NOTE: Our products are designed, tested and built in accordance with DOE standardized procedures; however, actual operating results and efficiencies may vary based on manufacturing and supplier tolerances, equipment configuration, operating conditions and installation practices.

NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

USER: PLEASE READ ALL INSTRUCTIONS IN THE MANUAL AND RETAIN ALL MANUALS FOR FUTURE REFERENCE.

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in personal injury, death, or property damage.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Leave the building immediately. Immediately call your gas supplier from a neighbors phone. Follow the gas suppliers instructions. If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

! WARNING

ELECTRICAL OPERATION HAZARD

Failure to follow this warning could result in personal injury, death, or property damage.

Do not use this furnace if any part has been under water. A flooddamaged furnace is extremely dangerous. Attempts to use the furnace can result in fire or explosion. A qualified service agency should be contacted to inspect the furnace and to replace all gas controls, control system parts, and electrical parts that have been wet, or the entire furnace if deemed necessary.

! WARNING

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in personal injury and/or death.

Carbon Monoxide is invisible, odorless, and toxic! Install a carbon monoxide alarm in your home, even if you do not own a gas appliance. Locate the carbon monoxide alarm in the living area of your home and away from gas appliances and doorways to attached garages. Follow the alarm manufacturers instruction included with the alarm.

! WARNING

A11263

2

TABLE OF CONTENTS

WELCOME TO A NEW GENERATION OF COMFORT 2. . . .

FURNACE COMPONENTS 3. . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS 4. . . . . . . . . . . . . . . . . . . . . . . . .

BEFORE STARTING YOUR FURNACE 5. . . . . . . . . . . . . . . . .

STARTING YOUR FURNACE 5. . . . . . . . . . . . . . . . . . . . . . . . .

SHUTTING DOWN YOUR FURNACE 8. . . . . . . . . . . . . . . . . .

PERFORMING ROUTINE MAINTENANCE 8. . . . . . . . . . . . .

FILTERING OUT TROUBLE 9. . . . . . . . . . . . . . . . . . . . . . . . . .

COMBUSTION AREA AND VENT SYSTEM 11. . . . . . . . . . .

WINTERIZATION 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

A CHECKUP CHECKLIST 13. . . . . . . . . . . . . . . . . . . . . . . . . .

BEFORE YOU REQUEST A SERVICE CALL 13. . . . . . . . . . .

INSTALLATION DATA 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

WELCOME TO TODAYS GENERATION OF COMFORT

Congratulations! In light of rising energy costs, a 90+% AFUE Condensing Gas Furnace from Carrier Corporation is among the soundest investments todays homeowner can make. Your new furnace is truly a triumph of technology in home heating. A revolutionary design employs two heat exchangers to squeeze out the maximum amount of heat from the fuel consumed. In fact, your new furnace is so efficient, over 90%* of

the heat generated during combustion is captured and delivered inside your home. This furnace is among the safest, most dependable, energyefficient furnaces you can buy today. We are proud of the technological advances incorporated into the design of this furnace. With only minimal care, your new furnace will deliver many years of moneysaving home comfort and enjoyment. Spend just a few minutes with this manual to learn the operation of your new furnace and the small amount of maintenance it takes to help keep it operating at peak efficiency year after year. * The output capacity and any representations of efficiency for this furnace are based on standard U.S. Department of Energy test procedures.

CERTIFIED

Use of the AHRI Certified TM Mark indicates a manufacturers participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in dangerous operation, serious injury, death, or property damage.

Improper servicing could result in dangerous operation, serious injury, death or property damage.

Before servicing, disconnect all electrical power to furnace.

When servicing controls, label all wires prior to discon- necting. Reconnect wires correctly.

Verify proper operation after servicing.

! WARNING

3

FURNACE COMPONENTS Furnace shown in upflow position; may be used in downflow or horizontal orientation or applications.

RATING PLATE NOT SHOWN (LOCATED ON BLOWER DOOR)

GAS VALVE MAIN LIMIT SWITCH (BEHIND GAS VALVE)

REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY IN APPEARANCE.

