Contents

Apple EMULEX Model 375 User's Guide PDF

1 of 77
1 of 77

Summary of Content for Apple EMULEX Model 375 User's Guide PDF

U se

rs G

ui de

Emulex Model 375 SAN Storage Switch For Apple Computer Users

00041392-002 Rev. B

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE

EMULEX CORPORATION I

PART NUMBER 00041392-002 REV. B

2004 Emulex Corporation. All rights reserved.

Emulex and Vixel are registered trademarks, and InSpeed and FibreSpy are trademarks, of Emulex Corporation. All other brand or product names referenced herein are trademarks or registered trademarks of their respective companies or organizations.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE TABLE OF CONTENTS

EMULEX CORPORATION II

PART NUMBER 00041392-002 REV. B

Table of Contents

Table of Contents ...................................................................................ii

Chapter 1: Introduction .......................................................................................1

Chapter 2: Switch Installation ............................................................................6

Chapter 3: Switch Management .......................................................................15

Chapter 4: Technical Reference .......................................................................59

Appendixes........................................................................................... 63

Appendix A: Specifications ............................................................................... 64

Appendix B: CLI Quick Reference .................................................................... 65

Appendix C: Event Messages ........................................................................... 68

Appendix D: AL_PA Cross References ............................................................ 70

Appendix E: Glossary ........................................................................................ 71

Index .................................................................................................... 72

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 1: INTRODUCTION

EMULEX CORPORATION 1 PART NUMBER 00041392-002 REV. B

CHAPTER 1 INTRODUCTION

This guide is designed to provide users with the necessary information to install and manage the Emulex Model 375 SAN Storage Switch for use in Fibre Channel applications in typical entry-level Storage Area Networks (SANs).

OVERVIEW

The Emulex Model 375 SAN Storage Switch is designed for entry-level Storage Area Networks (SANs), which provide the following advantages over direct attached storage:

Greater application availability

Higher performance between servers and storage devices

Improved storage asset utilization

Lower storage management and support costs

Incremental scalability to keep up with difficult to estimate storage growth

This switch is ideal for storage pooling and consolidation, high-performance shared tape library backup and recovery, server clustering, and streaming rich media applications.

Enclosed in a 1U, full-rack form factor enclosure, the switch is built around the InSpeed SOC 320 and is controlled by firmware loaded into the on-board Flash.

The switch is designed as a central interconnect following the ANSI FC-AL standard. Devices are connected to the switch through Small Form-factor Pluggable (SFP) transceivers and cables. Each attached node has 1 or 2 Gigabits per second (Gb/s) of Fibre Channel bandwidth. The switch operates at full switching bandwidth that reaches speeds of 4 Gb/s per port and up to 80 Gb/s of aggregate bandwidth.

Complete switch configuration and management is available through the intuitive, graphical-based Web Manager interface. A variety of network configurations are easily established using the switchs Port Smart Settings, One-Step Zoning, Automatic Trunking, and Load Balancing features. In addition, the switch features granular change notification management, retained system configuration parameters, and a Command Line Interface (CLI) for advanced users.

Overview......................................................................1

Features ......................................................................2

InSpeed Technology .................................................2

Switch Applications ......................................................3

Note: Important safety, electromagnetic compatibility, and regulatory information is contained in the Safety & Regulatory Guide. The installation and use of this product must be in accordance with the information provided in that guide.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 1: INTRODUCTION

EMULEX CORPORATION 2 PART NUMBER 00041392-002 REV. B

FEATURES

The Emulex Model 375 SAN Storage Switch has the following features:

High Performance Fibre Channel Switching:

Wire speed non-blocking Crossbar switch core

Single 20-port InSpeed SOC 320 ASIC with embedded SERDES

Multiple simultaneous conversations between ports

Traffic routed directly to destination ports

2 Gb/s or 1 Gb/s performance across all ports

Aggregate bandwidth of 80 Gb/s

Supports cascades up to 3 switches and up to 126 host and storage devices

No complex fabric services or buffers

Effortlessly connects to any vendors fabric

Patent-pending technology:

Fairness and Prioritizationensures that devices all have guaranteed access, or explicitly have prioritized access, over all other devices in a system.

StealthTM Intelligent Change Managerdelivers maximum stability through automatic elimination of state and change notification system disruptions and unprecedented control of disruptive events.

Automatic Trunkingenables fully-multiplied throughput and bandwidth, failover pathing, and dynamic load balancing and device prioritization.

Advanced diagnostics, performance monitoring, and fault isolation including continuous switch and port monitoring and automatic bypass of problematic or unused ports.

Port Smart Settings, which are predefined port-level configurations that optimize switch performance and stability.

One-Step Zoning, including overlapping/non-overlapping zones with port or AL_PA-based zoning.

Switch management using the embedded http-based Web server, Command Line Interface (CLI), or Simple Network Management Protocol (SNMP).

Full-rack, 1U size for easy installation (optional 19" rack-mounting kits available).

Redundant fans and two hot-swappable, auto-sensing, load sharing, universal power supplies for high availability.

Fibre Channel ANSI Standards Compliance

INSPEED TECHNOLOGY

InSpeed technology is an advanced switching architecture that couples a non-blocking crossbar switch with a unique switch port logic and per-port SERDES. This results in the industrys highest density Fibre Channel switch on a chip (SOC). The port logic is based on Fibre Channel-Arbitrated Loop (FC-AL), an ANSI standard (X3T11) designed to provide shared bandwidth over low-cost media.

This architecture enables the switchs router to send data directly from one port to another, allowing for multiple, simultaneous conversations between portseffectively multiplying bandwidth. InSpeed provides the same performance as complex fabric switches that support FC-SW2. InSpeed can even exceed fabric switch performance in entry-level SAN environments, where the overhead associated with longer name addressing and services is not beneficial.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 1: INTRODUCTION

EMULEX CORPORATION 3 PART NUMBER 00041392-002 REV. B

SWITCH APPLICATIONS

The Emulex Model 375 SAN Storage Switch is ideal for consolidation and shared storage pooling, high- performance shared tape library backup and recovery, server clustering, and streaming rich media applications. The following sections provide examples of these applications.

Storage Consolidation and Shared Storage Pooling

In this configuration, the switch enables multiple hosts to share single or multiple storage systems. This application replaces direct-attached configurations that require multiple storage systems to be attached to separate servers, which often results in difficult to manage multiple systems and trapped, unused storage islands (storage cannot be shared with other servers).

Benefits include:

Improved incremental scalabilityconnect up to 20 hosts and/or other storage devices, including tape libraries, to a single switch.

Lower storage management support costs.

Improved capacity utilization that enables effective use of both servers and storage.

For larger system environments, multiple switches can be connected and Automatic Trunking can be used to keep performance and availability at high levels. As a best practice when using multiple switches, connect servers and their related storage devices through the same switch to optimize performance.

Figure 1-1: Before storage consolidation... Figure 1-1: and after storage consolidation.

Figure 1-2: Multiple switch storage consolidation diagram

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 1: INTRODUCTION

EMULEX CORPORATION 4 PART NUMBER 00041392-002 REV. B

Figure 1-2 depicts a sample multiple switch storage consolidation configuration in which multiple servers communicate with storage devices and zoning is incorporated. The zoning in Figure 1-2 might be set up to configure a multiple operating system environment. For example, Zone 1 might be Windows-based, Zone 2 might be Linux-based, and Zone 3 might be Unix-based. Zoning can also be used to improve security by masking storage devices or files. For example, a finance department could secure financial files from viewing by the engineering department, which in turn could secure engineering files from viewing by the finance department.

Tape Library Consolidation

Another switch application is the consolidation of multiple tape libraries attached to individual servers into a single library for all servers for backup and restore purposes.

Benefits include:

Improved cost effectiveness.

Improved availability for performing system backups:

Off-LAN System Backups often reduce the amount of time it takes backups (and recovery) to occur because SANs run at higher performance bandwidth than LANs.

Server-less backups enable applications to remain fully active during backup and recovery processes, when combined with the appropriate backup software solution.

Figure 1-3 depicts a sample tape library consolidation configuration.

Figure 1-3: Before consolidation, backup and restore data must travel on the LAN, congesting traffic and operating at slow speeds.

Figure 1-3: After consolidation, backup and restore data travels on the high speed SAN separate from LAN traffic.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 1: INTRODUCTION

EMULEX CORPORATION 5 PART NUMBER 00041392-002 REV. B

Rich Media

For rich media applications, the switch provides improved storage and file sharing from a single storage pool for multiple workstations.

Figure 1-4 depicts a sample rich media configuration.

Server Clustering

In this configuration, the switch helps deliver improved application availability when combined with a server clustering software solution, like Microsoft Cluster Server or Veritas Cluster Server. This prevents system downtime in case of failure to one of the application servers.

Figure 1-5 depicts a sample server clustering configuration.

Figure 1-4: Rich media diagram

Figure 1-5: Server clustering diagram

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 2: SWITCH INSTALLATION

EMULEX CORPORATION 6 PART NUMBER 00041392-002 REV. B

CHAPTER 2 SWITCH INSTALLATION

INSTALLATION PREPARATION

After receiving the switch, perform the following steps to ensure that the switch and other contents arrived safely.

To unpack the switch:

1. Inspect the outer shipping container for any damage that may have occurred in shipping. Report any sign of damage to the appropriate shipping agency.

2. Remove the switch and cables from the shipping container; save the shipping container, foam, and antistatic bagsreturning the switch in any other container is not advised.

Make sure the following parts are included:

Switch unit

RS-232 null-modem serial cable

Power cables (2)

Self-adhesive pads (4)

Retention clips (2), screws (4), and washers (4) for securing the power cords to the switch.

Quick Install Card

Product Release Notes

Safety and Regulatory Guide

Additional documentation, including warranty information and the End User License Agreement.

3. Inspect the switch thoroughly. (If any signs of damage are seen, notify a sales representative and/or the shipping agency.)

Installation Preparation ................................................6

Switch Installation ........................................................7

Switch LEDs ................................................................9

SFP Compatibility ......................................................12

Booting the Switch and SAN ......................................13

Power Supply/Fan Module Replacement ...................14

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 2: SWITCH INSTALLATION

EMULEX CORPORATION 7 PART NUMBER 00041392-002 REV. B

SWITCH INSTALLATION

The switch can be installed in a rack or placed on a desktop.

Rack Installation

Installing the switch in an equipment rack requires an optional rack mount kit (sold separately). There are two kit variations currently available:

24-inch Full Rack Mount Kit (Part Number 00651382), which supports equipment rack depths from 24 to 29.75 inches.

30-inch Full Rack Mount Kit (Part Number 00651383), which supports equipment rack depths from 30 to 36 inches.

The rack mount kit includes all the necessary hardware and installation instructions for properly installing a switch into an equipment rack. Contact a sales representative for more information or assistance in purchasing a kit.

UL Guidelines for Mounting Equipment in a Rack

When installing equipment in a rack, give careful consideration to the following factors:

The operating ambient temperature of rack-mounted equipment must not exceed the maximum rated ambient temperature, which is indicated in this installation guide. (See Operating Conditions on page 64.)

The air flow clearances specified in this installation guide must be maintained within the rack. (See Operating Conditions on page 64.)

The AC supply circuit for rack-mounted equipment must be capable of supplying the total current specified on all the labels of the rack-mounted equipment.

All AC power supply connections must be properly earthed. To ensure the integrity of the earth connection, special attention must be given to connections that are not directly connected to the branch circuit (for example, power strips).

The rack-mounting hardware has been carefully selected to properly support the equipment. Any alternate rack-mounting hardware must provide equal or superior support.

Desktop Installation

To place the switch on a desktop:

1. Turn the switch upside down so the case bottom is facing up.

2. Install a self-adhesive pad (included) on each corner of the switch bottom approximately 1 inch from each side (prevents surface damage).

3. Turn the switch right-side up so the case bottom is facing down and place the switch on a stable table or platform.

For information on environmental requirements, see Operating Conditions on page 64.

Note: Important safety, electromagnetic compatibility, and regulatory information is contained in the Safety & Regulatory Guide. The installation and use of this product must be in accordance with the information given in that guide.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 2: SWITCH INSTALLATION

EMULEX CORPORATION 8 PART NUMBER 00041392-002 REV. B

Installing the Retention Clips (optional)

The switch ships with two, optional retention clips to secure the power cords in each power supply/fan modules power receptacle. Screws (4) and washers (4) are provided for the clips.

To install the retention clip:

1. Secure the retention clip to the switch by aligning the retention clip with the two screw holes located to the left and the right of the modules power receptacle. The retention clip mounting loops should be facing downward.

2. Place the washer on the screw prior to inserting the screw through the retention clips mounting loop.

3. Using a screwdriver, tighten the screws to secure the retention clip to the power supply/fan module.

To insert the power cord with the retention clip in place:

1. Insert the power cord plug into the modules power receptacle. The plug must initially be inserted into the receptacle at an angle to avoid the retention clip.

2. Once the power cord plug is firmly inserted in the modules power receptacle, the retention clip fastens over the end of the power cord plug to secure it in the power receptacle.

To remove the power cord with the retention clip in place:

Press down on the retention clip while removing the power cord from the modules power receptacle.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 2: SWITCH INSTALLATION

EMULEX CORPORATION 9 PART NUMBER 00041392-002 REV. B

SWITCH LEDS

The switch incorporates four sets of Light-Emitting Diodes (LEDs) to indicate ethernet, switch, port, and power supply/fan module status:

1. Ethernet LEDs two separate LEDs indicating the network connection status.

2. System LEDs four separate LEDs indicating the switchs status.

3. Port LEDs two LEDs per port indicating the ports status.

4. Power Supply/Fan LED a separate LED for each power supply/fan module indicating the power supply/fan modules status.

Ethernet LEDs

The Ethernet LEDs indicate the network connection status:

Ethernet LEDs Indication

Ethernet Activity (green LED)

When flashing, the ethernet port is receiving data. When flashing rapidly, the traffic level is high.

