MD9 Multidrop Interface Revision: 5/03

C o p y r i g h t ( c ) 1 9 8 7 - 2 0 0 3 C a m p b e l l S c i e n t i f i c , I n c .

Warranty and Assistance The MD9 MULTIDROP INTERFACE is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective products. The customer shall assume all costs of removing, reinstalling, and shipping defective products to CAMPBELL SCIENTIFIC, INC. CAMPBELL SCIENTIFIC, INC. will return such products by surface carrier prepaid. This warranty shall not apply to any CAMPBELL SCIENTIFIC, INC. products which have been subjected to modification, misuse, neglect, accidents of nature, or shipping damage. This warranty is in lieu of all other warranties, expressed or implied, including warranties of merchantability or fitness for a particular purpose. CAMPBELL SCIENTIFIC, INC. is not liable for special, indirect, incidental, or consequential damages.

Products may not be returned without prior authorization. The following contact information is for US and International customers residing in countries served by Campbell Scientific, Inc. directly. Affiliate companies handle repairs for customers within their territories. Please visit www.campbellsci.com to determine which Campbell Scientific company serves your country. To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) 753-2342. After an applications engineer determines the nature of the problem, an RMA number will be issued. Please write this number clearly on the outside of the shipping container. CAMPBELL SCIENTIFIC's shipping address is:

CAMPBELL SCIENTIFIC, INC. RMA#_____ 815 West 1800 North Logan, Utah 84321-1784

CAMPBELL SCIENTIFIC, INC. does not accept collect calls.

i

MD9 Multidrop Interface Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat bookmarks tab for links to specific sections.

1. Introduction.................................................................1

2. System Description ....................................................1

3. Software and Datalogger Compatibility ....................3

4. ID and Baud Rate Selection .......................................3

5. Maximum Number of Dataloggers and Coax Length...........................................................4

6. Telephone to MD9 Network ........................................5

7. Operation.....................................................................6

A. Cable Specifications and Source References ...... A-1

B. Break/Address Timing ........................................... B-1

C. Setting the Station ID ............................................. C-1

D. SC532A ................................................................... D-1

Tables 1-1 Specifications ...........................................................................................1 4-1 ID Settings for MD9 Connected to Computer ..........................................4

Figures 1-1 MD9 Multidrop Interface .........................................................................2 2-1 System Description...................................................................................3

MD9 Multidrop Interface Table of Contents

ii

4-1 ID Switch and Baud Rate Selection Jumpers........................................... 4 6-1 Telephone to MD9 Conversion................................................................ 6 B-1 Break/Address Timing Diagram.......................................................... B-1 This is a blank page.

1

MD9 Multidrop Interface

1. Introduction The MD9 Multidrop Interface functions as a direct wire link between a computer and a Campbell Scientific datalogger via coax cable. MD9s may be networked thereby permitting a computer to address and communicate with up to 254 dataloggers. Total coax length may be up to 3 miles when fewer dataloggers are used.

With the communication link initiated and controlled by an IBM PC or clone using Campbell Scientific's telecommunication software, the operation of the MD9 in the system is transparent to the user. Call back from a remote datalogger via MD9 is not possible.

TABLE 1-1. Specifications

Size: 6.5 X 3.5 X 1.25 in.

Weight: 5 oz.

Accessories: SC12 cable, BNC "T" connector

Voltage: 5 Volts from datalogger or SC532(A)

Current: State 0 "Standby" 1.2 mA State 1 "Active" 17 mA (when transmit line drives network) 80 mA State 2 "Sleep" 3 mA State 3 Pull ring line & buffer bytes 17 mA

Temperature range: -25 to +50oC

Baud rates: 9600, 1200, 300

Carrier frequency: 1.2 MHz

Communication cable: RG59/U Coax

Cable connector: BNC

2. System Description The block diagram in Figure 2-1 depicts the connection of a computer to a network of Campbell Scientific dataloggers using MD9s.

Connection of the MD9 to the computer's RS-232 SIO port is made via the SC532(A) 9 Pin Peripheral to RS-232 Interface. The SC532(A) supplies +5 VDC power to the MD9 as well as converts the MD9's CMOS voltage levels to voltage levels consistent with RS-232 requirements. A computer with the PC201 card installed could use the SC925 Cable to connect directly to the MD9.

MD9 Multidrop Interface

2

The MD9 at the computer is connected to one or more other MD9s with coax cable terminated with BNC connectors. Refer to Appendix A for cable specifications and source references.

The MD9 at the datalogger is connected via an SC12 cable (supplied with the MD9) and is powered from the datalogger SERIAL I/O port.

