

Figure 5-11. iSCSI General Parameters

5Adapter Preboot Configuration Configuring iSCSI Boot

59 AH0054602-00 M

Figure 5-12. iSCSI Initiator Configuration Parameters

Figure 5-13. iSCSI First Target Parameters

5Adapter Preboot Configuration Configuring iSCSI Boot

60 AH0054602-00 M

Figure 5-14. iSCSI Second Target Parameters

5Adapter Preboot Configuration Configuring Partitions

61 AH0054602-00 M

Configuring Partitions You can configure bandwidth ranges for each partition on the adapter. For information specific to partition configuration on VMware ESXi 6.5, see Partitioning for VMware ESXi 6.5 and ESXi 6.7.

To configure the maximum and minimum bandwidth allocations: 1. On the Main Configuration Page, select NIC Partitioning Configuration,

and then press ENTER.

2. On the Partitions Configuration page (Figure 5-15), select Global Bandwidth Allocation.

Figure 5-15. NIC Partitioning Configuration, Global Bandwidth Allocation

5Adapter Preboot Configuration Configuring Partitions

62 AH0054602-00 M

3. On the Global Bandwidth Allocation page (Figure 5-16), click each partition minimum and maximum TX bandwidth field for which you want to allocate bandwidth. There are eight partitions per port in dual-port mode.

Figure 5-16. Global Bandwidth Allocation Page

Partition n Minimum TX Bandwidth is the minimum transmit bandwidth of the selected partition expressed as a percentage of the maximum physical port link speed. Values can be 0100. When DCBX ETS mode is enabled, the per-traffic class DCBX ETS minimum bandwidth value is used simultaneously with the per-partition minimum TX bandwidth value.The total of the minimum TX bandwidth values of all partitions on a single port must equal 100 or be all zeros.

Setting the TX minimum bandwidth to all zeros is similar to equally dividing the available bandwidth over every active partition; however, the bandwidth is dynamically allocated over all actively sending partitions. A zero value (when one or more of the other values are set to a non-zero value) allocates a minimum of one percent to that partition, when congestion (from all of the partitions) is restricting TX bandwidth.

Partition n Maximum TX Bandwidth is the maximum transmit bandwidth of the selected partition expressed as a percentage of the maximum physical port link speed. Values can be 1100. The per-partition maximum TX bandwidth value applies regardless of the DCBX ETS mode setting.

Type a value in each selected field, and then click Back.

5Adapter Preboot Configuration Configuring Partitions

63 AH0054602-00 M

4. When prompted, click Yes to save the changes. Changes take effect after a system reset.

To configure partitions: 1. To examine a specific partition configuration, on the NIC Partitioning

Configuration page (Figure 5-15 on page 61), select Partition n Configuration. If NParEP is not enabled, only four partitions exist per port.

2. To configure the first partition, select Partition 1 Configuration to open the Partition 1 Configuration page (Figure 5-17), which shows the following parameters:

NIC Mode (always enabled) PCI Device ID PCI (bus) Address MAC Address Virtual MAC Address

If NParEP is not enabled, only four partitions per port are available. On non-offload-capable adapters, the FCoE Mode and iSCSI Mode options and information are not displayed.

Figure 5-17. Partition 1 Configuration

3. To configure the second partition, select Partition 2 Configuration to open the Partition 2 Configuration page. If FCoE Offload is present, the Partition 2 Configuration (Figure 5-18) shows the following parameters:

NIC Mode enables or disables the L2 Ethernet NIC personality on Partitions 2 and greater. To disable any of the remaining partitions, set the NIC Mode to Disabled. To disable offload-capable partitions, disable both the NIC Mode and respective offload mode.

FCoE Mode enables or disables the FCoE-Offload personality on the second partition. If you enable this mode on the second partition, you should disable NIC Mode. Because only one offload is available per port, if FCoE-Offload is enabled on the ports second partition, iSCSI-Offload cannot be enabled on the third partition of that same NPAR mode port. Not all adapters support FCoE Mode.

5Adapter Preboot Configuration Configuring Partitions

64 AH0054602-00 M

iSCSI Mode enables or disables the iSCSI-Offload personality on the third partition. If you enable this mode on the third partition, you should disable NIC Mode. Because only one offload is available per port, if iSCSI-Offload is enabled on the ports third partition, FCoE-Offload cannot be enabled on the second partition of that same NPAR mode port. Not all adapters support iSCSI Mode.

FIP MAC Address1 Virtual FIP MAC Address 1

World Wide Port Name 1

Virtual World Wide Port Name 1

World Wide Node Name 1

Virtual World Wide Node Name 1

PCI Device ID PCI (bus) Address

Figure 5-18. Partition 2 Configuration: FCoE Offload

4. To configure the third partition, select Partition 3 Configuration to open the Partition 3 Configuration page (Figure 5-19). If iSCSI Offload is present, the Partition 3 Configuration shows the following parameters:

NIC Mode (Disabled) iSCSI Offload Mode (Enabled) iSCSI Offload MAC Address2 Virtual iSCSI Offload MAC Address2

1 This parameter is only present on the second partition of an NPAR mode port of FCoE offload-capable adapters. 2 This parameter is only present on the third partition of an NPAR mode port of iSCSI offload-capable adapters.

5Adapter Preboot Configuration Configuring Partitions

65 AH0054602-00 M

PCI Device ID PCI Address

Figure 5-19. Partition 3 Configuration: iSCSI Offload

5. To configure the remaining Ethernet partitions, including the previous (if not offload-enabled), open the page for a partition 2 or greater partition (see Figure 5-20).

NIC Mode (Enabled or Disabled). When disabled, the partition is hidden such that it does not appear to the OS if fewer than the maximum quantity of partitions (or PCI PFs) are detected.

PCI Device ID

PCI Address

MAC Address

Virtual MAC Address

Figure 5-20. Partition 4 Configuration

Partitioning for VMware ESXi 6.5 and ESXi 6.7 If the following conditions exist on a system running either VMware ESXi 6.5 or ESXi 6.7, you must uninstall and reinstall the drivers:

The adapter is configured to enable NPAR with all NIC partitions.

The adapter is in Single Function mode.

The configuration is saved and the system is rebooted.

5Adapter Preboot Configuration Configuring Partitions

66 AH0054602-00 M

Storage partitions are enabled (by converting one of the NIC partitions as storage) while drivers are already installed on the system.

Partition 2 is changed to FCoE.

The configuration is saved and the system is rebooted again.

Driver re-installation is required because the storage functions may keep the vmnicX enumeration rather than vmhbaX, as shown when you issue the following command on the system:

# esxcfg-scsidevs -a vmnic4 qedf link-up fc.2000000e1ed6fa2a:2001000e1ed6fa2a (0000:19:00.2) QLogic Corp. QLogic FastLinQ QL41xxx Series 10/25 GbE Controller (FCoE) vmhba0 lsi_mr3 link-n/a sas.51866da071fa9100 (0000:18:00.0) Avago (LSI) PERC H330 Mini vmnic10 qedf link-up fc.2000000e1ef249f8:2001000e1ef249f8 (0000:d8:00.2) QLogic Corp. QLogic FastLinQ QL41xxx Series 10/25 GbE Controller (FCoE) vmhba1 vmw_ahci link-n/a sata.vmhba1 (0000:00:11.5) Intel Corporation Lewisburg SSATA Controller [AHCI mode] vmhba2 vmw_ahci link-n/a sata.vmhba2 (0000:00:17.0) Intel Corporation Lewisburg SATA Controller [AHCI mode] vmhba32 qedil online iscsi.vmhba32 QLogic FastLinQ QL41xxx Series 10/25 GbE Controller (iSCSI) vmhba33 qedil online iscsi.vmhba33 QLogic FastLinQ QL41xxx Series 10/25 GbE Controller (iSCSI)

In the preceding command output, notice that vmnic4 and vmnic10 are actually storage adapter ports. To prevent this behavior, you should enable storage functions at the same time that you configure the adapter for NPAR mode.

For example, assuming that the adapter is in Single Function mode by default, you should:

1. Enable NPAR mode.

2. Change Partition 2 to FCoE.

3. Save and reboot.

67 AH0054602-00 M

6 Boot from SAN Configuration

SAN boot enables deployment of diskless servers in an environment where the boot disk is located on storage connected to the SAN. The server (initiator) communicates with the storage device (target) through the SAN using the Marvell Converged Network Adapter (CNA) Host Bus Adapter (HBA).

To enable FCoE-Offload mode, see the Application Note, Enabling Storage Offloads on Dell and Marvell FastLinQ 41000 Series Adapters at https://www.marvell.com/documents/5aa5otcbkr0im3ynera3/.

This chapter covers boot from SAN configuration for both iSCSI and FCoE:

iSCSI Boot from SAN

FCoE Boot from SAN on page 113

iSCSI Boot from SAN Marvell 41xxx Series gigabit Ethernet (GbE) adapters support iSCSI boot to enable network boot of operating systems to diskless systems. iSCSI boot allows a Windows, Linux, or VMware operating system to boot from an iSCSI target machine located remotely over a standard IP network.

This section provides the following configuration information about iSCSI boot from SAN:

iSCSI Out-of-Box and Inbox Support

iSCSI Preboot Configuration

Configuring iSCSI Boot from SAN on Windows

Configuring iSCSI Boot from SAN on Linux

Configuring iSCSI Boot from SAN on VMware

6Boot from SAN Configuration iSCSI Boot from SAN

68 AH0054602-00 M

iSCSI Out-of-Box and Inbox Support Table 6-1 lists the operating systems inbox and out-of-box support for iSCSI boot from SAN (BFS).

iSCSI Preboot Configuration For both Windows and Linux operating systems, configure iSCSI boot with UEFI iSCSI HBA (offload path with the Marvell offload iSCSI driver). Set this option using Boot Protocol, under Port Level Configuration. To support iSCSI boot, first enable the iSCSI HBA in the UEFI HII and then set the boot protocol accordingly.

Table 6-1. iSCSI Out-of-Box and Inbox Boot from SAN Support

Out-of-Box Inbox

OS Version SW iSCSI BFS Support

Hardware Offload iSCSI BFS Support

SW iSCSI BFS Support

Hardware Offload iSCSI BFS Support

Windows 2012a

a Windows Server 2012 and 2012 R2 do not support the inbox iSCSI driver for SW or hardware offload.

Yes Yes No No

Windows 2012 R2 a Yes Yes No No

Windows 2016b

b Windows Server 2016 does not support the inbox iSCSI driver for hardware offload.

Yes Yes Yes No

Windows 2019 Yes Yes Yes Yes

RHEL 7.5 Yes Yes Yes Yes

RHEL 7.6 Yes Yes Yes Yes

RHEL 8.0 Yes Yes Yes Yes

SLES 12 SP3 Yes Yes Yes Yes

SLES 15/15 SP1 Yes Yes Yes Yes

vSphere ESXi 6.5 U3c

c ESXi out-of-box and inbox do not support native hardware offload iSCSI boot. The system will perform a SW boot and connection and then will transition to hardware offload.

Yes No Yes No

vSphere ESXi 6.7 U2c Yes No Yes No

6Boot from SAN Configuration iSCSI Boot from SAN

69 AH0054602-00 M

For both Windows and Linux operating systems, iSCSI boot can be configured to boot with two distinctive methods:

iSCSI SW (also known as non-offload path with Microsoft/Open-iSCSI initiator)

Follow the Dell BIOS guide for iSCSI software installation.

ISCSI HW (offload path with the Marvell FastLinQ offload iSCSI driver). This option can be set using Boot Mode.

iSCSI hardware installation instructions start in Enabling NPAR and the iSCSI HBA on page 71.

For VMware ESXi operating systems, only the iSCSI SW method is supported.

iSCSI preboot information in this section includes:

Setting the BIOS Boot Mode to UEFI

Enabling NPAR and the iSCSI HBA

Selecting the iSCSI UEFI Boot Protocol

Configuring the Storage Target

Configuring iSCSI Boot Options

Configuring the DHCP Server to Support iSCSI Boot

Setting the BIOS Boot Mode to UEFI To configure the boot mode: 1. Restart the system.

2. Access the System BIOS menu.

3. For the Boot Mode setting, select UEFI (see Figure 6-1).

NOTE SAN boot is supported in UEFI environment only. Make sure the system boot option is UEFI, and not legacy.

6Boot from SAN Configuration iSCSI Boot from SAN

70 AH0054602-00 M

Figure 6-1. System Setup: Boot Settings

6Boot from SAN Configuration iSCSI Boot from SAN

71 AH0054602-00 M

Enabling NPAR and the iSCSI HBA To enable NPAR and the iSCSI HBA: 1. In the System Setup, Device Settings, select the QLogic device (Figure 6-2).

Refer to the OEM user guide on accessing the PCI device configuration menu.

Figure 6-2. System Setup: Device Settings

2. Enable NPAR.

Configuring the Storage Target Configuring the storage target varies by target vendors. For information on configuring the storage target, refer to the documentation provided by the vendor.

To configure the storage target: 1. Select the appropriate procedure based on your storage target, either:

Create an storage target using software such as SANBlaze or Linux-IO (LIO) Target.

Create a vdisk or volume using a target array such as EqualLogic or EMC.

6Boot from SAN Configuration iSCSI Boot from SAN

72 AH0054602-00 M

2. Create a virtual disk.

Selecting the iSCSI UEFI Boot Protocol Before selecting the preferred boot mode, ensure that the Device Level Configuration menu setting is Enable NPAR and that the NIC Partitioning Configuration menu setting is Enable iSCSI HBA.

The Boot Mode option is listed under NIC Configuration (Figure 6-3) for the adapter, and the setting is port specific. Refer to the OEM user manual for direction on accessing the device-level configuration menu under UEFI HII.

Figure 6-3. System Setup: NIC Configuration

NOTE Boot from SAN boot is supported only in NPAR mode and is configured in UEFI, and not in legacy BIOS.

6Boot from SAN Configuration iSCSI Boot from SAN

73 AH0054602-00 M

1. On the NIC Configuration page (Figure 6-4), for the Boot Protocol option, select UEFI iSCSI HBA (requires NPAR mode).

Figure 6-4. System Setup: NIC Configuration, Boot Protocol

Configuring iSCSI Boot Options iSCSI boot configuration options include:

Static iSCSI Boot Configuration

Dynamic iSCSI Boot Configuration

Enabling CHAP Authentication

Static iSCSI Boot Configuration In a static configuration, you must enter data for the following:

Initiator IP address Initiator IQN Target parameters (obtained in Configuring the Storage Target on page 71)

For information on configuration options, see Table 6-2 on page 76.

NOTE Use the Virtual LAN Mode and Virtual LAN ID options on this page only for PXE boot. If a vLAN is needed for UEFI iSCSI HBA boot mode, see Step 3 of Static iSCSI Boot Configuration.

6Boot from SAN Configuration iSCSI Boot from SAN

74 AH0054602-00 M

To configure the iSCSI boot parameters using static configuration: 1. In the Device HII Main Configuration Page, select iSCSI Configuration

(Figure 6-5), and then press ENTER.

Figure 6-5. System Setup: iSCSI Configuration

2. On the iSCSI Configuration page, select iSCSI General Parameters (Figure 6-6), and then press ENTER.

Figure 6-6. System Setup: Selecting General Parameters

6Boot from SAN Configuration iSCSI Boot from SAN

75 AH0054602-00 M

3. On the iSCSI General Parameters page (Figure 6-7), press the DOWN ARROW key to select a parameter, and then press the ENTER key to input the following values (Table 6-2 on page 76 provides descriptions of these parameters):

TCP/IP Parameters via DHCP: Disabled iSCSI Parameters via DHCP: Disabled CHAP Authentication: As required IP Version: As required (IPv4 or IPv6) CHAP Mutual Authentication: As required DHCP Vendor ID: Not applicable for static configuration HBA Boot Mode: As required Virtual LAN ID: Default value or as required Virtual LAN Mode: As required

Figure 6-7. System Setup: iSCSI General Parameters

6Boot from SAN Configuration iSCSI Boot from SAN

76 AH0054602-00 M

4. Return to the iSCSI Configuration page, and then press the ESC key.

Table 6-2. iSCSI General Parameters

Option Description

TCP/IP Parameters via DHCP This option is specific to IPv4. Controls whether the iSCSI boot host software acquires the IP address information using DHCP (Enabled) or using a static IP configuration (Disabled).

iSCSI Parameters via DHCP Controls whether the iSCSI boot host software acquires its iSCSI target parameters using DHCP (Enabled) or through a static configuration (Disabled). The static information is entered on the iSCSI Initiator Parameters Configuration page.

CHAP Authentication Controls whether the iSCSI boot host software uses CHAP authentication when connecting to the iSCSI target. If CHAP Authentication is enabled, configure the CHAP ID and CHAP Secret on the iSCSI Initiator Parameters Configuration page.

IP Version This option is specific to IPv6. Toggles between IPv4 and IPv6. All IP settings are lost if you switch from one protocol ver- sion to another.

CHAP Mutual Authentication Controls whether the iSCSI boot host software acquires its iSCSI target parameters using DHCP (Enabled) or through a static configuration (Disabled). The static information is entered on the iSCSI Initiator Parameters Configuration page.

DHCP Vendor ID Controls how the iSCSI boot host software interprets the Vendor Class ID field used during DHCP. If the Vendor Class ID field in the DHCP offer packet matches the value in the field, the iSCSI boot host software looks into the DHCP Option 43 fields for the required iSCSI boot extensions. If DHCP is disabled, this value does not need to be set.

HBA Boot Mode Controls whether SW or Offload is enabled or disabled. For Off- load, this option is unavailable (grayed out). For information about SW (non-offload), refer to the Dell BIOS configuration.

Virtual LAN ID vLAN ID range is 14094.

Virtual LAN Mode Enables or disables vLAN.

6Boot from SAN Configuration iSCSI Boot from SAN

77 AH0054602-00 M

5. Select iSCSI Initiator Parameters (Figure 6-8), and then press ENTER.

Figure 6-8. System Setup: Selecting iSCSI Initiator Parameters

6. On the iSCSI Initiator Parameters page (Figure 6-9), select the following parameters, and then type a value for each:

IPv4* Address

Subnet Mask

IPv4* Default Gateway

IPv4* Primary DNS

IPv4* Secondary DNS

iSCSI Name. Corresponds to the iSCSI initiator name to be used by the client system.

CHAP ID

CHAP Secret

6Boot from SAN Configuration iSCSI Boot from SAN

78 AH0054602-00 M

Figure 6-9. System Setup: iSCSI Initiator Parameters

7. Return to the iSCSI Configuration page, and then press ESC.

NOTE For the preceding items with asterisks (*), note the following: The label will change to IPv6 or IPv4 (default) based on the IP

version set on the iSCSI General Parameters page (Figure 6-7 on page 75).

Carefully enter the IP address. There is no error-checking performed against the IP address to check for duplicates, incorrect segment, or network assignment.

6Boot from SAN Configuration iSCSI Boot from SAN

79 AH0054602-00 M

8. Select iSCSI First Target Parameters (Figure 6-10), and then press ENTER.

Figure 6-10. System Setup: Selecting iSCSI First Target Parameters

9. On the iSCSI First Target Parameters page, set the Connect option to Enabled for the iSCSI target.

10. Type values for the following parameters for the iSCSI target, and then press ENTER:

IPv4* Address TCP Port Boot LUN iSCSI Name CHAP ID CHAP Secret

NOTE For the preceding parameters with an asterisk (*), the label will change to IPv6 or IPv4 (default) based on IP version set on the iSCSI General Parameters page, as shown in Figure 6-11.

6Boot from SAN Configuration iSCSI Boot from SAN

80 AH0054602-00 M

Figure 6-11. System Setup: iSCSI First Target Parameters

11. Return to the iSCSI Boot Configuration page, and then press ESC.

6Boot from SAN Configuration iSCSI Boot from SAN

81 AH0054602-00 M

12. If you want to configure a second iSCSI target device, select iSCSI Second Target Parameters (Figure 6-12), and enter the parameter values as you did in Step 10. This second target is used if the first target cannot be connected to.Otherwise, proceed to Step 13.

Figure 6-12. System Setup: iSCSI Second Target Parameters

13. Press ESC once, and a second time to exit.

14. Click Yes to save changes, or follow the OEM guidelines to save the device-level configuration. For example, click Yes to confirm the setting change (Figure 6-13).

6Boot from SAN Configuration iSCSI Boot from SAN

82 AH0054602-00 M

Figure 6-13. System Setup: Saving iSCSI Changes

15. After all changes have been made, reboot the system to apply the changes to the adapters running configuration.

Dynamic iSCSI Boot Configuration In a dynamic configuration, ensure that the systems IP address and target (or initiator) information are provided by a DHCP server (see IPv4 and IPv6 configurations in Configuring the DHCP Server to Support iSCSI Boot on page 85).

Any settings for the following parameters are ignored and do not need to be cleared (with the exception of the initiator iSCSI name for IPv4, CHAP ID, and CHAP secret for IPv6):

Initiator Parameters First Target Parameters or Second Target Parameters

For information on configuration options, see Table 6-2 on page 76.

6Boot from SAN Configuration iSCSI Boot from SAN

83 AH0054602-00 M

If DHCP Option 17 is used, the target information is provided by the DHCP server, and the initiator iSCSI name is retrieved from the value programmed from the Initiator Parameters window. If no value was selected, the controller defaults to the following name: iqn.1995-05.com.qlogic.<11.22.33.44.55.66>.iscsiboot The string 11.22.33.44.55.66 corresponds to the controllers MAC address. If DHCP Option 43 (IPv4 only) is used, any settings on the following windows are ignored and do not need to be cleared:

Initiator Parameters

First Target Parameters, or Second Target Parameters

To configure the iSCSI boot parameters using dynamic configuration: On the iSCSI General Parameters page, set the following options, as shown

in Figure 6-14:

TCP/IP Parameters via DHCP: Enabled iSCSI Parameters via DHCP: Enabled CHAP Authentication: As required IP Version: As required (IPv4 or IPv6) CHAP Mutual Authentication: As required DHCP Vendor ID: As required HBA Boot Mode: As required Virtual LAN ID: As required Virtual LAN Mode: As required1

NOTE When using a DHCP server, the DNS server entries are overwritten by the values provided by the DHCP server. This override occurs even if the locally provided values are valid and the DHCP server provides no DNS server information. When the DHCP server provides no DNS server information, both the primary and secondary DNS server values are set to 0.0.0.0. When the Windows OS takes over, the Microsoft iSCSI initiator retrieves the iSCSI initiator parameters and statically configures the appropriate registries. It will overwrite whatever is configured. Because the DHCP daemon runs in the Windows environment as a user process, all TCP/IP parameters must be statically configured before the stack comes up in the iSCSI boot environment.

1 Virtual LAN Mode is not necessarily required when using a dynamic (externally provided) configuration from the DHCP server.

6Boot from SAN Configuration iSCSI Boot from SAN

84 AH0054602-00 M

Figure 6-14. System Setup: iSCSI General Parameters

Enabling CHAP Authentication Ensure that the CHAP authentication is enabled on the target.

To enable CHAP authentication: 1. Go to the iSCSI General Parameters page.

2. Set CHAP Authentication to Enabled.

3. In the Initiator Parameters window, type values for the following:

CHAP ID (up to 255 characters)

CHAP Secret (if authentication is required; must be 12 to 16 characters in length)

4. Press ESC to return to the iSCSI Boot Configuration page.

5. On the iSCSI Boot Configuration Menu, select iSCSI First Target Parameters.

6. In the iSCSI First Target Parameters window, type values used when configuring the iSCSI target:

CHAP ID (optional if two-way CHAP)

CHAP Secret (optional if two-way CHAP; must be 12 to 16 characters in length or longer)

6Boot from SAN Configuration iSCSI Boot from SAN

85 AH0054602-00 M

7. Press ESC to return to the iSCSI Boot Configuration Menu.

8. Press ESC, and then select confirm Save Configuration.

Configuring the DHCP Server to Support iSCSI Boot The DHCP server is an optional component, and is only necessary if you will be doing a dynamic iSCSI boot configuration setup (see Dynamic iSCSI Boot Configuration on page 82).

Configuring the DHCP server to support iSCSI boot differs for IPv4 and IPv6:

DHCP iSCSI Boot Configurations for IPv4

Configuring the DHCP Server

Configuring DHCP iSCSI Boot for IPv6

Configuring vLANs for iSCSI Boot

DHCP iSCSI Boot Configurations for IPv4 DHCP includes several options that provide configuration information to the DHCP client. For iSCSI boot, Marvell FastLinQ adapters support the following DHCP configurations:

DHCP Option 17, Root Path

DHCP Option 43, Vendor-specific Information

DHCP Option 17, Root Path Option 17 is used to pass the iSCSI target information to the iSCSI client.

The format of the root path, as defined in IETC RFC 4173, is: "iscsi:" ":" ":" ":" ":" " Table 6-3 lists the DHCP Option 17 parameters.

Table 6-3. DHCP Option 17 Parameter Definitions

Parameter Definition

"iscsi:" A literal string

IP address or fully qualified domain name (FQDN) of the iSCSI target

":" Separator

IP protocol used to access the iSCSI target. Because only TCP is currently supported, the protocol is 6.

Port number associated with the protocol. The standard port num- ber for iSCSI is 3260.

6Boot from SAN Configuration iSCSI Boot from SAN

86 AH0054602-00 M

DHCP Option 43, Vendor-specific Information DHCP Option 43 (vendor-specific information) provides more configuration options to the iSCSI client than does DHCP Option 17. In this configuration, three additional sub-options are provided that assign the initiator IQN to the iSCSI boot client, along with two iSCSI target IQNs that can be used for booting. The format for the iSCSI target IQN is the same as that of DHCP Option 17, while the iSCSI initiator IQN is simply the initiators IQN.

Table 6-4 lists the DHCP Option 43 sub-options.

Using DHCP Option 43 requires more configuration than DHCP Option 17, but it provides a richer environment and more configuration options. You should use DHCP Option 43 when performing dynamic iSCSI boot configuration.

Logical unit number to use on the iSCSI target. The value of the LUN must be represented in hexadecimal format. A LUN with an ID of 64 must be configured as 40 within the Option 17 parameter on the DHCP server.

Target name in either IQN or EUI format. For details on both IQN and EUI formats, refer to RFC 3720. An example IQN name is iqn.1995-05.com.QLogic:iscsi-target.

NOTE DHCP Option 43 is supported on IPv4 only.

Table 6-4. DHCP Option 43 Sub-option Definitions

Sub-option Definition

201 First iSCSI target information in the standard root path format: "iscsi:" ":" ":" ":" ": " "

202 Second iSCSI target information in the standard root path format: "iscsi: ":" ":" ":" ": " "

203 iSCSI initiator IQN

Table 6-3. DHCP Option 17 Parameter Definitions (Continued)

Parameter Definition

6Boot from SAN Configuration iSCSI Boot from SAN

87 AH0054602-00 M

Configuring the DHCP Server Configure the DHCP server to support either Option 16, 17, or 43.

Configuring DHCP iSCSI Boot for IPv6 The DHCPv6 server can provide several options, including stateless or stateful IP configuration, as well as information for the DHCPv6 client. For iSCSI boot, Marvell FastLinQ adapters support the following DHCP configurations:

DHCPv6 Option 16, Vendor Class Option

DHCPv6 Option 17, Vendor-Specific Information

DHCPv6 Option 16, Vendor Class Option DHCPv6 Option 16 (vendor class option) must be present and must contain a string that matches your configured DHCP Vendor ID parameter. The DHCP Vendor ID value is QLGC ISAN, as shown in the General Parameters of the iSCSI Boot Configuration menu.

The content of Option 16 should be <2-byte length> .

DHCPv6 Option 17, Vendor-Specific Information DHCPv6 Option 17 (vendor-specific information) provides more configuration options to the iSCSI client. In this configuration, three additional sub-options are provided that assign the initiator IQN to the iSCSI boot client, along with two iSCSI target IQNs that can be used for booting.

NOTE The format of DHCPv6 Option 16 and Option 17 are fully defined in RFC 3315. If you use Option 43, you must also configure Option 60. The value of Option 60 must match the DHCP Vendor ID value, QLGC ISAN, as shown in the iSCSI General Parameters of the iSCSI Boot Configuration page.

NOTE The DHCPv6 standard Root Path option is not yet available. Marvell suggests using Option 16 or Option 17 for dynamic iSCSI boot IPv6 support.

6Boot from SAN Configuration iSCSI Boot from SAN

88 AH0054602-00 M

Table 6-5 lists the DHCP Option 17 sub-options.

The format of Option 17 should be: <2-byte Option Number 201|202|203> <2-byte length>

Configuring vLANs for iSCSI Boot iSCSI traffic on the network may be isolated in a Layer 2 vLAN to segregate it from general traffic. If this is the case, make the iSCSI interface on the adapter a member of that vLAN.

To configure vLAN for iSCSI boot: 1. Go to the iSCSI Configuration Page for the port.

2. Select iSCSI General Parameters.

Table 6-5. DHCP Option 17 Sub-option Definitions

Sub-option Definition

201 First iSCSI target information in the standard root path format: "iscsi:"[ ]":" ":" ":" ": " "

202 Second iSCSI target information in the standard root path format: "iscsi:"[ ]":" ":" ":" ": " "

203 iSCSI initiator IQN

Brackets [ ] are required for the IPv6 addresses.

6Boot from SAN Configuration iSCSI Boot from SAN

89 AH0054602-00 M

3. Select VLAN ID to enter and set the vLAN value, as shown in Figure 6-15.

Figure 6-15. System Setup: iSCSI General Parameters, VLAN ID

Configuring iSCSI Boot from SAN on Windows Adapters support iSCSI boot to enable network boot of operating systems to diskless systems. iSCSI boot allows a Windows operating system to boot from an iSCSI target machine located remotely over a standard IP network. You can set the L4 iSCSI option (offload path with Marvell offload iSCSI driver) by opening the NIC Configuration menu and setting the Boot Protocol to UEFI iSCSI. iSCSI boot from SAN for Windows information includes the following:

Before You Begin

Selecting the Preferred iSCSI Boot Mode

Configuring iSCSI General Parameters

Configuring the iSCSI Initiator

Configuring the iSCSI Targets

Detecting the iSCSI LUN and Injecting the Marvell Drivers

6Boot from SAN Configuration iSCSI Boot from SAN

90 AH0054602-00 M

Before You Begin Before you begin configuring iSCSI boot from SAN on a Windows machine, note the following:

iSCSI boot is only supported for NPAR with NParEP Mode. Before configuring iSCSI boot:

1. Access the Device Level Configuration page.

2. Set the Virtualization Mode to Npar (NPAR).

3. Set the NParEP Mode to Enabled.

The server boot mode must be UEFI.

iSCSI boot on 41xxx Series Adapters is not supported in legacy BIOS.

Marvell recommends that you disable the Integrated RAID Controller.

Selecting the Preferred iSCSI Boot Mode To select the iSCSI boot mode on Windows: 1. On the NIC Partitioning Configuration page for a selected partition, set the

iSCSI Offload Mode to Enabled.

2. On the NIC Configuration page, set the Boot Protocol option to UEFI iSCSI HBA.

Configuring iSCSI General Parameters Configure the Marvell iSCSI boot software for either static or dynamic configuration. For configuration options available from the General Parameters window, see Table 6-2 on page 76, which lists parameters for both IPv4 and IPv6.

To set the iSCSI general parameters on Windows: 1. From the Main Configuration page, select iSCSI Configuration, and then

select iSCSI General Parameters.

2. On the iSCSI General Parameters page (see Figure 6-7 on page 75), press the DOWN ARROW key to select a parameter, and then press the ENTER key to input the following values (see Table 6-2 on page 76 provides descriptions of these parameters):

TCP/IP Parameters via DHCP: Disabled (for static iSCSI boot), or Enabled (for dynamic iSCSI boot)

iSCSI Parameters via DHCP: Disabled CHAP Authentication: As required

IP Version: As required (IPv4 or IPv6)

6Boot from SAN Configuration iSCSI Boot from SAN

91 AH0054602-00 M

Virtual LAN ID: (Optional) You can isolate iSCSI traffic on the network in a Layer 2 vLAN to segregate it from general traffic.To segregate traffic, make the iSCSI interface on the adapter a member of the Layer 2 vLAN by setting this value.

Configuring the iSCSI Initiator To set the iSCSI initiator parameters on Windows: 1. From the Main Configuration page, select iSCSI Configuration, and then

select iSCSI Initiator Parameters.

2. On the iSCSI Initiator Parameters page (see Figure 6-9 on page 78), select the following parameters, and then type a value for each:

IPv4* Address

Subnet Mask

IPv4* Default Gateway

IPv4* Primary DNS

IPv4* Secondary DNS

Virtual LAN ID: (Optional) You can isolate iSCSI traffic on the network in a Layer 2 vLAN to segregate it from general traffic.To segregate traffic, make the iSCSI interface on the adapter a member of the Layer 2 vLAN by setting this value.

iSCSI Name. Corresponds to the iSCSI initiator name to be used by the client system.

CHAP ID

CHAP Secret

3. Select iSCSI First Target Parameters (Figure 6-10 on page 79), and then press ENTER.

NOTE For the preceding items with asterisks (*), note the following: The label will change to IPv6 or IPv4 (default) based on the IP

version set on the iSCSI General Parameters page (see Figure 6-7 on page 75).

Carefully enter the IP address. There is no error-checking performed against the IP address to check for duplicates, incorrect segment, or network assignment.

6Boot from SAN Configuration iSCSI Boot from SAN

92 AH0054602-00 M

Configuring the iSCSI Targets You can set up the iSCSI first target, second target, or both at once.

To set the iSCSI target parameters on Windows: 1. From the Main Configuration page, select iSCSI Configuration, and then

select iSCSI First Target Parameters.

2. On the iSCSI First Target Parameters page, set the Connect option to Enabled for the iSCSI target.

3. Type values for the following parameters for the iSCSI target, and then press ENTER:

IPv4* Address TCP Port Boot LUN iSCSI Name CHAP ID CHAP Secret

4. If you want to configure a second iSCSI target device, select iSCSI Second Target Parameters (Figure 6-12 on page 81), and enter the parameter values as you did in Step 3. This second target is used if the first target cannot be connected to.Otherwise, proceed to Step 5.

5. In the Warning dialog box, click Yes to save the changes, or follow the OEM guidelines to save the device-level configuration.

Detecting the iSCSI LUN and Injecting the Marvell Drivers 1. Reboot the system, access the HII, and determine if the iSCSI LUN is

detected. Issue the following UEFI Shell (version 2) script command: map -r -b

NOTE For the preceding parameters with an asterisk (*), the label will change to IPv6 or IPv4 (default) based on IP version set on the iSCSI General Parameters page, as shown in Figure 6-7 on page 75.

6Boot from SAN Configuration iSCSI Boot from SAN

93 AH0054602-00 M

The output from the preceding command shown in Figure 6-16 indicates that the iSCSI LUN was detected successfully at the preboot level.

Figure 6-16. Detecting the iSCSI LUN Using UEFI Shell (Version 2)

2. On the newly detected iSCSI LUN, select an installation source such as using a WDS server, mounting the .ISO with an integrated Dell Remote Access Controller (iDRAC), or using a CD/DVD.

3. In the Windows Setup window (Figure 6-17), select the drive name on which to install the driver.

Figure 6-17. Windows Setup: Selecting Installation Destination

6Boot from SAN Configuration iSCSI Boot from SAN

94 AH0054602-00 M

4. Inject the latest Marvell drivers by mounting drivers in the virtual media:

a. Click Load driver, and then click Browse (see Figure 6-18).

Figure 6-18. Windows Setup: Selecting Driver to Install

b. Navigate to the driver location and choose the qevbd driver.

c. Choose the adapter on which to install the driver, and then click Next to continue.

5. Repeat Step 4 to load the qeios driver (Marvell L4 iSCSI driver).

6. After injecting the qevbd and qeios drivers, click Next to begin installation on the iSCSI LUN. Then follow the on-screen instructions.

The server will undergo a reboot multiple times as part of the installation process, and then will boot up from the iSCSI boot from SAN LUN.

7. If it does not automatically boot, access the Boot Menu and select the specific port boot entry to boot from the iSCSI LUN.

Configuring iSCSI Boot from SAN on Linux This section provides iSCSI boot from SAN procedures for the following Linux distributions:

Configuring iSCSI Boot from SAN for RHEL 7.5 and Later

Configuring iSCSI Boot from SAN for SLES 12 SP3 and Later

Configuring iSCSI Boot from SAN for Other Linux Distributions

6Boot from SAN Configuration iSCSI Boot from SAN

95 AH0054602-00 M

Configuring iSCSI Boot from SAN for RHEL 7.5 and Later To install RHEL 7.5 and later: 1. Boot from the RHEL 7.x installation media with the iSCSI target already

connected in UEFI. Install Red Hat Enterprise Linux 7.x Test this media & install Red Hat Enterprise 7.x Troubleshooting -->

Use the UP and DOWN keys to change the selection Press 'e' to edit the selected item or 'c' for a command prompt

2. To install an out-of-box driver, press the E key. Otherwise, proceed to Step 6.

3. Select the kernel line, and then press the E key.

4. Issue the following command, and then press ENTER. inst.dd modprobe.blacklist=qed,qede,qedr,qedi,qedf The installation process prompts you to install the out-of-box driver.

5. If required for your setup, load the FastLinQ driver update disk when prompted for additional driver disks. Otherwise, if you have no other driver update disks to install, press the C key.

6. Continue with the installation. You can skip the media test. Click Next to continue with the installation.

7. In the Configuration window, select the language to use during the installation process, and then click Continue.

8. In the Installation Summary window, click Installation Destination. The disk label is sda, indicating a single-path installation. If you configured multipath, the disk has a device mapper label.

