Contents

Behringer LD6230 User's Manual PDF

1 of 11
1 of 11

Summary of Content for Behringer LD6230 User's Manual PDF

User Manual

EUROLIGHT LD6230 Professional 6-Channel 10 A Dimmer Pack with DMX and Analog Control

2 EUROLIGHT LD6230 User Manual

Table of Contents Important Safety Instructions ...................................... 3

Legal Disclaimer ............................................................. 3

Limited warranty ............................................................ 3

1. Introduction ............................................................... 4

1.1 Before you get started ...................................................... 4

1.2 The users manual ............................................................... 4

2. Control Elements ....................................................... 5

2.1 Configuration mode .......................................................... 6

2.2 DMX mode ............................................................................ 6

2.3 ANALOG mode ................................................................... 7

2.4 MANUAL mode ................................................................... 7

3. Applications ............................................................... 7

4. Connectors and Initial Operation ............................ 8

4.1 Digital DMX connector ..................................................... 8

4.2 Analog connector............................................................... 8

4.3 EEP (Eprom Check) ............................................................. 8

4.4 Phase allocation .................................................................. 8

5. Specifications ............................................................. 9

3 EUROLIGHT LD6230 User Manual

Important Safety Instructions

LEGAL DISCLAIMER

LIMITED WARRANTY

Terminals marked with this symbol carry electrical current of suffi cient magnitude to constitute risk of electric shock.

Use only high-quality professional speaker cables with " TS or twist-locking plugs pre-installed. All other installation or modifi cation should be performed only by qualifi ed personnel.

This symbol, wherever it appears, alerts you to the presence of uninsulated dangerous voltage inside the

enclosure - voltage that may be suffi cient to constitute a risk of shock.

This symbol, wherever it appears, alerts you to important operating and maintenance instructions in the

accompanying literature. Please read the manual.

Caution To reduce the risk of electric shock, do not remove the top cover (or the rear section).

No user serviceable parts inside. Refer servicing to qualifi ed personnel.

Caution To reduce the risk of fi re or electric shock, do not expose this appliance to rain and

moisture. The apparatus shall not be exposed to dripping or splashing liquids and no objects fi lled with liquids, such as vases, shall be placed on the apparatus.

Caution These service instructions are for use by qualifi ed service personnel only.

To reduce the risk of electric shock do not perform any servicing other than that contained in the operation instructions. Repairs have to be performed by qualifi ed service personnel.

1. Read these instructions.

2. Keep these instructions.

3. Heed all warnings.

4. Follow all instructions.

5. Do not use this apparatus near water.

6. Clean only with dry cloth.

7. Do not block any ventilation openings. Install in accordance with the manufacturers instructions.

8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifi ers) that produce heat.

9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fi t into your outlet, consult an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11. Use only attachments/accessories specifi ed by the manufacturer.

12. Use only with the cart, stand, tripod, bracket, or table specifi ed by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid

injury from tip-over.

13. Unplug this apparatus during lightning storms or when unused for long periods of time.

14. Refer all servicing to qualifi ed service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

15. The apparatus shall be connected to a MAINS socket outlet with a protective earthing connection.

16. Where the MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.

TECHNICAL SPECIFICATIONS AND APPEARANCES ARE SUBJECT TO CHANGE WITHOUT NOTICE AND ACCURACY IS NOT GUARANTEED. BEHRINGER, KLARK TEKNIK, MIDAS, BUGERA, AND TURBOSOUND ARE PART OF THE MUSIC GROUP (MUSIC-GROUP.COM). ALL TRADEMARKS ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS. MUSIC GROUP ACCEPTS NO LIABILITY FOR ANY LOSS WHICH MAY BE SUFFERED BY ANY PERSON WHO RELIES EITHER WHOLLY OR IN PART UPON ANY DESCRIPTION, PHOTOGRAPH OR STATEMENT CONTAINED HEREIN. COLORS AND SPECIFICATIONS MAY VARY FROM ACTUAL PRODUCT. MUSIC GROUP PRODUCTS ARE SOLD THROUGH AUTHORIZED FULLFILLERS AND RESELLERS ONLY. FULLFILLERS AND RESELLERS ARE NOT AGENTS OF MUSIC GROUP AND HAVE ABSOLUTELY NO AUTHORITY

TO BIND MUSIC GROUP BY ANY EXPRESS OR IMPLIED UNDERTAKING OR REPRESENTATION. THIS MANUAL IS COPYRIGHTED. NO PART OF THIS MANUAL MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM OR BY ANY MEANS, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING AND RECORDING OF ANY KIND, FOR ANY PURPOSE, WITHOUT THE EXPRESS WRITTEN PERMISSION OF MUSIC GROUP IP LTD.