Each MD9 includes a BNC "T" connector to allow for coax in/ coax out. "T" connectors on MD9s at the beginning (computer) and end (last datalogger) of the network must be terminated with 75 ohm Coax Terminators in order to prevent signal reflection from one end of the cable to the other. Place terminators on the ends of the main cable only. Any branch cables from the main cable to an MD9 should be less than 10 feet in length. No terminator is used on the T connector at the MD9 on a branch. (Figure 2-1).

There are two ground terminals located between the Serial I/O and Coax Connectors on the MD9. When installing the MD9, a 16AWG or heavier wire should be connected from earth ground to one of these terminals.

FIGURE 1-1. MD9 Multidrop Interface

NOTE

MD9 Multidrop Interface

3

FIGURE 2-1. System Description

3. Software and Datalogger Compatibility PC208 Software Index #5348-00 or higher is required for use with MD9s. Customers using older software may purchase a software update for a nominal charge by contacting Campbell Scientific.

The following dataloggers may be used in an MD9 network.

CR10 all 21X SN6195 or higher 700X Control Module SN1670 or higher

21Xs and 700Xs with lower SNs require a resistor modification which permits the respective 5 Volt power supplies to source enough current to operate an MD9. Contact Campbell Scientific customer service if your datalogger requires this modification.

4. ID and Baud Rate Selection Each MD9 in an MD9 network must have a unique ID. The ID is set by the ID select switch (Figure 4-1). This switch is located under the cover, and can be accessed by removal of the four cover screws.

Appendix C gives a complete list of ID and switch settings.

MD9 Multidrop Interface

4

TABLE 4-1. ID Settings for MD9 Connected to Computer

Software Used ID

Dos PC208 (GraphTerm, Telcom, and PC208E) 1 - 254 Windows PC208W (Tcom) 255

An MD9 with the ID set to 255 can be used with the DOS PC208 by adding a pound sign (#) to the end of the base MD9 dialing path in the PC208 station file. This is useful if PC208 and PC208W must be used on the same MD9 network.

Address 255 is also used when the MD9 is connected to a telephone modem (Section 6).

MD9s are shipped with the Baud Rate Selection Jumpers set at 9600 Baud. Other baud rates may be selected when necessary. All MD9s in a system must be set at the SAME baud rate.

9600 Baud 1200 Baud 300 Baud

A-B Short A-B Open A-B Short

C-D Short C-D Short C-D Open

FIGURE 4-1. ID Switch and Baud Rate Selection Jumpers

5. Maximum Number of Dataloggers and Coax Length

The maximum coax run that can operate reliably is dependent on the signal loss due to the type of wire selected and the load placed on the system by each MD9 and coax terminator. The total signal loss in an MD9 system cannot be greater than 50 db.

Each MD9 attenuates the signal by 0.2 db. Each 100 ft. of Belden 9100 coax cable attenuates the signal by 0.6 db. The terminator pair account for a 6 db loss. A quick calculation shows that a network of 34 dataloggers on 5,000 feet of coax is a workable system.

NOTE

NOTE

MD9 Multidrop Interface

5

35 MD9s @ 0.2 db 7 db (including MD9 at PC) 5,000 ft. @ 0.6 db/ 100 ft. 30 db Coax terminator pair 6 db

Total Signal Loss 43 db

6. Telephone to MD9 Network It is possible to access an MD9 network via telephone when the network is miles from the PC. See Figure 6-1.

A Campbell Scientific Model COM200 Telephone Modem is used in conjunction with a Model PS512M 12 and 5 Volt Charging Regulator to communicate with an MD9. The COM200 and the MD9 are both supplied with a 9 pin SC12 cable suitable for connection to the PS512M. The PS512M provides 5 volts for system operation and performs the function of a null modem (the COM200 & MD9 are both "modem" devices).

The PS512M requires a 12 Volt battery for operation and contains a charging circuit to maintain the battery voltage level. The PS512M includes an AC wall transformer for AC operation A solar panel (optional) may be used if AC is unavailable.

A PS512M with a serial number less than 1712 does not supply 12 volts to the COM200 modem. Use adapter 10704 or connect 12 volts and ground to the 12 volts and ground terminals on the COM200.

The MD9 connected to the COM200 telephone modem must have the ID switch set to 255 (all switches open). When creating the station file in PC208 the base telephone with phone number is entered first and the MD9 with ID is entered second.

When configuring the network in PC208W a modem device (9600 baud) is added to a COM port, the MD9 device attaches to the Modem, and the datalogger to the MD9. The base phone number is entered in the MD9 window and the Switch Setting of Remote MD9 (ID) is entered in the datalogger window.