9. In the Specialized & Network Disks section, select the iSCSI LUN.

10. Type the root users password, and then click Next to complete the installation.

11. Reboot the server, and then add the following parameters in the command line: rd.iscsi.firmware rd.driver.pre=qed,qedi (to load all drivers pre=qed,qedi,qede,qedf) selinux=0

12. After a successful system boot, edit the /etc/modprobe.d/anaconda-blacklist.conf file to remove the blacklist entry for the selected driver.

6Boot from SAN Configuration iSCSI Boot from SAN

96 AH0054602-00 M

13. Edit the /etc/default/grub file as follows:

a. Locate the string in double quotes as shown in the following example. The command line is a specific reference to help find the string. GRUB_CMDLINE_LINUX="iscsi_firmware"

b. The command line may contain other parameters that can remain. Change only the iscsi_firmware string as follows: GRUB_CMDLINE_LINUX="rd.iscsi.firmware selinux=0"

14. Create a new grub.cfg file by issuing the following command: # grub2-mkconfig -o /boot/efi/EFI/redhat/grub.cfg

15. Rebuild the ramdisk by issuing the dracut -f command, and then reboot.

NOTE When installing iSCSI BFS in Linux with a multipath I/O (MPIO) configuration and a single path active, use the following settings in the multipath.conf file: defaults { find_multipaths yes user_friendly_names yes polling_interval 5 fast_io_fail_tmo 5 dev_loss_tmo 10 checker_timeout 15 no_path_retry queue

} These suggested settings are tunable and provided as guidance for iSCSI BFS to be operational. For more information, contact the appropriate OS vendor.

6Boot from SAN Configuration iSCSI Boot from SAN

97 AH0054602-00 M

Configuring iSCSI Boot from SAN for SLES 12 SP3 and Later To install SLES 12 SP3 and later: 1. Boot from the SLES 12 SP3 installation media with the iSCSI target

pre-configured and connected in UEFI.

2. Update the latest driver package by adding the dud=1 parameter in the installer command parameter. The driver update disk is required because the necessary iSCSI drivers are not inbox.

3. Complete the installation steps specified by the SLES 12 SP3 OS.

Known Issue in DHCP Configuration In DHCP configuration for SLES 12 SP3 and later, the first boot after an OS installation may fail if the initiator IP address acquired from the DHCP server is in a different range than the target IP address. To resolve this issue, boot the OS using static configuration, update the latest iscsiuio out-of-box RPM, rebuild the initrd, and then reboot the OS using DHCP configuration. The OS should now boot successfully.

Configuring iSCSI Boot from SAN for Other Linux Distributions For distributions such as RHEL 6.9/6.10/7.2/7.3, SLES 11 SP4, and SLES 12 SP1/2, the inbox iSCSI user space utility (Open-iSCSI tools) lacks support for qedi iSCSI transport and cannot perform user space-initiated iSCSI functionality. During boot from SAN installation, you can update the qedi driver using a driver update disk (DUD). However, no interface or process exists to update userspace inbox utilities, which causes the iSCSI target login and boot from SAN installation to fail.

To overcome this limitation, perform the initial boot from SAN with the pure L2 interface (do not use hardware-offloaded iSCSI) using the following procedure during the boot from SAN.

NOTE For SLES 12 SP3 only: If the server is configured for Multi-Function mode (NPAR), you must provide the following additional parameters as part of this step: dud=1 brokenmodules=qed,qedi,qedf,qede withiscsi=1 [BOOT_IMAGE=/boot/x86_64/loader/linux dud=1 brokenmodules=qed,qedi,qedf,qede withiscsi=1]

6Boot from SAN Configuration iSCSI Boot from SAN

98 AH0054602-00 M

iSCSI offload for other distributions of Linux includes the following information:

Booting from SAN Using a Software Initiator

Migrating from Software iSCSI Installation to Offload iSCSI

Linux Multipath Considerations

Booting from SAN Using a Software Initiator To boot from SAN using a software initiator with Dell OEM Solutions:

1. Access the Dell EMC System BIOS settings.

2. Configure the initiator and target entries. For more information, refer to the Dell BIOS user guide.

3. At the beginning of the installation, pass the following boot parameter with the DUD option:

For RHEL 6.x, 7.x, and older: rd.iscsi.ibft dd No separate options are required for older distributions of RHEL.

For SLES 11 SP4 and SLES 12 SP1/SP2: ip=ibft dud=1

For the FastLinQ DUD package (for example, on RHEL 7): fastlinq-8.18.10.0-dd-rhel7u3-3.10.0_514.el7-x86_64.iso Where the DUD parameter is dd for RHEL 7.x and dud=1 for SLES 12.x.

4. Install the OS on the target LUN.

Migrating from Software iSCSI Installation to Offload iSCSI Migrate from the non-offload interface to an offload interface by following the instructions for your operating system.

Migrating to Offload iSCSI for RHEL 6.9/6.10

Migrating to Offload iSCSI for SLES 11 SP4

Migrating to Offload iSCSI for SLES 12 SP1/SP2

NOTE [[

The preceding step is required because DUDs contain qedi, which binds to the iSCSI PF. After it is bound, Open-iSCSI infrastructure fails due to unknown transport driver.

6Boot from SAN Configuration iSCSI Boot from SAN

99 AH0054602-00 M

Migrating to Offload iSCSI for RHEL 6.9/6.10

To migrate from a software iSCSI installation to an offload iSCSI for RHEL 6.9 or 6.10: 1. Boot into the iSCSI non-offload/L2 boot from SAN operating system. Issue

the following commands to install the Open-iSCSI and iscsiuio RPMs: # rpm -ivh --force qlgc-open-iscsi-2.0_873.111-1.x86_64.rpm # rpm -ivh --force iscsiuio-2.11.5.2-1.rhel6u9.x86_64.rpm

2. Edit the /etc/init.d/iscsid file, add the following command, and then save the file: modprobe -q qedi For example: echo -n $"Starting $prog: " modprobe -q iscsi_tcp modprobe -q ib_iser modprobe -q cxgb3i modprobe -q cxgb4i modprobe -q bnx2i modprobe -q be2iscsi modprobe -q qedi daemon iscsiuio

3. Open the /boot/efi/EFI/redhat/grub.conf file, make the following changes, and save the file:

Remove ifname=eth5:14:02:ec:ce:dc:6d Remove ip=ibft Add selinux=0

For example: kernel /vmlinuz-2.6.32-696.el6.x86_64 ro root=/dev/mapper/vg_prebooteit-lv_root rd_NO_LUKS iscsi_firmware LANG=en_US.UTF-8 ifname=eth5:14:02:ec:ce:dc:6d rd_NO_MD SYSFONT=latarcyrheb-sun16 crashkernel=auto rd_NO_DM rd_LVM_LV=vg_prebooteit/lv_swap ip=ibft KEYBOARDTYPE=pc KEYTABLE=us rd_LVM_LV=vg_prebooteit/lv_root rhgb quiet

NOTE To retain the original contents of the inbox RPM during installation, you must use the -ivh option (instead of the -Uvh option), followed by the --force option.

6Boot from SAN Configuration iSCSI Boot from SAN

100 AH0054602-00 M

initrd /initramfs-2.6.32-696.el6.x86_64.img

kernel /vmlinuz-2.6.32-696.el6.x86_64 ro root=/dev/mapper/vg_prebooteit-lv_root rd_NO_LUKS iscsi_firmware LANG=en_US.UTF-8 rd_NO_MD SYSFONT=latarcyrheb-sun16 crashkernel=auto rd_NO_DM rd_LVM_LV=vg_prebooteit/lv_swap KEYBOARDTYPE=pc KEYTABLE=us rd_LVM_LV=vg_prebooteit/lv_root selinux=0 initrd /initramfs-2.6.32-696.el6.x86_64.img

4. Build the initramfs file by issuing the following command: # dracut -f

5. Reboot the server, and then open the UEFI HII.

6. In the HII, disable iSCSI boot from BIOS, and then enable iSCSI HBA or boot for the adapter as follows:

a. Select the adapter port, and then select Device Level Configuration.

b. On the Device Level Configuration page, for the Virtualization Mode, select NPAR.

c. Open the NIC Partitioning Configuration page and set the iSCSI Offload Mode to Enabled. (iSCSI HBA support is on partition 3 for a two--port adapter and on partition 2 for a four-port adapter.)

d. Open the NIC Configuration menu and set the Boot Protocol to UEFI iSCSI.

e. Open the iSCSI Configuration page and configure iSCSI settings.

7. Save the configuration and reboot the server.

The OS can now boot through the offload interface.

Migrating to Offload iSCSI for SLES 11 SP4

To migrate from a software iSCSI installation to an offload iSCSI for SLES 11 SP4: 1. Update Open-iSCSI tools and iscsiuio to the latest available versions by

issuing the following commands: # rpm -ivh qlgc-open-iscsi-2.0_873.111.sles11sp4-3.x86_64.rpm --force # rpm -ivh iscsiuio-2.11.5.3-2.sles11sp4.x86_64.rpm --force

NOTE To retain the original contents of the inbox RPM during installation, you must use the -ivh option (instead of the -Uvh option), followed by the --force option.

6Boot from SAN Configuration iSCSI Boot from SAN

101 AH0054602-00 M

2. Edit the /etc/elilo.conf file, make the following changes, and then save the file:

Remove the ip=ibft parameter (if present) Add iscsi_firmware

3. Edit the /etc/sysconfig/kernel file as follows:

a. Locate the line that begins with INITRD_MODULES. This line will look similar to the following, but may contain different parameters: INITRD_MODULES="ata_piix ata_generic" or INITRD_MODULES="ahci"

b. Edit the line by adding qedi to the end of the existing line (inside the quotation marks). For example: INITRD_MODULES="ata_piix ata_generic qedi" or INITRD_MODULES="ahci qedi"

c. Save the file.

4. Edit the /etc/modprobe.d/unsupported-modules file, change the value for allow_unsupported_modules to 1, and then save the file: allow_unsupported_modules 1

5. Locate and delete the following files: /etc/init.d/boot.d/K01boot.open-iscsi /etc/init.d/boot.open-iscsi

6. Create a backup of initrd, and then build a new initrd by issuing the following commands.

# cd /boot/ # mkinitrd

7. Reboot the server, and then open the UEFI HII.

8. In the UEFI HII, disable iSCSI boot from BIOS, and then enable iSCSI HBA or boot for the adapter as follows:

a. Select the adapter port, and then select Device Level Configuration.

b. On the Device Level Configuration page, for the Virtualization Mode, select NPAR.

6Boot from SAN Configuration iSCSI Boot from SAN

102 AH0054602-00 M

c. Open the NIC Partitioning Configuration page and set the iSCSI Offload Mode to Enabled. (iSCSI HBA support is on partition 3 for a two--port adapter and on partition 2 for a four-port adapter.)

d. Open the NIC Configuration menu and set the Boot Protocol to UEFI iSCSI.

e. Open the iSCSI Configuration page and configure iSCSI settings.

9. Save the configuration and reboot the server.

The OS can now boot through the offload interface.

Migrating to Offload iSCSI for SLES 12 SP1/SP2

To migrate from a software iSCSI installation to an offload iSCSI for SLES 12 SP1/SP2: 1. Boot into the iSCSI non-offload/L2 boot from SAN operating system. Issue

the following commands to install the Open-iSCSI and iscsiuio RPMs: # rpm -ivh qlgc-open-iscsi-2.0_873.111.sles12p2-3.x86_64.rpm --force # rpm -ivh iscsiuio-2.11.5.3-2.sles12sp2.x86_64.rpm --force

2. Reload all the daemon services by issuing the following command: # systemctl daemon-reload

3. Enable iscsid and iscsiuio services (if they are not already enabled) by issuing the following commands: # systemctl enable iscsid # systemctl enable iscsiuio

4. Issue the following command: cat /proc/cmdline

5. Check if the OS has preserved any boot options, such as ip=ibft or rd.iscsi.ibft.

If there are preserved boot options, continue with Step 6.

If there are no preserved boot options, skip to Step 6 c.

NOTE To retain the original contents of the inbox RPM during installation, you must use the -ivh option (instead of the -Uvh option), followed by the --force option.

6Boot from SAN Configuration iSCSI Boot from SAN

103 AH0054602-00 M

6. Edit the /etc/default/grub file and modify the GRUB_CMDLINE_LINUX value:

a. Remove rd.iscsi.ibft (if present).

b. Remove any ip= boot options (if present).

c. Add rd.iscsi.firmware. For older distros, add iscsi_firmware.

7. Create a backup of the original grub.cfg file. The file is in the following locations:

Legacy boot: /boot/grub2/grub.cfg UEFI boot: /boot/efi/EFI/sles/grub.cfg for SLES

8. Create a new grub.cfg file by issuing the following command: # grub2-mkconfig -o

9. Compare the old grub.cfg file with the new grub.cfg file to verify your changes.

10. Replace the original grub.cfg file with the new grub.cfg file.

11. Build the initramfs file by issuing the following command: # dracut -f

12. Reboot the server, and then open the UEFI HII.

13. In the UEFI HII, disable iSCSI boot from BIOS, and then enable iSCSI HBA or boot for the adapter as follows:

a. Select the adapter port, and then select Device Level Configuration.

b. On the Device Level Configuration page, for the Virtualization Mode, select NPAR.

c. Open the NIC Partitioning Configuration page and set the iSCSI Offload Mode to Enabled. (iSCSI HBA support is on partition 3 for a two--port adapter and on partition 2 for a four-port adapter.)

d. Open the NIC Configuration menu and set the Boot Protocol to UEFI iSCSI.

e. Open the iSCSI Configuration page and configure iSCSI settings.

14. Save the configuration and reboot the server.

The OS can now boot through the offload interface.

6Boot from SAN Configuration iSCSI Boot from SAN

104 AH0054602-00 M

Linux Multipath Considerations iSCSI boot from SAN installations on Linux operating systems are currently supported only in a single-path configuration. To enable multipath configurations, perform the installation in a single path, using either an L2 or L4 path. After the server boots into the installed operating system, perform the required configurations for enabling multipath I/O (MPIO).

See the appropriate procedure in this section to migrate from L2 to L4 and configure MPIO for your OS:

Migrating and Configuring MPIO to Offloaded Interface for RHEL 6.9/6.10

Migrating and Configuring MPIO to Offloaded Interface for SLES 11 SP4

Migrating and Configuring MPIO to Offloaded Interface for SLES 12 SP1/SP2

Migrating and Configuring MPIO to Offloaded Interface for RHEL 6.9/6.10

To migrate from L2 to L4 and configure MPIO to boot the OS over an offloaded interface for RHEL 6.9/6.10: 1. Configure the iSCSI boot settings for L2 BFS on both ports of the adapter.

The boot will log in through only one port, but will create an iSCSI Boot Firmware Table (iBFT) interface for both ports.

2. While booting to the CD, ensure that you specify the following kernel parameters: ip=ibft linux dd

3. Provide the DUD and complete the installation.

4. Boot to the OS with L2.

5. Update Open-iSCSI tools and iscsiuio by issuing the following commands: # rpm -ivh qlgc-open-iscsi-2.0_873.111.rhel6u9-3.x86_64.rpm --force # rpm -ivh iscsiuio-2.11.5.5-6.rhel6u9.x86_64.rpm --force

6. Edit the /boot/efi/EFI/redhat/grub.conf file, make the following changes, and then save the file:

a. Remove ifname=eth5:14:02:ec:ce:dc:6d.

b. Remove ip=ibft.

c. Add selinux=0.

7. Build the initramfs file by issuing the following command: # dracut f

6Boot from SAN Configuration iSCSI Boot from SAN

105 AH0054602-00 M

8. Reboot and change the adapter boot settings to use L4 or iSCSI (HW) for both ports and to boot through L4.

9. After booting into the OS, set up the multipath daemon multipathd.conf: # mpathconf --enable --with_multipathd y # mpathconf enable

10. Start the multipathd service: # service multipathd start

11. Rebuild initramfs with multipath support. # dracut --force --add multipath --include /etc/multipath

12. Reboot the server and boot into OS with multipath.

1.

2.

Migrating and Configuring MPIO to Offloaded Interface for SLES 11 SP4

To migrate from L2 to L4 and configure MPIO to boot the OS over an offloaded interface for SLES 11 SP4: 1. Follow all the steps necessary to migrate a non-offload (L2) interface to an

offload (L4) interface, over a single path. See Migrating to Offload iSCSI for SLES 11 SP4.

2. After you boot into the OS using the L4 interface, prepare multipathing as follows:

a. Reboot the server and open the HII by going to System Setup/Utilities.

b. In the HII, select System Configuration, and select the second adapter port to be used for multipath.

c. On the Main Configuration Page under Port Level Configuration, set Boot Mode to iSCSI (HW) and enable iSCSI Offload.

d. On the Main Configuration Page under iSCSI Configuration, perform the necessary iSCSI configurations.

e. Reboot the server and boot into OS.

NOTE \

For any additional changes in the /etc/multipath.conf file to take effect, you must rebuild the initrd image and reboot the server.

6Boot from SAN Configuration iSCSI Boot from SAN

106 AH0054602-00 M

3. Set MPIO services to remain persistent on re-boot as follows: # chkconfig multipathd on # chkconfig boot.multipath on # chkconfig boot.udev on

4. Start multipath services as follows: # /etc/init.d/boot.multipath start # /etc/init.d/multipathd start

5. Run multipath v2 d to display multipath configuration with a dry run.

6. Locate the multipath.conf file under /etc/multipath.conf.

7. Edit the multipath.conf to enable the default section.

8. Rebuild initrd image to include MPIO support: # mkinitrd f multipath

9. Reboot the server and boot the OS with multipath support.

Migrating and Configuring MPIO to Offloaded Interface for SLES 12 SP1/SP2

To migrate from L2 to L4 and configure MPIO to boot the OS over an offloaded interface for SLES 12 SP1/SP2: 1. Configure the iSCSI boot settings for L2 BFS on both ports of the adapter.

The boot will log in through only one port, but will create an iSCSI Boot Firmware Table (iBFT) interface for both ports.

2. While booting to the CD, ensure that you specify the following kernel parameters: dud=1 rd.iscsi.ibft

3. Provide the DUD and complete the installation.

NOTE \

If the file is not present, copy multipath.conf from the /usr/share/doc/packages/multipath-tools folder: cp /usr/share/doc/packages/multipath-tools/multipath. conf.defaults /etc/multipath.conf

NOTE \

For any additional changes in the /etc/multipath.conf file to take effect, you must rebuild the initrd image and reboot the server.

6Boot from SAN Configuration iSCSI Boot from SAN

107 AH0054602-00 M

4. Boot to the OS with L2.

5. Update the Open-iSCSI tools by issuing the following commands: # rpm -ivh qlgc-open-iscsi-2.0_873.111.sles12sp1-3.x86_64.rpm --force # rpm -ivh iscsiuio-2.11.5.5-6.sles12sp1.x86_64.rpm --force

6. Edit the /etc/default/grub file by changing the rd.iscsi.ibft parameter to rd.iscsi.firmware, and then save the file.

7. Issue the following command: # grub2-mkconfig -o /boot/efi/EFI/suse/grub.cfg

8. To load the multipath module, issue the following command: # modprobe dm_multipath

9. To enable the multipath daemon, issue the following commands: # systemctl start multipathd.service # systemctl enable multipathd.service # systemctl start multipathd.socket

10. To run the multipath utility, issue the following commands: # multipath (may not show the multipath devices because it is booted with a single path on L2) # multipath -ll

11. To inject the multipath module in initrd, issue the following command: # dracut --force --add multipath --include /etc/multipath

12. Reboot the server and enter system settings by pressing the F9 key during the POST menu.

13. Change the UEFI configuration to use L4 iSCSI boot:

a. Open System Configuration, select the adapter port, and then select Port Level Configuration.

b. On the Port Level Configuration page, set the Boot Mode to iSCSI (HW) and set iSCSI Offload to Enabled.

c. Save the settings, and then exit the System Configuration Menu.

14. Reboot the system. The OS should now boot through the offload interface.

NOTE \

For any additional changes in the /etc/multipath.conf file to take effect, you must rebuild the initrd image and reboot the server.

6Boot from SAN Configuration iSCSI Boot from SAN

108 AH0054602-00 M

Configuring iSCSI Boot from SAN on VMware Because VMware does not natively support iSCSI boot from SAN offload, you must configure BFS through the software in preboot, and then transition to offload upon OS driver loads. For more information, see Enabling NPAR and the iSCSI HBA on page 71.

In VMware ESXi, iSCSI BFS configuration procedures include:

Setting the UEFI Main Configuration

Configuring the System BIOS for iSCSI Boot (L2)

Mapping the CD or DVD for OS Installation

Setting the UEFI Main Configuration To configure iSCSI boot from SAN on VMware: 1. Plug the 41xxx Series Adapter into a Dell 14G server. For example, plug a

PCIE and LOM (four ports or two ports) into an R740 server.

2. In the HII, go to System Setup, select Device Settings, and then select a an integrated NIC port to configure. Click Finish.

3. On the Main Configuration Page, select NIC Partitioning Configuration, and then click Finish.

4. On the Main Configuration Page, select Firmware Image Properties, view the non-configurable information, and then click Finish.

5. On the Main Configuration Page, select Device Level Configuration.

6. Complete the Device Level Configuration page (see Figure 6-19) as follows:

a. For Virtualization Mode, select either None, NPar, or NPar_EP for IBFT installation through the NIC interface.

b. For NParEP Mode, select Disabled.

c. For UEFI Driver Debug Level, select 10.

Figure 6-19. Integrated NIC: Device Level Configuration for VMware

6Boot from SAN Configuration iSCSI Boot from SAN

109 AH0054602-00 M

7. Go to the Main Configuration Page and select NIC Partitioning Configuration.

8. On the NIC Partitioning Configuration page, select Partition 1 Configuration.

9. Complete the Partition 1 Configuration page as follows:

a. For Link Speed, select either Auto Neg, 10Gbps, or 1Gbps.

b. Ensure that the link is up.

c. For Boot Protocol, select None.

d. For Virtual LAN Mode, select Disabled.

10. On the NIC Partitioning Configuration page, select Partition 2 Configuration.

11. Complete the Partition 2 Configuration page (see Figure 6-20) as follows:

a. For FCoE Mode, select Disabled.

b. For iSCSI Offload Mode, select Disabled.

Figure 6-20. Integrated NIC: Partition 2 Configuration for VMware

6Boot from SAN Configuration iSCSI Boot from SAN

110 AH0054602-00 M

Configuring the System BIOS for iSCSI Boot (L2) To configure the System BIOS on VMware: 1. On the System BIOS Settings page, select Boot Settings.

2. Complete the Boot Settings page as shown in Figure 6-21.

Figure 6-21. Integrated NIC: System BIOS, Boot Settings for VMware

3. On the System BIOS Settings page, select Network Settings.

4. On the Network Settings page under UEFI iSCSI Settings:

a. For iSCSI Device1, select Enabled.

b. Select UEFI Boot Settings.

5. On the iSCSI Device1 Settings page:

a. For Connection 1, select Enabled.

b. Select Connection 1 Settings.

6. On the Connection 1 Settings page (see Figure 6-22):

a. For Interface, select the adapter port on which to test the iSCSI boot firmware table (IBFT) boot from SAN.

b. For Protocol, select either IPv4 or IPv6.

c. For VLAN, select either Disabled (the default) or Enabled (if you want to test IBFT with a vLAN).

d. For DHCP, select Enabled (if the IP address is from the DHCP server) or Disabled (to use static IP configuration).

e. For Target info via DHCP, select Disabled.

6Boot from SAN Configuration iSCSI Boot from SAN

111 AH0054602-00 M

Figure 6-22. Integrated NIC: System BIOS, Connection 1 Settings for VMware

7. Complete the target details, and for Authentication Type, select either CHAP (to set CHAP details) or None (the default). Figure 6-23 shows an example.

Figure 6-23. Integrated NIC: System BIOS, Connection 1 Settings (Target) for VMware

6Boot from SAN Configuration iSCSI Boot from SAN

112 AH0054602-00 M

8. Save all configuration changes, and then reboot the server.

9. During system boot up, press the F11 key to start the Boot Manager.

10. In the Boot Manager under Boot Menu, Select UEFI Boot Option, select the Embedded SATA Port AHCI Controller.

Mapping the CD or DVD for OS Installation To map the CD or DVD: 1. Create a customized ISO image using the ESXi-Customizer and inject the

latest bundle or VIB.

2. Map the ISO to the server virtual consoles virtual media.

3. On the virtual optical drive, load the ISO file.

4. After the ISO is loaded successfully, press the F11 key.

5. On the Select a Disk To Install Or Upgrade window, under Storage Device, select the 3PARdata W disk, and then press the ENTER key. Figure 6-24 shows an example.

Figure 6-24. VMware iSCSI BFS: Selecting a Disk to Install

6. Start installation of the ESXi OS on the remote iSCSI LUN.

6Boot from SAN Configuration FCoE Boot from SAN

113 AH0054602-00 M

7. After the ESXi OS installation completes successfully, the system boots to the OS, as shown in Figure 6-25.

Figure 6-25. VMware iSCSI Boot from SAN Successful

FCoE Boot from SAN Marvell 41xxx Series Adapters support FCoE boot to enable network boot of operating systems to diskless systems. FCoE boot allows a Windows, Linux, or VMware operating system to boot from a Fibre Channel or FCoE target machine located remotely over an FCoE supporting network. You can set the FCoE option (offload path with Marvell offload FCoE driver) by opening the NIC Configuration menu and setting the Boot Protocol option to FCoE.

This section provides the following configuration information about FCoE boot from SAN:

FCoE Out-of-Box and Inbox Support

FCoE Preboot Configuration

Configuring FCoE Boot from SAN on Windows

Configuring FCoE Boot from SAN on Linux

Configuring FCoE Boot from SAN on VMware

6Boot from SAN Configuration FCoE Boot from SAN

114 AH0054602-00 M

FCoE Out-of-Box and Inbox Support Table 6-6 lists the operating systems inbox and out-of-box support for FCoE boot from SAN (BFS).

FCoE Preboot Configuration This section describes the installation and boot procedures for the Windows, Linux, and ESXi operating systems. To prepare the system BIOS, modify the system boot order and specify the BIOS boot protocol, if required.

Specifying the BIOS Boot Protocol FCoE boot from SAN is supported in UEFI mode only. Set the platform in boot mode (protocol) using the system BIOS configuration to UEFI.

Table 6-6. FCoE Out-of-Box and Inbox Boot from SAN Support

Out-of-Box Inbox

OS Version Hardware Offload FCoE BFS Support

Hardware Offload FCoE BFS Support

Windows 2012 Yes No

Windows 2012 R2 Yes No

Windows 2016 Yes No

Windows 2019 Yes Yes

RHEL 7.5 Yes Yes

RHEL 7.6 Yes Yes

RHEL 8.0 Yes Yes

SLES 15/15 SP1 Yes Yes

vSphere ESXi 6.5 U3 Yes No

vSphere ESXi 6.7 U2 Yes No

NOTE FCoE boot from SAN is supported on ESXi 5.5 and later. Not all adapter versions support FCoE and FCoE boot from SAN.

NOTE FCoE BFS is not supported in legacy BIOS mode.

6Boot from SAN Configuration FCoE Boot from SAN

115 AH0054602-00 M

Configuring Adapter UEFI Boot Mode To configure the boot mode to FCOE: 1. Restart the system.

2. Press the OEM hot key to enter System Setup (Figure 6-26). This is also known as UEFI HII.

Figure 6-26. System Setup: Selecting Device Settings

NOTE SAN boot is supported in the UEFI environment only. Make sure the system boot option is UEFI, and not legacy.

6Boot from SAN Configuration FCoE Boot from SAN

116 AH0054602-00 M

3. On the Device Settings page, select the Marvell FastLinQ adapter (Figure 6-27).

Figure 6-27. System Setup: Device Settings, Port Selection

6Boot from SAN Configuration FCoE Boot from SAN

117 AH0054602-00 M

4. On the Main Configuration Page, select NIC Configuration (Figure 6-28), and then press ENTER.

Figure 6-28. System Setup: NIC Configuration

5. On the NIC Configuration page, select Boot Mode, press ENTER, and then select FCoE as a preferred boot mode.

NOTE FCoE is not listed as a boot option if the FCoE Mode feature is disabled at the port level. If the Boot Mode preferred is FCoE, make sure the FCoE Mode feature is enabled as shown in Figure 6-29. Not all adapter versions support FCoE.

6Boot from SAN Configuration FCoE Boot from SAN

118 AH0054602-00 M

Figure 6-29. System Setup: FCoE Mode Enabled

To configure the FCoE boot parameters: 1. On the Device UEFI HII Main Configuration Page, select FCoE

Configuration, and then press ENTER.

2. On the FCoE Configuration Page, select FCoE General Parameters, and then press ENTER.

3. On the FCoE General Parameters page (Figure 6-30), press the UP ARROW and DOWN ARROW keys to select a parameter, and then press ENTER to select and input the following values:

Fabric Discovery Retry Count: Default value or as required

LUN Busy Retry Count: Default value or as required

6Boot from SAN Configuration FCoE Boot from SAN

119 AH0054602-00 M

Figure 6-30. System Setup: FCoE General Parameters

4. Return to the FCoE Configuration page.

5. Press ESC, and then select FCoE Target Parameters.

6. Press ENTER.

7. In the FCoE General Parameters Menu, enable Connect to the preferred FCoE target.

8. Type values for the following parameters (Figure 6-31) for the FCoE target, and then press ENTER:

World Wide Port Name Target n Boot LUN n

Where the value of n is between 1 and 8, enabling you to configure 8 FCoE targets.

6Boot from SAN Configuration FCoE Boot from SAN

120 AH0054602-00 M

Figure 6-31. System Setup: FCoE General Parameters

Configuring FCoE Boot from SAN on Windows FCoE boot from SAN information for Windows includes:

Windows Server 2012 R2 and 2016 FCoE Boot Installation

Configuring FCoE on Windows

FCoE Crash Dump on Windows

Injecting (Slipstreaming) Adapter Drivers into Windows Image Files

Windows Server 2012 R2 and 2016 FCoE Boot Installation For Windows Server 2012R2/2016 boot from SAN installation, Marvell requires the use of a slipstream DVD, or ISO image, with the latest Marvell drivers injected. See Injecting (Slipstreaming) Adapter Drivers into Windows Image Files on page 122.

The following procedure prepares the image for installation and booting in FCoE mode.

To set up Windows Server 2012R2/2016 FCoE boot: 1. Remove any local hard drives on the system to be booted (remote system).

2. Prepare the Windows OS installation media by following the slipstreaming steps in Injecting (Slipstreaming) Adapter Drivers into Windows Image Files on page 122.

6Boot from SAN Configuration FCoE Boot from SAN

121 AH0054602-00 M

3. Load the latest Marvell FCoE boot images into the adapter NVRAM.

4. Configure the FCoE target to allow a connection from the remote device. Ensure that the target has sufficient disk space to hold the new OS installation.

5. Configure the UEFI HII to set the FCoE boot type on the required adapter port, correct initiator, and target parameters for FCoE boot.

6. Save the settings and reboot the system. The remote system should connect to the FCoE target, and then boot from the DVD-ROM device.

7. Boot from DVD and begin installation.

8. Follow the on-screen instructions.

On the window that shows the list of disks available for the installation, the FCoE target disk should be visible. This target is a disk connected through the FCoE boot protocol, located in the remote FCoE target.

9. To proceed with Windows Server 2012R2/2016 installation, select Next, and then follow the on-screen instructions. The server will undergo a reboot multiple times as part of the installation process.

10. After the server boots to the OS, you should run the driver installer to complete the Marvell drivers and application installation.

Configuring FCoE on Windows By default, DCB is enabled on Marvell FastLinQ 41xxx FCoE- and DCB-compatible C-NICs. Marvell 41xxx FCoE requires a DCB-enabled interface. For Windows operating systems, use QConvergeConsole GUI or a command line utility to configure the DCB parameters.

FCoE Crash Dump on Windows Crash dump functionality is currently supported for FCoE boot for the FastLinQ 41xxx Series Adapters.

No additional configuration is required for FCoE crash-dump generation when in FCoE boot mode.

6Boot from SAN Configuration FCoE Boot from SAN

122 AH0054602-00 M

Injecting (Slipstreaming) Adapter Drivers into Windows Image Files To inject adapter drivers into the Windows image files: 1. Obtain the latest driver package for the applicable Windows Server version

(2012, 2012 R2, 2016, or 2019).

2. Extract the driver package to a working directory:

a. Open a command line session and navigate to the folder that contains the driver package.

b. To extract the driver Dell Update Package (DUP), issue the following command: start /wait NameOfDup.exe /s /drivers=

3. Download the Windows Assessment and Deployment Kit (ADK) version 10 from Microsoft:

https://developer.microsoft.com/en-us/windows/hardware/ windows-assessment-deployment-kit

4. Follow the Microsoft Add and Remove Drivers to an offline Windows Image article and inject the OOB driver extracted on Step 2, part b. See https://docs.microsoft.com/en-us/windows-hardware/manufacture/desktop/a dd-and-remove-drivers-to-an-offline-windows-image

Configuring FCoE Boot from SAN on Linux FCoE boot from SAN configuration for Linux covers the following:

Prerequisites for Linux FCoE Boot from SAN

Configuring Linux FCoE Boot from SAN

Prerequisites for Linux FCoE Boot from SAN The following are required for Linux FCoE boot from SAN to function correctly with the Marvell FastLinQ 41xxx 10/25GbE Controller.

General You no longer need to use the FCoE disk tabs in the Red Hat and SUSE installers because the FCoE interfaces are not exposed from the network interface and are automatically activated by the qedf driver.

SLES 12 and SLES 15 Driver update disk is recommended for SLES 12 SP 3 and later.

The installer parameter dud=1 is required to ensure that the installer will ask for the driver update disk.

6Boot from SAN Configuration FCoE Boot from SAN

123 AH0054602-00 M

Do not use the installer parameter withfcoe=1 because the software FCoE will conflict with the hardware offload if network interfaces from qede are exposed.

Configuring Linux FCoE Boot from SAN This section provides FCoE boot from SAN procedures for the following Linux distributions:

Configuring FCoE Boot from SAN for SLES 12 SP3 and Later

Using an FCoE Boot Device as a kdump Target

Configuring FCoE Boot from SAN for SLES 12 SP3 and Later No additional steps, other than injecting DUD for out-of-box driver, are necessary to perform boot from SAN installations when using SLES 12 SP3.

Using an FCoE Boot Device as a kdump Target When using a device exposed using the qedf driver as a kdump target for crash dumps, Marvell recommends that you specify the kdump crashkernel memory parameter at the kernel command line to be a minimum of 512MB. Otherwise, the kernel crash dump may not succeed.

For details on how to set the kdump crashkernel size, refer to your Linux distribution documentation.

Configuring FCoE Boot from SAN on VMware For VMware ESXi 6.5/6.7 boot from SAN installation, Marvell requires that you use a customized ESXi ISO image that is built with the latest Marvell Converged Network Adapter bundle injected. This section covers the following VMware FCoE boot from SAN procedures.

Injecting (Slipstreaming) ESXi Adapter Drivers into Image Files

Installing the Customized ESXi ISO

Injecting (Slipstreaming) ESXi Adapter Drivers into Image Files This procedure uses ESXi-Customizer tool v2.7.2 as an example, but you can use any ESXi customizer.

To inject adapter drivers into an ESXi image file: 1. Download ESXi-Customizer v2.7.2 or later.

2. Go to the ESXi customizer directory.

3. Issue the ESXi-Customizer.cmd command.

6Boot from SAN Configuration FCoE Boot from SAN

124 AH0054602-00 M

4. In the ESXi-Customizer dialog box, click Browse to complete the following.

a. Select the original VMware ESXi ISO file.

b. Select either the Marvell FCoE driver VIB file or the Marvell offline qedentv bundle ZIP file.

c. For the working directory, select the folder in which the customized ISO needs to be created.

d. Click Run.

Figure 6-32 shows an example.

Figure 6-32. ESXi-Customizer Dialog Box

5. Burn a DVD that contains the customized ISO build located in the working directory specified in Step 4c.

6. Use the new DVD to install the ESXi OS.

Installing the Customized ESXi ISO 1. Load the latest Marvell FCOE boot images into the adapter NVRAM.

2. Configure the FCOE target to allow a valid connection with the remote machine. Ensure that the target has sufficient free disk space to hold the new OS installation.

3. Configure the UEFI HII to set the FCOE boot type on the required adapter port, the correct initiator, and the target parameters for FCOE boot.

6Boot from SAN Configuration FCoE Boot from SAN

125 AH0054602-00 M

4. Save the settings and reboot the system.

The initiator should connect to an FCOE target and then boot the system from the DVD-ROM device.

5. Boot from the DVD and begin installation.

6. Follow the on-screen instructions.

On the window that shows the list of disks available for the installation, the FCOE target disk should be visible because the injected Converged Network Adapter bundle is inside the customized ESXi ISO. Figure 6-33 shows an example.

Figure 6-33. Select a VMware Disk to Install

7. Select the LUN on which ESXi can install, and then press ENTER.

8. On the next window, click Next, and then follow the on-screen instructions.

9. When installation completes, reboot the server and eject the DVD.

10. During the server boot, press the F9 key to access the One-Time Boot Menu, and then select Boot media to QLogic adapter port.

11. Under Boot Menu, select the newly installed ESXi to load through boot from SAN.

6Boot from SAN Configuration FCoE Boot from SAN

126 AH0054602-00 M

Figure 6-34 provides two examples.

