CS106 Barometric Pressure Sensor

Revision: 7/19 Copyright 1995 2019 Campbell Scientific, Inc.

Limited Warranty The CS106 Barometric Pressure Sensor is warranted for three (3) years subject to this limited warranty:

Products manufactured by CSI are warranted by CSI to be free from defects in materials and workmanship under normal use and service for twelve months from the date of shipment unless otherwise specified in the corresponding product manual. (Product manuals are available for review online at www.campbellsci.com.) Products not manufactured by CSI, but that are resold by CSI, are warranted only to the limits extended by the original manufacturer. Batteries, fine-wire thermocouples, desiccant, and other consumables have no warranty. CSIs obligation under this warranty is limited to repairing or replacing (at CSIs option) defective Products, which shall be the sole and exclusive remedy under this warranty. The Customer assumes all costs of removing, reinstalling, and shipping defective Products to CSI. CSI will return such Products by surface carrier prepaid within the continental United States of America. To all other locations, CSI will return such Products best way CIP (port of entry) per Incoterms 2010. This warranty shall not apply to any Products which have been subjected to modification, misuse, neglect, improper service, accidents of nature, or shipping damage. This warranty is in lieu of all other warranties, expressed or implied. The warranty for installation services performed by CSI such as programming to customer specifications, electrical connections to Products manufactured by CSI, and Product specific training, is part of CSI's product warranty. CSI EXPRESSLY DISCLAIMS AND EXCLUDES ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. CSI hereby disclaims, to the fullest extent allowed by applicable law, any and all warranties and conditions with respect to the Products, whether express, implied or statutory, other than those expressly provided herein.

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing in countries served by Campbell Scientific, Inc. directly. Affiliate companies handle repairs for customers within their territories. Please visit www.campbellsci.com to determine which Campbell Scientific company serves your country.

To obtain a Returned Materials Authorization (RMA) number, contact CAMPBELL SCIENTIFIC, INC., phone (435) 227-9000. Please write the issued RMA number clearly on the outside of the shipping container. Campbell Scientifics shipping address is:

CAMPBELL SCIENTIFIC, INC. RMA#_____ 815 West 1800 North Logan, Utah 84321-1784

For all returns, the customer must fill out a Statement of Product Cleanliness and Decontamination form and comply with the requirements specified in it. The form is available from our website at www.campbellsci.com/repair. A completed form must be either emailed to repair@campbellsci.com or faxed to (435) 227-9106. Campbell Scientific is unable to process any returns until we receive this form. If the form is not received within three days of product receipt or is incomplete, the product will be returned to the customer at the customers expense. Campbell Scientific reserves the right to refuse service on products that were exposed to contaminants that may cause health or safety concerns for our employees.

Safety DANGER MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND TRIPODS, TOWERS, AND ANY ATTACHMENTS TO TRIPODS AND TOWERS SUCH AS SENSORS, CROSSARMS, ENCLOSURES, ANTENNAS, ETC. FAILURE TO PROPERLY AND COMPLETELY ASSEMBLE, INSTALL, OPERATE, USE, AND MAINTAIN TRIPODS, TOWERS, AND ATTACHMENTS, AND FAILURE TO HEED WARNINGS, INCREASES THE RISK OF DEATH, ACCIDENT, SERIOUS INJURY, PROPERTY DAMAGE, AND PRODUCT FAILURE. TAKE ALL REASONABLE PRECAUTIONS TO AVOID THESE HAZARDS. CHECK WITH YOUR ORGANIZATION'S SAFETY COORDINATOR (OR POLICY) FOR PROCEDURES AND REQUIRED PROTECTIVE EQUIPMENT PRIOR TO PERFORMING ANY WORK.

