Clarke 6470636 DMD66 Dehumidifier Instructions PDF

1 of 6
1 of 6

Summary of Content for Clarke 6470636 DMD66 Dehumidifier Instructions PDF

0807

MODEL NO: DMD66 PART No: 6470636

DEHUMIDIFIER

OPERATION & MAINTENANCE INSTRUCTIONS

2 11

Please note that the details and specifications contained herein, are correct at the time of going to print. However, CLARKE International reserve the right to change specifications at any time without prior notice.

Do not dispose of with general household waste. It must be disposed of according to law, at a properly recognised disposal facility

Thank you for purchasing this CLARKE Dehumidifier.

Before attempting to use the machine, please read this manual thoroughly and follow the instructions carefully. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to the unit giving you long and satisfactory service.

Specifications Model No: ........................................................................................... DMD 66

Part No: ............................................................................................... 6470645

Voltage: ....................................................... 230 &110/115 Volt 1Phase 50Hz

Fuse Rating: .................... See Product Data Plate (13A-230v & 16A-110v)

Running Current: .................................................. 3.5A (230v) & 7.3A (110v)

Refrigerant: .................................................................................. R417A (R59)

Temperature Range: ...................................................................... 5 to 35C

Weight: ...................................................................................................... 44Kg

Dimensions: ..................................... 770mm (H) x 565mm (W) x 460mm (D)

Max Motor Wattage When Running: ................................................... 820W

Max Extraction Rate: ............................................................. 60 litres (24 hrs)

CLARKE GUARANTEE This CLARKE product is guaranteed against faulty manufacture for a pe- riod of 12 months from the date of purchase. Please keep your receipt as proof of purchase.

This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended.

Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission.

This guarantee does not effect your statutory rights.

The DMD66 is equipped with a manually operated dual voltage selector switch.

The DMD66 is designed for INTERNAL USE ONLY.

Extension leads, if used, should be; correctly rated for the inductive load, fully unwound,

loosely coiled and never run through water or over sharp edges, this applies equally to the

mains lead on the dehumidifier.

3

Parts Diagram

10

Safety Precautions

WARNING: As with all machinery, there are certain hazards involved with their operation and

use. Exercising respect and caution will considerably lessen the risk of personal injury. However, if normal safety precautions are overlooked or ignored, personal

injury to the operator or damage to property, may result.

Care must be taken when handling water near electricity as there is risk of electric

Never use the unit near heaters or other sources of heat.

Never place anything on the top of this unit, and never obstruct the air intake/exhaust grills.

Never pour or spray water on the unit.

Never use solvent cleaners or other flammable liquids to clean the unit.

Never pull out the plug to stop or start the machine. Use the ON/OFF switch on the side of the unit.

Never pull on the mains cable to pull the plug from the socket or to move the machine

WARNING! Read these safety instructions before using the equipment.

Always transport, store and operate this equipment in an upright position DO NOT lay the unit down.

Always leave the unit to stand for 15 minutes minimum before switching on if it has been tilted or moved from an upright position i.e. after transportation or cleaning.

Always allow a gap of 300mm around the unit to allow air to circulate.

Always ensure that the air inlet and outlet areas are clear.

Always remove the mains plug from the mains supply before carrying out any maintenance.

Always switch off, unplug and drain any water from the dehumidifier before moving.

Always switch the electrical supply off and disconnect from the mains, when not in use.

4

Parts List Item Part No Description Qty

1 EL020113 Mains Cable 1 2 EL030103 Push Button Switch 1 3 BW020362 Chassis 1 4 EL030303 Capacitor 1 5 FR010115 Compressor 1 6 FR010404 Solenoid Coil 1 7 FA040210 Fan Assembly 1 8 ME040523 Frame Bung 1 9 BW020370 Upper Case 1 10 ME040520 Saddle Washer 1 11 BW040325 Handle 1 12 BW020359 Front Panel 1 13 BW020363 Transformer Cover 1 14 BW020371 Drip Tray 1 15 EL030602 Transformer 1 16 FR020302 Filter Drier 1 17 ME040129 Right Angle Coupling 1 18 ME040131 Condensate Tube 1 19 EL030511 Hour Clock 1 20 ME040207 Cable Gland 1 21 FI060405 Star Washer 2 22 ME010102 Wheels 2 23 EL030510 Timer 1 24 BW020352 Lower Case 1 25 FR030309 CD/DX Coil 1 26 EL010210 Circuit Breaker 10Amp 1 27 EL030906 Resistor 1 28 EL030123 Voltage Selector Switch 1 29 BW040322 Axle 1