Ethernet Link (green LED)

When lit, the switch is connected to an operational ethernet.

Figure 2-1: Switch View Depicting Ethernet, Port, and System LEDs

Port LEDs

Ethernet LEDs

System LEDs

Figure 2-2: Switch View Depicting Power Supply/Fan LED

Power Supply/Fan LED Power Supply/Fan LED

Figure 2-3: Ethernet LEDs

Ethernet Activity Ethernet Link

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 2: SWITCH INSTALLATION

EMULEX CORPORATION 10 PART NUMBER 00041392-002 REV. B

System LEDs

The System LEDs indicate the switchs status, independent of the port LEDs.

Port LEDs

The Port LEDs indicate the ports status. Each port has two LEDs:

SFP Status LED

Port Bypassed LED

System LEDs Indication

Fault (yellow LED)

When lit, one or more of the ports has failed or the internal temperature has exceeded acceptable levels.

When flashing, all ports are operational but another error has occurred. Errors appear in an event log. The level of error severity that will cause flashing to start can be controlled using the config sys fault command in the CLI. The default is level 3, Critical.

Note: Whether lit or flashing, the switch will continue to operate. Switch functionality may be impaired depending on the event that triggered the Fault LED. Regardless of the cause, the switch requires immediate attention.

Power (green LED)

When lit, the switch is plugged in and the internal power supplies are functional.

2 Gb/s (green LED)

When lit, the switch is set to operate at a speed of 2 Gb/s. When off, the switch is set to 1 Gb/s.

Switch Operational (green LED)

When lit, indicates that the switch has completed initialization for ports with inserted SFPs and that the switch is operational.

When flashing, the switch has been configured for multiple zones, and one or more zones are up with at least one zone down.

If no zones (excluding hard zones) are operational, the LED turns off.

SFP Status LED

(green LED)

Port Bypassed LED

(yellow LED) Indication

Off Off Normal port operational status when an SFP is not installed.

Off On or Flashing The port is bypassed due to a faulty or improperly seated SFP. After fixing this problem, power may need to be cycled before the LED indication will change.

Figure 2-4: System LEDs

Power

Switch Operational

Fault

2 Gb/s

Figure 2-5: Port LEDs

SFP Status Port Bypassed

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 2: SWITCH INSTALLATION

EMULEX CORPORATION 11 PART NUMBER 00041392-002 REV. B

Power Supply/Fan Module LED

The switch uses two power supply/fan modules to guarantee high availability with failover. Each power supply has a separate LED to indicate its condition.

When a power supply or fan fault occurs, the switch will continue to operate normally as long as the faulty power supply/fan module remains installed in the switch and there are at least two fans operational in each module. If the power supply/fan module is removed from the switch, the switch will continue to operate normally for approximately 20-30 minutes. However, to guarantee continued operation, the malfunctioning module should be immediately replaced to maintain high availability.

Flashing Off Activity. Data is being transferred between the port and device.

On Off Normal operation but no activity. Port and device are fully operational.

On Flashing Manually bypassed. A port can be manually bypassed using the Web Managers Bypass Port feature.

On On Bypassed. SFP is installed but the port is not receiving a valid signal or is receiving an F8 Failure notification from the attached device.

Flashing Flashing Beaconing. This is set manually using the Web Manager or CLI.

Power Supply/Fan Module LED (green LED)

Indication

On No faults exist and AC power is supplied to the module.

Off A power supply or fan fault has occurred in the module.

Note: Keeping spare power supply/fan modules (Part Number 601319) in stock is highly recommended. Contact a sales representative for further information.

SFP Status LED

(green LED)

Port Bypassed LED

(yellow LED) Indication

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 2: SWITCH INSTALLATION

EMULEX CORPORATION 12 PART NUMBER 00041392-002 REV. B

SFP COMPATIBILITY

SFPs are hot-pluggable into the switch, which allows host computers, servers, and storage devices to be added dynamically without requiring power removal from the switch or any connected devices.

The switch supports Small Form-Factor Pluggable (SFP) modules that comply with the SFP specification as produced by the MSA consortium and have passed Emulexs qualification testing.

The following manufacturers of 1-2Gb optical, shortwave SFPs are recommended:

Finisar

JDS Uniphase

Contact a customer service representative to request the certified part numbers for these vendors.

Installing an SFP

If the Change Notification on Insertion policy is enabled, plugging an SFP into the switch will automatically send an F7 Initialization notification to indicate the device is ready to begin initialization.

To insert an SFP:

1. Remove dust covers or plugs from the SFPs, if provided.

2. Slide the SFP into the port, ensuring correct polarity, until the latch clicks into place.

Removing an SFP

To extract an SFP:

Determine what kind of extraction mechanism the SFP has and remove the SFP as follows:

If the SFP has a removal tag, remove the cable from the SFP and then pull the removal tag outward and toward the side of the SFP with the tag.

If the SFP has a small plastic slider on the top or bottom, remove the cable from the SFP and then push in the slider and hold while pulling out the SFP.

If the SFP has a bale (small metal clasp), remove the cable from the SFP and then unlatch, pivot, and pull the bale.

Attaching a Device to the Switch

To attach a device:

1. Make sure that the device is FC-AL compatible.

2. Attach a cable to the device.

3. Attach the other end of the cable to an SFP.

4. Make sure that the device and switch are operational and set to the same speed.

Caution: Forcing an SFP into a port may damage the SFP and/or port.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 2: SWITCH INSTALLATION

EMULEX CORPORATION 13 PART NUMBER 00041392-002 REV. B

BOOTING THE SWITCH AND SAN The following procedure is recommended when booting the switch and SAN. Before powering on the switch and SAN, read the Release Notes, included with the switch contents, to determine any modifications that may be required for a specific installation.

To boot the switch and SAN:

1. Power on the storage devices (such as JBODs, tape libraries, and RAIDs).

2. Insert the plug end of the switchs power cord to a properly grounded power source.

3. Insert the power cords IEC connector end into the switchs power receptacle.

The switch powers on and runs Power-On Self-Test (POST) diagnostics to verify the fundamental integrity of the switch ports. All switch LEDs turn on (LEDs illuminate). Then, excluding the Ethernet Link, Power Supply/Fan Module, and Power LEDs, the LEDs turn off (LEDs extinguish). Once the switch is operational, the LEDs display current status as described in Switch LEDs on page 9.

4. Power on any other switches connected to the SAN.

5. For certain applications, switch configuration must be completed before continuing with the next step. For information regarding switch configuration, see Chapter 3: Switch Management.

6. After all switches have initialized, power on the hosts.

The network initializes.

7. Check all port LEDs.

The SAN should be fully operational at this point. However, it is appropriate to ensure that proper discovery has taken place and all required devices are participating in the network. Some host bus adapters may provide this level of functionality or it might be resident in the application software on the host operating system.

Note: The power cords IEC connector plug serves as the switchs disconnect device. To cycle power to the switch, remove and reconnect the switchs power cord.

Note: FC-AL compatible nodes must perform initialization procedures upon power-up in order to function properly. It is the responsibility of the Fibre Channel driver software on FC-AL nodes to perform this initialization.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 2: SWITCH INSTALLATION

EMULEX CORPORATION 14 PART NUMBER 00041392-002 REV. B

POWER SUPPLY/FAN MODULE REPLACEMENT

The Emulex Model 375 SAN Storage Switch has hot-swappable power supply/fan modules for high availability. A power supply/fan module consists of an individual power supply and a fan bank consisting of three fans.

The switch can run on one functioning power supply/fan module indefinitely, as long as the faulty power supply/fan module remains installed in the switch and there are at least two fans operational in each modules fan bank. If the power supply/fan module is removed from the switch, the switch will continue to operate normally for approximately 20-30 minutes. Non-functional modules should be immediately replaced to maintain high availability.

To remove an old power supply/fan module:

1. Have the new power supply/fan module close to the switch for quick insertion. (This step ensures that the procedure takes no longer than necessarythe switch can only operate with one power supply/fan module installed for approximately 20-30 minutes.)

2. Unplug the power cord from the faulty modules power receptacle.

3. Slide the safety latch over the power receptacle to expose the thumb screw.

4. Loosen the two thumb screws. No tools are required.

5. Pull the unscrewed power supply/fan module out of the switchs module bay using the modules handle.

To insert a new power supply/fan module:

1. Align the power supply/fan module with the module bay opening. Ensure that the warning label is facing upwards on the module.

2. Carefully slide the module into the opening. Ensure that the module is seated firmly in the module bay (the module should be flush with the switchs face).

3. Tighten the two thumb screws. No tools are required.

4. Slide the safety latch over the thumb screw (uncovering the power receptacle).

5. Plug the power cord into the modules module power receptacle.

Note: Keeping spare power supply/fan modules (Part Number 601319) in stock is highly recommended. Contact a sales representative for further information.

Note: The alternate power supply/fan module should remain powered on while the faulty module is removed and replaced to guarantee switch availability.

WARNING To avoid an electrical hazard, never apply power to the power supply/fan module while the module is

removed from the switch.

Note: When using a screwdriver to tighten the thumb screws, ensure that the thumb screws are secure but not overtightened. Overtightening the thumb screws may damage the screws or the module.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 15 PART NUMBER 00041392-002 REV. B

CHAPTER 3 SWITCH MANAGEMENT

This chapter is divided into three sections providing information on how to manage and monitor the switch:

Getting Started Describes how to configure the network interface, use the Web Manager, and perform a basic initial setup of the switch.

Managing the Switch - Describes how to configure the switch and port settings, manage firmware versions and configuration files, set switch thresholds, and configure One-Step Zoning, Automatic Trunking, and Load Balancing.

Monitoring the Switch Describes how to view switch information, the event log, port information, and port diagnostics.

The switch incorporates two distinct interfaces for managing and monitoring purposes:

The Web Manager interface provides an intuitive graphical user interface that enables users to quickly check switch status or modify switch settings in a visual environment.

The Command Line Interface (CLI) provides flexibility and additional functionality for advanced users.

Both of these interfaces provide nearly identical functionality; however, for the purposes of this guide, the Web Manager interface is used for switch and port configuration unless otherwise noted.

For a list of CLI commands, see Appendix B: CLI Quick Reference on page 65. For additional information on the CLI, see the Emulex or InSpeed Storage Switch Products CLI Reference Guide.

Getting Started...........................................................16

Managing the Switch..................................................21

Monitoring the Switch.................................................49

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 16 PART NUMBER 00041392-002 REV. B

GETTING STARTED

This section explains how to configure the switchs ethernet network settings prior to using the Web Manager. Once the switchs network settings are configured, use the Web Manager to perform a quick switch setup.

Configuring the Network Interface

Before using the Web Manager, ensure that the switchs ethernet network parameter settings are correct for the network configuration. The switch ships with the following default IP settings:

IP Address: 169.254.10.10

Netmask: 255.255.0.0

Gateway: 0.0.0.0

To adjust these settings to open the Web Manager, connect to the switch using the provided serial interface cable and follow the instructions below.

To connect through a serial interface:

1. Attach one end of the included RS-232 null modem cable to the computers DB-9 serial port and attach the other end to the switchs DB-9 serial port.

2. Open a terminal session through a serial terminal emulation program (such as HyperTerminal) with the appropriate serial port (for example, COM1) and the following serial port parameters:

Bits per second: 19200 Data bits: 8 Parity: None Stop bits: 1 Flow control: None

3. If using HyperTerminal, press ENTER to receive a prompt.

If using the tip command on a UNIX workstation, do the following:

a. View the /etc/remote file and create an alias similar to Hardware but with the serial port parameters above. (Suggested name: Switch)

b. Use the tip command to establish a connection through the created alias, for example tip switch. (For more information, see the tip command Manual page.)

4. Type the password at the prompt and press ENTER. (The default password is password.)

5. From the serial terminal emulation program, type config network ip and press ENTER.

The switchs current IP parameters are displayed with a prompt for entering the IP address.

6. Change the IP address and press ENTER.

7. Use the mask and gateway commands to change the subnet mask and default gateway respectively.

8. Type save and press ENTER.

9. Type root reset and press ENTER.

10. Type y and press ENTER to reset the switch.

11. Attach the computer to the switchs 10/100 ethernet connector by doing one of the following:

Attach an ethernet RJ-45 cross-over cable directly between the computer and the switch.

Attach two ethernet RJ-45 twisted pair cables from the computer and the switch into an operational ethernet patch panel or hub.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 17 PART NUMBER 00041392-002 REV. B

Connecting to the Web Manager

The Web Manager displays current port utilization and health, enables easy to use Port Smart Settings and One-Step Zoning, and several additional features discussed later in this chapter.

To connect to the Web Manager:

1. Ensure that the workstation has access to the network on which the switch is connected.

2. Open Microsoft Internet Explorer.

3. In the address bar, type the switchs DNS name or IP address and press ENTER.

Web Manager Overview

The Web Manager enables users to view and configure switch and port settings using an intuitive, graphical user interface. The main page is the Switch Information page. This page displays general switch status and continually refreshes to display the most current switch status. For more information on the Switch Information page, see Switch Information on page 50.

To return to this page at any time, click the Storage Switch menu item.

The Web Manager interface consists of a series of command buttons, an expandable navigation menu, and the displayed information area. The command buttons and navigation menu are always present on the page.

Note: The Web Manager supports Microsoft Internet Explorer for Windows version 5.5 or later and Internet Explorer for Apple version 5.2 or later.

