Clarke 6013008 CI400 Power Inverter Instructions PDF

1 of 6
1 of 6

Summary of Content for Clarke 6013008 CI400 Power Inverter Instructions PDF

0706

MODEL Nos: CI-200 CI-400 CI-600 CI-800 CI-1000 CI-1500

OPERATION & MAINTENANCE INSTRUCTIONS

12VDC TO 230VAC INVERTERS

-1- -10-

PLEASE NOTE:

THERE ARE NO USER SERVICEABLE COMPONENTS

WITHIN THIS PRODUCT

THIS PRODUCT EMPLOYS MOSFET TECHNOLOGY,

AND CARE MUST BE TAKEN TO AVOID SUBJECTING

COMPONENTS TO A STATIC CHARGE - WHEN

SERVICING ETC., AS THIS COULD CAUSE

IRREPARABLE DAMAGE.

8. TROUBLESHOOTING

FAULT POSSIBLE CAUSE REMEDY No AC output - red LED illuminated

DC input below 10Volts Recharge or replace battery Excessive load - thermal shutdown

Reduce load - wait for inverter to cool. Turn Off, then turn On

No AC output Inverter cold Disconnect load from inverter. Operate inverter without load for a few minutes. Reconnect load.

No AC output - Green LED not illuminated

Inverter fuse blown Remove fuses from their holders and replace with those of the same type and rating

Low battery alarm sounds continuously

Bad wiring connections Tighten all DC connections

Low battery alarm sounds Low battery voltage Recharge battery

Remove load from inverter and recharge battery

Motorised power tool wont start

Excessive start-up load If appliance does not start, then appliance is drawing excessive wattage and will not work with inverter

-9-

Keep inverter and antenna distant from each other. Use shielded antenna cable. Connect antenna to amplifier

Television/Radio interference

Snow in picture, buzz in speaker

9. FUSE REPLACEMENT

If the external fuse blows, then there is most likely a short or overload in the DC wiring. Find and fix the problem before replacing the fuses. After fuse replacement, reconnect the inverter, if fuse continues to blow, contact your Clarke dealer, or telephone Clarke International on 020 8998 7400.

This power inverter is equipped with an external fuse. Normally, this fuse will not blow unless there is a serious problem inside the unit. DO NOT open the unit, there are no user serviceable parts inside the unit.

Motorised power tool does not operate at correct speed

Purely inductive load Make the load not purely inductive. Operate an incandescent lamp at same time as motor, ensuring the combined load does not exceed that of the inverter.

Thank you for purchasing this CLARKE Power Inverter.

Before attempting to use the Inverter, please read this manual thoroughly and follow the instructions carefully. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to the machine giving you long and satisfactory service.

Specifications Model No Part No Power

CI-200 ...................................... 6013005 ................................. 100 watt

CI-400 ...................................... 6013008 ................................. 200 watt

CI-600 ...................................... 6013010 ................................. 300 watt

CI-800 ...................................... 6013015 ................................. 400 watt

CI-1000 .................................... 6013020 ................................. 500 watt

CI-1500 .................................... 6013025 ................................. 750 watt

Output Connection: Standard Receptacles

Output Voltage: AC (RMS)

Output Waveform: Modified Sine Wave

Input Voltage Range: 11 to 15 VDC

Low Voltage Alarm: approx. 10.5 VDC

Low Voltage Shutdown: approx.10.0 VDC

Input Cables: Cigarette Lighter Plug (up to 150 watts) Battery Clip Cable

Additional Protection: Overload, Over voltage, Over temp.

CLARKE GUARANTEE This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt as proof of purchase.

This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended.

Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission.

This guarantee does not effect your statutory rights.

Waste electrical products should not be disposed of with household waste. Please dispose of at your local recycling facility

-2-

Please note that the details and specifications contained herein, are correct at the time of going to print. However, CLARKE International reserve the right to change specifications at any time without prior notice.

Safety Precautions

WARNING: To ensure reliable service from your power inverter, you must ensure it is installed and used according to these operator instructions, please read these instructions

thoroughly before attempting to use the inverter.

Pay particular attention to the WARNING and CAUTION statements in this manual.

CAUTION statements advise against certain conditions and practises that could result in damage to your inverter.

WARNING statements identify conditions or practises that could result in personal injury.