Use tripods, towers, and attachments to tripods and towers only for purposes for which they are designed. Do not exceed design limits. Be familiar and comply with all instructions provided in product manuals. Manuals are available at www.campbellsci.com or by telephoning (435) 227-9000 (USA). You are responsible for conformance with governing codes and regulations, including safety regulations, and the integrity and location of structures or land to which towers, tripods, and any attachments are attached. Installation sites should be evaluated and approved by a qualified engineer. If questions or concerns arise regarding installation, use, or maintenance of tripods, towers, attachments, or electrical connections, consult with a licensed and qualified engineer or electrician.

General Prior to performing site or installation work, obtain required approvals and permits. Comply

with all governing structure-height regulations, such as those of the FAA in the USA. Use only qualified personnel for installation, use, and maintenance of tripods and towers, and

any attachments to tripods and towers. The use of licensed and qualified contractors is highly recommended.

Read all applicable instructions carefully and understand procedures thoroughly before beginning work.

Wear a hardhat and eye protection, and take other appropriate safety precautions while working on or around tripods and towers.

Do not climb tripods or towers at any time, and prohibit climbing by other persons. Take reasonable precautions to secure tripod and tower sites from trespassers.

Use only manufacturer recommended parts, materials, and tools.

Utility and Electrical You can be killed or sustain serious bodily injury if the tripod, tower, or attachments you are

installing, constructing, using, or maintaining, or a tool, stake, or anchor, come in contact with overhead or underground utility lines.

Maintain a distance of at least one-and-one-half times structure height, 20 feet, or the distance required by applicable law, whichever is greater, between overhead utility lines and the structure (tripod, tower, attachments, or tools).

Prior to performing site or installation work, inform all utility companies and have all underground utilities marked.

Comply with all electrical codes. Electrical equipment and related grounding devices should be installed by a licensed and qualified electrician.

Elevated Work and Weather Exercise extreme caution when performing elevated work. Use appropriate equipment and safety practices. During installation and maintenance, keep tower and tripod sites clear of un-trained or non-

essential personnel. Take precautions to prevent elevated tools and objects from dropping. Do not perform any work in inclement weather, including wind, rain, snow, lightning, etc.

Maintenance Periodically (at least yearly) check for wear and damage, including corrosion, stress cracks,

frayed cables, loose cable clamps, cable tightness, etc. and take necessary corrective actions. Periodically (at least yearly) check electrical ground connections.

WHILE EVERY ATTEMPT IS MADE TO EMBODY THE HIGHEST DEGREE OF SAFETY IN ALL CAMPBELL SCIENTIFIC PRODUCTS, THE CUSTOMER ASSUMES ALL RISK FROM ANY INJURY RESULTING FROM IMPROPER INSTALLATION, USE, OR MAINTENANCE OF TRIPODS, TOWERS, OR ATTACHMENTS TO TRIPODS AND TOWERS SUCH AS SENSORS, CROSSARMS, ENCLOSURES, ANTENNAS, ETC.

i

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to specific sections.

1. Introduction................................................................ 1

2. Precautions ................................................................ 1

3. Initial Inspection ........................................................ 1

4. QuickStart .................................................................. 1

5. Overview .................................................................... 3

6. Specifications ............................................................ 4

6.1 Operating Range...................................................................................4 6.2 Accuracy ..............................................................................................4 6.3 General .................................................................................................5

7. Installation ................................................................. 5

7.1 Jumper Settings ....................................................................................5 7.2 Mounting in the Enclosure ...................................................................6 7.3 Wiring ..................................................................................................7

7.3.1 Data Logger Connection ...............................................................7 7.3.2 5-pin Screw Terminal Plug Connector ..........................................9

7.4 Programming ........................................................................................9 7.4.1 CRBasic Instructions................................................................... 10

8. Operations ............................................................... 10

8.1 Multiplier and Offset Calculation....................................................... 10 8.2 Conversion Factors ............................................................................. 11 8.3 Long Cable Lengths ........................................................................... 11 8.4 Output Resolution .............................................................................. 11 8.5 Correcting Pressure to Sea Level ....................................................... 11

