Aver Auto Tracking Camera

PTC500S / PTC115

Control Codes 2021.3.30 v5

1

Product Introduction

Overview

1

2 3 4 5 6 7 8 9 10

1. PTZ camera 6. 3G-SDI 1 port(PTZ view)

2. Panoramic camera 7. HDMI port(PTZ view)

3. Power indicator 8. Audio in port*

4. RJ-45 port 9. RS-232 port

5. 3G-SDI 2 port(Panoramic view) 10. Power jack

*Audio input level: 1Vrms(max.)

2

RS232 Connection

RS232 Pin Definition

Din6 to D-Sub9 Cable Pin Definition

6 7 8

3 4 5

1 2

15

69

Pin Definition

1 RS232_DTR

2 RS232_DSR

3 N.C.

4 RS232_TXD

5 GND

6 RS232_RXD

3

Advanced Setting To adjust RS232 protocol, address and baud rate, select

Advance Setting from OSD menu.

OSD Tree

Tracking On

Camera

Video Format

Advanced Setting

Preset

Language

Profile

Factory Default

Information

>

>

>

>

>

>

>

>

Web Interface

Enable Visca-over-IP if needed.

RS232 Protocol

Address(ADDRD)

Baud Rate

VISCA-over-IP

VISCA

1

9600

off

4

RS232/422 VISCA Command Table

Command Set Command Command Packet Comments

IF_Clear 8x 01 00 01 FF x = Cam address

IF_Clear(broadcast) 88 01 00 01 FF

On 8x 01 04 00 02 FF

Off 8x 01 04 00 03 FF

Stop 8x 01 04 07 00 FF

Tele(Variable) 8x 01 04 07 2p FF

Wide(Variable) 8x 01 04 07 3p FF

Direct 8x 01 04 47 0Y 0Y 0Y 0Y FF 0xYYYY = zoom pos

Far(Variable) 8x 01 04 08 2P FF p=0~F

Near(Variable) 8x 01 04 08 3P FF p=0~F

Auto Focus 8x 01 04 38 02 FF

Manual Focus 8x 01 04 38 03 FF

One Push 8x 01 04 18 01 FF

Auto 8x 01 04 35 00 FF Normal Auto

One Push WB 8x 01 04 35 03 FF One Push WB mode

Manual 8x 01 04 35 05 FF Manual Control mode

One Push 8x 01 04 10 05 FF One Push WB Trigger

Up 8x 01 04 03 02 FF Manual Control of R Gain

Down 8x 01 04 03 03 FF

Up 8x 01 04 04 02 FF Manual Control of B Gain

Down 8x 01 04 04 03 FF

Full Auto 8x 01 04 39 00 FF Automatic Exposure mode

Manual 8x 01 04 39 03 FF Manual Control mode

Shutter Priority 8x 01 04 39 0A FF Shutter Priority Automatic Exposure mode

Iris Priority 8x 01 04 39 0B FF Iris Priority Automatic Exposure mode

Bright 8x 01 04 39 0D FF Bright Mode (Manual control)