30 EL030209 Switching Relay 1

PARTS & SERVICE TEL: 020 8988 7400 or e-mail as follows:

PARTS: Parts@clarkeinternational.com SERVICE: Service@clarkeinternational.com

9

Electrical Connections The DMD66 is fitted with a Manual Dual Voltage Selection Switch, and can be connected into a standard 16amp 110V, or 13amp 230V supply once the correct plug has been fitted. To reduce the risk of shock, it is recommended to use a suitable RCD (residual current device).

230 Volt Mode

Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply through an ap- proved 13 amp BS 1363 plug, or a suitably fused isolator switch.

WARNING! THIS APPLIANCE MUST BE EARTHED

IMPORTANT: Wires in the mains lead are coloured in accordance with the following code:

Green & Yellow .......... Earth

Blue .............................. Neutral

Brown .......................... Live

As the colours of the flexible lead of this appliance may not correspond with the coloured markings identifying terminals in your plug, or your mains supply, proceed as follows:

Connect GREEN & YELLOW coloured cord to plug terminal marked with a letter E or Earth symbol or coloured GREEN or GREEN & YELLOW.

Connect BROWN cord to terminal marked with a letter L or coloured RED.

Connect BLUE cord to terminal marked with a letter N or coloured BLACK.

Fuse Rating

The fuse in the plug must be replaced with one of the same rating (13amp) and this re- placement must be ASTA approved to BS1362.

110 Volt Mode

These models must be connected to a protected 110V supply, through a suitably ap- proved BS4343/IEC309-2 connector. On no account must a 230V, 13amp (BS1363) plug be used.

NOTE: If a portable 110V transformer is used, make sure it has a rated capacity sufficient to take the load of the unit.

In the event that the unit is hard wired into the electrical system, it must be carried out in accordance with IEE regulations.

WARNING! IF YOU ARE IN ANY DOUBT ABOUT ELECTRICAL CONNECTIONS, CONSULT A

QUALIFIED ELECTRICIAN. NEVER ATTEMPT ELECTRICAL REPAIRS YOURSELF.

5

Troubleshooting If your dehumidifier fails to operate correctly, check the information below before contacting your Clarke dealer for assistance.

Unit fails to operate. Power failure. Check the unit is plugged into the correct power supply & switched ON.

Check breaker. Reset if necessary.

Check plug fuse (13amp). Replace if necessary.

Poor drying performance.

Dehumidifier in automatic defrost mode.

Normal ~ wait 15mins and check drying again.

Clean coils, using compressed air if available.

Remove obstruction, check min clearance around unit, re- site if necessary.

Check the environment temperature ~ if too low, switch unit OFF and add heat to area.

If temp is too high, switch the unit Off and wait for temperature to drop.

Air intake/exhaust grills obstructed.

Temperature outside of specified operating range.

Coils Dirty.

Water leaking. Blocked drain hose.

Water receptacle full and overflowing.

Drain hose higher than the outlet port.

Unit has been moved without draining the inner drip tray.

Unit iced up.

Clear blockage.

Adjust the hose level, check the water flows.

Ensure the drip tray is empty before moving the unit.

Dehumidifier run below min temperature.

Compressor stops running.

Input voltage too low. Check voltage.

Switch the unit OFF, wait 15mins before switching back ON.

Circuit breaker operated due to excess current or temperature.

Check level and empty if required.

8

PROBLEM PROBABLE CAUSE REMEDY

Installation Little installation is required other than siting the dehumidifier on a firm, flat and level surface, selecting the power supply voltage and setting the unit selector switch accordingly, connecting to the main electric supply and choosing the method of disposing of collected water.

Operation Never attempt to use the dehumidifier for anything other than its intended purpose.

The DMD66 is fitted with an electronic hour run counter which is not resettable. Before switching the dehumidifier ON, take a note of the hours run counter to assist with monitoring the amount of time the unit is run.

After moving the dehumidifier into the location to be used, allow the unit to stand for 15 minutes before switching it on.