9. Maintenance and Calibration .................................. 12

Appendices

A. Importing Short Cut Code Into CRBasic Editor ... A-1

B. Example Programs ................................................ B-1

B.1 CR1000X Program Using Sequential Mode .................................... B-1 B.2 CR1000X Program Using Pipeline Mode ........................................ B-2

Table of Contents

ii

Figures 7-1. CS106 jumper settings .........................................................................6 7-2. ENC100 is a very small enclosure that can house one CS106 .............7 7-3. CS106 wiring diagram .........................................................................8 7-4. Connector key attached to 5-pin screw terminal plug connector .........9 8-1. Point slope graph ................................................................................ 10

Tables 7-1. Wire Color, CS106 Connection, and Data Logger Connection............8 8-1. Conversion Factors for Alternative Pressure Units ............................ 11

CRBasic Examples B-1. CR1000X Program Using Sequential Mode .................................... B-1 B-2. CR1000X Program Using Pipeline Mode ........................................ B-2

1

CS106 Barometric Pressure Sensor 1. Introduction

The CS106 measures barometric pressure for the range of 500 to 1100 mb. This range equates to from below sea level (as in a mine) to over 15,000 feet above sea level. Designed for use in environmental applications, the CS106 is compatible with all Campbell Scientific data loggers.

This manual provides information only for CRBasic data loggers. For retired Edlog data logger support, access a retired manual at www.campbellsci.com/old-manuals.

2. Precautions READ AND UNDERSTAND the Safety section at the front of this

manual.

Warning: Failure to protect the sensor from condensation may result in permanent damage.

Warning: Improper wiring may damage the CS106 beyond repair.

Care should be taken when opening the shipping package to not damage or cut the cable jacket. If damage to the cable is suspected, consult with a Campbell Scientific support and implementation engineer.

Although the CS106 is rugged, it should be handled as a precision scientific instrument.

3. Initial Inspection Upon receipt of the CS106, inspect the packaging and contents for

damage. File damage claims with the shipping company.

4. QuickStart A video that describes data logger programming using Short Cut is available at: www.campbellsci.com/videos/cr1000x-datalogger-getting-started-program- part-3. Short Cut is an easy way to program your data logger to measure the CS106 and assign data logger wiring terminals. Short Cut is available as a download on www.campbellsci.com. It is included in installations of LoggerNet, PC200W, PC400, or RTDAQ.

NOTE

CS106 Barometric Pressure Sensor

2

The following procedure also describes programming with Short Cut.

1. Open Short Cut and click Create New Program.

2. Double-click the data logger model.

3. In the Available Sensors and Devices box, type CS106. You can also locate the sensor in Sensors | Meteorological | Barometric Pressure folder. Double-click CS106 Barometric Pressure Sensor. Type the Sea Level Elevation Correction. The default units for the sea level elevation correction is meters; this can be changed by clicking on the Elevation Correction Units box and selecting Feet. Defaults for the barometric pressure measurement and frequency of the measurement are mbar and Hourly, consecutively. These can be changed by clicking the Barometric Pressure and Measure sensor boxes and selecting different values. Click on the Wiring tab to see how the sensor is to be wired to the data logger.

4. Repeat step three for other sensors.

CS106 Barometric Pressure Sensor

3

5. In Output Setup, type the scan rate, meaningful table names, and the Data Output Storage Interval.

6. Select the measurement and its associated output options.

7. Click Finish and save the program. Send the program to the data logger if the data logger is connected to the computer.

8. If the sensor is connected to the data logger, check the output of the sensor in the data display in LoggerNet, PC400, RTDAQ, or PC200W to make sure it is making reasonable measurements.

Improper wiring may damage the CS106 beyond repair.

5. Overview The CS106 uses the Vaisala Barocap silicon capacitive pressure sensor, which has been designed for accurate and stable measurement of barometric pressure. This barometer is encased in a plastic shell (ABS/PC blend) fitted with an intake valve for pressure equalization.

