ASUS ASMB4-iKVM Server User Manual PDF

1 of 84
1 of 84

Summary of Content for ASUS ASMB4-iKVM Server User Manual PDF

ASMB4-iKVM/ ASMB4-SOL PLUS

Server Management Board

ii

E6568

Second Edition V2 March 2011

Copyright 2011 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. (ASUS). Product warranty or service will not be extended if: (1) the product is repaired, modified or altered, unless such repair, modification of alteration is authorized in writing by ASUS; or (2) the serial number of the product is defaced or missing. ASUS PROVIDES THIS MANUAL AS IS WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL ASUS, ITS DIRECTORS, OFFICERS, EMPLOYEES OR AGENTS BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF PROFITS, LOSS OF BUSINESS, LOSS OF USE OR DATA, INTERRUPTION OF BUSINESS AND THE LIKE), EVEN IF ASUS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY DEFECT OR ERROR IN THIS MANUAL OR PRODUCT. SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FURNISHED FOR INFORMATIONAL USE ONLY, AND ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE, AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY ASUS. ASUS ASSUMES NO RESPONSIBILITY OR LIABILITY FOR ANY ERRORS OR INACCURACIES THAT MAY APPEAR IN THIS MANUAL, INCLUDING THE PRODUCTS AND SOFTWARE DESCRIBED IN IT. Products and corporate names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies, and are used only for identification or explanation and to the owners benefit, without intent to infringe.

iii

Contents

Notices ......................................................................................................... vi Safety information .................................................................................... viii About this guide ......................................................................................... ix ASMB4-iKVM/ASMB4-SOL PLUS specifications summary .................... xi

Chapter 1: Product introduction 1.1 Welcome! ...................................................................................... 1-2 1.2 Package contents ......................................................................... 1-2 1.3 Features ........................................................................................ 1-3 1.4 System requirements ................................................................... 1-4 1.5 Network setup .............................................................................. 1-5

Chapter 2: Installation 2.1 Before you proceed ..................................................................... 2-2 2.2 Hardware installation ................................................................... 2-2 2.3 Firmware update and IP configuration ....................................... 2-4

2.3.1 Firmware update ............................................................. 2-4 2.3.2 Configure BMC IP source static IP .................................. 2-6 2.3.3 Configure BMC IP source DHCP .................................... 2-7

2.4 BIOS configuration ...................................................................... 2-8 2.5 Running the ASMC4 utility ........................................................ 2-11

2.5.1 Configuring the LAN controller ...................................... 2-13 2.5.2 Configuring the user name and password .................... 2-14

2.6 Software installation .................................................................. 2-15 2.6.1 Installing the ARC ......................................................... 2-15 2.6.2 Launching ARC ............................................................. 2-16

Chapter 3: ASUS Remote Console 3.1 ASUS Remote Console (ARC) ..................................................... 3-2

3.1.1 ARC sections .................................................................. 3-3 3.1.2 Connecting to the remote server ..................................... 3-6 3.1.3 Retrieving sensor information ......................................... 3-8 3.1.4 Displaying FRU information .......................................... 3-10 3.1.5 Displaying system event logs .........................................3-11 3.1.6 Using Remote Console ................................................. 3-12 3.1.7 Displaying all remote server sensors ............................ 3-13

iv

Contents

3.1.8 Adjusting the monitoring settings .................................. 3-14 3.1.9 Controlling the remote server power ............................. 3-16 3.1.10 Viewing PET information ............................................... 3-17

3.2 ASUS Host Management Controller Setup ................................... 3-20 3.2.1 Installing and launching the ASUS Host

Management Controller Setup utility .................... 3-20 3.2.2 Command fields ............................................................ 3-21 3.2.3 Initial .............................................................................. 3-21 3.2.4 View .............................................................................. 3-21 3.2.5 Set ................................................................................. 3-24 3.2.6 Monitor .......................................................................... 3-25 3.2.7 Help ............................................................................... 3-26

Chapter 4: Web-based user interface 4.1 Web-based user interface ........................................................... 4-2

4.1.1 Loging in the utility .......................................................... 4-2 4.1.2 Using the utility ................................................................ 4-3

4.2 System Information ...................................................................... 4-4 4.3 Server Health ................................................................................ 4-4

4.3.1 Sensor Readings (with Thresholds) ................................ 4-5 4.3.2 Event Log ........................................................................ 4-5

4.4 Configuration ................................................................................ 4-6 4.4.1 Alerts ............................................................................... 4-6 4.4.2 PEF ................................................................................. 4-7 4.4.3 Mouse Mode ................................................................... 4-7 4.4.4 Network ........................................................................... 4-8 4.4.5 SMTP .............................................................................. 4-8 4.4.6 SSL ................................................................................. 4-9 4.4.7 Users ............................................................................... 4-9 4.4.8 Configure LDAP ............................................................ 4-10 4.4.9 Date/Time/NTP Settings ............................................... 4-10

4.5 Remote Control .......................................................................... 4-11 4.5.1 Console Redirection .......................................................4-11 4.5.2 Server Power Control .................................................... 4-12 4.5.3 Capture Screen Video ................................................... 4-12

v

Contents

4.5.4 Chassis Identify Command ........................................... 4-13 4.6 Maintenance ............................................................................... 4-13 4.7 Languages .................................................................................. 4-14

Appendix: Reference information A.1 BMC connector .............................................................................A-2 A.2 LAN ports for server management .............................................A-3 A.3 Troubleshooting ...........................................................................A-4 A.4 BMC Sensor Codes Table ............................................................A-5

vi

Notices

Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received including interference that

may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with manufacturers instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment to an outlet on a circuit different from that to which the

receiver is connected. Consult the dealer or an experienced radio/TV technician for help.

The use of shielded cables for connection of the monitor to the graphics card is required to assure compliance with FCC regulations. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the users authority to operate this equipment.

Canadian Department of Communications Statement This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.

This class B digital apparatus complies with Canadian ICES-003.

vii

REACH Complying with the REACH (Registration, Evaluation, Authorization, and Restriction of Chemicals) regulatory framework, we published the chemical substances in our products at ASUS website at http://csr.asus.com/english/ REACH.htm.

ASUS Recycling/Takeback Services ASUS recycling and takeback programs come from our commitment to the highest standards for protecting our environment. We believe in providing solutions for you to be able to responsibly recycle our products, batteries, other components as well as the packaging materials. Please go to http://csr.asus.com/english/Takeback.htm for detailed recycling information in different regions.

DO NOT throw the motherboard in municipal waste. This product has been designed to enable proper reuse of parts and recycling. This symbol of the crossed out wheeled bin indicates that the product (electrical and electronic equipment) should not be placed in municipal waste. Check local regulations for disposal of electronic products.

DO NOT throw the mercury-containing button cell battery in municipal waste. This symbol of the crossed out wheeled bin indicates that the battery should not be placed in municipal waste.

viii

Safety information Electrical safety To prevent electrical shock hazard, disconnect the power cable from the

electrical outlet before relocating the server. When adding or removing devices to or from the server, ensure that the power

cables for the devices are unplugged before the signal cables are connected. If possible, disconnect all power cables from the existing server before you add a device.

Before connecting or removing signal cables from the server, ensure that all power cables are unplugged.

Seek professional assistance before using an adapter or extension cord. These devices could interrupt the grounding circuit.

Make sure that your power supply is set to the correct voltage in your area. If you are not sure about the voltage of the electrical outlet you are using, contact your local power company.

If the power supply is broken, do not try to fix it by yourself. Contact a qualified service technician or your retailer.

Operation safety Before installing any component to the server, carefully read all the manuals

that came with the package. Before using the product, make sure all cables are correctly connected and the

power cables are not damaged. If you detect any damage, contact your dealer immediately.

To avoid short circuits, keep paper clips, screws, and staples away from connectors, slots, sockets and circuitry.

Avoid dust, humidity, and temperature extremes. Do not place the product in any area where it may become wet.

Place the product on a stable surface. If you encounter technical problems with the product, contact a qualified

service technician or your retailer.

ix

About this guide This user guide contains the information you need when installing and configuring the server management board.

How this guide is organized This guide contains the following parts:

Chapter 1: Product introduction This chapter describes the server management board features and the new technologies it supports.

Chapter 2: Installation This chapter provides instructions on how to install the board to the server system and install the utilities that the board supports.