Figure 6-34. VMware USB Boot Options

127 AH0054602-00 M

7 RoCE Configuration

This chapter describes RDMA over converged Ethernet (RoCE v1 and v2) configuration on the 41xxx Series Adapter, the Ethernet switch, and the Windows, Linux, or VMware host, including:

Supported Operating Systems and OFED

Planning for RoCE on page 128

Preparing the Adapter on page 129

Preparing the Ethernet Switch on page 129

Configuring RoCE on the Adapter for Windows Server on page 133

Configuring RoCE on the Adapter for Linux on page 150

Configuring RoCE on the Adapter for VMware ESX on page 164

Configuring DCQCN on page 171

Supported Operating Systems and OFED Table 7-1 shows the operating system support for RoCE v1, RoCE v2, iWARP, and OpenFabrics Enterprise Distribution (OFED). OFED is not supported on Windows or VMware ESXi.

NOTE Some RoCE features may not be fully enabled in the current release.

Table 7-1. OS Support for RoCE v1, RoCE v2, iWARP, iSER, and OFED

Operating System Inbox OFED-4.17-1 GA

Windows Server 2012 N/A N/A

Windows Server 2012 R2 No N/A

Windows Server 2016 No N/A

Windows Server 2019 RoCE v1, RoCE v2, iWARP N/A

RHEL 7.6 RoCE v1, RoCE v2, iWARP, iSER RoCE v1, RoCE v2, iWARP

7RoCE Configuration Planning for RoCE

128 AH0054602-00 M

Planning for RoCE As you prepare to implement RoCE, consider the following limitations:

If you are using the inbox OFED, the operating system should be the same on the server and client systems. Some of the applications may work between different operating systems, but there is no guarantee. This is an OFED limitation.

For OFED applications (most often perftest applications), server and client applications should use the same options and values. Problems can arise if the operating system and the perftest application have different versions. To confirm the perftest version, issue the following command: # ib_send_bw --version

Building libqedr in inbox OFED requires installing libibverbs-devel.

Running user space applications in inbox OFED requires installing the InfiniBand Support group, by yum groupinstall InfiniBand Support that contains libibcm, libibverbs, and more.

OFED and RDMA applications that depend on libibverbs also require the Marvell RDMA user space library, libqedr. Install libqedr using the libqedr RPM or source packages.

RoCE supports only little endian.

RHEL 7.7 RoCE v1, RoCE v2, iWARP, iSER No

RHEL 8.0 RoCE v1, RoCE v2, iWARP, iSER No

RHEL 8.1 RoCE v1, RoCE v2, iWARP, iSER No

SLES 12 SP4 RoCE v1, RoCE v2, iWARP, iSER RoCE v1, RoCE v2, iWARP

SLES 15 SP0 RoCE v1, RoCE v2, iWARP, iSER RoCE v1, RoCE v2, iWARP

SLES 15 SP1 RoCE v1, RoCE v2, iWARP, iSER No

CentOS 7.6 RoCE v1, RoCE v2, iWARP, iSER RoCE v1, RoCE v2, iWARP

VMware ESXi 6.5 U3 RoCE v1, RoCE v2 N/A

VMware ESXi 6.7 U2 RoCE v1, RoCE v2 N/A

Table 7-1. OS Support for RoCE v1, RoCE v2, iWARP, iSER, and OFED (Continued)

Operating System Inbox OFED-4.17-1 GA

7RoCE Configuration Preparing the Adapter

129 AH0054602-00 M

Preparing the Adapter Follow these steps to enable DCBX and specify the RoCE priority using the HII management application. For information about the HII application, see Chapter 5 Adapter Preboot Configuration.

To prepare the adapter: 1. On the Main Configuration Page, select Data Center Bridging (DCB)

Settings, and then click Finish.

2. In the Data Center Bridging (DCB) Settings window, click the DCBX Protocol option. The 41xxx Series Adapter supports both CEE and IEEE protocols. This value should match the corresponding value on the DCB switch. In this example, select CEE or Dynamic.

3. In the RoCE Priority box, type a priority value. This value should match the corresponding value on the DCB switch. In this example, type 5. Typically, 0 is used for the default lossy traffic class, 3 is used for the FCoE traffic class, and 4 is used for lossless iSCSI-TLV over DCB traffic class.

4. Click Back.

5. When prompted, click Yes to save the changes. Changes will take effect after a system reset.

For Windows, you can configure DCBX using the HII or QoS method. The configuration shown in this section is through HII. For QoS, refer to Configuring QoS for RoCE on page 259.

Preparing the Ethernet Switch This section describes how to configure a Cisco Nexus 6000 Ethernet Switch and a Dell Z9100 Ethernet Switch for RoCE.

Configuring the Cisco Nexus 6000 Ethernet Switch

Configuring the Dell Z9100 Ethernet Switch for RoCE

Configuring the Cisco Nexus 6000 Ethernet Switch Steps for configuring the Cisco Nexus 6000 Ethernet Switch for RoCE include configuring class maps, configuring policy maps, applying the policy, and assigning a vLAN ID to the switch port.

To configure the Cisco switch: 1. Open a config terminal session as follows:

Switch# config terminal switch(config)#

7RoCE Configuration Preparing the Ethernet Switch

130 AH0054602-00 M

2. Configure the quality of service (QoS) class map and set the RoCE priority (cos) to match the adapter (5) as follows: switch(config)# class-map type qos class-roce switch(config)# match cos 5

3. Configure queuing class maps as follows: switch(config)# class-map type queuing class-roce switch(config)# match qos-group 3

4. Configure network QoS class maps as follows: switch(config)# class-map type network-qos class-roce switch(config)# match qos-group 3

5. Configure QoS policy maps as follows: switch(config)# policy-map type qos roce switch(config)# class type qos class-roce switch(config)# set qos-group 3

6. Configure queuing policy maps to assign network bandwidth. In this example, use a value of 50 percent: switch(config)# policy-map type queuing roce switch(config)# class type queuing class-roce switch(config)# bandwidth percent 50

7. Configure network QoS policy maps to set priority flow control for no-drop traffic class as follows: switch(config)# policy-map type network-qos roce switch(config)# class type network-qos class-roce switch(config)# pause no-drop

8. Apply the new policy at the system level as follows: switch(config)# system qos switch(config)# service-policy type qos input roce switch(config)# service-policy type queuing output roce switch(config)# service-policy type queuing input roce switch(config)# service-policy type network-qos roce

9. Assign a vLAN ID to the switch port to match the vLAN ID assigned to the adapter (5). switch(config)# interface ethernet x/x switch(config)# switchport mode trunk switch(config)# switchport trunk allowed vlan 1,5

7RoCE Configuration Preparing the Ethernet Switch

131 AH0054602-00 M

Configuring the Dell Z9100 Ethernet Switch for RoCE Configuring the Dell Z9100 Ethernet Switch for RoCE comprises configuring a DCB map for RoCE, configuring priority-based flow control (PFC) and enhanced transmission selection (ETS), verifying the DCB map, applying the DCB map to the port, verifying PFC and ETS on the port, specifying the DCB protocol, and assigning a VLAN ID to the switch port.

To configure the Dell switch: 1. Create a DCB map.

Dell# configure Dell(conf)# dcb-map roce Dell(conf-dcbmap-roce)#

2. Configure two ETS traffic classes in the DCB map with 50 percent bandwidth assigned for RoCE (group 1). Dell(conf-dcbmap-roce)# priority-group 0 bandwidth 50 pfc off Dell(conf-dcbmap-roce)# priority-group 1 bandwidth 50 pfc on

3. Configure the PFC priority to match the adapter traffic class priority number (5). Dell(conf-dcbmap-roce)# priority-pgid 0 0 0 0 0 1 0 0

4. Verify the DCB map configuration priority group. Dell(conf-dcbmap-roce)# do show qos dcb-map roce ----------------------- State :Complete PfcMode :ON -------------------- PG:0 TSA:ETS BW:40 PFC:OFF Priorities:0 1 2 3 4 6 7

PG:1 TSA:ETS BW:60 PFC:ON Priorities:5

NOTE For instructions on configuring a Dell Z91000 switch port to connect to the 41xxx Series Adapter at 25Gbps, see Dell Z9100 Switch Configuration on page 298.

7RoCE Configuration Preparing the Ethernet Switch

132 AH0054602-00 M

5. Apply the DCB map to the port. Dell(conf)# interface twentyFiveGigE 1/8/1 Dell(conf-if-tf-1/8/1)# dcb-map roce

6. Verify the ETS and PFC configuration on the port. The following examples show summarized interface information for ETS and detailed interface information for PFC.

Dell(conf-if-tf-1/8/1)# do show interfaces twentyFiveGigE 1/8/1 ets summary Interface twentyFiveGigE 1/8/1 Max Supported TC is 4 Number of Traffic Classes is 8 Admin mode is on

Admin Parameters : ------------------ Admin is enabled

PG-grp Priority# BW-% BW-COMMITTED BW-PEAK TSA % Rate(Mbps) Burst(KB) Rate(Mbps) Burst(KB) ------------------------------------------------------------------------ 0 0,1,2,3,4,6,7 40 - - - - ETS 1 5 60 - - - - ETS 2 - - - - - - 3 - - - - - -

Dell(Conf)# do show interfaces twentyFiveGigE 1/8/1 pfc detail Interface twentyFiveGigE 1/8/1 Admin mode is on Admin is enabled, Priority list is 5 Remote is enabled, Priority list is 5 Remote Willing Status is enabled Local is enabled, Priority list is 5 Oper status is init PFC DCBX Oper status is Up State Machine Type is Feature TLV Tx Status is enabled PFC Link Delay 65535 pause quntams Application Priority TLV Parameters : -------------------------------------- FCOE TLV Tx Status is disabled

7RoCE Configuration Configuring RoCE on the Adapter for Windows Server

133 AH0054602-00 M

ISCSI TLV Tx Status is enabled Local FCOE PriorityMap is 0x0 Local ISCSI PriorityMap is 0x20 Remote ISCSI PriorityMap is 0x200

66 Input TLV pkts, 99 Output TLV pkts, 0 Error pkts, 0 Pause Tx pkts, 0 Pause Rx pkts 66 Input Appln Priority TLV pkts, 99 Output Appln Priority TLV pkts, 0 Error Appln Priority TLV Pkts

7. Configure the DCBX protocol (CEE in this example). Dell(conf)# interface twentyFiveGigE 1/8/1 Dell(conf-if-tf-1/8/1)# protocol lldp Dell(conf-if-tf-1/8/1-lldp)# dcbx version cee

8. Assign a VLAN ID to the switch port to match the VLAN ID assigned to the adapter (5). Dell(conf)# interface vlan 5 Dell(conf-if-vl-5)# tagged twentyFiveGigE 1/8/1

Configuring RoCE on the Adapter for Windows Server

Configuring RoCE on the adapter for Windows Server host comprises enabling RoCE on the adapter and verifying the Network Direct MTU size.

To configure RoCE on a Windows Server host: 1. Enable RoCE on the adapter.

a. Open the Windows Device Manager, and then open the 41xxx Series Adapters NDIS Miniport Properties.

b. On the QLogic FastLinQ Adapter Properties, click the Advanced tab.

c. On the Advanced page, configure the properties listed in Table 7-2 by selecting each item under Property and choosing an appropriate Value for that item. Then click OK.

NOTE The VLAN ID need not be the same as the RoCE traffic class priority number. However, using the same number makes configurations easier to understand.

7RoCE Configuration Configuring RoCE on the Adapter for Windows Server

134 AH0054602-00 M

Figure 7-1 shows an example of configuring a property value.

Figure 7-1. Configuring RoCE Properties

Table 7-2. Advanced Properties for RoCE

Property Value or Description

NetworkDirect Functionality

Enabled

Network Direct Mtu Size

The network direct MTU size must be less than the jumbo packet size.

Quality of Service For RoCE v1/v2, always select Enabled to allow Win- dows DCB-QoS service to control and monitor DCB. For more information, see Configuring QoS by Disabling DCBX on the Adapter on page 260 and Configuring QoS by Enabling DCBX on the Adapter on page 264.

NetworkDirect Technology

RoCE or RoCE v2.

VLAN ID Assign any vLAN ID to the interface. The value must be the same as is assigned on the switch.

7RoCE Configuration Configuring RoCE on the Adapter for Windows Server

135 AH0054602-00 M

2. Using Windows PowerShell, verify that RDMA is enabled on the adapter. The Get-NetAdapterRdma command lists the adapters that support RDMAboth ports are enabled.

PS C:\Users\Administrator> Get-NetAdapterRdma Name InterfaceDescription Enabled ----- -------------------- ------- SLOT 4 3 Port 1 QLogic FastLinQ QL41262... True SLOT 4 3 Port 2 QLogic FastLinQ QL41262... True

3. Using Windows PowerShell, verify that NetworkDirect is enabled on the host operating system. The Get-NetOffloadGlobalSetting command shows NetworkDirect is enabled. PS C:\Users\Administrators> Get-NetOffloadGlobalSetting ReceiveSideScaling : Enabled ReceiveSegmentCoalescing : Enabled Chimney : Disabled TaskOffload : Enabled NetworkDirect : Enabled NetworkDirectAcrossIPSubnets : Blocked PacketCoalescingFilter : Disabled

4. Connect a server message block (SMB) drive, run RoCE traffic, and verify the results.

To set up and connect to an SMB drive, view the information available online from Microsoft:

https://technet.microsoft.com/en-us/library/hh831795(v=ws.11).aspx

5. By default, Microsoft's SMB Direct establishes two RDMA connections per port, which provides good performance, including line rate at a higher block size (for example, 64KB). To optimize performance, you can change the quantity of RDMA connections per RDMA interface to four (or greater).

To increase the quantity of RDMA connections to four (or more), issue the following command in Windows PowerShell: PS C:\Users\Administrator> Set-ItemProperty -Path "HKLM:\SYSTEM\CurrentControlSet\Services\LanmanWorkstation\ Parameters" ConnectionCountPerRdmaNetworkInterface -Type DWORD -Value 4 Force

NOTE If you are configuring RoCE over Hyper-V, do not assign a vLAN ID to the physical interface.

7RoCE Configuration Configuring RoCE on the Adapter for Windows Server

136 AH0054602-00 M

Viewing RDMA Counters The following procedure also applies to iWARP.

To view RDMA counters for RoCE: 1. Launch Performance Monitor.

2. Open the Add Counters dialog box. Figure 7-2 shows an example.

Figure 7-2. Add Counters Dialog Box

7RoCE Configuration Configuring RoCE on the Adapter for Windows Server

137 AH0054602-00 M

3. Select one of the following counter types:

Cavium FastLinQ Congestion Control: Increment when there is congestion in the network and ECN is

enabled on the switch.

Describe RoCE v2 ECN Marked Packets and Congestion Notification Packets (CNPs) sent and received successfully.

Apply only to RoCE v2.

Cavium FastLinQ Port Counters:

Increment when there is congestion in the network.

Pause counters increment when flow control or global pause is configured and there is a congestion in the network.

PFC counters increment when priority flow control is configured and there is a congestion in the network.

Cavium FastLinQ RDMA Error Counters:

Increment if any error occurs in transport operations.

For details, see Table 7-3.

4. Under Instances of selected object, select Total, and then click Add.

NOTE If Marvell RDMA counters are not listed in the Performance Monitor Add Counters dialog box, manually add them by issuing the following command from the driver location: Lodctr /M:qend.man

7RoCE Configuration Configuring RoCE on the Adapter for Windows Server

138 AH0054602-00 M

Figure 7-3 shows three examples of the counter monitoring output.

Figure 7-3. Performance Monitor: 41xxx Series Adapters Counters

Table 7-3 provides details about error counters.

Table 7-3. Marvell FastLinQ RDMA Error Counters

RDMA Error Counter Description

Applies to

RoCE?

Applies to

iWARP? Troubleshooting

CQ overflow

A completion queue on which an RDMA work request is posted. This counter specifies the quantity of instances where there was a com- pletion for a work request on the send or receive queue, but no space on the associated completion queue.

Yes Yes Indicates a software design issue causing an insufficient comple- tion queue size.

Requestor Bad response

A malformed response was returned by the responder.

Yes Yes

7RoCE Configuration Configuring RoCE on the Adapter for Windows Server

139 AH0054602-00 M

Requestor CQEs flushed with error

Posted work requests may be flushed by sending completions with a flush status to the CQ (without completing the actual execution of the work request) if the QP moves to an error state for any reason and pending work requests exist. If a work request completed with error status, all other pending work requests for that QP are flushed.

Yes Yes Occurs when the RDMA connection is down.

Requestor Local length

The RDMA Read response message contained too much or too little pay- load data.

Yes Yes Usually indicates an issue with the host soft- ware components.

Requestor local protection

The locally posted work requests data segment does not reference a memory region that is valid for the requested operation.

Yes Yes Usually indicates an issue with the host soft- ware components.

Requestor local QP operation

An internal QP consistency error was detected while processing this work request.

Yes Yes

Requestor Remote access

A protection error occurred on a remote data buffer to be read by an RDMA Read, written by an RDMA Write, or accessed by an atomic operation.

Yes Yes

Requestor Remote Invalid request

The remote side received an invalid message on the channel. The invalid request may have been a Send mes- sage or an RDMA request.

Yes Yes Possible causes include the operation is not supported by this receive queue, insuffi- cient buffering to receive a new RDMA or atomic operation request, or the length specified in an RDMA request is greater than 231 bytes.

Table 7-3. Marvell FastLinQ RDMA Error Counters (Continued)

RDMA Error Counter Description

Applies to

RoCE?

Applies to

iWARP? Troubleshooting

7RoCE Configuration Configuring RoCE on the Adapter for Windows Server

140 AH0054602-00 M

Requestor remote operation

Remote side could not complete the operation requested due to a local issue.

Yes Yes A software issue at the remote side (for exam- ple, one that caused a QP error or a mal- formed WQE on the RQ) prevented opera- tion completion.

Requestor retry exceeded

Transport retries have exceeded the maximum limit.

Yes Yes The remote peer may have stopped respond- ing, or a network issue is preventing messages acknowledgment.

Requestor RNR Retries exceeded

Retry due to RNR NAK received have been tried the maximum num- ber of times without success.

Yes No The remote peer may have stopped respond- ing, or a network issue is preventing messages acknowledgment.

Responder CQE flushed

Posted work requests (receive buf- fers on RQ) may be flushed by send- ing completions with a flush status to the CQ if the QP moves to an error state for any reason, and pending receive buffers exist on the RQ. If a work request completed with an error status, all other pending work requests for that QP are flushed.

Yes Yes

Responder local length

Invalid length in inbound messages. Yes Yes Misbehaving remote peer. For example, the inbound send mes- sages have lengths greater than the receive buffer size.

Responder local protection

The locally posted work requests data segment does not reference a memory region that is valid for the requested operation.

Yes Yes Indicates a software issue with memory management.

Table 7-3. Marvell FastLinQ RDMA Error Counters (Continued)

RDMA Error Counter Description

Applies to

RoCE?

Applies to

iWARP? Troubleshooting

7RoCE Configuration Configuring RoCE on the Adapter for Windows Server

141 AH0054602-00 M

Configuring RoCE for SR-IOV VF Devices (VF RDMA) The following sections describe how to configure RoCE for SR-IOV VF devices (also referred to as VF RDMA). Associated information and limitations are also provided.

Configuration Instructions To configure VF RDMA: 1. Install the VF RDMA capable components (drivers, firmware, multiboot

image (MBI)).

2. Configure QoS for VF RDMA.

QoS configuration is needed to configure priority flow control (PFC) for RDMA. Configure QoS in the host as documented in Configuring QoS for RoCE on page 259. (QoS configuration must be done in the host, not in the VM).

3. Configure Windows Hyper-V for VF RDMA:

a. Enable SR-IOV in HII and on the Advanced tab in Windows Device Manager.

b. Open the Windows Hyper-V Manager on the host.

Responder Local QP Operation error

An internal QP consistency error was detected while processing this work request.

Yes Yes Indicates a software issue.

Responder remote invalid request

The responder detected an invalid inbound message on the channel.

Yes Yes Indicates possible mis- behavior by a remote peer. Possible causes include: the operation is not supported by this receive queue, insuffi- cient buffering to receive a new RDMA request, or the length specified in an RDMA request is greater than 231 bytes.

Table 7-3. Marvell FastLinQ RDMA Error Counters (Continued)

RDMA Error Counter Description

Applies to

RoCE?

Applies to

iWARP? Troubleshooting

7RoCE Configuration Configuring RoCE on the Adapter for Windows Server

142 AH0054602-00 M

c. Open the Virtual Switch Manager from the right pane.

d. Select New Virtual Network switch with type External. Figure 7-4 shows an example.

Figure 7-4. Setting an External New Virtual Network Switch

7RoCE Configuration Configuring RoCE on the Adapter for Windows Server

143 AH0054602-00 M

e. Click the External network button, and then select the appropriate adapter. Click Enable single-root I/O virtualization (SR-IOV). Figure 7-5 shows an example.

Figure 7-5. Setting SR-IOV for New Virtual Switch

7RoCE Configuration Configuring RoCE on the Adapter for Windows Server

144 AH0054602-00 M

f. Create a VM and open the VM settings.

Figure 7-6 shows an example.

Figure 7-6. VM Settings

g. Select Add Hardware, and then select Network Adapter to assign the virtual network adapters (VMNICs) to the VM.

h. Select the newly created virtual switch.

7RoCE Configuration Configuring RoCE on the Adapter for Windows Server

145 AH0054602-00 M

i. Enable VLAN to the network adapter.

Figure 7-7 shows an example.

Figure 7-7. Enabling VLAN to the Network Adapter

7RoCE Configuration Configuring RoCE on the Adapter for Windows Server

146 AH0054602-00 M

j. Expand the network adapter settings. Under Single-root I/O virtualization, select Enable SR-IOV to enable SR-IOV capabilities for the VMNIC.

Figure 7-8 shows an example.

Figure 7-8. Enabling SR-IOV for the Network Adapter

4. Issue the following PowerShell command on the host to enable RDMA capabilities for the VMNIC (SR-IOV VF). Set-VMNetworkAdapterRdma -VMName -VMNetworkAdapterName -RdmaWeight 100

NOTE The VM must be powered off before issuing the PowerShell command.

7RoCE Configuration Configuring RoCE on the Adapter for Windows Server

147 AH0054602-00 M

5. Upgrade the Marvell drivers in the VM by booting the VM and installing the latest drivers using the Windows Super Installer on the Marvell CD.

Figure 7-9 shows an example.

Figure 7-9. Upgrading Drivers in VM

7RoCE Configuration Configuring RoCE on the Adapter for Windows Server

148 AH0054602-00 M

6. Enable RMDA on the Microsoft network device associated with the VF inside the VM.

Figure 7-10 shows an example.

Figure 7-10. Enabling RDMA on the VMNIC

7. Start the VM RMDA traffic:

a. Connect a server message block (SMB) drive, run RoCE traffic, and verify the results.

b. Open the Performance monitor in the VM, and then add RDMA Activity counter.

7RoCE Configuration Configuring RoCE on the Adapter for Windows Server

149 AH0054602-00 M

c. Verify that RDMA traffic is running.

Figure 7-11 provides an example.

Figure 7-11. RDMA Traffic

Limitations VF RDMA has the following limitations:

VF RDMA is supported only for 41xxx-based devices.

At the time of publication, only RoCEv2 is supported for VF RDMA. The same network direct technology must be configured in physical functions on both the host and SR-IOV VFs in the VM.

A maximum of 16 VFs per PF can support VF RDMA. For quad-port adapters, the maximum is 8 VFs per PF.

VF RDMA is supported only in Windows Server 2019 (for both the host and VM OSs).

VF RDMA is not supported for Linux VMs on Windows Hypervisor.

VF RDMA is not supported in NPAR mode.

A maximum of 128 queue pairs (QPs)/connections are supported per VF.

RDMA traffic between PF and its VFs, and among VFs of same PF, is supported. This traffic pattern is referred to as loopback traffic.

7RoCE Configuration Configuring RoCE on the Adapter for Linux

150 AH0054602-00 M

On some older server platforms, VF devices may not be enumerated for one of the NIC PCI functions (PF). This limitation is because of the increased PCI base address register (BAR) requirements to support VF RDMA, meaning that the OS/BIOS cannot assign the required BAR for each VF.

To support the maximum number of QPs in a VM, approximately 8GB of RAM must be available, assuming that only one VF is assigned to the VM. If less than 8GB of RAM is assigned to VM, there can be a sudden drop in the number of active connections due to insufficient memory and memory allocation failures.

Configuring RoCE on the Adapter for Linux This section describes the RoCE configuration procedure for RHEL and SLES. It also describes how to verify the RoCE configuration and provides some guidance about using group IDs (GIDs) with vLAN interfaces.

RoCE Configuration for RHEL

RoCE Configuration for SLES

Verifying the RoCE Configuration on Linux

vLAN Interfaces and GID Index Values

RoCE v2 Configuration for Linux

Configuring RoCE for SR-IOV VF Devices (VF RDMA)

RoCE Configuration for RHEL To configure RoCE on the adapter, the Open Fabrics Enterprise Distribution (OFED) must be installed and configured on the RHEL host.

To prepare inbox OFED for RHEL: 1. While installing or upgrading the operating system, select the InfiniBand and

OFED support packages.

2. Install the following RPMs from the RHEL ISO image: libibverbs-devel-x.x.x.x86_64.rpm (required for libqedr library) perftest-x.x.x.x86_64.rpm (required for InfiniBand bandwidth and latency applications)

or, using Yum, install the inbox OFED: yum groupinstall "Infiniband Support" yum install perftest yum install tcl tcl-devel tk zlib-devel libibverbs libibverbs-devel

7RoCE Configuration Configuring RoCE on the Adapter for Linux

151 AH0054602-00 M

3. Install the new Linux drivers as described in Installing the Linux Drivers with RDMA on page 14.

RoCE Configuration for SLES To configure RoCE on the adapter for a SLES host, OFED must be installed and configured on the SLES host.

To install inbox OFED for SLES: 1. While installing or upgrading the operating system, select the InfiniBand

support packages.

2. (SLES 12.x) Install the following RPMs from the corresponding SLES SDK kit image. libibverbs-devel-x.x.x.x86_64.rpm (required for libqedr installation) perftest-x.x.x.x86_64.rpm (required for bandwidth and latency applications)

3. (SLES 15/15 SP1) Install the following RPMs.

After installation, the rdma-core*, libibverbs*, libibumad*, libibmad*, librdmacm*, and perftest RPMs may be missing (all are required for RDMA). Install these packages using one of the following methods:

Load the Package DVD and install the missing RPMs.

Use the zypper command to install the missing RPMs. For example: #zypper install rdma* #zypper install libib* #zypper install librdma* #zypper install perftest

4. Install the Linux drivers, as described in Installing the Linux Drivers with RDMA on page 14.

NOTE During installation, if you already selected the previously mentioned packages, you need not reinstall them. The inbox OFED and support packages may vary depending on the operating system version.

7RoCE Configuration Configuring RoCE on the Adapter for Linux

152 AH0054602-00 M

Verifying the RoCE Configuration on Linux After installing OFED, installing the Linux driver, and loading the RoCE drivers, verify that the RoCE devices were detected on all Linux operating systems.

To verify RoCE configuration on Linux: 1. Stop firewall tables using service/systemctl commands.

2. For RHEL only: If the RDMA service is installed (yum install rdma), verify that the RDMA service has started.

On RHEL or CentOS: Use the service rdma status command to start service:

If RDMA has not started, issue the following command: # service rdma start

If RDMA does not start, issue either of the following alternative commands: # /etc/init.d/rdma start or # systemctl start rdma.service

3. Verify that the RoCE devices were detected by examining the dmesg logs: # dmesg|grep qedr [87910.988411] qedr: discovered and registered 2 RoCE funcs

4. Verify that all of the modules have been loaded. For example: # lsmod|grep qedr qedr 89871 0 qede 96670 1 qedr qed 2075255 2 qede,qedr ib_core 88311 16 qedr, rdma_cm, ib_cm, ib_sa,iw_cm,xprtrdma,ib_mad,ib_srp, ib_ucm,ib_iser,ib_srpt,ib_umad, ib_uverbs,rdma_ucm,ib_ipoib,ib_isert

NOTE For RHEL 7.x and SLES 12 SPx and later, RDMA service starts itself after reboot.

7RoCE Configuration Configuring RoCE on the Adapter for Linux

153 AH0054602-00 M

5. Configure the IP address and enable the port using a configuration method such as ifconfig. For example: # ifconfig ethX 192.168.10.10/24 up

6. Issue the ibv_devinfo command. For each PCI function, you should see a separate hca_id, as shown in the following example: root@captain:~# ibv_devinfo hca_id: qedr0 transport: InfiniBand (0) fw_ver: 8.3.9.0 node_guid: 020e:1eff:fe50:c7c0 sys_image_guid: 020e:1eff:fe50:c7c0 vendor_id: 0x1077 vendor_part_id: 5684 hw_ver: 0x0 phys_port_cnt: 1 port: 1 state: PORT_ACTIVE (1) max_mtu: 4096 (5) active_mtu: 1024 (3) sm_lid: 0 port_lid: 0 port_lmc: 0x00 link_layer: Ethernet

7. Verify the L2 and RoCE connectivity between all servers: one server acts as a server, another acts as a client.

Verify the L2 connection using a simple ping command.

Verify the RoCE connection by performing an RDMA ping on the server or client:

On the server, issue the following command: ibv_rc_pingpong -d -g 0 On the client, issue the following command: ibv_rc_pingpong -d -g 0

7RoCE Configuration Configuring RoCE on the Adapter for Linux

154 AH0054602-00 M

The following are examples of successful ping pong tests on the server and the client.

Server Ping: root@captain:~# ibv_rc_pingpong -d qedr0 -g 0 local address: LID 0x0000, QPN 0xff0000, PSN 0xb3e07e, GID fe80::20e:1eff:fe50:c7c0 remote address: LID 0x0000, QPN 0xff0000, PSN 0x934d28, GID fe80::20e:1eff:fe50:c570 8192000 bytes in 0.05 seconds = 1436.97 Mbit/sec 1000 iters in 0.05 seconds = 45.61 usec/iter Client Ping: root@lambodar:~# ibv_rc_pingpong -d qedr0 -g 0 192.168.10.165 local address: LID 0x0000, QPN 0xff0000, PSN 0x934d28, GID fe80::20e:1eff:fe50:c570 remote address: LID 0x0000, QPN 0xff0000, PSN 0xb3e07e, GID fe80::20e:1eff:fe50:c7c0 8192000 bytes in 0.02 seconds = 4211.28 Mbit/sec 1000 iters in 0.02 seconds = 15.56 usec/iter To display RoCE statistics, issue the following commands, where X is the

device number: > mount -t debugfs nodev /sys/kernel/debug > cat /sys/kernel/debug/qedr/qedrX/stats

vLAN Interfaces and GID Index Values If you are using vLAN interfaces on both the server and the client, you must also configure the same vLAN ID on the switch. If you are running traffic through a switch, the InfiniBand applications must use the correct GID value, which is based on the vLAN ID and vLAN IP address.

Based on the following results, the GID value (-x 4 / -x 5) should be used for any perftest applications.

# ibv_devinfo -d qedr0 -v|grep GID GID[ 0]: fe80:0000:0000:0000:020e:1eff:fe50:c5b0 GID[ 1]: 0000:0000:0000:0000:0000:ffff:c0a8:0103 GID[ 2]: 2001:0db1:0000:0000:020e:1eff:fe50:c5b0 GID[ 3]: 2001:0db2:0000:0000:020e:1eff:fe50:c5b0 GID[ 4]: 0000:0000:0000:0000:0000:ffff:c0a8:0b03 IP address for vLAN interface GID[ 5]: fe80:0000:0000:0000:020e:1e00:0350:c5b0 vLAN ID 3

7RoCE Configuration Configuring RoCE on the Adapter for Linux

155 AH0054602-00 M

RoCE v2 Configuration for Linux To verify RoCE v2 functionality, you must use RoCE v2 supported kernels.

To configure RoCE v2 for Linux: 1. Ensure that you are using one of the following supported kernels:

SLES 15/15 SP1 SLES 12 SP4 and later RHEL 7.6, 7.7, and 8.0

2. Configure RoCE v2 as follows:

a. Identify the GID index for RoCE v2.

b. Configure the routing address for the server and client.

c. Enable L3 routing on the switch.

Identifying the RoCE v2 GID Index or Address To find RoCE v1- and RoCE v2-specific GIDs, use either sys or class parameters, or run RoCE scripts from the 41xxx FastLinQ source package. To check the default RoCE GID Index and address, issue the ibv_devinfo command and compare it with the sys or class parameters. For example:

#ibv_devinfo -d qedr0 -v|grep GID GID[ 0]: fe80:0000:0000:0000:020e:1eff:fec4:1b20 GID[ 1]: fe80:0000:0000:0000:020e:1eff:fec4:1b20 GID[ 2]: 0000:0000:0000:0000:0000:ffff:1e01:010a GID[ 3]: 0000:0000:0000:0000:0000:ffff:1e01:010a GID[ 4]: 3ffe:ffff:0000:0f21:0000:0000:0000:0004

NOTE The default GID value is zero (0) for back-to-back or pause settings. For server and switch configurations, you must identify the proper GID value. If you are using a switch, refer to the corresponding switch configuration documents for the correct settings.

NOTE You can configure RoCE v1 and RoCE v2 by using RoCE v2-supported kernels. These kernels allow you to run RoCE traffic over the same subnet, as well as over different subnets such as RoCE v2 and any routable environment. Only a few settings are required for RoCE v2, and all other switch and adapter settings are common for RoCE v1 and RoCE v2.

7RoCE Configuration Configuring RoCE on the Adapter for Linux

156 AH0054602-00 M

GID[ 5]: 3ffe:ffff:0000:0f21:0000:0000:0000:0004 GID[ 6]: 0000:0000:0000:0000:0000:ffff:c0a8:6403 GID[ 7]: 0000:0000:0000:0000:0000:ffff:c0a8:6403

Verifying the RoCE v1 or RoCE v2 GID Index and Address from sys and class Parameters

Use one of the following options to verify the RoCE v1 or RoCE v2 GID Index and address from the sys and class parameters:

Option 1: # cat /sys/class/infiniband/qedr0/ports/1/gid_attrs/types/0 IB/RoCE v1 # cat /sys/class/infiniband/qedr0/ports/1/gid_attrs/types/1 RoCE v2

# cat /sys/class/infiniband/qedr0/ports/1/gids/0 fe80:0000:0000:0000:020e:1eff:fec4:1b20 # cat /sys/class/infiniband/qedr0/ports/1/gids/1 fe80:0000:0000:0000:020e:1eff:fec4:1b20

Option 2: Use the scripts from the FastLinQ source package.

#/../fastlinq-8.x.x.x/add-ons/roce/show_gids.sh DEV PORT INDEX GID IPv4 VER DEV --- ---- ----- --- ------------ --- --- qedr0 1 0 fe80:0000:0000:0000:020e:1eff:fec4:1b20 v1 p4p1 qedr0 1 1 fe80:0000:0000:0000:020e:1eff:fec4:1b20 v2 p4p1 qedr0 1 2 0000:0000:0000:0000:0000:ffff:1e01:010a 30.1.1.10 v1 p4p1 qedr0 1 3 0000:0000:0000:0000:0000:ffff:1e01:010a 30.1.1.10 v2 p4p1 qedr0 1 4 3ffe:ffff:0000:0f21:0000:0000:0000:0004 v1 p4p1 qedr0 1 5 3ffe:ffff:0000:0f21:0000:0000:0000:0004 v2 p4p1 qedr0 1 6 0000:0000:0000:0000:0000:ffff:c0a8:6403 192.168.100.3 v1 p4p1.100 qedr0 1 7 0000:0000:0000:0000:0000:ffff:c0a8:6403 192.168.100.3 v2 p4p1.100 qedr1 1 0 fe80:0000:0000:0000:020e:1eff:fec4:1b21 v1 p4p2 qedr1 1 1 fe80:0000:0000:0000:020e:1eff:fec4:1b21 v2 p4p2

7RoCE Configuration Configuring RoCE on the Adapter for Linux

157 AH0054602-00 M

Verifying the RoCE v1 or RoCE v2 Function Through perftest Applications

This section shows how to verify the RoCE v1 or RoCE v2 function through perftest applications. In this example, the following server IP and client IP are used:

Server IP: 192.168.100.3 Client IP: 192.168.100.4

Verifying RoCE v1 Run over the same subnet and use the RoCE v1 GID Index. Server# ib_send_bw -d qedr0 -F -x 0 Client# ib_send_bw -d qedr0 -F -x 0 192.168.100.3

Verifying RoCE v2 Run over the same subnet and use the RoCE v2 GID Index. Server# ib_send_bw -d qedr0 -F -x 1 Client# ib_send_bw -d qedr0 -F -x 1 192.168.100.3

Verifying RoCE v2 Through Different Subnets

NOTE You must specify the GID index values for RoCE v1- or RoCE v2-based server or switch configuration (Pause/PFC). Use the GID index for the link local IPv6 address, IPv4 address, or IPv6 address. To use vLAN tagged frames for RoCE traffic, you must specify GID index values that are derived from the vLAN IPv4 or IPv6 address.

NOTE If you are running through a switch PFC configuration, use vLAN GIDs for RoCE v1 or v2 through the same subnet.

NOTE You must first configure the route settings for the switch and servers. On the adapter, set the RoCE priority and DCBX mode using either the HII, UEFI user interface, or one of the Marvell management utilities.

7RoCE Configuration Configuring RoCE on the Adapter for Linux

158 AH0054602-00 M

To verify RoCE v2 through different subnets: 1. Set the route configuration for the server and client using the DCBX-PFC

configuration.

