Contents

Campbell Scientific LoggerNet Android App Instruction Manual PDF

1 of 35
1 of 35

Summary of Content for Campbell Scientific LoggerNet Android App Instruction Manual PDF

C o p y r i g h t 2 0 1 6 - 2 0 1 7 C a m p b e l l S c i e n t i f i c , I n c .

LoggerNet Mobile Connect

for Android Revision: 8/17

i

Table of Contents Introduction ..................................................................................... 2

Requirements ................................................................................... 2

Getting Started ................................................................................ 2

Connecting .................................................................................... 5

Connected ...................................................................................... 5

Disconnecting ................................................................................ 6

Connecting ...................................................................................... 6

Numeric Display ............................................................................. 6

Status ............................................................................................... 9

Historic .......................................................................................... 15

Custom Collect .............................................................................. 19

Files ............................................................................................... 22

Disconnect ..................................................................................... 25

Offline Files .................................................................................. 26

LoggerNet Mobile Connect Settings ............................................. 26

End User License Agreement (EULA) for Mobile Applications . 28

2

Introduction Please read the End User License Agreement (EULA).

LoggerNet Mobile Connect is a simple, yet powerful, tool that allows communication with any station in your LoggerNet network. It gives you access to the LoggerNet server anywhere your mobile device has a data connection. The app lets you perform field maintenance tasks such as viewing and collecting data, changing the value of variables, checking important status information about LoggerNet and the health of your stations, setting datalogger clocks, and sending datalogger programs.

Requirements LoggerNet Mobile Connect for Android runs on Android 4.1 or greater.

To use LoggerNet Mobile Connect, a licensed copy of LoggerNet version 4.4 or later or LoggerNet Admin version 4.0 or later needs to be running on a PC that is accessible via TCP/IP.

Getting Started When LoggerNet Mobile Connect is launched, you begin by tapping the button in the upper right corner of the screen.

Your Android device must be connected to a network through which you can reach your LoggerNet server, LoggerNet must be

TOC

3

running, and your LoggerNet server must have remote connections enabled.

On the Log into Server screen, type in the IP Address (or domain name) of the computer running LoggerNet. Enter the port used by LoggerNet for TCP/IP communications (default value is 6789). If LoggerNet security is enabled, enter the Username and Password to be used to log in to the LoggerNet server. After filling in the values, press OK. LoggerNet Mobile Connect will connect to your LoggerNet server, and the dataloggers in your network map will be displayed. If you have subnets set up in LoggerNet Admin, All Stations or the name of the current subnet will be shown at the top of datalogger list. You can tap the arrow to the right to select a different subnet or all stations.

TOC

4

The time of last collection from each datalogger will be displayed. The color of text used for the time of collection indicates the collection state. The text will be black when

TOC

5

collection state is normal. If the schedule is turned off, the text will be blue. All other states will be reflected by red. Tapping the i button next to a datalogger displays additional information about the collection state and provides a Collect Now button to trigger data collection. Collected data will be stored to the location specified in the LoggerNet servers Setup screen.

Note: Stations set up in the RWIS Administrator are not supported in LoggerNet Mobile Connect and will not show up in the list of stations.

Connecting To connect to a datalogger, simply tap on it in the list of dataloggers.

Connected After you have connected with your datalogger, a set of tabs will appear at the bottom of the screen. Tapping on these tabs will allow you to perform different operations on your datalogger such as viewing data in a tabular or graphical format, monitoring status, and collecting data.

If you leave LoggerNet Mobile Connect or your device goes to sleep while connected to a datalogger, you will be automatically disconnected from the datalogger 10 minutes after any background processes (such as data collection) complete. Note that if you have Prevent Sleep enabled (see the LoggerNet

TOC

6

Mobile Connect Settings section) your device will not automatically go to sleep while you are connected to a datalogger. You must put the device to sleep manually or disconnect from the datalogger.

Disconnecting When you are finished interacting with your datalogger, tap your devicess Menu button and select Disconnect (or simply tap your devices Back button) to disconnect and return to the list of dataloggers.

Connecting To connect to a datalogger, simply tap on the datalogger in your LoggerNet network map. When connecting to a datalogger, a clock check is sent to see if communications can be established.