CAUTIONS

1. DO NOT use with positive earth systems (the majority of modern vehicless, lorries, boats etc., are negative earth). Reverse polarity connection will result in a blown fuse and may cause permanent damage to the inverter.

2. This inverter will not operate high wattage appliances. 3. DO NOT use if it is wet. 4. DO NOT install inside the engine compartment - inverter MUST be installed in a well

ventilated area. 5. This inverter is not tested for use with medical devices.

WARNINGS

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION OR INJURY:

1. DO NOT connect to an AC supply. 2. Before making adjustment etc., to the appliance being run by the inverter, ALWAYS

disconnect the appliance from the inverter beforehand. 3. DO NOT make or break any electrical connections in explosive areas such as garage

forecourts etc. This applies to all types of connection including cigarette lighter type plugs.

IMPORTANT CABLE INFORMATION

Attention must be paid to the cable used between the appliance and the inverter. It must be of the correct diameter and length, otherwise power loss or reduced operating time may occur. Marine installations are also subjected to vibration and stresses that exceed those of other mobile installations. Therefore ensure all connections are tight, water resistant and have suitable strain relief for DC cables etc. Cable installation must be the correct type for the environment.

-3-

6. PROTECTION FEATURES OF INVERTER

Your inverter monitors the following potentially hazardous conditions:

Low Battery Voltage - This condition is not harmful to the inverter but could damage the power source. An audible alarm will sound when input voltage drops to 10.5 volts. The inverter automatically shuts down when input voltage drops to 10.0 volts. When the condition is rectified, the unit may be restarted.

Over Voltage Protection - The inverter will automatically shut down when the input voltage exceeds 15 volts DC.

Short Circuit Protection - The inverter will shut down. Remove the short circuit and inverter will auto reset.

Overload Protection - The inverter will automatically shut down when the continuous draw exceeds the specified watts.

Thermal Overload Protection - When the temperature sensor reaches 65OC (150OF), the unit will automatically shut down. Allow the unit to cool for at least 15 minutes before attempting to restart. Unplug unit while cooling.

Low Battery Alarm - An alarm will sound when the voltage from the battery drops to 10.5 volts. The user should stop operation of the appliance at this time since the inverter will shut down automatically shortly thereafter, when the battery voltage drops to 10 volts. Start your engine to recharge the battery.

If the low voltage alarm sounds when the battery is fully charged, follow the steps for solving lack of output power in the Troubleshooting Guide.

The alarm will sound when the inverter is overloaded, in thermal shutdown, or if there is an excessive voltage drop between the battery and inverter.

7. COMMON PROBLEMS

Buzzing sound in audio systems:

Some inexpensive stereo systems and boom boxes emit a buzzing sound from their speakers when operated from the inverter. This occurs because the power supply in the electronic device does not adequately filter the modified sine wave produced by the inverter. The only solution to this problem is to use a higher quality sound system that incorporates a higher quality power amplified supply.

Television Interference:

The inverter is shielded to minimize interference with TV signals. However, in some instances, some interference may still be visible, particularly with weak TV signals. Try the following corrective measures:

-8-

Position the inverter as far as possible from the television, the antenna and the antenna cables. Use an extension cable, if necessary

Adjust the orientation of the inverter, the antenna cables and the TV power cord to minimize interference

Make sure that the antenna feeding the television provides an adequate (snow free) signal and that high quality, shielded antenna cable is used.

4.4. Placement of the Inverter For best operating results, the inverter should be placed on a flat level surface. 3 feet (1.0 meter) cables are provided allowing for easy positioning of the inverter. The inverter should only be used in locations that meet the following criteria:

DRY - Do not allow water and/or other liquids to come into contact with the inverter.

COOL - Ambient air temperature should be between -1OC (30O F) and 40OC, (105OF). Do not place the inverter on or near a heating vent or any piece of equipment which is generating heat. Keep the inverter away from direct sunlight.

VENTILATED - Keep the area surrounding the inverter clear to ensure free air circulation around the unit. Do not place items on or over the inverter during operation. A fan is helpful if the inverter is operating at maximum power outputs for extended periods of time. The unit will shut down if the internal temperature exceeds 65OC. The unit will restart after it cools.

SAFE - Do not use the inverter near flammable materials or in locations that may accumulate flammable fumes or gases.