System Settings: Server VLAN IP : 192.168.100.3 and Gateway :192.168.100.1

Client VLAN IP :192.168.101.3 and Gateway :192.168.101.1

Server Configuration: #/sbin/ip link add link p4p1 name p4p1.100 type vlan id 100 #ifconfig p4p1.100 192.168.100.3/24 up #ip route add 192.168.101.0/24 via 192.168.100.1 dev p4p1.100 Client Configuration: #/sbin/ip link add link p4p1 name p4p1.101 type vlan id 101 #ifconfig p4p1.101 192.168.101.3/24 up #ip route add 192.168.100.0/24 via 192.168.101.1 dev p4p1.101

2. Set the switch settings using the following procedure.

Use any flow control method (Pause, DCBX-CEE, or DCBX-IEEE), and enable IP routing for RoCE v2. See Preparing the Ethernet Switch on page 129 for RoCE v2 configuration, or refer to the vendor switch documents.

If you are using PFC configuration and L3 routing, run RoCE v2 traffic over the vLAN using a different subnet, and use the RoCE v2 vLAN GID index. Server# ib_send_bw -d qedr0 -F -x 5 Client# ib_send_bw -d qedr0 -F -x 5 192.168.100.3

7RoCE Configuration Configuring RoCE on the Adapter for Linux

159 AH0054602-00 M

Server Switch Settings:

Figure 7-12. Switch Settings, Server

Client Switch Settings:

Figure 7-13. Switch Settings, Client

7RoCE Configuration Configuring RoCE on the Adapter for Linux

160 AH0054602-00 M

Configuring RoCE v1 or RoCE v2 Settings for RDMA_CM Applications To configure RoCE, use the following scripts from the FastLinQ source package: # ./show_rdma_cm_roce_ver.sh qedr0 is configured to IB/RoCE v1 qedr1 is configured to IB/RoCE v1

# ./config_rdma_cm_roce_ver.sh v2 configured rdma_cm for qedr0 to RoCE v2 configured rdma_cm for qedr1 to RoCE v2 Server Settings:

Figure 7-14. Configuring RDMA_CM Applications: Server

Client Settings:

Figure 7-15. Configuring RDMA_CM Applications: Client

Configuring RoCE for SR-IOV VF Devices (VF RDMA) The following sections describe how to configure RoCE for SR-IOV VF devices (also referred to as VFRMDA) on Linux. Associated information and limitations are also provided.

7RoCE Configuration Configuring RoCE on the Adapter for Linux

161 AH0054602-00 M

Table 7-4 lists the supported Linux OS combinations.

If you are using the inbox OFED, use the same OFED distribution between the hypervisor host OS and the guest (VM) OS. Check the out-of-box OFED distribution release notes for their specific supported host OS-to-VM OS distribution matrix.

Enumerating VFs for L2 and RDMA There are two ways to enumerate the VFs:

User Defined VF MAC Allocation

Dynamic or Random VF MAC Allocation

User Defined VF MAC Allocation When defining the VF MAC allocation, there are no changes in the default VF enumeration method. After creating the number of VFs, assign the static MAC address.

To create a user defined VF MAC allocation: 1. Enumerate the default VF.

# modprobe -v qede # echo 2 > /sys/class/net/p6p1/device/sriov_numvfs # ip link show 14: p6p1: mtu 1500 qdisc mq state DOWN mode DEFAULT group default qlen 1000

link/ether 14:02:ec:ce:d0:e4 brd ff:ff:ff:ff:ff:ff vf 0 MAC 00:00:00:00:00:00, spoof checking off, link-state auto

Table 7-4. Supported Linux OSs for VF RDMA

Guest OS

Hypervisor RHEL

7.6 RHEL

7.7 RHEL

8.0 SLES12

SP4 SLES15

SP0 SLES15

SP1

Yes Yes Yes Yes Yes Yes

RHEL 7.7 Yes Yes Yes Yes Yes Yes

RHEL 8.0 Yes Yes Yes Yes Yes Yes

SLES12 SP4 Yes Yes Yes Yes Yes Yes

SLES15 SP0 Yes Yes Yes Yes Yes Yes

SLES15 SP1 Yes Yes Yes Yes Yes Yes

7RoCE Configuration Configuring RoCE on the Adapter for Linux

162 AH0054602-00 M

vf 1 MAC 00:00:00:00:00:00, spoof checking off, link-state auto 2. Assign the static MAC address:

# ip link set dev p6p1 vf 0 mac 3c:33:44:55:66:77 # ip link set dev p6p1 vf 1 mac 3c:33:44:55:66:89 #ip link show 14: p6p1: mtu 1500 qdisc mq state UP mode DEFAULT group default qlen 1000

link/ether 14:02:ec:ce:d0:e4 brd ff:ff:ff:ff:ff:ff vf 0 MAC 3c:33:44:55:66:77, tx rate 25000 (Mbps), max_tx_rate 25000Mbps, spoof checking off,

link-state auto vf 1 MAC 3c:33:44:55:66:89, tx rate 25000 (Mbps), max_tx_rate 25000Mbps, spoof checking off,

link-state auto

3. To reflect for RDMA, load/unload the qedr driver if it is already loaded. #rmmod qedr #modprobe qedr #ibv_devices

device node GUID ------ ---------------- qedr0 1602ecfffeced0e4 qedr1 1602ecfffeced0e5 qedr_vf0 3e3344fffe556677 qedr_vf1 3e3344fffe556689

Dynamic or Random VF MAC Allocation To dynamically allocate a VF MAC: # modprobe -r qedr # modprobe -v qed vf_mac_origin=3 [Use this module parameter for dynamic MAC allocation] # modprobe -v qede # echo 2 > /sys/class/net/p6p1/device/sriov_numvfs # modprobe qedr (This is an optional, mostly qedr driver loads itself) # ip link show|grep vf

vf 0 MAC ba:1a:ad:08:89:00, tx rate 25000 (Mbps), max_tx_rate 25000Mbps, spoof checking off, link-state auto

vf 1 MAC 96:40:61:49:cd:68, tx rate 25000 (Mbps), max_tx_rate 25000Mbps, spoof checking off, link-state auto # lsmod |grep qedr # ibv_devices

7RoCE Configuration Configuring RoCE on the Adapter for Linux

163 AH0054602-00 M

device node GUID ------ ---------------- qedr0 1602ecfffececfa0 qedr1 1602ecfffececfa1 qedr_vf0 b81aadfffe088900 qedr_vf1 944061fffe49cd68

Number of VFs Supported for RDMA For the 41xxx Series Adapters, the number of VFs for L2 and RDMA are shared based on resources availability.

Dual Port Adapters Each PF supports a maximum of 40 VFs for RDMA. If the number of VFs exceeds 56, it will be subtracted by the total number of VFs (96).

In the following example, PF0 is /sys/class/net/ /device/sriov_numvfs Echo 40 > PF0 (VFs for L2+RDMA=40+40 (40 VFs can use for both L2 and RDMA)) Echo 56 > PF0 (VFs for L2+RDMA=56+40)

After crossing 56 VFs, this number is subtracted by the total number of VFs. For example:

echo 57 > PF0 then 96-57=39 VFs for RDMA (57 VFs for L2 + 39VFs for RDMA) echo 96 > PF0 then 96-96=0 VFs for RDMA (all 96 VFs can use only for L2)

To view the available VFs for L2 and RDMA: L2 : # ip link show RDMA: # ibv_devices

Quad Port Adapters Each PF supports a maximum of 20 VFs for RDMA; until 48 VFs, there are 20 VFs for RDMA. When exceeding 28 VFs, that number is subtracted by the total VFs (48).

For example, in a 4x10G: Echo 20 > PF0 (VFs for L2+RDMA=20+20) Echo 28 > PF0 (VFs for L2+RDMA=28+20)

When exceeding 28 VFs, this number is subtracted by the total number of VFs. For example: echo 29 > PF0 (4829=19VFs for RDMA; 29 VFs for L2 + 19 VFs for RDMA) echo 48 > PF0 (48-48=0 VFs for RDMA; all 48 VFs can use only for L2)

7RoCE Configuration Configuring RoCE on the Adapter for VMware ESX

164 AH0054602-00 M

Limitations VF RMDA has the following limitations:

No iWARP support

No NPAR support

Cross OS is not supported; for example, a Linux hypervisor cannot use a Windows guest OS (VM)

Perftest latency test on VF interfaces can be run only with the inline size zero -I 0 option. Neither the default nor more than one inline size works.

To allow RDMA_CM applications to run on different MTU sizes (5129000) other than the default (1500), follow these steps:

1. Unload the qedr driver: #rmmod qedr

2. Set MTU on the VF interface: #ifconfig mtu 9000

3. Load the qedr driver: #modprobe qedr

The rdma_server/rdma_xserver does not support VF interfaces.

No RDMA bonding support on VFs.

Configuring RoCE on the Adapter for VMware ESX This section provides the following procedures and information for RoCE configuration:

Configuring RDMA Interfaces

Configuring MTU

RoCE Mode and Statistics

Configuring a Paravirtual RDMA Device (PVRDMA)

NOTE Mapping Ethernet speeds to RDMA speeds is not always accurate, because values that can be specified by the RoCE driver are aligned with Infiniband. For example, if RoCE is configured on an Ethernet interface operating at 1Gbps, the RDMA speed is shown as 2.5Gbps. There are no other suitable values available in the header files provided by ESXi that can be used by the RoCE driver to indicate 1Gbps speed.

7RoCE Configuration Configuring RoCE on the Adapter for VMware ESX

165 AH0054602-00 M

Configuring RDMA Interfaces To configure the RDMA interfaces: 1. Install both Marvell NIC and RoCE drivers.

2. Using the module parameter, enable the RoCE function from the NIC driver by issuing the following command: esxcfg-module -s 'enable_roce=1' qedentv To apply the change, reload the NIC driver or reboot the system.

3. To view a list of the NIC interfaces, issue the esxcfg-nics -l command. For example:

esxcfg-nics -l Name PCI Driver Link Speed Duplex MAC Address MTU Description Vmnic0 0000:01:00.2 qedentv Up 25000Mbps Full a4:5d:36:2b:6c:92 1500 QLogic Corp. QLogic FastLinQ QL41xxx 1/10/25 GbE Ethernet Adapter Vmnic1 0000:01:00.3 qedentv Up 25000Mbps Full a4:5d:36:2b:6c:93 1500 QLogic Corp. QLogic FastLinQ QL41xxx 1/10/25 GbE Ethernet Adapter

4. To view a list of the RDMA devices, issue the esxcli rdma device list command. For example:

esxcli rdma device list Name Driver State MTU Speed Paired Uplink Description ------- ------- ------ ---- ------- ------------- ------------------------------- vmrdma0 qedrntv Active 1024 25 Gbps vmnic0 QLogic FastLinQ QL45xxx RDMA Interface vmrdma1 qedrntv Active 1024 25 Gbps vmnic1 QLogic FastLinQ QL45xxx RDMA Interface

5. To create a new virtual switch, issue the following command: esxcli network vswitch standard add -v For example: # esxcli network vswitch standard add -v roce_vs This creates a new virtual switch named roce_vs.

6. To associate the Marvell NIC port to the vSwitch, issue the following command: # esxcli network vswitch standard uplink add -u device> -v For example: # esxcli network vswitch standard uplink add -u vmnic0 -v roce_vs

7RoCE Configuration Configuring RoCE on the Adapter for VMware ESX

166 AH0054602-00 M

7. To create a new port group on this vSwitch, issue the following command: # esxcli network vswitch standard portgroup add -p roce_pg -v roce_vs For example: # esxcli network vswitch standard portgroup add -p roce_pg -v roce_vs

8. To create a vmknic interface on this port group and configure the IP, issue the following command: # esxcfg-vmknic -a -i -n group name> For example: # esxcfg-vmknic -a -i 192.168.10.20 -n 255.255.255.0 roce_pg

9. To configure the vLAN ID, issue the following command: # esxcfg-vswitch -v -p roce_pg To run RoCE traffic with a vLAN ID, configure the vLAN ID on the corresponding VMkernel port group.

Configuring MTU To modify the MTU for an RoCE interface, change the MTU of the corresponding vSwitch. Set the MTU size of the RDMA interface based on the MTU of the vSwitch by issuing the following command: # esxcfg-vswitch -m For example:

# esxcfg-vswitch -m 4000 roce_vs # esxcli rdma device list Name Driver State MTU Speed Paired Uplink Description ------- ------- ------ ---- ------- ------------- ------------------------------- vmrdma0 qedrntv Active 2048 25 Gbps vmnic0 QLogic FastLinQ QL45xxx RDMA Interface vmrdma1 qedrntv Active 1024 25 Gbps vmnic1 QLogic FastLinQ QL45xxx RDMA Interface

RoCE Mode and Statistics For the RoCE mode, ESXi requires concurrent support of both RoCE v1 and v2. The decision regarding which RoCE mode to use is made during queue pair creation. The ESXi driver advertises both modes during registration and initialization. To view RoCE statistics, issue the following command: # esxcli rdma device stats get -d vmrdma0

7RoCE Configuration Configuring RoCE on the Adapter for VMware ESX

167 AH0054602-00 M

Packets received: 0 Packets sent: 0 Bytes received: 0 Bytes sent: 0 Error packets received: 0 Error packets sent: 0 Error length packets received: 0 Unicast packets received: 0 Multicast packets received: 0 Unicast bytes received: 0 Multicast bytes received: 0 Unicast packets sent: 0 Multicast packets sent: 0 Unicast bytes sent: 0 Multicast bytes sent: 0 Queue pairs allocated: 0 Queue pairs in RESET state: 0 Queue pairs in INIT state: 0 Queue pairs in RTR state: 0 Queue pairs in RTS state: 0 Queue pairs in SQD state: 0 Queue pairs in SQE state: 0 Queue pairs in ERR state: 0 Queue pair events: 0 Completion queues allocated: 1 Completion queue events: 0 Shared receive queues allocated: 0 Shared receive queue events: 0 Protection domains allocated: 1 Memory regions allocated: 3 Address handles allocated: 0 Memory windows allocated: 0

Configuring a Paravirtual RDMA Device (PVRDMA) See VMware's documentation (for example, https://kb.vmware.com/articleview?docid=2147694) for details on configuring PVRDMA using a vCenter interface. The following instructions are only for reference.

7RoCE Configuration Configuring RoCE on the Adapter for VMware ESX

168 AH0054602-00 M

To configure PVRDMA using a vCenter interface: 1. Create and configure a new distributed virtual switch as follows:

a. In the VMware vSphere Web Client, right-click the RoCE node in the left pane of the Navigator window.

b. On the Actions menu, point to Distributed Switch, and then click New Distributed Switch.

c. Select version 6.5.0.

d. Under New Distributed Switch, click Edit settings, and then configure the following:

Number of uplinks. Select an appropriate value.

Network I/O Control. Select Disabled.

Default port group. Select the Create a default port group check box.

Port group name. Type a name for the port group.

Figure 7-16 shows an example.

Figure 7-16. Configuring a New Distributed Switch

2. Configure a distributed virtual switch as follows:

a. In the VMware vSphere Web Client, expand the RoCE node in the left pane of the Navigator window.

b. Right-click RoCE-VDS, and then click Add and Manage Hosts.

c. Under Add and Manage Hosts, configure the following:

Assign uplinks. Select from the list of available uplinks.

Manage VMkernel network adapters. Accept the default, and then click Next.

Migrate VM networking. Assign the port group created in Step 1.

7RoCE Configuration Configuring RoCE on the Adapter for VMware ESX

169 AH0054602-00 M

3. Assign a vmknic for PVRDMA to use on ESX hosts:

a. Right-click a host, and then click Settings.

b. On the Settings page, expand the System node, and then click Advanced System Settings.

c. The Advanced System Settings page shows the key-pair value and its summary. Click Edit.

d. On the Edit Advanced System Settings page, filter on PVRDMA to narrow all the settings to just Net.PVRDMAVmknic.

e. Set the Net.PVRDMAVmknic value to vmknic; for example, vmk1.

Figure 7-17 shows an example.

Figure 7-17. Assigning a vmknic for PVRDMA

4. Set the firewall rule for the PVRDMA:

a. Right-click a host, and then click Settings.

b. On the Settings page, expand the System node, and then click Security Profile.

c. On the Firewall Summary page, click Edit. d. In the Edit Security Profile dialog box under Name, scroll down, select

the pvrdma check box, and then select the Set Firewall check box.

7RoCE Configuration Configuring RoCE on the Adapter for VMware ESX

170 AH0054602-00 M

Figure 7-18 shows an example.

Figure 7-18. Setting the Firewall Rule

5. Set up the VM for PVRDMA as follows:

a. Install the following supported guest OS:

RHEL 7.5, 7.6, and 8.0

b. Install OFED4.17-1.

c. Compile and install the PVRDMA guest driver and library.

d. Add a new PVRDMA network adapter to the VM as follows:

Edit the VM settings. Add a new network adapter. Select the newly added DVS port group as Network. Select PVRDMA as the adapter type.

e. After the VM is booted, ensure that the PVRDMA guest driver is loaded.

7RoCE Configuration Configuring DCQCN

171 AH0054602-00 M

Configuring DCQCN Data Center Quantized Congestion Notification (DCQCN) is a feature that determines how an RoCE receiver notifies a transmitter that a switch between them has provided an explicit congestion notification (notification point), and how a transmitter reacts to such notification (reaction point).

This section provides the following information about DCQCN configuration:

DCQCN Terminology

DCQCN Overview

DCB-related Parameters

Global Settings on RDMA Traffic

Configuring DSCP-PFC

Enabling DCQCN

Configuring CNP

DCQCN Algorithm Parameters

MAC Statistics

Script Example

Limitations

DCQCN Terminology The following terms describe DCQCN configuration:

ToS (type of service) is a single-byte in the IPv4 header field. ToS comprises two ECN least significant bits (LSB) and six Differentiated Services Code Point (DSCP) most significant bits (MSB). For IPv6, traffic class is the equivalent of the IPv4 ToS.

ECN (explicit congestion notification) is a mechanism where a switch adds to outgoing traffic an indication that congestion is imminent.

CNP (congestion notification packet) is a packet used by the notification point to indicate that the ECN arrived from the switch back to the reaction point. CNP is defined in the Supplement to InfiniBand Architecture Specification Volume 1 Release 1.2.1, located here:

https://cw.infinibandta.org/document/dl/7781

VLAN Priority is a field in the L2 vLAN header. The field is the three MSBs in the vLAN tag.

PFC (priority-based flow control) is a flow control mechanism that applies to traffic carrying a specific vLAN priority.

7RoCE Configuration Configuring DCQCN

172 AH0054602-00 M

DSCP-PFC is a feature that allows a receiver to interpret the priority of an incoming packet for PFC purposes, rather than according to the vLAN priority or the DSCP field in the IPv4 header. You may use an indirection table to indicate a specified DSCP value to a vLAN priority value. DSCP-PFC can work across L2 networks because it is an L3 (IPv4) feature.

Traffic classes, also known as priority groups, are groups of vLAN priorities (or DSCP values if DSCP-PFC is used) that can have properties such as being lossy or lossless. Generally, 0 is used for the default common lossy traffic group, 3 is used for the FCoE traffic group, and 4 is used for the iSCSI-TLV traffic group. You may encounter DCB mismatch issues if you attempt to reuse these numbers on networks that also support FCoE or iSCSI-TLV traffic. Marvell recommends that you use numbers 12 or 57 for RoCE-related traffic groups.

ETS (enhanced transition services) is an allocation of maximum bandwidth per traffic class.

DCQCN Overview Some networking protocols (RoCE, for example) require droplessness. PFC is a mechanism for achieving droplessness in an L2 network, and DSCP-PFC is a mechanism for achieving it across distinct L2 networks. However, PFC is deficient in the following regards:

When activated, PFC completely halts the traffic of the specified priority on the port, as opposed to reducing transmission rate.

All traffic of the specified priority is affected, even if there is a subset of specific connections that are causing the congestion.

PFC is a single-hop mechanism. That is, if a receiver experiences congestion and indicates the congestion through a PFC packet, only the nearest neighbor will react. When the neighbor experiences congestion (likely because it can no longer transmit), it also generates its own PFC. This generation is known as pause propagation. Pause propagation may cause inferior route utilization, because all buffers must congest before the transmitter is made aware of the problem.

DCQCN addresses all of these disadvantages. The ECN delivers congestion indication to the reaction point. The reaction point sends a CNP packet to the transmitter, which reacts by reducing its transmission rate and avoiding the congestion. DCQCN also specifies how the transmitter attempts to increase its transmission rate and use bandwidth effectively after congestion ceases. DCQCN is described in the 2015 SIGCOMM paper, Congestion Control for Large-Scale RDMA Deployments, located here:

http://conferences.sigcomm.org/sigcomm/2015/pdf/papers/p523.pdf

7RoCE Configuration Configuring DCQCN

173 AH0054602-00 M

DCB-related Parameters Use DCB to map priorities to traffic classes (priority groups). DCB also controls which priority groups are subject to PFC (lossless traffic), and the related bandwidth allocation (ETS).

Global Settings on RDMA Traffic Global settings on RDMA traffic include configuration of vLAN priority, ECN, and DSCP.

Setting vLAN Priority on RDMA Traffic Use an application to set the vLAN priority used by a specified RDMA Queue Pair (QP) when creating a QP. For example, the ib_write_bw benchmark controls the priority using the -sl parameter. When RDMA-CM (RDMA Communication Manager) is present, you may be unable to set the priority.

Another method to control the vLAN priority is to use the rdma_glob_vlan_pri node. This method affects QPs that are created after setting the value. For example, to set the vLAN priority number to 5 for subsequently created QPs, issue the following command: ./debugfs.sh -n eth0 -t rdma_glob_vlan_pri 5

Setting ECN on RDMA Traffic Use the rdma_glob_ecn node to enable ECN for a specified RoCE priority. For example, to enable ECN on RoCE traffic using priority 5, issue the following command: ./debugfs.sh -n eth0 -t rdma_glob_ecn 1 This command is typically required when DCQCN is enabled.

Setting DSCP on RDMA Traffic Use the rdma_glob_dscp node to control DSCP. For example, to set DSCP on RoCE traffic using priority 5, issue the following command: ./debugfs.sh -n eth0 -t rdma_glob_dscp 6 This command is typically required when DCQCN is enabled.

Configuring DSCP-PFC Use dscp_pfc nodes to configure the dscp->priority association for PFC. You must enable the feature before you can add entries to the map. For example, to map DSCP value 6 to priority 5, issue the following commands: ./debugfs.sh -n eth0 -t dscp_pfc_enable 1 ./debugfs.sh -n eth0 -t dscp_pfc_set 6 5

7RoCE Configuration Configuring DCQCN

174 AH0054602-00 M

Enabling DCQCN To enable DCQCN for RoCE traffic, probe the qed driver with the dcqcn_enable module parameter. DCQCN requires enabled ECN indications (see Setting ECN on RDMA Traffic on page 173).

Configuring CNP Congestion notification packets (CNPs) can have a separate configuration of vLAN priority and DSCP. Control these packets using the dcqcn_cnp_dscp and dcqcn_cnp_vlan_priority module parameters. For example: modprobe qed dcqcn_cnp_dscp=10 dcqcn_cnp_vlan_priority=6

DCQCN Algorithm Parameters Table 7-5 lists the algorithm parameters for DCQCN.

Table 7-5. DCQCN Algorithm Parameters

Parameter Description and Values

dcqcn_cnp_send_timeout Minimal difference of send time between CNPs. Units are in microseconds. Values range between 50..500000.

dcqcn_cnp_dscp DSCP value to be used on CNPs. Values range between 0..63.

dcqcn_cnp_vlan_priority vLAN priority to be used on CNPs. Values range between 0..7. FCoE-Offload uses 3 and iSCSI-Offload-TLV generally uses 4. Marvell rec- ommends that you specify a number from 12 or 57. Use this same value throughout the entire net- work.

dcqcn_notification_point 0 Disable DCQCN notification point. 1 Enable DCQCN notification point.

dcqcn_reaction_point 0 Disable DCQCN reaction point. 1 Enable DCQCN reaction point.

dcqcn_rl_bc_rate Byte counter limit

dcqcn_rl_max_rate Maximum rate in Mbps

dcqcn_rl_r_ai Active increase rate in Mbps

dcqcn_rl_r_hai Hyperactive increase rate in Mbps.

dcqcn_gd Alpha update gain denominator. Set to 32 for 1/32, and so on.

7RoCE Configuration Configuring DCQCN

175 AH0054602-00 M

MAC Statistics To view MAC statistics, including per-priority PFC statistics, issue the phy_mac_stats command. For example, to view statistics on port 1 issue the following command: ./debugfs.sh -n eth0 -d phy_mac_stat -P 1

Script Example The following example can be used as a script: # probe the driver with both reaction point and notification point enabled # with cnp dscp set to 10 and cnp vlan priority set to 6 modprobe qed dcqcn_enable=1 dcqcn_notification_point=1 dcqcn_reaction_point=1 dcqcn_cnp_dscp=10 dcqcn_cnp_vlan_priority=6 modprobe qede

# dscp-pfc configuration (associating dscp values to priorities) # This example is using two DCBX traffic class priorities to better demonstrate DCQCN in operation debugfs.sh -n ens6f0 -t dscp_pfc_enable 1 debugfs.sh -n ens6f0 -t dscp_pfc_set 20 5 debugfs.sh -n ens6f0 -t dscp_pfc_set 22 6

# static DCB configurations. 0x10 is static mode. Mark priorities 5 and 6 as # subject to pfc debugfs.sh -n ens6f0 -t dcbx_set_mode 0x10 debugfs.sh -n ens6f0 -t dcbx_set_pfc 5 1 debugfs.sh -n ens6f0 -t dcbx_set_pfc 6 1

# set roce global overrides for qp params. enable exn and open QPs with dscp 20 debugfs.sh -n ens6f0 -t rdma_glob_ecn 1 debugfs.sh -n ens6f0 -t rdma_glob_dscp 20

# open some QPs (DSCP 20) ib_write_bw -d qedr0 -q 16 -F -x 1 --run_infinitely

# change global dscp qp params debugfs.sh -n ens6f0 -t rdma_glob_dscp 22

# open some more QPs (DSCP 22) ib_write_bw -d qedr0 -q 16 -F -x 1 -p 8000 --run_infinitely

dcqcn_k_us Alpha update interval

dcqcn_timeout_us DCQCN timeout

Table 7-5. DCQCN Algorithm Parameters (Continued)

Parameter Description and Values

7RoCE Configuration Configuring DCQCN

176 AH0054602-00 M

# observe PFCs being generated on multiple priorities debugfs.sh -n ens6f0 -d phy_mac_stat -P 0 | grep "Class Based Flow Control"

Limitations DCQCN has the following limitations:

DCQCN mode currently supports only up to 64 QPs.

Marvell adapters can determine vLAN priority for PFC purposes from vLAN priority or from DSCP bits in the ToS field. However, in the presence of both, vLAN takes precedence.

177 AH0054602-00 M

8 iWARP Configuration

Internet wide area RDMA protocol (iWARP) is a computer networking protocol that implements RDMA for efficient data transfer over IP networks. iWARP is designed for multiple environments, including LANs, storage networks, data center networks, and WANs.

This chapter provides instructions for:

Preparing the Adapter for iWARP

Configuring iWARP on Windows on page 178

Configuring iWARP on Linux on page 182

Preparing the Adapter for iWARP This section provides instructions for preboot adapter iWARP configuration using the HII. For more information about preboot adapter configuration, see Chapter 5 Adapter Preboot Configuration.

To configure iWARP through HII in Default mode: 1. Access the server BIOS System Setup, and then click Device Settings.

2. On the Device Settings page, select a port for the 25G 41xxx Series Adapter.

3. On the Main Configuration Page for the selected adapter, click NIC Configuration.

4. On the NIC Configuration page:

a. Set the NIC + RDMA Mode to Enabled.

b. Set the RDMA Protocol Support to RoCE/iWARP or iWARP.

c. Click Back.

5. On the Main Configuration Page, click Finish.

NOTE Some iWARP features may not be fully enabled in the current release. For details, refer to Appendix D Feature Constraints.

8iWARP Configuration Configuring iWARP on Windows

178 AH0054602-00 M

6. In the Warning - Saving Changes message box, click Yes to save the configuration.

7. In the Success - Saving Changes message box, click OK.

8. Repeat Step 2 through Step 7 to configure the NIC and iWARP for the other ports.

9. To complete adapter preparation of both ports:

a. On the Device Settings page, click Finish.

b. On the main menu, click Finish.

c. Exit to reboot the system.

Proceed to Configuring iWARP on Windows on page 178 or Configuring iWARP on Linux on page 182.

Configuring iWARP on Windows This section provides procedures for enabling iWARP, verifying RDMA, and verifying iWARP traffic on Windows. For a list of OSs that support iWARP, see Table 7-1 on page 127.

To enable iWARP on the Windows host and verify RDMA: 1. Enable iWARP on the Windows host.

a. Open the Windows Device Manager, and then open the 41xxx Series Adapter NDIS Miniport Properties.

b. On the FastLinQ Adapter properties, click the Advanced tab.

c. On the Advanced page under Property, do the following:

Select Network Direct Functionality, and then select Enabled for the Value.

Select NetworkDirect Technology, and then select iWARP for the Value.

d. Click OK to save your changes and close the adapter properties.

8iWARP Configuration Configuring iWARP on Windows

179 AH0054602-00 M

2. Using Windows PowerShell, verify that RDMA is enabled. The Get-NetAdapterRdma command output (Figure 8-1) shows the adapters that support RDMA.

Figure 8-1. Windows PowerShell Command: Get-NetAdapterRdma

3. Using Windows PowerShell, verify that NetworkDirect is enabled. The Get-NetOffloadGlobalSetting command output (Figure 8-2) shows NetworkDirect as Enabled.

Figure 8-2. Windows PowerShell Command: Get-NetOffloadGlobalSetting

To verify iWARP traffic: 1. Map SMB drives and run iWARP traffic.

2. Launch Performance Monitor (Perfmon).

3. In the Add Counters dialog box, click RDMA Activity, and then select the adapter instances.

8iWARP Configuration Configuring iWARP on Windows

180 AH0054602-00 M

Figure 8-3 shows an example.

Figure 8-3. Perfmon: Add Counters

8iWARP Configuration Configuring iWARP on Windows

181 AH0054602-00 M

If iWARP traffic is running, counters appear as shown in the Figure 8-4 example.

Figure 8-4. Perfmon: Verifying iWARP Traffic

4. To verify the SMB connection:

a. At a command prompt, issue the net use command as follows: C:\Users\Administrator> net use New connections will be remembered.

Status Local Remote Network --------------------------------------------------------- OK F: \\192.168.10.10\Share1 Microsoft Windows Network The command completed successfully.

b. Issue the netstat -xan command as follows, where Share1 is mapped as an SMB share:

C:\Users\Administrator> netstat -xan Active NetworkDirect Connections, Listeners, ShareEndpoints

Mode IfIndex Type Local Address Foreign Address PID

Kernel 56 Connection 192.168.11.20:16159 192.168.11.10:445 0 Kernel 56 Connection 192.168.11.20:15903 192.168.11.10:445 0 Kernel 56 Connection 192.168.11.20:16159 192.168.11.10:445 0

NOTE .

For more information on how to view Marvell RDMA counters in Windows, see Viewing RDMA Counters on page 136.

8iWARP Configuration Configuring iWARP on Linux

182 AH0054602-00 M

Kernel 56 Connection 192.168.11.20:15903 192.168.11.10:445 0 Kernel 60 Listener [fe80::e11d:9ab5:a47d:4f0a%56]:445 NA 0 Kernel 60 Listener 192.168.11.20:445 NA 0 Kernel 60 Listener [fe80::71ea:bdd2:ae41:b95f%60]:445 NA 0 Kernel 60 Listener 192.168.11.20:16159 192.168.11.10:445 0

Configuring iWARP on Linux Marvell 41xxx Series Adapters support iWARP on the Linux Open Fabric Enterprise Distributions (OFEDs) listed in Table 7-1 on page 127.

iWARP configuration on a Linux system includes the following:

Installing the Driver

Configuring iWARP and RoCE

Detecting the Device

Supported iWARP Applications

Running Perftest for iWARP

Configuring NFS-RDMA

Installing the Driver Install the RDMA drivers as shown in Chapter 3 Driver Installation.

Configuring iWARP and RoCE

To enable iWARP and RoCE: 1. Unload all FastLinQ drivers as follows:

# modprobe -r qedr or modprobe -r qede 2. Use the following command syntax to change the RDMA protocol by loading

the qed driver with a port interface PCI ID (xx:xx.x) and an RDMA protocol value (p). # modprobe -v qed rdma_protocol_map=

NOTE This procedure applies only if you previously selected iWARP+RoCE as the value for the RDMA Protocol Support parameter during preboot configuration using HII (see Configuring NIC Parameters, Step 5 on page 51).

8iWARP Configuration Configuring iWARP on Linux

183 AH0054602-00 M

The RDMA protocol (p) values are as follows:

0Accept the default (RoCE) 1No RDMA 2RoCE 3iWARP

For example, to change the interface on the port given by 04:00.0 from RoCE to iWARP, issue the following command: # modprobe -v qed rdma_protocol_map=04:00.0-3

3. Load the RDMA driver by issuing the following command: # modprobe -v qedr

The following example shows the command entries to change the RDMA protocol to iWARP on multiple NPAR interfaces: # modprobe qed rdma_protocol_map=04:00.1-3,04:00.3-3,04:00.5-3, 04:00.7-3,04:01.1-3,04:01.3-3,04:01.5-3,04:01.7-3 # modprobe -v qedr # ibv_devinfo |grep iWARP transport: iWARP (1) transport: iWARP (1) transport: iWARP (1) transport: iWARP (1) transport: iWARP (1) transport: iWARP (1) transport: iWARP (1) transport: iWARP (1)

Detecting the Device To detect the device: 1. To verify whether RDMA devices are detected, view the dmesg logs:

# dmesg |grep qedr [10500.191047] qedr 0000:04:00.0: registered qedr0 [10500.221726] qedr 0000:04:00.1: registered qedr1

2. Issue the ibv_devinfo command, and then verify the transport type.

If the command is successful, each PCI function will show a separate hca_id. For example (if checking the second port of the above dual-port adapter): [root@localhost ~]# ibv_devinfo -d qedr1 hca_id: qedr1

8iWARP Configuration Configuring iWARP on Linux

184 AH0054602-00 M

transport: iWARP (1) fw_ver: 8.14.7.0 node_guid: 020e:1eff:fec4:c06e sys_image_guid: 020e:1eff:fec4:c06e vendor_id: 0x1077 vendor_part_id: 5718 hw_ver: 0x0 phys_port_cnt: 1 port: 1 state: PORT_ACTIVE (4) max_mtu: 4096 (5) active_mtu: 1024 (3) sm_lid: 0 port_lid: 0 port_lmc: 0x00 link_layer: Ethernet

Supported iWARP Applications Linux-supported RDMA applications for iWARP include the following:

ibv_devinfo, ib_devices

ib_send_bw/lat, ib_write_bw/lat, ib_read_bw/lat, ib_atomic_bw/lat For iWARP, all applications must use the RDMA communication manager (rdma_cm) using the -R option.

rdma_server, rdma_client

rdma_xserver, rdma_xclient

rping

NFS over RDMA (NFSoRDMA)

iSER (for details, see Chapter 9 iSER Configuration)

NVMe-oF (for details, see Chapter 13 NVMe-oF Configuration with RDMA)

8iWARP Configuration Configuring iWARP on Linux

185 AH0054602-00 M

Running Perftest for iWARP All perftest tools are supported over the iWARP transport type. You must run the tools using the RDMA connection manager (with the -R option).

Example: 1. On one server, issue the following command (using the second port in this

example): # ib_send_bw -d qedr1 -F -R

2. On one client, issue the following command (using the second port in this example):

[root@localhost ~]# ib_send_bw -d qedr1 -F -R 192.168.11.3 ---------------------------------------------------------------------------- Send BW Test Dual-port : OFF Device : qedr1 Number of qps : 1 Transport type : IW Connection type : RC Using SRQ : OFF TX depth : 128 CQ Moderation : 100 Mtu : 1024[B] Link type : Ethernet GID index : 0 Max inline data : 0[B] rdma_cm QPs : ON Data ex. method : rdma_cm ---------------------------------------------------------------------------- local address: LID 0000 QPN 0x0192 PSN 0xcde932 GID: 00:14:30:196:192:110:00:00:00:00:00:00:00:00:00:00 remote address: LID 0000 QPN 0x0098 PSN 0x46fffc GID: 00:14:30:196:195:62:00:00:00:00:00:00:00:00:00:00 ---------------------------------------------------------------------------- #bytes #iterations BW peak[MB/sec] BW average[MB/sec] MsgRate[Mpps] 65536 1000 2250.38 2250.36 0.036006 ----------------------------------------------------------------------------

8iWARP Configuration Configuring iWARP on Linux

186 AH0054602-00 M

Configuring NFS-RDMA NFS-RDMA for iWARP includes both server and client configuration steps.

To configure the NFS server: 1. Create an nfs-server directory and grant permission by issuing the

following commands: # mkdir /tmp/nfs-server # chmod 777 /tmp/nfs-server

2. In the /etc/exports file for the directories that you must export using NFS-RDMA on the server, make the following entry: /tmp/nfs-server *(rw,fsid=0,async,insecure,no_root_squash)

Ensure that you use a different file system identification (FSID) for each directory that you export.