Numeric Display The Numeric Display page displays the current data record for the selected table.

TOC

7

Tap the icon in the upper right corner to select and configure a different table.

TOC

8

Values are formatted based on type and, by default, include the units defined in the datalogger program.

Touch and hold a settable value to open a page that allows you to change the value.

Numeric Display Setup

Selected Table Select the table that will be displayed.

Select Fields Select the fields that will be displayed.

Polling Interval Select the interval at which the data will be updated. The LoggerNet Mobile Connect App will never poll faster than 1 time per second.

Show Units Use the check box to specify whether or not units are displayed.

Field Options Each field may be edited. Tap the button to the right of the field name. This will display customization options for that particular field. These options include:

Title The name that will be displayed for the field.

Units The measurement units that will be displayed for the field.

TOC

9

Precision The number of digits of precision used. (Only displayed if the field value is floating point type.)

Status The Status page shows important information about your datalogger, the current program, the errors, the card status, the battery, and the clock. It also allows you to send a program to your datalogger.

TOC

10

Note: Not all status fields listed below apply to array-based dataloggers (i.e., CR10X, CR510, CR23X, etc.).

TOC

11

Program Info

Current The program currently running in the datalogger.

Start Time The date the currently running program was started.

Run Signature Signature of the compiled binary data structure for the current program. This value is independent of comments added or non-functional changes to the program. Often changes with operating system changes.

Program Signature Signature of the currently running program file including comments. Does not change with operating system changes.

Compile Results The results reported by the datalogger when it compiled the currently running program.

Send Program Click to send a new program file to the datalogger. The program file must be accessible to the LoggerNet Mobile Connect App. (Programs to be sent to your datalogger must be stored on your device in the Campbellsci/LNMobile folder or a subfolder of that folder. With your device connected to a computer as a disk drive, you can navigate to this folder to copy files to your device from the computer.) When Send Program is clicked, a browser window is displayed allowing you to browse to the desired program file. When a file is selected, it will be sent, compiled, and

TOC

12

assigned the Run Options of Run Now and Run on Power- up.

Datalogger Info

Station Name A name assigned to this datalogger. Note that this is the station name internal to the datalogger. It is not the name given to the datalogger in LoggerNet.

Model The type of datalogger.

OS Version Specifies the version of the operating system currently in the datalogger.

OS Date The date of the current operating system.

OS Signature The signature of the current operating system.

Panel Temperature Current panel temperature measurement. This measurement is made in the background calibration.

Memory Free The amount of unallocated memory on the CPU (SRAM). All free memory may not be available for data tables. As memory is allocated and freed, holes of unallocated memory, which are unusable for final storage, may be created.

TOC

13

Memory The total amount of SRAM in the datalogger.

Serial Number Specifies the datalogger serial number assigned by the factory when the datalogger was calibrated.

Errors

Watchdog Errors The number of internal watchdog errors that have occurred while running the current program.

Skipped Records The number of records that have been skipped for a given table. Skipped records are normally caused by skipped scans.

Low 12V Count The number of occurrences of the 12VLow signal being asserted. When this condition is detected, the datalogger ceases measurements and goes into a low power mode until proper system voltage is restored.

Low 5V Count The number of occurrences of the 5VExtLow signal being asserted.

Skipped Scans The number of skipped scans that have occurred while running the current program. Does not include scans intentionally skipped as may occur with the use of ExitScan and Do...Loop instructions.

TOC

14

Skipped System Scans The number of scans skipped in the background calibration.

Skipped Slow Scans The number of scans skipped in a SlowSequence.

Variable Out of Bounds The number of times an array was accessed out of bounds.

Battery Info

Battery Voltage The current value of the battery voltage. This measurement is made in the background calibration.

Lithium Battery The current voltage of the lithium battery. This measurement is updated in background calibration.

Card Info

Card Status Reports the status of the CF card.

Bytes Free The amount of space still available on the CF card.

Clock Info

System The local time of your device the last time the datalogger clock was checked.

TOC

15

Logger The time reported by the datalogger the last time its clock was checked.

Set Clock Click to set the datalogger clock. You can choose to either manually set the datalogger clock or to set the datalogger clock to your devices clock. An attempt will be made to set the clock as closely as possible to the desired time, but there may be some difference due to delay in the communication link. This option should be used with caution, since it could result in missing or duplicate timestamps when the datalogger clock is changed.