Chapter 3: ASUS Remote Console This chapter tells you how to use the ASUS Remote Console (ARC) that the server management board supports.

Chapter 4: Web-based user interface (ASMB4-iKVM only) This chapter tells you how to use the web-based user interface that the server management board supports.

Appendix: Reference Information The Appendix shows the location of the LAN ports for server management and BMC connector on server motherboards. This section also presents common problems that you may encounter when installing or using the server management board.

Where to find more information Refer to the following sources for additional information and for product and software updates.

1. ASUS websites The ASUS website provides updated information on ASUS hardware and software products. Refer to the ASUS contact information.

2. Optional documentation Your product package may include optional documentation, such as warranty flyers, that may have been added by your dealer. These documents are not part of the standard package.

x

Typography Bold text Indicates a menu or an item to select.

Italics Used to emphasize a word or a phrase.

Keys enclosed in the less-than and greater-than sign means that you must press the enclosed key.

Example: means that you must press the Enter or Return key.

If you must press two or more keys simultaneously, the key names are linked with a plus sign (+). Example:

Command Means that you must type the command exactly as shown, then supply the required item or value enclosed in brackets. Example: At the DOS prompt, type the command line: format a:

DANGER/WARNING: Information to prevent injury to yourself when trying to complete a task.

CAUTION: Information to prevent damage to the components when trying to complete a task.

NOTE: Tips and additional information to help you complete a task.

IMPORTANT: Instructions that you MUST follow to complete a task.

Conventions used in this guide To make sure that you perform certain tasks properly, take note of the following symbols used throughout this manual.

xi

ASMB4-iKVM/ASMB4-SOL PLUS specifications summary

Chipset Aspeed 2050 Internal RAM 56 Mb for system

8 Mb for video Internal ROM 16 Mb Timers 32-bit Watchdog Timer

Main features IPMI 2.0-compliant and supports KVM over LAN Web-based user interface (remote management) Virtual media

Form factor 22 mm x 17 mm

* Specifications are subject to change without notice.

xii

1Chapter 1: Product introduction

This chapter describes the server management board features and the new technologies it supports.

1-2 Chapter 1: Product introduction

1.1 Welcome! Thank you for buying an ASUS ASMB4-iKVM/ASMB4-SOL PLUS server management board!

The ASUS ASMB4-iKVM/ASMB4-SOL PLUS is an Intelligent Platform Management Interface (IPMI) 2.0-compliant board that allows you to monitor, control, and manage a remote server from the local or central server in your local area network (LAN). With ASMB4-iKVM/ASMB4-SOL PLUS plugging in a server motherboard, you can completely and efficiently monitor your server in real- time. The solution allows you to reduce IT management costs and increase the productivity.

Before you start installing the server management board, check the items in your package with the list below.

If any of the above items is damaged or missing, contact your retailer.

1.2 Package contents Check your server management board package for the following items.

ASUS ASMB4-iKVM/ASMB4-SOL PLUS board Support CD User guide

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 1-3

1.3 Features

1. IPMI 2.0 System interface (KCS) LAN interface (support RMCP+) System Event Log (SEL) Sensor Data Record (SDR) Field Replaceable Unit (FRU) Remote Power on/off, reboot Serial Over LAN (SOL) Authentication Type: RAKP-HMAC-SHA1 Encryption (AES) Platform Event Filtering (PEF) Platform Event Trap (PET) Watchdog Timer

2. Private I2C Bus Auto Monitoring sensors (temperature, voltage, fan speed and logging

events

3. PMBus* Support Power supply for PMBus device

4. PSMI* Support Power supply for PSMI bus device

5. Web-base GUI Monitor Sensor, show SDR, SEL, FRU, configure BMC, LAN Support SSL (HTTPS) Multiple user permission level Upgrade BMC firmware

6. Update Firmware DOS Tool Web GUI (Windows XP/Vista/2003/2008, RHEL5.2, SLES10SP2

7. Notification PET SNMP Trap e-Mail

1-4 Chapter 1: Product introduction

1.4 System requirements Before you install the ASMB4-iKVM/ASMB4-SOL PLUS board, check if the remote server system meets the following requirements:

ASUS server motherboard with Baseboard Management Controller (BMC) connector*

LAN (RJ-45) port for server management** Microsoft Internet Explorer 5.5 or later; Firefox

* Visit the ASUS website (www.asus.com) for an updated list of server motherboards that support the ASMB4-iKVM/ASMB4-SOL PLUS.

** See the Appendix for details.

* A power supply supported PMBus and PSMI is necessary. ** Specifications are subject to change without notice.

8. KVM over Internet (ASMB4-iKVM only) Web-based remote console

9. Remote Update BIOS (ASMB4-iKVM only) Use Remote floppy to update BIOS

10. Remote Storage (Virtual Media) (ASMB4-iKVM only) Support two remote storage for USB/CD-ROM/DVD and image

11. Remote Install OS (ASMB4-iKVM only) Use remote storage to remote install OS

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 1-5

1.5 Network setup The ASMB4-iKVM/ASMB4-SOL PLUS server management board installed on the remote server connects to a local/central server via direct LAN connection or through a network hub. Below are the supported server management configurations.

Remote server with ASMB4-iKVM/ ASMB4-SOL PLUS

Hub or router

Direct LAN connection

LAN connection through a network hub

Remote server with ASMB4-iKVM/ ASMB4-SOL PLUS

RJ-45 cable

Remote console with web-based browser

Remote console with web-based browser

1-6 Chapter 1: Product introduction

2Chapter 2: Installation

This chapter provides instructions on how to install the board to the server system and install the utilities that the board supports.

2-2 Chapter 2: Installation

2.2 Hardware installation

To install the server management board:

1. Remove the remote server system cover, and then locate the Baseboard Management Controller (BMC) connector on the motherboard.

2.1 Before you proceed Take note of the following precautions before you install the server management board to the remote server system.

Unplug the server system power cord from the wall socket before touching any component.

Use a grounded wrist strap or touch a safely grounded object or to a metal object, such as the power supply case, before handling components to avoid damaging them due to static electricity.

Hold components by the edges to avoid touching the ICs on them.

Whenever you uninstall any component, place it on a grounded antistatic pad or in the bag that came with the component.

Before you install or remove any component, ensure that the power supply is switched off or the power cord is detached from the power supply. Failure to do so may cause severe damage to the motherboard, peripherals, and/or components.

2. Place the board on the BMC connector of the motherboard, aligning with the pin connectors.

Refer to the Appendix section for the location of the BMC connector on supported motherboards.

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 2-3

4. When installed, the board appears as shown.

5. Reinstall the remote server system cover, then connect the power plug to a grounded wall socket.

Everytime after the AC power is re-plugged, you have to wait for about 30 seconds for the system power up.

6. Insert the LAN cable plug to the LAN port for server management.

Refer to the Appendix for the location of the LAN port for server management.

7. For direct LAN configuration, connect the other end of the LAN cable to the local/central server LAN port.

For connection to a network hub or router, connect the other end of the LAN cable to the network hub or router.

3. Press the board firmly until it is completely seated in place.

2-4 Chapter 2: Installation

2.3 Firmware update and IP configuration You need to update the ASMB4-iKVM/ASMB4-SOL PLUS firmware and configure IP source before you start using the ASMB4-iKVM/ASMB4-SOL PLUS board.

2.3.1 Firmware update To update the firmware: 1. Insert the support CD into the optical drive. 2. Restart the remote server, then press during POST to enter the BIOS

setup. 3. Go to Boot menu and set the Boot Device Priority item to [CD-ROM]. 4. When finished, press to save your changes and exit the BIOS setup. 5. On reboot, the main menu appears. Select ASMB4-iKVM (or ASMB4-SOL

PLUS) Firmware Update for Preserve Configuration, and press to enter the sub-menu.

6. A confirmation message appears, asking whether you want to update the firmware or not. Select to update.

ASUS Server Z8PE-D12X MB FreeDOS command prompt Configure BMC IP Source Static IP for LAN1 Configure BMC IP Source DHCP for LAN1 Configure BMC IP Source Static IP for LAN3 Configure BMC IP Source DHCP for LAN3 ASMB4-iKVM Firmware Update for Preserve Configuration ASMB4-iKVM Firmware Update for Clear Configuration

The firmware updating process starts.