3. Load the svcrdma module as follows: # modprobe svcrdma

4. Load the service as follows:

For SLES, enable and start the NFS server alias: # systemctl enable|start|status nfsserver

For RHEL, enable and start the NFS server and services: # systemctl enable|start|status nfs

5. Include the default RDMA port 20049 into this file as follows: # echo rdma 20049 > /proc/fs/nfsd/portlist

6. To make local directories available for NFS clients to mount, issue the exportfs command as follows: # exportfs -v

NOTE For latency applications (send/write), if the perftest version is the latest (for example, perftest-3.0-0.21.g21dc344.x86_64.rpm), use the supported inline size value: 0-128.

8iWARP Configuration Configuring iWARP on Linux

187 AH0054602-00 M

To configure the NFS client:

1. Create an nfs-client directory and grant permission by issuing the following commands: # mkdir /tmp/nfs-client # chmod 777 /tmp/nfs-client

2. Load the xprtrdma module as follows: # modprobe xprtrdma

3. Mount the NFS file system as appropriate for your version:

For NFS Version 3: # mount -o rdma,port=20049 192.168.2.4:/tmp/nfs-server /tmp/nfs-client For NFS Version 4: # mount -t nfs4 -o rdma,port=20049 192.168.2.4:/tmp/nfs-server /tmp/nfs-client

4. Verify that the file system is mounted by issuing the mount command. Ensure that the RDMA port and file system versions are correct. # mount |grep rdma

NOTE This procedure for NFS client configuration also applies to RoCE.

NOTE The default port for NFSoRDMA is 20049. However, any other port that is aligned with the NFS client will also work.

188 AH0054602-00 M

9 iSER Configuration

This chapter provides procedures for configuring iSCSI Extensions for RDMA (iSER) for Linux (RHEL and SLES) and VMware ESXi 6.7, including:

Before You Begin

Configuring iSER for RHEL on page 189

Configuring iSER for SLES 12 and Later on page 192

Using iSER with iWARP on RHEL and SLES on page 193

Optimizing Linux Performance on page 195

Configuring iSER on ESXi 6.7 on page 196

Before You Begin As you prepare to configure iSER, consider the following:

iSER is supported only in inbox OFED for the following operating systems:

RHEL 8.x RHEL 7.6 and later SLES 12 SP4 and later SLES 15 SP0 and later VMware ESXi 6.7 U1

After logging into the targets or while running I/O traffic, unloading the Linux RoCE qedr driver may crash the system.

While running I/O, performing interface down/up tests or performing cable pull-tests can cause driver or iSER module errors that may crash the system. If this happens, reboot the system.

9iSER Configuration Configuring iSER for RHEL

189 AH0054602-00 M

Configuring iSER for RHEL To configure iSER for RHEL: 1. Install inbox OFED as described in RoCE Configuration for RHEL on

page 150.

2. Unload any existing FastLinQ drivers as described in Removing the Linux Drivers on page 10.

3. Install the latest FastLinQ driver and libqedr packages as described in Installing the Linux Drivers with RDMA on page 14.

4. Load the RDMA services as follows: systemctl start rdma modprobe qedr modprobe ib_iser modprobe ib_isert

5. Verify that all RDMA and iSER modules are loaded on the initiator and target devices by issuing the lsmod | grep qed and lsmod | grep iser commands.

6. Verify that there are separate hca_id instances by issuing the ibv_devinfo command, as shown in Step 6 on page 153.

7. Check the RDMA connection on the initiator device and the target device.

a. On the initiator device, issue the following command: rping -s -C 10 -v

b. On the target device, issue the following command: rping -c -a 192.168.100.99 -C 10 -v

NOTE Out-of-box OFEDs are not supported for iSER because the ib_isert module is not available in the out-of-box OFED 3.18-2 GA/3.18-3 GA versions. The inbox ib_isert module does not work with any out-of-box OFED versions.

9iSER Configuration Configuring iSER for RHEL

190 AH0054602-00 M

Figure 9-1 shows an example of a successful RDMA ping.

Figure 9-1. RDMA Ping Successful

8. You can use a Linux TCM-LIO target to test iSER. The setup is the same for any iSCSI target, except that you issue the command enable_iser Boolean=true on the applicable portals. The portal instances are identified as iser in Figure 9-2.

Figure 9-2. iSER Portal Instances

9. Install Linux iSCSI Initiator Utilities using the yum install iscsi-initiator-utils commands.

a. To discover the iSER target, issue the iscsiadm command. For example: iscsiadm -m discovery -t st -p 192.168.100.99:3260

9iSER Configuration Configuring iSER for RHEL

191 AH0054602-00 M

b. To change the transport mode to iSER, issue the iscsiadm command. For example: iscsiadm -m node -T iqn.2015-06.test.target1 -o update -n iface.transport_name -v iser

c. To connect to or log in to the iSER target, issue the iscsiadm command. For example: iscsiadm -m node -l -p 192.168.100.99:3260 -T iqn.2015-06.test.target1

d. Confirm that the Iface Transport is iser in the target connection, as shown in Figure 9-3. Issue the iscsiadm command; for example: iscsiadm -m session -P2

Figure 9-3. Iface Transport Confirmed

e. To check for a new iSCSI device, as shown in Figure 9-4, issue the lsscsi command.

9iSER Configuration Configuring iSER for SLES 12 and Later

192 AH0054602-00 M

Figure 9-4. Checking for New iSCSI Device

Configuring iSER for SLES 12 and Later Because the targetcli is not inbox on SLES 12 and later, you must complete the following procedure.

To configure iSER for SLES 12 and later: 1. Install targetcli.

For SLES 12:

Locate, copy and install the following RPMs from the ISO image (x86_64 and noarch location).

lio-utils-4.1-14.6.x86_64.rpm python-configobj-4.7.2-18.10.noarch.rpm python-PrettyTable-0.7.2-8.5.noarch.rpm python-configshell-1.5-1.44.noarch.rpm python-pyparsing-2.0.1-4.10.noarch.rpm python-netifaces-0.8-6.55.x86_64.rpm python-rtslib-2.2-6.6.noarch.rpm python-urwid-1.1.1-6.144.x86_64.rpm targetcli-2.1-3.8.x86_64.rpm For SLES 15 and SLES 15 SP1:

Load the SLES Package DVD and install targetcli by issuing the following Zypper command, which installs all the dependency packages: # zypper install python3-targetcli-fb

2. Before starting the targetcli, load all RoCE device drivers and iSER modules as follows: # modprobe qed # modprobe qede # modprobe qedr # modprobe ib_iser (initiator) # modprobe ib_isert (target)

9iSER Configuration Using iSER with iWARP on RHEL and SLES

193 AH0054602-00 M

3. Before configuring iSER targets, configure NIC interfaces and run L2 and RoCE traffic, as described in Step 7 on page 153.

4. For SLES 15 and SLES 15 SP1, insert the SLES Package DVD and install the targetcli utility. This command also installs all the dependency packages. # zypper install python3-targetcli-fb

5. Start the targetcli utility, and configure your targets on the iSER target system.

Using iSER with iWARP on RHEL and SLES Configure the iSER initiator and target similar to RoCE to work with iWARP. You can use different methods to create a Linux-IO (LIO) target; one is listed in this section. You may encounter some difference in targetcli configuration in SLES 12 and RHEL 7.x because of the version.

To configure a target for LIO: 1. Create an LIO target using the targetcli utility. Issue the following command:

# targetcli targetcli shell version 2.1.fb41 Copyright 2011-2013 by Datera, Inc and others. For help on commands, type 'help'.

2. Issue the following commands: /> /backstores/ramdisk create Ramdisk1-1 1g nullio=true /> /iscsi create iqn.2017-04.com.org.iserport1.target1 /> /iscsi/iqn.2017-04.com.org.iserport1.target1/tpg1/luns create /backstores/ramdisk/Ramdisk1-1 /> /iscsi/iqn.2017-04.com.org.iserport1.target1/tpg1/portals/ create 192.168.21.4 ip_port=3261 /> /iscsi/iqn.2017-04.com.org.iserport1.target1/tpg1/portals/192.168.21.4:3261 enable_iser boolean=true /> /iscsi/iqn.2017-04.com.org.iserport1.target1/tpg1 set attribute authentication=0 demo_mode_write_protect=0 generate_node_acls=1 cache_dynamic_acls=1 /> saveconfig

NOTE targetcli versions are different in RHEL and SLES. Be sure to use the proper backstores to configure your targets: RHEL uses ramdisk SLES uses rd_mcp

9iSER Configuration Using iSER with iWARP on RHEL and SLES

194 AH0054602-00 M

Figure 9-5 shows the target configuration for LIO.

Figure 9-5. LIO Target Configuration

To configure an initiator for iWARP: 1. To discover the iSER LIO target using port 3261, issue the iscsiadm

command as follows: # iscsiadm -m discovery -t st -p 192.168.21.4:3261 -I iser 192.168.21.4:3261,1 iqn.2017-04.com.org.iserport1.target1

2. Change the transport mode to iser as follows: # iscsiadm -m node -o update -T iqn.2017-04.com.org.iserport1.target1 -n iface.transport_name -v iser

3. Log into the target using port 3261: # iscsiadm -m node -l -p 192.168.21.4:3261 -T iqn.2017-04.com.org.iserport1.target1 Logging in to [iface: iser, target: iqn.2017-04.com.org.iserport1.target1, portal: 192.168.21.4,3261] (multiple) Login to [iface: iser, target: iqn.2017-04.com.org.iserport1.target1, portal: 192.168.21.4,3261] successful.

4. Ensure that those LUNs are visible by issuing the following command: # lsscsi [1:0:0:0] storage HP P440ar 3.56 - [1:1:0:0] disk HP LOGICAL VOLUME 3.56 /dev/sda [6:0:0:0] cd/dvd hp DVD-ROM DUD0N UMD0 /dev/sr0 [7:0:0:0] disk LIO-ORG Ramdisk1-1 4.0 /dev/sdb

9iSER Configuration Optimizing Linux Performance

195 AH0054602-00 M

Optimizing Linux Performance Consider the following Linux performance configuration enhancements described in this section.

Configuring CPUs to Maximum Performance Mode

Configuring Kernel sysctl Settings

Configuring IRQ Affinity Settings

Configuring Block Device Staging

Configuring CPUs to Maximum Performance Mode Configure the CPU scaling governor to performance by using the following script to set all CPUs to maximum performance mode: for CPUFREQ in /sys/devices/system/cpu/cpu*/cpufreq/scaling_governor; do [ -f $CPUFREQ ] || continue; echo -n performance > $CPUFREQ; done Verify that all CPU cores are set to maximum performance mode by issuing the following command: cat /sys/devices/system/cpu/cpu*/cpufreq/scaling_governor

Configuring Kernel sysctl Settings Set the kernel sysctl settings as follows: sysctl -w net.ipv4.tcp_mem="4194304 4194304 4194304" sysctl -w net.ipv4.tcp_wmem="4096 65536 4194304" sysctl -w net.ipv4.tcp_rmem="4096 87380 4194304" sysctl -w net.core.wmem_max=4194304 sysctl -w net.core.rmem_max=4194304 sysctl -w net.core.wmem_default=4194304 sysctl -w net.core.rmem_default=4194304 sysctl -w net.core.netdev_max_backlog=250000 sysctl -w net.ipv4.tcp_timestamps=0 sysctl -w net.ipv4.tcp_sack=1 sysctl -w net.ipv4.tcp_low_latency=1 sysctl -w net.ipv4.tcp_adv_win_scale=1 echo 0 > /proc/sys/vm/nr_hugepages

9iSER Configuration Configuring iSER on ESXi 6.7

196 AH0054602-00 M

Configuring IRQ Affinity Settings The following example sets CPU core 0, 1, 2, and 3 to interrupt request (IRQ) XX, YY, ZZ, and XYZ respectively. Perform these steps for each IRQ assigned to a port (default is eight queues per port). systemctl disable irqbalance systemctl stop irqbalance cat /proc/interrupts | grep qedr Shows IRQ assigned to each port queue echo 1 > /proc/irq/XX/smp_affinity_list echo 2 > /proc/irq/YY/smp_affinity_list echo 4 > /proc/irq/ZZ/smp_affinity_list echo 8 > /proc/irq/XYZ/smp_affinity_list

Configuring Block Device Staging Set the block device staging settings for each iSCSI device or target as follows: echo noop > /sys/block/sdd/queue/scheduler echo 2 > /sys/block/sdd/queue/nomerges echo 0 > /sys/block/sdd/queue/add_random echo 1 > /sys/block/sdd/queue/rq_affinity

Configuring iSER on ESXi 6.7 This section provides information for configuring iSER for VMware ESXi 6.7.

Before You Begin Before you configure iSER for ESXi 6.7, ensure that the following is complete:

The CNA package with NIC and RoCE drivers is installed on the ESXi 6.7 system and the devices are listed. To view RDMA devices, issue the following command:

esxcli rdma device list Name Driver State MTU Speed Paired Uplink Description ------- ------- ------ ---- ------- ------------- -------------------------------------- vmrdma0 qedrntv Active 1024 40 Gbps vmnic4 QLogic FastLinQ QL45xxx RDMA Interface vmrdma1 qedrntv Active 1024 40 Gbps vmnic5 QLogic FastLinQ QL45xxx RDMA Interface [root@localhost:~] esxcfg-vmknic -l Interface Port Group/DVPort/Opaque Network IP Family IP Address Netmask Broadcast MAC Address MTU TSO MSS Enabled Type NetStack vmk0 Management Network IPv4 172.28.12.94 255.255.240.0 172.28.15.255 e0:db:55:0c:5f:94 1500 65535 true DHCP defaultTcpipStack

9iSER Configuration Configuring iSER on ESXi 6.7

197 AH0054602-00 M

vmk0 Management Network IPv6 fe80::e2db:55ff:fe0c:5f94 64 e0:db:55:0c:5f:94 1500 65535 true STATIC, PREFERRED defaultTcpipStack

The iSER target is configured to communicate with the iSER initiator.

Configuring iSER for ESXi 6.7 To configure iSER for ESXi 6.7: 1. Add iSER devices by issuing the following commands: esxcli rdma iser add esxcli iscsi adapter list Adapter Driver State UID Description ------- ------ ------- ------------- ------------------------------------- vmhba64 iser unbound iscsi.vmhba64 VMware iSCSI over RDMA (iSER) Adapter vmhba65 iser unbound iscsi.vmhba65 VMware iSCSI over RDMA (iSER) Adapter

2. Disable the firewall as follows. esxcli network firewall set --enabled=false esxcli network firewall unload vsish -e set /system/modules/iscsi_trans/loglevels/iscsitrans 0 vsish -e set /system/modules/iser/loglevels/debug 4

3. Create a standard vSwitch VMkernel port group and assign the IP: esxcli network vswitch standard add -v vSwitch_iser1 esxcfg-nics -l Name PCI Driver Link Speed Duplex MAC Address MTU Description vmnic0 0000:01:00.0 ntg3 Up 1000Mbps Full e0:db:55:0c:5f:94 1500 Broadcom Corporation NetXtreme BCM5720 Gigabit Ethernet vmnic1 0000:01:00.1 ntg3 Down 0Mbps Half e0:db:55:0c:5f:95 1500 Broadcom Corporation NetXtreme BCM5720 Gigabit Ethernet vmnic2 0000:02:00.0 ntg3 Down 0Mbps Half e0:db:55:0c:5f:96 1500 Broadcom Corporation NetXtreme BCM5720 Gigabit Ethernet vmnic3 0000:02:00.1 ntg3 Down 0Mbps Half e0:db:55:0c:5f:97 1500 Broadcom Corporation NetXtreme BCM5720 Gigabit Ethernet vmnic4 0000:42:00.0 qedentv Up 40000Mbps Full 00:0e:1e:d5:f6:a2 1500 QLogic Corp. QLogic FastLinQ QL41xxx 10/25/40/50/100 GbE Ethernet Adapter vmnic5 0000:42:00.1 qedentv Up 40000Mbps Full 00:0e:1e:d5:f6:a3 1500 QLogic Corp. QLogic FastLinQ QL41xxx 10/25/40/50/100 GbE Ethernet Adapter

esxcli network vswitch standard uplink add -u vmnic5 -v vSwitch_iser1 esxcli network vswitch standard portgroup add -p "rdma_group1" -v vSwitch_iser1 esxcli network ip interface add -i vmk1 -p "rdma_group1" esxcli network ip interface ipv4 set -i vmk1 -I 192.168.10.100 -N 255.255.255.0 -t static esxcfg-vswitch -p "rdma_group1" -v 4095 vSwitch_iser1

9iSER Configuration Configuring iSER on ESXi 6.7

198 AH0054602-00 M

esxcli iscsi networkportal add -A vmhba67 -n vmk1 esxcli iscsi networkportal list esxcli iscsi adapter get -A vmhba65 vmhba65 Name: iqn.1998-01.com.vmware:localhost.punelab.qlogic.com qlogic.org qlogic.com mv.qlogic.com:1846573170:65 Alias: iser-vmnic5 Vendor: VMware Model: VMware iSCSI over RDMA (iSER) Adapter Description: VMware iSCSI over RDMA (iSER) Adapter Serial Number: vmnic5 Hardware Version: Asic Version: Firmware Version: Option Rom Version: Driver Name: iser-vmnic5 Driver Version: TCP Protocol Supported: false Bidirectional Transfers Supported: false Maximum Cdb Length: 64 Can Be NIC: true Is NIC: true Is Initiator: true Is Target: false Using TCP Offload Engine: true Using ISCSI Offload Engine: true

4. Add the target to the iSER initiator as follows: esxcli iscsi adapter target list esxcli iscsi adapter discovery sendtarget add -A vmhba65 -a 192.168.10.11 esxcli iscsi adapter target list Adapter Target Alias Discovery Method Last Error ------- ------------------------ ----- ---------------- ---------- vmhba65 iqn.2015-06.test.target1 SENDTARGETS No Error esxcli storage core adapter rescan --adapter vmhba65

5. List the attached target as follows: esxcfg-scsidevs -l mpx.vmhba0:C0:T4:L0 Device Type: CD-ROM Size: 0 MB Display Name: Local TSSTcorp CD-ROM (mpx.vmhba0:C0:T4:L0) Multipath Plugin: NMP

9iSER Configuration Configuring iSER on ESXi 6.7

199 AH0054602-00 M

Console Device: /vmfs/devices/cdrom/mpx.vmhba0:C0:T4:L0 Devfs Path: /vmfs/devices/cdrom/mpx.vmhba0:C0:T4:L0 Vendor: TSSTcorp Model: DVD-ROM SN-108BB Revis: D150 SCSI Level: 5 Is Pseudo: false Status: on Is RDM Capable: false Is Removable: true Is Local: true Is SSD: false Other Names: vml.0005000000766d686261303a343a30 VAAI Status: unsupported naa.6001405e81ae36b771c418b89c85dae0 Device Type: Direct-Access Size: 512 MB Display Name: LIO-ORG iSCSI Disk (naa.6001405e81ae36b771c418b89c85dae0) Multipath Plugin: NMP Console Device: /vmfs/devices/disks/naa.6001405e81ae36b771c418b89c85dae0 Devfs Path: /vmfs/devices/disks/naa.6001405e81ae36b771c418b89c85dae0 Vendor: LIO-ORG Model: ram1 Revis: 4.0 SCSI Level: 5 Is Pseudo: false Status: degraded Is RDM Capable: true Is Removable: false Is Local: false Is SSD: false Other Names: vml.02000000006001405e81ae36b771c418b89c85dae072616d312020 VAAI Status: supported naa.690b11c0159d050018255e2d1d59b612

200 AH0054602-00 M

10 iSCSI Configuration

This chapter provides the following iSCSI configuration information:

iSCSI Boot

iSCSI Offload in Windows Server on page 200

iSCSI Offload in Linux Environments on page 209

iSCSI Boot Marvell 4xxxx Series gigabit Ethernet (GbE) adapters support iSCSI boot to enable network boot of operating systems to diskless systems. iSCSI boot allows a Windows, Linux, or VMware operating system to boot from an iSCSI target machine located remotely over a standard IP network.

Jumbo frames with iSCSI boot are supported only on Windows OSs, when the adapter is used as either an NDIS or HBA offload device.

For iSCSI boot from SAN information, see Chapter 6 Boot from SAN Configuration.

iSCSI Offload in Windows Server iSCSI offload is a technology that offloads iSCSI protocol processing overhead from host processors to the iSCSI HBA. iSCSI offload increases network performance and throughput while helping to optimize server processor use. This section covers how to configure the Windows iSCSI offload feature for the Marvell 41xxx Series Adapters.

NOTE Some iSCSI features may not be fully enabled in the current release. For details, refer to Appendix D Feature Constraints. To enable iSCSI-Offload mode, see the Application Note, Enabling Storage Offloads on Dell and Marvell FastLinQ 41000 Series Adapters at https://www.marvell.com/documents/5aa5otcbkr0im3ynera3/.

10iSCSI Configuration iSCSI Offload in Windows Server

201 AH0054602-00 M

With the proper iSCSI offload licensing, you can configure your iSCSI-capable 41xxx Series Adapter to offload iSCSI processing from the host processor. The following sections describe how to enable the system to take advantage of Marvells iSCSI offload feature:

Installing Marvell Drivers

Installing the Microsoft iSCSI Initiator

Configuring Microsoft Initiator to Use Marvells iSCSI Offload

iSCSI Offload FAQs

Windows Server 2012 R2, 2016, and 2019 iSCSI Boot Installation

iSCSI Crash Dump

Installing Marvell Drivers Install the Windows drivers as described in Installing Windows Driver Software on page 18.

Installing the Microsoft iSCSI Initiator Launch the Microsoft iSCSI initiator applet. At the first launch, the system prompts for an automatic service start. Confirm the selection for the applet to launch.

Configuring Microsoft Initiator to Use Marvells iSCSI Offload After the IP address is configured for the iSCSI adapter, you must use Microsoft Initiator to configure and add a connection to the iSCSI target using the Marvell FastLinQ iSCSI adapter. For more details on Microsoft Initiator, see the Microsoft user guide.

To configure Microsoft Initiator: 1. Open Microsoft Initiator.

2. To configure the initiator IQN name according to your setup, follow these steps:

a. On the iSCSI Initiator Properties, click the Configuration tab.

b. On the Configuration page (Figure 10-1), click Change next to To modify the initiator name.

10iSCSI Configuration iSCSI Offload in Windows Server

202 AH0054602-00 M

Figure 10-1. iSCSI Initiator Properties, Configuration Page

c. In the iSCSI Initiator Name dialog box, type the new initiator IQN name, and then click OK. (Figure 10-2)

Figure 10-2. iSCSI Initiator Node Name Change

3. On the iSCSI Initiator Properties, click the Discovery tab.

10iSCSI Configuration iSCSI Offload in Windows Server

203 AH0054602-00 M

4. On the Discovery page (Figure 10-3) under Target portals, click Discover Portal.

Figure 10-3. iSCSI InitiatorDiscover Target Portal

5. In the Discover Target Portal dialog box (Figure 10-4):

a. In the IP address or DNS name box, type the IP address of the target.

b. Click Advanced.

10iSCSI Configuration iSCSI Offload in Windows Server

204 AH0054602-00 M

Figure 10-4. Target Portal IP Address

6. In the Advanced Settings dialog box (Figure 10-5), complete the following under Connect using:

a. For Local adapter, select the QLogic Adapter . b. For Initiator IP, select the adapter IP address.

c. Click OK.

10iSCSI Configuration iSCSI Offload in Windows Server

205 AH0054602-00 M

Figure 10-5. Selecting the Initiator IP Address

7. On the iSCSI Initiator Properties, Discovery page, click OK.

10iSCSI Configuration iSCSI Offload in Windows Server

206 AH0054602-00 M

8. Click the Targets tab, and then on the Targets page (Figure 10-6), click Connect.

Figure 10-6. Connecting to the iSCSI Target

10iSCSI Configuration iSCSI Offload in Windows Server

207 AH0054602-00 M

9. On the Connect To Target dialog box (Figure 10-7), click Advanced.

Figure 10-7. Connect To Target Dialog Box

10. In the Local Adapter dialog box, select the QLogic Adapter, and then click OK.

11. Click OK again to close Microsoft Initiator.

12. To format the iSCSI partition, use Disk Manager.

iSCSI Offload FAQs Some of the frequently asked questions about iSCSI offload include:

Question: How do I assign an IP address for iSCSI offload? Answer: Use the Configurations page in QConvergeConsole GUI.

NOTE Some limitations of the teaming functionality include: Teaming does not support iSCSI adapters. Teaming does not support NDIS adapters that are in the boot path. Teaming supports NDIS adapters that are not in the iSCSI boot

path, but only for the switch-independent NIC team type. Switch dependent teaming (IEEE 802.3ad LACP and

Generic/Static Link Aggregation (Trunking) cannot use a switch independent partitioned virtual adapter. IEEE standards require Switch Dependent Teaming (IEEE 802.3ad LACP and Generic/Static Link Aggregation (Trunking)) mode to work per the entire port instead of just the MAC address (fraction of a port) granularity.

Microsoft recommends using their in-OS NIC teaming service instead of any adapter vendor-proprietary NIC teaming driver on Windows Server 2012 and later.

10iSCSI Configuration iSCSI Offload in Windows Server

208 AH0054602-00 M

Question: What tools should I use to create the connection to the target? Answer: Use Microsoft iSCSI Software Initiator (version 2.08 or later).

Question: How do I know that the connection is offloaded? Answer: Use Microsoft iSCSI Software Initiator. From a command line, type

oiscsicli sessionlist. From Initiator Name, an iSCSI offloaded connection will display an entry beginning with B06BDRV. A non-offloaded connection displays an entry beginning with Root.

Question: What configurations should be avoided? Answer: The IP address should not be the same as the LAN.

Windows Server 2012 R2, 2016, and 2019 iSCSI Boot Installation

Windows Server 2012 R2, Windows Server 2016, and Windows Server 2019 support booting and installing in either the offload or non-offload paths. Marvell requires that you use a slipstream DVD with the latest Marvell drivers injected. See Injecting (Slipstreaming) Adapter Drivers into Windows Image Files on page 122.

The following procedure prepares the image for installation and booting in either the offload or non-offload path.

To set up Windows Server 2012 R2/2016/2019 iSCSI boot: 1. Remove any local hard drives on the system to be booted (remote system).

2. Prepare the Windows OS installation media by following the slipstreaming steps in Injecting (Slipstreaming) Adapter Drivers into Windows Image Files on page 122.

3. Load the latest Marvell iSCSI boot images into the NVRAM of the adapter.

4. Configure the iSCSI target to allow a connection from the remote device. Ensure that the target has sufficient disk space to hold the new OS installation.

5. Configure the UEFI HII to set the iSCSI boot type (offload or non-offload), correct initiator, and target parameters for iSCSI boot.

6. Save the settings and reboot the system. The remote system should connect to the iSCSI target and then boot from the DVD-ROM device.

7. Boot from DVD and begin installation.

8. Follow the on-screen instructions.

At the window that shows the list of disks available for the installation, the iSCSI target disk should be visible. This target is a disk connected through the iSCSI boot protocol and located in the remote iSCSI target.

10iSCSI Configuration iSCSI Offload in Linux Environments

209 AH0054602-00 M

9. To proceed with Windows Server 2012 R2/2016 installation, click Next, and then follow the on-screen instructions. The server will undergo a reboot multiple times as part of the installation process.

10. After the server boots to the OS, you should run the driver installer to complete the Marvell drivers and application installation.

iSCSI Crash Dump Crash dump functionality is supported for both non-offload and offload iSCSI boot for the 41xxx Series Adapters. No additional configurations are required to configure iSCSI crash dump generation.

iSCSI Offload in Linux Environments The Marvell FastLinQ 41xxx iSCSI software consists of a single kernel module called qedi.ko (qedi). The qedi module is dependent on additional parts of the Linux kernel for specific functionality:

qed.ko is the Linux eCore kernel module used for common Marvell FastLinQ 41xxx hardware initialization routines.

scsi_transport_iscsi.ko is the Linux iSCSI transport library used for upcall and downcall for session management.

libiscsi.ko is the Linux iSCSI library function needed for protocol data unit (PDU) and task processing, as well as session memory management.

iscsi_boot_sysfs.ko is the Linux iSCSI sysfs interface that provides helpers to export iSCSI boot information.

uio.ko is the Linux Userspace I/O interface, used for light L2 memory mapping for iscsiuio.

These modules must be loaded before qedi can be functional. Otherwise, you might encounter an unresolved symbol error. If the qedi module is installed in the distribution update path, the requisite is automatically loaded by modprobe.

This section provides the following information about iSCSI offload in Linux:

Differences from bnx2i

Configuring qedi.ko

Verifying iSCSI Interfaces in Linux

10iSCSI Configuration iSCSI Offload in Linux Environments

210 AH0054602-00 M

Differences from bnx2i Some key differences exist between qedithe driver for the Marvell FastLinQ 41xxx Series Adapter (iSCSI)and the previous Marvell iSCSI offload driverbnx2i for the Marvell 8400 Series Adapters. Some of these differences include:

qedi directly binds to a PCI function exposed by the CNA.

qedi does not sit on top of the net_device.

qedi is not dependent on a network driver such as bnx2x and cnic.

qedi is not dependent on cnic, but it has dependency on qed.

qedi is responsible for exporting boot information in sysfs using iscsi_boot_sysfs.ko, whereas bnx2i boot from SAN relies on the iscsi_ibft.ko module for exporting boot information.

Configuring qedi.ko The qedi driver automatically binds to the exposed iSCSI functions of the CNA, and the target discovery and binding is done through the Open-iSCSI tools. This functionality and operation is similar to that of the bnx2i driver.

To load the qedi.ko kernel module, issue the following commands: # modprobe qed # modprobe libiscsi # modprobe uio # modprobe iscsi_boot_sysfs # modprobe qedi

Verifying iSCSI Interfaces in Linux After installing and loading the qedi kernel module, you must verify that the iSCSI interfaces were detected correctly.

To verify iSCSI interfaces in Linux: 1. To verify that the qedi and associated kernel modules are actively loaded,

issue the following command: # lsmod | grep qedi qedi 114578 2 qed 697989 1 qedi uio 19259 4 cnic,qedi libiscsi 57233 2 qedi,bnx2i scsi_transport_iscsi 99909 5 qedi,bnx2i,libiscsi

10iSCSI Configuration iSCSI Offload in Linux Environments

211 AH0054602-00 M

iscsi_boot_sysfs 16000 1 qedi 2. To verify that the iSCSI interfaces were detected properly, issue the

following command. In this example, two iSCSI CNA devices are detected with SCSI host numbers 4 and 5.

# dmesg | grep qedi [0000:00:00.0]:[qedi_init:3696]: QLogic iSCSI Offload Driver v8.15.6.0. .... [0000:42:00.4]:[__qedi_probe:3563]:59: QLogic FastLinQ iSCSI Module qedi 8.15.6.0, FW 8.15.3.0 .... [0000:42:00.4]:[qedi_link_update:928]:59: Link Up event. .... [0000:42:00.5]:[__qedi_probe:3563]:60: QLogic FastLinQ iSCSI Module qedi 8.15.6.0, FW 8.15.3.0 .... [0000:42:00.5]:[qedi_link_update:928]:59: Link Up event

3. Use Open-iSCSI tools to verify that the IP is configured properly. Issue the following command:

# iscsiadm -m iface | grep qedi qedi.00:0e:1e:c4:e1:6d qedi,00:0e:1e:c4:e1:6d,192.168.101.227, ,iqn.1994-05.com.redhat:534ca9b6adf qedi.00:0e:1e:c4:e1:6c qedi,00:0e:1e:c4:e1:6c,192.168.25.91, ,iqn.1994-05.com.redhat:534ca9b6adf

4. To ensure that the iscsiuio service is running, issue the following command: # systemctl status iscsiuio.service iscsiuio.service - iSCSI UserSpace I/O driver Loaded: loaded (/usr/lib/systemd/system/iscsiuio.service; disabled; vendor preset: disabled) Active: active (running) since Fri 2017-01-27 16:33:58 IST; 6 days ago Docs: man:iscsiuio(8) Process: 3745 ExecStart=/usr/sbin/iscsiuio (code=exited, status=0/SUCCESS) Main PID: 3747 (iscsiuio) CGroup: /system.slice/iscsiuio.service !--3747 /usr/sbin/iscsiuio Jan 27 16:33:58 localhost.localdomain systemd[1]: Starting iSCSI UserSpace I/O driver... Jan 27 16:33:58 localhost.localdomain systemd[1]: Started iSCSI UserSpace I/O driver.

5. To discover the iSCSI target, issue the iscsiadm command: #iscsiadm -m discovery -t st -p 192.168.25.100 -I qedi.00:0e:1e:c4:e1:6c 192.168.25.100:3260,1 iqn.2003- 04.com.sanblaze:virtualun.virtualun.target-05000007 192.168.25.100:3260,1 iqn.2003-04.com.sanblaze:virtualun.virtualun.target-05000012

10iSCSI Configuration iSCSI Offload in Linux Environments

212 AH0054602-00 M

192.168.25.100:3260,1 iqn.2003-04.com.sanblaze:virtualun.virtualun.target-0500000c 192.168.25.100:3260,1 iqn.2003- 04.com.sanblaze:virtualun.virtualun.target-05000001 192.168.25.100:3260,1 iqn.2003-04.com.sanblaze:virtualun.virtualun.target-05000002

6. Log into the iSCSI target using the IQN obtained in Step 5. To initiate the login procedure, issue the following command (where the last character in the command is a lowercase letter L):

#iscsiadm -m node -p 192.168.25.100 -T iqn.2003-04.com.sanblaze:virtualun.virtualun.target-0000007 -l Logging in to [iface: qedi.00:0e:1e:c4:e1:6c, target:iqn.2003-04.com.sanblaze:virtualun.virtualun.target-05000007, portal:192.168.25.100,3260] (multiple) Login to [iface: qedi.00:0e:1e:c4:e1:6c, target:iqn.2003- 04.com.sanblaze:virtualun.virtualun.target-05000007, portal:192.168.25.100,3260] successful.

7. To verify that the iSCSI session was created, issue the following command: # iscsiadm -m session qedi: [297] 192.168.25.100:3260,1 iqn.2003-04.com.sanblaze:virtualun.virtualun.target-05000007 (non-flash)

8. To check for iSCSI devices, issue the iscsiadm command: # iscsiadm -m session -P3 ... ************************ Attached SCSI devices: ************************ Host Number: 59 State: running scsi59 Channel 00 Id 0 Lun: 0 Attached scsi disk sdb State: running scsi59 Channel 00 Id 0 Lun: 1 Attached scsi disk sdc State: running scsi59 Channel 00 Id 0 Lun: 2 Attached scsi disk sdd State: running scsi59 Channel 00 Id 0 Lun: 3 Attached scsi disk sde State: running scsi59 Channel 00 Id 0 Lun: 4 Attached scsi disk sdf State: running

For advanced target configurations, refer to the Open-iSCSI README at:

https://github.com/open-iscsi/open-iscsi/blob/master/README

213 AH0054602-00 M

11 FCoE Configuration

This chapter provides the following Fibre Channel over Ethernet (FCoE) configuration information:

Configuring Linux FCoE Offload on page 213

For FCoE boot from SAN information, see Chapter 6 Boot from SAN Configuration.

Configuring Linux FCoE Offload The Marvell FastLinQ 41xxx Series Adapter FCoE software consists of a single kernel module called qedf.ko (qedf). The qedf module is dependent on additional parts of the Linux kernel for specific functionality:

qed.ko is the Linux eCore kernel module used for common Marvell FastLinQ 41xxx hardware initialization routines.

libfcoe.ko is the Linux FCoE kernel library needed to conduct FCoE forwarder (FCF) solicitation and FCoE initialization protocol (FIP) fabric login (FLOGI).

libfc.ko is the Linux FC kernel library needed for several functions, including:

Name server login and registration rport session management

scsi_transport_fc.ko is the Linux FC SCSI transport library used for remote port and SCSI target management.

NOTE FCoE offload is supported on all 41xxx Series Adapters. Some FCoE features may not be fully enabled in the current release. For details, refer to Appendix D Feature Constraints. To enable iSCSI-Offload mode, see the Application Note, Enabling Storage Offloads on Dell and Marvell FastLinQ 41000 Series Adapters at https://www.marvell.com/documents/5aa5otcbkr0im3ynera3/.

11FCoE Configuration Configuring Linux FCoE Offload

214 AH0054602-00 M

These modules must be loaded before qedf can be functional, otherwise errors such as unresolved symbol can result. If the qedf module is installed in the distribution update path, the requisite modules are automatically loaded by modprobe. Marvell FastLinQ 41xxx Series Adapters support FCoE offload.

This section provides the following information about FCoE offload in Linux:

Differences Between qedf and bnx2fc

Configuring qedf.ko

Verifying FCoE Devices in Linux

Differences Between qedf and bnx2fc Significant differences exist between qedfthe driver for the Marvell FastLinQ 41xxx 10/25GbE Controller (FCoE)and the previous Marvell FCoE offload driver, bnx2fc. Differences include:

qedf directly binds to a PCI function exposed by the CNA.

qedf does not need the open-fcoe user space tools (fipvlan, fcoemon, fcoeadm) to initiate discovery.

qedf issues FIP vLAN requests directly and does not need the fipvlan utility.

qedf does not need an FCoE interface created by fipvlan for fcoemon.

qedf does not sit on top of the net_device.

qedf is not dependent on network drivers (such as bnx2x and cnic).

qedf will automatically initiate FCoE discovery on link up (because it is not dependent on fipvlan or fcoemon for FCoE interface creation).

Configuring qedf.ko No explicit configuration is required for qedf.ko. The driver automatically binds to the exposed FCoE functions of the CNA and begins discovery. This functionality is similar to the functionality and operation of the Marvell FC driver, qla2xx, as opposed to the older bnx2fc driver.

