Contents

Campbell Scientific HUB-SDM8 Junction Box Instruction Manual PDF

1 of 10
1 of 10

Summary of Content for Campbell Scientific HUB-SDM8 Junction Box Instruction Manual PDF

HUB-SDM8 1/08

C o p y r i g h t 2 0 0 4 - 2 0 0 8 C a m p b e l l S c i e n t i f i c , I n c .

Warranty and Assistance The HUB-SDM8 is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective products. The customer shall assume all costs of removing, reinstalling, and shipping defective products to CAMPBELL SCIENTIFIC, INC. CAMPBELL SCIENTIFIC, INC. will return such products by surface carrier prepaid. This warranty shall not apply to any CAMPBELL SCIENTIFIC, INC. products which have been subjected to modification, misuse, neglect, accidents of nature, or shipping damage. This warranty is in lieu of all other warranties, expressed or implied, including warranties of merchantability or fitness for a particular purpose. CAMPBELL SCIENTIFIC, INC. is not liable for special, indirect, incidental, or consequential damages.

Products may not be returned without prior authorization. The following contact information is for US and International customers residing in countries served by Campbell Scientific, Inc. directly. Affiliate companies handle repairs for customers within their territories. Please visit www.campbellsci.com to determine which Campbell Scientific company serves your country. To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) 753-2342. After an applications engineer determines the nature of the problem, an RMA number will be issued. Please write this number clearly on the outside of the shipping container. CAMPBELL SCIENTIFIC's shipping address is:

CAMPBELL SCIENTIFIC, INC. RMA#_____ 815 West 1800 North Logan, Utah 84321-1784

CAMPBELL SCIENTIFIC, INC. does not accept collect calls.

HUB-SDM8 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat bookmarks tab for links to specific sections.

1. Introduction..................................................................1

2. HUB-SDM8 Specifications ..........................................1

3. General .........................................................................1

4. Installation and Wiring ................................................2 4.1 Wiring SDM Devices and Power Wires for Daisy-Chain ........................2

5. HUB-SDM5....................................................................3

6. Generic Junction Box..................................................3

7. Maintenance .................................................................4

Figures 1. HUB-SDM8 in a Daisy-Chain Network.....................................................2 2. HUB-SDM8 in a Daisy-Chain Network Bottom View .........................3

i

This is a blank page.

HUB-SDM8

1. Introduction The HUB-SDM8 is an 8-channel hub for SDM peripherals and power connectors, and is used to daisy-chain multiple sets of SDM (Synchronous Device for Measurement) devices to a single Campbell Scientific, Inc. datalogger, as well as run multiple power connectors using a 16 AWG wire. The HUB-SDM8 is comprised of an environmental enclosure with eight compression fittings (two larger for 16 AWG power wires) and eight terminal strips. The HUB-SDM8 can also be used as a generic junction box, or as a HUB-SDM5.

2. HUB-SDM8 Specifications Terminal Strips:

Three spring-loaded guillotine connections per terminal; two terminals in common through a jumper creates eight banks

Operating Temperature:

-55C to +85C

Operating Humidity:

Noncondensing 0% 95%

Dimensions:

Length: 17.8 cm (7.0) Width: 19.7 cm (7.75) Depth: 13.3 cm (5.25)

Weight:

0.88 kg (1.95 lbs)

3. General Inside the HUB-SDM8 enclosure are eight pairs of spring-loaded "guillotine" terminal strips, which provide connection points for individual wires. A small screwdriver is included to open the guillotines for wire entry. These terminal strips are mounted on a DIN-rail and an orange end cap separates each pair. Each pair of terminal strips is connected to each other by means of a jumper, and is used to connect up to six wires to each other.

1

HUB-SDM8

4. Installation and Wiring A U-bolt is used to mount the HUB-SDM8 to a 1.25 inch NPT pipe.

The spring-loaded guillotines are opened with a small flat blade (2.5 x 50 mm) screwdriver (p/n 8125). Orient the screwdriver blade so that the blade edge is perpendicular to the orange separators. Gently insert the small flat blade screwdriver into the square slot located next to the circular wire port until it bottoms out. For the cluster of four wire ports located on the left hand side of the HUB-SDM8, the guillotine release slot is located to the right of the wire port. For the wire ports on the right hand side of the HUB-SDM8, the guillotine release slot is located to the left of the wire port. Once the screwdriver has been completely inserted and has bottomed out, firmly press the screwdriver down until the guillotine snaps open. Insert and hold the wire as the screwdriver is removed.