ELECTRICAL JUNCTION BOX (IF REQUIRED, LOCATION MAY VARY)

MEDIA CABINET

OPERATING INSTRUCTIONS NOT SHOWN (LOCATED ON MAIN FURNACE DOOR, SEE OPERATING INSTRUCTIONS INSIDE DOOR FIGURE).

FURNACE CONTROL BOARD

MANUAL RESET ROLLOUT SWITCH

FLAME SENSOR

MANUAL RESET ROLLOUT SWITCH

GAS BURNER

HOT SURFACE IGNITER

INDUCER MOTOR ASSEMBLY

BLOWER AND MOTOR

CAPACITOR/ POWER CHOKE (IF USED)

BLOWER DOOR SAFETY SWITCH

A170154

Fig. 1 Furnace Components

4

SAFETY CONSIDERATIONS Installing and servicing of heating equipment can be hazardous due to gas and electrical components. Only trained and qualified personnel should install, repair, or service heating equipment.

Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed by trained service personnel. Observe safety precautions in this manual, on tags, and on labels attached to the furnace and other safety precautions that may apply.

Recognize safety information. This is the safetyalert symbol . When you see this symbol on the furnace and in instructions or manuals, be alert to the potential for personal injury.

Understand the signal words DANGER, WARNING, CAUTION, and NOTE. DANGER, WARNING, and CAUTION are used with the safetyalert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation. To minimize the possibility of serious personal injury, fire, damage to your furnace, or improper operation, carefully follow these safety rules which apply to both directvent and nondirect vent applications: Your new gas furnace may have been installed in one of two

ways, as a directvent (2pipeFig. 2) application or as a

nondirect vent (1pipeFig. 3) application.

In a directvent (2pipe) application, your furnace uses air from outside the home for combustion and vents flue gas to the outdoors. This type of application will have two pipes running from the furnace to the outdoors. In some cases, the inlet air pipe may be located in an area that has access to outdoor air, such as an attic. In all cases, the outlet vent pipe must be routed to the outdoors. (See Fig. 2.) In this application, the vent and airintake pipes must terminate outside the structure and must not be obstructed in any way. Do not block or obstruct air openings on furnace or spaces around furnace.

In a nondirect vent (1pipe) application, your furnace uses air from adjacent to the furnace for combustion and vents flue gas to the outdoors. This type of application will have only one pipe running from the furnace to the outdoors. (See Fig. 3.) The other pipe will terminate in the same space as the furnace and is the source of combustion air for your furnace. Therefore, the furnace must not be enclosed in an airtight room or be sealed behind solid doors. It must have adequate airflow for efficient combustion and safe ventilation. Do not obstruct the combustionair pipe in any way. The vent pipe must terminate outside the structure and must not be obstructed in any way. Do not block or obstruct air openings or space around furnace.

FIRE OR EXPLOSION HAZARD

Failure to follow warnings could result in personal injury, death, or property damage.

Keep insulation clear of furnace and maintain clearances shown on unit clearance label.

Do not keep combustible materials, gasoline, and other flammable liquids or vapors around your furnace.

! WARNING

CARBON MONOXIDE POISONING HAZARD

Failure to follow instructions could result in severe personal injury or death due to carbon monoxide poisoning, if combustion products infiltrate into the building.

Check that all openings in the outside wall around the vent (and air intake) pipe(s) are sealed to prevent infiltration of combustion products into the building.

Check that furnace vent (and air intake) terminal(s) are not obstructed in any way during all seasons.

! WARNING

A11254

Fig. 2 Exterior Vent Pipes

A11255

Fig. 3 Interior Combustion Air Pipe

5

FIRE OR EXPLOSION HAZARD

Failure to follow this warning could result in personal injury, death, or property damage.

Do not keep combustible materials, gasoline, and other flammable liquids or vapors around your furnace.

! WARNING

Keep the area around your furnace clear and free of combustible

materials, gasoline, and other flammable liquids and vapors.