NOTE FCoE interfaces no longer sit on top of the network interface. The qedf driver automatically creates FCoE interfaces that are separate from the network interface. Thus, FCoE interfaces do not show up in the FCoE interface dialog box in the installer. Instead, the disks show up automatically as SCSI disks, similar to the way Fibre Channel drivers work.

11FCoE Configuration Configuring Linux FCoE Offload

215 AH0054602-00 M

The load qedf.ko kernel module performs the following: # modprobe qed # modprobe libfcoe # modprobe qedf

Verifying FCoE Devices in Linux Follow these steps to verify that the FCoE devices were detected correctly after installing and loading the qedf kernel module.

To verify FCoE devices in Linux: 1. Check lsmod to verify that the qedf and associated kernel modules were

loaded: # lsmod | grep qedf 69632 1 qedf libfc 143360 2 qedf,libfcoe scsi_transport_fc 65536 2 qedf,libfc qed 806912 1 qedf scsi_mod 262144 14 sg,hpsa,qedf,scsi_dh_alua,scsi_dh_rdac,dm_multipath, scsi_transport_fc,scsi_transport_sas,libfc,scsi_transport_iscsi,scsi_dh_emc, libata,sd_mod,sr_mod

2. Check dmesg to verify that the FCoE devices were detected properly. In this example, the two detected FCoE CNA devices are SCSI host numbers 4 and 5.

# dmesg | grep qedf [ 235.321185] [0000:00:00.0]: [qedf_init:3728]: QLogic FCoE Offload Driver v8.18.8.0. .... [ 235.322253] [0000:21:00.2]: [__qedf_probe:3142]:4: QLogic FastLinQ FCoE Module qedf 8.18.8.0, FW 8.18.10.0 [ 235.606443] scsi host4: qedf .... [ 235.624337] [0000:21:00.3]: [__qedf_probe:3142]:5: QLogic FastLinQ FCoE Module qedf 8.18.8.0, FW 8.18.10.0 [ 235.886681] scsi host5: qedf ....

NOTE For more information on FastLinQ driver installation, see Chapter 3 Driver Installation.

11FCoE Configuration Configuring Linux FCoE Offload

216 AH0054602-00 M

[ 243.991851] [0000:21:00.3]: [qedf_link_update:489]:5: LINK UP (40 GB/s). 3. Check for discovered FCoE devices using the lsscsi or lsblk -S

commands. An example of each command follows. # lsscsi [0:2:0:0] disk DELL PERC H700 2.10 /dev/sda [2:0:0:0] cd/dvd TEAC DVD-ROM DV-28SW R.2A /dev/sr0 [151:0:0:0] disk HP P2000G3 FC/iSCSI T252 /dev/sdb [151:0:0:1] disk HP P2000G3 FC/iSCSI T252 /dev/sdc [151:0:0:2] disk HP P2000G3 FC/iSCSI T252 /dev/sdd [151:0:0:3] disk HP P2000G3 FC/iSCSI T252 /dev/sde [151:0:0:4] disk HP P2000G3 FC/iSCSI T252 /dev/sdf

# lsblk -S NAME HCTL TYPE VENDOR MODEL REV TRAN sdb 5:0:0:0 disk SANBlaze VLUN P2T1L0 V7.3 fc sdc 5:0:0:1 disk SANBlaze VLUN P2T1L1 V7.3 fc sdd 5:0:0:2 disk SANBlaze VLUN P2T1L2 V7.3 fc sde 5:0:0:3 disk SANBlaze VLUN P2T1L3 V7.3 fc sdf 5:0:0:4 disk SANBlaze VLUN P2T1L4 V7.3 fc sdg 5:0:0:5 disk SANBlaze VLUN P2T1L5 V7.3 fc sdh 5:0:0:6 disk SANBlaze VLUN P2T1L6 V7.3 fc sdi 5:0:0:7 disk SANBlaze VLUN P2T1L7 V7.3 fc sdj 5:0:0:8 disk SANBlaze VLUN P2T1L8 V7.3 fc sdk 5:0:0:9 disk SANBlaze VLUN P2T1L9 V7.3 fc

Configuration information for the host is located in /sys/class/fc_host/hostX, where X is the number of the SCSI host. In the preceding example, X is 4. The hostX file contains attributes for the FCoE function, such as worldwide port name and fabric ID.

217 AH0054602-00 M

12 SR-IOV Configuration

Single root input/output virtualization (SR-IOV) is a specification by the PCI SIG that enables a single PCI Express (PCIe) device to appear as multiple, separate physical PCIe devices. SR-IOV permits isolation of PCIe resources for performance, interoperability, and manageability.

This chapter provides instructions for:

Configuring SR-IOV on Windows

Configuring SR-IOV on Linux on page 224

Configuring SR-IOV on VMware on page 230

Configuring SR-IOV on Windows To configure SR-IOV on Windows: 1. Access the server BIOS System Setup, and then click System BIOS

Settings.

2. On the System BIOS Settings page, click Integrated Devices.

3. On the Integrated Devices page (Figure 12-1):

a. Set the SR-IOV Global Enable option to Enabled.

b. Click Back.

NOTE Some SR-IOV features may not be fully enabled in the current release.

12SR-IOV Configuration Configuring SR-IOV on Windows

218 AH0054602-00 M

Figure 12-1. System Setup for SR-IOV: Integrated Devices

4. On the Main Configuration Page for the selected adapter, click Device Level Configuration.

5. On the Main Configuration Page - Device Level Configuration (Figure 12-2):

a. Set the Virtualization Mode to SR-IOV, or NPAR+SR-IOV if you are using NPAR mode.

b. Click Back.

Figure 12-2. System Setup for SR-IOV: Device Level Configuration

6. On the Main Configuration Page, click Finish.

7. In the Warning - Saving Changes message box, click Yes to save the configuration.

8. In the Success - Saving Changes message box, click OK.

12SR-IOV Configuration Configuring SR-IOV on Windows

219 AH0054602-00 M

9. To enable SR-IOV on the miniport adapter:

a. Access Device Manager.

b. Open the miniport adapter properties, and then click the Advanced tab.

c. On the Advanced properties page (Figure 12-3) under Property, select SR-IOV, and then set the value to Enabled.

d. Click OK.

Figure 12-3. Adapter Properties, Advanced: Enabling SR-IOV

10. To create a Virtual Machine Switch (vSwitch) with SR-IOV (Figure 12-4 on page 220):

a. Launch the Hyper-V Manager.

b. Select Virtual Switch Manager. c. In the Name box, type a name for the virtual switch.

d. Under Connection type, select External network.

e. Select the Enable single-root I/O virtualization (SR-IOV) check box, and then click Apply.

12SR-IOV Configuration Configuring SR-IOV on Windows

220 AH0054602-00 M

Figure 12-4. Virtual Switch Manager: Enabling SR-IOV

f. The Apply Networking Changes message box advises you that Pending changes may disrupt network connectivity. To save your changes and continue, click Yes.

NOTE Be sure to enable SR-IOV when you create the vSwitch. This option is unavailable after the vSwitch is created.

12SR-IOV Configuration Configuring SR-IOV on Windows

221 AH0054602-00 M

11. To get the virtual machine switch capability, issue the following Windows PowerShell command: PS C:\Users\Administrator> Get-VMSwitch -Name SR-IOV_vSwitch | fl Output of the Get-VMSwitch command includes the following SR-IOV capabilities: IovVirtualFunctionCount : 80 IovVirtualFunctionsInUse : 1

12. To create a virtual machine (VM) and export the virtual function (VF) in the VM:

a. Create a virtual machine.

b. Add the VMNetworkadapter to the virtual machine.

c. Assign a virtual switch to the VMNetworkadapter.

d. In the Settings for VM dialog box (Figure 12-5), Hardware Acceleration page, under Single-root I/O virtualization, select the Enable SR-IOV check box, and then click OK.

NOTE After the virtual adapter connection is created, the SR-IOV setting can be enabled or disabled at any time (even while traffic is running).

12SR-IOV Configuration Configuring SR-IOV on Windows

222 AH0054602-00 M

Figure 12-5. Settings for VM: Enabling SR-IOV

13. Install the Marvell drivers for the adapters detected in the VM. Use the latest drivers available from your vendor for your host OS (do not use inbox drivers).

NOTE Be sure to use the same driver package on both the VM and the host system. For example, use the same qeVBD and qeND driver version on the Windows VM and in the Windows Hyper-V host.

12SR-IOV Configuration Configuring SR-IOV on Windows

223 AH0054602-00 M

After installing the drivers, the adapter is listed in the VM. Figure 12-6 shows an example.

Figure 12-6. Device Manager: VM with QLogic Adapter

14. To view the SR-IOV VF details, issue the following Windows PowerShell command: PS C:\Users\Administrator> Get-NetadapterSriovVf Figure 12-7 shows example output.

Figure 12-7. Windows PowerShell Command: Get-NetadapterSriovVf

12SR-IOV Configuration Configuring SR-IOV on Linux

224 AH0054602-00 M

Configuring SR-IOV on Linux To configure SR-IOV on Linux: 1. Access the server BIOS System Setup, and then click System BIOS

Settings.

2. On the System BIOS Settings page, click Integrated Devices.

3. On the System Integrated Devices page (see Figure 12-1 on page 218):

a. Set the SR-IOV Global Enable option to Enabled.

b. Click Back.

4. On the System BIOS Settings page, click Processor Settings.

5. On the Processor Settings (Figure 12-8) page:

a. Set the Virtualization Technology option to Enabled.

b. Click Back.

Figure 12-8. System Setup: Processor Settings for SR-IOV

6. On the System Setup page, select Device Settings.

12SR-IOV Configuration Configuring SR-IOV on Linux

225 AH0054602-00 M

7. On the Device Settings page, select Port 1 for the Marvell adapter.

8. On the Device Level Configuration page (Figure 12-9):

a. Set the Virtualization Mode to SR-IOV.

b. Click Back.

Figure 12-9. System Setup for SR-IOV: Integrated Devices

9. On the Main Configuration Page, click Finish, save your settings, and then reboot the system.

10. To enable and verify virtualization:

a. Open the grub.conf file and configure the iommu parameter as shown in Figure 12-10. (For details, see Enabling IOMMU for SR-IOV in UEFI-based Linux OS Installations on page 229.)

For Intel-based systems, add intel_iommu=on. For AMD-based systems, add amd_iommu=on.

12SR-IOV Configuration Configuring SR-IOV on Linux

226 AH0054602-00 M

Figure 12-10. Editing the grub.conf File for SR-IOV

b. Save the grub.conf file and then reboot the system.

c. To verify that the changes are in effect, issue the following command: dmesg | grep -i iommu

A successful inputoutput memory management unit (IOMMU) command output should show, for example: Intel-IOMMU: enabled

d. To view VF details (number of VFs and total VFs), issue the following command: find /sys/|grep -i sriov

11. For a specific port, enable a quantity of VFs.

a. Issue the following command to enable, for example, 8 VFs on PCI instance 04:00.0 (bus 4, device 0, function 0): [root@ah-rh68 ~]# echo 8 > /sys/devices/pci0000:00/0000:00:02.0/0000:04:00.0/ sriov_numvfs

12SR-IOV Configuration Configuring SR-IOV on Linux

227 AH0054602-00 M

b. Review the command output (Figure 12-11) to confirm that actual VFs were created on bus 4, device 2 (from the 0000:00:02.0 parameter), functions 0 through 7. Note that the actual device ID is different on the PFs (8070 in this example) versus the VFs (8090 in this example).

Figure 12-11. Command Output for sriov_numvfs

12. To view a list of all PF and VF interfaces, issue the following command: # ip link show | grep -i vf -b2 Figure 12-12 shows example output.

Figure 12-12. Command Output for ip link show Command

13. Assign and verify MAC addresses:

a. To assign a MAC address to the VF, issue the following command: ip link set vf mac

12SR-IOV Configuration Configuring SR-IOV on Linux

228 AH0054602-00 M

b. Ensure that the VF interface is up and running with the assigned MAC address.

14. Power off the VM and attach the VF. (Some OSs support hot-plugging of VFs to the VM.)

a. In the Virtual Machine dialog box (Figure 12-13), click Add Hardware.

Figure 12-13. RHEL68 Virtual Machine

b. In the left pane of the Add New Virtual Hardware dialog box (Figure 12-14), click PCI Host Device.

c. In the right pane, select a host device.

d. Click Finish.

12SR-IOV Configuration Configuring SR-IOV on Linux

229 AH0054602-00 M

Figure 12-14. Add New Virtual Hardware

15. Power on the VM, and then issue the following command: check lspci -vv|grep -I ether

16. Install the drivers for the adapters detected in the VM. Use the latest drivers available from your vendor for your host OS (do not use inbox drivers). The same driver version must be installed on the host and the VM.

17. As needed, add more VFs in the VM.

Enabling IOMMU for SR-IOV in UEFI-based Linux OS Installations

Follow the appropriate procedure for your Linux OS.

To enable IOMMU for SR-IOV on RHEL 6.x: In the /boot/efi/EFI/redhat/grub.conf file, locate the kernel line, and

then append the intel_iommu=on boot parameter.

To enable IOMMU for SR-IOV on RHEL 7.x and later: 1. In the /etc/default/grub file, locate GRUB_CMDLINE_LINUX, and then

append the intel_iommu=on boot parameter.

2. To update the grub configuration file, issue the following command: grub2-mkconfig -o /boot/efi/EFI/redhat/grub.cfg

NOTE For AMD systems, replace intel_iommu=on with amd_iommu=on.

12SR-IOV Configuration Configuring SR-IOV on VMware

230 AH0054602-00 M

To enable IOMMU for SR-IOV on SLES 12.x: 1. In the /etc/default/grub file, locate GRUB_CMDLINE_LINUX_DEFAULT,

and then append the intel_iommu=on boot parameter.

2. To update the grub configuration file, issue the following command: grub2-mkconfig -o /boot/grub2/grub.cfg

To enable IOMMU for SR-IOV on SLES 15.x and later: 1. In the /etc/default/grub file, locate GRUB_CMDLINE_LINUX_DEFAULT,

and then append the intel_iommu=on boot parameter.

2. To update the grub configuration file, issue the following command: grub2-mkconfig -o /boot/efi/EFI/sles/grub.cfg

Configuring SR-IOV on VMware To configure SR-IOV on VMware: 1. Access the server BIOS System Setup, and then click System BIOS

Settings.

2. On the System BIOS Settings page, click Integrated Devices.

3. On the Integrated Devices page (see Figure 12-1 on page 218):

a. Set the SR-IOV Global Enable option to Enabled.

b. Click Back.

4. In the System Setup window, click Device Settings.

5. On the Device Settings page, select a port for the 25G 41xxx Series Adapter.

6. On the Device Level Configuration page (see Figure 12-2 on page 218):

a. Set the Virtualization Mode to SR-IOV.

b. Click Back.

7. On the Main Configuration Page, click Finish.

8. Save the configuration settings and reboot the system.

12SR-IOV Configuration Configuring SR-IOV on VMware

231 AH0054602-00 M

9. To enable the needed quantity of VFs per port (in this example, 16 on each port of a dual-port adapter), issue the following command: "esxcfg-module -s "max_vfs=16,16" qedentv"

10. Reboot the host.

11. To verify that the changes are complete at the module level, issue the following command: "esxcfg-module -g qedentv" [root@localhost:~] esxcfg-module -g qedentv qedentv enabled = 1 options = 'max_vfs=16,16'

12. To verify if actual VFs were created, issue the lspci command as follows: [root@localhost:~] lspci | grep -i QLogic | grep -i 'ethernet\|network' | more 0000:05:00.0 Network controller: QLogic Corp. QLogic FastLinQ QL41xxx 10/25 GbE Ethernet Adapter [vmnic6] 0000:05:00.1 Network controller: QLogic Corp. QLogic FastLinQ QL41xxx 10/25 GbE Ethernet Adapter [vmnic7] 0000:05:02.0 Network controller: QLogic Corp. QLogic FastLinQ QL41xxx Series 10/25 GbE Controller (SR-IOV VF) [PF_0.5.0_VF_0] 0000:05:02.1 Network controller: QLogic Corp. QLogic FastLinQ QL41xxx Series 10/25 GbE Controller (SR-IOV VF) [PF_0.5.0_VF_1] 0000:05:02.2 Network controller: QLogic Corp. QLogic FastLinQ QL41xxx Series 10/25 GbE Controller (SR-IOV VF) [PF_0.5.0_VF_2] 0000:05:02.3 Network controller: QLogic Corp. QLogic FastLinQ QL41xxx Series 10/25 GbE Controller (SR-IOV VF) [PF_0.5.0_VF_3] . . . 0000:05:03.7 Network controller: QLogic Corp. QLogic FastLinQ QL41xxx Series 10/25 GbE Controller (SR-IOV VF) [PF_0.5.0_VF_15] 0000:05:0e.0 Network controller: QLogic Corp. QLogic FastLinQ QL41xxx Series 10/25 GbE Controller (SR-IOV VF) [PF_0.5.1_VF_0] 0000:05:0e.1 Network controller: QLogic Corp. QLogic FastLinQ QL41xxx Series 10/25 GbE Controller (SR-IOV VF) [PF_0.5.1_VF_1] 0000:05:0e.2 Network controller: QLogic Corp. QLogic FastLinQ QL41xxx Series 10/25 GbE Controller (SR-IOV VF) [PF_0.5.1_VF_2]

NOTE Each Ethernet function of the 41xxx Series Adapter must have its own entry.

12SR-IOV Configuration Configuring SR-IOV on VMware

232 AH0054602-00 M

0000:05:0e.3 Network controller: QLogic Corp. QLogic FastLinQ QL41xxx Series 10/25 GbE Controller (SR-IOV VF) [PF_0.5.1_VF_3] . . . 0000:05:0f.6 Network controller: QLogic Corp. QLogic FastLinQ QL41xxx Series 10/25 GbE Controller (SR-IOV VF) [PF_0.5.1_VF_14] 0000:05:0f.7 Network controller: QLogic Corp. QLogic FastLinQ QL41xxx Series 10/25 GbE Controller (SR-IOV VF) [PF_0.5.1_VF_15]

13. Attach VFs to the VM as follows:

a. Power off the VM and attach the VF. (Some OSs support hot-plugging of VFs to the VM.)

b. Add a host to a VMware vCenter Server Virtual Appliance (vCSA).

c. Click Edit Settings of the VM.

14. Complete the Edit Settings dialog box (Figure 12-15) as follows:

a. In the New Device box, select Network, and then click Add.

b. For Adapter Type, select SR-IOV Passthrough.

c. For Physical Function, select the Marvell VF.

d. To save your configuration changes and close this dialog box, click OK.

12SR-IOV Configuration Configuring SR-IOV on VMware

233 AH0054602-00 M

Figure 12-15. VMware Host Edit Settings

15. To validate the VFs per port, issue the esxcli command as follows: [root@localhost:~] esxcli network sriovnic vf list -n vmnic6 VF ID Active PCI Address Owner World ID ----- ------ ----------- -------------- 0 true 005:02.0 60591 1 true 005:02.1 60591

12SR-IOV Configuration Configuring SR-IOV on VMware

234 AH0054602-00 M

2 false 005:02.2 - 3 false 005:02.3 - 4 false 005:02.4 - 5 false 005:02.5 - 6 false 005:02.6 - 7 false 005:02.7 - 8 false 005:03.0 - 9 false 005:03.1 - 10 false 005:03.2 - 11 false 005:03.3 - 12 false 005:03.4 - 13 false 005:03.5 - 14 false 005:03.6 - 15 false 005:03.7 -

16. Install the Marvell drivers for the adapters detected in the VM. Use the latest drivers available from your vendor for your host OS (do not use inbox drivers). The same driver version must be installed on the host and the VM.

17. Power on the VM, and then issue the ifconfig -a command to verify that the added network interface is listed.

18. As needed, add more VFs in the VM.

235 AH0054602-00 M

13 NVMe-oF Configuration with RDMA

Non-Volatile Memory Express over Fabrics (NVMe-oF) enables the use of alternate transports to PCIe to extend the distance over which an NVMe host device and an NVMe storage drive or subsystem can connect. NVMe-oF defines a common architecture that supports a range of storage networking fabrics for the NVMe block storage protocol over a storage networking fabric. This architecture includes enabling a front-side interface into storage systems, scaling out to large quantities of NVMe devices, and extending the distance within a data center over which NVMe devices and NVMe subsystems can be accessed.

The NVMe-oF configuration procedures and options described in this chapter apply to Ethernet-based RDMA protocols, including RoCE and iWARP. The development of NVMe-oF with RDMA is defined by a technical sub-group of the NVMe organization.

This chapter demonstrates how to configure NVMe-oF for a simple network. The example network comprises the following:

Two servers: an initiator and a target. The target server is equipped with a PCIe SSD drive.

Operating system: RHEL 7.6 and later, , RHEL 8.x and later, SLES 15.x and later

Two adapters: One 41xxx Series Adapter installed in each server. Each port can be independently configured to use RoCE, RoCEv2, or iWARP as the RDMA protocol over which NVMe-oF runs.

For RoCE and RoCEv2, an optional switch configured for data center bridging (DCB), relevant quality of service (QoS) policy, and vLANs to carry the NVMe-oFs RoCE/RoCEv2 DCB traffic class priority. The switch is not needed when NVMe-oF is using iWARP.

13NVMe-oF Configuration with RDMA

236 AH0054602-00 M

Figure 13-1 illustrates an example network.

Figure 13-1. NVMe-oF Network

The NVMe-oF configuration process covers the following procedures:

Installing Device Drivers on Both Servers

Configuring the Target Server

Configuring the Initiator Server

Preconditioning the Target Server

Testing the NVMe-oF Devices

Optimizing Performance

41xxx Series Adapter41xxx Series Adapter

13NVMe-oF Configuration with RDMA Installing Device Drivers on Both Servers

237 AH0054602-00 M

Installing Device Drivers on Both Servers After installing your operating system (SLES 12 SP3), install device drivers on both servers. To upgrade the kernel to the latest Linux upstream kernel, go to:

https://www.kernel.org/pub/linux/kernel/v4.x/

1. Install and load the latest FastLinQ drivers (qed, qede, libqedr/qedr) following all installation instructions in the README.

2. (Optional) If you upgraded the OS kernel, you must reinstall and load the latest driver as follows:

a. Install the latest FastLinQ firmware following all installation instructions in the README.

b. Install the OS RDMA support applications and libraries by issuing the following commands: # yum groupinstall "Infiniband Support" # yum install tcl-devel libibverbs-devel libnl-devel glib2-devel libudev-devel lsscsi perftest # yum install gcc make git ctags ncurses ncurses-devel openssl* openssl-devel elfutils-libelf-devel*

c. To ensure that NVMe OFED support is in the selected OS kernel, issue the following command: make menuconfig

d. Under Device Drivers, ensure that the following are enabled (set to M): NVM Express block devices NVM Express over Fabrics RDMA host driver NVMe Target support NVMe over Fabrics RDMA target support

e. (Optional) If the Device Drivers options are not already present, rebuild the kernel by issuing the following commands: # make # make modules # make modules_install # make install

f. If changes were made to the kernel, reboot to that new OS kernel. For instructions on how to set the default boot kernel, go to:

https://wiki.centos.org/HowTos/Grub2

13NVMe-oF Configuration with RDMA Configuring the Target Server

238 AH0054602-00 M

3. Enable and start the RDMA service as follows: # systemctl enable rdma.service # systemctl start rdma.service Disregard the RDMA Service Failed error. All OFED modules required by qedr are already loaded.

Configuring the Target Server Configure the target server after the reboot process. After the server is operating, you cannot change the configuration without rebooting. If you are using a startup script to configure the target server, consider pausing the script (using the wait command or something similar) as needed to ensure that each command finishes before executing the next command.

To configure the target service: 1. Load target modules. Issue the following commands after each server

reboot: # modprobe qedr # modprobe nvmet; modprobe nvmet-rdma # lsmod | grep nvme (confirm that the modules are loaded)

2. Create the target subsystem NVMe Qualified Name (NQN) with the name indicated by . Use the NVMe-oF specifications; for example, nqn. - .org. .

# mkdir /sys/kernel/config/nvmet/subsystems/ # cd /sys/kernel/config/nvmet/subsystems/ 3. Create multiple unique NQNs for additional NVMe devices as needed.

4. Set the target parameters, as listed in Table 13-1.

Table 13-1. Target Parameters

Command Description

# echo 1 > attr_allow_any_host Allows any host to connect.

# mkdir namespaces/1 Creates a namespace.

13NVMe-oF Configuration with RDMA Configuring the Target Server

239 AH0054602-00 M

5. Create a symbolic link (symlink) to the newly created NQN subsystem:

# ln -s /sys/kernel/config/nvmet/subsystems/ nvme-subsystem-name subsystems/nvme-subsystem-name

6. Confirm that the NVMe target is listening on the port as follows: # dmesg | grep nvmet_rdma [ 8769.470043] nvmet_rdma: enabling port 1 (1.1.1.1:4420)

# echo -n /dev/nvme0n1 >namespaces/ 1/device_path

Sets the NVMe device path. The NVMe device path can differ between systems. Check the device path using the lsblk command. This system has two NVMe devices: nvme0n1 and nvme1n1.

# echo 1 > namespaces/1/enable Enables the namespace.

# mkdir /sys/kernel/config/nvmet/ ports/1 # cd /sys/kernel/config/nvmet/ports/1

Creates NVMe port 1.

# echo 1.1.1.1 > addr_traddr Sets the same IP address. For example, 1.1.1.1 is the IP address for the target port of the 41xxx Series Adapter.

# echo rdma > addr_trtype Sets the transport type RDMA.

# echo 4420 > addr_trsvcid Sets the RDMA port number. The socket port num- ber for NVMe-oF is typically 4420. However, any port number can be used if it is used consistently throughout the configuration.

# echo ipv4 > addr_adrfam Sets the IP address type.

Table 13-1. Target Parameters (Continued)

Command Description

13NVMe-oF Configuration with RDMA Configuring the Initiator Server

240 AH0054602-00 M

Configuring the Initiator Server You must configure the initiator server after the reboot process. After the server is operating, you cannot change the configuration without rebooting. If you are using a startup script to configure the initiator server, consider pausing the script (using the wait command or something similar) as needed to ensure that each command finishes before executing the next command.

To configure the initiator server: 1. Load the NVMe modules. Issue these commands after each server reboot:

# modprobe qedr # modprobe nvme-rdma

2. Download, compile and install the nvme-cli initiator utility. Issue these commands at the first configurationyou do not need to issue these commands after each reboot. # git clone https://github.com/linux-nvme/nvme-cli.git # cd nvme-cli # make && make install

3. Verify the installation version as follows: # nvme version

4. Discover the NVMe-oF target as follows: # nvme discover -t rdma -a 1.1.1.1 -s 1023 Make note of the subsystem NQN (subnqn) of the discovered target (Figure 13-2) for use in Step 5.

Figure 13-2. Subsystem NQN

13NVMe-oF Configuration with RDMA Preconditioning the Target Server

241 AH0054602-00 M

5. Connect to the discovered NVMe-oF target (nvme-qlogic-tgt1) using the NQN. Issue the following command after each server reboot. For example: # nvme connect -t rdma -n nvme-qlogic-tgt1 -a 1.1.1.1 -s 1023

6. Confirm the NVMe-oF target connection with the NVMe-oF device as follows: # dmesg | grep nvme # lsblk # list nvme Figure 13-3 shows an example.

Figure 13-3. Confirm NVMe-oF Connection

Preconditioning the Target Server NVMe target servers that are tested out-of-the-box show a higher-than-expected performance. Before running a benchmark, the target server needs to be prefilled or preconditioned.

To precondition the target server: 1. Secure-erase the target server with vendor-specific tools (similar to

formatting). This test example uses an Intel NVMe SSD device, which requires the Intel Data Center Tool that is available at the following link:

https://downloadcenter.intel.com/download/23931/Intel-Solid-State-Drive- Data-Center-Tool

2. Precondition the target server (nvme0n1) with data, which guarantees that all available memory is filled. This example uses the DD disk utility: # dd if=/dev/zero bs=1024k of=/dev/nvme0n1

13NVMe-oF Configuration with RDMA Testing the NVMe-oF Devices

242 AH0054602-00 M

Testing the NVMe-oF Devices Compare the latency of the local NVMe device on the target server with that of the NVMe-oF device on the initiator server to show the latency that NVMe adds to the system.

To test the NVMe-oF device: 1. Update the Repository (Repo) source and install the Flexible Input/Output

(FIO) benchmark utility on both the target and initiator servers by issuing the following commands: # yum install epel-release # yum install fio

Figure 13-4. FIO Utility Installation

2. Run the FIO utility to measure the latency of the initiator NVMe-oF device. Issue the following command: # fio --filename=/dev/nvme0n1 --direct=1 --time_based --rw=randread --refill_buffers --norandommap --randrepeat=0 --ioengine=libaio --bs=4k --iodepth=1 --numjobs=1 --runtime=60 --group_reporting --name=temp.out FIO reports two latency types: submission and completion. Submission latency (slat) measures application-to-kernel latency. Completion latency (clat), measures end-to-end kernel latency. The industry-accepted method is to read clat percentiles in the 99.00th range.

In this example, the initiator device NVMe-oF latency is 30sec.

3. Run FIO to measure the latency of the local NVMe device on the target server. Issue the following command: # fio --filename=/dev/nvme0n1 --direct=1 --time_based --rw=randread --refill_buffers --norandommap --randrepeat=0 --ioengine=libaio --bs=4k --iodepth=1 --numjobs=1 --runtime=60 --group_reporting --name=temp.out

13NVMe-oF Configuration with RDMA Optimizing Performance

243 AH0054602-00 M

In this example, the target NVMe device latency is 8sec. The total latency that results from the use of NVMe-oF is the difference between the initiator device NVMe-oF latency (30sec) and the target device NVMe-oF latency (8sec), or 22sec.

4. Run FIO to measure bandwidth of the local NVMe device on the target server. Issue the following command: fio --verify=crc32 --do_verify=1 --bs=8k --numjobs=1 --iodepth=32 --loops=1 --ioengine=libaio --direct=1 --invalidate=1 --fsync_on_close=1 --randrepeat=1 --norandommap --time_based --runtime=60 --filename=/dev/nvme0n1 --name=Write-BW-to-NVMe-Device --rw=randwrite Where --rw can be randread for reads only, randwrite for writes only, or randrw for reads and writes.

Optimizing Performance To optimize performance on both initiator and target servers: 1. Configure the following system BIOS settings:

Power Profiles = 'Max Performance' or equivalent ALL C-States = Disabled Hyperthreading = Disabled

2. Configure the Linux kernel parameters by editing the grub file (/etc/default/grub).

a. Add parameters to end of line GRUB_CMDLINE_LINUX: GRUB_CMDLINE_LINUX="nosoftlockup intel_idle.max_cstate=0 processor.max_cstate=1 mce=ignore_ce idle=poll"

b. Save the grub file.

c. Rebuild the grub file.

To rebuild the grub file for a legacy BIOS boot, issue the following command:

# grub2-mkconfig -o /boot/grub2/grub.cfg (Legacy BIOS boot)

To rebuild the grub file for an EFI boot, issue the following command:

# grub2-mkconfig -o /boot/efi/EFI/ /grub.cfg (EFI boot)

d. Reboot the server to implement the changes.

13NVMe-oF Configuration with RDMA Optimizing Performance

244 AH0054602-00 M

3. Set the IRQ affinity for all 41xxx Series Adapters. The multi_rss-affin.sh file is a script file that is listed in IRQ Affinity (multi_rss-affin.sh) on page 244. # systemctl stop irqbalance # ./multi_rss-affin.sh eth1

4. Set the CPU frequency. The cpufreq.sh file is a script that is listed in CPU Frequency (cpufreq.sh) on page 245. # ./cpufreq.sh

The following sections list the scripts that are used in Steps 3 and 4.

IRQ Affinity (multi_rss-affin.sh) The following script sets the IRQ affinity.

#!/bin/bash #RSS affinity setup script #input: the device name (ethX) #OFFSET=0 0/1 0/1/2 0/1/2/3 #FACTOR=1 2 3 4 OFFSET=0 FACTOR=1 LASTCPU='cat /proc/cpuinfo | grep processor | tail -n1 | cut -d":" -f2' MAXCPUID='echo 2 $LASTCPU ^ p | dc' OFFSET='echo 2 $OFFSET ^ p | dc' FACTOR='echo 2 $FACTOR ^ p | dc' CPUID=1

for eth in $*; do

NUM='grep $eth /proc/interrupts | wc -l' NUM_FP=$((${NUM}))

INT='grep -m 1 $eth /proc/interrupts | cut -d ":" -f 1'

echo "$eth: ${NUM} (${NUM_FP} fast path) starting irq ${INT}"

NOTE A different version of this script, qedr_affin.sh, is in the 41xxx Linux Source Code Package in the \add-ons\performance\roce directory. For an explanation of the IRQ affinity settings, refer to the multiple_irqs.txt file in that directory.

13NVMe-oF Configuration with RDMA Optimizing Performance

245 AH0054602-00 M

CPUID=$((CPUID*OFFSET)) for ((A=1; A<=${NUM_FP}; A=${A}+1)) ; do INT='grep -m $A $eth /proc/interrupts | tail -1 | cut -d ":" -f 1' SMP='echo $CPUID 16 o p | dc' echo ${INT} smp affinity set to ${SMP} echo $((${SMP})) > /proc/irq/$((${INT}))/smp_affinity CPUID=$((CPUID*FACTOR)) if [ ${CPUID} -gt ${MAXCPUID} ]; then CPUID=1 CPUID=$((CPUID*OFFSET)) fi done done

CPU Frequency (cpufreq.sh) The following script sets the CPU frequency.

#Usage "./nameofscript.sh" grep -E '^model name|^cpu MHz' /proc/cpuinfo cat /sys/devices/system/cpu/cpu0/cpufreq/scaling_governor for CPUFREQ in /sys/devices/system/cpu/cpu*/cpufreq/scaling_governor; do [ -f $CPUFREQ ] || continue; echo -n performance > $CPUFREQ; done cat /sys/devices/system/cpu/cpu0/cpufreq/scaling_governor

To configure the network or memory settings: sysctl -w net.ipv4.tcp_mem="16777216 16777216 16777216" sysctl -w net.ipv4.tcp_wmem="4096 65536 16777216" sysctl -w net.ipv4.tcp_rmem="4096 87380 16777216" sysctl -w net.core.wmem_max=16777216 sysctl -w net.core.rmem_max=16777216 sysctl -w net.core.wmem_default=16777216 sysctl -w net.core.rmem_default=16777216 sysctl -w net.core.optmem_max=16777216 sysctl -w net.ipv4.tcp_low_latency=1 sysctl -w net.ipv4.tcp_timestamps=0 sysctl -w net.ipv4.tcp_sack=1 sysctl -w net.ipv4.tcp_window_scaling=0 sysctl -w net.ipv4.tcp_adv_win_scale=1

13NVMe-oF Configuration with RDMA Optimizing Performance

246 AH0054602-00 M

# echo 0 > /sys/block/nvme0n1/queue/add_random # echo 2 > /sys/block/nvme0n1/queue/nomerges

NOTE The following commands apply only to the initiator server.

247 AH0054602-00 M

14 VXLAN Configuration

This chapter provides instructions for:

Configuring VXLAN in Linux

Configuring VXLAN in VMware on page 249

Configuring VXLAN in Windows Server 2016 on page 250

Configuring VXLAN in Linux To configure VXLAN in Linux: 1. Download, extract, and configure the openvswitch (OVS) tar ball.

a. Download the appropriate openvswitch release from the following location:

http://www.openvswitch.org/download/

b. Extract the tar ball by navigating to the directory where you downloaded the openvswitch release, and then issue the following command:

./configure;make;make install (compilation)

c. Configure openvswitch by issuing the following commands: modprobe -v openvswitch export PATH=$PATH:/usr/local/share/openvswitch/scripts ovs-ctl start ovs-ctl status When running ovs-ctl status, the ovsdb-server and ovs-vswitchd should be running with pid. For example: [root@localhost openvswitch-2.11.1]# ovs-ctl status ovsdb-server is running with pid 8479 ovs-vswitchd is running with pid 8496

14VXLAN Configuration Configuring VXLAN in Linux

248 AH0054602-00 M

2. Create the bridge.

a. To configure Host 1, issue the following commands: ovs-vsctl add-br br0 ovs-vsctl add-br br1 ovs-vsctl add-port br0 eth0 ifconfig eth0 0 && ifconfig br0 192.168.1.10 netmask 255.255.255.0 route add default gw 192.168.1.1 br0 ifconfig br1 10.1.2.10 netmask 255.255.255.0 ovs-vsctl add-port br1 vx1 -- set interface vx1 type=vxlan options:remote_ip=192.168.1.11 (peer IP address)

b. To configure Host 2, issue the following commands: ovs-vsctl add-br br0 ovs-vsctl add-br br1 ovs-vsctl add-port br0 eth0 ifconfig eth0 0 && ifconfig br0 192.168.1.11 netmask 255.255.255.0 route add default gw 192.168.1.1 br0 ifconfig br1 10.1.2.11 netmask 255.255.255.0 ovs-vsctl add-port br1 vx1 -- set interface vx1 type=vxlan options: remote_ip=192.168.1.10

3. Verify the configuration.

Run traffic between the host and peer using iperf. Ensure that the firewall and iptables stop and clean, respectively.

14VXLAN Configuration Configuring VXLAN in VMware

249 AH0054602-00 M

4. Configure the bridge as a passthrough to the VMs, and then check connectivity from the VM to the Peer.

a. Create a VM through virt-manager.

b. As there is no option to attach bridge br1 through virt-manager, change the xml file as follows

Issue the following command: command: virsh edit vm1 Add the following code:

c. Power up the VM and check br1 interfaces.

