COM210 Telephone Modem Revision: 10/05

C o p y r i g h t ( c ) 1 9 9 7 - 2 0 0 5 C a m p b e l l S c i e n t i f i c , I n c .

Warranty and Assistance The COM210 TELEPHONE MODEM is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective products. The customer shall assume all costs of removing, reinstalling, and shipping defective products to CAMPBELL SCIENTIFIC, INC. CAMPBELL SCIENTIFIC, INC. will return such products by surface carrier prepaid. This warranty shall not apply to any CAMPBELL SCIENTIFIC, INC. products which have been subjected to modification, misuse, neglect, accidents of nature, or shipping damage. This warranty is in lieu of all other warranties, expressed or implied, including warranties of merchantability or fitness for a particular purpose. CAMPBELL SCIENTIFIC, INC. is not liable for special, indirect, incidental, or consequential damages.

Products may not be returned without prior authorization. The following contact information is for US and International customers residing in countries served by Campbell Scientific, Inc. directly. Affiliate companies handle repairs for customers within their territories. Please visit www.campbellsci.com to determine which Campbell Scientific company serves your country. To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) 753-2342. After an applications engineer determines the nature of the problem, an RMA number will be issued. Please write this number clearly on the outside of the shipping container. CAMPBELL SCIENTIFIC's shipping address is:

CAMPBELL SCIENTIFIC, INC. RMA#_____ 815 West 1800 North Logan, Utah 84321-1784

CAMPBELL SCIENTIFIC, INC. does not accept collect calls.

i

COM210 Telephone Modem Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat bookmarks tab for links to specific sections.

1. Introduction..................................................................1 1.1 General Description ..................................................................................1 1.2 Computer Requirements ...........................................................................1

2. Specifications ..............................................................1

3. Installation....................................................................2 3.1 Connecting to Datalogger .........................................................................2 3.2 Connecting to Earth Ground.....................................................................3 3.3 Telephone to MD485 or Telephone to RF Systems..................................3 3.4 Telephone Service ....................................................................................3

4. Troubleshooting ..........................................................6

5. Modem Settings in Non-Volatile Memory ..................7

Appendixes

A. Modifying the Non-Volatile Memory ...................... A-1 A.1 Hardware Connection to COM210 ..................................................... A-1 A.2 Remote Communication to the COM210 ........................................... A-2 A.3 Hayes AT Command Summary .......................................................... A-4

B. CS I/O Connection................................................... B-1 B.1 CS I/O 9 Pin Connection......................................................................B-1

C. Theory of Operation ................................................ C-1 C.1 Theory of Operation.............................................................................C-1

D. FCC Warning to Users of Class A Computing Devices.............................. D-1

E. IC Information .......................................................... E-1

COM210 Telephone Modem Table of Contents

ii

List of Figures 1. COM210 .................................................................................................... 1 2. CR1000 and COM210 Using Remote Telephone Line ............................. 4 3. CR10X with CR10 Wiring Panel and COM210 Using

RJ11C Telephone Jack............................................................................ 5 A-1. LoggerNet Screen .............................................................................. A-2 A-2. COM210 to Computer Connection.................................................... A-3 B-1. CS I/O Pin Out ................................................................................... B-1

List of Tables 1. Dataloggers that Require Direct 12 VDC Connection to COM210........... 3

1

COM210 Telephone Modem

1. Introduction

1.1 General Description The COM210 Modem is a 9600 baud phone modem employing the Hayes AT command set. Its primary use is as a remote site phone modem connected to a CSI datalogger. The modem is powered and enabled by the battery-powered datalogger. When not active, the COM210 draws less than 120 A from the dataloggers 12 VDC output. The COM210 is a drop in replacement for the COM200.

The COM210 is connected to a CSI datalogger by using a 9-pin subminiature D connector cable. This is the same 9-pin CS I/O connection common to all Campbell Scientific dataloggers (except the CR200 series). This is not an RS- 232 connection. Appendix B describes the configuration of this connector.

The COM210 can be used as an originate modem at the datalogger site. For Edlog dataloggers (e.g., CR510, CR10X, CR23X), use Instruction 97 to program the datalogger to originate a call to the computer; refer to your datalogger manual for a detailed description of Instruction 97. CRBasic dataloggers (e.g., CR1000, CR3000) use the Dial Sequence and Dial Modem instructions.