A92182

Fig. 4 NO combustible materials near furnace

Do not cover the furnace, store trash or debris near it, or in any

way block the ow of fresh air to the unit.

UNIT OPERATION HAZARD

Failure to follow this caution may result in intermittent unit operation.

For proper and safe operation the furnace needs air for combustion and ventilation. Do not block or obstruct air openings on the furnace, air opening to the area in which the furnace is installed, and the space around the furnace.

CAUTION!

In addition to the safety rules above, make sure that the following combustionair requirements are met for nondirect vent applications:

Combustion air must be clean and uncontaminated with chlorine

or fluorine. These compounds are present in many products

around the home, such as: water softener salts, laundry bleaches,

detergents, adhesives, paints, varnishes, paint strippers, waxes,

and plastics.

Make sure the combustion air for your furnace does not contain

any of these compounds. During remodeling be sure the

combustion air is fresh and uncontaminated. If these compounds

are burned in your furnace, the heat exchangers may deteriorate.

A furnace installed in an attic or other insulated space must be

kept free and clear of insulating material. Examine the furnace

area when the furnace is installed or when insulation is added.

Some insulation materials may be combustible.

Should the gas supply fail to shut off or if overheating occurs,

shut off the gas valve to the furnace before shutting off electrical

supply.

This furnace contains SAFETY DEVICES which must be MANUALLY RESET. If the furnace is left unattended for an extended period of time, have it checked periodically for proper operation. This precaution will prevent problems associated with no heat, such as frozen water pipes, etc. See Before You Request a Service Call section in this manual.

BEFORE STARTING YOUR FURNACE Examine the furnace installation to determine that:

1. All flue gas carrying areas external to the furnace (i.e. chim- ney, vent connector) are clear and free of obstructions.

2. The vent connector is in place, slopes upward and is physic- ally sound without holes or gaps.

3. The returnair duct connection(s) is physically sound, is sealed to the furnace casing, and terminates outside the space containing the furnace.

4. The physical support of the furnace is sound without sag- ging cracks, gaps, etc. around the base.

5. There are no obvious signs of deterioration of the furnace. 6. The burner flames are in good adjustment, See Fig. 5 (by

comparison with pictorial sketches or drawings of the main burner flame).

Burner Flame

Burner

Manifold A11461

Fig. 5 Burner Flame Adjustment

STARTING YOUR FURNACE

FIRE AND EXPLOSION HAZARD

Failure to follow this warning could result in personal injury, death or property damage.

Should the gas supply fail to shut off or if overheating occurs, turn off the manual gas valve to the furnace BEFORE turning off the electrical supply and install lockout tag.

! WARNING

Instead of a continuously burning pilot flame which wastes valuable energy, your furnace uses an automatic, hot surface ignition system to light the burners each time the thermostat signals the furnace to start.

Follow these important safeguards: Never attempt to manually light the burners with a match

or other source of flame.

6

A92319

Fig. 6 Do Not Light Burner with Match

Read and follow the operating instructions on inside of main furnace door, especially the item that reads as fol- lows: (See Fig. 31.) Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low B in the safety information on furnace label. If you dont smell gas, go to the next step.

If a suspected malfunction occurs with your gas control system, such as the burners do not light when they should, refer to the shutdown procedures on inside of main furnace door, or in the Shutting Down Your Fur- nace section and call your dealer as soon as possible.

CHECK AIR FILTER: Before attempting to start your furnace, be sure the furnace filter is clean and in place. See Performing Routine Maintenance section in this manual. Do not run the furnace without a filter in place. Then proceed as follows:

STEPS FOR STARTING YOUR FURNACE

1. Set your room thermostat to the lowest temperature setting and set the MODE to OFF.. See Fig. 7.

A09564

Fig. 7 Lowest Temperature Setting

2. Close the external manual gas valve. See Fig. 8.

CLOSE

A06188

Fig. 8 Close Valve

3. Turn OFF electrical supply to the furnace. See Fig. 9.

A92185

Fig. 9 Turn Off Electrical Supply

4. Remove the main furnace door. See Fig. 10.

A11256

Fig. 10 Remove Main Furnace Door (Upflow Configuration)

7

5. Turn the control switch on the gas control to the OFF position and wait five minutes. See Fig. 11. Then smell for gas, includ- ing near the floor. If you smell gas, STOP! Follow B on fur- nace label. If you dont smell gas, go to next step.