Ensure that br1 is in the OS. The br1 interface is named eth0, ens7; manually configure the static IP through th network device file and assign the same subnet IP to the peer (Host 2 VM).

Run traffic from the peer to the VM.

Configuring VXLAN in VMware To configure VXLAN in VMware, follow the instructions in the following locations:

https://docs.vmware.com/en/VMware-NSX-Data-Center-for-vSphere/6.3/com.vm ware.nsx.cross-vcenter-install.doc/GUID-49BAECC2-B800-4670-AD8C-A5292E D6BC19.html

https://www.vmware.com/content/dam/digitalmarketing/vmware/en/pdf/products/n sx/vmw-nsx-network-virtualization-design-guide.pdf

NOTE You can use this procedure to test other tunnels, such as Generic Network Virtualization Encapsulation (GENEVE) and generic routing encapsulation (GRE), with OVS. If you do not want to use OVS, you can continue with the legacy bridge option brctl.

14VXLAN Configuration Configuring VXLAN in Windows Server 2016

250 AH0054602-00 M

https://pubs.vmware.com/nsx-63/topic/com.vmware.nsx.troubleshooting.doc/GUI D-EA1DB524-DD2E-4157-956E-F36BDD20CDB2.html

https://communities.vmware.com/api/core/v3/attachments/124957/data

Configuring VXLAN in Windows Server 2016 VXLAN configuration in Windows Server 2016 includes:

Enabling VXLAN Offload on the Adapter

Deploying a Software Defined Network

Enabling VXLAN Offload on the Adapter To enable VXLAN offload on the adapter: 1. Open the miniport properties, and then click the Advanced tab.

2. On the adapter properties Advanced page (Figure 14-1) under Property, select VXLAN Encapsulated Task Offload.

Figure 14-1. Advanced Properties: Enabling VXLAN

3. Set the Value to Enabled.

4. Click OK.

14VXLAN Configuration Configuring VXLAN in Windows Server 2016

251 AH0054602-00 M

Deploying a Software Defined Network To take advantage of VXLAN encapsulation task offload on virtual machines, you must deploy a Software Defined Networking (SDN) stack that utilizes a Microsoft Network Controller.

For more details, refer to the following Microsoft TechNet link on Software Defined Networking:

https://technet.microsoft.com/en-us/windows-server-docs/networking/sdn/ software-defined-networking--sdn-

252 AH0054602-00 M

15 Windows Server 2016

This chapter provides the following information for Windows Server 2016:

Configuring RoCE Interfaces with Hyper-V

RoCE over Switch Embedded Teaming on page 258

Configuring QoS for RoCE on page 259

Configuring VMMQ on page 268

Configuring Storage Spaces Direct on page 272

Configuring RoCE Interfaces with Hyper-V In Windows Server 2016, Hyper-V with Network Direct Kernel Provider Interface (NDKPI) Mode-2, host virtual network adapters (host virtual NICs) support RDMA.

RoCE configuration procedures in this section include:

Creating a Hyper-V Virtual Switch with an RDMA NIC

Adding a vLAN ID to Host Virtual NIC

Verifying If RoCE is Enabled

Adding Host Virtual NICs (Virtual Ports)

Mapping the SMB Drive and Running RoCE Traffic

NOTE DCBX is required for RoCE over Hyper-V. To configure DCBX, either: Configure through the HII (see Preparing the Adapter on page 129). Configure using QoS (see Configuring QoS for RoCE on page 259).

15Windows Server 2016 Configuring RoCE Interfaces with Hyper-V

253 AH0054602-00 M

Creating a Hyper-V Virtual Switch with an RDMA NIC Follow the procedures in this section to create a Hyper-V virtual switch and then enable RDMA in the host VNIC.

To create a Hyper-V virtual switch with an RDMA virtual NIC: 1. On all physical interfaces, set the value of the NetworkDirect Functionality

parameter to Enabled.

2. Launch Hyper-V Manager.

3. Click Virtual Switch Manager (see Figure 15-1).

Figure 15-1. Enabling RDMA in Host Virtual NIC

4. Create a virtual switch.

5. Select the Allow management operating system to share this network adapter check box.

In Windows Server 2016, a new parameterNetwork Direct (RDMA)is added in the Host virtual NIC.

To enable RDMA in a host virtual NIC: 1. Open the Hyper-V Virtual Ethernet Adapter Properties window.

2. Click the Advanced tab.

15Windows Server 2016 Configuring RoCE Interfaces with Hyper-V

254 AH0054602-00 M

3. On the Advanced page (Figure 15-2):

a. Under Property, select Network Direct (RDMA). b. Under Value, select Enabled.

c. Click OK.

Figure 15-2. Hyper-V Virtual Ethernet Adapter Properties

4. To enable RDMA through PowerShell, issue the following Windows PowerShell command: PS C:\Users\Administrator> Enable-NetAdapterRdma "vEthernet (New Virtual Switch)" PS C:\Users\Administrator>

Adding a vLAN ID to Host Virtual NIC To add a vLAN ID to a host virtual NIC: 1. To find the host virtual NIC name, issue the following Windows PowerShell

command: PS C:\Users\Administrator> Get-VMNetworkAdapter -ManagementOS

15Windows Server 2016 Configuring RoCE Interfaces with Hyper-V

255 AH0054602-00 M

Figure 15-3 shows the command output.

Figure 15-3. Windows PowerShell Command: Get-VMNetworkAdapter

2. To set the vLAN ID to the host virtual NIC, issue the following Windows PowerShell command: PS C:\Users\Administrator> Set-VMNetworkAdaptervlan -VMNetworkAdapterName "New Virtual Switch" -VlanId 5 -Access -ManagementOS

Verifying If RoCE is Enabled To verify if the RoCE is enabled: Issue the following Windows PowerShell command:

Get-NetAdapterRdma Command output lists the RDMA supported adapters as shown in Figure 15-4.

Figure 15-4. Windows PowerShell Command: Get-NetAdapterRdma

NOTE Note the following about adding a vLAN ID to a host virtual NIC: A vLAN ID must be assigned to a host virtual NIC. The same vLAN

ID must be assigned to ports on the switch. Make sure that the vLAN ID is not assigned to the physical

interface when using a host virtual NIC for RoCE. If you are creating more than one host virtual NIC, you can assign

a different vLAN to each host virtual NIC.

15Windows Server 2016 Configuring RoCE Interfaces with Hyper-V

256 AH0054602-00 M

Adding Host Virtual NICs (Virtual Ports) To add host virtual NICs: 1. To add a host virtual NIC, issue the following command:

Add-VMNetworkAdapter -SwitchName "New Virtual Switch" -Name SMB - ManagementOS

2. Enable RDMA on host virtual NICs as shown in To enable RDMA in a host virtual NIC: on page 253.

3. To assign a vLAN ID to the virtual port, issue the following command: Set-VMNetworkAdapterVlan -VMNetworkAdapterName SMB -VlanId 5 -Access -ManagementOS

Mapping the SMB Drive and Running RoCE Traffic To map the SMB drive and run the RoCE traffic: 1. Launch the Performance Monitor (Perfmon).

2. Complete the Add Counters dialog box (Figure 15-5) as follows:

a. Under Available counters, select RDMA Activity. b. Under Instances of selected object, select the adapter.

c. Click Add.

15Windows Server 2016 Configuring RoCE Interfaces with Hyper-V

257 AH0054602-00 M

Figure 15-5. Add Counters Dialog Box

If the RoCE traffic is running, counters appear as shown in Figure 15-6.

Figure 15-6. Performance Monitor Shows RoCE Traffic

15Windows Server 2016 RoCE over Switch Embedded Teaming

258 AH0054602-00 M

RoCE over Switch Embedded Teaming Switch Embedded Teaming (SET) is Microsofts alternative NIC teaming solution available to use in environments that include Hyper-V and the Software Defined Networking (SDN) stack in Windows Server 2016 Technical Preview. SET integrates limited NIC Teaming functionality into the Hyper-V Virtual Switch.

Use SET to group between one and eight physical Ethernet network adapters into one or more software-based virtual network adapters. These adapters provide fast performance and fault tolerance if a network adapter failure occurs. To be placed on a team, SET member network adapters must all be installed in the same physical Hyper-V host.

RoCE over SET procedures included in this section:

Creating a Hyper-V Virtual Switch with SET and RDMA Virtual NICs

Enabling RDMA on SET

Assigning a vLAN ID on SET

Running RDMA Traffic on SET

Creating a Hyper-V Virtual Switch with SET and RDMA Virtual NICs

To create a Hyper-V virtual switch with SET and RDMA virtual NICs: To create SET, issue the following Windows PowerShell command:

PS C:\Users\Administrator> New-VMSwitch -Name SET -NetAdapterName "Ethernet 2","Ethernet 3" -EnableEmbeddedTeaming $true Figure 15-7 shows command output.

Figure 15-7. Windows PowerShell Command: New-VMSwitch

Enabling RDMA on SET To enable RDMA on SET: 1. To view SET on the adapter, issue the following Windows PowerShell

command: PS C:\Users\Administrator> Get-NetAdapter "vEthernet (SET)"

15Windows Server 2016 Configuring QoS for RoCE

259 AH0054602-00 M

Figure 15-8 shows command output.

Figure 15-8. Windows PowerShell Command: Get-NetAdapter

2. To enable RDMA on SET, issue the following Windows PowerShell command: PS C:\Users\Administrator> Enable-NetAdapterRdma "vEthernet (SET)"

Assigning a vLAN ID on SET To assign a vLAN ID on SET: To assign a vLAN ID on SET, issue the following Windows PowerShell

command: PS C:\Users\Administrator> Set-VMNetworkAdapterVlan -VMNetworkAdapterName "SET" -VlanId 5 -Access -ManagementOS

Running RDMA Traffic on SET For information about running RDMA traffic on SET, go to:

https://technet.microsoft.com/en-us/library/mt403349.aspx

Configuring QoS for RoCE The two methods of configuring quality of service (QoS) include:

Configuring QoS by Disabling DCBX on the Adapter

Configuring QoS by Enabling DCBX on the Adapter

NOTE Note the following when adding a vLAN ID to a host virtual NIC: Make sure that the vLAN ID is not assigned to the physical Interface

when using a host virtual NIC for RoCE. If you are creating more than one host virtual NIC, a different vLAN can

be assigned to each host virtual NIC.

15Windows Server 2016 Configuring QoS for RoCE

260 AH0054602-00 M

Configuring QoS by Disabling DCBX on the Adapter All configuration must be completed on all of the systems in use before configuring QoS by disabling DCBX on the adapter. The priority-based flow control (PFC), enhanced transition services (ETS), and traffic classes configuration must be the same on the switch and server.

To configure QoS by disabling DCBX: 1. Disable DCBX on the adapter.

2. Using HII, set the RoCE Priority to 0.

3. To install the DCB role in the host, issue the following Windows PowerShell command: PS C:\Users\Administrators> Install-WindowsFeature Data-Center-Bridging

4. To set the DCBX Willing mode to False, issue the following Windows PowerShell command: PS C:\Users\Administrators> set-NetQosDcbxSetting -Willing 0

5. Enable QoS in the miniport as follows:

a. Open the miniport Properties, and then click the Advanced tab.

b. On the adapter properties Advanced page (Figure 15-9) under Property, select Quality of Service, and then set the value to Enabled.

c. Click OK.

15Windows Server 2016 Configuring QoS for RoCE

261 AH0054602-00 M

Figure 15-9. Advanced Properties: Enable QoS

6. Assign the vLAN ID to the interface as follows:

a. Open the miniport properties, and then click the Advanced tab.

b. On the adapter properties Advanced page (Figure 15-10) under Property, select VLAN ID, and then set the value.

c. Click OK.

NOTE The preceding step is required for priority flow control (PFC).

15Windows Server 2016 Configuring QoS for RoCE

262 AH0054602-00 M

Figure 15-10. Advanced Properties: Setting VLAN ID

7. To enable PFC for RoCE on a specific priority, issue the following command: PS C:\Users\Administrators> Enable-NetQoSFlowControl -Priority 5

8. To disable priority flow control on any other priority, issue the following commands:

PS C:\Users\Administrator> Disable-NetQosFlowControl 0,1,2,3,4,6,7 PS C:\Users\Administrator> Get-NetQosFlowControl Priority Enabled PolicySet IfIndex IfAlias -------- ------- --------- ------- ------- 0 False Global 1 False Global 2 False Global 3 False Global 4 False Global

NOTE If configuring RoCE over Hyper-V, do not assign a vLAN ID to the physical interface.

15Windows Server 2016 Configuring QoS for RoCE

263 AH0054602-00 M

5 True Global 6 False Global 7 False Global

9. To configure QoS and assign relevant priority to each type of traffic, issue the following commands (where Priority 5 is tagged for RoCE and Priority 0 is tagged for TCP):

PS C:\Users\Administrators> New-NetQosPolicy "SMB" -NetDirectPortMatchCondition 445 -PriorityValue8021Action 5 -PolicyStore ActiveStore PS C:\Users\Administrators> New-NetQosPolicy "TCP" -IPProtocolMatchCondition TCP -PriorityValue8021Action 0 -Policystore ActiveStore PS C:\Users\Administrator> Get-NetQosPolicy -PolicyStore activestore Name : tcp Owner : PowerShell / WMI NetworkProfile : All Precedence : 127 JobObject : IPProtocol : TCP PriorityValue : 0

Name : smb Owner : PowerShell / WMI NetworkProfile : All Precedence : 127 JobObject : NetDirectPort : 445 PriorityValue : 5

10. To configure ETS for all traffic classes defined in the previous step, issue the following commands:

PS C:\Users\Administrators> New-NetQosTrafficClass -name "RDMA class" -priority 5 -bandwidthPercentage 50 -Algorithm ETS PS C:\Users\Administrators> New-NetQosTrafficClass -name "TCP class" -priority 0 -bandwidthPercentage 30 -Algorithm ETS PS C:\Users\Administrator> Get-NetQosTrafficClass

15Windows Server 2016 Configuring QoS for RoCE

264 AH0054602-00 M

Name Algorithm Bandwidth(%) Priority PolicySet IfIndex IfAlias ---- --------- ------------ -------- --------- ------- ------- [Default] ETS 20 1-4,6-7 Global RDMA class ETS 50 5 Global TCP class ETS 30 0 Global

11. To see the network adapter QoS from the preceding configuration, issue the following Windows PowerShell command:

PS C:\Users\Administrator> Get-NetAdapterQos Name : SLOT 4 Port 1 Enabled : True Capabilities : Hardware Current -------- ------- MacSecBypass : NotSupported NotSupported DcbxSupport : None None NumTCs(Max/ETS/PFC) : 4/4/4 4/4/4

OperationalTrafficClasses : TC TSA Bandwidth Priorities -- --- --------- ---------- 0 ETS 20% 1-4,6-7 1 ETS 50% 5 2 ETS 30% 0

OperationalFlowControl : Priority 5 Enabled OperationalClassifications : Protocol Port/Type Priority -------- --------- -------- Default 0 NetDirect 445 5

12. Create a startup script to make the settings persistent across the system reboots.

13. Run RDMA traffic and verify as described in RoCE Configuration on page 127.

Configuring QoS by Enabling DCBX on the Adapter All configuration must be completed on all of the systems in use. The PFC, ETS, and traffic classes configuration must be the same on the switch and server.

To configure QoS by enabling DCBX: 1. Enable DCBX (IEEE, CEE, or Dynamic).

2. Using HII, set the RoCE Priority to 0.

15Windows Server 2016 Configuring QoS for RoCE

265 AH0054602-00 M

3. To install the DCB role in the host, issue the following Windows PowerShell command: PS C:\Users\Administrators> Install-WindowsFeature Data-Center-Bridging

4. To set the DCBX Willing mode to True, issue the following command: PS C:\Users\Administrators> set-NetQosDcbxSetting -Willing 1

5. Enable QoS in the miniport properties as follows:

a. On the adapter properties Advanced page (Figure 15-11) under Property, select Quality of Service, and then set the value to Enabled.

b. Click OK.

NOTE If the switch does not have a way of designating the RoCE traffic, you may need to set the RoCE Priority to the number used by the switch. Arista switches can do so, but some other switches cannot.

NOTE For this configuration, set the DCBX Protocol to CEE.

15Windows Server 2016 Configuring QoS for RoCE

266 AH0054602-00 M

Figure 15-11. Advanced Properties: Enabling QoS

6. Assign the vLAN ID to the interface (required for PFC) as follows:

a. Open the miniport properties, and then click the Advanced tab.

b. On the adapter properties Advanced page (Figure 15-12) under Property, select VLAN ID, and then set the value.

c. Click OK.

15Windows Server 2016 Configuring QoS for RoCE

267 AH0054602-00 M

Figure 15-12. Advanced Properties: Setting VLAN ID

7. To configure the switch, issue the following Windows PowerShell command: PS C:\Users\Administrators> Get-NetAdapterQoS Name : Ethernet 5 Enabled : True Capabilities : Hardware Current -------- ------- MacSecBypass : NotSupported NotSupported DcbxSupport : CEE CEE NumTCs(Max/ETS/PFC) : 4/4/4 4/4/4

OperationalTrafficClasses : TC TSA Bandwidth Priorities -- --- --------- ---------- 0 ETS 5% 0-4,6-7 1 ETS 95% 5

OperationalFlowControl : Priority 5 Enabled

15Windows Server 2016 Configuring VMMQ

268 AH0054602-00 M

OperationalClassifications : Protocol Port/Type Priority -------- --------- -------- NetDirect 445 5

RemoteTrafficClasses : TC TSA Bandwidth Priorities -- --- --------- ---------- 0 ETS 5% 0-4,6-7 1 ETS 95% 5

RemoteFlowControl : Priority 5 Enabled RemoteClassifications : Protocol Port/Type Priority -------- --------- -------- NetDirect 445 5

Configuring VMMQ Virtual machine multiqueue (VMMQ) configuration information includes:

Enabling VMMQ on the Adapter

Creating a Virtual Machine Switch with or Without SR-IOV

Enabling VMMQ on the Virtual Machine Switch

Getting the Virtual Machine Switch Capability

Creating a VM and Enabling VMMQ on VMNetworkAdapters in the VM

Enabling and Disabling VMMQ on a Management NIC

Monitoring Traffic Statistics

NOTE The preceding example is taken when the adapter port is connected to an Arista 7060X switch. In this example, the switch PFC is enabled on Priority 5. RoCE App TLVs are defined. The two traffic classes are defined as TC0 and TC1, where TC1 is defined for RoCE. DCBX Protocol mode is set to CEE. For Arista switch configuration, refer to Preparing the Ethernet Switch on page 129. When the adapter is in Willing mode, it accepts Remote Configuration and shows it as Operational Parameters.

15Windows Server 2016 Configuring VMMQ

269 AH0054602-00 M

Enabling VMMQ on the Adapter To enable VMMQ on the adapter: 1. Open the miniport properties, and then click the Advanced tab.

2. On the adapter properties Advanced page (Figure 15-13) under Property, select Virtual Switch RSS, and then set the value to Enabled.

3. Click OK.

Figure 15-13. Advanced Properties: Enabling Virtual Switch RSS

Creating a Virtual Machine Switch with or Without SR-IOV To create a virtual machine switch with or without SR-IOV: 1. Launch the Hyper-V Manager.

2. Select Virtual Switch Manager (see Figure 15-14).

3. In the Name box, type a name for the virtual switch.

4. Under Connection type:

a. Click External network.

b. Select the Allow management operating system to share this network adapter check box.

15Windows Server 2016 Configuring VMMQ

270 AH0054602-00 M

Figure 15-14. Virtual Switch Manager

5. Click OK.

Enabling VMMQ on the Virtual Machine Switch To enable VMMQ on the virtual machine switch: Issue the following Windows PowerShell command:

PS C:\Users\Administrators> Set-VMSwitch -name q1 -defaultqueuevmmqenabled $true -defaultqueuevmmqqueuepairs 4

15Windows Server 2016 Configuring VMMQ

271 AH0054602-00 M

Getting the Virtual Machine Switch Capability To get the virtual machine switch capability: Issue the following Windows PowerShell command:

PS C:\Users\Administrator> Get-VMSwitch -Name ql | fl Figure 15-15 shows example output.

Figure 15-15. Windows PowerShell Command: Get-VMSwitch

Creating a VM and Enabling VMMQ on VMNetworkAdapters in the VM

To create a virtual machine (VM) and enable VMMQ on VMNetworksadapters in the VM: 1. Create a VM.

2. Add the VMNetworkadapter to the VM.

3. Assign a virtual switch to the VMNetworkadapter.

15Windows Server 2016 Configuring Storage Spaces Direct

272 AH0054602-00 M

4. To enable VMMQ on the VM, issue the following Windows PowerShell command: PS C:\Users\Administrators> set-vmnetworkadapter -vmname vm1 -VMNetworkAdapterName "network adapter" -vmmqenabled $true -vmmqqueuepairs 4

Enabling and Disabling VMMQ on a Management NIC To enable or disable VMMQ on a management NIC: To enable VMMQ on a management NIC, issue the following command:

PS C:\Users\Administrator> Set-VMNetworkAdapter ManagementOS vmmqEnabled $true

To disable VMMQ on a management NIC, issue the following command: PS C:\Users\Administrator> Set-VMNetworkAdapter ManagementOS vmmqEnabled $false A VMMQ will also be available for the multicast open shortest path first (MOSPF).

Monitoring Traffic Statistics To monitor virtual function traffic in a virtual machine, issue the following Windows PowerShell command: PS C:\Users\Administrator> Get-NetAdapterStatistics | fl

Configuring Storage Spaces Direct Windows Server 2016 introduces Storage Spaces Direct, which allows you to build highly available and scalable storage systems with local storage. For more information, refer to the following Microsoft TechNet link:

https://technet.microsoft.com/en-us/windows-server-docs/storage/storage-spaces /storage-spaces-direct-windows-server-2016

NOTE Marvell supports the new parameter added for Windows Server 2016 and Windows Server 2019 to configure the maximum quantity of queue pairs on a virtual port. For details, see Max Queue Pairs (L2) Per VPort on page 282.

15Windows Server 2016 Configuring Storage Spaces Direct

273 AH0054602-00 M

Configuring the Hardware Figure 15-16 shows an example of hardware configuration.

Figure 15-16. Example Hardware Configuration

Deploying a Hyper-Converged System This section includes instructions to install and configure the components of a Hyper-Converged system using the Windows Server 2016. The act of deploying a Hyper-Converged system can be divided into the following three high-level phases:

Deploying the Operating System

Configuring the Network

Configuring Storage Spaces Direct

NOTE The disks used in this example are 4 400G NVMe, and 12 200G SSD disks.

15Windows Server 2016 Configuring Storage Spaces Direct

274 AH0054602-00 M

Deploying the Operating System To deploy the operating systems: 1. Install the operating system.

2. Install the Windows Server roles (Hyper-V).

3. Install the following features:

Failover Cluster Data center bridging (DCB)

4. Connect the nodes to a domain and add domain accounts.

Configuring the Network To deploy Storage Spaces Direct, the Hyper-V switch must be deployed with RDMA-enabled host virtual NICs.

To configure the network on each server: 1. Configure the physical network switch as follows:

a. Connect all adapter NICs to the switch port.

b. Enable the switch port and make sure that:

The switch port supports switch-independent teaming mode. The switch port is part of multiple vLAN networks.

Example Dell switch configuration: no ip address mtu 9416 portmode hybrid switchport dcb-map roce_S2D protocol lldp

NOTE The following procedure assumes that there are four RDMA NIC ports.

NOTE If your test adapter has more than one NIC port, you must connect both ports to the same switch.

15Windows Server 2016 Configuring Storage Spaces Direct

275 AH0054602-00 M

dcbx version cee no shutdown

2. Enable Network Quality of Service.

3. Create a Hyper-V virtual switch with Switch Embedded Teaming (SET) and RDMA virtual NIC as follows:

a. To identify the network adapters, issue the following command: Get-NetAdapter | FT Name,InterfaceDescription,Status,LinkSpeed

b. To create a virtual switch connected to all of the physical network adapters, and to then enable SET, issue the following command: New-VMSwitch -Name SETswitch -NetAdapterName " "," "," "," " EnableEmbeddedTeaming $true

c. To add host virtual NICs to the virtual switch, issue the following commands: Add-VMNetworkAdapter SwitchName SETswitch Name SMB_1 managementOS Add-VMNetworkAdapter SwitchName SETswitch Name SMB_2 managementOS

d. To configure the host virtual NIC to use a vLAN, issue the following commands: Set-VMNetworkAdapterVlan -VMNetworkAdapterName "SMB_1" -VlanId 5 -Access -ManagementOS Set-VMNetworkAdapterVlan -VMNetworkAdapterName "SMB_2" -VlanId 5 -Access -ManagementOS

NOTE Network Quality of Service is used to ensure that the Software Defined Storage system has enough bandwidth to communicate between the nodes to ensure resiliency and performance. To configure QoS on the adapter, see Configuring QoS for RoCE on page 259.

NOTE The preceding commands configure the virtual NIC from the virtual switch that you just configured for the management operating system to use.

15Windows Server 2016 Configuring Storage Spaces Direct

276 AH0054602-00 M

e. To verify that the vLAN ID is set, issue the following command: Get-VMNetworkAdapterVlan -ManagementOS

f. To disable and enable each host virtual NIC adapter so that the vLAN is active, issue the following commands: Disable-NetAdapter "vEthernet (SMB_1)" Enable-NetAdapter "vEthernet (SMB_1)" Disable-NetAdapter "vEthernet (SMB_2)" Enable-NetAdapter "vEthernet (SMB_2)"

g. To enable RDMA on the host virtual NIC adapters, issue the following command: Enable-NetAdapterRdma "SMB1","SMB2"

h. To verify RDMA capabilities, issue the following command: Get-SmbClientNetworkInterface | where RdmaCapable -EQ $true

Configuring Storage Spaces Direct Configuring Storage Spaces Direct in Windows Server 2016 includes the following steps:

Step 1. Running a Cluster Validation Tool

Step 2. Creating a Cluster

Step 3. Configuring a Cluster Witness

Step 4. Cleaning Disks Used for Storage Spaces Direct

Step 5. Enabling Storage Spaces Direct

Step 6. Creating Virtual Disks

Step 7. Creating or Deploying Virtual Machines

Step 1. Running a Cluster Validation Tool Run the cluster validation tool to make sure server nodes are configured correctly to create a cluster using Storage Spaces Direct.

NOTE These commands can be on the same or different vLANs.

15Windows Server 2016 Configuring Storage Spaces Direct

277 AH0054602-00 M

To validate a set of servers for use as a Storage Spaces Direct cluster, issue the following Windows PowerShell command: Test-Cluster -Node MachineName4> -Include "Storage Spaces Direct", Inventory, Network, "System Configuration" Step 2. Creating a Cluster Create a cluster with the four nodes (which was validated for cluster creation) in Step 1. Running a Cluster Validation Tool.

To create a cluster, issue the following Windows PowerShell command: New-Cluster -Name -Node MachineName3, MachineName4> -NoStorage The NoStorage parameter is required. If it is not included, the disks are automatically added to the cluster, and you must remove them before enabling Storage Spaces Direct. Otherwise, they will not be included in the Storage Spaces Direct storage pool.

Step 3. Configuring a Cluster Witness You should configure a witness for the cluster, so that this four-node system can withstand two nodes failing or being offline. With these systems, you can configure file share witness or cloud witness.

For more information, go to:

https://docs.microsoft.com/en-us/windows-server/failover-clustering/manage-clust er-quorum

Step 4. Cleaning Disks Used for Storage Spaces Direct The disks intended to be used for Storage Spaces Direct must be empty and without partitions or other data. If a disk has partitions or other data, it will not be included in the Storage Spaces Direct system.

The following Windows PowerShell command can be placed in a Windows PowerShell script (.PS1) file and executed from the management system in an open Windows PowerShell (or Windows PowerShell ISE) console with Administrator privileges.

icm (Get-Cluster -Name HCNanoUSClu3 | Get-ClusterNode) { Update-StorageProviderCache

NOTE Running this script helps identify the disks on each node that can be used for Storage Spaces Direct. It also removes all data and partitions from those disks.

15Windows Server 2016 Configuring Storage Spaces Direct

278 AH0054602-00 M

Get-StoragePool |? IsPrimordial -eq $false | Set-StoragePool -IsReadOnly:$false -ErrorAction SilentlyContinue

Get-StoragePool |? IsPrimordial -eq $false | Get-VirtualDisk | Remove-VirtualDisk -Confirm:$false -ErrorAction SilentlyContinue

Get-StoragePool |? IsPrimordial -eq $false | Remove-StoragePool -Confirm:$false -ErrorAction SilentlyContinue

Get-PhysicalDisk | Reset-PhysicalDisk -ErrorAction SilentlyContinue

Get-Disk |? Number -ne $null |? IsBoot -ne $true |? IsSystem -ne $true |? PartitionStyle -ne RAW |% { $_ | Set-Disk -isoffline:$false $_ | Set-Disk -isreadonly:$false $_ | Clear-Disk -RemoveData -RemoveOEM -Confirm:$false $_ | Set-Disk -isreadonly:$true $_ | Set-Disk -isoffline:$true } Get-Disk |? Number -ne $null |? IsBoot -ne $true |? IsSystem -ne $true |? PartitionStyle -eq RAW | Group -NoElement -Property FriendlyName

} | Sort -Property PsComputerName,Count

Step 5. Enabling Storage Spaces Direct After creating the cluster, issue the Enable-ClusterS2D Windows PowerShell cmdlet. The cmdlet places the storage system into the Storage Spaces Direct mode and automatically does the following:

Creates a single, large pool that has a name such as S2D on Cluster1.

Configures a Storage Spaces Direct cache. If there is more than one media type available for Storage Spaces Direct use, it configures the most efficient type as cache devices (in most cases, read and write).

Creates two tiersCapacity and Performanceas default tiers. The cmdlet analyzes the devices and configures each tier with the mix of device types and resiliency.

Step 6. Creating Virtual Disks If the Storage Spaces Direct was enabled, it creates a single pool using all of the disks. It also names the pool (for example S2D on Cluster1), with the name of the cluster that is specified in the name.

15Windows Server 2016 Configuring Storage Spaces Direct

279 AH0054602-00 M

The following Windows PowerShell command creates a virtual disk with both mirror and parity resiliency on the storage pool: New-Volume -StoragePoolFriendlyName "S2D*" -FriendlyName -FileSystem CSVFS_ReFS -StorageTierfriendlyNames Capacity,Performance -StorageTierSizes , -CimSession

Step 7. Creating or Deploying Virtual Machines You can provision the virtual machines onto the nodes of the hyper-converged S2D cluster. Store the virtual machines files on the systems Cluster Shared Volume (CSV) namespace (for example, c:\ClusterStorage\Volume1), similar to clustered virtual machines on failover clusters.

280 AH0054602-00 M

16 Windows Server 2019

This chapter provides the following information for Windows Server 2019:

RSSv2 for Hyper-V

Windows Server 2019 Behaviors on page 281

New Adapter Properties on page 282

RSSv2 for Hyper-V In Windows Server 2019, Microsoft added support for Receive Side Scaling version 2 (RSSv2) with Hyper-V (RSSv2 per vPort).

RSSv2 Description Compared to RSSv1, RSSv2 decreases the time between the CPU load measurement and the indirection table update. This feature prevents slowdown during high-traffic situations. RSSv2 can dynamically spread receive queues over multiple processors much more responsively than RSSv1. For more information, visit the following Web page:

https://docs.microsoft.com/en-us/windows-hardware/drivers/network/receive-side- scaling-version-2-rssv2-

RSSv2 is supported by default in the Windows Server 2019 driver when the Virtual Switch RSS option is also enabled. This option is enabled (the default), and the NIC is bound to the Hyper-V or vSwitch.

16Windows Server 2019 Windows Server 2019 Behaviors

281 AH0054602-00 M

Known Event Log Errors Under typical operation, the dynamic algorithm of RSSv2 may initiate an indirection table update that is incompatible with the driver and return an appropriate status code. In such cases, an event log error occurs, even though no functional operation issue exists. Figure 16-1 shows an example.

Figure 16-1. RSSv2 Event Log Error

Windows Server 2019 Behaviors Windows Server 2019 introduced the following new behaviors affecting adapter configuration.

VMMQ Is Enabled by Default In the inbox driver of Windows Server 2019, the Virtual Switch RSS (VMMQ) option is enabled by default in the NIC properties. In addition, Microsoft changed the default behavior of the Virtual NICs option to have VMMQ enabled with the 16 queue pairs. This behavior change impacts the quantity of available resources.

For example, suppose the NIC supports 32 VMQs and 64 queue pairs. In Windows Server 2016, when you add 32 virtual NICs (VNICs), they will have VMQ acceleration. However in Windows Server 2019, you will get 4 VNICs with VMMQ acceleration, each with 16 queue pairs and 30 VNICs with no acceleration.

Because of this functionality, Marvell introduced a new user property, Max Queue Pairs (L2) Per VPort. For more details, see New Adapter Properties.

Inbox Driver Network Direct (RDMA) Is Disabled by Default In the inbox driver of Windows Server 2019, the Network Direct (RDMA) option is disabled by default in the NIC properties. However, when upgrading the driver to an out-of-box driver, Network Direct is enabled by default.

16Windows Server 2019 New Adapter Properties

282 AH0054602-00 M

New Adapter Properties New user-configurable properties available in Windows Server 2019 are described in the following sections:

Max Queue Pairs (L2) Per VPort

Network Direct Technology

Virtualization Resources

VMQ and VMMQ Default Accelerations

Single VPort Pool

Max Queue Pairs (L2) Per VPort As explained in VMMQ Is Enabled by Default, Windows 2019 (and Windows 2016) introduced a new user-configurable parameter, Max Queue Pairs (L2) per VPort. This parameter permits greater control of resource distribution by defining the maximum quantity of queue pairs that can be assigned to the following:

VPort-Default VPort PF Non-Default VPort (VMQ/VMMQ) SR-IOV Non-Default VPort (VF)1

The default value of the Max Queue Pairs (L2) per VPort parameter is set to Auto, which is one of the following:

Max Queue Pairs for Default vPort = 8 Max Queue Pairs for Non-Default vPort = 4

If you select a value less than 8, then:

Max Queue Pairs for Default vPort = 8 Max Queue Pairs for Non-Default vPort = value

If you select a value greater than 8, then:

Max Queue Pairs for Default vPort = value Max Queue Pairs for Non-Default vPort = value

Network Direct Technology Marvell supports the new Network Direct Technology parameter that allows you to select the underlying RDMA technology that adheres to the following Microsoft specification:

https://docs.microsoft.com/en-us/windows-hardware/drivers/network/inf-requirem ents-for-ndkpi

This option replaces the RDMA Mode parameter.

1 This parameter also applies to Windows Server 2016.

16Windows Server 2019 New Adapter Properties

283 AH0054602-00 M

Virtualization Resources Table 16-1 lists the maximum quantities of virtualization resources in Windows 2019 for Dell 41xxx Series Adapters.

Table 16-1. Windows 2019 Virtualization Resources for Dell 41xxx Series Adapters

Two-port NIC-only Single Function Non-CNA Quantity

Maximum VMQs 102

Maximum VFs 80

Maximum QPs 112

Four-port NIC-only Single Function Non-CNA Quantity

Maximum VMQs 47

Maximum VFs 32

Maximum QPs 48

16Windows Server 2019 New Adapter Properties

284 AH0054602-00 M

VMQ and VMMQ Default Accelerations Table 16-2 lists the VMQ and VMMQ default and other values for accelerations in Windows Server 2019 for Dell 41xxx Series Adapters.

Single VPort Pool The 41xxx Series Adapter supports the Single VPort Pool parameter, which allows the system administrator to assign any available IOVQueuePair to either Default-VPort, PF Non-Default VPort, or VF Non-Default VPort. To assign the value, issue the following Windows PowerShell commands:

Default-VPort: Set-VMSwitch -Name -DefaultQueueVmmqEnabled:1 -DefaultQueueVmmqQueuePairs:

Table 16-2. Windows 2019 VMQ and VMMQ Accelerations

Two-port NIC-only Single Function Non-CNA

Default Value Other Possible Values

Maximum Queue Pairs (L2) per VPort a

a Max Queue Pairs (L2) VPort is configurable parameter of NIC advanced properties.

Auto 1 2 4 8 16

Maximum VMQs 26 103 52 26 13 6

Default VPort Queue Pairs 8 8 8 8 8 16

PF Non-default VPort Queue Pairs 4 1 2 4 8 16

Four-port NIC-only Single Function Non-CNA

Default Value Other Possible Values

Maximum Queue Pairs (L2) per VPort a Auto 1 2 4 8 16

Maximum VMQs 10 40 20 10 5 2

Default VPort Queue Pairs 8 8 8 8 8 16

PF Non-default VPort Queue Pairs 4 1 2 4 8 16

NOTE Marvell does not recommend that you disable VMMQ or decrease the quantity of queue pairs for the Default-VPort, because it may impact system performance.

16Windows Server 2019 New Adapter Properties

285 AH0054602-00 M

PF Non-Default VPort:

For the host: Set-VMNetworkAdapter -ManagementOS -VmmqEnabled:1 -VmmqQueuePairs:

For the VM: Set-VMNetworkAdapter -VMName -VmmqEnabled:1 -VmmqQueuePairs:

VF Non-Default VPort: Set-VMNetworkAdapter -VMName -IovWeight:100 -IovQueuePairsRequested:

To apply multiple quantities of queue pairs to any vPort: The quantity of queue pairs must be less than or equal to the total number of

CPU cores on the system.

The quantity of queue pairs must be less than or equal to the value of Max Queue Pairs (L2) Per VPort. For more information, see Max Queue Pairs (L2) Per VPort.