The COM210 features a built-in speaker to allow monitoring of calling and connection operations. See Appendix A.3 for the Hayes AT commands that affect the speaker on/off and volume settings.

T IP

R IN

G

G N

D

CAMPBELLSCIENTIFICINC. COM210 MODEM

MADE IN USA

S/N 1002

Complies with Part 68, FCC rules. FCC Registration No. B9QUSA-31402-MM-T

Ringer Equivalence 0.9B.Required Connector USOC RJ11C. Canadian Load No. 5

This equipment complies with the requirements in Part 15 of FCC Rules for Class A

computing device. Operation of this equipment in a residential area may cause

unacceptable interference to radio and TV reception requiring the operator to take

whatever steps are necessary to correct the interference.

12VG

FIGURE 1. COM210

1.2 Computer Requirements A Hayes-compatible modem is used at the computer site with Campbell Scientific computer software to call the datalogger attached to the COM210. The computers modem must be configured to the proper settings using the modem initialization strings listed in the software programs.

COM210 Telephone Modem

2

2. Specifications Bell 212A, CCITT V.22, and CCITT V.32 compatible

Full duplex at 9600 (default setting) and 1200 baud to datalogger

V.42 LAPM and MNP2-4 error correction

Hayes AT command set

On-board speaker

RJ-11C telephone jack

FCC and IC (formerly known as DOC) approval

Pulse or tone dialing

Current drain: 120 A quiescent, 160 mA active

Direct connection to and powered by CSI dataloggers

Supply requirements: 12 VDC regulated power supply

Internally switches 12 VDC external power minimizing current drain

Logic levels: below 1.5 V inputs a low state and above 3.5 V inputs a high state. A low voltage level on the TX data input (pin 9) and RX data output (pin 4) represents a mark

Operational temperature: -25oC to +50oC standard (Extended operational temperature range of -55C to +85C is available at time of purchase.)

Size: 5.2 x 1.7 x 3.6 // 13.1 x 4.3 x 9.2 cm

Weight: 0.75 lbs // 0.34 kg

3. Installation The COM210 is designed to be used with standard analog telephone lines. It will not work with a digital telephone line. Connection to telephone-company- provided coin service (central office implemented systems) is prohibited. Connection to party line service is subject to state tariffs.

3.1 Connecting to Datalogger Connect the cable from the telephone RJ11C jack to the modem as shown in Figure 3. If the telephone company has not installed surge protection in the telephone line (no RJ11C jack), one must install surge protection (CSI item number 6362 or 4330) and connect the ring and tip terminal blocks as shown in Figure 2.

COM210 Telephone Modem

3

Current Campbell Scientific dataloggers provide 12 VDC to the COM210 via the SC12 cable (Figure 2). Older dataloggers do not provide 12 VDC on the datalogger's CS I/O 9 pin connector. When used with the older dataloggers listed in Table1, 12 VDC and ground need to be connected via the green power connector on the side of the COM210 (see Figure 3).

Table 1. Dataloggers that Require Direct

12 VDC Connection to COM210

CR10(X) with silver wiring panel CR10(X) with black CR10 wiring panel (P/N 8032) 21X(L)serial number 13,442 or lower CR500serial number 1764 or lower CR7700X serial number 2778 or lower BDR301 and BDR320

3.2 Connecting to Earth Ground Connect the green 14 awg grounding wire (provided with the COM210) to the grounding terminal (GND) on the COM210 and to the enclosures earth ground connection. If the site does not have a grounded enclosure, then connect the ground wire directly to an earth ground connection. The datalogger ground should also be tied to the earth ground.

The modem must be grounded for its transient protection to work.

3.3 Telephone to MD485 or Telephone to RF Systems Telephone to MD485 or telephone to radio systems can be utilized for communicating with multiple dataloggers through one telephone line. Nothing additional or special is required for the telephone part of the link. See the MD485 or RF Manuals for complete information on their special requirements.

3.4 Telephone Service The goal of the telephone company is to provide you with the best service it can. In order to do this, it may occasionally be necessary for them to make changes in their equipment, operations, or procedures. If you have any questions about your telephone line, such as how many pieces of equipment you can connect to it, the telephone company will provide this information upon request. If the telephone company requests information concerning the equipment which you have connected to your telephone line, the FCC registration number and the ringer equivalence number (REN) of the COM210 are listed on its label. Additional technical information from the FCC and IC on the COM210 is available in Appendix D and E, respectively.