NAT. GAS

CONSULT MANUAL BEFORE

ADJUSTING GAS

PRESSURE

O FF O N

GAS CONTROL SWITCH SHOWN IN OFF POSITION

GAS CONTROL SWITCH SHOWN IN OFF POSITION

TWO-STAGE GAS CONTROLSINGLE-STAGE GAS CONTROL

MODULATING GAS CONTROL

A11292

Fig. 11 Control Switch to OFF

6. After waiting five minutes, turn control switch on the gas con- trol to the ON position. Turn the control switch to ON. See Fig. 12.

NAT. GAS

CONSULT MANUAL BEFORE

ADJUSTING GAS

PRESSURE

O FF O N

GAS CONTROL SWITCH SHOWN IN ON POSITION

TWO-STAGE GAS CONTROLSINGLE-STAGE GAS CONTROL

GAS CONTROL SWITCH SHOWN IN ON POSITION

MODULATING GAS CONTROL

A11291

Fig. 12 Control Switch to ON

7. Replace main furnace door. See Fig. 13.

A11257

Fig. 13 Furnace Door Replaced (Upflow Configuration)

8. Turn ON the electrical supply to the furnace and wait one minute. See Fig. 14.

A92359

Fig. 14 Turn on Electrical Supply

9. Open the external manual gas valve. See Fig. 15.

OPEN

A06189

Fig. 15 Open Valve

10. Set the room thermostat MODE to HEAT and adjust the set point to a temperature slightly above the room temperature. This will automatically signal the furnace to start.

11. When the furnace receives the start signal, the combustion air draft inducer is started. When the pressure switch senses that there is sufficient combustion air, the hot surface igniter is en- ergized. After the hot surface igniter is heated for about 20 seconds, the gas valve permits gas to flow to the main burners. After igni- tion and a time delay of up to 60 seconds, the furnace blower will start. Variablecapacity furnaces start at low speed until the control makes the necessary adjustments to operate the blower at either the low or highheat speed.

NOTE: If the main burners fail to ignite after four attempts, the furnace control system will lock out. If lockout occurs, main burners fail to light, or blower does not come on, shut down the furnace and call your dealer for service.

12. Set your thermostat to the temperature that satisfies your comfort requirements. SUGGESTION: Setting the thermo- stat back a few degreesand compensating for the differ- ence with warmer clothingcan make a big difference in your fuel consumption on extremely cold days. The few de- grees at the top of your thermostat comfort level are the most costly degrees to obtain.

When the room temperature drops below the temperature selected on the thermostat, the furnace will switch on automatically. When the room temperature reaches the setting selected on the thermostat, the furnace will be automatically switched off. Continuous Fan Operation Some thermostats have a FAN switch with two selections: AUTO and ON. When the thermostat is set on AUTO, the furnace blower cycles on and off, controlled by the thermostat. In ON position, the furnace blower runs continuously. Continuous fan keeps the temperature level in your home more evenly balanced. It also continuously filters the indoor air.

On all but the base series furnace, the blower speed can be increased or decreased if desired due to change of seasons, large

8

gatherings in your home, etc. Simply change your FAN from ON to OFF for 1 to 3 seconds (or AUTO depending on your thermostat), and then return to ON. The blower will switch to the next higher speed. There are at least three speeds to choose from. If the blower is running on its highest speed, a request to change will direct the blower to return to its lowest speed.