Up 8x 01 04 0A 02 FF Shutter Setting

Down 8x 01 04 0A 03 FF

Up 8x 01 04 0B 02 FF Iris Setting

Down 8x 01 04 0B 03 FF

Up 8x 01 04 0D 02 FF Bright Setting

Down 8x 01 04 0D 03 FF

Up 8x 01 04 0E 02 FF Exposure Compensation Amount Setting

Down 8x 01 04 0E 03 FF

On 8x 01 04 33 02 FF Back Light Compensation ON/OFF

Off 8x 01 04 33 03 FF

reset 8x 01 04 3F 00 YY FF

set 8x 01 04 3F 01 YY FF

recall 8x 01 04 3F 02 YY FF

CAM_Menu On/Off 8x 01 06 06 10 FF Display ON/OFF

Up 8x 01 06 01 VV WW 03 01 FF

Down 8x 01 06 01 VV WW 03 02 FF

Left 8x 01 06 01 VV WW 01 03 FF

Right 8x 01 06 01 VV WW 02 03 FF

UpLeft 8x 01 06 01 VV WW 01 01 FF

UpRight 8x 01 06 01 VV WW 02 01 FF

DownLeft 8x 01 06 01 VV WW 01 02 FF

DownRight 8x 01 06 01 VV WW 02 02 FF

Stop 8x 01 06 01 VV WW 03 03 FF

Home 8x 01 06 04 FF

Reset 8x 01 06 05 FF

PT_Direct 8x 01 06 02 00 00 0Y 0Y 0Y 0Y 0V 0V 0V 0V FF 0xYYYY = pan position

0xVVVV = tilt position

CAM_Track_ON 8x 01 04 7D 02 00 FF

CAM_Track_OFF 8x 01 04 7D 03 00 FF

CAM_Profile_Read 8x 01 04 40 01 YY FF

CAM_Profile_Save 8x 01 04 40 02 YY FF

CAM_WOL_ON 8x 01 04 7E 02 00 FF

CAM_WOL_OFF 8x 01 04 7E 03 00 FF

CAM_PIP_SET 8x 01 04 7F 01 YY FF YY = pip num(0x01~0x09)

CAM_PIP_OFF 8x 01 04 7F 02 00 FF

YY = preset num(0~0x7F)

VV=pan speed: 0x00~0x0F

WW= tilt speed: 0x00~0x0F

YY = profile num(0x01~0x05)

CAM_Bright

CAM_Backlight

CAM_Preset

Pan-tilt Drive

CAM_WB

CAM_RGain

CAM_Bgain

CAM_AE

CAM_Shutter

CAM_Iris

CAM_ExpComp

CAM_Power *RS-232 support, over IP not support

CAM_Focus

CAM_Zoom p=0 (Low) to 7 (High)

5

Inquiry Command Command Packet Reply Packet Comments

y0 50 02 FF On

y0 50 03 FF Off

y0 50 00 FF Auto

y0 50 05 FF Manual

CAM_RGainInq 8x 09 04 43 FF y0 50 00 00 0p 0q FF pq: R Gain

CAM_BGainInq 8x 09 04 44 FF y0 50 00 00 0p 0q FF pq: B Gain

y0 50 00 FF Full Auto

y0 50 03 FF Manual

y0 50 0A FF Shutter Priority

y0 50 0B FF Iris Priority

y0 50 0D FF Bright

CAM_ShutterPosInq 8x 09 04 4A FF y0 50 00 00 0p 0q FF pq: Shutter Position

CAM_IrisPosInq 8x 09 04 4B FF y0 50 00 00 0p 0q FF pq: Iris Position

CAM_GainPosInq 8x 09 04 4C FF y0 50 00 00 0p 0q FF pq: Gain Position

CAM_BrightPosInq 8x 09 04 4D FF y0 50 00 00 0p 0q FF pq: Bright Position

CAM_ExpCompPosInq 8x 09 04 4E FF y0 50 00 00 0p 0q FF pq: ExpComp Position

CAM_VersionInq 8x 09 00 02 FF

PT_Pos_Inq 8x 09 06 12 FF y0 50 0Y 0Y 0Y 0Y 0V 0V 0V 0V FF 0xYYYY = pan position

0xVVVV = tilt position

Zoom_Pos_Inq 8x 09 04 47 FF y0 50 0Y 0Y 0Y 0Y FF 0xYYYY = zoom pos

Preset Inq 8x 09 04 3F FF y0 50 pp FF Return the last preset number which

has been operated pp:01 - FF

CAM_AEModeInq 8x 09 04 39 FF

8x 09 04 35 FFCAM_WBModeInq

CAM_PowerInq 8x 09 04 00 FF

The x value = VISCA Camera ID: 1 to 7 for RS232/RS422 connection.