CAUTION

COM210 Telephone Modem

4

SE 1 2 3 4 5 6 7 8

H 1 2 3 4

L DIFF

H EX 1

H LH LL P2P1

12VG

DC ONLY CAUTION

LUG GROUND

POWER IN

WIRING PANEL CR1000

PERIPHERAL PORT

RS-232 (Not Isolated)

SN:

CS I/O

MADE IN USA

11109SE 15 1613 1412

HL DIFF

H EX 2

H LH LL EX 35 6 7 8

SW -1

2

5V 12 V

12 V

C 5

C 4

G G G G C 1

C 2

C 3

G GC 6

C 7

C 8

Tx COM1

Rx Tx Rx Tx Rx Tx Rx COM2 COM3 COM4POWER OUT

SDM

G 12V

CAMPBELL SCIENTIFIC INC.

COM210 MODEM

S/N 0002 MADE IN USA

G N

D

R IN

G

TI P

Burial Phone Cable

Blue = Ring

Blue/White = TipPhone Line Transient Protector (Model 6362 or 2372-01)

SC12 Cable Complies with Part 68, FCC rules. FCC Registration No. B9QUSA-75378-MM-T Ringer Equivalence 0.9B. Required Connector USOC RJ11C.

This equipment complies with the requirements in Part 15 of FCC Rules for Class A computing device. Operation of this equipment in a residential area may cause unacceptable interference to radio and TV reception requiring the operator to take whatever steps are necessary to correct the interference.

Earth Ground

FIGURE 2. CR1000 and COM210 Using Remote Telephone Line

COM210 Telephone Modem

5

T IP

R IN

G

G N

D

CAMPBELLSCIENTIFICINC. COM210 MODEM

MADE IN USA

S/N 1002

Complies with Part 68, FCC rules. FCC Registration No. B9QUSA-31402-MM-T

Ringer Equivalence 0.9B.Required Connector USOC RJ11C. Canadian Load No. 5

This equipment complies with the requirements in Part 15 of FCC Rules for Class A

computing device. Operation of this equipment in a residential area may cause

unacceptable interference to radio and TV reception requiring the operator to take

whatever steps are necessary to correct the interference.

12VG

CAMPBELL SCIENTIFIC INC.

CR10 MADE IN USA

WIRING PANEL NO.

EARTH

DIFF

SE

AG H L AG H L AG H L AG GGE3 AG 4 5 6

7 8 9 10 11 12

G G G G 12V 12V

SWITCHED 12V

G 12V POWER

IN

SERIAL I/O

SE

DIFF AG H L AG H L AG H L AG GGE1 E2 1 2 3

1 2 3 4 5 6

G 5V 5V P1 P2 C8 C7 C6 C5 C4 C3 C2 C1

CONTROL 12V

SWITCHED

To Earth Ground

14 AWG Ground Wire SC12 Cable

Telephone Wall Jack

Red Black

(Ground) (+12v)

FIGURE 3. CR10X with CR10 Wiring Panel and COM210 Using RJ11C Telephone Jack

COM210 Telephone Modem

6

4. Troubleshooting When the Campbell Scientific software cannot establish a link to the remote datalogger that is connected to the COM210, check the following:

1) Verify the modem initialization settings have been changed for the specific calling modem on the computer. See software manual and/or help screens for more information.

2) Verify nothing else is using the same COM port on the computer. Even if a program is minimized in windows, it may have a lock on the COM port. Some notebook computers do not automatically activate the COM ports. Verify the COM port you are using is activated.

3) The Campbell Scientific software will display an activity of communication as the link is being established. Assuming the above items are O.K., the software should display in the activity window/screen something such as ATDT#######. Where the #### is the telephone number listed in the dialing path of the software for the datalogger you are trying to call. The local modem attached to the computer will respond back to the computer with result codes showing how the call is progressing. These result codes can be either numeric (0, 1, 2, etc.) or "verbose" ("OK", "CONNECT", "RING", etc.). Prior to PC208W 3.0, our software expected numeric result codes. PC208W 3.x and LoggerNet uses "verbose" result codes to determine call progress. The V command is used to select between numeric or verbose result codes. Depending on the version of PC208W being used, the initialization string for the modem may need to be changed for the appropriate form of result codes. The result code returned may indicate why the call is unsuccessful. Appendix A has a list of possible result codes.