SHUTTING DOWN YOUR FURNACE Should you need to shut down your furnace for service or maintenance, you will need to turn the furnace off. The following procedures must be followed:

1. Set your room thermostat to the lowest temperature setting and set the MODE to OFF. See Fig. 16.

A09564

Fig. 16 Lowest Temperature Setting

2. Close the external manual gas valve. See Fig. 17.

CLOSE

A06188

Fig. 17 Close the External Manual Valve

3. Turn off electrical supply to the furnace. See Fig. 18.

A92185

Fig. 18 Turn Off Electrical Supply

4. Remove main furnace door. See Fig. 10.

5. Turn control switch on the gas control to OFF position. See Fig. 11.

6. Replace main furnace door. See Fig. 13.

7. If the furnace is being shut down because of a malfunction, call your dealer as soon as possible.

UNIT AND PROPERTY DAMAGE HAZARD

Failure to follow this caution may result in unit component or property damage.

Furnace is not to be installed, operated, and then turned off and left turned off in an unoccupied structure during winter. See Winterization procedures in this manual.

CAUTION!

MINIMUM & MAXIMUM TEMPERATURE SETTING FOR YOUR FURNACE

This furnace is designed for minimum continuous returnair temperature of 60F (16C) or intermittent operation down to 55F (13C) such as when used with a night setback thermostat. Returnair temperature must not exceed 80F (27C). Failure to follow these returnair temperature limits may affect reliability of heat exchangers, motors, and controls.

PERFORMING ROUTINE MAINTENANCE NOTE: The qualified installer or agency must use only factoryauthorized replacement parts, kits, and accessories when modifying this product.

Installing and servicing of heating equipment can be hazardous due to gas and electrical components.

Only trained and qualified personnel should install, repair, or service heating equipment. Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed by trained service personnel. Observe safety precautions in this manual, on tags, and on labels attached to the furnace and other safety precautions that may apply.

With proper maintenance and care, your furnace will operate economically and dependably. Instructions for basic maintenance are found on this and the following pages. However, before beginning maintenance, follow these safety precautions:

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

Turn off electrical power supply to your furnace and install lockout tag before removing the access doors to service or perform maintenance.

! WARNING

CUT HAZARD

Failure to follow this caution may result in personal injury.

Although special care has been taken to minimize sharp edges, be extremely careful when handling parts or reaching into the furnace. Wear safety glasses, gloves, and appropriate protective clothing.

CAUTION!

9

FILTERING OUT TROUBLE NOTE: The manufacturer has specified filters which will enable your furnace to provide lasting comfort and efficiency throughout its life. Contact your dealer to help you choose filters for your furnace that both collect dirt before it enters your furnace, as well as provide a low resistance to circulating air. Avoid filters that report high cleaning efficiencies, but do not allow air to pass easily through them.

UNIT PERFORMANCE HAZARD

Failure to follow this caution may result in unit component damage.

Never operate your furnace without a filter in place. Doing so may damage the furnace blower motor. An accumulation of dust and lint on internal parts of your furnace can cause a loss of efficiency.

CAUTION!

PERSONAL INJURY HAZARD

Failure to follow this caution may result in personal injury.

Use care when cutting support rods in filters to protect against flying pieces and sharp rod ends. Wear safety glasses, gloves, and appropriate protective clothing.

CAUTION!

A dirty filter will cause excessive stress on the furnace, heat exchanger, and blower motor, and can cause it to overheat and automatically shut down. The furnace filter should be checked every four weeks and be cleaned or replaced if necessary. If installed with factoryspecified disposable media filter, check or replace filter before each heating and cooling season. Replace disposable media filter at least once a year.

If your furnace filter needs replacing, be sure to use the same size and type of filter that was originally specified. The air filter for the furnace may be located an external filter cabinet attached to the side or bottom of the furnace casing. If the air filter has been installed in another location, contact your dealer for instructions. To inspect, clean and/or replace the air filter(s), follow these steps:

1. Turn off electrical supply to the furnace. See Fig. 19.

2. Remove air filter from the filter cabinet.

a. Remove filter cabinet door. (See Fig. 20 and 21.) NOTE: It maybe necessary to remove one thumbscrew.

b. Slide air filter out of furnace. Keep dirty side up (if dirty) to avoid spilling dirt. See Fig. 22 and 23.