Note: The Web browsers appearance and information depends on the switchs active firmware version and may change without notice in subsequent firmware versions.

Command Button Description

Submit Saves any changes made to the switch configuration. This button is disabled until a configuration setting is changed or new information is entered. This button appears green to notify the user of a change to the switch configuration. Click this button to accept the configuration change.

Figure 3-1: Web Manager interface

Navigation Menu

Command buttons

Current page information

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 18 PART NUMBER 00041392-002 REV. B

The expandable navigation menu provides several options for configuring and monitoring the switch. The menu uses a tree-based navigation structure with a list of menu options and items. Clicking a menu option with a "+" next to it expands the menu option and displays additional menu items. Clicking a menu item displays the selected Web Manager page.

To ensure that the most current information is displayed, use the navigation menu instead of the browsers Back and Next buttons, which usually display cached copies and may not reflect current switch information.

To log out of the Web Manager, click Logout, or simply close the browser window.

Documentation

The Web Managers Help menu provides links to online product documentation and firmware downloads.

To access product documentation and firmware:

1. Click Help,and select Documentation > Product Docs or Downloads.

The Emulex Corporations Web site appears.

2. Click the drivers, software and manuals link, and select the switch product model under the Drivers, software and manuals by product model number section.

To view Technical Brief product documentation:

1. Click Help > Documentation > Technical Briefs.

The Emulex Corporations Web site appears.

2. Click the Products tab, select fibre channel switches, and click the technical briefs link under Reports/Briefs.

Cancel Cancels a request. This button is disabled until a configuration setting is changed or new information is entered. This button appears green to notify the user of a change to the switch configuration. Click this button to cancel the configuration change.

Reboot Resets the switch.

Login/Logout Logs in to and out of the switch.

Refresh Redraws the currently displayed Web page.

Note: The Web Manager will automatically log users out after 15 minutes of inactivity, unless the Switch Information page is currently displayed. The Switch Information page automatically updates to display the most current switch status.

Command Button Description

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 19 PART NUMBER 00041392-002 REV. B

Initial Switch Setup

Once a network connection has been established with the switch and an instance of the Web Manager is open, some basic switch configuration tasks are recommended:

Log in to the switch.

Change the switchs password.

Verify the switchs date and time settings.

Change the switchs name.

For additional information on Web Manager features and functionality, see Managing the Switch on page 21 and Monitoring the Switch on page 49.

Step 1: Log in to the Switch

The switch incorporates a password-level security system to prevent unwanted changes to the current switch configuration. In order to make any changes to the switch, users must be logged in to the switch.

To log in to the switch:

1. Click Login on any Web Manager page.

A message box appears confirming the login request.

2. Click OK.

The switch login page appears.

3. Enter the switchs password.

The default password is "password".

4. Click Log In.

A message page appears while the page is loading. If the page fails to load in the indicated time, click Continue.

See Logging in to the Switch on page 22 for additional information.

Step 2: Change the Password

The default password is set at the factory to "password". Change the default password to secure the switch and guarantee that any configuration changes are only performed by registered users.

To change the password:

1. Click Switch > Password.

The Switch Password page appears.

2. Enter the new password in the New Password text box.

3. Enter the new password again in the Confirm New Password text box.

4. Click Submit.

A message box appears confirming the change to the switchs configuration.

5. Click OK.

The Password set success message appears confirming that the new password was saved and activated.

See Changing the Password on page 27 for additional information.

Note: The password must be between 6 and 25 characters in length and is case sensitive.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 20 PART NUMBER 00041392-002 REV. B

Step 3: Verify the Date and Time

During the initial Web Manager session, the date and time for the switch are set based on the host systems current settings.

To view the current date and time:

1. Click Switch > Date & Time.

The Switch Date & Time page appears.

To set the date and time settings:

1. Enter the new date and time settings in the appropriate fields.

2. Click Submit.

The new date and time appear under Current Date & Time.

To synchronize the current date and time settings with the host system:

1. Click Host Time.

The date and time of the current host system appear in the New Date & Time text box.

2. Click Submit.

The new date and time appear under Current Date & Time.

See Configuring Date and Time Settings on page 26 for additional information.

Step 4: Change the Switch Name

While not required, changing the switchs name is recommended for identification and troubleshooting purposes.

To change the switch name:

1. Click Switch > Configuration.

The Switch Configuration page appears.

2. Enter the new name in the Name text box.

3. Click Submit.

The new name appears in the Name text box and also appears in the title bar.

See Switch Identification on page 23 for additional information.

Note: The Web page may have to be refreshed before seeing the name change. Press CTRL+F5 to refresh the Web browser instance or open a new Web browser instance.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 21 PART NUMBER 00041392-002 REV. B

MANAGING THE SWITCH

The Emulex Model 375 SAN Storage Switch provides several options for managing and configuring the switch to meet the needs of the network environment.

This section describes how to log in to the switch, configure switch and port settings, manage firmware and configuration files, and configure One-Step Zoning, Automatic Trunking, and Load Balancing.

Frequent Switch Configuration Tasks

A list of frequent switch configuration-related tasks is provided below. The list displays the task, the corresponding Web Manager command, and a reference to where more information may be found in this guide.

For information on viewing switch status and information, see Monitoring the Switch on page 49.

To Click In this guide, see...

View switch status Storage Switch Viewing Switch Status on page 49.

Change general switch configuration

Switch > Configuration Configuring the Switch Settings on page 22.

Change the IP Address Switch > Configuration Network Location on page 23

Change the switch speed Switch > Configuration Switch Speed on page 24.

View the event log Switch > Event Log Viewing the Event Log on page 52.

Configure traps Switch > SNMP Traps Setting SNMP Traps on page 25.

Upgrade the firmware Switch > Files Switch Firmware Files on page 37.

Change the Port Smart Settings

Port > Smart Settings Configuring the Port Smart Settings on page 29.

Configure One-Step Zoning

Advanced Functions > One-Step Zoning

One-Step Zoning on page 39.

Configure Automatic Trunking

Advanced Functions > Automatic Trunking

Automatic Trunking on page 46.

Configure Load Balancing Advanced Functions > Load Balancing

Load Balancing on page 47.

Reset the switch Reboot Configuring the Switch Settings on page 22.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 22 PART NUMBER 00041392-002 REV. B

Logging in to the Switch

The Web Manager requires users to log in to the switch when changes are made to the switchs configuration. Log in is not required for viewing switch information.

To log in to the switch:

1. Click Login on any Web Manager page.

A message box appears confirming the login request.

2. Click OK.

The Switch Login page appears.

3. Enter the switchs password.

4. Click Log In.

A message page appears while the page is loading. If the page fails to load in the indicated time, click Continue.

Configuring the Switch Settings

Several switch configuration settings may be changed to customize the switch to the network environment. To make a change to the current switch configuration, users must be logged in to the switch or know the switch password (the switch prompts users for the password before accepting changes to any configuration settings).

To change a switch setting:

1. Enter new information or make changes to current settings.

2. Click Submit.

The Web Manager page displays the new settings or information.

Changes to certain switch settings require that the switch be reset for those changes to occur. Users must be logged in to the Web Manager to reset the switch.

To reset the switch:

1. Ensure that any changes to the current switch configuration have been saved.

2. Click Reboot on the Web Manager page.

The switch will reset.

Note: If you do not remember the password, contact a customer service representative.

Figure 3-2: Switch Login page

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 23 PART NUMBER 00041392-002 REV. B

General Switch Settings

The Switch Configuration page displays general settings and switch identification information.

To view the Switch Configuration page, click Switch > Configuration.

Switch Identification

This section includes general switch identification information.

The name, location, and contact name information may be modified for the network environment. The Serial Number setting is factory set and cannot be modified.

To change the name, location, or contact name:

1. Click Switch > Configuration.

2. Enter the new value in the appropriate text box.

3. Click Submit.

The Switch Configuration page displays the updated information.

Network Location

The switchs network location is identified by the IP Address, Netmask, and Gateway fields.

Setting Description

Name The name of the switch.

Location The location of the switch.

Contact Name The person or group to contact about the switch.

Serial Number A unique identification number assigned to each switch at the factory. This setting cannot be configured or modified.

Setting Description

Ethernet IP Address The current IP Address for the switch.

Netmask The current IP Netmask address for the switch.

Default Gateway The current Gateway address for the switch.

Figure 3-3: Switch Configuration page

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 24 PART NUMBER 00041392-002 REV. B

To change the switchs network location settings:

1. Click Switch > Configuration.

2. Enter the new value in the appropriate text box.

3. Click Submit.

The Switch Configuration page displays the updated information.

Version Information

The different software and hardware versions include:

Switch Speed

The Switch Speed setting indicates the current speed per port at which the switch is running. All ports operate at the same speed. The default switch speed is set to 2.125 Gb/s.

To change the switch speed:

1. Click Switch > Configuration.

2. Select the desired speed.

3. Click Submit.

Blocking ARB

When two ports start a communication session, the Blocking ARB is sent to all other ports trying to communicate with those ports until the connection is terminated. The default setting is "FF". If other connected devices use the "FF" setting for another purpose, select another Blocking ARB value (for example, "FB"). Under normal circumstances, this setting does not need to be modified.

Agent Up Time

The Agent Up Time field displays the duration of time that the switch has been operational. If the switch is rebooted or power is cycled, this value is reset.

The Agent Up Time field is for display purposes and cannot be configured.

Setting Description

MAC ID A unique device address (MAC address) assigned to each switch at the factory. This setting cannot be configured or modified.

Switch FW Version The current firmware loaded onto the switch.

Switch HW Version The hardware version of the switch. This setting cannot be configured or modified.

SOC Version The SOC 320 version that is used in the switch. This setting cannot be configured or modified.

MIB Version The proprietary Management Information Base version that is supported through SNMP. This setting cannot be configured or modified.

Setting Description

1 Gb/s Set switch speed to 1.0625 Gb/s.

2 Gb/s Set switch speed to 2.125 Gb/s.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 25 PART NUMBER 00041392-002 REV. B

Setting SNMP Traps

Simple Network Management Protocol (SNMP) uses traps to transmit information to SNMP-based network administration programs. The Switch SNMP Trap Configuration page displays information on the switchs current SNMP trap configuration.

To view the SNMP trap configuration page, click Switch > SNMP Traps.

To configure an SNMP trap:

1. Enter the Trap IP address for the device to which the trap information will be sent.

2. Enter the Trap Port number.

This value is usually set to "162" for Windows and Apple-based networks.

3. Select the State.

4. Click Submit.

When editing a registered IP address, delete the current IP address and create a new entry for the revised IP address.

State Description

Active The trap sends messages to the host identified in the IP Address selection.

Inactive The trap is not operational.

Delete The trap will be deleted from the table once changes are saved.

Figure 3-4: Switch SNMP Trap Configuration page

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 26 PART NUMBER 00041392-002 REV. B

Configuring Date and Time Settings

The Switch Date & Time page displays the switchs current date and time. During the initial Web Manager session, the date and time for the switch are set based on the host systems current settings. If the switch is rebooted or power is cycled, the system clock will reset and the switchs date and time settings will be set to the host systems time settings of the next user to log in to the switch.

To change the time:

1. Click Switch > Date & Time.

The Switch Date & Time page appears.

2. Enter the desired date and time in the appropriate fields.

3. Click Submit.

The new date and time appear under Current Date & Time.

To synchronize time with the host system:

1. Click Host Time.

The date and time of the current host system appear in the New Date & Time text box.

2. Click Submit.

The new time appears under Current Date & Time.

Figure 3-5: Switch Date & Time page

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 27 PART NUMBER 00041392-002 REV. B

Changing the Password

The Switch Password page enables users to change the password for modifying the switchs configuration. The same password is used to access both the Web Manager and the CLI.

To change the password:

1. Click Switch > Password.

The Switch Password page appears.

2. Type the new password in the New Password text box.

3. Type the password again in the Confirm New Password text box.

4. Click Submit. If users are not logged in to the switch, a password prompt appears requesting that the current password be entered. Enter the current password to proceed.

A message displays confirming that the password was saved and activated.

Opening a Telnet Session

Some switch operations may require advanced features currently not found in the Web Manager. These features are available in the Command Line Interface (CLI), which can be accessed through the Web Manager by opening a telnet session to the switch.

To open a telnet session with the switch:

1. Click Advanced Functions > Telnet Session.

A message box appears confirming the opening of a telnet session to the switch.

2. Click OK to proceed.

3. Enter the switchs password and press ENTER.

For additional information on CLI features and functionality, see the Emulex or InSpeed Storage Switch Products CLI Reference Guide.

Note: Until the default switch password is changed, any user with knowledge of the default password can make changes to the switchs configuration.

Note: The password must be between 6 and 25 characters in length and is case sensitive.

Figure 3-6: Switch Password page

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 28 PART NUMBER 00041392-002 REV. B

Adjusting the Switch Thresholds

The Switch Thresholds page displays a variety of switch threshold settings.

To view the current threshold settings:

Click Advanced Functions > Thresholds > Switch.

The Switch Thresholds page appears.

To change switch thresholds or time intervals:

1. Enter the new value in the appropriate text box.

The valid range is displayed next to the text box.

2. Click Submit.

The new value is set.

Setting Description

Ordered Set Error Threshold The maximum number of OS errors allowed in a 10-second interval before a port is bypassed. Setting this value to "0" returns it to the factory default setting. This setting is activated on the Port Smart Settings page.

CRC Error Threshold The maximum number of CRC errors allowed in a 10-second interval before a port is bypassed. Setting this value to "0" returns it to the factory default setting. This setting is activated on the Port Smart Settings page.

Bad Zone Recovery Hold Time (measured in centi-seconds)

The amount of time that the switch keeps the ports in bypass mode before attempting to re-insert the ports into the zone. This setting is activated on the Advanced Functions One-Step Zoning page.