4) Can you attach a normal analog telephone to the line and make a call out? If not, contact your local telephone company. If you can make a call out but the connection is poor or faint, contact your local telephone company.

5) Verify the COM210 is receiving 12 VDC. If the COM210 is receiving 12 VDC from a separate power supply instead of the datalogger, is the ground of the separate power supply connected to the dataloggers ground?

6) Verify the COM210 is the only Modem Enable device connected to the datalogger. Other common Campbell Scientific modem enable devices are the SC32B, some RF modems, and the MD485.

7) Verify the datalogger is turned on.

COM210 Telephone Modem

7

To comply with FCC rules and regulations, all repairs on the COM210 modem must be performed by Campbell Scientific, Inc. or an authorized agent of Campbell Scientific, Inc. For assistance in installation, troubleshooting, or for repair, contact Campbell Scientific:

Campbell Scientific, Inc. 815 West 1800 North Logan, Utah 84321-1784 Telephone: (435) 753-2342 Fax: (435) 750-9540 Web site: www.campbellsci.com

5. Modem Settings in Non-Volatile Memory The COM210 comes from the factory with the appropriate settings for most applications. It is programmed to answer the call as soon as it detects the call.

One may modify the COM210s settings in non-volatile memory using Hayes AT commands. Appendix A describes the procedures and commands required to make the changes described in this section.

Some of the settings one may change are:

Disable auto-answer: This option is used only when the modem is not to answer a call. For example, the COM210 is connected to a telephone line that is to be used part time for voice communication. In this situation it is best to have the datalogger call the computer.

Speaker On/Off and Volume: Default settings have the speaker on during call establishment only and set to a low volume. To conserve on current drain during the connection time or so one doesnt hear the speaker, one may turn the speaker completely off. When one wants to hear the speaker better than the default low volume setting, one may change it to a higher volume level.

Answer on Xth ring: This option is used when the modem is sharing a line and you only want it to answer after a specified number of rings. For example, the COM210 is sharing a line with people at an office. It can be programmed to only answer after the third ring. If the PC calls when the office is closed and no one answers the phone after three rings, the datalogger will pick it up.

Change telephone system types: Change from the Bell 212A (U.S. and Canada) system to a CCITT V.32 (foreign, 9600 baud) or CCITT V.22 (foreign, 1200 baud) system. This does not mean that the COM210 is tested and approved for all foreign countries.

CCITT is an international consultative committee that sets international communications usage standards. V.32 and V.22 are standards that the COM210 meets.

This is a blank page.

COM210 Telephone Modem

8

A-1

Appendix A. Modifying the Non-Volatile Memory

To modify the COM210s settings, one must communicate directly to the COM210. This may be accomplished by using one of the two methods below.

Changing any of the modem's settings may result in communication problems. After changing the settings, try the modem locally before installing it at a remote location. To speed problem resolution when contacting Campbell Scientific for support, please inform us of any modem setting changes that have been made.

A.1 Hardware Connection to COM210 Connect the COM210 to a computer using an SC532A interface (Figure A-2). The computer software (LoggerNet) used to communicate with the COM210 must raise the RS-232 DTR and set RTS low.

The following example shows how to change the COM210 to answer on the 3rd ring.

First attach a series of Generic devices ending with a datalogger to a COM port. On the first Generic device check Raise DTR and select The RTS line will be lowered (see Figure A-1). Now send the following commands to the COM210 through the LoggerNet terminal emulator (select device Generic_2 and 9600 baud in the terminal emulator).

ATS0=3 AT&W0

CAUTION

Appendix A. Modifying the Non-Volatile Memory

A-2

FIGURE A-1. LoggerNet Screen

A.2 Remote Communication to the COM210 To remotely communicate with the COM210, program the datalogger to initiate a call to it using a program similar to the Example Program 1.* After this program runs once, the modem is now programmed and the actual program one wants to run may now be downloaded to the datalogger.

*Please note that this program requires that the option code for an RF modem be used instead of the normal phone modem option.