In order to make measurements at the telephone to MD9 location, a datalogger with it's own MD9 is required.

NOTE

NOTE

MD9 Multidrop Interface

6

COM200

FIGURE 6-1. Telephone to MD9 Conversion

7. Operation Communication between the computer and a datalogger is initiated and controlled by the computer. The MD9 at the computer is activated when Pin 20, Data Terminal Ready (DTR), is pulled high on the computer's I/O port. The signal is passed through the SC532(A) and in turn brings Pin 5 Modem Enable (ME) high on the MD9s I/O port.

When the ME line is pulled high, the MD9 goes from State 0 standby to State 1 active. Once in State 1, any information transmitted by the computer is passed on to the coax network. This remains true until the DTR and ME line are pulled low and the MD9 reverts to State 0.

Immediately after the computer enables its MD9 it must send a "BREAK" command followed by the "ADDRESS" of the destination MD9. See the timing diagram in Appendix C.

Upon detecting activity on the coax line, remote MD9s convert from State 0 to State 2. State 2 is a sleep mode in which the MD9 begins a timing routine to determine if a BREAK has occurred. If a BREAK is not detected, the MD9 returns to State 0. If a BREAK is detected, all remote Multidrop Interfaces capture and read the ADDRESS.

The properly addressed MD9 progresses to State 3 in which it pulls the datalogger ring line and buffers any bytes of information which followed the ADDRESS. All other remote MD9s alternate between States 0 and 2 trying to identify whether the continuing activity on the network is a new BREAK.

When the datalogger detects the ring line signal it enters its telecommunication mode and pulls its ME line high causing the MD9 to enter State 1. The link is

The null modem on the PS512M has two 9-pin connectors. The SC12 cable from the COM200 is connected to either connector and the SC12 from the MD9 is connected to the other.

MD9 Multidrop Interface

7

now complete. The computer can now send several carriage returns which permits the datalogger to synchronize at the same baud rate.

Once the datalogger baud rate has been synchronized, data retrieval, data monitoring and re-programming of the datalogger can be carried out.

To terminate communications with a datalogger, use the E command (followed by a carriage return) listed in the datalogger instruction manual. The datalogger will respond by lowering the ME line to its MD9 causing it to return to State 0.

In order to activate the next datalogger station, a BREAK and the next ADDRESS is sent by the computer. This procedure continues until all dataloggers in a network have been interrogated.

When all data for a particular time period has been collected and stored by the computer, the computer's DTR line is released causing the local MD9 to return to State 0.

An MD9 used in the telephone conversion must be operated in the "Protocol Mode". In the Protocol Mode, the MD9 communicates with the computer via the phone and controls activity on the coax network generating the "Break" command, etc. The Protocol Mode is activated when the MD9 ID switch is set to 255 (all switches OPEN).

When a station file is set up using PC208 software and the MD9 is not entered as the FIRST "Interface Device", the software assumes the MD9 at the phone modem is in the Protocol Mode.

If both conditions are met the MD9 ID set to 255 and the MD9 is not the first Interface Device the telephone to MD9 conversion is transparent to the user.

MD9 Multidrop Interface

8

This is a blank page.

A-1

Appendix A. Cable Specifications and Source References

Belden 1505A:

Conductor: 20 AWG solid copper (.032 ) Jacket Material: PVC Jacket O.D.: .235 Shield: Braided tinned copper (100% coverage) Resistance: 10/1000 Capacitance: 16.2pf/ft. Impedance: 75 Ohms Attenuation at 1 MHz: 0.29 db/100

Belden Wire and Cable P.O. Box 1980 Richmond, IN 47375 317-983-5200

This is a blank page.

B-1

Appendix B. Break/Address Timing A BREAK consists of continuous spacing for time greater than 10 times the inverse of BR (baud rate). The BREAK is followed by a marking period and single byte ADDRESS. The marking time must be greater than one times the inverse of BR and the marking time and ADDRESS must be completed within 100 msec.

This is to say that a 9600 baud, the BREAK must be greater than 1.1 m sec followed by marking for 105 usec. The 8 bit single character ADDRESS (least significant bit first) is then completed within 100 msec after the end of BREAK.

FIGURE B-1. Break/Address Timing Diagram

This is a blank page.

C-1

Appendix C. Setting the Station ID Each MD9, including the one in the MD9 base station, must have a unique Station ID. Following is a list of all possible Station IDs with the corresponding setting of the dip switches. Here, 1 represents open and 0 is closed.

When a station is configured for phone to MD9, PC208 DOS software cannot recognize an MD9 address greater than 127.