Bad Zone Recovery Delay Time (measured in seconds)

The amount of time that the switch waits after a zone goes down before attempting to recover the zone. This setting is activated on the Advanced Functions One-Step Zoning page.

Port Utilization Interval (measured in seconds)

The length of time between readings of the current ports utilization.

Figure 3-7: Switch Thresholds page

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 29 PART NUMBER 00041392-002 REV. B

Configuring the Port Smart Settings

The Port Smart Settings page displays the current Smart Settings (configuration settings) assigned to each port and enables users to easily create and modify custom Smart Settings.

To view the Port Smart Settings page:

Click Port > Smart Settings.

The Port Smart Settings page appears.

Expanding the optional configuration menus on the right-side of the page by clicking the expand buttons provides additional configuration options.

Figure 3-8: Port Smart Settings page

Expand button

Figure 3-9: Port Smart Settings page (all options displayed)

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 30 PART NUMBER 00041392-002 REV. B

Default Smart Settings

There are several default Smart Settings available on the switch. These default Smart Settings were defined by Fibre Channel storage experts to ensure that the switch is optimally configured for performance and stability.

The default Smart Settings cannot be modified or deleted, but these settings can be used as templates for creating custom Smart Settings.

Initiator or Target

This Smart Setting is the default setting for all switch ports from the factory. This setting offers no change protection and all settings are set to their default values. Initiators and targets can be connected to ports that are set to this Smart Setting.

This is the recommended Smart Setting for setups with targets and initiators connected to a single switch.

Initiator with Stealth

This Smart Setting is used when connecting a host device to the port. When a port is set to this Smart Setting, change notifications are not sent from the initiator to other devices, but change notifications are received by the initiator.

This Smart Setting is appropriate for embedded storage controllers and external Host Bus Adaptors (HBAs) or servers with installed HBAs.

Target with Stealth

This Smart Setting is used when connecting embedded storage devices, like JBODs, SBODs, tape drives, or external RAID systems (JBODs, SBODs, or tape libraries). When a port is set to this Smart Setting, change notifications are sent to other devices, but change notifications are not received by the target.

Fabric Connection

This Smart Setting is used when connecting a port to a Fabric switch. Only one connection from the Emulex Model 375 SAN Storage Switch to a Fabric switch is valid.

Tree Cascade

This Smart Setting is used when connecting two or more switches together in a tree configuration. Up to four tree cascades are supported between switches. See Cascading Switches on page 45 for additional information.

String Cascade

This Smart Setting is used when connecting two or more switches together in a string configuration. Up to four string cascades are supported between two switches. See Cascading Switches on page 45 for additional information.

Before selecting a cascade option, consider the following:

Cascade ports of like number should be connected together. For example, connect port 1 of Switch A to port 1 of Switch B, connect port 2 of Switch B to port 2 of Switch C, and so on.

Cascade port numbers must be lower than non-cascade port numbers (for example, Initiator or Target ports). Therefore, select cascade types before selecting these non-cascade types.

A maximum of three switches may be connected using string cascades.

Note: Changing the Smart Setting of a port may affect the performance or behavior of the system. Depending on the implementation, some Smart Settings are more appropriate than others.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 31 PART NUMBER 00041392-002 REV. B

When configuring multiple switches with a single cascade, use alternating ports. For example, connect the second switch using ports 1 and the third using ports 2 as shown in Figure 3-10.

To assign a Smart Setting to one or more ports:

1. Select the appropriate Smart Setting from the list box.

2. From the list of port numbers, select the ports that will use the selected Smart Setting under the Assign heading.

3. Once completed, click Submit to save the settings.

To set all ports to the currently selected Smart Setting:

1. Select the desired Smart Setting from the list box.

2. Click Set All.

3. Click Submit to save the new settings.

Creating Custom Smart Settings

In addition to the default Smart Settings, users can create custom Smart Settings for use in a specific network environment.

To create a custom Smart Setting:

1. Click Create.

A text box appears prompting for the name of the new Smart Setting.

2. Enter the new Smart Setting name.

A name may consist of up to 28 alphanumeric characters and cannot contain spaces (use underscores for spaces in names).

3. Click OK.

The new Smart Setting is added to the list box.

4. Click Submit to save the new Smart Setting.

Note: The Create function always uses the Initiator or Target Smart Setting as the base setting from which to configure a custom Smart Setting.

Figure 3-10: Alternating Ports for Single Cascades

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 32 PART NUMBER 00041392-002 REV. B

To create a custom Smart Setting based on an existing Smart Setting:

1. Select a Smart Setting from the list box that most closely matches the port settings that the new Smart Setting should have.

2. Click Clone.

3. Enter the new Smart Setting name.

A name may consist of up to 28 alphanumeric characters and cannot contain spaces (use underscores for spaces in names).

4. Click OK.

The new Smart Setting is added to the list box.

5. Click Submit to save the new Smart Setting.

To modify a custom Smart Setting:

1. Ensure that the custom Smart Setting is not currently assigned to a port before making any changes.

2. Select the custom Smart Setting in the list box.

3. Select the new settings.

4. Click Submit to save the new settings.

To rename a custom Smart Setting:

1. Select the desired Smart Setting from the list box.

2. Click Rename.

3. Enter the new Smart Setting name.

A name may consist of up to 28 alphanumeric characters and cannot contain spaces (use underscores for spaces in names).

4. Click OK.

The new Smart Setting name appears in the list box.

5. Click Submit to save the change.

To delete a custom Smart Setting:

1. Ensure that the custom Smart Setting is not selected or currently in use.

2. Select the custom Smart Setting in the list box.

3. Click Delete.

4. Click Submit to save the settings.

Smart Setting Assignments

The Smart Settings are based on several port settings grouped into the following categories:

Port Information

Pre-Insertion Testing

Change Notifications

Port Recovery

Diagnostics

These settings can be adjusted on custom Smart Settings; however, these settings are fixed on the default Smart Settings.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 33 PART NUMBER 00041392-002 REV. B

Port Information

The following settings are available.

Pre-Insertion Testing

The following settings are available.

Setting Description

Smart Setting Name Displays the name of the Smart Setting. The Smart Setting name will automatically appear in the text box when selected in the scroll menu.

Smart Setting Type The topology among switches for a port. Options include: Initiator or Target Port the default setting. Should be used when

there are no links between switches. Tree Cascade designates the port as a tree cascade port. Use

this setting when connecting multiple switches together in a tree cascade configuration. Under most conditions, this setting will result in acceptable performance.

String Cascade 1 through String Cascade 4 designates the string cascade to which a port is assigned. String cascades maintain fairness when two or more InSpeed-based storage switches are serially cascaded. Switch performance may be lower when compared to a tree cascade configuration.

Setting Description

Enable Policies/Smart Insertion

This policy is the default operating mode for all ports and determines what the switch looks for prior to allowing a port to insert into a zone. When the policy is enabled, an external device is sent an F7 Initialization notification by the switch until an F7 Initialization notification is received from the device. Once an F7 Initialization notification is received, the port is inserted in the zone. This policy takes precedence over all other policies. When this policy is disabled, no additional policies are operational, and as long as a port transmits a signal of the correct frequency and amplitude, the port will be allowed in the zone.

Port Test Before Insertion This policy ensures that a device on a port is a valid, standards- compliant participant before allowing the device to be inserted into a zone. The device must meet all of the FC-AL requirements along with going through a complete change notification cycle. During the change notification cycle, the device becomes the Initialization Master (IM) and goes through the change notification phases. Once the change notification cycle is complete, the device can be inserted. This process ensures that a bad device is not allowed into the zone.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 34 PART NUMBER 00041392-002 REV. B

Change Notifications

The following settings are available.

Setting Description

Stealth Intelligent Change Manager

Stealth Intelligent Change Manager provides stability and control over change notification disruptions on a port basis. Options include: Off: No Change Protection no Stealth Intelligent Change

Manager control. Initiator: Only Receive Changes devices attached to the port

can receive change notifications but will not propagate change notifications generated by that port to other ports.

Target: Only Send Changes propagates change notifications generated by the port to other ports but will not allow devices attached to the port to receive change notifications from other ports.

Switch-Switch: Send and Receive Changes allows change notifications to propagate between switches.

Custom-1 Note: This setting should not be used unless directed to do so by a customer service representative.

Change Notification on Insertion

The switch normally operates under the condition that when a device is inserted onto the network, a change notification is generated. However, this condition is not always true when connecting hubs or switches together. In some instances, it is possible to connect two zones together without the zones realizing that multiple AL_PAs exist with the same values. When this policy is enabled, the switch always generates a change notification to ensure that the proper system updates are performed. However, when a device is removed (for example, an initiator or target), the removal does not generate a change notification and there are no system updates performed.

Change Notification on Removal

This policy is similar to the Change Notification on Insertion policy, except for the change notification being sent when a device is removed rather than inserted. When this policy is enabled, the switch always generates a change notification to ensure that the proper system updates are performed.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 35 PART NUMBER 00041392-002 REV. B

Port Recovery

The following settings are available.

Setting Description

Bad Device Recovery When a port is already inserted into a zone, the port transforms F8 Failure notifications into F7 Initialization notifications. When this occurs, the port is bypassed and F7 Initialization notifications are allowed in the zone. Once the initialization is complete, the Bad Zone Recovery Policy is operational and prevents a port that continues to transmit F8 Failure notifications from inserting into the zone.

Note: If this policy is disabled while the Bad Zone Recovery policy is enabled, a zone that does go down will still allow the Bad Zone Recovery policy to reset the zone and allow ports to be reinserted.

When enabled, this policy prevents devices that send F8 Failure notifications from inserting into a zone. The ability to remove devices that generate F8 Failure notifications automatically and instantaneously guarantees continual system operation. When disabled, this policy allows devices that send F8 Failure notifications to insert into a zone and does not consider F8 Failure notifications when determining whether to insert a device or not.

Clear on Stall In situations where the switch is operating in switching mode, some devices may fall into an operating mode where the device has opened a target but has not released the connection to the target. When this policy is enabled, the switch can detect this condition and automatically recover when this situation arises.

Bypass on No Activity The switch detects the amount of time a data stream has gone without receiving a comma. The time setting is set to 100 (.001 seconds). When this policy is enabled, the switch bypasses the disruptive port when the threshold is exceeded.

Bypass on Ordered Set Error

Ordered Set (OS) errors are detected and counted for each individual port. When this policy is enabled, a port is bypassed when its OS count exceeds the threshold setting. The threshold setting is based on the number of ordered set errors identified in 10 seconds.

Note: This threshold setting can be adjusted on the Web Managers Advanced Functions Switch Thresholds page.

Bypass on CRC Error Cyclic Redundancy Check (CRC) errors are detected and counted for each individual port. When this policy is enabled, a port is bypassed when its CRC count exceeds the threshold setting. The threshold setting is based on the number of CRC errors identified in 10 seconds. User intervention is required to return the port into the zone. Recovery methods include replacing the defective component, cycling power to the device on the port, removing and reinserting the bypassed port, or cycling power to the switch.

Note: This threshold setting can be adjusted on the Web Managers Advanced Functions Switch Thresholds page.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 36 PART NUMBER 00041392-002 REV. B

Diagnostics

The following settings are available.

Setting Description

Port Control The method for controlling a port. Options include: auto the default setting. The switch will automatically insert a

port based on policy settings. This prevents the insertion of incompatible ports, which may cause disruption.

bypass removes a port from the network. Use this mode to keep a device out of an initialization cycle when troubleshooting.

extLoopback removes a port from the network and routes the port's receive signal back through the port's transmitter. Use this mode to isolate a specific zone for troubleshooting or to test a transceivers circuitry and attached media from the node end.

insert allows ports whose transceivers cannot derive a valid clock or "K" character (Ordered Set) to join a zone. Use this mode cautiously devices without valid characters may put bad data into a zone, causing the zone to go down.

Bypass on Clock Delta The switch determines the relative frequency of the signal being received by a port to the internal switch clock. The result of this test allows the determination of how far apart in frequency the switchs clock is in relation to the clock of the received signal the clock delta. If the clock delta exceeds a set threshold, the switch is notified and the port may be bypassed if necessary. Typically, clock drift is slow enough to allow the removal and replacement of a defective part before the defective part begins to affect system performance.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 37 PART NUMBER 00041392-002 REV. B

Managing Firmware and Configuration Files

The Switch Files page displays information on the switchs firmware and configuration files.

To view the firmware and configuration files, click Switch > Files.

The Switch Files page appears.

Switch Firmware Files

This section displays the current and alternate firmware versions, enables users to select which firmware version to run the next time the switch is reset, and provides a means to load new firmware on the switch.

To check for new firmware:

1. Click Help and select Downloads.

The Emulex Corporations Web site appears.

2. Click the drivers, software and manuals link, and select the switch product model under the Drivers, software and manuals by product model number section.

To load new firmware on the switch:

1. Under Download New Alternate Firmware Version to Switch, enter the directory path and the specific file name in the text box, or click Browse to navigate to and select the appropriate file on the host system. The file must have a .bin extension.

2. Click Start to load the new firmware image.

Once the firmware has been installed, the new firmware should appear as the Alternate Version firmware.

3. Under Next Boot Firmware Version, ensure that the Use Alternate Version on Next Reboot option is selected. The alternate firmware version currently displayed will be loaded on the next boot cycle.

4. Click Reboot to reset the switch using the selected firmware.

Note: When loading new firmware on the switch, clear the Web browsers cache and files to ensure the removal of the older firmware information. In Internet Explorer, use the key combination CTRL+F5, or select Tools > Internet Options and click Delete Files.