5. OPERATING TIPS

5.1. Rated Versus Actual Current Draw of Equipment Most electrical tools, appliances and audio/video equipment have labels that indicate the power consumption in watts. Be sure that the power consumption of the appliance you wish to operate is rated at the specified wattage, or less.

The inverter is provided with thermal overload protection. If the temperature increases to 60OC, the buzzer will sound for 1 minute, then the unit will shut down, when the temperature reaches 65OC. It will restart once the temperature drops sufficiently. Investigate the cause of the overload and rectify before restarting the appliance.

Resistive loads are the easiest for the inverter to run. However, larger resistive loads, such as electric stoves or heaters, usually require more power than the inverter can deliver on a continuous basis. Inductive loads, such as TVs and stereos, require more current to operate than do resistive loads of the same wattage rating. Induction motors, as well as some televisions, may require 2 to 6 times their wattage rating to start up. The most demanding in this category are those that start under load, such as compressors and pumps. Testing is the only definitive way to determine whether a specific load can be started and how long it can run. The unit will simply shut down if it is overloaded. To restart the unit after a shutdown due to overloading, disconnect the load and if necessary turn the power switch OFF then ON.

CAUTION: This inverter will not operate high wattage appliances.

5.2. Battery Operating Time Battery operating time depends upon how much is drawn to operate the particular appliance. A 120 ampere hour battery for example, can, theoretically, provide 40 amps for a period of 3 hours. However, we recommend that the battery be charged (start the engine) regularly in order to maintain sufficient output. This will guard against any unexpected shutdown of the equipment and will ensure that there is always sufficient battery capacity to start the vehicles engine. The inverter will sound its alarm when DC voltage drops to 10.5V.

The inverter may be used whether or not the vehicles engine is running. However, the inverter may not operate while the engine is starting since the battery voltage can drop substantially during cranking.

In most instances, the inverter can be left connected to the battery when not in use since it draws little current. However if the vehicle is to remain unused for several days, then disconnect it from the battery.0

-7-

1. INTRODUCTION Your new inverter is one in a series of the most advanced DC to AC inverters available today. With proper care and appropriate usage, it will give you years of dependable service in your car, truck, RV or boat.

The inverter supplies continuous 230V, 50Hz power via a standard 3-pin socket whenever and wherever it is required. The inverter is capable of running a range of household appliances, including colour TVs, TV/VCR combinations, laptop computers, camcorders, cellular phone, power tool chargers, lamps etc., depending upon the rating of the converter. Added safety features include automatic shutdown and a low battery alarm - to avoid the possibility of damaging your battery.

2. CONTROLS. INDICATORS AND CONNECTORS Two LEDs are provided on the front panel.

The GREEN LED illuminates when the converter is connected, switched ON, and working correctly.

The RED LED , when illuminated, indicates that the inverter has shutdown - from overload, over voltage or over temperature.

230V Power is provided via a standard 3-pin socket.

An ON/OFF switch turns the inverter circuitry On and Off. The switch is used to force reset the inverter circuits.

The back panel provides DC connectors, either battery clamps or cigar lighter connector.

3. HOW YOUR INVERTER WORKS The inverter converts a 12V direct current - from a battery or other power source, to a 230V 50Hz AC (alternating current) output.

3.1. Principle of Operation The inverter converts power in two stages. The first stage raises the low voltage DC input to high voltage DC. The second stage is the actual inverter stage that converts the high voltage DC into AC. See figure 1.

The inverter stage uses advanced power MOSFET transistors in a full bridge configuration. This ensures excellent overload capability and the ability to operate reactive loads such as lamp ballasts and small induction motors.

Figure 1 Principle of Operation

I2VDC

Input

To AC

Appliance

-8-

I2VDC TO high High voltage DC voltage DC TO AC

CONVERSION CONVERSION

3.2. The Output Waveform The AC output waveform of the inverter is known as modified sine wave. It is a waveform that has characteristics similar to the sine wave shape of utility power. This type of waveform is suitable for most AC loads, but may not be suitable for scientific equipment. Always consult the manufacturers manual where necessary.