Historic The Historic page displays data from a single datalogger table in graph or tabular form.

TOC

16

The data displayed on the Historic page comes directly from the datalogger and is cloned on the PC running LoggerNet. It does

TOC

17

not affect the data displays or data collection occurring in LoggerNet.

From the main Historic screen, tap Graph or Table at the top to choose how to display your data.

Tap the icon in the upper right corner to go to Historic Setup. This allows you to select the table and fields to be displayed. An option for showing the legend is also available. You can tap Data Range to change the data range that will be displayed. (The default data range is one hour.) You can tap Polling Interval to specify how often the datalogger is polled for new data. (The default Polling Interval for a data table is the table interval, or one second if the table interval is less than one second. The default Polling Interval for the Public, Status, and DataTableInfo tables is one second. The minimum Polling Interval for any table is one second.) Once fields have been selected, you can tap on the name of a field to set the display options for that field as described below. After completing the setup, tap Save to display your selected data.

On a graph, tap a point on the graph to display the data value and timestamp at that point. You can zoom in on a part of the graph by touching the screen with two fingers and then sliding your fingers apart. You can zoom out by pinching your fingers together. You can pan the graph by using one finger to drag the graph to the desired location. A zoomed or panned graph can be restored by selecting the Restore icon at the top.

TOC

18

On the table, the current data will be displayed in tabular format. You may sort the data by time simply by tapping the Time column heading.

Historic Setup

Select Table/Fields Select the table and fields that will be displayed in the graph and table.

Show Legend Determines whether a legend is shown on the graph.

Data Range The range of data to be displayed in the graph and table.

Polling Interval The interval at which the datalogger is polled for new data.

Field Options

Field Title The title used in the graph legend and the table column heading.

Graph Axis Each series can be displayed using the left or right axis of the graph.

Graph Line Width The width of the line used for the graph series.

Graph Line Color The color of the line used for the graph series.

TOC

19

Graph Line Style The style of the line used for the graph series.

Graph Symbol Size The size of the symbol used for the graph series.

Graph Symbol Color The color of the symbol used for the graph series.

Graph Symbol Style The style of the symbol used for the graph series.

Custom Collect The Custom Collect page is used to download data from your datalogger and store it in data files on your device. These data files can then be viewed, emailed from your device, or opened in another application.

TOC

20

Collected data files are stored on your device in the Campbellsci/LNMobile/server_IP_address/datalogger_name directory where server_IP_address is the IP address (or domain

TOC

21

name) of the LoggerNet server and datalogger_name is the name of the datalogger in the LoggerNet network map. With your device connected to a computer as a disk drive, you can navigate to this directory to copy your data files to the computer.

Note: Custom Collect is not supported for array-based dataloggers (i.e., CR10X, CR510, CR23X, etc.).

Collect Mode

The Collect Mode allows you to control how data is collected to your device.

All Data: Collect all data and overwrite existing data files on your device.

New Data: Collect data logged since your last data collection and append new data to existing data files.

Most Recent: o Records: Allows you to specify how many of the

most recent records you would like to collect. o Time: Allows you to specify a time interval from the

current time from which to collect records. o Append to End of File(s)/Overwrite Existing File(s):

Gives you the option to append to existing data files or overwrite existing data files.

Datalogger Tables

A list of all the datalogger tables that can be selected for data collection. Select the table(s) you wish to collect and tap the

TOC

22

Collect button. You can view collected data files by tapping the Eye icon next to the table name. While viewing a data file, tap the Information icon at the top to get information about the datalogger that generated the data, the datalogger program, and the data fields. Tap the Historic icon at the top to graph your data. You will be asked to select the fields and data range to graph. Tap the Share icon at the top to share the file through email or a file-sharing application such as DropBox. Tap your devices Menu button and then select Delete File to delete the data file.

Files The Files page is used to view the drives on your datalogger as well as pause/resume the currently running program. You can also view and edit files on your datalogger, send files to your datalogger, get files from your datalogger, or set the run options for a program file on your datalogger.

Note: The Files page is not supported for array-based dataloggers (i.e., CR10X, CR510, CR23X, etc.).