WARNING

CS106 Barometric Pressure Sensor

4

The CS106 outputs a linear 0 to 2.5 VDC signal that corresponds to 500 to 1100 mb. It can be operated in a shutdown or normal mode (see Section 7.1, Jumper Settings (p. 5)). In the shutdown mode, the data logger switches 12 VDC power to the barometer during the measurement. The data logger then powers down the barometer between measurements to conserve power.

If the CS106 and data logger will be housed in different enclosures, the CABLE5CBL-L should be used instead of the cable that is shipped with the CS106.

6. Specifications Features:

Integral switching circuit limits power consumption to measurement cycle

Compatible with Campbell Scientific CRBasic data loggers: CR200(X) series, CR300 series, CR6 series, CR800 series, CR1000, CR1000X series, CR3000, CR5000, and CR9000(X)

6.1 Operating Range Pressure: 500 mb to 1100 mb

Temperature: 40 to 60 C

Humidity: non-condensing

6.2 Accuracy Total Accuracy3: 0.3 mb @ 20 C 0.6 mb @ 0 to 40 C 1 mb @ 20 to 45 C 1.5 mb @ 40 to 60 C

Linearity1: 0.25 mb @ 20 C

Hysteresis1: 0.03 mb @ 20 C

Repeatability1: 0.03 mb @ 20 C

Calibration Uncertainty2: 0.15 mb @ 20 C

Long-Term Stability: 0.1 mb per year

1 Defined as 2 standard deviation limits of end-point non-linearity, hysteresis error, or repeatability error

2 Defined as 2 standard deviation limits of inaccuracy of the working standard at 1000 mb in comparison to international standards (NIST)

3 Defined as the root sum of the squares (RSS) of end-point non-linearity, hysteresis error, repeatability error and calibration uncertainty at room temperature

CS106 Barometric Pressure Sensor

5

6.3 General Dimensions: 9.7 x 6.8 x 2.8 cm (3.8 x 2.7 x 1.1 in)

Weight: 90 g (3.2 oz)

Housing Material: ABS/PC blend

Supply Voltage: 10 to 30 VDC

Supply Voltage Control: When the internal jumper is closed, the CS106 is on continuously. When the jumper is open, the CS106 can be turned on/off with 5 VDC/0 VDC.

Supply Voltage Sensitivity: negligible

Current Consumption: <4 mA (active); <1 A (quiescent)

Output Voltage: 0 to 2.5 VDC

Warm Up Time: 1 s

Pressure Fitting: barbed fitting for 1/8 in I.D. tubing

Overpressure Limit: 2000 mb

7. Installation If you are programming your data logger with Short Cut, skip Section 7.3, Wiring (p. 7), and Section 7.4, Programming (p. 9). Short Cut does this work for you. See Section 4, QuickStart (p. 1), for a Short Cut tutorial.

7.1 Jumper Settings A jumper, located underneath the plastic cover of the barometer, selects whether the CS106 is in the shutdown or normal mode (FIGURE 7-1). When the jumper is not installed, the CS106 is in shutdown mode and the data logger turns the CS106 on and off with a control or excitation terminal; to use the excitation terminal the data logger must be able to provide an excitation voltage of 5 VDC. When the jumper is installed, the CS106 is in normal mode and powered continuously.

CS106s shipped from Campbell Scientific are configured for shutdown mode (jumper open).

NOTE

CS106 Barometric Pressure Sensor

6

FIGURE 7-1. CS106 jumper settings

7.2 Mounting in the Enclosure To prevent condensation, install the sensor in an environmentally protected enclosure, complete with desiccant. Change desiccant at regular intervals.

Failure to protect the sensor from condensation may result in permanent damage.

