Clarke 6470617 CD1150 Dehumidifier Instructions PDF

1 of 6
1 of 6

Summary of Content for Clarke 6470617 CD1150 Dehumidifier Instructions PDF

OPERATING & MAINTENANCE INSTRUCTIONS

DEHUMIDIFIER MODEL NO: CD1150

Part No: 6470617

0905

PARTS DRAWING

2 11

When disposing of this product, ensure it is disposed of in accordance with all local ordinances

E1 Display DFRBDP2

E2 Power DFRBPW2UK

E4 Micro switch 770400090

E5 AC Cables, 540mm, DE/F 757604410

E6 Compressor 740000810

E6B PTC Relay 3799005050

E6C Overload Protector 3745650120

E6G Rubber Grommet 3799100322

E7 NTC Defrost Sensor 768000193

E8 AC Power Cord 757000680

E9 Compressor Power Cord 757600210

EB Fan Motor, 230V 774600631

ED Humidistat 770000150

EE AC Cord for Humidistat 757600350

EK Signal Wire, LED 757604280

EL Signal Wire, Neon 757604290

P1 Front Case 212000510

P2 Rear Case 212000370

P3 Base 212000380

P4 Panel 313600490

P5 Switch Knob 413600450

P6 Panel Plate 413202190

P7 Water Bucket, Purple 711000580

P8 Float 413600460

P9 Handle 311200550

PA Filter Guide 411200560

PB Air Outlet Grid 311200530

PC Water Pan 311000470

PD Water Passage 313600470

PE Air Guide Blade 313600590

PF Fan 746600161

PG Heat Exch. Upper Chassis 311200540

PH Upper Shield 211400450

P1 Middle Shield 211400440

PJ Filter Frame 211400430

PK Filter Frame Cover 211400400

S1 Bolt 4*44 714320408

S2 Bolt 4*10 714400410

S3 Bolt 4*l0 light gray 714400408

S5 Bolt 4*8 714410403

S6 Bolt 35*8 714410302

S8 Bolt 4*l0 714300411

S9 Bolt 3.5*6 714360302

SA Bolt 3*6 714300301

T1 Evaporator 342200370

T2 Condenser 342200440

T3 Discharge Tube 341202890

T4 Suction Tube 341202880

T5 Suction Tube 441203020

T6 Capillary 441202680

T7 Refrigerant Filter 441202380

T8 Filter Connect Tube 441202360

TC Process Tube 441202350

TD Process Tube 441200470

YI Caster 732000010

Y2 Rubber Bush 417400340

Y3 Gum 418000110

Y4 Seal Pad 719200770

Y5 Seal Pad 719200750

Y8 Flat Washer, M6 716200030

Y9 Spring Washer, M6 716200020

YA Nut, M6 714800620

YB Heat Isolation Wrap 719201080

YC Cushion 417400450

YD Charcoal Filter 745200190

YF C-Clamp 715420010

No. Description Part No. No. Description Part No.

PARTS LIST

10 3

WARNING: THIS MACHINE MUST BE EARTHED.

This product is provided with a standard 13 amp, 230 volt (50Hz). BS 1363 plug, for connection to a standard, domestic electrical supply. Should the plug need changing at any time, ensure that a plug of identical specification is used.

IMPORTANT: The wires in the mains lead should be wired up in accordance with the following colour code:

Green & Yellow - Earth

Blue - Neutral

Brown - Live

As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:

Connect the GREEN & YELLOW cord to terminal marked with a letter E or Earth symbol

Connect BROWN cord to plug terminal marked letter L

Connect BLUE cord to plug terminal marked letter N

We recommend that this machine is connected to the mains supply through a Residual Current Device (RCD).

FUSE RATING The fuse in the plug for this appliance must be rated at 13 amps

ELECTRICAL CONNECTIONS

Thank you for purchasing this CLARKE Dehumidifier which is designed for INDOOR USE ONLY.