NOTE The default quantity of QPs assigned for a VF (IovQueuePairsRequested) is still 1.

286 AH0054602-00 M

17 Troubleshooting

This chapter provides the following troubleshooting information:

Troubleshooting Checklist

Verifying that Current Drivers Are Loaded on page 287

Testing Network Connectivity on page 288

Microsoft Virtualization with Hyper-V on page 289

Linux-specific Issues on page 289

Miscellaneous Issues on page 289

Collecting Debug Data on page 290

Troubleshooting Checklist

The following checklist provides recommended actions to resolve problems that may arise while installing the 41xxx Series Adapter or running it in your system.

Inspect all cables and connections. Verify that the cable connections at the network adapter and the switch are attached properly.

Verify the adapter installation by reviewing Installing the Adapter on page 6. Ensure that the adapter is properly seated in the slot. Check for specific hardware problems, such as obvious damage to board components or the PCI edge connector.

Verify the configuration settings and change them if they are in conflict with another device.

Verify that your server is using the latest BIOS.

Try inserting the adapter in another slot. If the new position works, the original slot in your system may be defective.

CAUTION Before you open the server cabinet to add or remove the adapter, review the Safety Precautions on page 5.

17Troubleshooting Verifying that Current Drivers Are Loaded

287 AH0054602-00 M

Replace the failed adapter with one that is known to work properly. If the second adapter works in the slot where the first one failed, the original adapter is probably defective.

Install the adapter in another functioning system, and then run the tests again. If the adapter passes the tests in the new system, the original system may be defective.

Remove all other adapters from the system, and then run the tests again. If the adapter passes the tests, the other adapters may be causing contention.

Verifying that Current Drivers Are Loaded Ensure that the current drivers are loaded for your Windows, Linux, or VMware system.

Verifying Drivers in Windows See the Device Manager to view vital information about the adapter, link status, and network connectivity.

Verifying Drivers in Linux To verify that the qed.ko driver is loaded properly, issue the following command: # lsmod | grep -i If the driver is loaded, the output of this command shows the size of the driver in bytes. The following example shows the drivers loaded for the qed module: # lsmod | grep -i qed qed 199238 1 qede 1417947 0 If you reboot after loading a new driver, you can issue the following command to verify that the currently loaded driver is the correct version: modinfo qede Or, you can issue the following command: [root@test1]# ethtool -i eth2 driver: qede version: 8.4.7.0 firmware-version: mfw 8.4.7.0 storm 8.4.7.0 bus-info: 0000:04:00.2

17Troubleshooting Testing Network Connectivity

288 AH0054602-00 M

If you loaded a new driver, but have not yet rebooted, the modinfo command will not show the updated driver information. Instead, issue the following dmesg command to view the logs. In this example, the last entry identifies the driver that will be active upon reboot. # dmesg | grep -i "Cavium" | grep -i "qede" [ 10.097526] QLogic FastLinQ 4xxxx Ethernet Driver qede x.x.x.x [ 23.093526] QLogic FastLinQ 4xxxx Ethernet Driver qede x.x.x.x [ 34.975396] QLogic FastLinQ 4xxxx Ethernet Driver qede x.x.x.x [ 34.975896] QLogic FastLinQ 4xxxx Ethernet Driver qede x.x.x.x [ 3334.975896] QLogic FastLinQ 4xxxx Ethernet Driver qede x.x.x.x

Verifying Drivers in VMware To verify that the VMware ESXi drivers are loaded, issue the following command: # esxcli software vib list

Testing Network Connectivity This section provides procedures for testing network connectivity in Windows and Linux environments.

Testing Network Connectivity for Windows Test network connectivity using the ping command.

To determine if the network connection is working: 1. Click Start, and then click Run.

2. In the Open box, type cmd, and then click OK.

3. To view the network connection to be tested, issue the following command: ipconfig /all

4. Issue the following command, and then press ENTER. ping

The displayed ping statistics indicate whether or not the network connection is working.

NOTE When using forced link speeds, verify that both the adapter and the switch are forced to the same speed.

17Troubleshooting Microsoft Virtualization with Hyper-V

289 AH0054602-00 M

Testing Network Connectivity for Linux To verify that the Ethernet interface is up and running: 1. To check the status of the Ethernet interface, issue the ifconfig

command.

2. To check the statistics on the Ethernet interface, issue the netstat -i command.

To verify that the connection has been established: 1. Ping an IP host on the network. From the command line, issue the following

command: ping

2. Press ENTER.

The displayed ping statistics indicate whether or not the network connection is working.

The adapter link speed can be forced to 10Gbps or 25Gbps using either the operating system GUI tool or the ethtool command, ethtool s ethX speed SSSS.

Microsoft Virtualization with Hyper-V Microsoft Virtualization is a hypervisor virtualization system for Windows Server 2012 R2. For more information on Hyper-V, go to:

https://technet.microsoft.com/en-us/library/Dn282278.aspx

Linux-specific Issues Problem: Errors appear when compiling driver source code. Solution: Some installations of Linux distributions do not install the

development tools and kernel sources by default. Before compiling driver source code, ensure that the development tools for the Linux distribution that you are using are installed.

Miscellaneous Issues Problem: The 41xxx Series Adapter has shut down, and an error message

appears indicating that the fan on the adapter has failed. Solution: The 41xxx Series Adapter may intentionally shut down to prevent

permanent damage. Contact Marvell Technical Support for assistance.

17Troubleshooting Collecting Debug Data

290 AH0054602-00 M

Problem: In an ESXi environment, with the iSCSI driver (qedil) installed, sometimes, the VI-client cannot access the host. This is due to the termination of the hostd daemon, which affects connectivity with the VI-client.

Solution: Contact VMware technical support.

Collecting Debug Data Use the commands in Table 17-1 to collect debug data.

Table 17-1. Collecting Debug Data Commands

Debug Data Description

demesg -T Kernel logs

ethtool -d Register dump

sys_info.sh System information; available in the driver bundle

291 AH0054602-00 M

A Adapter LEDS

Table A-1 lists the LED indicators for the state of the adapter port link and activity.

Table A-1. Adapter Port Link and Activity LEDs

Port LED LED Appearance Network State

Link LED

Off No link (cable disconnected or port down)

Continuously illuminated GREEN Link at highest supported link speed

Continuously illuminated AMBER Link at lower supported link speed

Activity LED

Off No port activity

Blinking Port activity

292 AH0054602-00 M

B Cables and Optical Modules

This appendix provides the following information for the supported cables and optical modules:

Supported Specifications

Tested Cables and Optical Modules on page 293

Tested Switches on page 297

Supported Specifications The 41xxx Series Adapters support a variety of cables and optical modules that comply with SFF8024. Specific form factor compliance is as follows:

SFPs:

SFF8472 (for memory map)

SFF8419 or SFF8431 (low speed signals and power)

Optical modules electrical input/output, active copper cables (ACC), and active optical cables (AOC):

10GSFF8431 limiting interface

25GIEEE 802.3by Annex 109B (25GAUI) (does not support RS-FEC)

BCables and Optical Modules Tested Cables and Optical Modules

293 AH0054602-00 M

Tested Cables and Optical Modules Marvell does not guarantee that every cable or optical module that satisfies the compliance requirements will operate with the 41xxx Series Adapters. Marvell has tested the components listed in Table B-1 and presents this list for your convenience.

Table B-1. Tested Cables and Optical Modules

Speed/Form Factor

Manufac- turer Part Number Type Cable

Lengtha Gauge

Cables

10G DACb

Brocade

1539W SFP+10G-to-SFP+10G 1 26

V239T SFP+10G-to-SFP+10G 3 26

48V40 SFP+10G-to-SFP+10G 5 26

Cisco

H606N SFP+10G-to-SFP+10G 1 26

K591N SFP+10G-to-SFP+10G 3 26

G849N SFP+10G-to-SFP+10G 5 26

Dell

V250M SFP+10G-to-SFP+10G 1 26

53HVN SFP+10G-to-SFP+10G 3 26

358VV SFP+10G-to-SFP+10G 5 26

407-BBBK SFP+10G-to-SFP+10G 1 30

407-BBBI SFP+10G-to-SFP+10G 3 26

407-BBBP SFP+10G-to-SFP+10G 5 26

25G DAC

Amphenol

NDCCGF0001 SFP28-25G-to-SFP28-25G 1 30

NDCCGF0003 SFP28-25G-to-SFP28-25G 3 30

NDCCGJ0003 SFP28-25G-to-SFP28-25G 3 26

NDCCGJ0005 SFP28-25G-to-SFP28-25G 5 26

Dell

2JVDD SFP28-25G-to-SFP28-25G 1 26

D0R73 SFP28-25G-to-SFP28-25G 2 26

OVXFJY SFP28-25G-to-SFP28-25G 3 26

9X8JP SFP28-25G-to-SFP28-25G 5 26

BCables and Optical Modules Tested Cables and Optical Modules

294 AH0054602-00 M

40G Copper QSFP Splitter (4 10G)

Dell

TCPM2 QSFP+40G-to-4xSFP+10G 1 30

27GG5 QSFP+40G-to-4xSFP+10G 3 30

P8T4W QSFP+40G-to-4xSFP+10G 5 26

1G Copper RJ45 Transceiver

Dell

8T47V SFP+ to 1G RJ 1G RJ45 N/A

XK1M7 SFP+ to 1G RJ 1G RJ45 N/A

XTY28 SFP+ to 1G RJ 1G RJ45 N/A

10G Copper RJ45 Transceiver

Dell PGYJT SFP+ to 10G RJ 10G RJ45 N/A

40G DAC Splitter (4 10G)

Dell

470-AAVO QSFP+40G-to-4xSFP+10G 1 26

470-AAXG QSFP+40G-to-4xSFP+10G 3 26

470-AAXH QSFP+40G-to-4xSFP+10G 5 26

100G DAC Splitter (4 25G)

Amphenol

NDAQGJ-0001 QSFP28-100G-to- 4xSFP28-25G

1 26

NDAQGF-0002 QSFP28-100G-to- 4xSFP28-25G

2 30

NDAQGF-0003 QSFP28-100G-to- 4xSFP28-25G

3 30

NDAQGJ-0005 QSFP28-100G-to- 4xSFP28-25G

5 26

Dell

026FN3 Rev A00 QSFP28-100G-to- 4XSFP28-25G

1 26

0YFNDD Rev A00 QSFP28-100G-to- 4XSFP28-25G

2 26

07R9N9 Rev A00 QSFP28-100G-to- 4XSFP28-25G

3 26

FCI 10130795-4050LF QSFP28-100G-to- 4XSFP28-25G

5 26

Table B-1. Tested Cables and Optical Modules (Continued)

Speed/Form Factor

Manufac- turer Part Number Type Cable

Lengtha Gauge

BCables and Optical Modules Tested Cables and Optical Modules

295 AH0054602-00 M

Optical Solutions

10G Optical Transceiver

Avago AFBR-703SMZ SFP+ SR N/A N/A

AFBR-701SDZ SFP+ LR N/A N/A

Dell

Y3KJN SFP+ SR 1G/10G N/A

WTRD1 SFP+ SR 10G N/A

3G84K SFP+ SR 10G N/A

RN84N SFP+ SR 10G-LR N/A

Finisar

FTLX8571D3BCL- QL

SFP+ SR N/A N/A

FTLX1471D3BCL- QL

SFP+ LR N/A N/A

25G Optical Transceiver

Dell P7D7R SFP28 Optical Transceiver SR

25G SR N/A

Finisar FTLF8536P4BCL SFP28 Optical Transceiver

SR N/A N/A

FTLF8538P4BCL SFP28 Optical Transceiver SR no FEC

N/A N/A

10/25G Dual Rate Transceiver

Dell M14MK SFP28 N/A N/A

Table B-1. Tested Cables and Optical Modules (Continued)

Speed/Form Factor

Manufac- turer Part Number Type Cable

Lengtha Gauge

BCables and Optical Modules Tested Cables and Optical Modules

296 AH0054602-00 M

10G AOCc Dell

470-ABLV SFP+ AOC 2 N/A

470-ABLZ SFP+ AOC 3 N/A

470-ABLT SFP+ AOC 5 N/A

470-ABML SFP+ AOC 7 N/A

470-ABLU SFP+ AOC 10 N/A

470-ABMD SFP+ AOC 15 N/A

470-ABMJ SFP+ AOC 20 N/A

YJF03 SFP+ AOC 2 N/A

P9GND SFP+ AOC 3 N/A

T1KCN SFP+ AOC 5 N/A

1DXKP SFP+ AOC 7 N/A

MT7R2 SFP+ AOC 10 N/A

K0T7R SFP+ AOC 15 N/A

W5G04 SFP+ AOC 20 N/A

25G AOC

Dell X5DH4 SFP28 AOC 20 N/A

InnoLight TF-PY003-N00 SFP28 AOC 3 N/A

TF-PY020-N00 SFP28 AOC 20 N/A

a Cable length is indicated in meters.

b DAC is direct attach cable.

c AOC is active optical cable.

Table B-1. Tested Cables and Optical Modules (Continued)

Speed/Form Factor

Manufac- turer Part Number Type Cable

Lengtha Gauge

BCables and Optical Modules Tested Switches

297 AH0054602-00 M

Tested Switches Table B-2 lists the switches that have been tested for interoperability with the 41xxx Series Adapters. This list is based on switches that are available at the time of product release, and is subject to change over time as new switches enter the market or are discontinued.

Table B-2. Switches Tested for Interoperability

Manufacturer Ethernet Switch Model

Arista 7060X 7160

Cisco

Nexus 3132 Nexus 3232C Nexus 5548 Nexus 5596T Nexus 6000

Dell EMC S6100 Z9100

HPE FlexFabric 5950

Mellanox SN2410 SN2700

298 AH0054602-00 M

C Dell Z9100 Switch Configuration

The 41xxx Series Adapters support connections with the Dell Z9100 Ethernet Switch. However, until the auto-negotiation process is standardized, the switch must be explicitly configured to connect to the adapter at 25Gbps.

To configure a Dell Z9100 switch port to connect to the 41xxx Series Adapter at 25Gbps: 1. Establish a serial port connection between your management workstation

and the switch.

2. Open a command line session, and then log in to the switch as follows: Login: admin Password: admin

3. Enable configuration of the switch port: Dell> enable Password: xxxxxx Dell# config

4. Identify the module and port to be configured. The following example uses module 1, port 5: Dell(conf)#stack-unit 1 port 5 ? portmode Set portmode for a module Dell(conf)#stack-unit 1 port 5 portmode ? dual Enable dual mode quad Enable quad mode single Enable single mode Dell(conf)#stack-unit 1 port 5 portmode quad ? speed Each port speed in quad mode Dell(conf)#stack-unit 1 port 5 portmode quad speed ? 10G Quad port mode with 10G speed

CDell Z9100 Switch Configuration

299 AH0054602-00 M

25G Quad port mode with 25G speed Dell(conf)#stack-unit 1 port 5 portmode quad speed 25G For information about changing the adapter link speed, see Testing Network Connectivity on page 288.

5. Verify that the port is operating at 25Gbps: Dell# Dell#show running-config | grep "port 5" stack-unit 1 port 5 portmode quad speed 25G

6. To disable auto-negotiation on switch port 5, follow these steps:

a. Identify the switch port interface (module 1, port 5, interface 1) and confirm the auto-negotiation status: Dell(conf)#interface tw 1/5/1 Dell(conf-if-tf-1/5/1)#intf-type cr4 ? autoneg Enable autoneg

b. Disable auto-negotiation: Dell(conf-if-tf-1/5/1)#no intf-type cr4 autoneg

c. Verify that auto-negotiation is disabled. Dell(conf-if-tf-1/5/1)#do show run interface tw 1/5/1 ! interface twentyFiveGigE 1/5/1 no ip address mtu 9416 switchport flowcontrol rx on tx on no shutdown no intf-type cr4 autoneg

For more information about configuring the Dell Z9100 switch, refer to the Dell Z9100 Switch Configuration Guide on the Dell Support Web site:

support.dell.com

300 AH0054602-00 M

D Feature Constraints

This appendix provides information about feature constraints implemented in the current release.

These feature coexistence constraints may be removed in a future release. At that time, you should be able to use the feature combinations without any additional configuration steps beyond what would be usually required to enable the features.

Concurrent FCoE and iSCSI Is Not Supported on the Same Port in NPAR Mode The device does not support configuration of both FCoE-Offload and iSCSI-Offload on the same port when in NPAR Mode. FCoE-Offload is supported on the second physical function (PF) and iSCSI-Offload is supported on the third PF in NPAR mode. The device does support configuration of both FCoE-Offload and iSCSI-Offload on the same port when in single Ethernet PF DEFAULT Mode. Not all devices support FCoE-Offload and iSCSI-Offload.

After a PF with either an iSCSI or FCoE personality has been configured on a port using either HII or Marvell management tools, configuration of the storage protocol on another PF is disallowed by those management tools.

Because storage personality is disabled by default, only the personality that has been configured using HII or Marvell management tools is written in NVRAM configuration. When this limitation is removed, users can configure additional PFs on the same port for storage in NPAR Mode.

Concurrent RoCE and iWARP Is Not Supported on the Same Physical Function RoCE and iWARP are not supported on the same PF. The UEFI HII and Marvell management tools allow users to configure both concurrently, but the RoCE functionality takes precedence over the iWARP functionality in this case, unless overridden by the in-OS driver settings.

DFeature Constraints

301 AH0054602-00 M

NIC and SAN Boot to Base Is Supported Only on Select PFs Ethernet (such as software iSCSI remote boot) and PXE boot are currently supported only on the first Ethernet PF of a physical port. In NPAR Mode configuration, the first Ethernet PF (that is, not the other Ethernet PFs) supports Ethernet (such as software iSCSI remote boot) and PXE boot. Not all devices support FCoE-Offload and iSCSI-Offload.

When the Virtualization or Multi-Function Mode is set to NPAR, FCoE-Offload boot is supported on the second PF of a physical port, iSCSI-Offload boot is supported on the third PF of a physical port, and Ethernet (such as software iSCSI) and PXE boot are supported on the first PF of a physical port.

iSCSI and FCoE boot is limited to a single target per boot session.

Only one boot mode is allowed per physical port.

iSCSI-Offload and FCoE-Offload boot is only supported in NPAR mode.

302 AH0054602-00 M

E Revision History

Document Revision History Revision A, April 28, 2017

Revision B, August 24, 2017

Revision C, October 1, 2017

Revision D, January 24, 2018

Revision E, March 15, 2018

Revision F, April 19, 2018

Revision G, May 22, 2018

Revision H, August 23, 2018

Revision J, January 23, 2019

Revision K, July 2, 2019

Revision L, July 3, 2019

Revision M, October 16, 2019

Changes Sections Affected

Added the following adapters to the list of Marvell products: QL41164HFRJ-DE, QL41164HFRJ-DE, QL41164HFCU-DE, QL41232HMKR-DE, QL41262HMKR-DE, QL41232HFCU-DE, QL41232HLCU-DE, QL41132HFRJ-DE, QL41132HLRJ-DE, QL41132HQRJ-DE, QL41232HQCU-DE, QL41132HQCU-DE, QL41154HQRJ-DE, QL41154HQCU-DE

Supported Products on page xvi

Added support for VMDirectPath I/O. Features on page 1

In Table 2-2, updated the supported OSs for Win- dows Server, RHEL, SLES, XenServer.

System Requirements on page 4

ERevision History

303 AH0054602-00 M

In the bullets following the second paragraph, added text to further describe Dell iSCSI HW and SW installation.

iSCSI Preboot Configuration on page 68

Moved section to be closer to other relevant sec- tions.

Configuring the Storage Target on page 71

In the first paragraph, corrected the first sentence to The Boot Mode option is listed under NIC Configuration Added instructions for setting UEFI iSCSI HBA.

Selecting the iSCSI UEFI Boot Protocol on page 72

Removed sections Configuring iSCSI Boot Parameters and Configuring BIOS Boot Mode.

Boot from SAN Configuration on page 67

Added a reference to Application Note, Enabling Storage Offloads on Dell and Marvell FastLinQ 41000 Series Adapters.

FCoE Support on page 37, iSCSI Support on page 37, Configuring FCoE Boot on page 55,Configuring iSCSI Boot on page 56, Boot from SAN Configuration on page 67, iSCSI Configuration on page 200, FCoE Configuration on page 213

In Step 3, clarified how the RoCE v1 Priority values are used.

Configuring Data Center Bridging on page 53

At the end of the section, added a NOTE with an example of how to install iSCSI BFS in Linux with an MPIO configuration and a single path active.

Configuring iSCSI Boot from SAN for RHEL 7.5 and Later on page 95

Updated the steps for slipstreaming adapter driv- ers into Windows image files.

Injecting (Slipstreaming) Adapter Drivers into Win- dows Image Files on page 122

Removed the bullet stating that RoCE does not work over a VF in an SR-IOV environment. VF RDMA is now supported.

Planning for RoCE on page 128

In Table 7-1, Removed RHEL 7.5; added RHEL 7.7. For RHEL7.6, added support for OFED-4.17-1 GA. Removed SLES 12 SP3; added SLES 12 SP4. Separated SLES 15 (SP0) and SLES 15 SP1; in SLES 15 SP1, added support for OFED-4.17-1 GA. CentOS 7.6: added support for OFED-4.17-1 GA.

Supported Operating Systems and OFED on page 127

Added information on configuring RoCE for VF RDMA for Windows and Linux.

Configuring RoCE for SR-IOV VF Devices (VF RDMA) on page 141 Configuring RoCE for SR-IOV VF Devices (VF RDMA)

ERevision History

304 AH0054602-00 M

In Step 1, updated the second and third bullets to the currently supported OSs for SLES 12 and RHEL, respectively.

RoCE v2 Configuration for Linux on page 155

Changed Step 4 part b to Set the RDMA Proto- col Support to RoCE/iWARP or iWARP.

Preparing the Adapter for iWARP on page 177

Removed reference to appendix C; added configuration information.

Configuring the Dell Z9100 Ethernet Switch for RoCE on page 131

Updated list of OSs that support inbox OFED. Before You Begin on page 188

Removed section iWARP RDMA-Core Sup- port on SLES 12 SP3 and OFED 4.8x.

iWARP Configuration on page 177

In the bulleted list following the third para- graph, updated the list of supported OSs (sec- ond bullet).

NVMe-oF Configuration with RDMA on page 235

Clarified Step 4: To enable RDMA through PowerShell, issue the following Windows PowerShell command.

Creating a Hyper-V Virtual Switch with an RDMA NIC on page 253

In Step 2, corrected the last word of the Power- Shell command to -ManagementOS.

Adding a vLAN ID to Host Virtual NIC on page 254

Changed the commands in Step 1, part c. Added an example of ovsdb-server and ovs-vswitchd running with pid. In Step 4, part c, changed the second paragraph, second sentence to The br1 interface is named eth0, ens7; manually configure the static IP through th network device file and assign the same subnet IP to the peer (Host 2 VM).

Configuring VXLAN in Linux on page 247

Changed the PowerShell command for monitoring virtual function traffic on a virtual machine.

Monitoring Traffic Statistics on page 272

Changed the link for more information about con- figuring a cluster witness.

Step 3. Configuring a Cluster Witness on page 277

In the first paragraph, changed the cmdlet to Enable-ClusterS2D.

Step 5. Enabling Storage Spaces Direct on page 278

In Table A-1, in the Link LED section, updated the LED Appearance and Network State columns.

Adapter LEDS on page 291

305 AH0054602-00 M

Glossary

ACPI The Advanced Configuration and Power Interface (ACPI) specification provides an open standard for unified operating system-centric device configuration and power management. The ACPI defines platform-independent interfaces for hardware discovery, configuration, power management, and monitoring. The specifi- cation is central to operating system-directed configuration and Power Management (OSPM), a term used to describe a system implementing ACPI, which therefore removes device manage- ment responsibilities from legacy firmware interfaces.

adapter The board that interfaces between the host system and the target devices. Adapter is synonymous with Host Bus Adapter, host adapter, and board.

adapter port A port on the adapter board.

Advanced Configuration and Power Interface

See ACPI.

bandwidth A measure of the volume of data that can be transmitted at a specific transmission rateA 1Gbps or 2Gbps Fibre Channel port can transmit or receive at nominal rates of 1 or 2Gbps, depending on the device to which it is connected. This corresponds to actual bandwidth values of 106MB and 212MB, respectively.

BAR Base address register. Used to hold memory addresses used by a device, or offsets for port addresses. Typically, memory address BARs must be located in physical RAM while I/O space BARs can reside at any memory address (even beyond physical memory).

base address register See BAR.

basic input output system See BIOS.

BIOS Basic input output system. Typically in Flash PROM, the program (or utility) that serves as an interface between the hardware and the operating system and allows booting from the adapter at startup.

challenge-handshake authentication protocol

See CHAP.

306 AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

CHAP Challenge-handshake authentication protocol (CHAP) is used for remote logon, usually between a client and server or a Web browser and Web server. A challenge/response is a security mecha- nism for verifying the identity of a person or process without revealing a secret password that is shared by the two entities. Also referred to as a three-way handshake.

CNA See Converged Network Adapter.

Converged Network Adapter Marvell Converged Network Adapters support both data networking (TCP/IP) and storage networking (Fibre Channel) traffic on a single I/O adapter using two new technologies: Enhanced Ethernet and Fibre Channel over Ethernet (FCoE).

data center bridging See DCB.

data center bridging exchange See DCBX.

DCB Data center bridging. Provides enhance- ments to existing 802.1 bridge specifica- tions to satisfy the requirements of protocols and applications in the data center. Because existing high-performance data centers typically comprise multiple application-specific networks that run on different link layer technologies (Fibre Channel for storage and Ethernet for network management and LAN connec- tivity), DCB enables 802.1 bridges to be used for the deployment of a converged network where all applications can be run over a single physical infrastructure.

DCBX Data center bridging exchange. A protocol used by DCB devices to exchange config- uration information with directly connected peers. The protocol may also be used for misconfiguration detection and for configu- ration of the peer.

device A target, typically a disk drive. Hardware such as a disk drive, tape drive, printer, or keyboard that is installed in or connected to a system. In Fibre Channel, a target device.

DHCP Dynamic host configuration protocol. Enables computers on an IP network to extract their configuration from servers that have information about the computer only after it is requested.

driver The software that interfaces between the file system and a physical data storage device or network media.

dynamic host configuration protocol See DHCP.

eCore A layer between the OS and the hardware and firmware. It is device-specific and OS-agnostic. When eCore code requires OS services (for example, for memory allocation, PCI configuration space access, and so on) it calls an abstract OS function that is implemented in OS-specific layers. eCore flows may be driven by the hardware (for example, by an interrupt) or by the OS-specific portion of the driver (for example, loading and unloading the load and unload).

307 AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

EEE Energy-efficient Ethernet. A set of enhancements to the twisted-pair and backplane Ethernet family of computer networking standards that allows for less power consumption during periods of low data activity. The intention was to reduce power consumption by 50 percent or more, while retaining full compatibility with existing equipment. The Institute of Electrical and Electronics Engineers (IEEE), through the IEEE 802.3az task force, developed the standard.

EFI Extensible firmware interface. A specifica- tion that defines a software interface between an operating system and platform firmware. EFI is a replacement for the older BIOS firmware interface present in all IBM PC-compatible personal computers.

energy-efficient Ethernet See EEE.

enhanced transmission selection See ETS.

Ethernet The most widely used LAN technology that transmits information between computers, typically at speeds of 10 and 100 million bits per second (Mbps).

ETS Enhanced transmission selection. A standard that specifies the enhancement of transmission selection to support the allocation of bandwidth among traffic classes. When the offered load in a traffic class does not use its allocated bandwidth, enhanced transmission selection allows other traffic classes to use the available bandwidth. The bandwidth-allocation prior- ities coexist with strict priorities. ETS includes managed objects to support bandwidth allocation. For more informa- tion, refer to: http://ieee802.org/1/pages/802.1az.html

extensible firmware interface See EFI.

FCoE Fibre Channel over Ethernet. A new technology defined by the T11 standards body that allows traditional Fibre Channel storage networking traffic to travel over an Ethernet link by encapsulating Fibre Channel frames inside Layer 2 Ethernet frames. For more information, visit www.fcoe.com.

Fibre Channel A high-speed serial interface technology that supports other higher layer protocols such as SCSI and IP.

Fibre Channel over Ethernet See FCoE.

file transfer protocol See FTP.

308 AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

FTP File transfer protocol. A standard network protocol used to transfer files from one host to another host over a TCP-based network, such as the Internet. FTP is required for out-of-band firmware uploads that will complete faster than in-band firmware uploads.

HBA See Host Bus Adapter.

HII Human interface infrastructure. A specifi- cation (part of UEFI 2.1) for managing user input, localized strings, fonts, and forms, that allows OEMs to develop graphical interfaces for preboot configuration.

host One or more adapters governed by a single memory or CPU complex.

Host Bus Adapter An adapter that connects a host system (the computer) to other network and storage devices.

human interface infrastructure See HII.

IEEE Institute of Electrical and Electronics Engineers. An international nonprofit organization for the advancement of technology related to electricity.

Internet Protocol See IP.

Internet small computer system interface See iSCSI.

Internet wide area RDMA protocol See iWARP.

IP Internet protocol. A method by which data is sent from one computer to another over the Internet. IP specifies the format of packets, also called datagrams, and the addressing scheme.

IQN iSCSI qualified name. iSCSI node name based on the initiator manufacturer and a unique device name section.

iSCSI Internet small computer system interface. Protocol that encapsulates data into IP packets to send over Ethernet connec- tions.

iSCSI qualified name See IQN.

iWARP Internet wide area RDMA protocol. A networking protocol that implements RDMA for efficient data transfer over IP networks. iWARP is designed for multiple environments, including LANs, storage networks, data center networks, and WANs.

jumbo frames Large IP frames used in high-performance networks to increase performance over long distances. Jumbo frames generally means 9,000 bytes for Gigabit Ethernet, but can refer to anything over the IP MTU, which is 1,500 bytes on an Ethernet.

large send offload See LSO.

309 AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

Layer 2 Refers to the data link layer of the multilay- ered communication model, Open Systems Interconnection (OSI). The function of the data link layer is to move data across the physical links in a network, where a switch redirects data messages at the Layer 2 level using the destination MAC address to determine the message destination.

Link Layer Discovery Protocol See LLDP.

LLDP A vendor-neutral Layer 2 protocol that allows a network device to advertise its identity and capabilities on the local network. This protocol supersedes propri- etary protocols like Cisco Discovery Protocol, Extreme Discovery Protocol, and Nortel Discovery Protocol (also known as SONMP). Information gathered with LLDP is stored in the device and can be queried using SNMP. The topology of a LLDP-enabled network can be discovered by crawling the hosts and querying this database.

LSO Large send offload. LSO Ethernet adapter feature that allows the TCP\IP network stack to build a large (up to 64KB) TCP message before sending it to the adapter. The adapter hardware segments the message into smaller data packets (frames) that can be sent over the wire: up to 1,500 bytes for standard Ethernet frames and up to 9,000 bytes for jumbo Ethernet frames. The segmentation process frees up the server CPU from having to segment large TCP messages into smaller packets that will fit inside the supported frame size.

maximum transmission unit See MTU.

message signaled interrupts See MSI, MSI-X.

MSI, MSI-X Message signaled interrupts. One of two PCI-defined extensions to support message signaled interrupts (MSIs), in PCI 2.2 and later and PCI Express. MSIs are an alternative way of generating an interrupt through special messages that allow emulation of a pin assertion or deassertion. MSI-X (defined in PCI 3.0) allows a device to allocate any number of interrupts between 1 and 2,048 and gives each inter- rupt separate data and address registers. Optional features in MSI (64-bit addressing and interrupt masking) are mandatory with MSI-X.

MTU Maximum transmission unit. Refers to the size (in bytes) of the largest packet (IP datagram) that a specified layer of a communications protocol can transfer.

network interface card See NIC.

NIC Network interface card. Computer card installed to enable a dedicated network connection.

NIC partitioning See NPAR.

non-volatile random access memory See NVRAM.

non-volatile memory express See NVMe.

310 AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

NPAR NIC partitioning. The division of a single NIC port into multiple physical functions or partitions, each with a user-configurable bandwidth and personality (interface type). Personalities include NIC, FCoE, and iSCSI.

NVRAM Non-volatile random access memory. A type of memory that retains data (configu- ration settings) even when power is removed. You can manually configure NVRAM settings or restore them from a file.

NVMe A storage access method designed for sold-state drives (SSDs).

OFED OpenFabrics Enterprise Distribution. An open source software for RDMA and kernel bypass applications.

PCI Peripheral component interface. A 32-bit local bus specification introduced by Intel.

PCI Express (PCIe) A third-generation I/O standard that allows enhanced Ethernet network performance beyond that of the older peripheral compo- nent interconnect (PCI) and PCI extended (PCI-X) desktop and server slots.

QoS Quality of service. Refers to the methods used to prevent bottlenecks and ensure business continuity when transmitting data over virtual ports by setting priorities and allocating bandwidth.

quality of service See QoS.

PF Physical function.

RDMA Remote direct memory access. The ability for one node to write directly to the memory of another (with address and size semantics) over a network. This capability is an important feature of VI networks.

reduced instruction set computer See RISC.

remote direct memory access See RDMA.

RISC Reduced instruction set computer. A computer microprocessor that performs fewer types of computer instructions, thereby operating at higher speeds.

RDMA over Converged Ethernet See RoCE.

RoCE RDMA over Converged Ethernet. A network protocol that allows remote direct memory access (RDMA) over a converged or a non-converged Ethernet network. RoCE is a link layer protocol that allows communication between any two hosts in the same Ethernet broadcast domain.

311 AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

SCSI Small computer system interface. A high-speed interface used to connect devices, such as hard drives, CD drives, printers, and scanners, to a computer. The SCSI can connect many devices using a single controller. Each device is accessed by an individual identification number on the SCSI controller bus.

SerDes Serializer/deserializer. A pair of functional blocks commonly used in high-speed communications to compensate for limited input/output. These blocks convert data between serial data and parallel interfaces in each direction.

serializer/deserializer See SerDes.

single root input/output virtualization See SR-IOV.

small computer system interface See SCSI.

SR-IOV Single root input/output virtualization. A specification by the PCI SIG that enables a single PCIe device to appear as multiple, separate physical PCIe devices. SR-IOV permits isolation of PCIe resources for performance, interoperability, and manageability.

target The storage-device endpoint of a SCSI session. Initiators request data from targets. Targets are typically disk-drives, tape-drives, or other media devices. Typically a SCSI peripheral device is the target but an adapter may, in some cases, be a target. A target can contain many LUNs.

A target is a device that responds to a requested by an initiator (the host system). Peripherals are targets, but for some commands (for example, a SCSI COPY command), the peripheral may act as an initiator.

TCP Transmission control protocol. A set of rules to send data in packets over the Internet protocol.

TCP/IP Transmission control protocol/Internet protocol. Basic communication language of the Internet.

TLV Type-length-value. Optional information that may be encoded as an element inside of the protocol. The type and length fields are fixed in size (typically 14 bytes), and the value field is of variable size. These fields are used as follows: TypeA numeric code that indicates

the kind of field that this part of the message represents.

LengthThe size of the value field (typically in bytes).

ValueVariable-sized set of bytes that contains data for this part of the message.

transmission control protocol See TCP.

transmission control protocol/Internet protocol

See TCP/IP.

type-length-value See TLV.

312 AH0054602-00 M

Users GuideConverged Network Adapters 41xxx Series

UDP User datagram protocol. A connectionless transport protocol without any guarantee of packet sequence or delivery. It functions directly on top of IP.

UEFI Unified extensible firmware interface. A specification detailing an interface that helps hand off control of the system for the preboot environment (that is, after the system is powered on, but before the operating system starts) to an operating system, such as Windows or Linux. UEFI provides a clean interface between operating systems and platform firmware at boot time, and supports an architec- ture-independent mechanism for initial- izing add-in cards.

unified extensible firmware interface See UEFI.

user datagram protocol See UDP.

VF Virtual function.

VI Virtual interface. An initiative for remote direct memory access across Fibre Channel and other communication proto- cols. Used in clustering and messaging.

virtual interface See VI.

virtual logical area network See vLAN.

virtual machine See VM.

virtual port See vPort.

vLAN Virtual logical area network (LAN). A group of hosts with a common set of require- ments that communicate as if they were attached to the same wire, regardless of their physical location. Although a vLAN has the same attributes as a physical LAN, it allows for end stations to be grouped together even if they are not located on the same LAN segment. vLANs enable network reconfiguration through software, instead of physically relocating devices.

VM Virtual machine. A software implementa- tion of a machine (computer) that executes programs like a real machine.

vPort Virtual port. Port number or service name associated with one or more virtual servers. A virtual port number should be the same TCP or UDP port number to which client programs expect to connect.

wake on LAN See WoL.

WoL Wake on LAN. An Ethernet computer networking standard that allows a computer to be remotely switched on or awakened by a network message sent usually by a simple program executed on another computer on the network.

Manualsnet FAQs

If you want to find out how the Marvell Dell works, you can view and download the Dell Marvell QLogic 41xxx Adapter User's Guide on the Manualsnet website.

Yes, we have the User's Guide for Dell Marvell as well as other Dell manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Guide should include all the details that are needed to use a Dell Marvell. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Dell Marvell QLogic 41xxx Adapter User's Guide is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Dell Marvell QLogic 41xxx Adapter User's Guide consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Dell Marvell QLogic 41xxx Adapter User's Guide free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Dell Marvell QLogic 41xxx Adapter User's Guide, simply download the document to your computer. Once downloaded, open the PDF file and print the Dell Marvell QLogic 41xxx Adapter User's Guide as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.