Fig. 1 Unit 707E

Our products are designed, tested and built in accordance with DOE standardized procedures; however, actual operating results and efficiencies may vary based on manufacturing and supplier tolerances, equipment configuration, operating conditions and installation practices.

707E Preferred 15 and 16 SEER 2-Stage Packaged Air Conditioner System with Puron (R-410A) Refrigerant Single and Three Phase 2-5 Nominal Tons (Sizes 24-60)

Technician Name

Phone Number

Address

Company Name

Date Installed

NOTE TO EQUIPMENT OWNER:

For your convience, please record the model and serial numbers of your new equipment in the spaces

provided. This information, along with the installation data and dealer contact information, will be

helpful should your system require maintenance or service.

UNIT INFORMATION

ACCESSORIES (List type of model #)

INSTALLATION INFORMATION

DEALERSHIP CONTACT INFORMATION

This manual must be left with the eqipment owner.

NOTE TO INSTALLER:

Model #

Serial #

707E: Owners Information Manual

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 2

Safety Considerations Improper installation adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product Refer to the individual instructions packaged with the kits or accessories when installing. Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use quenching cloth for brazing operations. Have a fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit. Consult local building codes, the current editions of the National Electrical Code (NEC) NFPA 70. In Canada refer to the current editions of the Canadian electrical Code CSA C22.1.

Recognize safety information. This is the safety-alert symbol . When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand these signal words; DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation. NOTE: Installer: This manual should be left with the equipment user.

Starting or Shutting Unit Off To start the unit: 1. Turn on the electrical power supply to unit. 2. Select temperature and set MODE control to desired mode.

To shut unit off: NOTE: If the unit is being shut down because of a malfunction, call your dealer as soon as possible. 1. Set system MODE control to OFF. 2. Turn off the electrical power supply to unit.

Operating Your Unit The operation of your unit is controlled by indoor thermostat. You simply adjust the thermostat and it maintains the indoor temperature at the level you select. Most thermostats of cooling systems have 3 controls: a temperature control selector, a FAN control, and a SYSTEM or MODE control. Refer to your thermostat owners manual for more information. To better protect your investment and to eliminate unnecessary service calls, familiarize yourself with the following facts: Cooling Mode With the SYSTEM or MODE control set to COOL, your unit will run in cooling mode until the indoor temperature is lowered to the level you have selected. On extremely hot days, your unit will run for longer periods at a time and have shorter off periods than on moderate days. Heating Mode (if installed with optional electric heat) Your system may also be equipped with an electric heating source. On cold days and nights, place your MODE control to HEAT and your system will automatically turn on the supplemental heat in order to maintain the level of comfort you have selected.

Maintenance and Service This section discusses maintenance that should be performed on your system. Most maintenance should be performed by your dealer. You, as the owner, may wish to handle some minor maintenance for your new unit. Routine Maintenance All routine maintenance should be handled by skilled, experienced personnel. Your dealer can help you establish a standard procedure.

WARNING! FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury, death, and/or property damage. Installation and servicing of this equipment can be hazardous due to mechanical and electrical components. Only trained and qualified personnel should install, repair, or service this equipment.

WARNING! FIRE, EXPLOSION HAZARD Failure to follow this warning could result in personal injury, death, and/or property damage. Do not store or use combustible materials, gasoline, or other flammable vapors and liquids in the vicinity of this or any other appliance.

WARNING! ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury and/or death. Before performing recommended maintenance, be sure the main power switch to unit is turned off and lock-out tag is installed.

CAUTION! CUT HAZARD Failure to follow this caution may result in personal injury. When removing access panels or performing maintenance functions inside your unit, be aware of sharp sheet metal parts and screws. Although special care is taken to reduce sharp edges to a minimum, be extremely careful and wear appropriate protective clothing, safety glasses and gloves when handling parts or reaching into the unit.

WARNING! FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury, death or property damage. Do not use this unit if any part has been under water. Immediately call a qualified service technician to inspect the unit and to replace any part of the control system which has been under water.