WARNING !!! UPDATE ASMB4-iKVM FIRMWARE NOW ! DO YOU WANT TO CONTINUE ?

No Yes

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 2-5

7. When the update process is completed, the following screen appears.

NewImageSize = 10MB, offs = 0

Uploading Firmware Image : Completed

Flash Update Completed

Device Firmware has been upgraded successfully. The device will be reset within 10 seconds for the new firmware to take effectt. Press any key to continue ...

You may update firmware from the web-based user interface. Refer to page 4-13 for details.

2-6 Chapter 2: Installation

2.3.2 Configure BMC IP source static IP 1. Repeat the step 1-4 in the previous sub-section. 2. On reboot, the main menu appears.Select Configure BMC IP Source Static IP

for LAN1 (or LAN3), and press to enter the sub-menu.

4. When the configuration is completed, the below screen appears.

3. A confirmation message appears, asking if you want to configure the BMC IP source static IP now. Select to continue.

Detect Motherboard -> (Z8PE-D12X)

Detect KCS Interface

New BMC IP Source : Static IP

Press any key to continue ...

5. Go to BIOS menu to set the IP. Refer to section 2.4 for IP settings in BIOS menu.

ASUS Server Z8PE-D12X MB FreeDOS command prompt Configure BMC IP Source Static IP for LAN1 Configure BMC IP Source DHCP for LAN1 Configure BMC IP Source Static IP for LAN3 Configure BMC IP Source DHCP for LAN3 ASMB4-iKVM Firmware Update for Preserve Configuration ASMB4-iKVM Firmware Update for Clear Configuration

WARNING !!! CONFIGURE BMC IP Source STATIC IP NOW ! DO YOU WANT TO CONTINUE ?

No Yes

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 2-7

2.3.3 Configure BMC IP source DHCP 1. Repeat the step 1-4 in the previous sub-section. 2. On reboot, the main menu appears.Select Configure BMC IP Source DHCP for

LAN1 (or LAN3), and press to enter the sub-menu.

4. When the configuration is completed, the below screen appears.

3. A confirmation message appears, asking if you want to configure the BMC IP source DHCP now. Select to continue.

Detect Motherboard -> (Z8PE-D12X)

Detect KCS Interface

New BMC IP Source : DHCP

Press any key to continue ...

5. Then you can get IP from DHCP server.

ASUS Server Z8PE-D12X MB FreeDOS command prompt Configure BMC IP Source Static IP for LAN1 Configure BMC IP Source DHCP for LAN1 Configure BMC IP Source Static IP for for LAN3 Configure BMC IP Source DHCP for for LAN3 ASMB4-iKVM Firmware Update for Preserve Configuration ASMB4-iKVM Firmware Update for Clear Configuration

WARNING !!! CONFIGURE BMC IP Source DHCP NOW ! DO YOU WANT TO CONTINUE ?

No Yes

2-8 Chapter 2: Installation

2.4 BIOS configuration You need to adjust the settings in the BIOS setup of the remote server for correct configuration and connection to the central server.

Update the remote server BIOS file following the instructions in the motherboard/system user guide. Visit the ASUS website (www.asus.com) to download the latest BIOS file for the motherboard.

The BIOS setup screens shown in this section are for reference purposes only, and may not exactly match what you see on your screen.

Running the BIOS IPMI configuration To configure the IPMI in the BIOS:

1. Restart the remote server, then press during POST to enter the BIOS setup.

2. Go to the Server menu, then select the IPMI Configuration sub-menu. Use this sub-menu to configure the IPMI settings.

3. When finished, press to save your changes and exit the BIOS setup.

IPMI Configuration

Select Screen Select Item

Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

BIOS SETUP UTILITY Server

IPMI Configuration

BMC Firmware version : 1.03 Set LAN1 Configuration Set LAN3 Configuration View BMC System Event Log

Clear BMC System Event Log BMC Watch Dog Timer Action [Disabled]

InPut for Set LAN Configuration command. See IPMI 1.5 Spec, table 19.1 NOTE:- Each question in this group may take considerable amount of time.

Select Set LAN1 Configuration for shared LAN; select Set LAN3 Configuration for dedicated LAN.

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 2-9

Set LAN1/LAN3 Configuration Allows you to set the BMC LAN Parameter settings.

IP Address Source Allows you to select the IP address source type. When set to [Static Mode], the following three items become configurable, and you have to assign the IP address, subnet mask and gateway address for the remote server. When set to [DHCP Mode], you dont have to assign the IP address, subnet mask and gateway address for the remote server.

IP Address Allows you to set the BMC IP address.

Subnet Mask Allows you to set the BMC subnet mask. We recommend that you use the same Subnet Mask you have specified on the operating system network for the used network card.

Gateway Address Allows you to set the gateway address. We recommend that you use the same gateway address you have specified on the operating system network for the used network card.

Select Screen Select Item

+- Change Option F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

BIOS SETUP UTILITY Server

LAN Configuration.

Current IP address in BMC: 010.010.010.243 Current Subnet Mask in BMC: 255.255.255.0 Current Gateway Address in BMC: 000.000.000.000 Current MAC address in BMC: 00.10.20.3D.40.5F

IP Address Source [Static Mode] IP Address [000.000.000.000] Subnet Mask [000.000.000.000] Gateway Address [000.000.000.000]

DHCP Mode Static Mode

Options

2-10 Chapter 2: Installation

It is necessary to install ASWM (ASUS System Web-based Management) for using this function.

Select Screen Select Item

+- Change Option F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

BIOS SETUP UTILITY Server

Total Number Of Entries: 700

SEL Entry Number: [ 1] SEL Record ID: 0001 SEL Record Type: 02 (System Event) Event Timestamp: Jan 1, 2008 00:00:06 Generator ID: 0020 Event Message Rev: 04 (IPMI ver 1.5) Event Sensor Type: 02 (Voltage) Event Sensor Number: 35 (CPU Vcore 2) Event Dir Type: 01 Event Data: 50 00 7D

Use +/- to traverse the event log.

View BMC System Event Log Allows you to view all the events in the BMC event log. It will take a maximum of 15 seconds to read all the BMC SEL records.

Clear BMC System Event Log Allows you to clear the system event log. Press to go to the sub screen, and then select Ok to clear BMC System Event Log.

BMC Watch Dog Timer Action [Disabled] Allows the BMC to reset or power down the system when the operating system crashes or hangs. Configuration options: [Disabled] [Reset System] [Power Down] [Power Cycle]

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 2-11

2.5 Running the ASMC4 utility The ASMC4 utility allows you to update the ASMB4-iKVM/ASMB4-SOL PLUS firmware, configure the LAN setting for the remote server and change the user name/ password in DOS environment. This utility is available from the support CD that came with the package.

To run the ASMC4 utility:

1. Insert the support CD into the optical drive. 2. Restart the remote server, then press during POST to enter the BIOS

setup. 3. Go to Boot menu and set the Boot Device Priority item to [CD-ROM]. 4. When finished, press to save your changes and exit the BIOS setup. 5. On reboot, the main menu appears. Select FreeDOS command prompt, and

then press .

ASUS Server Z8PE-D12X MB FreeDOS command prompt Configure BMC IP Source Static IP for LAN1 Configure BMC IP Source DHCP for LAN1 Configure BMC IP Source Static IP for for LAN3 Configure BMC IP Source DHCP for for LAN3 ASMB4-iKVM Firmware Update for Preserve Configuration ASMB4-iKVM Firmware Update for Clear Configuration

Refer to the table on the next page for a description of the help menu options.

6. When the C:> prompt appears, type ASMC4 -?, then press to display the ASMC4 Utility Help Menu. The screen appears as shown.