3. Inspect the filter. If torn replace it.

NOTE: If a washable filter was suppliedwith the furnace and has been replaced by:

Disposable media filterDo not clean. If dirty, replace only with media filter having the same part number and size. Install with airflow direction arrow pointing to- wards blower.

Electronic Air Cleaner (EAC), refer to the EAC Owners Manual for maintenance information.

4. If washable filter, wash filter (if dirty) in a sink, bathtub, or outside with a garden hose. Always use cold tap water. A mild liquid detergent may be used if necessary. Spray water

through filter in the opposite direction of airflow. Allow fil- ter to dry.

5. Reinstall clean air filter.

6. Turn on electrical supply to the furnace.

If your furnace air filter needs to be replaced, be sure to use a factoryauthorized filter of the same size that was originally specified. Use the filter tables and compare your furnace size with the proper filter size.

A92185

Fig. 19 Turn Off Electrical Supply

A00225

Fig. 20 Removal of Filter Cabinet Door from Side Blower Cabinet

A00226

Fig. 21 Removal of Filter Cabinet Door from Bottom Blower Cabinet

10

A00227

Fig. 22 Removal of Filter from Side Blower Cabinet

A00228

Fig. 23 Removal of Filter from Bottom Blower Cabinet

A00229

Fig. 24 Replacement of Filter Cabinet Door to Side Blower Cabinet

A00230

Fig. 25 Replacement of Filter Cabinet Door to Bottom Blower Cabinet

Table 1 Air Filter Located in Filter Cabinet FILTER CABINET HEIGHT - IN (MM) FILTER SIZE - IN (MM) FILTER TYPE

16 (406)

(1) 16 x 25 x 3/4* (406 x 635 x 19) or

(1) 16 x 25 x 4-5/16 (406 x 635 x 110)

Washable

20 (508)

(1) 20 x 25 x 3/4* (508 x 635 x 19) or

(1) 20 x 25 x 4-5/16 (508 x 635 x 110)

Washable

24 (610)

(1) 24 x 25 x 3/4*or (610 x 635 x 19) or

(1) 24 x 25 x 4-5/16 (610 x 635 x 110)

Washable

* Filters with a side returnair may have a different filter size. Measure the filter to obtain the correct size. Recommended to maintain air filter face velocity. See Product Data for part number.

11

COMBUSTION AIR AND VENT SYSTEM

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in personal injury or death.

If holes are found or if the vent pipe is obstructed or is not connected, toxic fumes can escape into your home. DO NOT OPERATE YOUR FURNACE. Call your dealer for service.

! WARNING

UNIT OPERATION HAZARD

Failure to follow this caution may result in intermittent unit operation.

For proper and safe operation the furnace needs air for combustion and ventilation. Do not block or obstruct air openings on the furnace, air opening to the area in which the furnace is installed, and the space around the furnace.

CAUTION!

Visually inspect the combustion area and vent system before each heating season. Make sure that all PVC pipes leading into the combustion area and vent are free from any cracks and sags. An accumulation of dirt, soot, or rust can mean a loss of efficiency and improper performance. Buildups on the main burners can cause faulty firing. This delayed ignition is characterized by an alarmingly loud sound.

Check the combustionair intake adjacent to the furnace or outside your home for blockage. Also check the vent pipe on the outside of your home for blockage. NOTE: If your furnace makes a loud noise when the main burners are ignited, shut down the furnace and call your servicing dealer.

Use your flashlight and follow these steps for inspecting the combustion area and vent system of your furnace:

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in personal injury or death.

If dirt, rust, soot, or scale accumulations are found, call your dealer. Do not operate your furnace.

! WARNING

1. Turn off electrical supply and gas supply to the furnace and remove the main furnace door. See Fig. 7 8 9 10 and 11.

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

Turn off electrical power supply to your furnace and install lockout tag before removing the access doors to service or perform maintenance.