ALL RIGHTS RESERVED. 2013 MUSIC Group IP Ltd. Trident Chambers, Wickhams Cay, P.O. Box 146, Road Town, Tortola, British Virgin Islands

For the applicable warranty terms and conditions and additional information regarding MUSIC Groups Limited Warranty, please see complete details online at www.music-group.com/warranty.

4 EUROLIGHT LD6230 User Manual

1. Introduction As a BEHRINGER EUROLIGHT LD6230 owner, you have a high-end dimmer pack at your hands. It was designed to answer to the high demands of lighting professionals working in television, theatres and live events, and is therefore universally applicable.

The EUROLIGHT LD6230 provides all necessary features for controlling your light show, yet it is clearly laid out and easy to use. It gives you the choice between analog and digital DMX control. Comprehensive LEDs let you easily detect signal problems so you can effortlessly eliminate them as soon as they occur.

The following users manual is intended to familiarize you with the units control elements, so that you can master all the functions. After having thoroughly read the users manual, store it at a safe place for future reference. Installation Instructions supplement the users manual and are included in the shipment.

A qualified professional needs to be present during the units installation and initial operation. More information about this topic is covered under Installation instructions.

1.1 Before you get started

1.1.1 Shipment

The LD6230 was carefully packed at the assembly plant to assure secure transport. Should the condition of the cardboard box suggest that damage may have occurred please inspect the unit immediately and look for physical indications of damage.

Damaged units should NEVER be sent directly to us. Please inform the dealer from whom you acquired the unit immediately as well as the transportation company from which you took delivery. Otherwise, all claims for replacement/repair may be rendered invalid.

1.1.2 Initial operation

Please make sure the unit is provided with sufficient ventilation, and never place the EUROLIGHT on top of an amplifier or in the vicinity of a heater to avoid the risk of overheating.

Please make sure that the unit is grounded at all times. For your own protection, you should never tamper with the grounding of the cable or the unit itself.

To avoid damage to your equipment, always make sure your dimmer pack is disconnected from the mains before you connect or disconnect spotlights or other lighting paraphernalia.

Make sure that only sufficiently qualified persons install and operate your LD6230. To avoid damage or altering of its performance through electrostatic discharge, make sure that all people handling the LD6230 are properly grounded both during and after the installation.

1.1.3 Rack installation

The LD6230 requires two height units (2 HU) when installed in a 19-inch rack. Please make sure to leave an extra 4 inches (10 cm) of space behind the unit for wiring.

Please use M6 machine screws and nuts to install your LD6230 into a rack.

1.1.4 Warranty

Please take a few minutes and send us the completely filled out warranty card within 14 days of the date of purchase. You may also register online at behringer.com. The serial number of your EUROLIGHT LD6230 ( (15) ) needed for registration is located at the rear panel of the unit. Failure to register your product may void future warranty claims.

1.2 The users manual The users manual is designed to give you both an overview of the controls, as well as detailed information on how to use them. In order to help you understand the links between the controls, we have arranged them in groups according to their function. If you need to know more about specific issues, please visit our website at http://behringer.com.

5 EUROLIGHT LD6230 User Manual

2. Control Elements Various LD6230 control elements are described in this chapter. All controls and connectors are described in detail, and you also get useful advice on how to use them in different applications.

(1) (2) (3) (4) (5)

(6) (7) (8)

Fig. 2.1: EUROLIGHT LD6230s front panel

(1) Ventilation openings are located on the front panel. Their position at the front assures that hot air does not enter the inside of your rack, causing equipment failure or damage.

To ensure that your dimmer pack runs smoothly even under full load, you have to make sure that there is enough distance to other heat-emitting equipment.

(2) There is an automated fuse for each of the six dimmer circles. These fuses engage in the event of overload or short circuit.