4.1 Wiring SDM Devices and Power Wires for Daisy-Chain Before connecting the cable to the terminals, strip the wire insulation back to expose 1/4 inch of bare wire. Feed the cable through the bulkhead fitting. Neatly separate the wires, and connect them, using the technique described in section 4 above. The figures below show how two SDM devices (CSAT3 and LI-7500) and their power wires are connected within a daisy-chain network.

SDM In

FIGURE 1. HUB-SDM8 in a Daisy-Chain Network

CSAT3 SDM

CSAT3 Power

LI-7500 SDM

LI-7500 Power

Power In

SDM Out

Power Out

2

HUB-SDM8

To CSAT3 Power

To CSAT3 SDM

To LI-7500 SDM

To LI-7500 Power

SDM InPower In SDM Out Power Out

FIGURE 2. HUB-SDM8 in a Daisy-Chain Network Bottom View

5. HUB-SDM5 The HUB-SDM8 can provide the same function as the HUB-SDM5, which is a 5-channel hub for SDM peripherals. Use the supplied plugs to seal the unused bulkhead fittings to use the HUB-SDM8 to connect multiple SDM devices to a single Campbell Scientific, Inc. datalogger. Please refer to the HUB-SDM5 manual for connecting multiple SDM devices to a datalogger, using the HUB-SDM8.

6. Generic Junction Box The HUB-SDM8 can be used as a generic junction box. In its default configuration, six eight-conductor cables can be connected to each other. Three sixteen-conductor cables can be connected to each other by removing the jumper between the terminal strips. Use a small screwdriver to pry the jumper out.

3

HUB-SDM8

4

7. Maintenance There are no user-serviceable parts in the HUB-SDM8. Make sure that all unused bulkhead fittings are sealed with a plug and that the lid is tightly fastened.

This is a blank page.

Campbell Scientific Companies

Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES

www.campbellsci.com info@campbellsci.com

Campbell Scientific Africa Pty. Ltd. (CSAf)

PO Box 2450 Somerset West 7129

SOUTH AFRICA www.csafrica.co.za

cleroux@csafrica.co.za

Campbell Scientific Australia Pty. Ltd. (CSA) PO Box 444

Thuringowa Central QLD 4812 AUSTRALIA www.campbellsci.com.au info@campbellsci.com.au

Campbell Scientific do Brazil Ltda. (CSB)

Rua Luisa Crapsi Orsi, 15 Butant CEP: 005543-000 So Paulo SP BRAZIL

www.campbellsci.com.br suporte@campbellsci.com.br

Campbell Scientific Canada Corp. (CSC)

11564 - 149th Street NW Edmonton, Alberta T5M 1W7

CANADA www.campbellsci.ca

dataloggers@campbellsci.ca

Campbell Scientific Ltd. (CSL) Campbell Park

80 Hathern Road Shepshed, Loughborough LE12 9GX

UNITED KINGDOM www.campbellsci.co.uk sales@campbellsci.co.uk

Campbell Scientific Ltd. (France)

Miniparc du Verger - Bat. H 1, rue de Terre Neuve - Les Ulis

91967 COURTABOEUF CEDEX FRANCE

www.campbellsci.fr info@campbellsci.fr

Campbell Scientific Spain, S. L.

Psg. Font 14, local 8 08013 Barcelona

SPAIN www.camp

Manualsnet FAQs

If you want to find out how the HUB-SDM8 Campbell Scientific works, you can view and download the Campbell Scientific HUB-SDM8 Junction Box Instruction Manual on the Manualsnet website.

Yes, we have the Instruction Manual for Campbell Scientific HUB-SDM8 as well as other Campbell Scientific manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instruction Manual should include all the details that are needed to use a Campbell Scientific HUB-SDM8. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Campbell Scientific HUB-SDM8 Junction Box Instruction Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Campbell Scientific HUB-SDM8 Junction Box Instruction Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Campbell Scientific HUB-SDM8 Junction Box Instruction Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Campbell Scientific HUB-SDM8 Junction Box Instruction Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Campbell Scientific HUB-SDM8 Junction Box Instruction Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.