Current Program

Resume The Resume button restarts the paused program while preserving data files.

TOC

23

Pause The Pause button pauses the currently running program and preserves data files.

Drives

The drives on the datalogger. Selecting one of the drives displays a list of all the files on the drive.

File List

You can refresh the list of all drives and files from the datalogger by tapping the icon in the upper right corner.

Other functions are available by tapping your devices Menu button. (If your device does not have a Menu button, the functions can be accessed by using the Menu button in the upper right corner.) If no files are selected, you have the option to format the drive or send files to the datalogger from your device. If you have selected files, you can delete the selected files from the datalogger or get the selected files from the datalogger and save them to your device. If only a single file is selected, you also have the option to view the selected file. If only a single program file is selected, you also have the option to set the files run options.

Format Drive Formatting an individual drive on the datalogger will permanently delete all the files on that drive.

TOC

24

Send File(s) Files can be sent from your device to the datalogger. The file(s) must be accessible to the LoggerNet Mobile Connect App. (Files to be sent to your datalogger must be stored on your device in the Campbellsci/LNMobile folder or a subfolder of that folder. With your device connected to a computer as a disk drive, you can navigate to this folder to copy files to your device from the computer.) When Send Files is selected, a browser window is displayed allowing you to browse to the desired file(s).

Delete File(s) After selecting files from the datalogger file list, you can delete the files from the datalogger.

Get File(s) After selecting files from the datalogger file list, you can get the files from the datalogger and store them on your device. Retrieved files are stored on your device in the Campbellsci/LNMobile/server_IP_address/datalogger_ name directory where server_IP_address is the IP address (or domain name) of the LoggerNet server and datalogger_name is the name of the datalogger in the LoggerNet network map. With your device connected to a computer as a disk drive, you can navigate to this directory to copy data files to the computer.

TOC

25

View File After selecting a file from the datalogger file list, you can view the file. While viewing a file, you can make edits. You can then tap the Disk icon on the upper right to save the file to your device or to the datalogger. This allows you to edit a program on your datalogger. Note that if you edit the running program and save it to your datalogger, it will cause the program to be recompiled. While viewing a file, you can also tap the Share icon on the upper right to share the file. This will show a list of installed applications that are registered to handle the current file type. This can be used to email the file, or, if you have a file-sharing application, such as Dropbox, this option can be used to get the file to your computer.

Run Options When Run Now is selected, the program will be compiled and run in the datalogger. You may also choose to preserve existing data tables on the datalogger, if there are no changes to the table structure of the new program. Run On Power-up will set this program file to run when the datalogger loses power and then powers back up.

Disconnect When you are finished interacting with your datalogger, tap your devicess Menu button and select Disconnect (or simply tap your devices Back button) to disconnect. Disconnecting from a

TOC

26

datalogger will end the communication session and will return you to the LoggerNet network map.

Offline Files Pressing the Menu button and selecting Manage Files (i.e., when you are not connected to a datalogger) will display the files on your device that are associated with LoggerNet Mobile Connect. Tapping a server and then the device sub-folder will display the files downloaded from that device.

Clicking the Eye icon next to a file allows you to view that file. While viewing a program file, you can edit the file and then tap the Disk icon in the upper right corner to save the file to your device. While viewing a data file, tap the Historic icon at the top to graph your data or the Share icon at the top to share the file through email or a file-sharing application such as DropBox.

Pressing your devices Menu button with file(s) selected in a list of files allows you to delete the file(s) or share the file(s) through email or a file-sharing application such as DropBox. If only one file is selected, you also have the option to rename the file or view the file

LoggerNet Mobile Connect Settings The following settings for the LoggerNet Mobile Connect App can be viewed and/or set by tapping your devices Menu button from the main LoggerNet Mobile Connect screen (i.e., when you are not connected to a datalogger) and selecting Settings.

TOC

27

Settings: Prevent Sleep The Prevent Sleep setting will prevent your device from going to sleep when connected to a datalogger.

About LoggerNet Mobile Connect: Version The version of LoggerNet Mobile Connect.

About LoggerNet Mobile Connect: Legal The copyright for LoggerNet Mobile Connect.