2-12 Chapter 2: Installation

ASMC4 Help Menu options

Options Description -kcs[smic/bt/pci_smic] NetFn command data.... Send IPMI command -bmc_ip_source source[1: Static, 2: DHCP] Set the IP source -bmc_ip [ip_addr] (e.g., bmc_ip 10.10.10.20)

Write the BMC IP address for dedicated LAN

-bmc_mask [ip_mask] (e.g., bmc_mask 255.255.255.0)

Write the subnet mask for dedicated LAN

-bmc_gateway [ip_addr] (e.g., bmc_gateway 10.10.10.254)

Write the gateway address for dedicated LAN

-pet_ip_mac [ip_addr] [mac_addr] (e.g., pet_ip_mac 10.10.10.20 010203040506)

Write the PET destination IP and MAC addresses for dedicated LAN

-bmc_ip_s_lan1 source[1: Static, 2: DHCP] Set the IP source for shared LAN -bmc_ip_lan1 [ip_addr] (e.g., bmc_ip 10.10.10.20)

Write the BMC IP address for shared LAN

-bmc_mask_lan1 [ip_mask] (e.g., bmc_mask 255.255.255.0)

Write the subnet mask for shared LAN

-bmc_g_lan1 [ip_addr] (e.g., bmc_gateway 10.10.10.254)

Write the gateway address for shared LAN

-pet_ip_m_lan1 [ip_addr] [mac_addr] (e.g., pet_ip_mac 10.10.10.20 010203040506)

Write the PET destination IP and MAC addresses for shared LAN

-adm_name new_name_string Change the administration name -user_name new_name_string Change the user name -adm_password new_adm_password Change the administration password -user_password new_user_password Change the user password -sol_baud [baud rate] (e.g., sol_baud 57600)

Set the communication Baud rate

-bmc_info Displays the BMC and PET IP and MAC addresses

-fru -view fru_id Displays the system FRU information -fru -load fru_file Update system FRU data from file -fru -save fru_id fru_file Save system FRU data to file -sel -clear Clear system event log

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 2-13

2.5.1 Configuring the LAN controller Before you can establish connection to the ASMB4-iKVM/ASMB4-SOL PLUS board, you must configure the LAN port for server management used by the remote server to connect to the local/central server.

To configure the LAN port of the remote server:

1. Run the ASMC4 utility from the support CD following the instructions in the previous section.

2. Set IP source: (a) Type asmc4 -bmc_ip_source 1 if you want to set a static IP address. (b) Type asmc4 -bmc_ip_source 2 if you want to get IP from DHCP server. 3. Type asmc4 -bmc_ip xxx.xxx.xxx.xxx, then press to assign any IP

address to the remote server LAN port (if necessary). The screen displays the request and response buffer. Write the remote server IP address in a piece of paper for reference. c:\>asmc4 -bmc_ip 10.10.10.243 Detect MotherBoard -> (Z8PE-D12X) Detect KCS Interface New BMC IP : 10.10.10.243 c:\>

When finished, the utility returns to the DOS prompt.

Make sure that the assigned IP address for both remote and local/central servers are in the same subnet. You can use the network settings utility in your OS to check.

4. Configure your (a) subnet mask and (b) gateway address if necessary. (a) Type asmc4 -bmc_mask xxx.xxx.xxx.xxx (your subnet mask encoded in

hexadecimal system) (b) Type asmc4 -bmc_gateway xxx.xxx.xxx.xxx (your gateway address

encoded in hexadecimal system) 5. Restart the remote server, enter the BIOS setup, then boot from the hard disk

drive. 6. Adjust the local/central server network settings, if necessary.

2-14 Chapter 2: Installation

2.5.2 Configuring the user name and password You may change your user name and password from the ASMC4 utility.

To change the user name and password:

1. Follow steps 1-5 on page 2-11. 2. When the C:> prompt appears, type asmc4 -user_name xxxxx, then

press to change the user name.

C:\>asmc4 -user_name super Detect MotherBoard -> (Z8PE-D12X) Detect KCS Interface Change User Name to super C:\>

3. Type asmc4 -user_password xxxxxxxx, then press to change the password.

4. Restart the remote server, enter the BIOS setup, then boot from the hard disk drive.

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 2-15

2.6 Software installation You can monitor, control, or manage the remote server from the local/central server using the ASUS Remote Console (ARC). The ARC is a web-based application available from the support CD that came with theASMB4-iKVM/ASMB4-SOL PLUS package. You must install the ARC on the local/central server to access the remote server.

2. Click the Utilities tab, then click the item ASUS Remote Console.

If Autorun is NOT enabled in your computer, browse the contents of the support CD to locate the file ARC.EXE in the ARC folder. Double-click the ARC.EXE to install the application.

Before you install the ARC:

For SNMP Service: View the Platform Event Trap (PET) information. See page 3-17 for details.

For Microsoft ActiveSync: Enable the SMS feature. See page 3-15 for details.

2.6.1 Installing the ARC To install the ARC to the local/central server:

1. Place the support CD to the optical drive. The CD automatically displays the Drivers menu if Autorun is enabled in your computer.

2-16 Chapter 2: Installation

3. Follow the installation wizard instructions to install the utility.

2.6.2 Launching ARC To launch the ARC utility, click Start > All Programs > ASUS Remote Console > ASUS Remote Console from the Windows desktop.

OR

Double-click the ASUS Remote Console icon on the Windows desktop.

3Chapter 3: ASUS Remote Console

This chapter tells you how to use the ASUS Remote Console (ARC) that the server management board supports.

3-2 Chapter 3: ASUS Remote Console

3.1 ASUS Remote Console (ARC) The ASUS Remote Console (ARC) is a web-based utility, designed for ASMB4-SOL PLUS, that allows you to monitor the remote hosts hardware information including temperatures, fan rotations, voltages, and power. This application also lets you instantly power on/off or reset the remote server.

The ARC window is made up of six sections:

1. Menu bar 2. Tool bar 3. Navigation window 4. Detail/SEL window 5. Event window 6. Status bar

Refer to the following sections for details.

2

43

5 6

1

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-3

3.1.1 ARC sections

Menu bar The Menu bar contains all the commands for the ARC application. Click on a menu to display a list of available commands.

Tool bar The Tool bar buttons correspond to commonly used commands. The Tool bar offers faster access and execution of these commands. Roll the mouse pointer over a button to display its function.

Navigation window The Navigation window displays the directory of connected and disconnected remote server(s). For multiple monitoring, this window allows you to navigate through the remote servers. Click the All Servers root directory to display all connected and disconnected servers, then click on the server you want to monitor or control.

Click before the server connection to display available remote server information including the SDR (Sensor Data Record), FRU (Field Replaceable Unit), SEL (System Event Log), and Remote Console.

Menu Available commands Server add, delete, connect, disconnect server or change the server

settings; load/save server node list; general setting; dump/restore all configuration

View show or hide the tool bar, status bar, navigation, and PET windows Control power down/up, reset, power cycle, power on Lan Edit delete the System Event Log (SEL), PET log, Reset PET destination,

Reset Baud Rate; Set MAC address Help open Help contents or view information about the ARC application

3-4 Chapter 3: ASUS Remote Console

Some remote server information (such as the SDR) contains several sensor groups such as Temperature, Voltage, and Fan. Click before the remote server information to display the sensor groups.

Click before a sensor group to display individual sensors. For example, clicking before the sensor group Temperature displays the CPU1 and system temperatures.

You can also change the server directory display by clicking the buttons on top of the window. For example, clicking the IP button displays the remote server IP address instead of the remote server name (N). Selecting ID displays the remote server ID instead of the server name or IP address.

Sensor groups Sensors

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-5

Event window The Event window displays the Platform Event Trap (PET) received by the ARC. The PET information includes the event index, source IP address, enterprise, community, generic and specific traps, and time ticks. The PET information is a system management alert in SNMP Trap format and is used for IPMI alerting.

Status bar The Status bar located at the bottom of the ARC window displays the connection status to the remote server, connection duration, IP address of the remote server, and the progress of SDR/SEL/FRU information download.

Detail/SEL window The Detail/SEL window displays the detailed SDR and FRU information, and the SEL (System Event Log). The window provides the link for detailed sensor information or system events and allows you to adjust the sensor threshold values.

3-6 Chapter 3: ASUS Remote Console

3.1.2 Connecting to the remote server To connect to the remote server:

1. From the menu bar, click Server, then select Add New Server Node. An Add new server connection window appears.

2. Type the remote server name and IP address on the fields. Click Save Default to set the remote server connection as the default. Otherwise, click OK to continue or Cancel to close the window.

The default server connection name and IP address are automatically displayed everytime you add a new server connection.

3. When prompted, select IPMI Server, then click Continue.

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-7

The navigation window displays the remote server. The available remote server information are displayed on the Detail/SEL window.

4. Use any of these options to connect to the server: Click before the remote server to display the remote server information,

then select from the list. Double-click a remote server information from the Detail/SEL window. Click Server, then select Connect.