(3) Use the CHANNEL key to shift between the six dimmer channels. When used in combination with the CONFIG key (see (5) ), you can select different operating modes (DMX, ANALOG and MANUAL).

(4) Use the UP and DOWN keys to navigate through individual menus.

(5) The CONFIG key is used to activate the configuration mode (see ch. 2.1) and to select individual menus. When used in combination with the CHANNEL key (see (3)), you can select different operating modes.

(6) The LEDs to the left of the display have two purposes: supply phase status indication (L1, L2 und L3) and indication of the operating mode you selected (DMX, ANALOG and MANUAL).

(7) The 3-digit DISPLAY shows the values to be edited.

(8) The LEDs to the right of the display relate to the individual menus in the configuration mode. Depending on the selected function, the corresponding LED lights up.

(9) (10) (12) (14)

(13)(11) (15)

Fig. 2.2: EUROLIGHT LD6230s rear panel

(9) When your LD6230 works in DMX mode, use the 5-pole DMX512 IN-XLR connector to connect DMX512 control signals (see ch. 2.2 DMX mode and ch. 4.1 Digital DMX connector).

(10) You can relay the DMX control signal to additional dimmer packs by using the 5-pole DMX512 OUT XLR connector. If the dimmer is at the terminal end of a DMX chain, place a terminator at the DMX output of the dimmer pack to avoid signal bounce (use a terminator with the resistance of 120 between pins 2 and 3).

(11) You can connect an analog 0 - 10 V control signal to the 8-pole ANALOG IN DIN connector (see ch. 2.3 ANALOG mode and ch. 4.2 Analog connector).

(12) This is the cable slot for connecting your lighting equipment (see Installation Instructions).

(13) This is the cable slot for the power supply (see Installation Instructions).

(14) The cooling fan is located here.

(15) SERIAL NUMBER. Please take a few minutes and send us the completely filled out warranty card within 14 days of the date of purchase. Otherwise, warranty claims may be rendered invalid. You may also register online at behringer.com.

6 EUROLIGHT LD6230 User Manual

2.1 Configuration mode The important pre adjustments necessary for running the dimmer pack are done in the configuration mode. Keeping the CONFIG key pressed for roughly two seconds gets you into the configuration menu. Once you are in the configuration mode, keep using the CONFIG key to navigate through individual functions, which are indicated with their respective LEDs located to the right of the display. To get out of the configuration mode, keep the CONFIG pressed again for roughly two seconds.

All adjustments made in configuration mode are automatically stored when you exit, and remain stored even when you power the LD6230 on or off.

2.1.1 Address

As soon as you get to the configuration mode, the ADDRESS LED lights up. In this menu, you assign DMX basic channels (1 to 507) to the six dimmer channels. This address determines the DMX channel at which control commands are executed. Since you are dealing with a 6-channel dimmer, a maximum of six consecutive DMX channels can be interpreted as control signals, depending on the assignments in the ASSIGN menu (see ch. 2.1.2). If the start address value is 001, then the dimmer reacts to the first six channels of the DMX data stream. If you, for example, set the start address value to 024, then the dimmer reacts to the channels 024 to 029 correspondingly. If several units use the same DMX address, then they also receive the same control commands.

To select the desired DMX channels, use the UP and DOWN keys. When you keep one of these keys pressed while tapping the other one simultaneously, this lets you navigate through the channels in increments of 10 channels at a time.

2.1.2 Assign

When you press the CONFIG key once again, you get to the ASSIGN menu (ASSIGN LED lights up). In this menu you can make four different input channel/dimmer channel assignments. Possible configurations:

1-6: All six outputs are dependent on the setting of channel 1.

2-3: Outputs 1-3 are dependent on the setting of channel 1, and outputs 4-6 are dependent on the setting of channel 2.

3-2: Outputs 1 and 2 are dependent on the setting of channel 1, outputs 3 and 4 are dependent on the setting of channel 2, and outputs 5 and 6 are dependent on the setting of channel 3.

6-1: All six outputs are separately dependent on the respective six channels (1-6).

If you select one of the first three configuration options, you can for example form headlight groups that reproduce the same identical program since they are controlled through just one channel.

After you address DMX channels and assign input and dimmer channels, you should check if each dimmer circle reacts to the desired DMX control signal by moving the corresponding faders on the lighting console.