The CS106 is typically mounted in a Campbell Scientific enclosure next to the data logger. Campbell Scientific also offers the ENC100 for situations where it is desirable to house the CS106 in its own enclosure (see FIGURE 7-2). The ENC100 is a 6.7-inch by 5.5-inch by 3.7-inch enclosure that includes a compression fitting for cable entry, a vent for equalization with the atmosphere, a backplate for mounting the CS106, and hardware for mounting the ENC100 to a tripod, tower, or pole.

CAUTION

Jumper installed (powered continuously)

Jumper not installed (shutdown mode)

CS106 Barometric Pressure Sensor

7

FIGURE 7-2. ENC100 is a very small enclosure that can house one CS106

For the sensor to detect the external ambient pressure, the enclosure must vent to the atmosphere (not be hermetically sealed), which may require the addition of a vent hole on the outer wall. In this situation, do not make the hole on one of the vertical side walls, as wind blowing around it can cause transient changes in pressure.

Mount the sensor with the pneumatic connector pointing vertically downwards to prevent condensation collecting in the pressure cavity, and also to ensure that water cannot enter the sensor.

7.3 Wiring 7.3.1 Data Logger Connection

Remove the yellow warning label from the pigtails before connecting the barometer to the data logger. The warning label emphasizes the importance of properly connecting the barometer to the data logger. Wiring is shown in FIGURE 7-3 and Table 7-1.

CS106 Barometric Pressure Sensor

8

FIGURE 7-3. CS106 wiring diagram

TABLE 7-1. Wire Color, CS106 Connection, and Data Logger Connection

Wire Color CS106 Terminal Data Logger Terminal,

Single-Ended Measurement Data Logger Terminal,

Differential Measurement

Blue VOUT U configured for single-ended

analog input1, SE (single-ended, analog-voltage input)

U configured for differential high1, DIFF H (differential high, analog-

voltage input)

Yellow AGND (analog ground) U configured for differential low1, DIFF L (differential low, analog-

voltage input) Black GND G2 G2

Green EXT TRIG U configured to turn power on/off1, C (control)

U configured to turn power on/off1, C (control)

Red SUPPLY 12V 12V

Shield Shield 1 U terminals are automatically configured by the measurement instruction. 2 For the CR9000(X), the black wire connects to .

Blue Pressure (VOUT)

Yellow Signal Ground (AGND)

Red 12 VDC (SUPPLY)

Black Power Ground (GND)

Green Control (EXT. TRIG)

Clear Shield (G or AGND)

CS106 Barometric Pressure Sensor

9

Improper wiring may damage the CS106 beyond repair.

7.3.2 5-pin Screw Terminal Plug Connector The data logger connects to the CS106 by using a 5-pin screw terminal plug connector. This connector is removable and may be replaced. The replacement connector may come with a connector key attached to ensure that the connector is plugged into the CS106 right side up (see FIGURE 7-4). When the connector is right side up, it will easily plug into the barometer.

FIGURE 7-4. Connector key attached to 5-pin screw terminal plug connector

A 5-pin screw terminal that is plugged in upside down will damage the sensorperhaps beyond repair.

7.4 Programming Short Cut is the best source for up-to-date data logger programming code.

If your data acquisition requirements are simple, you can probably create and maintain a data logger program exclusively with Short Cut. If your data acquisition needs are more complex, the files that Short Cut creates are a great source for programming code to start a new program or add to an existing custom program.

Short Cut cannot edit programs after they are imported and edited in CRBasic Editor.

A Short Cut tutorial is available in Section 4, QuickStart (p. 1). If you wish to import Short Cut code into CRBasic Editor to create or add to a customized program, follow the procedure in Appendix A, Importing Short Cut Code Into CRBasic Editor (p. A-1). Programming basics for CRBasic data loggers are provided in the following sections; more detailed information about multiplier and offset calculations, conversion factors, long cable lengths, resolution, and correcting pressure to sea level is provided in Section 8, Operations (p. 10). Complete program examples for select data loggers can be found in Appendix B, Example Programs (p. B-1).