5. When prompted, enter the default user name (admin) and password (admin).

6. Set the connection request level authentication and privilege, then click OK.

The default connection request level authentication is HMAC-SHA1 with Administrator privileges. You may change these configuration according to your network settings or preference.

Check the box before Enable Payload Encryption if you want to use Advanced Encryption Standard (AES).

3-8 Chapter 3: ASUS Remote Console

3.1.3 Retrieving sensor information The Sensor Data Record (SDR) provides remote server system information through available sensors including CPU/system/power temperatures, voltages, fan speeds, chassis intrusion, etc. The SDR also provides information on the sensor location (e.g. CPU1, CPU2, FAN1), event generation, and access information.

To retrieve a sensor information:

1. From the navigation window, click before the server name to display the remote server information.

2. Click before the SDR to display the sensor groups (e.g. Temperature), then click before a sensor group to display the individual sensors. Select a sensor (e.g. CPU1 Temperature) to display its values in the Detail/SEL window.

The Detail/SEL window displays the sensor data attributes, values, and meanings. From this window, you can adjust the sensor threshold values by clicking the up/down arrow button after each value.

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-9

3. Click More. A sensor window appears displaying additional information on the sensor.

The Information tab displays basic sensor information including the sensor name, current status, current value, and sensor type.

The tab also displays the sensor record ID and SDR version.

4. Click the Settings tab to adjust the sensor threshold values. Click on the up/down arrow button after each threshold value to adjust.

Click OK to close the window.

3-10 Chapter 3: ASUS Remote Console

3.1.4 Displaying FRU information The Field Replaceable Unit (FRU) information provides the manufacturer, product name, and/or serial number of various modules and components installed on the remote server. For example, the FRU feature can display the remote server motherboard name, model, and serial number. You can use this feature when retrieving information on a module or component installed on the remote server.

2. Click before the FRU to display available FRU information, then click before the module/component. Select a module or component from the list to display the FRU information in the Detail/SEL window.

The FRU information feature allows you to obtain component or module information even when the remote server is down or off.

The motherboard information is not included in the FRU information.

To display the FRU information:

1. From the navigation window, click before the server name to open the remote server information.

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-11

3.1.5 Displaying system event logs The System Event Log (SEL) is a non-volatile storage area where all remote server system events are stored for real-time tracking or later retrieval. The ARC application can display system events for efficient remote server monitoring and troubleshooting.

To display the sytem events:

1. From the navigation window, click before the server connection, then click SEL. The status bar displays the progress of the SEL download. When finished, the Detail/SEL window displays the system events in chronological order.

2. Double-click an event to display an Event Information window.

This window displays the sensor type and record ID, event message, current and threshold values, and other system event information.

3. Click OK to close the window.

3-12 Chapter 3: ASUS Remote Console

3.1.6 Using Remote Console The Remote Console feature lets you see the remote server screen (text only) and is useful when you adjust the remote server BIOS settings.

To display the remote server console, press the Remote Console item from the navigation window. The remote server screen appears in the Detail/SEL window.

F1F10 keyboard function keys

Reboot to enter BIOS setup menu

Delete key ARC function keys

(used in combination with other keys)

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-13

3.1.7 Displaying all remote server sensors To display all remote server sensors in graphical format:

1. From the navigation window, click before the server name to open the remote server information.

2. Click All Sensors value. All remote server sensors are displayed on the Information window in graphical format.

The color bar represents the upper/lower threshold values of each sensor. The green pointer indicates the current value of the sensor.

3-14 Chapter 3: ASUS Remote Console

3.1.8 Adjusting the monitoring settings The ARC application allows you to adjust the remote server monitoring settings including SEL polling, SDR reading, and PET.

To adjust the monitoring settings:

1. Click Server on the menu bar, then select General Setting from the drop-down menu. A Server Settings window appears.

2. Click on the up/down arrow button after each setting to adjust the value.

3. Click OK to save your changes and close the window; otherwise, click Cancel to ignore your changes.

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-15

Enabling the Short Message Service (SMS) feature The Short Message Service or SMS feature allows you to receive Platform Event Trap (PET) information on your smart phone (ASUS P505).

You must install Microsoft ActiveSync before you enable the SMS feature. Visit www.microsoft.com to download Microsoft ActiveSync .

To enable the SMS feature:

1. Check the box before the Enable Short Message Service feature.

2. Click Set Phone List.

3. When the SyncSMS mobile phone number setup window opens, key-in the mobile or PDA phone number in the box.

You may click the box before each phone number to disable it.

4. Press OK.

1 2

3-16 Chapter 3: ASUS Remote Console

3.1.9 Controlling the remote server power ARC allows you to power up, power down, or reset the remote server using the power menu.

2. Click Yes when the Confirm power down window appears.

3. The remote server is turned off. Click OK to close the window.

Use the same instructions as reference when powering up or resetting the remote server.

Before turning off or resetting the remote server, make sure that it is not being used and that no application is currently running on it to avoid data loss.

To power down the remote server:

1. Click Control on the menu bar, then select Power down from the drop-down menu.

OR Click the power down button on the

tool bar.

Power Down

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-17

3.1.10 Viewing PET information The Platform Event Trap or PET is an SNMP trap used for system management alerts. When the ARC receives a PET, it displays a pop-up window notifying you of the alert and its source (IP address). Right-click the window to close.

You need to install an SNMP service to the remote server to receive PET information.

To install an SNMP service to the remote service:

1. On the Windows taskbar, click Start > All Programs > Control Panel.

2. Double-click Add/Remove Programs.

3. Double-click Add Windows Components.

3-18 Chapter 3: ASUS Remote Console

4. Double-click Management and Monitoring Tools.

5. Select Simple Network Management Protocol (SNMP).

6. Click OK.

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-19

Important notice for Windows XP (Service Pack 2) users If the local server system is behind a firewall, you must create a UDP port to receive PET information. To create a UDP port: 1. Double-click the My Computer icon from the Windows desktop, then click

the My Network Places link. 2. Click the View network connections link, then select the LAN connection

the remote server system is using. 3. Right-click the LAN connection, then select Properties from the drop-down

menu. 4. Click the Advanced tab, then click the Settings button in the Network

Connection Sharing area. 5. On the Services tab, click the Add button to display a Service Settings

window. 6. Type a name on the Description of service field (i.e. ASUS ARC). 7. Type the IP address of the local/central server, then set the External and

Internal Port number to 162. 8. Select UDP, then click OK. The created service is displayed in the Services

list. Check the box before the service, then click OK.

You must also adjust the Internet Explorer settings to allow active contents to run in the local/central server. To do this: 1. From the Internet Explorer menu, click Tools, then select Internet Options

from the drop-down menu. 2. Click the Advanced tab. 3. Enable the item Allow active content to run in files on My Computer . 4. Click the Apply button, then click OK to close the window.

3-20 Chapter 3: ASUS Remote Console

3.2 ASUS Host Management Controller Setup The ASUS Host Management Controller Setup utility provides precise configuration and basic functions including System Event Log (SEL) generation and System Data Record (SDR) reading in DOS mode.

This utility also supplies configuration sequences for the type of host interface as well as direct real-time monitoring of system information including CPU temperature(s), fan speeds and system voltages.

3.2.1 Installing and launching the ASUS Host Management Controller Setup utility

To install the ASUS Host Management Controller Setup utility:

1. Boot the server in DOS mode using the support CD. 2. At the prompt, type asmc4, then press to display the ASMC4 Utility

Help Menu. The screen appears as shown.

3. The main utility screen appears. Press .

C:\>asmc4

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-21

3.2.2 Command fields The utility menu bar has five commands: Initial, View, Set, Monitor and Help. You can select a command using the left or right arrow button on the keyboard. After selecting a command, use the down arrow key to display available options. Select a command, then press to execute.

3.2.4 View The View command displays the Baseboard Management Controller (BMC) data record including the System Event Log (SEL), the System Data Record (SDR), and general BMC information.

3.2.3 Initial The Initial command allows you to clear the SEL information or exit the utility.

Go to Initial command, then select Clear SEL to empty all System Event Log information for a refresh set of data records. Use the Clear SEL command when creating a new log that begins at an exact time for precise system monitoring.

Select Exit to close the utility and return to the DOS prompt.

Menu options Menu bar

3-22 Chapter 3: ASUS Remote Console

To view the System Data Record (SDR): 1. Select BMC SDR from the View command option, then press .