2.1.3 Preheat

When you press the CONFIG key once again, you get to the PREHEAT menu (the PREHEAT LED lights up). Use the UP and DOWN keys to enter the preheat value (0 to 15). This preheat value is then continuously run to the headlights, thus lowering the start-up current requirement and prolonging filament life. The preheat value you enter is valid for all six channels. However, the PREHEAT function cannot be used in switch mode (see ch. 2.1.5).

2.1.4 Limiter

When you press the CONFIG key once again, you get to the LIMITER menu (the LIMITER LED lights up). Use the CONFIG key to navigate through all six channels. Here you can set the upper limit for the control signal of each individual channel. Set the threshold value (16 to 99) by using the UP and DOWN keys. The LIMITER function too prolongs the life of your light equipment. Limiting the upper range of control voltage protects from voltage oscillations and overdrive.

2.1.5 Curve

When you press the CONFIG key once again, you get to the CURVE menu (the CURVE LED lights up). There are five possible ways to set up the transmission characteristic of your dimmer pack. You can determine how control voltage (i.e. fader movement on the mixing console) is transmitted to the lighting equipment. Step through the six channels indicated on the left-hand digit on the display by pressing the CONFIG key. Define the transmission characteristic for each channel separately by using the UP key.

LINEAR (L):

This transmission characteristic linearly increases or decreases control voltages in all segments of fader movement. When you move a fader on the lighting console, the headlight intensity changes directly proportionate to the fader movement.

EXPONENTIAL (o1):

In this case, the transmission curve is irregular. When you move the fader on the lighting console uniformly upwards, the voltage in the lower third of the faders range of movement increases linearly, whereas the transmission characteristic beyond the first third of the faders range of motion becomes more pronouncedly (exponentially) progressive with each increment of fader motion.

LOGARITHMIC (o2):

This transmission characteristic is also irregular. In the upper third of the faders range of motion the voltage changes linearly, whereas the transmission characteristic in the lower two thirds gets more pronouncedly degressive with each increment of fader motion. The logarithmic transmission curve is the opposite of the exponential curve.

SWITCH OPERATION (US = Unlimited Switch):

In this mode you can use the dimmer circle as a switch. This way, you can use your LD6230 to control fog machines, motors and various other effects. When the control voltage reaches 50% or more of a previously specified value, the channel is switched on. When the control voltage falls below 50%, the channel is switched off again. LIMITER and PREHEAT functions cannot be used in this mode.

SWITCH OPERATION (LS = Limited Switch):

In SWITCH OPERATION (LS) the limiter function can be used.

Transmission curves can be separately adjusted for each individual channel on the EUROLIGHT LD6230.

2.2 DMX mode Your LD6230 is automatically in DMX mode as soon as the power is up (DMX LED lights up). Navigate through different modes by using the CHANNEL key while simultaneously pressing the CONFIG key. Your LD6230 receives the DMX signal via the DMX512 IN connector, and this signal can be forwarded to additional dimmer packs using the DMX512 OUT connector in order to process additional channels. DMX512 IN and DMX512 OUT are 5-pole XLR connectors and are located on the rear panel.

7 EUROLIGHT LD6230 User Manual

2.2.1 DMX512

Data transmission in the field of lighting equipment refers to transmitting control information from the lighting console via the dimmer to the headlights, scanners and similar equipment. This process takes place by using the digital DMX512 control signal that was developed at the USITT (United States Institute for Theatre Technology). Information is no longer represented through analog voltage values; instead, digital data sets are used. In contrast to analog data transmission, digital signals can simply be patched together: each piece of information has an address to which it belongs. Additionally, the following goes for digital signals: when they arrive at their destination, they have the correct value since there is no loss of quality associated with analog signals.

Of course, problems may arise here as well. Very often, the reason for faulty transmissions lies in deploying wrong connectors or connectors other than those prescribed by the norm. Using wrong cables also may lead to faulty data transmission. We therefore only recommend using cables that are intended for use with digital audio technology.

The DMX standard contains 512 digital light channels that are controlled using a common data cable. However, a maximum of 32 different pieces of equipment can be connected to any one cable since the cable at some point becomes overburdened (due to shared controlling of all end equipment). Still, each piece of equipment can evaluate as much data as you wish. To connect additional pieces of equipment, you need a so-called splitter or a booster to amplify or to regenerate the DMX signal.