Figure 3-11: Switch Files page

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 38 PART NUMBER 00041392-002 REV. B

To select the alternate firmware version for the next boot:

1. Under Next Boot Firmware Version, select Use Alternate Version on Next Reboot. The alternate firmware version currently displayed will be loaded on the next boot cycle.

2. Click Submit.

3. Click Reboot to reset the switch.

Switch Configuration Files

Switch configuration settings (for example, zoning or Port Smart Settings) can be saved for backup purposes or for loading the same configuration on multiple switches.

To save the current configuration:

1. Click Save to save the current switch configuration.

2. Click OK on the File Download dialog box.

3. Enter the directory path and file name, being sure to use a .cfg extension.

4. Click Save.

To load a saved configuration:

1. Under Download New Configuration File to Switch and Reboot, enter the directory path to the .cfg file in the text box, or use the Browse button to navigate to the appropriate file.

2. In the Choose File dialog box, navigate to and select the appropriate file and click OK.

3. Click Start.

A message box appears confirming the download and required switch reset.

4. Click OK to proceed.

Restoring the Factory Default Settings

If necessary, the switch settings can be reset to their factory default values; however, the network configuration and port type settings are retained.

To restore the factory default configuration:

1. From the Restore Configuration to Factory Default section, click Restore.

A message box appears confirming the request.

2. Click OK to restore the factory default configuration and reset the switch.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 39 PART NUMBER 00041392-002 REV. B

One-Step Zoning

Zoning allows ports to be divided into multiple virtual zones (or work groups), similar to Virtual Local Area Networking (VLAN). By separating activity on the network, zoning also eliminates change notification propagation (change notifications that occur within one zone cannot propagate to other zones.)

Use zoning to:

Separate different operating system environments.

Temporarily block or grant access during backup or other tasks.

Consolidate equipment logically.

Designate closed user groups for increased security.

Separate test or maintenance areas from production areas.

Zone configuration settings are available on the Web Managers One-Step Zoning page. The page is arranged as a grid of check boxes for placing ports in appropriate zones. Ports are listed across the top of the grid. Zonesare listed down the left side.Similar to other Web Manager pages, the port color represents the current port status.

To view the One-Step Zoning page:

Click Advanced Functions > One-Step Zoning.

The switch is capable of up to twelve zones. Initially, all ports reside in Zone 0. However, a port will clear from Zone 0 whenever it is selected and placed in another zone.

The color of each zone indicates its status. See the descriptions in the following table:

Color Description

Down (red) One or more ports have been selected, zoning has been activated, but hardware has caused a failure.

Up (green) Ports have been selected, zoning has been activated, and the FC-AL circuit is operational.

Not Active (yellow) Ports have been selected but zoning has not been activated.

Undefined (gray) No ports have been selected.

Figure 3-12: One-Step Zoning page

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 40 PART NUMBER 00041392-002 REV. B

The Zone Initialization Master Port field displays the port number of the port that is currently assigned as the master for that particular zone. The Initialization Master is responsible for starting the change notification process in each zone.

To add ports to a zone:

1. Select the appropriate check boxes to place ports into zones.

2. Click Submit.

To activate zoning:

1. Select the Zoning Active check box near the bottom of the page.

2. Click Submit.

To remove a port from a zone:

1. Clear the appropriate check box.

2. Click Submit.

To remove all ports from a zone:

1. Click Clear at the end of the row of check boxes for the appropriate zone.

2. Click Submit.

To remove all zones:

1. Click All under the Clear Zone heading.

2. Click Submit.

Single-Switch Zoning

The simplest zoning configuration is to place each port into a single zone, so that zones are separate from each other as shown in Figure 3-13.

In Figure 3-13, zone 1 includes ports 1, 3, and 4, while zone 2 includes ports 2 and 5. Devices on ports 1, 3, and 4 have direct access to each other and devices on ports 2 and 5 have direct access to each other; however, devices 1, 3, and 4 are separated from devices 2 and 5.

Caution: Clearing the Zoning Active check box will deactivate all zones, which may degrade system performance or compromise security.

Figure 3-13: Devices in a Single Zone

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 41 PART NUMBER 00041392-002 REV. B

Adding Devices to Multiple Zones

In the previous example, each host only communicates with the devices in the same zone as the host. However, there may be situations in which hosts in separate zones need to share devices. When this situation occurs, use overlapping zones to share the devices between the hosts. Figure 3-15 depicts this type of zoning configuration.

In Figure 3-15, zone 1 includes ports 1, 3, and 4, while zone 2 includes ports 2, 4 and 5. Port 4 is in both zones. Devices on ports 1, 3, and 4 have direct access to each other and devices on ports 2, 4, and 5 have direct access to each other, but devices 1 and 3 are separated from devices 2 and 5. The device on port 4 has direct access to all the devices on ports 1, 2, 3, and 5.

To add storage devices to multiple zones:

1. Select the appropriate zones for each port.

2. Ensure that the Zoning Active check box is selected.

Figure 3-14: Single switch zoning configuration

Figure 3-15: Devices in Multiple Zones

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 42 PART NUMBER 00041392-002 REV. B

3. Click Submit.

Multiple Switch Zoning Zones can be configured across multiple switches using a similar procedure to a single switch. However, multiple-switch zoning requires some coordination between the switches.

Building on the example for ports in multiple zones, move the devices onto two switches and have the zones stretch between the two, as in Figure 3-17.

In Figure 3-17, zone 1 includes ports 2, 4, 5, and cascade port 1, while zone 2 includes ports 3, 5, 6, and cascade port 1. Ports 1 (cascade port) and 5 are in both zones.

Note: To ensure zone integrity when configuring multiple switch zoning, you must implement AL_PA zoning through the Command Line Interface (CLI). See AL_PA Zoning on page 43 for additional information.

Figure 3-16: Ports in Multiple Zones on the One-Step Zoning page

Figure 3-17: Devices in Multiple Zones Across Multiple Switches

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 43 PART NUMBER 00041392-002 REV. B

To configure multiple-switch zoning, do the following for each switch:

1. Plan which ports should belong in each zone.

2. From the One-Step Zoning page, select the appropriate ports for each zone.

3. Ensure that the Zoning Active check box is selected for both switches.

4. After making changes, click Submit.

AL_PA Zoning

AL_PA zoning is a specific zoning configuration that prevents devices from accessing one another. AL_PA zoning fully ensures that devices will not access each other by blocking a group of devices (using AL_PAs) from communicating with each other; however, AL_PA zoning allows the devices to communicate with devices outside of the group.

AL_PA zoning is only accessible through the Command Line Interface (CLI). Refer to the Emulex or InSpeed Storage Switch Products CLI Reference Guide for additional information.

Recovering a Bad Zone Automatically

Bad zone recovery policy automatically recovers traffic if a device has brought down the zone. The zone state is monitored continuously. If ports are inserted into a zone, but the zone state never transitions to the Zone Up or Zone Active state after a set period of time (Hold Time), all devices in the pertinent zone are bypassed and then allowed to reinsert. There is a secondary timeout, the Bad Zone Recovery Delay Time, that can also be configured. The Bad Zone Recovery Delay Time causes a delay before ports are allowed to reinsert, which prevents a high "thrashing" level of port insertions and de-insertions and ensures that some devices can reset. The Bad Zone Recovery Hold Time and Delay Time threshold settings are available on the Advanced Functions Switch Thresholds page.

When this policy is enabled with the associated PTBI policy, the device causing a zone to go down is not allowed back into the zone due to the PTBI policy, which allows the system to return to normal operation. The combination of the Bad Zone Recovery and PTBI policies has resulted in significant improvements to SAN availability.

To activate bad zone recovery:

1. Click Advanced Functions > One-Step Zoning.

2. Under Bad Zone Recovery, select the check boxes for the appropriate zones.

3. Click Submit.

Caution: Clearing the Zoning Active check box will deactivate all zones, which may degrade system performance or compromise security.

Note: The Bad Zone Recovery policy is enabled by default. If the Bad Zone Recovery policy is disabled, use the following instructions to enable this policy for the appropriate zones.

Figure 3-18: Zones Coordinated on Multiple Switches

Switch A Switch B

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 44 PART NUMBER 00041392-002 REV. B

Connecting Ports Through Hard Zoning

A Hard Zone can be used to add a separate 126 AL_PAs that operate in isolation from any other zone. A Hard Zone disables switching functionality and creates a shared connection between the ports in a zone topology, splitting the switch into multiple unique FC-AL zones. When Hard Zoning is enabled, all switch zones must be Hard Zones. A combination of Hard Zones and regular zones on a single switch is not allowed.

The advantages of Hard Zoning include:

Each Hard Zone contains 126 available AL_PAs.

The switch can be configured to contain up to eleven isolated Hard Zones.

The limitations of Hard Zoning include:

2 Gb of shared bandwidth over the entire Hard Zone.

Ports in a Hard Zone cannot use the Stealth Intelligent Change Manager.

Automatic Trunking and route blocking are not allowed in a Hard Zone.

Ports in a Hard Zone cannot be set to a string or tree cascade configuration.

Device AL_PAs on a port in a Hard Zone cannot be displayed.

The Hard Zone setting is available on the One-Step Zoning page. To view the page, click Advanced Functions > One-Step Zoning.

To set up Hard Zoning:

1. Determine which ports will reside in each Hard Zone and ensure that the ports are in only one Hard Zone.

2. Under Hard Zone, select the check boxes for the appropriate zones.

3. Click Submit.

Caution: Do not set a Hard Zone for ports in multiple zones or share ports that have the Hard Zone option set. This will cause errors that do not log an event or display a message.

Figure 3-19: Hard Zoning configuration

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 45 PART NUMBER 00041392-002 REV. B

Cascading Switches

When multiple switches are connected, the connecting links between the switches are referred to as "cascades". There are two distinct cascade configurations to consider when configuring networks for optimal performance and connectivity: string cascades and tree cascades.

String Cascades

A string cascade connects multiple switches (up to three switches maximum) together in a "daisy- chained" configuration. When one device requests access to another device, the request is sent to each switch in the cascade before device access is granted. This arbitration method promotes fairness between the switches. However, when compared to tree cascades, string cascades offer less performance due to the increased latency between the switches.

When configuring a switch port for a string cascade, use the String Cascade Smart Setting. To enable the string cascade, go to the Automatic Trunking page. From the Automatic Trunking page, select the Single Cascade option, or place the string cascade into a trunk group. See Automatic Trunking on page 46 for additional information.

To reduce contention and improve performance between initiator traffic and target traffic when using a string cascade configuration, connect the ports of each switch together using the same String Cascade Smart Settings. For example, in Figure 3-20 the three switches are connected through two string cascades using the String Cascade - Trunk 1 and String Cascade - Trunk 2 Smart Settings. This creates two dedicated paths through which initiators and targets can communicate.

Tree Cascades

Tree cascades provide the best performance (lowest latency) configuration. A tree cascade consists of a root switch connected to additional switches (up to 8 switches maximum). When a device on a switch requests access to another device, the request is sent the particular switch for that device. The limitation to the tree cascade configuration is the random nature of devices gaining access to one another, as fairness is not used for tree cascades.

When configuring a port for a tree cascade, use the Tree Cascade Smart Setting. To enable the tree cascade, go to the Automatic Trunking page. From the Automatic Trunking page, select the Single Cascade option, or place the tree cascade into a trunk group. See Automatic Trunking on page 46 for additional information.

Figure 3-20: String Cascade configuration example

Figure 3-21: Tree Cascade configuration example

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 46 PART NUMBER 00041392-002 REV. B

Automatic Trunking

Multiple links between switches are called trunks. Trunks provide higher bandwidth across cascaded switches for systems incorporating multiple initiators. Each trunk can improve system throughput and provide failover capability. A maximum of 4 trunks between each switch is supported. Trunking is performed automatically when ports are configured properly. Figure 3-22 is an example of Automatic Trunking.

Each trunk is part of a trunk group. A trunk group consists of two or more cascades between two switches, and these cascades must be the lowest numbered ports on both switches. There can only be one trunk group between two switches. Each trunk group contains a primary trunk. All traffic flows through the primary trunk on a switch unless specified otherwise using the Load Balancing feature. The primary trunk is always the lowest numbered port of any trunk group.

If the primary trunk fails, the secondary trunk automatically becomes the primary trunk unless otherwise configured. Multiple cascades also enable switch configuration for better performance through load balancing (see Load Balancing on page 47).

The Automatic Trunking page enables users to configure trunking by defining trunk groups and assigning ports to those groups. The Automatic Trunking feature is available when one or more ports are assigned a String or Tree Cascade Smart Setting.

Only one of the three following options may be selected for each port.

Device or Initiator Select this option to designate a specific port as an initiator or device. The specified port is not assigned to a trunk group. The Device or Initiator option is the default setting.

Single Cascade Select this option when connecting two switches with a single cascade. The selected port is not part of a trunk group.

Trunk Group Select this option when multiple cascades are connected between two switches. The selected port must be assigned to an available trunk group. Multiple trunk groups appear when two or more ports are assigned to the same string cascade Port Smart Setting (for example, String Cascade - Trunk 1).

Note: Before changing the Port Smart Setting for a particular port assigned to a trunk group, you must remove that port from the trunk group by selecting the Device or Initiator setting. Remember to click Submit to update the ports setting.

Figure 3-22: Automatic Trunking example

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 47 PART NUMBER 00041392-002 REV. B

To assign ports to trunk groups:

1. Click Advanced Functions > Automatic Trunking.

The Automatic Trunking page appears.

2. Select a trunk group for each port by clicking the appropriate Trunk Group option.

3. When finished making changes, click Submit.

Load Balancing

Load balancing builds on the Automatic Trunking functionality by specifying the path that the data uses to flow between multiple switches. Users can manage the switchs aggregate bandwidth by manually distributing traffic across multiple cascade ports as shown below. A cascade port is a port that is attached to another switch of the same type and configured as a String or Tree Cascade Smart Setting on the Port Smart Settings page. All data flows through the primary cascade, unless the switch is configured differently.

