Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53090021-01 Printed in U.S.A. Form 09/30/38-14SI Pg 1 10-13 Replaces: 09/30/38-11SI

Installation Instructions Part No: 30RA-900---064, 30RA-900---065, 30RA-900---066, and 38AP-900---005

PACKAGE USAGE

PACKAGE CONTENTS

GENERAL This book contains instructions for the installation of the

wind baffles used on 09DPS018-030, 09DPM035-130, 30RAP010-150, 38APD025-130, and 38APS025-065 units with Motormaster V controls. The Motormaster V control must be purchased separately and is not provided with this kit. Wind baffles must be field installed for all units to ensure prop- er operation at low-ambient temperatures with Motormaster V electronic controller. If the unit is equipped with hail guards, they must be removed before installing the wind baffles.

This kit provides factory designed wind baffles for field in- stallation when running the unit at low ambient air tempera- tures.

The standard outdoor-air temperature limitation of the 30RAP010-015 chillers is 20 F (28.0 C). The standard outdoor-air temperature limitation of the 30RAP018-030 chill- ers is 45 F (7.2 C). The standard outdoor-air temperature limita- tion of the 30RAP035-150 chillers is 32 F (0.0 C).

The standard outdoor-air temperature limitation of the 38APS025-065 condensing units is 45 F (7.2 C). The standard

outdoor-air temperature limitation of the 38APD025-040 and 070-130 condensing units is 32 F (0.0 C). The standard out- door-air temperature limitation of the 38APD050-060 condens- ing units is 25 F (3.9 C).

The standard outdoor-air temperature limitation of the 09DPS and 09DPM units is based on different system factors in- cluding the unit it is paired with, condensing temperature, tem- perature difference, and compressor capacity.

The Motormaster V electronic control low ambient opera- tion kit can be used to extend the system operation down to 20 F (28 C).

SAFETY CONSIDERATIONS

Installation of this accessory can be hazardous due to sys- tem pressures, electrical components and equipment location.

Only trained, qualified installers and service technicians should install, start up, and service this equipment.

When installing this accessory, observe precautions in the literature and on tags, stickers, and labels attached to the equip- ment. Follow all safety codes. Wear safety glasses and work gloves. Use care in handling equipment.

PREINSTALLATION Inspect the contents of the accessory package before install-

ing. File a claim with the shipper if shipping damage is found or contact your Carrier representative if any parts are missing. See Package Contents table for kit package contents.

INSTALLATION

NOTE: Pre-drilled holes may not be provided. Drill pilot holes as necessary using the bracket as a template.

All Units Sizes 010 to 060 To install the accessory wind baffles, perform the following procedure:

1. Install the 3 brackets to the side of the unit using screws provided. See Fig. 1-3 for location.

ACCESSORY PART NUMBER QUANTITY UNITS

30RA-900---064 1 30RAP010,015

30RA-900---065 1

09DPS018,020 30RAP018,020

38APD025 38APS025

2 09DPM035-050 30RAP035,040

30RA-900---066

1

09DPS030 30RAP025,030 38APD027-030 38APS027-030

2

09DPM060 30RAP045-060 38APD040-060 38APS040,050

38AP-900---005 1

09DPM065-130 30RAP070-150

38APS065 38APD070-130

ACCESSORY PART NUMBER

CONTENTS DESCRIPTION QUANTITY

30RA-900---064, 30RA-900---065, 30RA-900---066

Baffle Plate 1 Baffle Plate 1 Bracket 3 Support Bracket 2 Screws 36 or 40

38AP-900---005 Baffle Plate 1 Screw 12

WARNING

Disconnect all power to the unit before performing mainte- nance or service. Electrical shock and personal injury could result.

CAUTION

To avoid damage to refrigerant coils and electronic compo- nents, use extreme care when drilling screw holes and attaching fasteners.

09DPS018-030, 09DPM035-130 30RAP010-150

38APD025-130, 38APS025-065 Wind Baffle Accessory

2

SUPPORT BRACKET BRACKETS

BAFFLE PLATE

SUPPORT BRACKET

Fig. 1 Baffle Location and Assembly 30RAP010,015 Units (Part No. 30RA-900---064)

a30-5634

NOTE: Dimensions are in inches.

BRACKETS

BAFFLE PLATES

SUPPORT BRACKET

SUPPORT BRACKET

BRACKETS BAFFLE PLATES

SUPPORT BRACKET

BAFFLE PLATES

BRACKETS

NOTE: Dimensions are in inches.

Fig. 2 Baffle Location and Assembly 09DPS018-020 Units, 09DPM035-050 Units, 30RAP018,020 Units, 30RAP035,040 Units, 38APD025, and 38APS025 (Part No. 30RA-900---065)

a30-5635

3

2. Install 2 support brackets on the end brackets using screws provided.

3. Install baffle plates on to the brackets installed in Step 1 using the screws provided.

4. For size 035-060 units, repeats Steps 1-4 to install the sec- ond accessory wind baffle on the other side of the unit.

All Units Sizes 065-150 To install the accessory wind baffle, install the baffle plate on the end of the unit oppo- site the control panel, using the screws provided. See Fig. 4 for dimensions. See Fig. 5 for location.

BRACKETS

BAFFLE PLATES

SUPPORT BRACKET

SUPPORT BRACKET

BAFFLE PLATES

BRACKETS

BRACKETS

SUPPORT BRACKET

NOTE: Dimensions are in inches.

Fig. 3 Baffle Location and Assembly 09DPS030 Units; 09DPM060 Units; 30RAP025,030 Units; 30RAP045-060 Units; 38APD027-060 Units; and 38APS027-050 Units (Part No. 30RA-900---066)

a30-5636

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53090021-01 Printed in U.S.A. Form 09/30/38-14SI Pg 4 10-13 Replaces: 09/30/38-11SI

Carrier Corporation 2013

74.00

27.50

TYP 0.50

TYP 1.07

2 SPA @ 12.13 = TYP

24.26

TYP0.62

2.05

TYP 0.62

TYP 0.62

1.00 TYP0.45

14.13

29.69

44.33

59.89

2X R0.156

REF 1.07

71.95

TYP1.28

REF 0.25

TYP3.00 TYP

68.00

9.00

18.00

10X 0.312

8X 45 X CHAMFER OR 0.25 R TO SIUT TOOLING

0.13

SEE DETAIL A

B

B

B

B

DETAIL A

STIFFENING RIB TO SUIT TOOLING

SECTION B-B

NOTE: Dimensions are in inches.

Fig. 4 Baffle Dimensions 09DPM065-130 Units, 38APD070-130 Units, 38APS065 Units, and 30RAP070-150 (Part No. 38AP-900---005)

BAFFLE INSTALLATION L

Manualsnet FAQs

If you want to find out how the 09DPM035-130 Carrier works, you can view and download the Carrier 09DPM035-130 v2 Installation Instructions on the Manualsnet website.

Yes, we have the Installation Instructions for Carrier 09DPM035-130 as well as other Carrier manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Installation Instructions should include all the details that are needed to use a Carrier 09DPM035-130. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Carrier 09DPM035-130 v2 Installation Instructions is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Carrier 09DPM035-130 v2 Installation Instructions consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Carrier 09DPM035-130 v2 Installation Instructions free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Carrier 09DPM035-130 v2 Installation Instructions, simply download the document to your computer. Once downloaded, open the PDF file and print the Carrier 09DPM035-130 v2 Installation Instructions as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.