Ensure all doors and windows are closed and the area sealed where possible, this aids in speeding up the dehumidification/drying process.

Plug the unit into the power supply and switch the supply ON.

Switch the unit ON by depressing the ON/OFF switch marked I/O, I= ON, O=OFF. The ON/ OFF switch is located next to the hour counter.

The dehumidifier is now running, allow a minimum of 10mins for it to begin dehumidifying/ drying.

The water collected can be drained automatically using the hose connected to the drip tray drain. Ensure the hose is kept below the level of the drain, otherwise flooding of the unit will occur.

Drain condensate into a suitable container ( builders bucket or similar). It is important to keep an eye on the water level in the bucket and empty regularly to prevent it from overflowing.

6

Please note, that the drip tray is not removable

Please note also, that it is perfectly safe to locate this model in an area with standing water, provided the water is less that 2 deep.

The voltage selector switch - shown in the illustration opposite, is accessed by removing the bottom rear panel (5 screws) at the rear of the dehumidifier. It is factory set to select 230V.

This equipment is designed to work in temperatures between 5C & 35C, Never operate in temperatures below 5C or above 35C. If the temperature in the room rises above 35C, switch the unit OFF. Failure to switch OFF could cause the compressor to overheat, resulting in premature failure.

If used in temperatures below 5C, the coil may frost up and no water will be produced until the defrost cycle commences.

NOTE: if using an extension lead, ensure it is correctly rated for the inductive load, fully unwound and never run through water or over sharp edges.

Maintenance

ALWAYS disconnect the unit from the power supply before carrying out any maintenance activities. This dehumidifiers is fairly maintenance free, only requiring periodic cleaning. All internal parts are sealed and lubricated for the life of the unit. The cooling coils require cleaning at least once a month, more often if the unit is used in dusty environments.

WARNING FAILURE TO CARRY OUT ROUTINE MAINTENANCE WILL AFFECT HE MACHINE

PERFORMANCE AND RESULTING IN PREMATURE FAILURE, THIS COULD ALSO INVALIDATE THE WARRANTY.

MAINTENANCE ACTIVITIES MUST ALWAYS BE CARRIED OUT BY QUALIFIED PERSONNEL ONLY

7

Remove all 13 cover securing screws and pull off the cover. Clean the inside of the unit by carefully blowing out any dust using compressed air at low pressure. Pay particular attention to the fan blade and motor, ensure the motor spins freely. Reassemble the unit in the reverse order.

IMPORTANT When carrying out maintenance activities, precautions to ensure the safety of yourself and that of others around you must be considered, i.e. choose a location where it is safe to use compressed air to blow the unit out ensuring you wear the necessary safety equipment, especially safety glasses and ear defenders..

Covers removed

THERMAL OVERLOAD The DMD66 transformer is protected with an internal 10 amp resettable circuit breaker - see Illustration opposite. The breaker is accessed by removing the bottom panel (5 screws) at the rear of the dehumidifier. In the event the circuit breaker operates and shuts the unit down, investigate the cause and rectify. Then reset the device, by pushing the button in. Please note also, that if the unit is plugged into a 230V supply, when the changeover switch is set to 110V, the circuit breaker will operate. Re-set as described above, once the changeover switch is set to 230V.

Storage Switch OFF the power supply and disconnect from the main electrical supply by removing the plug from the socket.

The unit should not be moved for at least 15 minutes after switching off. Always ensure the drip tray is clean and dry before storing.

If the storage period is expected to be prolonged, remove the top cover as described above, and blow out the coils and i

Manualsnet FAQs

If you want to find out how the 6470636 Clarke works, you can view and download the Clarke 6470636 DMD66 Dehumidifier Instructions on the Manualsnet website.

Yes, we have the Operation and Maintenance Instructions for Clarke 6470636 as well as other Clarke manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Operation and Maintenance Instructions should include all the details that are needed to use a Clarke 6470636. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Clarke 6470636 DMD66 Dehumidifier Instructions is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Clarke 6470636 DMD66 Dehumidifier Instructions consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Clarke 6470636 DMD66 Dehumidifier Instructions free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Clarke 6470636 DMD66 Dehumidifier Instructions, simply download the document to your computer. Once downloaded, open the PDF file and print the Clarke 6470636 DMD66 Dehumidifier Instructions as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.