Visca-over-IP Settings

The x value should be 1 for Visca-over-IP string, e.g. 01 00 00 09 00 00 00 01 81 01 06 01 07 07 01 03 FF

6

Pelco-P Command Table

Pelco-D Command Table

PAN AND TILT COMMANDSP/T bit(byte4.0) = 0

byte 1 byte 2 byte 3 byte 4 byte 5 byte 6 byte 7 byte 8

func STX ADDR data1 data2 data3 data4 ETX checksum

data 0xA0 0~7F cmd 1 cmd 2 Pan speed Tilt speed 0xAF 1~7 XOR

note : speed = 0x00~0x30

byte3 : command 1

bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0

NA CAM

ON NA

CAM

ON/OFF NA NA NA NA

note : power off : byte3.6 = 0 & byte3.4 = 1

byte4: command 2

bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0

NA ZOOM

Wide

ZOOM

Tele

TILT

Down

TILT

Up

PAN

Left

PAN

Right

P/T bit

0(always)

EXTENDED COMMAND SETP/T bit(byte4.0) = 1

byte 1 byte 2 byte 3 byte 4 byte 5 byte 6 byte 7 byte 8

func STX ADDR data1 data2 data3 data4 ETX checksum

Set Preset XX 0xA0 0~7 0x00 0x03 0x00 Preset # 0xAF 1~7 XOR

Go To Preset XX 0xA0 0~7 0x00 0x07 0x00 Preset # 0xAF 1~7 XOR

Track ON 0xA0 0~7 0x00 0x65 0x00 0x00 0xAF 1~7 XOR

Track OFF 0xA0 0~7 0x00 0x67 0x00 0x00 0xAF 1~7 XOR

WOL ON 0xA0 0~7 0x00 0x69 0x00 0x00 0xAF 1~7 XOR

WOL OFF 0xA0 0~7 0x00 0x6B 0x00 0x00 0xAF 1~7 XOR

Read Profile XX 0xA0 0~7 0x00 0x6D 0x00 Profile # 0xAF 1~7 XOR

Save To Profile XX 0xA0 0~7 0x00 0x6F 0x00 Profile # 0xAF 1~7 XOR

note : Preset # : 0x01 ~ 0xFF

Profile # : 0x01 ~ 0x05

PAN AND TILT COMMANDSP/T bit(byte4.0) = 0

byte 1 byte 2 byte 3 byte 4 byte 5 byte 6 byte 7

func SYNC ADDR cmd 1 cmd 2 data1 data2 checksum

data 0xFF 1~80 cmd 1 cmd 2 Pan speed Tilt speed 2~6 SUM

note : speed = 0x00~0x30

byte3 : command 1

bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0

SENSE

ON NA NA NA

CAM

ON/OFF NA NA NA

note : power off : byte3.7 = 0 & byte3.3 = 1

byte4: command 2

bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0

NA ZOOM

Wide

ZOOM

Tele

TILT

Down

TILT

Up

PAN

Left

PAN

Right

P/T bit

0(always)

EXTENDED COMMAND SETP/T bit(byte4.0) = 1

byte 1 byte 2 byte 3 byte 4 byte 5 byte 6 byte 7

func SYNC ADDR data1 data2 data3 data4 checksum

Set Preset XX 0xFF 1~8 0x00 0x03 0x00 Preset # 2~6 SUM

Go To Preset XX 0xFF 1~8 0x00 0x07 0x00 Preset # 2~6 SUM

Track ON 0xFF 1~8 0x00 0x65 0x00 0x00 2~6 SUM

Track OFF 0xFF 1~8 0x00 0x67 0x00 0x00 2~6 SUM

WOL ON 0xFF 1~8 0x00 0x69 0x00 0x00 2~6 SUM

WOL OFF 0xFF 1~8 0x00 0x6B 0x00 0x00 2~6 SUM

Read Profile XX 0xFF 1~8 0x00 0x6D 0x00 Profile # 2~6 SUM

Save To Profile XX 0xFF 1~8 0x00 0x6F 0x00 Profile # 2~6 SUM

note : Preset # : 0x01 ~ 0xFF

Profile # : 0x01 ~ 0x05

Example:

Camera Address: 1

Pan Left at high speed: FF 01 00 04 3F 00 44

Pan Right at medium speed: FF 01 00 02 20 00 23

Tilt Up at high speed: FF 01 00 08 00 3F 48

Tilt Down at medium speed: FF 01 00 10 20 00 31

Stop all actions (Pan / Tilt / Zoom / Iris etc.): FF 01 00 00 00 00 01

7

CGI Command Table

CGI item name URL Command Parameter Name Parameter value Description

Get MJPEG stream http://ip/livestream/livestream?action=get 640x360

Get RTSP stream rtsp://ip/live_st1

GET JPEG /webui?StartStreaming=ActionPTZ

/webui?SaveImage=Mod_cram_ptz1.jpg Mod_cram_ptz1.jpg ~ Mod_cram_ptz4.jpg

/Mod_cram_ptz1.jpg

CGI item name URL Command Parameter Name Parameter value Description

up start /webui?SetPtzf= 1,0,1&(random)

up end /webui?SetPtzf= 1,0,2&(random)

down start /webui?SetPtzf= 1,1,1&(random)

down end /webui?SetPtzf= 1,1,2&(random)

left start /webui?SetPtzf= 0,1,1&(random)

left end /webui?SetPtzf= 0,1,2&(random)

right start /webui?SetPtzf= 0,0,1&(random)

right end /webui?SetPtzf= 0,0,2&(random)

zoom_in start /webui?SetPtzf= 2,0,1&(random)

zoom_in end /webui?SetPtzf= 2,0,2&(random)

zoom_out start /webui?SetPtzf= 2,1,1&(random)

zoom_out end /webui?SetPtzf= 2,1,2&(random)

set preset: /webui?ActPreset= 1,N&(random) N : position

load preset: /webui?SetPtzf= 0,N&(random) N : position

CGI item name URL Command Parameter Name Parameter value Description

exposure value /webui?Set= img_expo_expo,3,N&(random) value 1 ~ 9 N : value

saturation /webui?Set= img_saturation,3,N&(random) value 0 ~ 10 N : value

contrast /webui?Set= img_contrast,3,N&(random) value 0 ~ 4 N : value

Tracking on: /webui?Set= trk_tracking,3,1&(random)

Tracking off: /webui?Set= trk_tracking,3,0&(random)

Reboot /webui?Set=reboot,3,1&X X : random value

Factory Reset /webui?OnePush=C_DEFAULT&X X : random value

Call Profile http://ip/webui?ActProFiles= call,3,N&(random) N= Profile number

Save Profile /webui?ActProFiles= save,3,N&(random) N= Profile number

Set Profile Name /webui?ActProNames= Set,N,(Name)&(random) N= Profile number

Tracking On/Off Get /webui?Get=trk_tracking,3&_=X PTC - Reply

On

trk_tracking=1

Off

trk_tracking=0

X : random value

Call Profile /webui?ActProFiles= call,3,N&(random) N= Profile number

Save Profile /webui?ActProFiles= save,3,N&(random) N= Profile number

Set Profile Name /webui?ActProNames= Set,N,(Name)&(random) N= Profile number

CGI List for Video Transmission

CGI

Manualsnet FAQs

If you want to find out how the PTC115 AVer works, you can view and download the AVer PTC115 Camera Control Codes Manual on the Manualsnet website.

Yes, we have the Control Codes Manual for AVer PTC115 as well as other AVer manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The Control Codes Manual should include all the details that are needed to use a AVer PTC115. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the AVer PTC115 Camera Control Codes Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This AVer PTC115 Camera Control Codes Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download AVer PTC115 Camera Control Codes Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print AVer PTC115 Camera Control Codes Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the AVer PTC115 Camera Control Codes Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.