Note: Cascade ports must be properly configured before load balancing will work.

Figure 3-23: Advanced Functions: Automatic Trunking page

Figure 3-24: Load Balancing Across Multiple Cascade Ports

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 48 PART NUMBER 00041392-002 REV. B

In Figure 3-24, host 1 uses cascade port 1, while host 2 uses cascade port 2. All traffic will use the lowest numbered (primary) cascade port by default but ports may be configured to use other cascades.

Load balancing configuration settings are available on the Web Managers Load Balancing page. Before implementing load balancing on the switch, the automatic trunking settings must be configured. See Automatic Trunking on page 46 for additional information.

To view the Load Balancing page:

Click Advanced Functions > Load Balancing.

The page is arranged as a grid of check boxes for assigning ports to cascades ("Trunk Groups").

Load Indicators

The Load Balancing page incorporates two sets of visual indicators for measuring traffic:

Port Load Indicatorsthe horizontal bars on the right side of the page that display the current load for each port.

Trunk Load Indicatorsthe vertical bars at the bottom of the page that display the current load for each trunk group.

These bars indicate the amount of traffic across a trunk or port. The size of the bars increase in correlation to the amount of traffic and, as a bars size increases, can identify a specific trunk or port that is overloaded. If overloading occurs, move one or more ports to a different trunk in the group.

To change the load balancing settings:

1. Click a Trunk Group option to place a port into a specific trunk group.

2. Continue to assign ports to trunk groups as necessary.

3. When finished, click Submit.

Note: When tape drives or tape libraries are included in multiple switch configurations incorporating multiple trunks, place the tape drive or tape library and any devices that access those devices on the secondary (duplicate) trunk, not the primary trunk.

Figure 3-25: Load Balancing page

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 49 PART NUMBER 00041392-002 REV. B

Fairness and Prioritization

The concept of "fairness" is based on the principle of ensuring fair device access and communication across all devices in a storage system. The switch incorporates fairness and prioritization through InSpeed technology and Automatic Trunking and Load Balancing functionality. In cooperation with each other, these features ensure even and equal access through multiple links fairlyeffectively multiplying bandwidth.

Device prioritization can be achieved using Load Balancing and assigning only a specific device port to a particular cascade. This ensures that a specific device will always have a dedicated trunk.

MONITORING THE SWITCH

The Emulex Model 375 SAN Storage Switch provides several options for monitoring the switch status and port information. This section describes how to view switch status, the event log, port information and utilization, and port diagnostics.

Viewing Switch Status

The Web Managers home page is the Switch Information page. This page is displayed first when the Web Manager is opened and shows general switch information, including switch status, fan and power supply operational indicators, and port health and utilization.

This page continually refreshes to guarantee that the most current switch status is displayed. To return to this page at any time, click the Storage Switch menu item.

Figure 3-26: Switch Information page

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 50 PART NUMBER 00041392-002 REV. B

Switch Information

Current status is provided for the following items.

Item Status Indicators

Switch Status OK (green)the switch unit is operating normally. Fault (red)one or more of the ports has failed, the internal

temperature has exceeded acceptable levels, or another error has occurred. Errors appear in the event log. The switch will continue to operate; however, functionality may be impaired depending on the event that triggered the error. Regardless of the cause, the switch requires immediate attention.

SOC Status OK (green)the switch chipset is operating normally. Fault (red)the switch chipsets selftest has failed.

Enclosure Temperature OK (green)the switch temperature is within the normal operating range.

OverTemp (red)the enclosure temperature has exceeded the recommended operating range.

Fan #1 OK (green)the fan unit is working properly. Not Present (yellow)the power supply/fan module has been

removed. Fault (red)the fan unit has stopped operating. Verify that the power

supply/fan module is properly seated in the switch.

Fan #2 OK (green)the fan unit is working properly. Not Present (yellow)the power supply/fan module has been

removed. Fault (red)the fan unit has stopped operating. Verify that the power

supply/fan module is properly seated in the switch.

Power Supply #1 OK (green)the power supply unit is working properly. Not Present (yellow)the power supply/fan module has been

removed. Fault (red)the power supply unit has stopped operating. Verify that

the power supply/fan module is properly seated in the switch.

Power Supply #2 OK (green)the power supply unit is working properly. Not Present (yellow)the power supply/fan module has been

removed. Fault (red)the power supply unit has stopped operating. Verify that

the power supply/fan module is properly seated in the switch.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 51 PART NUMBER 00041392-002 REV. B

Port Utilization and Health

Port utilization measures the amount of traffic passing into a port over a period of time. For example, if an initiator is transmitting data to a target, the initiator port displays a port utilization value (%) while the target port does not. If the same initiator is receiving data from the target, the target port displays a port utilization value (%) while the initiator port displays does not.

This part of the Web page displays each port number, the ports current health status, and a vertical bar indicating the port utilization.

A port number is displayed in one of three colors depending on the ports current health:

Port utilization is measured by a vertical bar that moves upwards as utilization increases. The vertical bar has the three distinct levels of utilization:

Tip: Rolling the mouse cursor over the port number displays the current port state.

Port Color Indication

Green An SFP is inserted into the port and a device is connected to the SFP.

Yellow Bypassed The port is bypassed. An SFP may be inserted in the port but there may not be a device connected to the SFP.

Loopback There is no device connected to the port. The transmit and receiver are connected together on the SFP transceiver.

LIPF8Present If the switch is receiving an F8 Failure notification, the port is bypassed to allow remaining devices to proceed with initialization.

Redundant The port is a failover link in a cascade and is not currently active.

Red TxFault Detects an SFP transmitter fault. DiagTx Detects Ordered Sets being transmitted, so traffic cannot be

passed through the port. DataTimeout Detects a data timeout fault. RxLoss Detects a loss of received signal amplitude from the device. SyncLoss Detects a loss of word synchronization for a specified time,

which may be caused by poor signal strength, intermittent line conditions, and so on.

Gray Unknown The port status cannot be determined. NoSFP There is no SFP connector inserted in the port.

Bar Color Indication

Green The port is operating at optimal utilization.

Yellow The port is experiencing periods of heavy traffic.

Red The port has too much traffic on it and is not operating at desired levels. Some devices should be transferred to other ports to improve port utilization.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 52 PART NUMBER 00041392-002 REV. B

Viewing the Event Log

The Event Log contains a list of up to 3000 event log messages generated by the switch. The Switch Event Log page displays the event log messages with each message containing the following information:

Event Number the number assigned to that specific event in the log.

Event Date and Time the date and time when the event was recorded in the log.

Event Severity the severity level for that event.

Event Type the identifier assigned to that event.

Event Description a brief description of the event.

For a list of event messages and severity levels, see Appendix C: Event Messages on page 68.

To view the event log:

Click Switch > Event Log.

The Event Log Messages page appears.

The last time the event log was polled appears at the top of the page.

To export the event log:

1. Click Export.

If the File Download dialog box appears, select Save this file to disk, and click OK to save the file on the host system. The Save As dialog box appears. Select the appropriate directory, change the file name if necessary, and click Save.

The event log appears in the host systems default text editor.

2. Select the appropriate directory to save the event log messages, change the name of the file (if desired), and save the event log.

To delete the current list of event log messages on the switch:

1. Click Clear.

A message box appears confirming the request.

2. Click OK to delete the event log.

The event log is cleared out and a new event message is displayed reporting that the event log has been cleared.

Figure 3-27: Switch Event Log page

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 53 PART NUMBER 00041392-002 REV. B

Viewing Port Information

The Port Information page displays the Smart Settings, Serial ID (SID), and AL_PAs currently assigned to each port. Initiator AL_PAs are highlighted in blue to differentiate them from target AL_PAs.

To view port information:

Click Port > Information.

The Port Information page appears.

Note: The Initiator AL_PA information can be used to easily identify attached devices when configuring load balancing.

Field Description

Port Displays the current health of the port. See Port Utilization and Health on page 51 for additional information on port health.

Smart Setting Displays the specific Smart Setting assigned to a particular port. See Configuring the Port Smart Settings on page 29 for more information on the Smart Settings.

Serial ID (SID) When clicked, provides additional information about the SFP inserted in the port, if an SFP is inserted in that particular port.

Identified ALPAs Displays all the AL_PAs attached to the port. Initiator AL_PAs appear highlighted in blue.

Figure 3-28: Port Information page

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 54 PART NUMBER 00041392-002 REV. B

Viewing Port Utilization

Port utilization measures the amount of traffic passing through a port over a period of time. For example, if an initiator is transmitting data to a target, the initiator port displays a port utilization value (%) while the target port does not. If the same initiator is receiving data from the target, the target port displays a port utilization value (%) while the initiator port displays does not.

The Port Utilization page displays each ports utilization percentage based on high, average, and low utilization.

To change the port utilization interval:

Click Advanced Functions > Thresholds > Switch. See Adjusting the Switch Thresholds on page 28 for additional information.

To view port utilization:

Click Port > Utilization.

The Port Utilization page appears.

Value Description

High The highest percentage of data communication through a port over a period of time (measured in seconds).

Average The average percentage of data communication through a port over a period of time (measured in seconds).

Low The lowest percentage of data communication through a port over a period of time (measured in seconds).

Figure 3-29: Port Utilization page

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 55 PART NUMBER 00041392-002 REV. B

Viewing Port Diagnostics

This page displays diagnostic information pertaining to each port in the switch. Use the information provided on this page to diagnose abnormally high error counts on a particular port.

To view the current diagnostic settings:

Click Advanced Functions > Diagnostics > Port.

The Port Diagnostics page appears.

Statistic Description

Port & Health Color Indicators Green Yellow Red See Port Utilization and Health on page 51 for descriptions of the health indicators.

Insertion Count Number of times this port has been inserted into the network since the switch was reset or the counters were cleared.

CRC Errors Number of CRC errors that are detected in frames passing through this port since the switch was reset or the counters were cleared.

Ordered Set Errors Number of Ordered Sets that are received on this port with an encoding error since the switch was reset or the counters were cleared.

Clock Delta Difference (in parts per million) between the internal switch clock and the received clock signal on the port.

State Current state of this port either inserted or bypassed

Beacon Port Forces both port LEDs to flash on and off continuously. Use this to locate and take action on a specific port. The flashing overrides normal port indication until beaconing is turned off; however, port operation continues to operate normally.

Figure 3-30: Port Diagnostics page

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 56 PART NUMBER 00041392-002 REV. B

To save diagnostic information:

1. Click Upload to save the current diagnostics to the host system.

2. Click OK on the File Download dialog box.

3. Enter the directory path and file name.

4. Click Save.

To clear the counters:

Click Clear.

Manual Port Operation

If necessary, a port can be placed into manual bypass mode or reset. If the port is placed in bypass mode, the port will remain in bypass mode until the switch is reset. If the port is manually reset, the port is temporarily placed in bypassed mode and then reset to re-insert the port. These features may be used to diagnose device problems when a device is locked up or experiencing a high number of failures on a port.

To place a port into bypassed mode:

1. Click Advanced Functions > Diagnostics > Port.

2. Select the Bypass Port option for the appropriate port.

3. Click Submit.

To reset a port:

1. Click Advanced Functions > Diagnostics > Port.

2. Select the Reset Port option for the appropriate port.

3. Click Submit.

Bypass Port A single instance operation that forces a port into bypass mode. This feature may be used to diagnose device problems when a device is locked up or experiencing a high number of failures on a port.

Reset Port A single instance operation that places a port in bypass mode and then immediately sets the port to auto-detect to re-insert the port. This feature may be used to diagnose device problems when a device is locked up or experiencing a high number of failures on a port.

Statistic Description

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 57 PART NUMBER 00041392-002 REV. B

Viewing Ordered Sets

This page displays the Ordered Sets that are being transmitted on the switch for each port since the last time the page was displayed. Ordered Sets are used when communicating data across networks to indicate actions, events, or status regarding the data. A list of detected Ordered Sets and their indications is provided below.

To view ordered sets:

1. Click Advanced Functions > Diagnostics > Ordered Sets.

The Ordered Sets page appears.

Detection Indication

End of Frame (EOF)

An End-of-Frame (EOF) delimiter has been detected; frames are present. (An EOF immediately follows the CRC of a frame and signals the frames end.)

Start of Frame (SOF)

A Start-of-Frame (SOF) delimiter has been detected; frames are present.

Idle Sequences of IDLEs are being transmitted to maintain link activity; no other data is being transmitted.

ARB(FF) ARB(FF)s are being transmitted to maintain link activity; no other data is being transmitted.

ARB A port is arbitrating for network access to perform a task.

Read Ready (RRDY)

The receiving node on this port has sent an R_RDY signal, indicating that it is ready for a frame to be transmitted over the link.

Close (CLS) The port is attempting to begin the process of closing the current FC-AL circuit.

Open (OPN) The port is attempting to open communications with another port.

Note: As is the case with some ordered sets, an OPN may not go all the way around the FC-AL, instead stopping at its destination.

F8 Failure A non-switching port has detected a failure on its receive input, is notifying other ports, and is determining whether the network is still operational. Some events that could cause the port to detect network failure follow: A device has failed or has been powered off. The physical connection between the transmitter and receiver is broken. Activating the port bypass circuit does not typically result in a network failure.

Figure 3-31: Advanced Functions: Ordered Sets page

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT

EMULEX CORPORATION 58 PART NUMBER 00041392-002 REV. B

F7 Initialization A port is in the non-participating mode and is attempting to win arbitration and begin initialization, possibly because the port was reset or is powering up. Sometimes the port is sending this sequence to another hot-cascaded switch, like a new initiator being inserted in the network.