Before operating your Dehumidifier, please read this instruction manual thoroughly and carefully follow all instructions. By doing so you will ensure the safety of yourself and that of others around you, and you also can look forward to it giving you long and satisfactory service.

GUARANTEE This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt as proof of purchase.

This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended.

Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission.

This guarantee does not effect your statutory rights.

Waste electrical products should not be disposed of with household waste. Please dispose of at your local recycling facility.

SAFETY PRECAUTIONS

WARNING This appliance is for domestic use only. Any other use is not recommended and may cause fire, electrical shocks or other injury to person or property.

1. This unit should always be kept in an upright position to avoid any damage to the cooling system. Locate the unit on a flat stable surface.

2. Operate this unit in an ambient temperature between 5OC and 35OC.

3. Ensure that the air inlets and outlets are not blocked or covered. Do not place the unit too close to curtains or other objects (minimum distance: 0.5M).

4. When using the unit to speed up the drying of wet clothes in the room, please keep the clothing at a safe distance from the unit to prevent water from dropping onto the unit.

5. Never place anything on top of the unit and do not cover with any kind of material while in use.

6. This product is intended for domestic and light office use ONLY and not for commercial, industrial or outside use.

7. To protect against electrical shocks, do not immerse unit, plug or cord in water, or spray with liquids.

8. Do not operate the unit with a damaged cord or plug, after it malfunctions or has been dropped or damaged in any way. Return to your local dealer, or CLARKE International for examination and repair.

9. Never unplug the unit without switching off first, as this could damage the electronic circuits in the unit.

10. Always empty the water tank before storing the unit away.

11. Always unplug the unit when not in use or moving location. To disconnect from the power supply, grip the plug and pull from the power socket. Never pull by the cord.

12. Close supervision is necessary when any appliance is used by or near children and pets.

13. Do not run power cord under carpeting, or cover with rugs or runners. Arrange the cord away from areas where it may be tripped over

14. Never operate or store the unit in direct sunlight.

15. To repair the unit take it to a qualified service engineer. Repairs carried out by unqualified people may cause damage to the unit or injury to persons or property and void the warranty.

16. Where possible avoid the use of an extension cable as they may overheat and cause a risk of fire. Only use an extension cord after ensuring it is in perfect condition.

17. Do not use the unit without the AIR FILTER.

18. Check the household voltage to ensure it matches the units rated specification before operating.

PARTS LIST AND DRAWING

4 9

The Control Panel

Humidistat Turn anticlockwise to OFF to switch off the unit.

Turn clockwise to CONT for continuous dehumidification.

Between OFF and CONT, your Dehumidifier automatically turns on and off according to the position of the dial to regulate the humidity (generally, about 70% relative humidity for WET, 60% RH for MID and 50% RH for DRY).

Indicators FULL indicator illuminates when the bucket is full of water or incorrectly installed.

Switch off and unplug the unit. Empty the water tank and install the bucket.

2. DEHUMIDIFY indicator illuminates to indicate the unit is running in the normal dehumidification mode.

3. DEFROST Indicator blinks when the unit is defrosting. It will auto-return to dehumidification once the defrost cycle is complete.

FEATURES & OPERATING INSTRUCTIONSTROUBLESHOOTING Please Note:

The humidity display will differ from the real value for a while when first operating the unit, while pausing when the bucket is full, or while the fan has stopped.

The compressor is controlled to stay off at least 3 minutes after it stops, and then plugged in again to ensure a smooth start. This will also extend the life of the unit.

If your Dehumidifier stops working please check the following items first

When unit fails to run:

Is power cord unplugged or the power off?

Is the humidistat set properly?

Is FULL lit? Is the bucket in the correct position? Check and refit the bucket.

When the performance seems poor:

Are there any doors or windows open?

Is steam being generated in the room?

Is the room too big?

Is the filter dirty? Clean it. Refer to the filter cleaning instructions.