! WARNING

2. Inspect the gas burners, igniter area, and remainder of fur- nace for dirt, rust, soot or scale.

GAS BURNER

HOT SURFACE IGNITOR

GAS VALVE

MAIN LIMIT SWITCH (BEHIND GAS VALVE)

FLAME SENSOR

MANUAL RESET LIMIT SWITCH

MANUAL RESET LIMIT SWITCH

ASSEMBLY

A11319

Fig. 26 Gas Burner Assembly (Upflow)

GAS BURNER

HOT SURFACE IGNITOR

GAS VALVE

MAIN LIMIT SWITCH (BEHIND GAS VALVE)

FLAME SENSOR

MANUAL RESET LIMIT SWITCH

MANUAL RESET LIMIT SWITCH

ASSEMBLY

A11320

Fig. 27 Gas Burner Assembly (Downflow)

3. Inspect the combustionair and vent PVC pipes for sags, holes, cracks, water leaks, blockage or disconnections. Hori- zontal portions of vent pipe must slope downward toward the furnace.

4. If your furnace is free of the above conditions,turn on elec- trical and gas supplies to the furnace.

5. Start your furnace and observe its operation. Watch the burner flames to see if they are clear blue, almost transpar- ent.. See Fig. 28. If you observe a suspected malfunction, or the burner flames are not clear blue, call your dealer.

6. Replace main furnace door.

Burner Flame

Burner

Manifold A11461

Fig. 28 Burner Flame Adjustment

12

WINTERIZATION

UNIT AND PROPERTY DAMAGE HAZARD

Failure to follow this caution may result in unit component or property damage.

If the furnace is installed in an unconditioned space where the ambient temperatures may be 32 F (0 C) or lower, freeze protection measures must be taken to prevent minor property or product damage.

CAUTION!

Since the furnace uses a condensing heat exchanger, some water will accumulate in the unit as a result of the heat transfer process. Therefore, once it has been operated, it cannot be turned off and left off for an extended period of time when temperatures will reach 32F (0C) or lower unless winterized. Follow these procedures to winterize your furnace:

UNIT COMPONENT DAMAGE HAZARD

Failure to follow this caution may result in damage to the furnace and other property damage.

Do not use ethylene glycol (Automotive antifreeze coolant or equivalent). Failure of plastic components may occur.

CAUTION!

1. Obtain propylene glycol (RV/swimming pool antifreeze or equivalent).

2. Turn off gas and electrical supplies to your furnace.

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

Turn off electrical power supply to your furnace and install lockout tag before removing the access doors to service or perform maintenance.

! WARNING

3. Remove furnace control compartment door. 4. Remove one of the unused rubber plugs in the port on the

collector box opposite the condensate trap. See Fig 30. 5. Connect a field supplied 3/8-in. (9.5-mm) ID tube to the

open port on the collector box 6. Insert a field supplied funnel into the tube.

7. Pour 1 quart of anti-freeze solution into the funnel/tube. Antifreeze should run through the inducer housing, overfill condensate trap and flow to an open drain.

8. If a condensate pump is used, check with pump manufacturer to verify pump is safe for use with antifreeze used. Allow pump to start and pump anti-freeze to open drain.

9. Remove funnel and tube from collector box.

10. Replace plug in collector box.

11. Remove the other plug and repeat steps 410. 12. Replace main door.

13. When furnace is re-started, flush condensate pump with clear water to check for proper operation before re-starting furnace.

14. Propylene glycol need not be removed before re-starting furnace.

A11392

Fig. 29 Winterizing Furnace

13

A CHECKUP CHECKLIST Your furnace represents an important investment in your familys comfort and your homes value. To keep it performing properly and to prevent future problems, have a trained service specialist give your furnace a professional checkup annually. The following checklist can be used as a guideline to proper service: Inspect all flue gas passages, burners, heat exchangers, coupling

box(es), and inducer assembly.

Inspect all combustionair and vent piping inside structure and

pipe terminations outside the structure.

Check gas pipes leading to and inside of your furnace for leaks.

Inspect and clean the blower motor and wheel.

NOTE: The inducer and blower motors are prelubricated and require no additional lubrication. These motors can be identified by the absence of oil ports on each end of the motor. Inspect and change or clean air filter(s) if necessary.