707E: Owners Information Manual

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3

To assure proper functioning of the unit, flow of condenser air must not be obstructed from reaching the unit. Clearance from the top of the unit is 48 in. (1219 mm). Clearance of at least 36 in.(914 mm) is required on sides except the power entry side (42 in. [1067 mm] clearance) and the duct side (12 in. [305 mm] minimum clearance). Maintenance and Care for the Equipment Owner Before proceeding with those things you might want to maintain yourself, please carefully consider the following:

Air Filters The air filter(s) should be checked every 3 or 4 weeks and changed or cleaned whenever it becomes dirty. Dirty filters produce excessive stress on the blower motor and can cause the motor to overheat and shut down. This unit must have air filters in place before it can be operated. These filters can be located in one of at least two places. In many applications, the installer will provide return air filter grilles mounted on the wall or ceiling of the conditioned structure. In the instance of filter grilles, the filters can simply be removed from the grille and replaced. The other typical application is an accessory filter rack installed inside the unit itself. The following information is given to assist in changing filters used in these internal filter racks. Table 1 indicates the correct indoor filter size for your unit. Refer to Fig. 2 to access filters installed in the accessory filter rack. If using an Accessory Filter Rack, refer to the Installation Instructions provided with it for correct filter sizes and quantities.

Table 1 Indoor Air Filter Data

To replace or inspect filters in accessory filter rack (See Fig. 2): 1. Remove the filter access panel using a 5/16-in. nut driver. 2. Remove the filter(s) by pulling it out of the unit. If the filter(s) is

dirty, clean or replace with a new one. When installing the new filter(s), note the direction of the airflow arrows on the filter frame, which should be pointed at the indoor coil. 3. Reinstall filter access panel ensuring opening is air and water tight.

If you have difficulty locating your air filter(s) or have questions concerning proper filter maintenance, contact your dealer for instructions. When replacing filters, always use the same size and type of filter that was supplied originally by the installer.

A09044 Fig. 2 Unit Access Panel

Fans and Fan Motors Periodically check the condition of fan wheels and housings and fan-motor shaft bearings. Contact your dealer for the required annual maintenance. Indoor and Outdoor Coils Cleaning of the coils should only be done by qualified service personnel. Contact your dealer for the required annual maintenance. Condensate Drain The drain pan and condensate drain line should be checked and cleaned at the same time the cooling coils are checked by your dealer. Compressor All compressors are factory shipped with a normal charge of the correct type of refrigeration grade oil. Condenser Fan

The fan must be kept free of all obstructions to ensure proper cooling. Contact your dealer for any required service. Electrical Controls and Wiring Electrical controls are difficult to check without proper instrumentation. If there are any discrepancies in the operating cycle, contact your local dealer and request service. Refrigerant Circuit The refrigerant circuit is difficult to check for leaks without the proper equipment. If inadequate cooling is suspected, contact your local dealer for service.

WARNING! FIRE, EXPLOSION, ELECTRICAL SHOCK AND CUT HAZARD Failure to follow this warning could result in personal injury, death or property damage.

1. TURN OFF ELECTRICAL POWER TO YOUR UNIT BEFORE SERVICING OR PERFORMING MAINTENANCE. Lock out and tag switch with a suitable warning label.

2. When removing access panels or performing maintenance functions inside your unit, be aware of sharp sheet metal parts and screws. Although special care is taken to reduce sharp edges to a minimum, be extremely careful when handling parts or reaching into the unit. Wear safety glasses, glove, and appropriate protective clothing.

Unit Size Filter Size in. (mm)

24 20x20x1 (508x508x25)

30 20x24x1 (508x610x25)

36-42 24x30x1 (610x762x25)

48-60 24x36x1 (610x914x25)

CAUTION! UNIT OPERATION HAZARD Failure to follow this caution may result in property damage. Never operate your unit without filters in place. An accumulation of dust and lint on internal parts of your unit can cause loss of efficiency and blower motor and/or compressor damage.

WARNING! PERSONAL INJURY AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury, death or property damage. Do not poke sticks, screwdrivers, or any other object into revolving fan blades.

Access Panels

Filter Access Panel For Accessory Filter Rack

707E: Owners Information Manual

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 4

Unit Panels After performing any maintenance or service on the unit, be sure all panels are fastened securely in place to prevent rain from entering unit cabinet and to prevent disruption of the correct unit airflow pattern. Regular Dealer Maintenance (Also see Table 2) In addition to the type of routine maintenance you might be willing to perform, your unit should be inspected regularly by a properly trained service technician. An inspection (preferably each year) should include the following: 1. Inspection and, if required, cleaning of the outdoor and indoor

coils. 2. Inspection and, if required, cleaning of the indoor coil drain pan. 3. Inspection and cleaning of blower wheel housing and motor. 4. Inspection of all supply-air and return-air ducts for leaks,

obstructions, and insulation integrity. Any problems found should be resolved at this time.