WARNING

WARNING

NOTE

CS106 Barometric Pressure Sensor

10

7.4.1 CRBasic Instructions

The VoltSE() measurement instruction programs the data logger to measure the CS106.

VoltSE(Dest, Reps, Range, SEChan, MeasOff, SettlingTime, Integ/FNotch, Multiplier, Offset)

At sea level, a multiplier of 0.24 and an offset of 500 will report the barometric pressure in mbar or hPa. The offset will need to be adjusted if the barometer is not at sea level (see Section 8.5, Correcting Pressure to Sea Level (p. 11)). If different barometric pressure units are desired, see Section 8.2, Conversion Factors (p. 11).

Often the TimeIntoInterval() instruction is used to only power the barometer while making the measurements. Atmospheric pressure changes little with time. In most weather station applications, measuring the barometer pressure once an hour is adequate. See Appendix B, Example Programs (p. B-1), for more information.

8. Operations 8.1 Multiplier and Offset Calculation

The multiplier and offset in the VoltSE() CRBasic instruction convert millivolts to millibar or hPa. The output from the sensor is 0 to 2.5 V or 0 to 2500 mV and the sensor operating range is from 500 to 1100 mbars (hPa). Equation 1 uses these values to calculate the multiplier:

= 1100 500

2500 0 =

600 2500

= 0.24

The offset is the barometric value at sea level (see Eq 2).

Offset = 500 (mbar or hPa )

The final result according to FIGURE 8-1 is:

= 0.24

+ 500

FIGURE 8-1. Point slope graph

(1)

(2)

CS106 Barometric Pressure Sensor

11

8.2 Conversion Factors In the example program, the pressure is reported in millibars (mb). To report pressure in different units, multiply the measured pressure by the appropriate conversion factor (TABLE 8-1).

TABLE 8-1. Conversion Factors for Alternative Pressure Units

To Find Multiply by hPa or mb 1.0

kPa 0.1 mm of Hg 0.75006 in of Hg 0.02953

Psi 0.0145 Atm 0.00099 Torr 0.75006

Use an expression in the CRBasic program to convert the values. For example, the following expression converts the pressure to mm of Hg:

BP_mmHg=BP*0.75006

8.3 Long Cable Lengths The CS106 cable has a 0.06 mV/foot voltage drop, which raises the barometric reading by approximately 1.44 mb per 100 feet.

For cable lengths greater than 20 feet, use the differential instruction (VoltDiff()) to measure the CS106.

8.4 Output Resolution To retain 0.01 mb resolution, use the IEEE4 format; for example, Sample (1,BP_mmHG,IEEE4). The default data output format for CR200(X)- series data logger is IEEE4. See Appendix B, Example Programs (p. B-1), for more information.

8.5 Correcting Pressure to Sea Level The National Weather Service, most airports, radio stations, and television stations adjust the atmospheric pressure to a common reference (sea level). Equation 3 can be used to find the difference in pressure between the sea level and the site. That value (dP) is then added to the offset (500 mb in our example programs) in the measurement instruction. U. S. Standard Atmosphere and dry air were assumed when Equation 3 was derived (Wallace, J. M. and P. V. Hobbes, 1977: Atmospheric Science: An Introductory Survey, Academic Press, pp. 59-61).

= 1013.25 1 1

44307.69231 5.25328

The value dP is in millibars and the site elevation, E, is in meters. Add dP value to the offset in the measurement instruction.

(3)

CS106 Barometric Pressure Sensor

12

Use Equation (4) to convert feet to meters.

() = ()

3.281/

The corrections involved can be significant. For example, at 1000 mb and 20 C, barometric pressure will decrease by 1.1 mb for every 10 meter increase in altitude.

9. Maintenance and Calibration All factory repairs and recalibrations require a returned material authorization (RMA) and completion of the Declaration of Hazardous Material and Decontamination form. Refer to the Assistance page at the beginning of this manual for more information.