A complete list of data records appears on the left pane. The right pane displays the sensor data information.

The number on the bottom left of the screen indicates the data record displayed in the right window pane over the total number of sensor data records in the remote host.

2. Use the down arrow key to display the next sensor data record. 3. Press to return to the main screen.

To view the System Event Log (SEL): 1. Select BMC SEL from the View command option, then press . A

complete list of system event records appear on the left pane. The right pane displayes the SEL information.

The number on the left bottom of the window shows the system event displayed in the right window pane over the total number of system events in the remote host.

2. Use the down arrow key to display the next sensor event. 3. Press to return to the main screen.

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-23

To view the BMC information: 1. Select BMC Info from the View command option, then press . A list

of BMC information appears on the left pane. 2. Use the down arrow button to select a BMC information. The BMC

information is displayed in the right pane.

3. Press to return to the main screen.

3-24 Chapter 3: ASUS Remote Console

3.2.5 Set The Set command controls the host interface type and the correct BMC time.

You can select from the following interfaces:

KCS Interface - Keyboard Controller Style SMIC Interface - Server Management Interface Chip BT Interface - Block Transfer PCI Interface - Peripheral Component Interconnect KCS2 Interface - Keyboard Controller 2 Style 3. When finished, press to return to the main screen.

To set the BMC Timer: 1. Select BMC Timer from the Set command option, then press . 2. Set the BMC IPMI timer to the current system time. 3. When finished, press to return to the main screen.

To select the host interface: 1. Select Host Interface from the Set command option, then press .

The screen displays the host interfaces supported by the server management board.

2. Use the down arrow button to select a host interface, then press .

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-25

3.2.6 Monitor The Monitor command displays real-time data on the remote server system and CPU temperatures, voltages, and fan speeds.

To display a remote server information: 1. Select a sensor from the Monitor command options, then press . A

list of server information appears on the left pane. 2. Use the down arrow button to select a monitor information. The selected

monitor information details are displayed in the right pane.

3. Press to return to the main screen.

3-26 Chapter 3: ASUS Remote Console

3.2.7 Help The Help command displays the available utility options, utility version, and copyright information.

4Web-based user interface

This chapter tells you how to use the web-based user interface that the server management board supports.

4-2 Chapter 4: Web-based user interface

4.1 Web-based user interface The web-based user interface allows you to easily monitor the remote servers hardware information including temperatures, fan rotations, voltages, and power. This application also lets you instantly power on/off or reset the remote server.

You should install JRE on remote console first before using web-based management. You can find JRE from the folder JAVA of the ASMB4-iKVM support CD. You can also download JRE from http://java.sun.com/javase/ downloads.

4.1.1 Loging in the utility 1. Ensure that the LAN cable of the computer is connected to the LAN port of

the remote server. 2. Open the web browser and type in the same IP address as the one in the

remote server. 3. The below screen appears. Enter the default user name (admin) and

password (admin). Then click Login.

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 4-3

4.1.2 Using the utility The web-based graphics user interface displays when you login in the utility successfully.

1. Menu bar: Click a menu to display available function lists. 2. Function list: Click each function key to start using its specific functions. 3. Function title: Displays the function title. 4. Section information: Displays the section information. 5. Help menu: Click to display the brief description of the selected function.

3

2

4

1 5

4-4 Chapter 4: Web-based user interface

4.2 System Information This section contains the general information about the system, such as firmware version and detected FRUs.

4.3 Server Health This section contains the data related to the server health, such as the sensor readings and event log. Click each function key to start using its specific functions

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 4-5

4.3.1 Sensor Readings (with Thresholds) The Sensor Readings page displays the system sensor information, including readings and status.

1

2 3

1. Select a sensor type category: Allows you to select the type of sensor readings to be displayed in the list.

2. Refresh: Click to refresh the sensor readings. 3. Show/Hide Thresholds: Click to display/hide the thresholds assigned to

each sensor.

4.3.2 Event Log The Event Log page displays a table of system event log.

1

2

1. Select an event log category: Allows you to select the type of events to be displayed in the list.

2. Refresh: Click to clear the event log.

4-6 Chapter 4: Web-based user interface

4.4 Configuration This section allows you to configure the system settings. Click each function key to start using its specific functions

4.4.1 Alerts The Alert page allows you to configure the alert settings. Click to select the alert item that you want to modify, delete or send a test alert.

1 2 3

1. Modify: Click Modify button to redirect the alert modification page. 2. Send Test Alert: Click to send a test alert to the set-up destination. 3. Delete: Click to delete the selected test alert.

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 4-7

4.4.2 PEF The PEF page allows you to modify the PEF configuration.

1

1. Modify: Click to select the PEF item that you want to modify. Click Modify button to redirect the PEF modification page.

4.4.3 Mouse Mode The Mouse Mode page allows you to select the mouse mode.

1

1. Save: Select the desired mouse mode, and then click Save to apply the setting.

4-8 Chapter 4: Web-based user interface

4.4.4 Network The Network page allows you to configure the network settings.

1. MAC Address: Select whether to obtain the IP address automatically or manually configure one.

2. IP Address/Subnet Mask/Default Gateway: If you configure a static IP, enter the requested address, subnet mask and gateway in the given field.

3. Save: Click to apply the settings.

1 2

3

4.4.5 SMTP The SMTP page allows you to configure SMTP mail server. Enter the IP address of the mail server, and then click Save to apply the settings.

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 4-9

4.4.6 SSL The SSL page displays the default certificate and private key, and allows you to upload the new SSL certificate. Click Browse to navigate the available certificate, and the click Upload to upload a new SSL certificate.

4.4.7 Users The Users page allows you to configure the user settings and its privilege for this server.

1. Add User: Select an empty item, and then click this button to add a new user. The user name should be at least 4 characters; the password should be at least 8 characters.

2. Modify User: Select a user in the list, and then click this button to modify the settings.

3. Delete User: Select a user in the list, and then click this button to delete the user.

1 2 3

4-10 Chapter 4: Web-based user interface

4.4.8 Configure LDAP The Configure LDAP page allows you to authenticate and access the LDAP server. Complete the settings in the given field, and then click Save to apply the settings.

4.4.9 Date/Time/NTP Settings The Date/Time/NTP Settings page allows you to set up specific date/time or synchronize the date/time with NTP server.

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 4-11

4.5 Remote Control This section allows you to perform remote operations on the server. Click each function key to start using its specific functions

4.5.1 Console Redirection The Console Redirection page allows you to launch the redirection console and manage the server remotely. Click Java Console to open the java redirection window.

4-12 Chapter 4: Web-based user interface

4.5.2 Server Power Control The Server Power Control page displays the current server power status and allows you to change the current settings. Select the desired option, and then click Perform Action to execute the selected action.

4.5.3 Capture Screen Video The Capture Screen Video page allows you to view the latest redirection screenshot. Click Capture Screen to view the screen capture data.

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 4-13

4.5.4 Chassis Identify Command The Chassis Identify Command page allows you to perform a chassis identify command control operation. Enter identify interval in seconds, and then click Perform Action to start the command.

4.6 Maintenance This section allows you to perform the firmware update for the remote server. Click Enter Update Mode to open the firmware update window.

4-14 Chapter 4: Web-based user interface

4.7 Languages This section allows you to select the language for the web-based application. Select the available language from the list, and then click Apply to perform the setting.

AAppendix: Reference information

The Appendix shows the location of the LAN ports for server management and BMC connector on server motherboards. This section also presents common problems that you may encounter when installing or using the server management board.

A-2 Appendix: Reference information

A.1 BMC connector The ASUS server motherboards that support the ASMB4-iKVM/ASMB4-SOL PLUS comes with a Baseboard Management Controller (BMC) connector.

Refer to the illustration below to locate the BMC connector on different server motherboards.

ASUS ASMB4-iKVM/ASMB4-SOL PLUS A-3

A.2 LAN ports for server management The ASUS server motherboards that support the ASMB4-iKVM/ASMB4-SOL PLUS comes with three LAN (RJ-45) ports: one for network connection and the other two for server management. For easy identification, the LAN ports for server management are LAN1 and LAN3 ports. You must use the LAN1 and LAN3 ports for server management to connect the remote server to the local/central host (direct LAN connection) or to the network hub or router.

Refer to the illustration below to identify the LAN1 and LAN3 ports for server management on some server motherboards.