TOC

28

End User License Agreement (EULA) for Mobile Applications

NOTICE OF AGREEMENT: Please carefully read this EULA. By installing or using this software, You are agreeing to comply with the following terms and conditions. If you do not want to be bound by this EULA, You must promptly remove the Licensed Application and any versions thereof from your mobile device.

By accepting this agreement, you acknowledge that this agreement is concluded between You and Campbell Scientific, Inc. only, and no other third parties. As such, Campbell Scientific, Inc. is solely responsible for the Licensed Application and the content thereof, and reserves all rights not expressly granted to You.

DEFINITIONS: Licensed Application The mobile application developed by Campbell Scientific, Inc., that is subject to this EULA.

Mobile Device Any smart phone, tablet or other device defined as a supported device in Campbell Scientific, Inc.s product literature, website, or Application Store presence.

Application Store The Application Store refers to the Apple Store, Google Play, or other distribution channel for the Licensed Application.

TOC

29

LICENSE FOR USE: The Licensed Application is licensed, not sold, to you for use under the following terms and conditions:

Scope: This license is limited to a non-transferable license to use the Licensed Application on any supported mobile device that You own or control. This license does not allow You to use the Licensed Application on any device that You do not own or control, and You may not distribute or make the Licensed Application available over a network where it could be used by multiple devices at the same time. You may not rent, lease, lend, sell, redistribute or sublicense the Licensed Application. You may not copy, decompile, reverse engineer, disassemble, attempt to derive the source code of, modify, or create derivative works of the Licensed Application, any updates, or any part thereof (except as and only to the extent any foregoing restriction is prohibited by applicable law). Any attempt to do so is a violation of the rights of Campbell Scientific, Inc. If You breach this restriction, You may be subject to prosecution and damages. The terms of this license will govern any upgrades provided by Campbell Scientific, Inc. that replace and/or supplement the original Licensed Application, unless such upgrade is accompanied by a separate license in which case the terms of that license will govern.

Consent to Use of Data: You agree that Campbell Scientific, Inc. may collect and use technical data and related information that is provided by the Application Store, including but not limited to technical information about Your device, system and application

TOC

30

software, and peripherals, that is gathered periodically to facilitate the provision of software updates, product support and other services to You (if any) related to the Licensed Application. Campbell Scientific, Inc. may use this information, as long as it is in a form that does not personally identify You, to improve its products or to provide services or technologies to You.

MAINTENANCE AND SUPPORT: Campbell Scientific or its Companies are responsible for any maintenance and support services with respect to the Licensed Application as required by law. No other third party, including Apple or Google, has any obligation to furnish maintenance and support services with respect to the Licensed Application.

Requests for maintenance, support, or other inquiries should be addressed to Campbell Scientific, Inc. or a Campbell Scientific company covering your region, as noted in CAMPBELL SCIENTIFIC COMPANIES below.

WARRANTIES: Campbell Scientific, Inc. is solely responsible for addressing any claims You may have relating to the use of the Licensed Application. The following warranties are in effect for thirty (30) days from the date of original purchase. These warranties are not extended by the installation of upgrades.

Campbell Scientific warrants that the software itself will perform substantially in accordance with the specifications set forth in the user manual when properly installed and used in a

TOC

31

manner consistent with the published recommendations, including recommended system requirements. CSI disclaims all other warranties including those implied at law. Campbell Scientific does not warrant that the software will meet Your requirements for use, or that the software or documentation are error free, or that the operation of the software will be uninterrupted. You expressly acknowledge and agree that use of the Licensed Application is at Your sole risk and that the entire risk as to satisfactory quality, performance, accuracy and effort is with You.

This warranty does not cover any software that has been altered or changed in any way by anyone other than Campbell Scientific. Campbell Scientific is not responsible for problems caused by computer or mobile device hardware, computer or mobile device operating systems, or the use of Campbell Scientifics software with non-Campbell Scientific software or hardware.

LIMITATION OF LIABILITIES: All warranties of merchantability and fitness for a particular purpose are disclaimed and excluded. Your sole and exclusive remedy is set forth in this limited warranty. In no event shall Campbell Scientific, Inc. be liable for personal injury, or any incidental, special, indirect or consequential damages whatsoever, including, without limitation, damages for loss of profits, loss of data, business interruption or any other commercial damages or losses, arising out of or related to your use or inability to use the

TOC

32

Licensed Application, however caused, regardless of the theory of liability (contract, tort or otherwise) and even if Campbell Scientific, Inc. has been advised of the possibility of such damages. Campbell Scientifics aggregate liability arising from or relating to this agreement or the software or documentation is limited to the purchase price paid by You.