Appendix A. Modifying the Non-Volatile Memory

A-3

9227

SC532A RS232 to CS I/O

POWER

MADE IN USA

SN:

PER IPH

ER A

L

PC

Logan, Utah

T IP

R IN

G

G N

D

CAMPBELLSCIENTIFICINC. COM210 MODEM

MADE IN USA

S/N 1002

Complies with Part 68, FCC rules. FCC Registration No. B9QUSA-31402-MM-T

Ringer Equivalence 0.9B.Required Connector USOC RJ11C. Canadian Load No. 5

This equipment complies with the requirements in Part 15 of FCC Rules for Class A

computing device. Operation of this equipment in a residential area may cause

unacceptable interference to radio and TV reception requiring the operator to take

whatever steps are necessary to correct the interference.

12VG

SC12 Cable

Red

Black

To 12V

To GND

FIGURE A-2. COM210 to Computer Connection

Example Program 1

*Table 1 Program 01: 1 Execution Interval (seconds) 1: Initiate Telecommunications (P97) 1: 02 RF Modem/9600 Baud 2: 1 Disabled when User Flag 1 is High 3: 20 Seconds Call Time Limit 4: 0 Seconds Before Fast Retry 5: 0 Fast Retries 6: 0 Minutes before Slow Retry 7: 1 Failures Loc [ Failure ] 8: 0 Data Logger ID 2: Extended Parameters (P63) 1: 65 Option ;A 2: 84 Option ;T 3: 83 Option ;S 4: 48 Option ;0 5: 61 Option ;= 6: 50 Option ;2 results in 3 rings (rings = n + 1) 7: 38 Option ;& 8: 87 Option ;W

Appendix A. Modifying the Non-Volatile Memory

A-4

3: Extended Parameters (P63) 1: 48 Option ;0 2: 68 Option ;D 3: 84 Option ;T 4: 13 Option 5: 00 Option 6: 00 Option 7: 00 Option 8: 00 Option

After sending above program, disconnect from datalogger and wait 30 seconds, allowing program to finish, before connecting again.

A.3 Hayes AT Command Summary This manual does not attempt to be a primer on the Hayes AT command set. The commands are, therefore, only summarized below. For most applications, these commands will not need to be used. Except as noted, all commands should begin with an AT and end with a carriage return (hit the [Enter] key). There are no O as in Oscar commands, only 0 as in Zero commands. All commands must be issued as CAPITAL letters.

COMMANDS TO CHANGE DEFAULT MODES:

B1 (default) CCITT V.32 (9600 baud), Bell 212A (1200 baud), and Bell 103 (300 baud)

B0 CCITT V.32 (9600 baud), CCITT V.22 (1200 baud), and CCITT V.21 (300 baud)

L0 Lowest speaker volume L1 (default) Low speaker volume L2 Medium speaker volume L3 High speaker volume M0 Speaker always off M1 (default) Speaker on during call establishment M2 Speak on during entire call session S0=0 Disable Auto Answer S0=1 (default) Answer on second ring S0=2 Answer on third ring S0=n Answer on (n + 1) ring. (maximum n is 2) &F Restore factory defaults &W0 Store current profile as Profile to load on power up &V Display the current profile to the screen

Appendix A. Modifying the Non-Volatile Memory

A-5

RESULT CODES:

0 OK 1 Connect 2 Ring 3 No Carrier 4 Error 5 Connect 1200 Baud 6 No Dial Tone 7 Busy 8 No Answer 12 Connect 9600 Baud 13 Connect 9600/14400 Baud 17 Connect 9600 Baud

If more than three rings are specified (first P63 parameter 6 > 50), the datalogger may time out before the modem answers; communication will never be established! It is possible in some conditions to allow more than three rings. Consult a Campbell Scientific applications engineer about optimizing modem negotiations before trying this and be sure to try the set up locally before installing at a remote location.

CAUTION

Appendix A. Modifying the Non-Volatile Memory

A-6

This is a blank page.

B-1

Appendix B. CS I/O Connection

B.1 CS I/O 9-Pin Connection The pin out of the connector is shown in Figure B-1. The direction of the signal relative to the modem is shown in parenthesis. Unless specified otherwise, all levels are 0 V for logic low, 5 V for logic high.

FIGURE B-1. CS I/O Pin Out

1. (input) +5 VDC supply. Not used by COM210.

2. (input) Ground

3. (output) Ring - a logic high signifies a ring signal has been detected

4. (output) RX Data - serial data from COM210

5. (input) Modem Enable - a logic high internally switches power to the modem. A logic low internally shuts off power to the modem.