Change Notification

A change notification has been detected and action has been taken.

Unknown The switch cannot determine what is being transmitted.

Invalid An invalid transmit word has been detected.

CRC Error A Frame CRC error has been detected.

Point-to-Point A point-to-point connection has been detected.

Detection Indication

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 4: TECHNICAL REFERENCE

EMULEX CORPORATION 59 PART NUMBER 00041392-002 REV. B

CHAPTER 4 TECHNICAL REFERENCE

TROUBLESHOOTING DEVICE CONNECTIONS

Troubleshooting Device Connections.........................59

Troubleshooting Management Connections ...............60

Port Bypass Conditions and Recovery .......................60

Default Smart Setting Attributes.................................61

Fibre Channel References .........................................62

Problem Recommended Action

SFP installed in one or more ports but no LEDs lit

1. Verify that the power cord is firmly seated into switch and is connected to a properly earthed receptacle (outlet).

2. Check the Power LED to ensure that the switch is turned on. 3. Verify that the SFP is firmly seated.

SFP installed but only yellow LED is lit

Reseat the SFP. If the same condition occurs, the SFP is probably faulty and should be replaced.

SFP installed with both green and yellow LEDs lit

1. Make sure that the device is powered on and operating properly.

2. Unplug the fiber cable from the node and verify that an optical signal is present on the cable receiver lead.

3. Verify that the fiber cable is fully seated at either end. If optical power meter is available, verify the device is transmitting a signal. If there is no signal present, the device may require rebooting, device drivers may need to be reinstalled, or the HBA or disk controller hardware may require servicing. If a signal is present on both the cable lead and the end node, the HBA or disk controller may require service.

4. Ensure that the device and switch are operational and set to the same speed.

SFP installed with only green LED lit, but devices are not communicating

The switch is receiving a valid signal from the device, but no upper level protocols are active.

1. Verify that the proper HBA device drivers are loaded for the appropriate operating system and that the host has been configured to recognize attached disk devices.

2. Improper FC-AL initialization could result from a defective or inoperative adapter card or device. Run adapter diagnostics with a loopback connector to see if the adapter is working properly.

3. Unplug the fiber cable from the end node and verify that an optical signal is present on the cable receiver lead. If no signal is present, the cables receiver lead may be bad and the device may be streaming F8 Failure notifications.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 4: TECHNICAL REFERENCE

EMULEX CORPORATION 60 PART NUMBER 00041392-002 REV. B

TROUBLESHOOTING MANAGEMENT CONNECTIONS

PORT BYPASS CONDITIONS AND RECOVERY

Problem Recommended Action

Serial cable installed but connection does not appear on terminal

1. Cycle power by reinstalling the power cord. 2. Check the terminal emulation programs serial port parameters.

3. Replace the serial cable. (Make sure it is a null modem cable.)

Ethernet cable installed but Web Manager does not appear

1. Ensure that a crossover ethernet cable is used (unless using an ethernet hub).

2. Check the IP addresses on the switch and workstation as follows:

At a command line prompt, type ping DNSorIP (where DNSorIP is the switchs DNS name or IP address) and press ENTER. If a Reply from or ...is alive... message appears, the devices can communicate. If a Request timed out message appears (or the command times out), the devices cannot communicate. Trace the cabling. If needed, reconnect the devices.

Operational Condition Recovery

Rx_los is asserted by an SFP/GBIC

The port stays bypassed until rx_los is de-asserted. At that time, the port insertion will be automatically retried. The port continues to stay bypassed until the port can pass the port insertion criteria.

Tx_fault is asserted by an SFP/GBIC

The port stays bypassed until tx_fault is de-asserted. At that time, the port insertion will be automatically retried. The port continues to stay bypassed until the port can pass the port insertion criteria.

F8 Failure notification is received by the port (when the LIP F8 Recover policy is enabled)

The switch automatically tries to re-insert the device, by sending F7 Initialization notifications to the device connected to the bypassed port. The port continues to stay bypassed until the device returns F7 Initialization notifications to the port and passes the port insertion criteria.

Loss of Sync (>100ms) The port stays bypassed until a signal is re-established. At that time, the port insertion will be automatically retried. The port continues to stay bypassed until the port can pass the port insertion criteria.

Firmware Initiated The port stays bypassed until the firmware sets the port control back to automatic. At that time, the port insertion will be automatically retried. The port continues to stay bypassed until the port can pass the port insertion criteria.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 4: TECHNICAL REFERENCE

EMULEX CORPORATION 61 PART NUMBER 00041392-002 REV. B

DEFAULT SMART SETTING ATTRIBUTES

In it

ia to

r o

r Ta

rg et

In it

ia to

r w

it h

S te

al th

Ta rg

et

w it

h S

te al

th

F ab

ri c

C o

n n

ec ti

o n

Tr ee

C as

ca d

e

S tr

in g

C as

ca d

e --

Tr u

n k

1

S tr

in g

C as

ca d

e --

Tr u

n k

2

S tr

in g

C as

ca d

e --

Tr u

n k

3

S tr

in g

C as

ca d

e --

Tr u

n k

4

Smart Setting Name

Initiator or Target

Initiator with Stealth

Target with Stealth

Fabric Connection

Tree Cascade

String Cascade --Trunk 1

String Cascade --Trunk 2

String Cascade --Trunk 3

String Cascade- -Trunk 4

Smart Setting Type

Initiator or Target Port

Initiator or Target Port

Initiator or Target Port

Tree Cascade

Tree Cascade

String Cascade 1

String Cascade 2

String Cascade 3

String Cascade 4

Smart Insertion Policy

Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled

Port Test Before Insert Policy

Enabled Enabled Enabled Disabled Disabled Disabled Disabled Disabled Disabled

Stealth Intelligent Change Manager

Off: No Change Protection

Initiator: Only Receive Changes

Target: Only Send Changes

Off: No Change Protection

Switch- Switch: Send and Receive Changes

Switch- Switch: Send and Receive Changes

Switch- Switch: Send and Receive Changes

Switch- Switch: Send and Receive Changes

Switch- Switch: Send and Receive Changes

Change Notification on Insertion Policy

Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled

Change Notification on Removal Policy

Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled

Bad Device Recovery Policy

Disabled Enabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled

Clear on Stall Policy

Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled

Bypass on No Activity Policy

Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled

Bypass on OS Error Policy

Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled

Bypass on CRC Error Policy

Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled

Port Control Auto Auto Auto Auto Auto Auto Auto Auto Auto

Bypass on Clock Delta Policy

Disabled Disabled Disabled Disabled Disabled Dis- abled

Dis- abled

Dis- abled

Dis- abled

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE CHAPTER 4: TECHNICAL REFERENCE

EMULEX CORPORATION 62 PART NUMBER 00041392-002 REV. B

FIBRE CHANNEL REFERENCES The following books give useful information about Fibre Channel.

Alan F. Benner, Fibre Channel. McGraw-Hill, 1996. ISBN 0-07-005669-2.

Tom Clark, Designing Storage Area Networks. Addison Wesley Longman, 1999, ISBN 0-201-61584-3.

Jan Dedek, Fibre Channel - The Basics. ANCOT Corporation, 1997. ISBN 0-9637439-3-7.

Robert Kembel, Arbitrated Loop. Connectivity Solutions, 1996. ISBN 0-931836-82-4.

Robert Kembel, A Comprehensive Introduction. Connectivity Solutions, 1998. ISBN 0-931836-84-0.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE APPENDIXES

EMULEX CORPORATION 63 PART NUMBER 00041392-002 REV. B

Appendixes

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE APPENDIX A: SPECIFICATIONS

EMULEX CORPORATION 64 PART NUMBER 00041392-002 REV. B

APPENDIX A Specifications

SWITCH SPECIFICATIONS

OPERATING CONDITIONS

The switch must be operated in a clean, dry environment with unrestricted airflow. Air flows in through the cosmetic end and out through the business end (sometimes called the transceiver end or back-of-box).

To avoid overheating, maintain a minimum clearance of two inches (50.8 millimeters) on each end of the switch (the cosmetic end and the business end). Allow an adequate amount of space on the top and sides of the switch for proper air ventilation. Do not place the switch on heat-generating surfaces. Operating conditions are listed below.

Specification Value

Number of Ports 20

Operating Rate All ports operate at 1.0625 or 2.125 Gbps (selectable)

Port Media Type SFP

Enclosure 1U full-rack form-factor

Management Interface RS-232 or 10/100 Ethernet

Operating Mode Switching or Non-switching modes

Configurability Management interface configurable

Power On Selftest (POST) Yes

Dimensions 17.20" x 1.57" x 17.50" (W x H x D)

AC Power Input 50 or 60 Hz / 100 250 VAC / 1.0 0.5 A

AC Power Connector IEC connector

Weight Approximately 18 lbs.

Requirement Value

Operating Temperature 0C to 40C normal operation (ambient air temperature)

Storage -40C to 80C non-condensing

Power 50 or 60 Hz / 100 250 VAC / 1.0 0.5 A

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE APPENDIX B: CLI QUICK REFERENCE

EMULEX CORPORATION 65 PART NUMBER 00041392-002 REV. B

APPENDIX B CLI Quick Reference

CONNECTING TO THE CLI The Command Line Interface (CLI) can be accessed through a network interface using a terminal emulation program, such as HyperTerminal, or through the serial interface from a local computer. Refer to the Emulex or InSpeed Storage Switch Products CLI Reference Guide for detailed descriptions of CLI commands and usage.

To connect through a network interface:

Use a network terminal emulation program. For example, if using the telnet command on a Windows workstation, type telnet IPaddress at a command prompt.

To connect through a serial interface:

1. Attach one end of the included RS-232 null modem cable to the computers DB-9 serial port, and attach the other end to the switchs DB-9 serial port.

2. Open a terminal session through a serial terminal emulation program (such as HyperTerminal) with the appropriate serial port (for example, COM1) and the following serial port parameters:

Bits per second: 19200 Data bits: 8 Parity: None Stop bits: 1 Flow control: None

3. If using HyperTerminal, press ENTER to receive a prompt.

4. If using the tip command on a UNIX workstation, do the following: a. View the /etc/remote file and create an alias similar to Hardware but with the serial port

parameters above. (Suggested name: Switch) b. Use the tip command to establish a connection through the created alias, for example

tip switch. (For more information, see the tip command Manual page.)

LOGGING IN AND OUT

The CLI does not require login if only viewing basic system information. However, for viewing detailed system information or configuring any switch settings, users must log in to the switch.

To log in to the CLI: Type the password at the prompt and press ENTER. (The default password is password.)

To log out of the CLI: Type lo and press ENTER, or exit the terminal session.

Connecting to the CLI ................................................65

Logging In and Out ....................................................65

Using the CLI .............................................................66

Frequent Switch Configuration Tasks.........................66

CLI Commands ..........................................................67

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE APPENDIX B: CLI QUICK REFERENCE

EMULEX CORPORATION 66 PART NUMBER 00041392-002 REV. B

USING THE CLI The CLI enables users to monitor and change system and port configurations, configure One-Step Zoning, Automatic Trunking, Load Balancing, and event reporting parameters, and download and install firmware.

For additional information on the CLI, see the Emulex or InSpeed Storage Switch Products CLI Reference Guide.

To enter a command:

Type the command text or the number of the command.

To return to the previous menu:

Type .. and press ENTER.

To return directly to the Root menu:

Type root and press ENTER.

To cancel a prompt or input request:

Press ENTER.

To display help for specific command:

Type ? and press ENTER.

To save changes to the switch configuration at any time:

1. Type save at any command prompt and press ENTER.

A message appears confirming the request.

2. Type y and press ENTER.

FREQUENT SWITCH CONFIGURATION TASKS

A list of frequent switch configuration-related tasks is provided below. The list displays the task and the corresponding CLI command.

To Type

View switch status show sysinfo

Change general switch configuration config sys

Change the IP Address config network ip

Change the switch speed config sys speed

View the event log show events

Upgrade the firmware fw

Change the port settings config port

Configure zoning config zone

Configure trunking config load

Configure load balancing config trunk

Reset the switch reset

Perform diagnostics diag

Reset the switch to factory default settings config default

Change the password config password

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE APPENDIX B: CLI QUICK REFERENCE

EMULEX CORPORATION 67 PART NUMBER 00041392-002 REV. B

CLI COMMANDS

All of the CLI commands for the Emulex Model 375 SAN Storage Switch are shown below in a tree diagram. Using the help command at the command line may provide additional information.

root --> 1. config --> 1. save

help li lo save

2. sys --> 1. speed 2. mode 3. oserr 4. crcerr 5. blkarb 6. clkd 7. time

8. lipen 9. name 10. location 11. contact 12. syslog 13. events 14. sev

15. fault 16. evclr 17. clrled 18. .. 19. ?

3. default

4. port --> 1. beacon 2. show 3. types 4. add

5. view 6. edit 7. del 8. type

9. .. 10. ?

5. password

6. load --> 1. show 2. lbclr 3. delprt 4. addprt

5. delalpa 6. addalpa 7. ialpa 8. util

9. pu1 10. pu2 11. .. 12. ?

7. trunk --> 1. addprt 2. delprt

3. showmem 4. clr

5. .. 6. ?

8. network --> 1. reset 2. show 3. ip

4. mask 5. gateway 6. ..

7. ?

9. zone --> 1. bzht 2. bzdt 3. addprt 4. delprt 5. showmem 6. act

7. deact 8. zstate 9. zclr 10. addblk 11. delblk 12. showblks

13. hz 14. bzr 15. alpas 16. .. 17. ?

10. ..

11. ?