Since the sensor is semi-sealed, minimum maintenance is required:

Visually inspect the cable connection to ensure it is clean and dry. Visually inspect the casing for damage. Ensure that the pneumatic connection and pipe are secure and

undamaged.

The external case can be cleaned with a damp, lint-free cloth and a mild detergent solution.

Vaisala recommends recalibration every two years under normal use. In areas where a lot of contaminants are present, recalibration every year is recommended.

A replacement five terminal connector is available from: www.campbellsci.com/order/p16004.

The CS106 is sensitive to static when the backplate is removed. To avoid damage, take adequate anti-static measures when handling.

NOTE

CAUTION

(4)

A-1

Appendix A. Importing Short Cut Code Into CRBasic Editor

Short Cut creates a .DEF file that contains wiring and memory usage information, and a program file that can be imported into the CRBasic Editor. By default, these files reside in the C:\campbellsci\SCWin folder.

Import Short Cut program file and wiring information into CRBasic Editor:

1. Create the Short Cut program following the procedure in Section 4, QuickStart (p. 1). After saving the Short Cut program, click the Advanced tab then the CRBasic Editor button. A program file with a generic name will open in CRBasic. Provide a meaningful name and save the CRBasic program. This program can now be edited for additional refinement.

Once the file is edited with CRBasic Editor, Short Cut can no longer be used to edit the program it created.

2. To add the Short Cut wiring information into the new CRBasic program, open the .DEF file located in the C:\campbellsci\SCWin folder, and copy the wiring information, which is at the beginning of the .DEF file.

3. Go into the CRBasic program and paste the wiring information into it.

4. In the CRBasic program, highlight the wiring information, right-click, and select Comment Block. This adds an apostrophe (') to the beginning of each of the highlighted lines, which instructs the data logger compiler to ignore those lines when compiling. The Comment Block feature is demonstrated at about 5:10 in the CRBasic | Features video .

NOTE

B-1

Appendix B. Example Programs B.1 CR1000X Program Using Sequential Mode

This CR1000X program uses the sequential mode, which is the simplest mode, and can be used for most meteorological applications. Although the example is for the CR1000X, other CRBasic data loggers are programmed similarly.

In the example, the CR1000X measures the CS106 once an hour. A control terminal turns on the CS106 one minute before the top of the hour. On the hour, the data logger measures the CS106, then turns the CS106 off. This example assumes that the jumper is in the default position (open).

The sensor has a warmup time of 1 second. However, powering the sensor for 1 minute instead of 1 second ensures that processing is not delayed.

CRBasic Example B-1. CR1000X Program Using Sequential Mode

'CR1000X

'Declare Variables and Units Public BattV Public PTemp_C Public BP Public BP_mmHg

Units BattV=Volts Units PTemp_C=Deg C Units BP = hPa Units BP_mmHg=mmHg

'Define Data Tables DataTable(Hourly,True,-1) DataInterval(0,60,Min,10) Sample(1,BP_mmHg,IEEE4) EndTable

DataTable(Daily,True,-1) DataInterval(0,1440,Min,10) Minimum(1,BattV,FP2,False,False) EndTable

'Main Program BeginProg 'Main Scan Scan(5,Sec,1,0) 'Default Data Logger Battery Voltage measurement 'BattV' Battery(BattV) 'Default Wiring Panel Temperature measurement 'PTemp_C' PanelTemp(PTemp_C,60) 'CS106 Barometric Pressure Sensor measurement 'BP_mmHg' If TimeIntoInterval(59,60,Min) Then PortSet(C1,1) If TimeIntoInterval(0,60,Min) Then VoltSe(BP,1,mV5000,1,1,0,_60Hz,0.240,500) BP_mmHg=BP*0.75006 PortSet(C1,0) EndIf 'Call Data Tables and Store Data CallTable(Hourly) CallTable(Daily) NextScan EndProg