SWITCHES SWITCHES SWITCHES ID 1234 5678 ID 1234 5678 ID 1234 5678

43 1101 0100 86 0110 1010 1 1000 0000 44 0011 0100 87 1110 1010 2 0100 0000 45 1011 0100 88 0001 1010 3 1100 0000 46 0111 0100 89 1001 1010 4 0010 0000 47 1111 0100 90 0101 1010 5 1010 0000 48 0000 1100 91 1101 1010 6 0110 0000 49 1000 1100 92 0011 1010 7 1110 0000 50 0100 1100 93 1011 1010 8 0001 0000 51 1100 1100 94 0111 1010 9 1001 0000 52 0010 1100 95 1111 1010

10 0101 0000 53 1010 1100 96 0000 0110 11 1101 0000 54 0110 1100 97 1000 0110 12 0011 0000 55 1110 1100 98 0100 0110 13 1011 0000 56 0001 1100 99 1100 0110 14 0111 0000 57 1001 1100 100 0010 0110 15 1111 0000 58 0101 1100 101 1010 0110 16 0000 1000 59 1101 1100 102 0110 0110 17 1000 1000 60 0011 1100 103 1110 0110 18 0100 1000 61 1011 1100 104 0001 0110 19 1100 1000 62 0111 1100 105 1001 0110 20 0010 1000 63 1111 1100 106 0101 0110 21 1010 1000 64 0000 0010 107 1101 0110 22 0110 1000 65 1000 0010 108 0011 0110 23 1110 1000 66 0100 0010 109 1011 0110 24 0001 1000 67 1100 0010 110 0111 0110 25 1001 1000 68 0010 0010 111 1111 0110 26 0101 1000 69 1010 0010 112 0000 1110 27 1101 1000 70 0110 0010 113 1000 1110 28 0011 1000 71 1110 0010 114 0100 1110 29 1011 1000 72 0001 0010 115 1100 1110 30 0111 1000 74 0101 0010 117 1010 1110 32 0000 0100 75 1101 0010 118 0110 1110 33 1000 0100 76 0011 0010 119 1110 1110 34 0100 0100 77 1011 0010 120 0001 1110 35 1100 0100 78 0111 0010 121 1001 1110 36 0010 0100 79 1111 0010 122 0101 1110 37 1010 0100 80 0000 1010 123 1101 1110 38 0110 0100 81 1000 1010 124 0011 1110 39 1110 0100 82 0100 1010 125 1011 1110

Appendix C. Setting the Station ID

C-2

SWITCHES SWITCHES SWITCHES ID 1234 5678 ID 1234 5678 ID 1234 5678

40 0001 0100 83 1100 1010 126 0111 1110 41 1001 0100 84 0010 1010 127 1111 1110 42 0101 0100 85 1010 1010 128 0000 0001

129 1000 0001 172 0011 0101 215 1110 1011 130 0100 0001 173 1011 0101 216 0001 1011 131 1100 0001 174 0111 0101 217 1001 1011 132 0010 0001 175 1111 0101 218 0101 1011 133 1010 0001 176 0000 1101 219 1101 1011 134 0110 0001 177 1000 1101 220 0011 1011 135 1110 0001 178 0100 1101 221 1011 1011 136 0001 0001 179 1100 1101 222 0111 1011 137 1001 0001 180 0010 1101 223 1111 1011 138 0101 0001 181 1010 1101 224 0000 0111 139 1101 0001 182 0110 1101 225 1000 0111 140 0011 0001 183 1110 1101 226 0100 0111 141 1011 0001 184 0001 1101 227 1100 0111 142 0111 0001 185 1001 1101 228 0010 0111 143 1111 0001 186 0101 1101 229 1010 0111 144 0000 1001 187 1101 1101 230 0110 0111 145 1000 1001 188 0011 1101 231 1110 0111 146 0100 1001 189 1011 1101 232 0001 0111 147 1100 1001 190 0111 1101 233 1001 0111 148 0010 1001 191 1111 1101 234 0101 0111 149 1010 1001 192 0000 0011 235 1101 0111 150 0110 1001 193 1000 0011 236 0011 0111 151 1110 1001 194 0100 0011 237 1011 0111 152 0001 1001 195 1100 0011 238 0111 0111 153 1001 1001 196 0010 0011 239 1111 0111 154 0101 1001 197 1010 0011 240 0000 1111 155 1101 1001 198 0110 0011 241 1000 1111 156 0011 1001 199 1110 0011 242 0100 1111 157 1011 1001 200 0001 0011 243 1100 1111 158 0111 1001 201 1001 0011 244 0010 1111 159 1111 1001 202 0101 0011 245 1010 1111 160 0000 0101 203 1101 0011 246 0110 1111 161 1000 0101 204 0011 0011 247 1110 1111 162 0100 0101 205 1011 0011 248 0001 1111 163 1100 0101 206 0111 0011 249 1001 1111 164 0010 0101 207 1111 0011 250 0101 1111 165 1010 0101 208 0000 1011 251 1101 1111 166 0110 0101 209 1000 1011 252 0011 1111 167 1110 0101 210 0100 1011 253 1011 1111 168 0001 0101 211 1100 1011 254 0111 1111 169 1001 0101 212 0010 1011 255 1111 1111 170 0101 0101 213 1010 1011 171 1101 0101 214 0110 1011