You may refer to motherboard manual for the location of LAN1 and LAN3 ports.

LAN3

LAN1

A-4 Appendix: Reference information

A.3 Troubleshooting

Problem Solution

The local/central server cannot connect to the ASMB4-iKVM/ASMB4-SOL PLUS board

1. Check if the LAN cable is connected to the LAN port.

2. Make sure that the IP address of both the remote and local/central servers are on the same subnet. (Refer to chapter 2 for details.) Try ping xx.xx.xx.xx (remote server ip) on local/central server and make sure remote server could reply the ping request.

3. Check if the IP source is set to [DHCP]. When set to [DHCP], youll not be able to configure the IP address.

All the SEL (System Event Log) cannot be displayed

The maximum SEL number is 900 events.

The date/time shown in SEL (System Event Log) screen is incorrect

Refer to section 4.4.9 to check if the time zone is set up correctly.

ASMB4-iKVM/ASMB4-SOL PLUS has network connection problems in Firewall environment

Ask MIS to add the following port numbers in Firewall: 5123 (virtual floppy) (TCP) 5120 (virtual CDROM) (TCP) 623 (IPMI) (TCP & UDP) 80 (HTTP) (TCP) 7578 (iKVM) (TCP) 443 (HTTPs) (TCP) 161 (SNMP) (UDP)

The Java redirection screen cannot be displayed normally

Click Refresh Page button to refresh the redirection screen.

This troubleshooting guide provides answers to some common problems that you may encounter while installing and/or using ASUS ASMB4-iKVM/ASMB4-SOL PLUS. These problems require simple troubleshooting that you can perform by yourself. Contact the Technical Support if you encounter problems not mentioned in this section.

ASUS ASMB4-iKVM/ASMB4-SOL PLUS A-5

A.4 BMC Sensor Codes Table

Category 1: Memory related

Sensor No.

Sensor Name Sensor Type Sensor Type code

Sensor Value or Event Type Event Data 3

0xD1

CPU1_ECC1

Memory ECC Sensor

0x0C

Discrete(0x6F) 0x01: Correctable ECC 0x02: Uncorrectable ECC 0x40: Presence detected

0x00: DIMM_A1, 0x01: DIMM_A2, 0x02: DIMM_A3, 0x03:DIMM_A4, 0x04: DIMM_B1, 0x05: DIMM_B2, 0x06: DIMM_B3, 0x07: DIMM_B4, 0x08: DIMM_C1, 0x09: DIMM_C2, 0x0A: DIMM_C3, 0x0B: DIMM_C4, 0x0C: DIMM_D1, 0x0D: DIMM_D2, 0x0E: DIMM_D3, 0x0F: DIMM_D4

0xD2

CPU1_ECC2

OEM Memory ECC Sensor (For Intel DP platform only -- ASUS Z8 series server MB; -E6 server system)

0xC1

Discrete(0x6F) 0x01: Read ECC error 0x02: ECC Error occurred on a scrub 0x04: Write Parity Error 0x08: Error in Redundant memory 0x10: Sparing Error 0x20: Memory access out of Range 0x40: Address Parity Error 0x80: Byte Enable Parity

0x00: DIMM_A1, 0x01: DIMM_A2, 0x02: DIMM_A3, 0x03:DIMM_A4, 0x04: DIMM_B1, 0x05: DIMM_B2, 0x06: DIMM_B3, 0x07: DIMM_B4, 0x08: DIMM_C1, 0x09: DIMM_C2, 0x0A: DIMM_C3, 0x0B: DIMM_C4, 0x0C: DIMM_D1, 0x0D: DIMM_D2, 0x0E: DIMM_D3, 0x0F: DIMM_D4

0xD3

CPU2_ECC1

Memory ECC Sensor

0x0C

Discrete(0x6F) 0x01: Correctable ECC 0x02: Uncorrectable ECC 0x40: Presence detected

0x00: DIMM_D1, 0x01: DIMM_D2, 0x02: DIMM_D3, 0x03: DIMM_D4, 0x04: DIMM_E1, 0x05:DIMM_E2, 0x06: DIMM_E3, 0x07: DIMM_E4, 0x08: DIMM_F1, 0x09: DIMM_F2, 0x0A: DIMM_F3, 0x0B: DIMM_F4, 0x0C: DIMM_G1, 0x0D: DIMM_G2, 0x0E: DIMM_G3, 0x0F: DMM_G4, 0x10: DIMM_H1, 0x11: DIMM_H2, 0x12: DIMM_H3, 0x13: DIMM_H4, 0x14: DIMM_C1, 0x15: DIMM_C2, 0x16: DIMM_C3, 0x17: DIMM_C4

0xD4 CPU2_ECC2 OEM Memory ECC Sensor (For Intel DP platform only -- ASUS Z8 series server MB; -E6 server system)

0xC1 Discrete(0x6F) 0x01: Read ECC error 0x02: ECC Error occurred on a scrub 0x04: Write Parity Error 0x08: Error in Redundant memory 0x10: Sparing Error 0x20: Memory access out of Range 0x40: Address Parity Error 0x80: Byte Enable Parity

0x00: DIMM_D1, 0x01: DIMM_D2, 0x02: DIMM_D3, 0x03: DIMM_D4, 0x04: DIMM_E1, 0x05:DIMM_E2, 0x06: DIMM_E3, 0x07: DIMM_E4, 0x08: DIMM_F1, 0x09: DIMM_F2, 0x0A: DIMM_F3, 0x0B: DIMM_F4, 0x0C: DIMM_G1, 0x0D: DIMM_G2, 0x0E: DIMM_G3, 0x0F: DMM_G4, 0x10: DIMM_H1, 0x11: DIMM_H2, 0x12: DIMM_H3, 0x13: DIMM_H4, 0x14: DIMM_C1, 0x15: DIMM_C2, 0x16: DIMM_C3, 0x17: DIMM_C4

