3 - 1 SUPER DETECTOR MODEL NO: CDM65

PART NO: 45000135

OPERATING INSTRUCTIONS

ORIGINAL INSTRUCTIONS GC0321- Rev 2

P

INTRODUCTION Thank you for purchasing this CLARKE CDM65 Super Detector. Before attempting to use this product, please read these instructions carefully. In doing so you will ensure your safety and you can look forward to your purchase giving you long and satisfactory service.

The CLARKE 3 - 1 super detector is ideal for DIY and Trade use.

GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt which will be required as proof of purchase.

This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for its intended purpose. Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission.

This guarantee does not effect your statutory rights.

FEATURES

Detects metal, studding and AC voltages

Visual and audible warning

Low power consumption

Easy to use

2 arts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

P

OVERVIEW

INSERTING THE BATTERY 1. Remove the battery door on the rear of the unit.

2. Connect a 9V PP3 battery to the battery clip.

3. Place the battery into the compartment.

4. Replace the battery door.

3 arts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

P

AC VOLTAGE DETECTION

1. Set the selector switch to the AC WIRE position.

CALIBRATION 2. Hold the unit in the air away from any metal objects.

3. Press and hold the TEST button.

The unit will beep twice when calibration is complete. Do not release the TEST button.

USING THE UNIT

4. Keep holding the TEST button and place the unit on the wall, slowly move the unit sideways across the wall.

As you approach a live wire, the signal lights will light up sequentially, the buzzer will sound when you reach the edge of the live wire, when this happens mark the point by placing a pencil mark in the grove on top of the unit.

5. Carry on moving the unit in the same direction until all of the signal LEDS go out and then reverse direction.

Once again, mark the point at which the top LED lights up and the buzzer sounds by placing a pencil mark in the grove on top of the unit.

The centre of the live wire is located mid way between the two pencil marks.

4 arts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

P

AC VOLTAGE DETECTION

Notes Some walls containing metal fibres (used in

fireproofing) will cause the detector to register a voltage over a wider area.

Rubbing or banging the wall may generate static electricity, causing a false reading.

Touching a damp wall being tested may also cause a false positive reading.

The unit will not detect wire inside metal shielding or trunking.

5 arts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

P

METAL DETECTION

1. Set the selector switch to the METAL position.

CALIBRATION

2. Hold the unit in the air away from any metal objects.

3. Press and hold the TEST button.

The unit will beep twice when calibration is complete. Do not release the TEST button.

USING THE DETECTOR

4. Keep holding the TEST button and place the unit on the wall, slowly move the unit sideways across the wall.

As you approach a metal object, the signal lights will light up sequentially, the buzzer will sound when you reach the edge of the metal object, when this happens mark the point by placing a pencil mark in the grove on top of the unit.

5. Carry on moving the unit in the same direction until all of the signal LEDS go out and then reverse direction.

Once again, mark the point at which the top LED lights up and the buzzer sounds by placing a pencil mark in the grove on top of the unit.

The centre of the metal object is located mid way between the two pencil marks.

Wearing rings or other hand jewellery may cause a false reading.

6 arts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

P

STUD DETECTION

1. Set the selector switch to the STUD position.

CALIBRATION

2. Place the unit against the wall, press and hold the TEST button.

The unit will beep twice when calibration is complete. Do not release the TEST button.

USING THE DETECTOR

3. Keep holding the TEST button and slowly move the unit sideways across the wall.

The buzzer will sound when you reach the edge of the studding, when this happens mark the point by placing a pencil mark in the grove on top of the unit.

4. Carry on moving the unit in the same direction until all of the signal LEDS go out and then reverse direction.

Once again, mark the point at which the top LED lights up and the buzzer sounds by placing a pencil mark in the grove on top of the unit.

The middle of the studding is located mid way between the two pencil marks.

Always check that the STUDDING that you have detected is not a metal pipe, see page 6.

7 arts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

P

STUD DETECTION

NOTES

You can use the detector on wallpaper, however it may not be effective on some types of foil backed wallpapers.

If the unit is placed over studding during the calibration, the unit will not work, simply re- calibrate the unit 150 mm away from the last place.

The surface of the wall should be dry and flat.

Always keep your free hand away from the wall during detection.

If you release the test button at any time during detection, you will need to carry out the calibration procedure again.

Knots in wood can cause false readings to occur.

Normally, studding is placed at intervals of 40 - 60 cm.

TIPS

Re-calibrate the unit frequently to avoid inaccurate readings.

Take several readings vertically above, below, to the left and right to confirm the reading.

8 arts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

P

DETECTION DEPTHS Iron Pipe (25mm) 30 mm

Studding (30 x 30mm)18 mm

AC Voltage (90-250V @ 50/60 Hz) 50 mm

Detection depth can vary due to moisture content and texture of the wall, paint etc.

END OF LIFE Do not dispose of this product with general household waste. It must be disposed of according to the laws governing Waste Electrical and Electronic equipment, at a recognized disposal facility.

SPECIFICATIONS Battery: 9V, PP3 or equivalent

Weight: 164 g

Dimensions: (H x W x D) 151 x 65 x 31mm

Storage temperature: -20oC to 50oC

Operating temperature: -7oC to 40oC

9 arts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com

P

DECLARATION OF CONFORMITY - UKCA

10 arts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@c

Manualsnet FAQs

If you want to find out how the 4500135 Clarke works, you can view and download the Clarke 4500135 CDM65 3-1 Super Detector Instructions on the Manualsnet website.

Yes, we have the Operating Instructions for Clarke 4500135 as well as other Clarke manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Operating Instructions should include all the details that are needed to use a Clarke 4500135. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Clarke 4500135 CDM65 3-1 Super Detector Instructions is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Clarke 4500135 CDM65 3-1 Super Detector Instructions consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Clarke 4500135 CDM65 3-1 Super Detector Instructions free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Clarke 4500135 CDM65 3-1 Super Detector Instructions, simply download the document to your computer. Once downloaded, open the PDF file and print the Clarke 4500135 CDM65 3-1 Super Detector Instructions as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.