6. (input) Serial Device Enable - a logic high disables communication with the modem without removing power or changing the modem's mode.

7. (input) SDC clock. Not used by COM210.

8. (input) +12 VDC supply

9. (input) TX Data - serial data to COM210

This is a blank page.

C-1

Appendix C. Theory of Operation

C.1 Theory of Operation The COM210 modem is used to transmit data over bandwidth-limited channels such as telephone lines by modulating audio tones. The COM210 uses various modulation schemes including FSK (Frequency Shift Keying), TCM (Trellis Coded Modulation), QAM (Quadrature Amplitude Modulation), and DPSK (Differential Phase Shift Keying).

The telephone company gives a 40 to 150 VRMS, 20 Hz signal on the telephone lines to signify a ring, which is typically on for two seconds and off for four seconds. The COM210 is supplied with 12 V from the dataloggers CS I/O connector or from the COM210s external power connector. The 12 V is then regulated to +5 V to give power to the ring detect circuitry. The ring detection circuitry is continuously powered but draws less than 2 A. The ring signal is passed on to the datalogger through an opto-coupler. The datalogger responds to a ring by raising the Modem Enable line, which internally switches the regulated +5 V supply to the rest of the modems circuitry.

The modem then answers and remains off-hook until it loses the carrier or the datalogger lowers the Modem Enable line. The datalogger lowers the Modem Enable line by remote command or after 40 seconds in the absence of a command. When the Modem Enable line goes low, the COM210 internally removes the +5 V from the modem circuitry, dropping power to the off-hook relay and thus placing the telephone line on-hook. The COM210s ring circuitry is still powered at this time.

To reject noise common to both telephone lines and to satisfy registration requirements, the modem circuitry is electrically isolated from the telephone lines by using an opto-isolator and a coupling transformer.

This is a blank page.

D-1

Appendix D. FCC Warning to Users of Class A Computing Devices

This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a COMMERCIAL ENVIRONMENT. Operation of this equipment in a residential area may cause interference to radio and television reception. The operator must take whatever measures are necessary to correct the interference.

WARNING

This is a blank page.

E-1

Appendix E. IC Information Industry Canada (IC) was formerly known as DOC.

CP-01, Issue 8, Part I

Section 14.1 NOTICE: The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the users satisfaction.

Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.

Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.

Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.

Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.

CP-01, Issue 8, Part I

Section 14.2 NOTICE: The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5.

NOTE

CAUTION

This is a blank page.

This is a blank page.

Campbell Scientific Companies

Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES

www.campbellsci.com info@campbellsci.com

Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450

Somerset West 7129 SOUTH AFRICA

www.csafrica.co.za sales@csafrica.co.za

Campbell Scientific Australia Pty. Ltd. (CSA) PO Box 444

Thuringowa Central QLD 4812 AUSTRALIA www.campbellsci.com.au info@campbellsci.com.au

Campbell Scientific do Brazil Ltda. (CSB) Rua Luisa Crapsi Orsi, 15 Butant

CEP: 005543-000 So Paulo SP BRAZIL www.campbellsci.com.br

suporte@campbellsci.com.br

Campbell Scientific Canada Corp. (CSC) 11564 - 149th Street NW

Edmonton, Alberta T5M 1W7 CANADA

www.campbellsci.ca dataloggers@campbellsci.ca

Campbell Scientific Ltd. (CSL) Campbell Park

80 Hathern Road Shepshed, Loughborough LE12 9GX

UNITED KINGDOM www.campbellsci.co.uk sales@campbellsci.co.uk

Campbell Scientific Ltd. (France) Miniparc du Verger - Bat. H

1, rue de Terre Neuve - Les Ulis 91967 COURTABOEUF CEDEX

Manualsnet FAQs

If you want to find out how the COM210 Campbell Scientific works, you can view and download the Campbell Scientific COM210 Modem Instruction Manual on the Manualsnet website.

Yes, we have the Instruction Manual for Campbell Scientific COM210 as well as other Campbell Scientific manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instruction Manual should include all the details that are needed to use a Campbell Scientific COM210. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Campbell Scientific COM210 Modem Instruction Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Campbell Scientific COM210 Modem Instruction Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Campbell Scientific COM210 Modem Instruction Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Campbell Scientific COM210 Modem Instruction Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Campbell Scientific COM210 Modem Instruction Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.