DMX512 is a compatible norm and requires only one data cable since all signal recipients are freely addressable, so you avoid having cable salad issues. Once all pieces of equipment are correctly connected and addressed, a DMX system typically works completely trouble-free.

2.3 ANALOG mode In addition to the digital DMX mode, your EUROLIGHT LD6230 dimmer pack also lets you work in ANALOG mode. You get to this mode by pressing the MODE key while the CONFIG key is pressed (the ANALOG LED lights up). The analog control signal (0 - 10 V) is transfered to the dimmer pack via an 8-pole DIN connector located on the rear panel. This way, you can use the LD6230 with analog control equipment.

In ANALOG mode, each dimmer channel has a control cable (or a core pair) of its own. The control signal runs through this cable. The output voltage of the dimmer is proportionate to the control cable signal. As a rule, 0% is represented by a voltage of 0 V, 50% is represented by a voltage of 5 V and 100% is represented by a voltage of 10 V.

When the dimmer pack receives a zero signal level at the input end, the output signal level should correspondingly be at its minimum. When the dimmer pack receives a maximum signal level at the input end, the output signal level should be at its maximum.

2.4 MANUAL mode To power up your lighting equipment, the EUROLIGHT dimmer pack can be used even without an external lighting console when in MANUAL mode (MANUAL LED lights up). In this mode, all settings are automatically saved every two seconds and can be recalled even after powering the LD6230 off and then on again. As with other operating modes, you get to MANUAL mode by pressing the CHANNEL key while the CONFIG key is kept pressed.

The left display digit indicates the channel selected with the CHANNEL key. The next two digits to its right indicate the level of the control signal, with values from 0 to 99. Use the UP and DOWN keys to adjust the control signal value.

3. Applications Lighting equipment is an integral part of almost every performance event and venue. Be it concerts, theatre or musical acts, clubs or even presentations and exhibits, they all benefit from good visuals in order to leave a lasting impression on the audience.

In general, lighting either creates a certain feeling or emphasizes the mood created through music or dramaturgic composition. Creating a lighting setup is a demanding and creative endeavour, since it is much more than merely making a set of lights go on and off. To do this, you need a dependable, multi-functional set of tools. The EUROLIGHT LD6230 offers a maximum on functionality and is the perfect expansion for a lighting console, preferably the BEHRINGER EUROLIGHT LC2412.

Thanks to digital DMX controlling, using multiple dimmer packs lets you implement demanding lighting setups, since you can control up to 32 components with only one DMX connection. These components dont necessarily have to be headlights; in switch mode, you can also control fog machines, pyrotechnic equipment or motors. This makes the LD6230 much more than just a piece of lighting equipment.

The following illustration shows a connection example with two EUROLIGHT LD6230s, a BEHRINGER EUROLIGHT LC2412 and BEHRINGER ULTRAPAR UP1000 headlights, whereby 12 light channels can be run. The first dimmer pack is controlled with the digital DMX control signal, the second one with an analog signal. If both dimmer packs are controlled with the DMX control signal, the second dimmer pack needs to receive the control signal via the first dimmer pack:

ULTRAPAR UP1000

Analog In

Analog Out

EUROLIGHT LC2412 Rear

DMX512 In

DMX512 Out

EUROLIGHT LD6230 Rear

Fig. 3.1: Connection example with the EUROLIGHT LC2412 and the ULTRAPAR UP1000 headlights

If you need more light channels, connect extra dimmer packs for processing your control signals.

8 EUROLIGHT LD6230 User Manual

4. Connectors and Initial Operation 4.1 Digital DMX connector The DMX512 IN and DMX512 OUT connectors are made in accordance with the international DMX512 standard. 5-pole XLR connectors are used, whereby controllers and DMX senders feature female connectors, while receiver equipment such as dimmer packs feature male connectors.

1 = Signal common/shield 2 = Data 1 (-) 3 = Data 2 (+)

5-pin XLR connectors for DMX512 signals

Pins 4 (data 2 -) and 5 (data 2 +) are not connected (optional use)

Fig. 4.1: Pin assignment of a 5-pin XLR connector

You should stick to the pin assignment shown in above illustration even when two reserve pins 4 and 5 are used for a second connection (a separate sender and receiver unit).