Figure 2 Modified sine wave and sine wave comparison

The output from this inverter has an RMS (root mean square) voltage, the same as that found in a normal standard household - 230V. It should be noted, that most AC voltmeters (both digital and analog) are sensitive to the AVERAGE value of the waveform rather than the RMS value, and are calibrated for RMS voltage under the assumption that the waveform measured will be a pure sine wave. These meters, therefore, will not read the RMS voltage of a modified sine wave correctly, and will read about 20 to 30 volts lower than the true voltage, when measuring the output of the inverter.

4. INSTALLATION

4.1. Power Source Requirements The power source must provide between 11 and 15 volts DC and must be able to supply the necessary current to operate the load. The power source may be a battery or a well regulated DC power supply. To obtain a rough estimate of the current (in amperes) the power source must deliver, simply divide the power consumption of the load (in watts AC) by 10.

Example: if a load is rated at 300 watts AC, the power source must be able to deliver: 300 divided by 10 = 30 amperes

CAUTION: the inverter must, be connected only to batteries with a nominal output voltage of 12 volts. The unit will not operate from a 6-volt battery and will sustain permanent damage if connected to a 24-volt battery.

4.2. Connection to Power Source The inverter is provided with a fused cigarette lighter plug and battery cables with clamps for connection to a suitable battery:

CAUTION: Do not use with positive earth electrical systems (The majority of modern vehicles, , and lorries are negative earth).

-5-

Sine Wave Modified Sine Wave

Connecting to source using cigarette lighter plug:

The cigarette lighter plug is suitable for operating the inverter at power outputs up to 150 watts. The tip of the plug is positive and the side contact is negative. Connect the inverter to the power source by inserting the cigarette lighter plug firmly into the cigarette lighter socket of a vehicle or other DC power source.

Connect directly to power source when operating above 150 Watts.

NOTE: Most vehicle cigarette lighter circuits use fuses rated at 15 to 20 Amps or greater. To operate at full power output, either use the battery clamp cable (supplied) or directly wire to the power source with user-supplied wire and fuse.

CAUTION: Reverse polarity connection will result in a blown fuse and may cause permanent damage to the inverter.

Connecting to a Power Source Using Cables Connectors Provided:

If the inverter is to be used for extended periods at power levels above 150 watts, direct connection to the power source is necessary. Use the cables provided to connect the inverter directly to the 12 volt power source using the following guidelines:

1. Check to be sure the inverters power switch is turned OFF and that no flammable fumes are present.

2. Connect the black cable to the black post marked (-) on the back of the inverter. Connect the black battery clip to the negative terminal of the battery.

3. Connect the red cable to the red post marked (+)on the back of the inverter. Connect the red battery clip to the positive terminal of the battery.

4. Check to ensure that all connections between battery clips and terminals are clean and secure.

CAUTION: Loose connectors may cause overheated wires and melted insulation. Check to make sure you have not reversed the polarity.

4.3. Connection to Load With the inverter connected to the power source, but switched OFF, plug the cable, from the appliance you wish to operate, into the AC receptacle on the inverter. Switch ON and the green LED will illuminate to indicate that the inverter is functioning. Make sure the combined load of your equipment does not exceed the rated output of the converter (Watts).

The Inverter is engineered to be connected directly to standard electrical and electronic equipment in the manner described above.

WARNING: DO NOT UNDER ANY CIRCUMSTANCES connect the Inverter to household AC circuits

CAUTION: RECHARGEABLE APPLIANCES

Certain rechargeable devices are designed to be recharged by plugging them directly into an AC receptacle. Do not use the inverter to recharge these devices as they could damage the inverter.

This problem does not occur with the majority of battery operated eq

Manualsnet FAQs

If you want to find out how the 6013008 Clarke works, you can view and download the Clarke 6013008 CI400 Power Inverter Instructions on the Manualsnet website.

Yes, we have the Operating and Maintenance Instructions for Clarke 6013008 as well as other Clarke manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Operating and Maintenance Instructions should include all the details that are needed to use a Clarke 6013008. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Clarke 6013008 CI400 Power Inverter Instructions is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Clarke 6013008 CI400 Power Inverter Instructions consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Clarke 6013008 CI400 Power Inverter Instructions free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Clarke 6013008 CI400 Power Inverter Instructions, simply download the document to your computer. Once downloaded, open the PDF file and print the Clarke 6013008 CI400 Power Inverter Instructions as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.