5. Inspection of the unit base to ensure that no cracks, gaps, etc., exist which may cause a hazardous condition.

6. Inspection of the unit casing for signs of deterioration. 7. Inspection of all electrical wiring and components to assure proper

connection. 8. Inspection for leaks in the refrigerant circuit. Pressure check to

determine appropriate refrigerant charge. 9. Operational check of the unit to determine working conditions.

Repair or adjustment should be made at this time. Your servicing dealer may offer an economical service contract that covers seasonal inspections. Ask for further details. Complete service instructions can be found in the unit Installation, Start-up and Service Instructions.

Warranty Certificate Your unit has a limited warranty. Be sure to read the warranty carefully to determine the coverage for your unit. Before you call for service... ...check for several easily-solved problems. If insufficient heating or cooling is suspected: ( ) Check for sufficient airflow. Check the air filter for dirt. Check for blocked return-air or supply-air grilles. Be sure they are open and unobstructed. If these checks do not reveal the cause, call your servicing dealer. If your unit is not operating at all, check the following list for easy solutions: ( ) Check to be sure that the temperature specified by your User Interface is set below the indoor temperature during the cooling season or above the indoor temperature during heating season. Be sure the User Interface is set to COOL or HEAT and not OFF. ( ) If your unit still fails to operate, call your servicing dealer for troubleshooting and repairs. Specify the model and serial numbers of your unit. (Record them in this manual in the space provided.) If the dealer knows exactly which unit you have, he may be able to offer suggestions over the phone, or save valuable time through knowledgeable preparation for the service call. In Case of Trouble If you perform the steps above and unit performance is still unsatisfactory, shut off the unit and call your dealer.

WARNING! EXPLOSION, BURN AND ENVIRONMENTAL HAZARD Failure to follow this warning could result in personal injury, death or property damage. System under pressure. Relieve pressure and recover all refrigerant before system repair or final unit disposal. Use all service ports and open all flow-control devices, including solenoid valves.

707E: Owners Information Manual

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 5

Table 2 Maintenance Checklist Monthly maintenance items and outdoor unit rinsing may be performed by the consumer. All other maintenance items and all service work must be performed by a qualified service technician. Read all Warning labels.

Description of Maintenance Recommended Interval Consumer specific: Monthly Annual Inspect, clean, or replace air filter if filter is located indoors in return air duct. X Clear away debris and vegetation near unit. X Dealer specific: Inspect cabinet and basepan for damage. Replace panels, gaskets, and other components that are damaged or severely rusted. Make sure precipitation has not entered indoor section of unit. X

Inspect electrical disconnect for proper function. Repair or replace as necessary. X Inspect electrical wiring and connections. Tighten loose connections. Inspect and perform functional test of equipment as needed to ensure proper function. Repair or replace damaged or overheated components and wiring. X

Inspect electric heater, if installed. Check for signs of overheating of elements, controls, and wiring. Make sure heater elements are not broken or electically shorted. X

Check refrigerant system subcooling and/or superheat (system dependent). X Inspect inside of unit. Clean if debris is present. X Inspect condenser coil. Clean if dust, dirt, or debris is present. Rinse unit with fresh water (see Note 2). X Inspect condenser motor and fan for damage. Make sure fan spins freely. X Inspect and clean blower assembly (includes blower housing, wheel, and motor). X Inspect evaporator coil. Clean if dust, dirt, or debris is present (see Note 2). X Clean condensate pan and drain lines (more frequent maintenance may be required in humid climates). X Inspect airflow system (ductwork). Check for leaks and repair as needed. X

Notes: 1. The above list may not include all maintenance items. Inspection intervals may vary depending on climate and operating hours. Consult your HVAC dealer about a service

contract for seasonal inspections. 2. Do not use harsh chemicals or high pressure water on coils. More frequent rinsing is required for units near a sea coast.

2020 Carrier. All rights reserved. A Carrier Company

Edition Date: 08

Manualsnet FAQs

If you want to find out how the 707E Bryant works, you can view and download the Bryant 707E Owner's Manual on the Manualsnet website.

Yes, we have the Owner's Manual for Bryant 707E as well as other Bryant manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Owner's Manual should include all the details that are needed to use a Bryant 707E. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Bryant 707E Owner's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Bryant 707E Owner's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Bryant 707E Owner's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Bryant 707E Owner's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Bryant 707E Owner's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.