Often, 3-pole XLR connectors are also used for transmitting digital control signals, since these connectors simplify using the wiring already at the users disposal and are also less expensive than 5-pole connectors. However, these connectors are substandard and may not carry the DMX512 insignia.

4.2 Analog connector An 8-pole DIN connector is used as the input connection for an analog control signal (0-10 V).

PIN CHANNEL

1 1

2 2

3 3

4 4

5 5

6 6

7 NC

8 GROUND

Tab. 4.1: Pin assignment of an 8-pin DIN connector

4.3 EEP (Eprom Check) An eprom (Erasable Programmable Read Only Memory) is an electronic device that contains programs or data needed to operate a piece of equipment. Once you burn data onto an eprom, it cant get lost, even when you power down your equipment.

During the power-up procedure of your LD6230, the eprom is checked, that is, the LD6230 looks for false values (plausibility control). If irregularities occur during the eprom initialisation, factory default values are loaded.

To erase the contents of the eprom and load factory defaults, keep both middle keys (UP and DOWN) pressed while powering up your LD6230.

4.4 Phase allocation The LEDs L1, L2 and L3 ( (6)) indicate phase condition. L1 refers to channels 1 and 2, L2 refers to channels 3 and 4, and L3 refers to channels 5 and 6. The LEDs show if correct voltage is applied to your EUROLIGHT LD6230. If the voltage is not correct (i.e. too high or too low), the corresponding LED(s) begin to blink. Since the dimmers circuitry is powered by all three phases, the dimmer remains functioning even if two out of three phases malfunction. However, to guarantee trouble-free operation, always attempt to correct phase problems as soon as they are discovered.

9 EUROLIGHT LD6230 User Manual

5. Specifications

Channels

Number 6

Load per channel 0.2 A min./10 A max.

Maximal load per channel 10 A using a 3-phase connector

Frequency 50/60 Hz

Inputs

Power supply 3-phase connector, internal terminal block/PG cable screw joint, CEE connector (optional installation by qualified professional)

Analog 0 to +10 V via 8-pin DIN

Digital DMX512 via 5-pin XLR

Outputs

Digital DMX512 via 5-pin XLR

Load Internal terminal block/PG cable screw joint, HARTING (optional installation by qualified professional)

System Fuses

Load securing per channel 10 A cable protection switch (type C)

Control section fuse 2 x T 100 mA H/250 V (EU) 1 x T 160 mA H/250 V (EU) 2 x T 160 mA H/250 V (UL) 1 x T 315 mA H/250 V (UL)

Power Supply

Voltage

USA/Canada 120 V~, 60 Hz

Europe/U.K./Australia 240 V~, 50 Hz

Maximum power consumption 3 x 20 A

Dimensions/Weight

Dimensions (H x W x D) approx. 84.3 x 482.6 x 403.8 mm (approx. 3 1/3 x 19 x 15 9/10")

Weight approx. 9.80 kg (approx. 21.6 lbs)

BEHRINGER continuously strives to assure the highest quality standards possible. Required modifications may be implemented without prior notice. Technical data and the appearance of the unit may deviate from the above values and/or illustrations.

10 EUROLIGHT LD6230 User Manual

FEDERAL COMMUNICATIONS COMMISSION COMPLIANCE INFORMATION

Responsible Party Name: MUSIC Group Services US Inc.

Address: 18912 North Creek Parkway, Suite 200 Bothell, WA 98011, USA

Phone/Fax No.: Phone: +1 425 672 0816 Fax: +1 425 673 7647

EUROLIGHT LD6230

complies with the FCC rules as mentioned in the following paragraph:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Important information:

Changes or modifications to the equipment not expressly approved by MUSIC Group can void the users

Manualsnet FAQs

If you want to find out how the LD6230 Behringer works, you can view and download the Behringer LD6230 User's Manual on the Manualsnet website.

Yes, we have the User's Manual for Behringer LD6230 as well as other Behringer manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Manual should include all the details that are needed to use a Behringer LD6230. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Behringer LD6230 User's Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Behringer LD6230 User's Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Behringer LD6230 User's Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Behringer LD6230 User's Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the Behringer LD6230 User's Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.