Inspect all supply and returnair ducts for obstructions, air

leaks, and insulation. Remedy any problem when necessary.

Inspect the returnair duct connection(s) at the furnace to ensure

it is physically sound, sealed to the furnace casing, and

terminates outside the space containing the furnace.

Inspect electrical wiring, connections, and components for loose

connections.

Perform an operational checkout to determine whether your

furnace is working properly and if it requires adjustments.

Inspect all condensate drain tubes and condensate trap assembly

for leaks. The condensate removal system should be cleaned

annually by a qualified service agency. Refer to the Service and

Maintenance Instructions Guide for further information.

Examine the physical support of the furnace. Support should be

sound with no cracks, sagging, gaps, etc. around the base.

Check furnace for any obvious signs of deterioration.

Ask your servicing dealer for further details about an economical

service contract that covers seasonal inspections.

FOR YOUR SAFETY READ BEFORE OPERATING

A11318

Fig. 30 Information Booklet Location

BEFORE YOU REQUEST A SERVICE CALL

If your furnace is not operating or not performing properly, you may save the expense of a service call by checking a few things yourself before calling for service.

NOTE: Record the LED status code BEFORE removing the blower access door or turning off 115v power to the furnace. See the information booklet inside the main furnace door for a service code legend. See Fig. 30.

For insufficient airflow: Check for dirty air filter(s).

Check for blocked returnair or supplyair grilles. Be sure they

are open and unobstructed.

If problem still exists, call your dealer for service.

If furnace fails to operate: Follow this checklist step by step, advancing to the next stop only if furnace fails to start. Check thermostat for proper temperature. Is thermostat set above

room temperature?

Is thermostat set to HEAT mode?

Check fuses and circuit breakers. Is the electrical power supply

switch on?

Is the manual shutoff valve in the gas supply pipe leading to

the furnace open?

NOTE: Turn off electrical supply before continuing with checklist. Is control switch on gas valve in ON position? (Follow startup

procedures if you must reset switch to ON position.)

Check manual reset rollout switch located on the burner box.

See Furnace Components in Fig. 1. If furnace has experienced

high temperature conditions, this switch will shut off the

furnace. Reset it by pushing the button on the switch. If it trips

again, shut down the furnace and call for service. See Shutting

Down Your Furnace section in this manual.

Check for obstructions around the vent termination.

If your furnace still fails to operate, call your service representative. For your convenience, record the furnace product and serial numbers on back page. Should you ever require service, you will have ready access to the information needed by your service representative. This furnace has a light emitting diode (LED) status code display to aid the installer, service technician, or homeowner while installing or servicing the unit. The LED code can be seen through the view port in the blower access panel.

14

NOTE TO EQUIPMENT OWNER:

For your convenience, please record the model and serial numbers of your new equipment in the spaces provided. This information, along with the installation data and dealer contact information will be helpful should your system require maintenance or service.

FURNACE

Model # _____________________________________

Serial # ______________________________________

AIR CONDITIONER OR HEAT PUMP

Model # _____________________________________

Serial # _____________________________________

INDOOR COIL (Furnace Coil or Fan Coil)

Model # _____________________________________

Serial # _____________________________________

INSTALLATION INFORMATION:

Date Installed ________________________________

DEALERSHIP CONTACT INFORMATION:

Company Name_______________________________

Address______________________________________

_____________________________________________

Phone Number _______________________________

Technician Name _____________________________

_____________________________________________

_____________________________________________

Manualsnet FAQs

If you want to find out how the 59SC5 Carrier works, you can view and download the Carrier 59SC5 Owner's Manual on the Manualsnet website.

Yes, we have the Owner's Manual for Carrier 59SC5 as well as other Carrier manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Owner's Manual should include all the details that are needed to use a Carrier 59SC5. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Carrier 59SC5 Owner's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Carrier 59SC5 Owner's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Carrier 59SC5 Owner's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Carrier 59SC5 Owner's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Carrier 59SC5 Owner's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.