D-1

Appendix D. SC532A The SC532A differs from the SC532 in three ways:

1. Provides 12 V on PERIPHERAL Port pin 8 2. PROGRAM mode 3. Jack on SC532A POWER input

The SC532A supplies 12 VDC via PERIPHERAL connector pin 8 for the purpose of powering 12 V peripherals.

The SC532As internal jumper selects SC532 or PROG mode. For the MD9 leave the jumper in the factory default position of SC532. PROG is a special mode for satellite transmitters only.

The SC532A has a POWER jack allowing convenient replacement in the event of AC adapter failure (see CAUTION below). The jack also facilitates operating the SC532A from datalogger power at remote sites by using optional field cable (item number 14020) in place of the AC adapter. Simply plug the cables DB9 connector into the dataloggers CS I/O port for 12 V power. If you have an earlier datalogger lacking 12 V on CS I/O port pin 8 (DVM test between paper-clip inserted in pin 8 and GND) the field cable can be modified to connect to the dataloggers power terminals as follows:

1. Unplug field cable from datalogger and SC532A. 2. Cut off DB9 connector. 3. Remove cable sheath exposing positive (RED) wire and negative

(BLACK) wire 2 inches back. 4. Strip inch of insulation from each wire and tin ends. 5. Connect RED wire to datalogger 12 V and BLACK wire to datalogger

power ground terminal. The correct barrel connector polarity is (+) on the inner bore and () on the outer sleeve.

The MD9 requires that a minimum of 6 VDC @ 90 mA be supplied to the SC532A POWER jack from AC adapter or field cable. The maximum voltage that can be safely applied to the SC532A POWER jack is 17 VDC.

Before plugging the power connector into the SC532A, if you have 1) cut off optional field cables DB9, 2) replaced the factory AC adapter, or 3) built your own dc power cable, make sure that the voltage polarity is correct on the barrel connector. Application of REVERSED POLARITY power to the SC532A can damage the SC532A, datalogger, and peripheral (not covered under warranty)!

Barrel connector inner bore (+)

Barrel connector outer sleeve ()

The maximum POWER input voltage is 17 VDC!

CAUTION

This is a blank page.

This is a blank page.

Campbell Scientific Companies

Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES

www.campbellsci.com info@campbellsci.com

Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450

Somerset West 7129 SOUTH AFRICA

www.csafrica.co.za sales@csafrica.co.za

Campbell Scientific Australia Pty. Ltd. (CSA) PO Box 444

Thuringowa Central QLD 4812 AUSTRALIA www.campbellsci.com.au info@campbellsci.com.au

Campbell Scientific do Brazil Ltda. (CSB) Rua Luisa Crapsi Orsi, 15 Butant

CEP: 005543-000 So Paulo SP BRAZIL www.campbellsci.com.br

suporte@campbellsci.com.br

Campbell Scientific Canada Corp. (CSC) 11564 - 149th Street NW

Edmonton, Alberta T5M 1W7 CANADA

www.campbellsci.ca dataloggers@campbellsci.ca

Campbell Scientific Ltd. (CSL) Campbell Park

80 Hathern Road Shepshed, Loughborough LE12 9GX

UNITED KINGDOM www.campbellsci.co.uk sales@campbellsci.co.uk

Campbell Scientific

Manualsnet FAQs

If you want to find out how the MD9 Campbell Scientific works, you can view and download the Campbell Scientific MD9 Interface Instruction Manual on the Manualsnet website.

Yes, we have the Instruction Manual for Campbell Scientific MD9 as well as other Campbell Scientific manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instruction Manual should include all the details that are needed to use a Campbell Scientific MD9. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Campbell Scientific MD9 Interface Instruction Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Campbell Scientific MD9 Interface Instruction Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Campbell Scientific MD9 Interface Instruction Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Campbell Scientific MD9 Interface Instruction Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Campbell Scientific MD9 Interface Instruction Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.