NOTE

Appendix B. Example Programs

B-2

B.2 CR1000X Program Using Pipeline Mode Although this example is for the CR1000X, other CRBasic data loggers are programmed similarly. In the example, the CR1000X measures the CS106 once an hour in a program that runs at 1 Hz. To keep the CR1000X running in a pipeline mode, the measurement instruction is placed outside the If statement. The measurement is made every scan, and the measured value is first written into a temporary variable called CS106_temp. Once the CS106 is turned on one minute before the hour, the CS106 starts to make the correct pressure measurements. At the top of the hour, the correct value is copied into the current variable called pressure, and the sensor is turned off immediately.

The sensor has a warmup time of 1 second. However, powering the sensor for 1 minute instead of 1 second ensures that processing is not delayed and does not significantly increase the current drain.

The integration parameter for the VoltSE() instruction is 60. However, for Eddy Covariance programs or other data logger programs that are executed at a higher frequency, the fnotch parameter should be 15000 instead of 60 or 50. This prevents skipped scans.

CRBasic Example B-2. CR1000X Program Using Pipeline Mode

'CR1000X Data Logger Public CS106_temp, pressure Units pressure = mbar DataTable(met_data,True,-1) DataInterval(0,60,min,10) Sample(1,pressure,IEEE4) EndTable BeginProg PipeLineMode Scan(1,sec,3,0) 'Measurement is made every scan outside the "If" statement VoltSE(CS106_temp,1,mV5000,1,False,0,60,0.240,500) 'Turn on CS106 one minute before the hour TimeIsBetween(59,60,60,min) WriteIO(&b1000,&b1000) 'Copy the correct value to a current variable called "pressure" at the top of the hour 'Turn off CS106 after the measurement If (TimeIntoInterval (0,60,min)) Then pressure = CS106_temp WriteIO (&b1000,&b0) EndIf CallTable met_data NextScan EndProg

NOTE

INFO

Global Sales & Support Network A worldwide network to help meet your needs

Australia Location: Garbutt, QLD Australia Phone: 61.7.4401.7700 Email: info@campbellsci.com.au Website: www.campbellsci.com.au

Brazil Location: So Paulo, SP Brazil Phone: 11.3732.3399 Email: vendas@campbellsci.com.br Website: www.campbellsci.com.br

Canada Location: Edmonton, AB Canada Phone: 780.454.2505 Email: dataloggers@campbellsci.ca Website: www.campbellsci.ca

China Location: Beijing, P. R. China Phone: 86.10.6561.0080 Email: info@campbellsci.com.cn Website: www.campbellsci.com

Costa Rica Location: San Pedro, Costa Rica Phone: 506.2280.1564 Email: info@campbellsci.cc Website: www.campbellsci.cc

France Location: Vincennes, France Phone: 0033.0.1.56.45.15.20 Email: info@campbellsci.fr Website: www.campbellsci.fr

Germany Location: Bremen, Germany Phone: 49.0.421.460974.0 Email: info@campbellsci.de Website: www.campbellsci.de

South Africa Location: Stellenbosch, South Africa Phone: 27.21.8809960 Email: sales@campbellsci.co.za Website: www.campbellsci.co.za

Southeast Asia Location: Bangkok, Thailand Phone: 66.2.719.3399 Email: thitipongc@campbellsci.asia Website: www.campbellsc

Manualsnet FAQs

If you want to find out how the CS106 Campbell Scientific works, you can view and download the Campbell Scientific CS106 Sensor Product Manual on the Manualsnet website.

Yes, we have the Product Manual for Campbell Scientific CS106 as well as other Campbell Scientific manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Product Manual should include all the details that are needed to use a Campbell Scientific CS106. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Campbell Scientific CS106 Sensor Product Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Campbell Scientific CS106 Sensor Product Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Campbell Scientific CS106 Sensor Product Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Campbell Scientific CS106 Sensor Product Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Campbell Scientific CS106 Sensor Product Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.