2. diag --> 1. galpa 2. glim 3. os 4. ps

5. delta 6. showpri 7. prtctrs 8. clrctr

9. beacon 10. con 11. who 12. ialpa

13. .. 14. ?

3. show --> 1. events 2. ptype 3. portinfo 4. prtctrs 5. clrctr

6. sysinfo 7. zninfo 8. lbinfo 9. os 10. galpa

11. glim 12. sensors 13. getcon 14. sync 15. dump

16. sid 17. zalpas 18. .. 19. ?

4. fw --> 1. tftp 2. xmodem

3. revert 4. show

5. reset 6. ..

7. ?

5. reset

6. ?

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE APPENDIX C: EVENT MESSAGES

EMULEX CORPORATION 68 PART NUMBER 00041392-002 REV. B

APPENDIX C Event Messages

The event messages for the switch are listed below. For explanations, contact a customer service representative. The messages applicable severity level as defined below is also provided.

These severity levels can be used to designate which events trigger trap messages. Use the Command Line Interface (CLI) to designate the minimum severity level of events to be logged in the Event Log and at which severity level to illuminate the switchs Fault LED.

Severity Level

Severity Description

1 EMERG Immediate action required; system failing

2 ALERT Unrecoverable condition reported; major event in progress

3 CRIT Event failed with possible loss of integrity

4 ERR Condition failed; action required

5 WRN Failed event occurred; no action required

6 NOTIFY Configuration error or abnormal event occurred; no action required

7 INFO Event occurred; no action required

Event Event Message Severity

1 Message log cleared INFO

5 Power Supply # Failed ALERT

6 Power Supply # Online NOTIFY

7 Power Supply # Removed ALERT

8 Power Supply # Inserted NOTIFY

9 Fan has stopped EMERG

10 Fan has returned ALERT

19 Temperatures over limit ALERT

20 Temperature OK INFO

50 SPF Overvoltage EMERG

54 SOC has detected a CRC error in the EEPROM NOTIFY

70 PORT # bypassed NOTIFY

71 PORT # inserted NOTIFY

72 Transceiver detected at port # NOTIFY

73 Transceiver removed at port # NOTIFY

74 SEOC occurred on PORT # NOTIFY

75 Port exceeded OS threshold NOTIFY

76 Port exceeded CRC threshold NOTIFY

77 Loop UP on Port # NOTIFY

78 Loop DOWN on Port # NOTIFY

79 PORT received a LIP(F8) WRN

80 PORT CRC Error detected in frame WRN

81 PORT did not receive LIPF7) within timeout WRN

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE APPENDIX C: EVENT MESSAGES

EMULEX CORPORATION 69 PART NUMBER 00041392-002 REV. B

82 PORT is ready to be inserted DBG

83 Segment stall on PORT # NOTIFY

84 Bad Open on PORT # WRN

85 Error during Port Disc. NOTIFY

86 PORT PTBI failed due to timeout NOTIFY

87 PORT changed to STATE NOTIFY

88 Transceiver in PORT has been cycled NOTIFY

89 PORT has cycled between insert/bypassed (not necessarily in that order)

NOTIFY

90 Loop CYCLED on Port # NOTIFY

91 Port exceeded Clk Delta threshold INFO

95 Interframe has been received INFO

96 Interswitch link added/removed INFO

97 LIP Cycle Timeout INFO

98 API Initialized OK INFO

99 Selftest failure ERR

100 Received Unknown event INFO

101 CRC detected on either an ISL LIP or Generic Frame NOTIFY

107 Trap task failed to update trap destination info. CRIT

135 CLI level 1 password changed NOTIFY

136 CLI level password changed to default setting NOTIFY

150 WEB level 1 password changed NOTIFY

151 Web password level changed to default setting NOTIFY

165 System config reset to factory default ERR

166 New Port Config Type added NOTIFY

167 Port Config Type deleted NOTIFY

168 Current Config saved to flash NOTIFY

169 Error in saving config file to flash ERR

170 Error in retrieving config information ERR

171 Config File successfully configured system NOTIFY

172 Error in initializing system with config file ERR

198 A device tried to access another device that was not in the same zone

NOTIFY

199 Health timer has expired on ZONE NOTIFY

208 PORT is over threshold NOTIFY

218 Trunk DOWN on PORT # NOTIFY

219 Trunk UP on PORT # NOTIFY

220 New Primary Trunk NOTIFY

Event Event Message Severity

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE APPENDIX D: AL_PA CROSS REFERENCES

EMULEX CORPORATION 70 PART NUMBER 00041392-002 REV. B

APPENDIX D AL_PA Cross References

Arbitrated Loop Physical Addresses

AL_PA AL_PA ID AL_PA AL_PA ID AL_PA AL_PA ID

(hex) (hex) (decimal) (hex) (hex) (decimal) (hex) (hex) (decimal)

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

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE APPENDIX E: GLOSSARY

EMULEX CORPORATION 71 PART NUMBER 00041392-002 REV. B

APPENDIX E Glossary

AL_PA or Arbitrated Loop Physical Address

A one-byte value used to identify a port in an Arbitrated Loop topology. The value of the AL_PA corresponds to bits 7:0 of the 24-bit Native Address Identifier.

Arbitration The process of selecting one respondent from a group requesting service at the same time.

Close (CLS) An Arbitrated Loop protocol used to terminate a loop circuit.

Current Fill Word The fill word that the Loop Port State Machine uses when a fill word is to be transmitted.

Duplex Cable Two fibers in one cable suitable for duplex transmission.

Fiber Optics Light transmission through optical fibers for communication or signaling

Fibre Channel Fibre Channel is a data transfer interface technology that maps several common transport protocols including IP and SCSI, allowing it to merge high-speed I/O and networking functionality in a single connectivity technology. Fibre channel is an open standard as defined by ANSI and OSI standards and operates over copper and fiber optic cabling at distances of up to 10 Kilometers. It is unique in its support of multiple interoperable topologies including point-to-point, arbitrated-loop and switching and it offers several qualities of service for network optimization. With its large packet sizes, Fibre Channel is ideal for storage, video, graphic and mass data transfer applications.

LED Light-Emitting Diode. A status indicator on a switch.

Gb/s Gigabits per second.

Node An entity with one or more N_Ports or NL_Ports.

Open (OPN) An Arbitrated Loop protocol used to establish a loop circuit.

Protocol A data transmission convention which may include timing, control, formatting, error detection with correction and data representation.

SCSI Small Computer System Interface. Standard interface for storage modules.

SFP Small Form-Factor Pluggable transceiver. These transceivers are fully compliant with FC-PI and MSA standards and occupy less than half the board space of the existing GBIC products.

Topology The logical and/or physical arrangement of stations on a network. Fibre Channel topologies include point-to-point, Arbitrated Loop, and switched fabric.

Transceiver A device that converts one form of signaling to another for both transmission and reception. SFPs and GBICs are transceivers.

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE INDEX

EMULEX CORPORATION 72 PART NUMBER 00041392-002 REV. B

Index

A AL_PA Cross References 70 AL_PA zoning 43

B Bad Device Recovery policy 35 Bad Zone Recovery policy 43 Blocking ARB 24 Bypass on Clock Delta policy 36 Bypass on CRC Error policy 35 Bypass on No Activity policy 35 Bypass on OS Error policy 35

C cascades 45

strings 45 trees 45

Change Notification on Insertion policy 34 Change Notification on Removal policy 34 change notifications 34 Clear on Stall policy 35 CLI

commands 67 connecting 65 frequent tasks 66 logging in and out 65

configuration files 37, 38 configuring

network interface 16 Smart Settings 29 switch settings 22 Web Manager 17

custom Smart Settings 31

D date and time settings 26 desktop installation 7 device prioritization 49 diagnostics 36

port 55 displaying

event log 52 ordered sets 57 port diagnostics 55 port information 53 port utilization 54 switch status 49

documentation 18 downloading firmware 37

E ethernet LEDs 9 event log 52

messages 68

F Fabric Connection Smart Setting 30 features, switch 2 Fibre Channel references 62 firmware 37

changing versions 38 loading 37

G glossary 71

H hard zoning 44

I Initialization Master 40 Initiator or Target Smart Setting 30 Initiator with Stealth Smart Setting 30 InSpeed Technology 2 installation, switch 6, 7

UL guidelines 7 installing the switch 6 introduction 1

J joining multiple switches 45

L LEDs

2 Gb/s 10 ethernet 9 port 10 Port Bypassed 10 POST Fault 10 Power 10 power supply/fan module 11 SFP Status 10 switch 9 Switch Operational 10 system 10

load balancing 47 loading firmware 37 logging in and out 65 logging in to the switch 22

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE INDEX

EMULEX CORPORATION 73 PART NUMBER 00041392-002 REV. B

M managing the switch 21 monitoring the switch 49

N network interface configuration 16 network settings 23

O operating conditions 64 operating speed 24 ordered sets 57 overview 1

P password 65

changing 27 policies 33, 34, 35, 36

Bad Device Recovery 35 Bypass on Clock Delta 36 Bypass on CRC Error 35 Bypass on No Activity 35 Bypass on OS Error 35 Change Notification on Insertion 34 Change Notification on Removal 34 Clear on Stall 35 Port Test Before Insert (PTBI) 33

port diagnostics 55 hard zoning 44 information 53 Smart Settings 30

assignments 32 change notifications 34 creating custom 31 diagnostics 36 Fabric Connection 30 Initiator or Target 30 Initiator with Stealth 30 port information 33 port recovery 35 pre-insertion testing 33 String Cascade 30 Target with Stealth 30 Tree Cascade 30

utilization 54 port bypass 56

conditions and recovery 60 port information 33 port LEDs 10 port reset 56 Port Test Before Insert (PTBI) policy 33 ports

in multiple zones 41 power supply/fan module 14

LED 11 powering on the switch 13 pre-insertion testing 33 prioritization of devices 49

R rack installation 7

UL guidelines 7 references, Fibre Channel 62

S serial interface connection 65 SFP

attaching devices 12 compatibility 12 installation 12 removal 12

shipped contents 6 Smart Settings 29, 30, 61

assignments 32 change notifications 34 creating 31 default 61 diagnostics 36 Fabric Connection 30 Initiator or Target 30 Initiator with Stealth 30 policies 33 port information 33 port recovery 35 pre-insertion testing 33 String Cascade 30 Target with Stealth 30 Tree Cascade 30

SNMP traps 25 speed, operating 24 String Cascade Smart Setting 30 string cascades 45 switch

cascades 45 changing the password 27 configuration 22 configuration files 37, 38 date and time settings 26 default Smart Settings 61 event log 52 event log messages 68 features 2 firmware 37 general settings 23 hard zoning 44 identification 23 initial setup 19 installation 6, 7

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE INDEX

EMULEX CORPORATION 74 PART NUMBER 00041392-002 REV. B

LEDs 9 load balancing 47 management 15, 21 monitoring 49 network settings 23 operating conditions 64 ordered sets 57 overview 1 package contents 6 policies 33, 34, 35, 36 port diagnostics 55 port information 53 port utilization 54 powering on 13 settings 22 specifications 64 speed 24 status 49 telnet session 27 thresholds 28 trunking 46 unpacking 6 version 24 Web Manager login 22 zoning 39, 40, 41, 42

system LEDs 10

T Target with Stealth Smart Setting 30 telnet session 27 temperature 64 terms

see glossary 71 thresholds 28 time and date settings 26 traps 25 Tree Cascade Smart Setting 30 tree cascades 45 troubleshooting 59 trunking 46

U UL guidelines 7 unpacking the switch 6

V version information 24 viewing

event log 52 ordered sets 57 port diagnostics 55 port information 53 port utilization 54 switch status 49

W Web Manager 15

agent up time 24 automatic trunking 46 Bad Zone Recovery 43 configuration 17 configuration files 37, 38 event log 52 firmware 37 getting started 16 hard zoning 44 initial switch setup 19 load balancing 47 loading firmware 37 network location 23 network settings 23 opening a telnet session 27 ordered sets 57 overview 17 password 27 port diagnostics 55 port information 53 port utilization 54 Smart Settings 29 SNMP traps 25 switch identification 23 switch login 22 switch speed 24 switch status 49 switch thresholds 28 switch version 24 time settings 26 zoning 39, 40, 41, 42

Z Zone Initialization Master 40 zoning 39

bad zone recovery 43 hard zoning 44 Initialization Master 40 multiple switches 42 ports in multiple zones 41 single switch 40 using AL_PAs 4

Manualsnet FAQs

If you want to find out how the EMULEX Apple works, you can view and download the Apple EMULEX Model 375 User's Guide on the Manualsnet website.

Yes, we have the User's Guide for Apple EMULEX as well as other Apple manuals. All you need to do is to use our search bar and find the user manual that you are looking for.

The User's Guide should include all the details that are needed to use a Apple EMULEX. Full manuals and user guide PDFs can be downloaded from Manualsnet.com.

The best way to navigate the Apple EMULEX Model 375 User's Guide is by checking the Table of Contents at the top of the page where available. This allows you to navigate a manual by jumping to the section you are looking for.

This Apple EMULEX Model 375 User's Guide consists of sections like Table of Contents, to name a few. For easier navigation, use the Table of Contents in the upper left corner.

You can download Apple EMULEX Model 375 User's Guide free of charge simply by clicking the “download” button in the upper right corner of any manuals page. This feature allows you to download any manual in a couple of seconds and is generally in PDF format. You can also save a manual for later by adding it to your saved documents in the user profile.

To be able to print Apple EMULEX Model 375 User's Guide, simply download the document to your computer. Once downloaded, open the PDF file and print the Apple EMULEX Model 375 User's Guide as you would any other document. This can usually be achieved by clicking on “File” and then “Print” from the menu bar.