INTELLECTUAL PROPERTY RIGHTS: In the event of any third party claim that the Licensed Application or Your possession and use of that Licensed Application infringes that third partys intellectual property rights, Campbell Scientific, Inc. will be solely responsible for the investigation, defense, settlement and discharge of any such intellectual property infringement claim.

LEGAL COMPLIANCE: By accepting this agreement, You represent and warrant that You (i) are not located in a country that is subject to a U.S. Government embargo, or that has been designated by the U.S. Government as a terrorist supporting country; and (ii) are not listed on any U.S. Government list of prohibited or restricted parties.

COPYRIGHT: This software is protected by United States copyright law and international copyright treaty provisions. This software may not be sold, included or redistributed in any other software, or altered in any way without prior written permission from Campbell Scientific. All copyright notices and labeling must be left intact.

TOC

33

TERMINATION: This license is effective until terminated by You or by Campbell Scientific, Inc. Your rights under this license will terminate automatically with or without notice from Campbell Scientific, Inc. if You fail to comply with any term(s) of this license or this EULA. Upon termination of the license, You shall cease all use of the Licensed Application, and destroy all copies, full or partial, of the Licensed Application.

TOC

Campbell Scientific Companies

Campbell Scientific, Inc. 815 West 1800 North Logan, Utah 84321 UNITED STATES

www.campbellsci.com info@campbellsci.com

Campbell Scientific Africa Pty. Ltd. PO Box 2450

Somerset West 7129 SOUTH AFRICA

www.campbellsci.co.za cleroux@csafrica.co.za

Campbell Scientific Southeast Asia Co., Ltd. 877/22 Nirvana@Work, Rama 9 Road

Suan Luang Subdistrict, Suan Luang District Bangkok 10250

THAILAND www.campbellsci.asia info@campbellsci.asia

Campbell Scientific Australia Pty. Ltd. PO Box 8108

Garbutt Post Shop QLD 4814 AUSTRALIA

www.campbellsci.com.au info@campbellsci.com.au

Campbell Scientific (Beijing) Co., Ltd. 8B16, Floor 8 Tower B, Hanwei Plaza

7 Guanghua Road Chaoyang, Beijing 100004

P.R. CHINA www.campbellsci.com info@campbellsci.com.cn

Campbell Scientific do Brasil Ltda. Rua Apinags, nbr. 2018 Perdizes CEP: 01258-00 So Paulo SP

BRASIL www.campbellsci.com.br vendas@campbellsci.com.br

Campbell Scientific Canada Corp. 14532 131 Avenue NW Edmonton AB T5L 4X4

CANADA www.campbellsci.ca dataloggers@campbellsci.ca

Campbell Scientific Centro Caribe S.A. 300 N Cementerio, Edificio Breller

Santo Domingo, Heredia 40305 COSTA RICA

www.campbellsci.cc info@campbellsci.cc

Campbell Scientific Ltd. Campbell Park

80 Hathern Road Shepshed, Loughborough LE12 9GX

UNITED KINGDOM www.campbellsci.co.uk sales@campbellsci.co.uk

Campbell Scientific Ltd. 3 Avenue de la Division Leclerc

92160 ANTONY FRANCE

www.campbellsci.fr info@campbellsci.fr

Campbell Scientific Ltd.

Manualsnet FAQs

If you want to find out how the LoggerNet Campbell Scientific works, you can view and download the Campbell Scientific LoggerNet Android App Instruction Manual on the Manualsnet website.

Yes, we have the Instruction Manual for Campbell Scientific LoggerNet as well as other Campbell Scientific manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Instruction Manual should include all the details that are needed to use a Campbell Scientific LoggerNet. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Campbell Scientific LoggerNet Android App Instruction Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Campbell Scientific LoggerNet Android App Instruction Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Campbell Scientific LoggerNet Android App Instruction Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Campbell Scientific LoggerNet Android App Instruction Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Campbell Scientific LoggerNet Android App Instruction Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.