Is the inlet or the outlet covered?

Is the room temperature or humidity low?

When noise occurs:

Is the unit on a flat level surface. Move the dehumidifier.

Is the air filter dirty? Clean the filter.

This model operates within the ambient temperatures of 5OC to 35OC.

Do not operate the unit below 5OC. This could cause an accumulation of ice in the unit.

If icing occurs, unplug the unit and move to a place where water can be drained away.

Whenever the compressor stops there will be at least a 3 minute wait before it will restart, so as to ensure a smooth start. This will also extend the life of the unit.

SPECIFICATIONS Model: ...........................................................CD1150

Operating Temperature Range: ................5OC - 35OC

Moisture removal: ........................................10 Litres/day (30OC RH80%)

Water tank capacity: ..................................3.5 Litres

Power: ...........................................................253W

Voltage: ........................................................230V 50Hz

Net Weight: ..................................................13kg

58

Emptying the Bucket 1. When the bucket is full the FULL light blinks.

2. Do not remove the bucket immediately, as the machine is still working. Wait a few minutes, as the dehumidifier is about to stop operating.

3. To remove the bucket, pull it out by gripping each side of the unit, and lift carefully. After pouring the water away, clean the bucket and restore to the correct position.

HOW TO USE EFFECTIVELY

To Drain Water You may use a hose with an inner diameter of 12.7mm (1/2 inch) for continuous drainage:

1. Use a screwdriver to remove the knock-out at the back. Attach the hose to the connector through the hole.

2. The hose should lead to the drain with no sharp bends.

To operate safely Do not insert small objects into the unit or this will damage it and cause a hazard.

Place the unit in an upright position on a stable, flat surface or the unit could leak.

Fitting the filter If you use a carbon filter, pull out the filter frame from the back of the machine. Unpack the carbon filter, fit into the frame and refit.

Cleaning the filter If the filter(s) is clogged with dust, the airflow and the performance of the unit will be affected and the unit will become noisy. It is recommended to check and clean the air filter every 2 weeks.

1. Turn off the machine and pull out the filter at the back.

2. Vacuum the nylon filter or wash it with clean water and dry it thoroughly.

IMPORTANT: ENSURE THAT IT IS COMPLETELY DRY BEFORE REFITTING IT TO YOUR DEHUMIDIFIER. NEVER OPERATE YOUR DEHUMIDIFIER WITHOUT THE NYLON FILTER FITTED.

3. If you have fitted the activated carbon filter, replace after using it for 3 or 6 months, when the filter side has changed from white to a dark colour.

MAINTENANCE

Relocating the unit 1. Castors are provided to allow you to move the unit with ease.

2. Turn off the unit and unplug from the power supply.

3. Empty the water bucket to avoid spillage.

4. Move the unit and relocate. Before switching on, ensure that the dehumidifier is stable and the bucket is correctly installed.

4. Never leave a dirty carbon filter in the unit or malfunction may occur. Contact your local dealer or CLARKE International Parts Department for a replacement.

5. Clean the air inlet and outlet with a soft cloth or vacuum with a hose attac

Manualsnet FAQs

If you want to find out how the 6470617 Clarke works, you can view and download the Clarke 6470617 CD1150 Dehumidifier Instructions on the Manualsnet website.

Yes, we have the Operating and Maintenance Instructions for Clarke 6470617 as well as other Clarke manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Operating and Maintenance Instructions should include all the details that are needed to use a Clarke 6470617. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Clarke 6470617 CD1150 Dehumidifier Instructions is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Clarke 6470617 CD1150 Dehumidifier Instructions consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Clarke 6470617 CD1150 Dehumidifier Instructions free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Clarke 6470617 CD1150 Dehumidifier Instructions, simply download the document to your computer. Once downloaded, open the PDF file and print the Clarke 6470617 CD1150 Dehumidifier Instructions as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.