A-6 Appendix: Reference information

Category 2: HDD / Backplane related

Sensor No. Sensor Name Sensor Type Sensor Type Code Sensor Value or Event Type

0x68

Backplane1 HD1

Drive Slot

0x0D

Discrete(0x6F) 0x01: Drive Presence 0x02: Drive Fault 0x80: Rebuild

0x69

Backplane1 HD2

Drive Slot

0x0D

Discrete(0x6F) 0x01: Drive Presence 0x02: Drive Fault 0x80: Rebuild

0x6A

Backplane1 HD3

Drive Slot

0x0D

Discrete(0x6F) 0x01: Drive Presence 0x02: Drive Fault 0x80: Rebuild

0x6B

Backplane1 HD4

Drive Slot

0x0D

Discrete(0x6F) 0x01: Drive Presence 0x02: Drive Fault 0x80: Rebuild

0x6C

Backplane1 HD5

Drive Slot

0x0D

Discrete(0x6F) 0x01: Drive Presence 0x02: Drive Fault 0x80: Rebuild

0x6D

Backplane1 HD6

Drive Slot

0x0D

Discrete(0x6F) 0x01: Drive Presence 0x02: Drive Fault 0x80: Rebuild

0x6E

Backplane1 HD7

Drive Slot

0x0D

Discrete(0x6F) 0x01: Drive Presence 0x02: Drive Fault 0x80: Rebuild

0x6F

Backplane1 HD8

Drive Slot

0x0D

Discrete(0x6F) 0x01: Drive Presence 0x02: Drive Fault 0x80: Rebuild

0x78

Backplane2 HD1

Drive Slot

0x0D

Discrete(0x6F) 0x01: Drive Presence 0x02: Drive Fault 0x80: Rebuild

0x79

Backplane2 HD2

Drive Slot

0x0D

Discrete(0x6F) 0x01: Drive Presence 0x02: Drive Fault 0x80: Rebuild

0x7A

Backplane2 HD3

Drive Slot

0x0D

Discrete(0x6F) 0x01: Drive Presence 0x02: Drive Fault 0x80: Rebuild

0x7B

Backplane2 HD4

Drive Slot

0x0D

Discrete(0x6F) 0x01: Drive Presence 0x02: Drive Fault 0x80: Rebuild

0x7C

Backplane2 HD5

Drive Slot

0x0D

Discrete(0x6F) 0x01: Drive Presence 0x02: Drive Fault 0x80: Rebuild

0x7D

Backplane2 HD6

Drive Slot

0x0D

Discrete(0x6F) 0x01: Drive Presence 0x02: Drive Fault 0x80: Rebuild

0x7E

Backplane2 HD7

Drive Slot

0x0D

Discrete(0x6F) 0x01: Drive Presence 0x02: Drive Fault 0x80: Rebuild

0x7F

Backplane2 HD8

Drive Slot

0x0D

Discrete(0x6F) 0x01: Drive Presence 0x02: Drive Fault 0x80: Rebuild

ASUS ASMB4-iKVM/ASMB4-SOL PLUS A-7

Category 3: Power Supply related

Sensor No. Sensor Name Sensor Type Sensor Type Code Sensor Value or Event Type

0x81

PSU1 Temp

Temperature

0x01

Threshold(0x01) Upper Non-Critical - going high Upper Critital - going high

0x82

PSU1 Fan1

FAN

0x04

Threshold(0x01) Lower Non-critical - going low Lower Critital - going low

0x83

PSU1 Fan2

FAN

0x04

Threshold(0x01) Lower Non-critical - going low Lower Critital - going low

0x92

PSU1 Over Temp

Temperature

0x01

Discrete(0x07) 0x01: Transition to OK 0x10: Transition to Non-Critical from more severe 0x40: Transition to Non-Recoverable

0x93

PSU1 FAN Low

FAN

0x04

Discrete(0x07) 0x01: Transition to OK 0x10: Transition to Non-Critical from more severe

0x94

PSU1 AC

Power Supply

0x08

Discrete(0x6F) 0x01: Presence Detected 0x08: Power Supply input lost (AC/DC)

0x95

PSU1 Slow FAN1

FAN

0x04

Discrete(0x07) 0x01: Transition to OK 0x10: Transition to Non-Critical from more severe 0x40: Transition to Non-Recoverable

0x96

PSU1 Slow FAN2

FAN

0x04

Discrete(0x07) 0x01: Transition to OK 0x10: Transition to Non-Critical from more severe 0x40: Transition to Non-Recoverable

0x97

PSU1 PWR Detect

Power Supply

0x08

Discrete(0x6F) 0x01: Presence Detected 0x02: Power Supply Failure Detected

0x84

PSU2 Temp

Temperature

0x01

Threshold(0x01) Upper Non-Critical - going high Upper Critital - going high

0x85

PSU2 Fan1

FAN

0x04

Threshold(0x01) Lower Non-critical - going low Lower Critital - going low

0x86

PSU2 Fan2

FAN

0x04

Threshold(0x01) Lower Non-critical - going low Lower Critital - going low

0x9A

PSU2 Over Temp

Temperature

0x01

Discrete(0x07) 0x01: Transition to OK 0x10: Transition to Non-Critical from more severe 0x40: Transition to Non-Recoverable

0x9B

PSU2 FAN Low

FAN

0x04

Discrete(0x07) 0x01: Transition to OK 0x10: Transition to Non-Critical from more severe

0x9C

PSU2 AC Lost

Power Supply

0x08

Discrete(0x6F) 0x01: Presence Detected 0x08: Power Supply input lost (AC/DC)

0x9D

PSU2 Slow FAN1

FAN

0x04

Discrete(0x07) 0x01: Transition to OK 0x10: Transition to Non-Critical from more severe 0x40: Transition to Non-Recoverable

0x9E

PSU2 Slow FAN2

FAN

0x04

Discrete(0x07) 0x01: Transition to OK 0x10: Transition to Non-Critical from more severe 0x40: Transition to Non-Recoverable

0x9F

PSU2 PWR Detect

Power Supply

0x08

Discrete(0x6F) 0x01: Presence Detected 0x02: Power Supply Failure Detected

A-8 Appendix: Reference information

Category 4: Hardware Monitor / System Sensor related

Sensor No. Sensor Name Sensor Type Sensor Type Code Sensor Value or Event Type

0x31

CPU1 Temperature

Temperature

0x01

Threshold(0x01) Upper Non-critical - going high Upper Critical - going high

0x32

CPU2 Temperature

Temperature

0x01

Threshold(0x01) Upper Non-critical - going high Upper Critical - going high

0xCC

TR1 Temperature

Temperature

0x01

Threshold(0x01) Upper Non-critical - going high Upper Critical - going high

0xCD

TR2 Temperature

Temperature

0x01

Threshold(0x01) Upper Non-critical - going high Upper Critical - going high

0x34

VCORE1

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x35

VCORE2

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x36

+3.3V

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x37

+5V

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x38

+12V

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x39

+1.5V_ICH (For Intel DP platform only -- ASUS Z8 series server MB; -E6 server system)

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x3A

+1.1V_IOH (For Intel DP platform only -- ASUS Z8 series server MB; -E6 server system)

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x3B

+5VSB

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x3C

VBAT

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x3D

P1VTT (For Intel DP platform only -- ASUS Z8 series server MB; -E6 server system)

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x3E

+1.5V_P1DDR3 (For Intel platform only -- ASUS Z8 series server MB; -E6 server system)

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

ASUS ASMB4-iKVM/ASMB4-SOL PLUS A-9

0x3F

P2VTT (For Intel DP platform only -- ASUS Z8 series server MB; -E6 server system)

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x40

+3.3VSB

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x41

+1.5V_P2DDR3 (For Intel DP platform only -- ASUS Z8 series server MB; -E6 server system)

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x42

P1DDR3 (For AMD platform only)

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x42

+1.5V (For Intel UP platform only)

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x43

P2DDR3 (For AMD platform only)

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x44

P1_+1.2V (For AMD platform only)

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x45

P2_+1.2V (For AMD platform only)

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x46

P1_VDDNB (For AMD platform only)

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x47

+1.8V (For AMD platform only)

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x48

+1.2V (For AMD platform only)

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x49

+1.1V (For AMD platform only)

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0x4A

VTT (For AMD platform only)

Voltage

0x02

Threshold(0x01) Lower Non-critical - going low Lower Critical - going low Upper Non-critical - going high Upper Critical - going high

0xA0

CPU_FAN1

FAN

0x04

Threshold(0x01) Lower Non-critical - going low Lower Critital - going low

0xA1

CPU_FAN2

FAN

0x04

Threshold(0x01) Lower Non-critical - going low Lower Critital - going low

A-10 Appendix: Reference information

0xA2

FRNT_FAN1

FAN

0x04

Threshold(0x01) Lower Non-critical - going low Lower Critital - going low

0xA3

FRNT_FAN2

FAN

0x04

Threshold(0x01) Lower Non-critical - going low Lower Critital - going low

0xA4

FRNT_FAN3

FAN

0x04

Threshold(0x01) Lower Non-critical - going low Lower Critital - going low

0xA5

FRNT_FAN4

FAN

0x04

Threshold(0x01) Lower Non-critical - going low Lower Critital - going low

0xA6

REAR_FAN1

FAN

0x04

Threshold(0x01) Lower Non-critical - going low Lower Critital - going low

0xA7

REAR_FAN2

FAN

0x04

Threshold(0x01) Lower Non-critical - going low Lower Critital - going low

0xA8

FRNT_FAN5

FAN

0x04

Threshold(0x01) Lower Non-critical - going low Lower Critital - going low

0xA9

FRNT_FAN6

FAN

0x04

Threshold(0x01) Lower Non-critical - going low Lower Critital - going low

0xAA

FRNT_FAN7

FAN

0x04

Threshold(0x01) Lower Non-critical - going low Lower Critital - going low

0x4F

Chassis Intrusion

Physical Security (Chassis Intrusion)

0x05

Discrete(0x6F) 0x01: General Chassis Intrusion 0x02: Drive Ba

Manualsnet FAQs

If you want to find out how the ASMB4-iKVM ASUS works, you can view and download the ASUS ASMB4-iKVM Server User Manual on the Manualsnet website.

Yes, we have the User Manual for ASUS ASMB4-iKVM as well as other ASUS manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User Manual should include all the details that are needed to use a ASUS ASMB4-iKVM. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the ASUS ASMB4-iKVM Server User Manual is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This ASUS ASMB4-iKVM Server User Manual consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download ASUS ASMB4-iKVM Server User Manual free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print ASUS ASMB4-iKVM Server User Manual, simply download the document to your computer. Once downloaded, open the PDF file and print the ASUS ASMB4-iKVM Server User Manual as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.